Results 1 - 20 de 5.964
Filter
1.
Dent Med Probl ; 61(3): 391-399, 2024.
Article in English | MEDLINE | ID: mdl-38963395

ABSTRACT

BACKGROUND: In Mexico and around the world, water in dental units, including triple syringes, comes from municipal chlorinated water mains. The microbial contamination of dental unit water systems constitutes a risk factor for opportunistic infections. OBJECTIVES: The present work aimed to identify the bacteria present in the triple-syringe water lines of dental units at a dental school of a public university in Mexico, with a hypothesis that opportunistic bacteria of importance to human health would be found. MATERIAL AND METHODS: A cross-sectional study was carried-out. A total of 100 samples of triple-syringe tubing from dental units operated by a dental school of a public university in Mexico were analyzed before and after their use in dental practice. Bacterial biofilm was cultured and isolated from the tubing, using standard microbiological methods, and then the species present were identified through 16S rRNA gene sequencing. The characterization of the biofilm was performed by means of scanning electron microscopy (SEM). RESULTS: Bacterial growth was observed in 20% of the non-disinfected and 10% of the disinfected samples, with 11 strains isolated. Six genera and 11 bacterial species were genetically identified. Coagulasenegative staphylococci (CoNS), considered opportunistic human pathogens, were among the most critical microorganisms. Scanning electron microscopy revealed a thick polymeric matrix with multiple bacterial aggregates. CONCLUSIONS: Opportunistic bacteria from human skin and mucous membranes were detected. Under normal conditions, these bacteria are incapable of causing disease, but are potentially harmful to immunosuppressed patients.


Subject(s)
Biofilms , Equipment Contamination , Syringes , Water Microbiology , Cross-Sectional Studies , Mexico , Humans , Syringes/microbiology , Dental Equipment/microbiology , Microscopy, Electron, Scanning , Bacteria/isolation & purification , Genotype , RNA, Ribosomal, 16S
2.
Br Dent J ; 236(11): 917, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38877264
3.
BMC Oral Health ; 24(1): 648, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38824549

ABSTRACT

BACKGROUND: Ensuring the safety of dental unit waterlines (DUWLs) has become a pivotal issue in dental care practices, focusing on the health implications for both patients and healthcare providers. The inherent structure and usage conditions of DUWLs contribute to the risk of biofilm formation and bacterial growth, highlighting the need for effective disinfection solutions.The quest for a disinfection method that is both safe for clinical use and effective against pathogens such as Staphylococcus aureus and Escherichia coli in DUWLs underscores the urgency of this research. MATERIALS: Chlorine dioxide disinfectants at concentrations of 5, 20, and 80 mg/L were used to treat biofilms of S. aureus and E. coli cultured in DUWLs. The disinfection effectiveness was assessed through bacterial counts and culturing. Simultaneously, human skin fibroblast cells were treated with the disinfectant to observe changes in cell morphology and cytotoxicity. Additionally, the study included corrosion tests on various metals (carbon steel, brass, stainless steel, aluminum, etc.). RESULTS: Experimental results showed that chlorine dioxide disinfectants at concentrations of 20 mg/L and 80 mg/L significantly reduced the bacterial count of S. aureus and E. coli, indicating effective disinfection. In terms of cytotoxicity, higher concentrations were more harmful to cellular safety, but even at 80 mg/L, the cytotoxicity of chlorine dioxide remained within controllable limits. Corrosion tests revealed that chlorine dioxide disinfectants had a certain corrosive effect on carbon steel and brass, and the degree of corrosion increased with the concentration of the disinfectant. CONCLUSION: After thorough research, we recommend using chlorine dioxide disinfectant at a concentration of 20 mg/L for significantly reducing bacterial biofilms in dental unit waterlines (DUWLs). This concentration also ensures satisfactory cell safety and metal corrosion resistance.


Subject(s)
Biofilms , Chlorine Compounds , Dental Equipment , Disinfection , Escherichia coli , Oxides , Staphylococcus aureus , Chlorine Compounds/pharmacology , Oxides/pharmacology , Biofilms/drug effects , Escherichia coli/drug effects , Humans , Staphylococcus aureus/drug effects , Disinfection/methods , Dental Equipment/microbiology , Disinfectants/pharmacology , Dental Disinfectants/pharmacology , Fibroblasts/drug effects , Bacterial Load/drug effects , In Vitro Techniques
4.
J Am Dent Assoc ; 155(6): 515-525.e1, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38839239

ABSTRACT

BACKGROUND: Dental unit waterline (DWL) infection control is critical to infection prevention. Identifying challenges and barriers to its implementation is a first step toward understanding how to improve engagement. METHODS: A survey was distributed to dentists, dental hygienists, and dental assistants via the Qualtrics XM platform (Qualtrics). Responses were analyzed to quantify engagement in practices contrary to Centers for Disease Control and Prevention guidance and identify avenues to improve engagement. RESULTS: Although oral health care providers recognized DWL infection control was important, there was a lack of clarity about appropriate routine engagement (eg, what lines should be tested), what should be noted in practice infection control records, and steps to be taken in response to a failed test result (ie, ≥ 500 colony-forming units/mL), such as taking a chair out of service. CONCLUSIONS: Survey results showed there were considerable gaps in knowledge and practice that could lead to patient harm. Oral health care provider training may not prepare personnel adequately to engage in, let alone supervise, DWL infection control. DWL infection control, like other aspects of infection control, requires action informed via an understanding of what needs to be done. Although good intentions are appreciated, better approaches to DWL infection control information dissemination and strategies to engage dental assistants, dental hygienists, and dentists in best practices are needed. PRACTICAL IMPLICATIONS: Evolving standards of care, including infection control, should be reflected in the provision of dental treatment. Improvements in communicating and ensuring engagement in best practices are needed when it comes to DWL infection control.


Subject(s)
Infection Control, Dental , Humans , Infection Control, Dental/methods , Dental Hygienists , Surveys and Questionnaires , Dentists , Dental Equipment , Equipment Contamination/prevention & control , Health Knowledge, Attitudes, Practice , Dental Assistants
5.
Indian J Dent Res ; 35(1): 80-83, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38934755

ABSTRACT

BACKGROUND: Dental Unit Water Line (DUWL) deliver water to different handpieces in a dental unit. The water in DUWL circulates in a closed system, where it is taken from a container. The quality of dental water is of considerable importance since patients and dental staff are regularly exposed to water and aerosols generated from dental equipment. Output water from DUWLs may be a potential source of infection for both dental health care personnel and patients. AIM: To assess the microbial contamination in the DUWL among dental clinics in Chennai. MATERIALS AND METHODS: An in vitro study was conducted on 60 water samples from 20 dental clinics in Chennai in December 2019. Water samples were collected from three different sources of the Dental unit according to ADA guidelines. The collected samples were assessed for the presence of Aspergillus, Acinetobacter, Pseudomonas aeruginosa, and Legionella by agar plate method. The data were analysed using SPSS software version 20. RESULTS: Legionella was the most prevalent microorganism with 70% prevalence in a three-way syringe and 50% in scaler and airotor, followed by Pseudomonas aeruginosa and Acinetobacter with 10% prevalence in scaler and airotor and Aspergillus with a prevalence of 10% in the three-way syringe. CONCLUSION: Most of the dental units were contaminated with Aspergillus, Legionella, Pseudomonas aeruginosa and Acinetobacter which pose a serious threat to the patients as well as the dentists.


Subject(s)
Dental Clinics , Dental Equipment , Equipment Contamination , Legionella , Water Microbiology , India , Dental Equipment/microbiology , Humans , Legionella/isolation & purification , Pseudomonas aeruginosa/isolation & purification , Acinetobacter/isolation & purification , In Vitro Techniques
6.
Microbiol Spectr ; 12(6): e0396223, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38652098

ABSTRACT

Water contamination in dental unit waterlines (DUWLs) is a potential source of healthcare-associated infection during dental care. The aim of this study was to evaluate the microbiological quality of DUWLs water from newly installed dental chairs in a French University Hospital. The microbiological quality of water from 24 new DUWLs initially disinfected by ICX Renew-prior to use of the dental units for patient treatment-was assessed for total culturable aerobic bacteria at 22°C and 36°C, Legionella sp., Pseudomonas aeruginosa, and total coliforms. Among the 24 samples analyzed, 21 were compliant with the water quality levels: 19 had no bacteria, and 2 contained only 4 and 1 CFU/mL for total culturable aerobic bacteria at 22°C and 36°C, respectively. Three samples were non-compliant due to contamination by P. aeruginosa (4, 2, and 2 CFU/100 mL). Controlling and preventing the microbiological contamination of DUWLs, especially by pathogenic bacteria, at the time of the installation of the new dental chairs are crucial to prevent healthcare-associated infection in dentistry. IMPORTANCE: Dental unit waterlines (DUWLs) of new dental chairs may be contaminated before their first clinical use, so an initial shock disinfection is crucial at the time of their installation. The microbiological analyses are crucial to control the water quality of DUWLs before their first clinical use because their disinfection does not guarantee the elimination of all bacteria.


Subject(s)
Pseudomonas aeruginosa , Water Microbiology , Pseudomonas aeruginosa/isolation & purification , Humans , Disinfection/methods , Dental Equipment/microbiology , Equipment Contamination , Cross Infection/microbiology , Cross Infection/prevention & control , France , Legionella/isolation & purification
7.
Br Dent J ; 236(6): 492, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38519692
8.
BMC Oral Health ; 23(1): 865, 2023 11 14.
Article in English | MEDLINE | ID: mdl-37964280

ABSTRACT

BACKGROUND: In dentistry, nosocomial infection poses a great challenge to clinicians. The microbial contamination of water in dental unit waterlines (DUWLs) is ubiquitous. Such infected DUWLs can transmit oral microbes in the form of aerosols. Previous studies have suggested treating DUWLs with various disinfectants to reduce cross-contamination. The literature lacks a comparative evaluation of the effect of the use of 0.2% chlorhexidine (CHX) and 0.1% sodium hypochlorite (NaOCl) in DUWLs on aerosolized bacteria generated during dental procedures. OBJECTIVE: To compare the effect of NaOCl and CHX in DUWLs on aerosolized bacteria generated during restorative and endodontic procedures. MATERIALS AND METHODS: A total of 132 patients were equally divided into three groups (n = 44 in each group) according to the content of DUWL as follows. Group I-0.1% NaOCl Group II-0.2% CHX Group III-distilled water (Positive control) One-way ANOVA was performed and the Kruskal-Wallis test was used for intergroup comparison. RESULTS: For the restorative procedure, inter-group comparison of mean colony-forming units (CFU) scores showed a statistically significant difference between the groups (p - .001) with the score of group 3 higher than group 2 followed by group 1. For the endodontics, an inter-group comparison of CFU scores showed a statistically significant difference between the groups (p - .003) with the mean score in group 1 being the lowest and group 3 being the highest. CONCLUSION: The addition of NaOCl or CHX in DUWLs shows an effective reduction in aerosolized bacteria compared to distilled water.


Subject(s)
Chlorhexidine , Sodium Hypochlorite , Humans , Bacteria , Chlorhexidine/pharmacology , Chlorhexidine/therapeutic use , Colony Count, Microbial , Dental Care , Dental Equipment/microbiology , Sodium Hypochlorite/pharmacology , Water/pharmacology
9.
BMC Oral Health ; 23(1): 867, 2023 11 15.
Article in English | MEDLINE | ID: mdl-37968643

ABSTRACT

OBJECTIVES: This retrospective study examined the dental unit waterline (DUWL) testing practices of Saskatchewan dental clinics over a period of 11 years, with an emphasis on their responses after identification of high microbial levels. MATERIALS AND METHODS: Dental clinics (n = 137) aseptically collected samples of output water from their air/water syringes, handpieces, and ultrasonic scaler lines using Sigma-Aldrich® waterline test kits and delivered them to a quality assurance laboratory. Tests were incubated for seven days at room temperature, and those with heterotrophic plate counts > 500 CFU/mL were reported as failures. Statistical analyses were performed on a database containing 4,093 test results. RESULTS: Participating clinics submitted an average of 11 DUWL tests per year. Overall, 21% of tests failed, and a moderate positive association (rs=.52, p < 0.001) was found between clinics' DUWL testing frequency and failure rate. Only 7% of failed DUWL tests were followed up by collection of a subsequent test within two weeks, of which 47% still exceeded the 500 CFU/mL threshold. CONCLUSIONS: Our findings demonstrate an association between DUWL testing frequency and detection of unacceptable microbial levels, along with infrequent retesting and often-inadequate intervention after a failed test. This suggests the need for further efforts at the regulatory and educational levels to maintain adequate water quality during dental treatment. CLINICAL RELEVANCE: Procedural water can become contaminated in DUWLs and endanger patients. Regular DUWL monitoring and evidence-based interventions to treat contaminated systems are necessary to safeguard patient health.


Subject(s)
Biofilms , Dental Equipment , Humans , Retrospective Studies , Colony Count, Microbial , Equipment Contamination
10.
Rev. ADM ; 80(5): 267-273, sept.-oct. 2023.
Article in Spanish | LILACS | ID: biblio-1531449

ABSTRACT

El propósito del presente trabajo está orientado a generar una reflexión entre el gremio odontológico profesional y los estudiantes de las licenciaturas en Odontología respecto a la contaminación global que estamos generando y a la crítica situación del planeta, así como sus consecuencias ambientales y climatológicas, sobre lo importante que es educar bajo la perspectiva de una Odontología Verde y Sostenible a través de la ambientalización curricular en las escuelas y facultades de Odontología para generar un tipo de cultura y conciencia proambiental. De igual forma para señalar lo sencillo que es ambientalizar agradable y relajantemente nuestro entorno educativo y laboral, así como realizar algunas prácticas odontológicas ecológicas y ambientales en la práctica privada que cuestan poco o nada y que, por el contrario, el gran efecto positivo que éstas tendrán en el medio ambiente y la reducción de los niveles de contaminación actuales. Si realmente logramos generar una nueva cultura y conciencia que se preocupe por el medio ambiente en el campo de la Odontología, los resultados para todos se verán reflejados en un mejor ambiente social, educativo de trabajo y de salud (AU)


The purpose of this work is aimed at generating a reflection between the professional dental guild and the students of the Bachelor's Degrees in Dentistry regarding the global pollution that we are generating and the critical situation of the planet and its environmental and climatological consequences, on how important it is educate under the perspective of a Green and Sustainable Dentistry through the greening of the curriculum in the Schools and Faculties of Dentistry to generate a type of culture and pro-environmental awareness. Likewise, point out how simple it is to pleasantly and relaxingly green our educational and work environment, as well as perform some ecological and environment, as well perform some ecological and environment, dental practices in private practice that cost little or nothing and that, on the contrary, the great positive effect that these will have on the environment and the reduction of current pollution levels. If we truly manage to generate a new culture and awareness that cares about the environment in the field of Dentistry, the results for all will be reflected in a better social, educational, work and health environment (AU)


Subject(s)
Dentistry/trends , Environment , Environmental Pollution/prevention & control , Awareness , Climate Change , Dental Equipment/trends , Sustainable Development Indicators
12.
Salud mil ; 42(2): e402, 20230929. tab
Article in Spanish | LILACS, UY-BNMED, BNUY | ID: biblio-1531709

ABSTRACT

A partir de la declaración de la Organización Mundial de la Salud del comienzo de la pandemia COVID-19 causada por el virus SARS-CoV-2 en marzo de 2020, los profesionales de la salud se vieron expuestos a esta enfermedad altamente contagiosa y potencialmente mortal que generó múltiples desafíos a toda la comunidad científica. Provocando cambios de paradigmas en la atención de los pacientes y en el uso de las barreras de protección personal. A nivel mundial se crearon múltiples protocolos para la atención odontológica a medida que se iba desarrollando e investigando el comportamiento del virus. Esta revisión bibliográfica resume las indicaciones y recomendaciones basadas en las evidencias disponibles para disminuir las posibilidades de contaminación ante la exposición a este virus, incluyendo medidas a utilizar desde el ingreso del paciente, los métodos de protección personal, la descontaminación y esterilización del material, así como también la desinfección del área de trabajo. Aunque se ha hecho un gran esfuerzo por mejorar los procesos de bioseguridad a nivel científico tecnológico, hay evidencias de que el factor humano sigue siendo el eslabón más débil de esta cadena.


Since the declaration by the World Health Organization of the beginning of the COVID-19 pandemic caused by the SARS-CoV-2 virus in March 2020, health professionals were exposed to this highly contagious and potentially fatal disease that generated multiple challenges to the entire scientific community. It caused paradigm shifts in patient care and in the use of personal protective barriers. Multiple protocols for dental care were created worldwide as the behavior of the virus was developed and investigated. This bibliographic review summarizes the indications and recommendations based on the available evidence to reduce the possibilities of contamination when exposed to this virus, including measures to be used from patient admission, personal protection methods, decontamination and sterilization of material, as well as disinfection of the work area. Although a great effort has been made to improve biosafety processes at the scientific and technological level, there is evidence that the human factor continues to be the weakest link in this chain.


Desde a declaração pela Organização Mundial da Saúde do início da pandemia de COVID-19 causada pelo vírus SARS-CoV-2 em março de 2020, os profissionais de saúde foram expostos a essa doença altamente contagiosa e potencialmente fatal, que criou vários desafios para toda a comunidade científica. Ela causou mudanças de paradigma no atendimento ao paciente e no uso de barreiras de proteção individual. Em todo o mundo, vários protocolos para atendimento odontológico foram criados à medida que o comportamento do vírus foi desenvolvido e pesquisado. Esta revisão da literatura resume as indicações e recomendações baseadas em evidências para reduzir a probabilidade de contaminação por exposição a esse vírus, incluindo medidas a serem usadas desde a admissão do paciente, métodos de proteção individual, descontaminação e esterilização de equipamentos, bem como desinfecção da área de trabalho. Embora muitos esforços tenham sido feitos para melhorar os processos de biossegurança em nível científico e tecnológico, há evidências de que o fator humano continua sendo o elo mais fraco dessa cadeia.


Subject(s)
Humans , Sterilization/instrumentation , Disinfection/instrumentation , Dental Equipment , Dental Offices , COVID-19/prevention & control
13.
PeerJ ; 11: e15830, 2023.
Article in English | MEDLINE | ID: mdl-37576504

ABSTRACT

Background: This study compared the ability of thermally treated files in shaping simulated canals with double curvature. Fifty-six canals were enlarged to a final size of 25 with ProTaper Next (PTN) or ZenFlex (ZF). Materials: Half of the samples were shaped with cooled files (n = 14 each). The amount of removed resin was measured and canal deviation was determined at eight levels. Shaping time and maximum shaping torque values were also recorded. Data were statistically analyzed using analysis of variance and LSD, Kruskal-Wallis, and chi-square tests at a 0.05 significance level. Results: Compared to PTN and cooled PTN, ZF and cooled ZF required lesser time to shape the canals. The maximum torques were found comparable between the groups. All the groups generated negligible deviations at every canal level evaluated and maintained the canal geometry. Although not significant, the cooled PTN and ZF files exhibited lesser canal deviations than their counterparts. Conclusion: All groups demonstrated similar shaping ability whilst maintaining the original curvature of the canal in simulated canals with double curvature. However, ZF groups were able to shape the canals faster than PTN groups. There was a trend that cooled files made lesser canal deviations compared to their counterparts.


Subject(s)
Cold Temperature , Dental Equipment , Root Canal Preparation , Equipment Design , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Root Canal Preparation/standards , Torque , Analysis of Variance , Dental Equipment/standards
14.
Rev. ADM ; 80(4): 204-208, jul.-ago. 2023. ilus, tab
Article in Spanish | LILACS | ID: biblio-1526314

ABSTRACT

Objetivo: disminuir el efecto de artefacto que generan objetos de alta densidad mediante la utilización de filtros de distintos materiales y espesores, ubicados en lugares estratégicos del tomógrafo. Material y métodos: se utilizaron filtros de aluminio y de cobre ubicados en lugares estratégicos en el equipo tomográfico. Se realizaron cortes oblicuos en piezas dentarias con restauraciones metálicas y en implantes; se midió la extensión del artefacto en ancho y alto en cada adquisición tomográfica. Resultados: se hallaron diferencias significativas respecto a la disminución de la dispersión de acuerdo con cada filtro con respecto a la no utilización de estos elementos. Conclusión: la utilización de filtros logró disminuir el efecto de artefacto en estructuras de alta densidad, obteniendo una mejor calidad de imagen para el diagnóstico, permitiendo que el software pueda reconstruir una imagen real (AU)


Objective: to diminish the artifact effect generated by high density objects by using filters of different materials and thickness, located in strategic places of the tomograph. Material and methods: aluminum and copper filters located in strategic places in the tomographic equipment were used. Oblique cuts were made on dental pieces with metal restorations and implants; the extension of the artifact in width and height was measured in each tomographic acquisition. Results: significant differences were found regarding the decrease of the dispersion according to each filter with respect to the non-use of these elements. Conclusion: the use of filters achieves to diminish the artifact effect in structures of high density, obtaining a better image quality for the diagnosis, allowing the software to reconstruct a real image (AU)


Subject(s)
Artifacts , Dental Equipment , Cone-Beam Computed Tomography , Dental Implants , Filters , Aluminum
15.
BMC Oral Health ; 23(1): 158, 2023 03 18.
Article in English | MEDLINE | ID: mdl-36934281

ABSTRACT

BACKGROUNDS: Numerous studies have shown that dental unit water lines (DUWLs) are often contaminated by a wide range of micro-organisms (bacteria, fungi, protozoa) and various prevalence have been reported for it in previous studies. Therefore, this review study aims to describe the prevalence of bacterial biofilm contamination of DUWLs. METHODS: This is a systematic review and meta-analysis in which the related keywords in different international databases, including Medline (via PubMed) and Scopus were searched. The retrieved studies were screened and the required data were extracted from the included studies. Three standard methods including American Dental Association (ADA), The Center for Disease Control and Prevention (CDC) and contaminated > 100 CFU/ml(C-100) standards were used to assess the bacterial biofilm contamination of DUWLs. All studies that calculated the prevalence of bacterial biofilm contamination of DUWLs, and English full-text studies were included in the meta-analysis. Studies that did not have relevant data or used unusual laboratory methods were excluded. Methodological risk of bias was assessed by a related checklist and finally, the data were pooled by fixed or random-effect models. RESULTS: Seven hundred and thirty-six studies were identified and screened and 26 related studies were included in the meta-analysis. The oldest included study was published in 1976 and the most recent study was published in 2020. According to the ADA, CDC and C-100 standards, the prevalence of bacterial contamination was estimated to be 85.0% (95% confidence interval (CI): 66.0-94.0%), 77.0% (95%CI: 66.0-85.0%) and 69.0% (95%CI: 67.0-71.0%), respectively. The prevalence of Legionella Pneumophila and Pseudomonas Aeruginosa in DUWLs was estimated to be 12.0% (95%CI: 10.0-14.0%) and 8.0% (95%CI: 2.0-24.0%), respectively. CONCLUSION: The results of this review study suggested a high prevalence of bacterial biofilm in DUWLs; therefore, the use of appropriate disinfecting protocol is recommended to reduce the prevalence of contamination and reduce the probable cross-infection.


Subject(s)
Bacteria , Dental Equipment , Humans , Dental Equipment/microbiology , Prevalence , Biofilms , Equipment Contamination/prevention & control , Colony Count, Microbial
16.
Indian J Dent Res ; 34(3): 266-269, 2023.
Article in English | MEDLINE | ID: mdl-38197344

ABSTRACT

Aim: : The aim of this study was to measure the amount of material extruded in the periapical area using three irrigation needles (Max-I-Probe, NaviTip Fx and IrriFlex flexible needle). Materials and Methods: : Mandibular premolars were selected for this study and glass vials were used to gather the extruded debris and they were preweighed. The samples were divided into two groups: Group A (1 mm penetration of needle from working length), which was subdivided into three subgroups: Subgroup A1: Irrigation was made by Max-I-Probe. Subgroup A2: Irrigation was made by NaviTip Fx. Subgroup A3: Irrigation was made by IrriFlex flexible needle. Group B (3 mm penetration of needle), which was subdivided into three subgroups: Subgroup B1: Irrigation was made by Max-I-Probe. Subgroup B2: Irrigation was made by NaviTip Fx. Subgroup B3: Irrigation was made by IrriFlex flexible needle. XP-endo Shaper was used for chemomechanical preparation. After removal from vials, the teeth were incubated and then removed from the incubator and weighed again three times. The average of the readings was taken. Analysis of variance (ANOVA) and least significance difference tests were applied to analyse data. Results: : All of the needles caused debris extrusion. There was a significant difference between groups (P ≤ 0.001) according to the depth of penetration. The lowest value for debris was observed in subgroup B3 while subgroup A2 had shown the highest mean. Conclusion: Results revealed that the design and depth of needles significantly affected the debris extrusion. Using more flexible needles and shorter penetration depth for irrigation so that we don't need to push the needles so far apically.


Subject(s)
Dental Equipment , Equipment Design , Needles , Analysis of Variance , Therapeutic Irrigation
17.
Arq. odontol ; 59: 106-113, 2023. ilus
Article in English | LILACS, BBO - Dentistry | ID: biblio-1518971

ABSTRACT

Aim: The purpose of this study was to evaluate the efficacy to determine the root canal length, in vitro,of both the electronic apex locator (M2) and the autostop (AS - M3) functions of the Endus Duo Gnatus endodontic motor (Gnatus, São Paulo, SP, Brazil). Methods: Thirty extracted human single-rooted premolars had their root canal lengths (TLs) up to the apical foramen determined using the Endus Duo Gnatus in two ways: (1) In the stainless steel (SS) control group, the measurement was obtained using a stainless steel hand instrument with the electronic locator mode (M2 function) connected to a stainless-steel hand instrument (K-file #15). In the NiTi rotary instrument (NiTi RI) intervention group, the measurement was obtained during the instrumentation (M3 function) of the root canals with a nickel-titanium rotary instrument (Hyflex CM: Coltene Whaledent, Cuyahoga Falls, OH, USA), size 25/.06. The NiTi manually used instrument (NiTi MUI) Intervention group performed the measurement in locator mode using a Hyflex instrument, placed to true length manually. Statistical analysis was performed using ANOVA followed by the Tukey post-hoc test with a significance level of p < 0.05. Results: The true mean length and standard deviation (SD) of the standardized root canals were 18.40 ± 2.14mm, while the mean lengths and standard deviations (SD) were 18.29 ± 1.89mm, 18.22 ± 1.85mm, and 17.24 ± 2.09mm for the SS, NiTi RI, and NiTi MUI groups, respectively. However, data from the NiTi MUI Intervention group indicated shorter root canal lengths when compared to the SS control group and the NiTi RI Intervention group values, and were significantly shorter than the true canal length (p < 0.001). Conclusions:The use of the motor in NiTi RI Intervention group showed acceptable results. However, the NiTi MUI Intervention group resulted in unacceptable short measurements.


Objetivo: O objetivo deste estudo foi avaliar a eficácia na determinação do comprimento do canal radicular, in vitro, das funções localizador eletrônico foraminal (M2) e auto-parada durante a instrumentação (M3) do motor endodôntico Endus Duo Gnatus ( Gnatus, São Paulo, SP, Brasil). Métodos: Trinta pré-molares humanos uniradiculares extraídos tiveram seus comprimentos de canais radiculares (CRTs) até o forame apical determinados usando o Endus Duo Gnatus de duas maneiras: (1) No grupo controle de aço inoxidável (SS), a medida foi obtida usando um instrumento manual de aço inoxidável com modo de localização eletrônica foraminal (função M2) conectado a um instrumento manual de aço inoxidável (lima tipo K #15). No grupo intervenção instrumento rotatório NiTi (NiTi RI), a medida foi obtida durante a instrumentação (função M3) dos canais radiculares com instrumento rotatório de níquel-titânio (Hyflex CM: Coltene Whaledent, Cuyahoga Falls, OH, EUA), tamanho 25/.06. O grupo de intervenção NiTi instrumento usado manualmente (NiTi MUI) realizou a medição no modo localizador foraminal usando um instrumento Hyflex, colocado manualmente no comprimento real do dente. A análise estatística foi realizada por meio de ANOVA seguida do teste post-hoc de Tukey com nível de significância de p < 0,05. Resultados: Os comprimentos reais médios dos dentes e desvios-padrão (DP) dos canais radiculares padronizados foram 18,40 ± 2,14 mm, enquanto os comprimentos médios e desvios- padrão (DP) foram 18,29 ± 1,89 mm, 18,22 ± 1,85 mm e 17,24 ± 2,09 mm para os grupos SS, NiTi RI e NiTi MUI, respectivamente. No entanto, os dados do grupo de intervenção NiTi MUI indicaram comprimentos de canais radiculares mais curtos quando comparados aos valores do grupo controle SS e do grupo de intervenção NiTi RI, e foram significativamente mais curtos que o comprimento real do canal (p < 0,001). Conclusões: A utilização do motor no grupo Intervenção NiTi RI apresentou resultados aceitáveis. No entanto, o grupo de intervenção NiTi MUI resultou em medições curtas inaceitáveis.


Subject(s)
Weights and Measures , Dental Equipment , Dental Pulp Cavity , Endodontics
18.
Article in English | MEDLINE | ID: mdl-36078275

ABSTRACT

In dental clinics, the infections may be acquired through contaminated devices, air, and water. Aerosolized water may contain bacteria, grown into the biofilm of dental unit waterlines (DUWLs). We evaluated a disinfection method based on water osmosis and chlorination with chlorine dioxide (O-CD), applied to DUWL of five dental clinics. Municipal water was chlorinated with O-CD device before feeding all DUWLs. Samplings were performed on water/air samples in order to research total microbial counts at 22-37 °C, Pseudomonas aeruginosa, Legionella spp., and chlorine values. Water was collected from the taps, spittoons, and air/water syringes. Air was sampled before, during, and after 15 min of aerosolizing procedure. Legionella and P. aeruginosa resulted as absent in all water samples, which presented total microbial counts almost always at 0 CFU/mL. Mean values of total chlorine ranged from 0.18-0.23 mg/L. Air samples resulted as free from Legionella spp. and Pseudomonas aeruginosa. Total microbial counts decreased from the pre-aerosolizing (mean 2.1 × 102 CFU/m3) to the post-aerosolizing samples (mean 1.5 × 10 CFU/m3), while chlorine values increased from 0 to 0.06 mg/L. O-CD resulted as effective against the biofilm formation in DUWLs. The presence of residual activity of chlorine dioxide also allowed the bacteria reduction from air, at least at one meter from the aerosolizing source.


Subject(s)
Disinfection , Legionella , Bacteria , Biofilms , Chlorine/pharmacology , Chlorine Compounds , Colony Count, Microbial , Dental Equipment , Disinfection/methods , Equipment Contamination/prevention & control , Osmosis , Oxides , Pseudomonas aeruginosa , Water , Water Microbiology
19.
Biofouling ; 38(6): 628-642, 2022 07.
Article in English | MEDLINE | ID: mdl-35924695

ABSTRACT

Biosafety in dentistry aims to combat cross-contamination and biofilm in dental unit waterlines. The aim was to investigate from a physical, chemical, mechanical and biological perspective, a protocol for using chemical products (citric acid, sodium bicarbonate and sodium chloride) to improve and maintain water quality in dental unit waterlines. Change in microhardness and corrosion tendency were observed in stainless steel samples. On the polyurethane surfaces, there were changes in color, microhardness and roughness. Anti-biofilm evaluations revealed a significant reduction in the biofilm biomass, metabolic activity and residual biofilm. These findings suggest that the protocol analyzed in this study showed an innovative potential against biofilm in dental unit waterlines, preserving the physical, chemical and mechanical properties of the materials.


Subject(s)
Biofilms , Equipment Contamination , Colony Count, Microbial , Corrosion , Dental Equipment , Water Microbiology
20.
J Dent Res ; 101(10): 1198-1204, 2022 09.
Article in English | MEDLINE | ID: mdl-35492016

ABSTRACT

Oral microbes are dispersed during dental treatment and reduction methods have been proposed, but dental unit waterline (DUWL) disinfectants have received little attention; specifically, the effect on viruses has not been studied. This study aims to 1) investigate the effect of DUWL disinfectants on viral dispersion in dental bioaerosols and 2) establish a dual-tracer system using live bacteriophage and fluorescein supported by optical particle measurement. Bacteriophage MS2 was used as a viral tracer and fluorescein as a fluorescent tracer. Validation experiments were conducted to exclude interference of one tracer with the other or of DUWL disinfectants on detection methods. Simulated "saliva" containing the tracers was infused into the mouth of a dental mannequin during 10-min dental procedures with an air turbine handpiece (n = 3 replicates). Aerosols and droplets were sampled in an enclosed dental operatory using air samplers and settlement onto sterile filter papers. Bacteriophage was quantified using plaque assays and reverse transcription quantitative polymerase chain reaction (RT-qPCR). Fluorescein was quantified fluorometrically. The effect of DUWL disinfectants on total aerosol concentration was assessed in separate experiments using an optical particle counter. DUWL disinfectants reduced bacteriophage viability, and interference between tracers was not observed. In simulated clinical procedures, the disinfectant ICX reduced bacteriophage detection substantially (P < 0.001; 2-way analysis of variance). MS2 RNA was detected in all experimental samples but not negative controls. Samples positive on RT-qPCR but not plaque assays may indicate that virions at distant sites are nonviable. Fluorescein tracer showed good agreement with the bacteriophage tracer. DUWL disinfectants designed for continuous presence in irrigants reduce the dispersion of viable virus in dental bioaerosols during simulated procedures. Their use may therefore be important for routine infection control and as a mitigation factor during infectious disease outbreaks. Future studies should explore this using a range of viruses and other microbes.


Subject(s)
Disinfectants , Aerosols/analysis , Dental Disinfectants/pharmacology , Dental Disinfectants/therapeutic use , Dental Equipment , Disinfectants/pharmacology , Fluoresceins
SELECTION OF CITATIONS
SEARCH DETAIL
...