Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
J Chromatogr Sci ; 58(9): 814-822, 2020 Sep 29.
Article in English | MEDLINE | ID: mdl-32794561

ABSTRACT

A sensitive, selective, accurate and precise ultra-high performance liquid chromatography-Tandem mass spectrometry (MS/MS) method was developed and validated for the simultaneous determination of drugs used as eye drops in cataract surgery in aqueous humor. Cataract surgery requires a powerful mydriatic eye drops combination such as cyclopentolate hydrochloride and phenylephrine hydrochloride to dilate the pupil and facilitate eye lens replacement and also requires strong fluoroquinolone antibiotic such as lomefloxacin hydrochloride. The method was performed with positive ion electrospray ionization and the analytes were quantified and monitored on a triple quadrupole mass spectrometer using multiple reaction monitoring scanning mode. Liquid-liquid extraction was used for the purification and preconcentration of analytes from rabbit aqueous humor matrix. Chromatographic elution was performed using an Phenomenex Luna® C18 (150 mm × 2.1 mm, 1.6 µm) column and moxifloxacin hydrochloride as internal standard with a mobile phase consisting of methanol:water:formic acid (70:29:1, by volume) at flow rate of 0.2 mL/min. Satisfactory results regarding linearity, recovery, stability, accuracy and precision of the analytes were obtained. Full validation of the procedure was performed according to the US Food and Drug Administration guidance for industry: bioanalytical method validation and European Medicines Agency (EMA) guideline on bioanalytical method validation.


Subject(s)
Aqueous Humor/chemistry , Chromatography, High Pressure Liquid/methods , Ophthalmic Solutions/analysis , Ophthalmic Solutions/chemistry , Tandem Mass Spectrometry/methods , Animals , Cataract Extraction , Cyclopentolate/analysis , Female , Fluoroquinolones/analysis , Limit of Detection , Linear Models , Male , Phenylephrine/analysis , Rabbits , Reproducibility of Results
2.
J AOAC Int ; 100(2): 434-444, 2017 Mar 01.
Article in English | MEDLINE | ID: mdl-28118561

ABSTRACT

Two sensitive, selective, and precise stability-indicating methods have been developed for the simultaneous determination of the active pharmaceutical ingredients cyclopentolate hydrochloride (CLO) and phenylephrine hydrochloride (PHE) in their pure forms and in the presence of their degradation products. The methods were applied for the determination of CLO and PHE in a pharmaceutical formulation. Method A was based on isocratic elution HPLC determination. Separation was achieved using a Waters Spherisorb ODS2 C18 analytical column (5 µm particle size) and a mobile phase of 0.1% heptane-1-sulphonic acid sodium salt in methanol-water (80 + 20, v/v). The flow rate was 1.0 mL/min and detection was performed at 210 nm. Method B was an HPTLC- densitometric method using HPTLC silica gel 60 F254 plates and an optimized mobile phase of ethyl acetate-methanol-ammonia (8 + 2 + 0.1, v/v/v). The separated spots were densitometrically scanned at 210 nm. Polynomial equations were used for regression. The developed methods are suitable for the determination of CLO and PHE in their binary mixture and in the presence of their corresponding degradation products. The two methods were validated in compliance with International Conference on Harmonization guidelines and successfully applied for the determination of CLO and PHE as synthetically prepared in laboratory mixtures and in the presence of their possible degradation products. CLO alkaline degradation products were stated as potential impurities in British Pharmacopoeia. The degradation products were separated and identified by mass spectra. Postulation of a PHE oxidative degradation pathway was suggested. The obtained results were statistically analyzed and compared with those obtained by applying the official methods for both drugs.


Subject(s)
Cyclopentolate/analysis , Phenylephrine/analysis , Chromatography, High Pressure Liquid , Chromatography, Thin Layer , Cyclopentolate/chemistry , Densitometry , Hydrogen Peroxide/chemistry , Models, Chemical , Ophthalmic Solutions , Oxidation-Reduction , Phenylephrine/chemistry , Sodium Hydroxide/chemistry
3.
Klin Monbl Augenheilkd ; 175(1): 100-2, 1979 Jul.
Article in German | MEDLINE | ID: mdl-491456

ABSTRACT

Symptoms of poisoning were noticed in a eight-year-old boy after prescribed application of cyclopentolate 1 per cent (as declared by manufacturing firm). Acute psychosis disappeared spontaneous 3,5 hours later. Pharmacological analysis of the eye-drops showed that concentration of active agent wasn't 1 per cent but 1.31 per cent.


Subject(s)
Cyclopentolate/adverse effects , Mydriatics/adverse effects , Phenylacetates/adverse effects , Psychoses, Substance-Induced/etiology , Child , Cyclopentolate/analysis , Humans , Male , Mydriatics/analysis , Refractive Errors/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL
...