Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 9.400
1.
Sci Rep ; 14(1): 12651, 2024 06 02.
Article En | MEDLINE | ID: mdl-38825618

Effective disinfection methods are crucial in the cold chain transportation process of food due to the specificity of temperature and the diversity of contaminated flora. The objective of this study was to investigate the sanitizing effect of different disinfectants on various fungi at - 20 °C to achieve accurate disinfection of diverse bacterial populations. Peracetic acid, hydrogen peroxide, and potassium bisulfate were selected as low-temperature disinfectants and were combined with antifreeze. The sanitizing effect of these cryogenic disinfectants on pathogens such as Bacillus subtilis black variant spores (ATCC9372), Staphylococcus aureus (ATCC 6538), Candida albicans (ATCC 10231), Escherichia coli (8099), and poliovirus (PV-1) was sequentially verified by bactericidal and virus inactivation experiments. After a specified time of disinfection, a neutralizing agent was used to halt the sanitizing process. The study demonstrates that different disinfectants exhibit selective effects during the low-temperature disinfection process. Peracetic acid, hydrogen peroxide, and potassium monopersulfate are suitable for the low-temperature environmental disinfection of bacterial propagules, viruses, and fungal contaminants. However, for microorganisms with strong resistance to spores, a low-temperature disinfectant based on peracetic acid should be chosen for effective disinfection treatment. Our results provide a valuable reference for selecting appropriate disinfectants to sanitize various potential pathogens in the future.


Cold Temperature , Disinfectants , Disinfection , Hydrogen Peroxide , Peracetic Acid , Disinfectants/pharmacology , Disinfection/methods , Hydrogen Peroxide/pharmacology , Peracetic Acid/pharmacology , Sulfates/pharmacology , Bacillus subtilis/drug effects , Potassium Compounds/pharmacology , Staphylococcus aureus/drug effects , Candida albicans/drug effects , Escherichia coli/drug effects , Poliovirus/drug effects
2.
Mikrochim Acta ; 191(6): 361, 2024 06 01.
Article En | MEDLINE | ID: mdl-38822891

A one-shot CO2 laser-based strategy to generate conductive reduced graphene oxide (rGO) decorated with nanoceria (nCe) is proposed. The 2D/0D rGO-nCe films, integrated as catalytic sensing layers in paper-based sensors, were employed for on-site monitoring of indoor fogging treatments against Listeria monocytogenes (Lm), a ubiquitous pathogenic bacterium. The rGO-nCe laser-assisted synthesis was optimized to preserve the rGO film morphological and electron-transfer features and simultaneously integrate catalytic nCe. The films were characterized by microscopical (SEM), spectroscopical (EDX, Raman, and FTIR), and electrochemical techniques. The most performing film was integrated into a nitrocellulose substrate, and the complete sensor was assembled via a combination of xurography and stencil printing. The rGO-nCe sensor's catalytic activity was proved toward the detection of H2O2, obtaining sensitive determination (LOD = 0.3 µM) and an extended linear range (0.5-1500 µM). Eventually, the rGO-nCe sensor was challenged for the real-time continuous monitoring of hydrogen peroxide aerosol during no-touch fogging treatment conducted following the EU's recommendation for biocidal product use. Treatment effectiveness was proved toward three Lm strains characterized by different origins, i.e., type strain ATCC 7644, clinical strain 338, and food strain 641/6II. The sensor allows for discrimination and quantification treatments at different environmental biocidal amounts and fogging times, and correlates with the microbiological inhibition, promoting the proposed sensor as a useful tool to modulate and monitor no-touch treatments.


Disinfection , Graphite , Hydrogen Peroxide , Lasers , Listeria monocytogenes , Paper , Graphite/chemistry , Hydrogen Peroxide/chemistry , Listeria monocytogenes/drug effects , Listeria monocytogenes/isolation & purification , Disinfection/methods , Cerium/chemistry , Limit of Detection , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Catalysis
3.
Antimicrob Resist Infect Control ; 13(1): 57, 2024 Jun 05.
Article En | MEDLINE | ID: mdl-38840171

AIM: Although uncommon, infections associated with peripheral intravenous catheters (PIVCs) may be responsible for severe life-threatening complications and increase healthcare costs. Few data are available on the relationship between PIVC insertion site and risk of infectious complications. METHODS: We performed a post hoc analysis of the CLEAN 3 database, a randomized 2 × 2 factorial study comparing two skin disinfection procedures (2% chlorhexidine-alcohol or 5% povidone iodine-alcohol) and two types of medical devices (innovative or standard) in 989 adults patients requiring PIVC insertion before admission to a medical ward. Insertion sites were grouped into five areas: hand, wrist, forearm, cubital fossa and upper arm. We evaluated the risk of risk of PIVC colonization (i.e., tip culture eluate in broth showing at least one microorganism in a concentration of at least 1000 Colony Forming Units per mL) and/or local infection (i.e., organisms growing from purulent discharge at PIVC insertion site with no evidence of associated bloodstream infection), and the risk of positive PIVC tip culture (i.e., PIVC-tip culture eluate in broth showing at least one microorganism regardless of its amount) using multivariate Cox models. RESULTS: Eight hundred twenty three PIVCs with known insertion site and sent to the laboratory for quantitative culture were included. After adjustment for confounding factors, PIVC insertion at the cubital fossa or wrist was associated with increased risk of PIVC colonization and/or local infection (HR [95% CI], 1.64 [0.92-2.93] and 2.11 [1.08-4.13]) and of positive PIVC tip culture (HR [95% CI], 1.49 [1.02-2.18] and 1.59 [0.98-2.59]). CONCLUSION: PIVC insertion at the wrist or cubital fossa should be avoided whenever possible to reduce the risk of catheter colonization and/or local infection and of positive PIVC tip culture.


Catheter-Related Infections , Catheterization, Peripheral , Humans , Female , Male , Catheterization, Peripheral/adverse effects , Catheter-Related Infections/prevention & control , Catheter-Related Infections/microbiology , Middle Aged , Aged , Chlorhexidine , Adult , Disinfection/methods , Povidone-Iodine , Risk Factors , Anti-Infective Agents, Local , Equipment Contamination , Wrist/microbiology
4.
BMC Oral Health ; 24(1): 648, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38824549

BACKGROUND: Ensuring the safety of dental unit waterlines (DUWLs) has become a pivotal issue in dental care practices, focusing on the health implications for both patients and healthcare providers. The inherent structure and usage conditions of DUWLs contribute to the risk of biofilm formation and bacterial growth, highlighting the need for effective disinfection solutions.The quest for a disinfection method that is both safe for clinical use and effective against pathogens such as Staphylococcus aureus and Escherichia coli in DUWLs underscores the urgency of this research. MATERIALS: Chlorine dioxide disinfectants at concentrations of 5, 20, and 80 mg/L were used to treat biofilms of S. aureus and E. coli cultured in DUWLs. The disinfection effectiveness was assessed through bacterial counts and culturing. Simultaneously, human skin fibroblast cells were treated with the disinfectant to observe changes in cell morphology and cytotoxicity. Additionally, the study included corrosion tests on various metals (carbon steel, brass, stainless steel, aluminum, etc.). RESULTS: Experimental results showed that chlorine dioxide disinfectants at concentrations of 20 mg/L and 80 mg/L significantly reduced the bacterial count of S. aureus and E. coli, indicating effective disinfection. In terms of cytotoxicity, higher concentrations were more harmful to cellular safety, but even at 80 mg/L, the cytotoxicity of chlorine dioxide remained within controllable limits. Corrosion tests revealed that chlorine dioxide disinfectants had a certain corrosive effect on carbon steel and brass, and the degree of corrosion increased with the concentration of the disinfectant. CONCLUSION: After thorough research, we recommend using chlorine dioxide disinfectant at a concentration of 20 mg/L for significantly reducing bacterial biofilms in dental unit waterlines (DUWLs). This concentration also ensures satisfactory cell safety and metal corrosion resistance.


Biofilms , Chlorine Compounds , Dental Equipment , Disinfection , Escherichia coli , Oxides , Staphylococcus aureus , Chlorine Compounds/pharmacology , Oxides/pharmacology , Biofilms/drug effects , Escherichia coli/drug effects , Humans , Staphylococcus aureus/drug effects , Disinfection/methods , Dental Equipment/microbiology , Disinfectants/pharmacology , Dental Disinfectants/pharmacology , Fibroblasts/drug effects , Bacterial Load/drug effects , In Vitro Techniques
5.
Gastroenterol Nurs ; 47(3): 171-176, 2024.
Article En | MEDLINE | ID: mdl-38847426

Although nurses and other healthcare professionals play a key role in preventing hospital-associated infections, studies show that infection control compliance rates have remained low. The purpose of this quality improvement project was to increase infection control compliance of hand hygiene and procedure room disinfection among endoscopy staff at a large urban medical center in Cincinnati, Ohio. This quality improvement project provided an education session on current evidence-based infection control guidelines to 20 participants, including registered nurses and technicians within the endoscopy department. Direct observational audits were conducted 4 weeks before and 4 weeks after the education session, measuring compliance with hand sanitizer, soap and water, and procedure room disinfection, over a period of 150 days. The project goals were met, as hand sanitizer compliance improved by 12%-83%; overall soap and water compliance improved by 20%-75%; and endoscopy procedure room disinfection compliance improved by 14%-92%.


Cross Infection , Guideline Adherence , Hospitals, Urban , Infection Control , Quality Improvement , Humans , Guideline Adherence/statistics & numerical data , Infection Control/standards , Cross Infection/prevention & control , Ohio , Disinfection/methods , Disinfection/standards , Endoscopy
6.
J Med Virol ; 96(5): e29655, 2024 May.
Article En | MEDLINE | ID: mdl-38727091

Viruses can spread through contaminated aerosols and contaminated surface materials, and effective disinfection techniques are essential for virus inactivation. Nonthermal plasma-generated reactive oxygen and nitrogen species can effectively inactivate the coronavirus. We aim to interpret the coronavirus inactivation level and mechanism of surface interaction with materials with and without dielectric barrier discharge (DBD) plasma treatment. Nonthermal plasma, particularly surface-type DBD plasma, can inactivate human coronavirus 229E (HCoV-229E) on porous (paper, wood, mask) and nonporous (plastic, stainless steel, glass, Cu) materials. Virus inactivation was analyzed using a 50% tissue culture infectivity dose (TCID50) using cell line, flow cytometry, and immunofluorescence. Surfaces contaminated with HCoV-229E were treated at different time intervals (0-5 h) with and without plasma exposure (natural decay in ambient air conditions). HCoV-229E persistence conformed to the following order: plastic > cover glass > stainless steel > mask > wood > paper > Cu with and without plasma exposure. HCoV-229E was more stable in plastic, cover glass, and stainless steel in 5 h, and the viable virus titer gradually decreased from its initial log10 order of 6.892 to 1.72, 1.53, and 1.32 TCID50/mL, respectively, under plasma exposure. No virus was observed in Cu after treatment for 5 h. The use of airflow, ambient nitrogen, and argon did not promote virus inactivation. Flow cytometry and immunofluorescence analysis demonstrated a low expression level of spike protein (fluorescence intensity) during plasma treatment and in E and M genes expression compared with the virus control.


Coronavirus 229E, Human , Plasma Gases , Virus Inactivation , Humans , Coronavirus 229E, Human/drug effects , Coronavirus 229E, Human/physiology , Virus Inactivation/drug effects , Plasma Gases/pharmacology , Cell Line , Porosity , Disinfection/methods , Stainless Steel
7.
Environ Health Perspect ; 132(5): 55001, 2024 May.
Article En | MEDLINE | ID: mdl-38728219

BACKGROUND: In response to the COVID-19 pandemic, new evidence-based strategies have emerged for reducing transmission of respiratory infections through management of indoor air. OBJECTIVES: This paper reviews critical advances that could reduce the burden of disease from inhaled pathogens and describes challenges in their implementation. DISCUSSION: Proven strategies include assuring sufficient ventilation, air cleaning by filtration, and air disinfection by germicidal ultraviolet (UV) light. Layered intervention strategies are needed to maximize risk reduction. Case studies demonstrate how to implement these tools while also revealing barriers to implementation. Future needs include standards designed with infection resilience and equity in mind, buildings optimized for infection resilience among other drivers, new approaches and technologies to improve ventilation, scientific consensus on the amount of ventilation needed to achieve a desired level of risk, methods for evaluating new air-cleaning technologies, studies of their long-term health effects, workforce training on ventilation systems, easier access to federal funds, demonstration projects in schools, and communication with the public about the importance of indoor air quality and actions people can take to improve it. https://doi.org/10.1289/EHP13878.


Air Pollution, Indoor , COVID-19 , SARS-CoV-2 , Ventilation , COVID-19/transmission , COVID-19/prevention & control , Humans , Air Pollution, Indoor/prevention & control , Ventilation/methods , Air Microbiology , Disinfection/methods , Respiratory Tract Infections/prevention & control , Respiratory Tract Infections/transmission
8.
Sci Adv ; 10(18): eadl5067, 2024 May 03.
Article En | MEDLINE | ID: mdl-38701201

Airborne pathogens retain prolonged infectious activity once attached to the indoor environment, posing a pervasive threat to public health. Conventional air filters suffer from ineffective inactivation of the physics-separated microorganisms, and the chemical-based antimicrobial materials face challenges of poor stability/efficiency and inefficient viral inactivation. We, therefore, developed a rapid, reliable antimicrobial method against the attached indoor bacteria/viruses using a large-scale tunneling charge-motivated disinfection device fabricated by directly dispersing monolayer graphene on insulators. Free charges can be stably immobilized under the monolayer graphene through the tunneling effect. The stored charges can motivate continuous electron loss of attached microorganisms for accelerated disinfection, overcoming the diffusion limitation of chemical disinfectants. Complete (>99.99%) and broad-spectrum disinfection was achieved <1 min of attachment to the scaled-up device (25 square centimeters), reliably for 72 hours at high temperature (60°C) and humidity (90%). This method can be readily applied to high-touch surfaces in indoor environments for pathogen control.


Disinfection , Electronics , Graphite , Disinfection/methods , Electronics/methods , Graphite/chemistry , Microbial Viability , Bacteria
9.
PeerJ ; 12: e17268, 2024.
Article En | MEDLINE | ID: mdl-38708351

Objective: To study the efficacy of PADTM Plus-based photoactivated disinfection (PAD) for treating denture stomatitis (DS) in diabetic rats by establishing a diabetic rat DS model. Methods: The diabetic rat DS model was developed by randomly selecting 2-month-old male Sprague-Dawley rats and dividing them into four groups. The palate and denture surfaces of rats in the PAD groups were incubated with 1 mg/mL toluidine blue O for 1 min each, followed by a 1-min exposure to 750-mW light-emitting diode light. The PAD-1 group received one radiation treatment, and the PAD-2 group received three radiation treatments over 5 days with a 1-day interval. The nystatin (NYS) group received treatment for 5 days with a suspension of NYS of 100,000 IU. The infection group did not receive any treatment. In each group, assessments included an inflammation score of the palate, tests for fungal load, histological evaluation, and immunohistochemical detection of interleukin-17 (IL-17) and tumor necrosis factor (TNF-α) conducted 1 and 7 days following the conclusion of treatment. Results: One day after treatment, the fungal load on the palate and dentures, as well as the mean optical density values of IL-17 and TNF-α, were found to be greater in the infection group than in the other three treatment groups (P < 0.05). On the 7th day after treatment, these values were significantly higher in the infection group than in the PAD-2 and NYS groups (P < 0.05). Importantly, there were no differences between the infection and PAD-1 groups nor between the PAD-2 and NYS groups (P > 0.05). Conclusions: PAD effectively reduced the fungal load and the expressions of IL-17 and TNF-α in the palate and denture of diabetic DS rats. The efficacy of multiple-light treatments was superior to that of single-light treatments and similar to that of NYS.


Diabetes Mellitus, Experimental , Disinfection , Rats, Sprague-Dawley , Stomatitis, Denture , Animals , Male , Rats , Stomatitis, Denture/microbiology , Stomatitis, Denture/radiotherapy , Stomatitis, Denture/drug therapy , Disinfection/methods , Tolonium Chloride/pharmacology , Tolonium Chloride/therapeutic use , Tumor Necrosis Factor-alpha/metabolism , Interleukin-17/metabolism , Disease Models, Animal
10.
Arch Microbiol ; 206(6): 276, 2024 May 23.
Article En | MEDLINE | ID: mdl-38777923

Due to its increased safety over ultraviolet light, there is interest in the development of antimicrobial violet-blue light technologies for infection control applications. To ensure compatibility with exposed materials and tissue, the light irradiances and dose regimes used must be suitable for the target application. This study investigates the antimicrobial dose responses and germicidal efficiency of 405 nm violet-blue light when applied at a range of irradiance levels, for inactivation of surface-seeded and suspended bacteria. Bacteria were seeded onto agar surfaces (101-108 CFUplate-1) or suspended in PBS (103-109 CFUmL-1) and exposed to increasing doses of 405-nm light (≤ 288 Jcm-2) using various irradiances (0.5-150 mWcm-2), with susceptibility at equivalent light doses compared. Bacterial reductions ≥ 96% were demonstrated in all cases for lower irradiance (≤ 5 mWcm-2) exposures. Comparisons indicated, on a per unit dose basis, that significantly lower doses were required for significant reductions of all species when exposed at lower irradiances: 3-30 Jcm-2/0.5 mWcm-2 compared to 9-75 Jcm-2/50 mWcm-2 for low cell density (102 CFUplate-1) surface exposures and 22.5 Jcm-2/5 mWcm-2 compared to 67.5 Jcm-2/150 mWcm-2 for low density (103 CFUmL-1) liquid exposures (P ≤ 0.05). Similar patterns were observed at higher densities, excluding S. aureus exposed at 109 CFUmL-1, suggesting bacterial density at predictable levels has minimal influence on decontamination efficacy. This study provides fundamental evidence of the greater energy efficacy of 405-nm light for inactivation of clinically-significant pathogens when lower irradiances are employed, further supporting its relevance for practical decontamination applications.


Decontamination , Light , Decontamination/methods , Bacteria/radiation effects , Bacteria/drug effects , Disinfection/methods , Microbial Viability/radiation effects , Staphylococcus aureus/radiation effects , Staphylococcus aureus/drug effects
11.
Microb Cell Fact ; 23(1): 148, 2024 May 23.
Article En | MEDLINE | ID: mdl-38783243

BACKGROUND: The continuous progress in nanotechnology is rapid and extensive with overwhelming futuristic aspects. Through modernizing inventive synthesis protocols, a paradigm leapfrogging in novelties and findings are channeled toward fostering human health and sustaining the surrounding environment. Owing to the overpricing and jeopardy of physicochemical synthesizing approaches, the quest for ecologically adequate schemes is incontestable. By developing environmentally friendly strategies, mycosynthesis of nanocomposites has been alluring. RESULTS: Herein, a novel architecture of binary CuO and TiO2 in nanocomposites form was fabricated using bionanofactory Candida sp., for the first time. For accentuating the structural properties of CuTi nanocomposites (CuTiNCs), various characterization techniques were employed. UV-Vis spectroscopy detected SPR at 350 nm, and XRD ascertained the crystalline nature of a hybrid system. However, absorption peaks at 8, 4.5, and 0.5 keV confirmed the presence of Cu, Ti and oxygen, respectively, in an undefined assemblage of polygonal-spheres of 15-75 nm aggregated in the fungal matrix of biomolecules as revealed by EDX, SEM and TEM. However, FTIR, ζ-potential and TGA reflected long-term stability (- 27.7 mV) of self-functionalized CuTiNCs. Interestingly, a considerable and significant biocide performance was detected at 50 µg/mL of CuTiNCs against some human and plant pathogens, compared to monometallic counterparts. Further, CuTiNCs (200 µg/mL) ceased significantly the development of Staphylococcus aureus, Pseudomonas aeruginosa and Candida albicans biofilms by 80.3 ± 1.4, 68.7 ± 3.0 and 55.7 ± 3.0%, respectively. Whereas, 64.63 ± 3.5 and 89.82 ± 4.3% antimicrofouling potentiality was recorded for 100 and 200 µg/ml of CuTiNCs, respectively; highlighting their destructive effect against marine microfoulers cells and decaying of their extracellular polymeric skeleton as visualized by SEM. Moreover, CuTiNCs (100 and 200 µg/ml) exerted significantly outstanding disinfection potency within 2 h by reducing the microbial load (i.e., total plate count, mold & yeast, total coliforms and faecal Streptococcus) in domestic and agricultural effluents reached >50%. CONCLUSION: The synergistic efficiency provided by CuNPs and TiNPs in mycofunctionalized CuTiNCs boosted its recruitment as antiphytopathogenic, antibiofilm, antimicrofouling and disinfectant agent in various realms.


Biofilms , Copper , Nanocomposites , Titanium , Wastewater , Nanocomposites/chemistry , Biofilms/drug effects , Copper/chemistry , Copper/pharmacology , Titanium/chemistry , Titanium/pharmacology , Wastewater/microbiology , Wastewater/chemistry , Candida/drug effects , Disinfection/methods , Anti-Infective Agents/pharmacology , Anti-Infective Agents/chemistry , Biofouling/prevention & control , Candida albicans/drug effects , Microbial Sensitivity Tests
12.
J Orthop Surg Res ; 19(1): 304, 2024 May 20.
Article En | MEDLINE | ID: mdl-38769535

BACKGROUND: Periprosthetic joint infection is a serious complication following joint replacement. The development of bacterial biofilms bestows antibiotic resistance and restricts treatment via implant retention surgery. Electromagnetic induction heating is a novel technique for antibacterial treatment of metallic surfaces that has demonstrated in-vitro efficacy. Previous studies have always employed stationary, non-portable devices. This study aims to assess the in-vitro efficacy of induction-heating disinfection of metallic surfaces using a new Portable Disinfection System based on Induction Heating. METHODS: Mature biofilms of three bacterial species: S. epidermidis ATCC 35,984, S. aureus ATCC 25,923, E. coli ATCC 25,922, were grown on 18 × 2 mm cylindrical coupons of Titanium-Aluminium-Vanadium (Ti6Al4V) or Cobalt-chromium-molybdenum (CoCrMo) alloys. Study intervention was induction-heating of the coupon surface up to 70ºC for 210s, performed using the Portable Disinfection System (PDSIH). Temperature was monitored using thermographic imaging. For each bacterial strain and each metallic alloy, experiments and controls were conducted in triplicate. Bacterial load was quantified through scraping and drop plate techniques. Data were evaluated using non-parametric Mann-Whitney U test for 2 group comparison. Statistical significance was fixed at p ≤ 0.05. RESULTS: All bacterial strains showed a statistically significant reduction of CFU per surface area in both materials. Bacterial load reduction amounted to 0.507 and 0.602 Log10 CFU/mL for S. aureus on Ti6Al4V and CoCrMo respectively, 5.937 and 3.500 Log10 CFU/mL for E. coli, and 1.222 and 0.372 Log10 CFU/mL for S. epidermidis. CONCLUSIONS: Electromagnetic induction heating using PDSIH is efficacious to reduce mature biofilms of S aureus, E coli and S epidermidis growing on metallic surfaces of Ti6Al4V and CoCrMo alloys.


Alloys , Biofilms , Disinfection , Escherichia coli , Prosthesis-Related Infections , Staphylococcus aureus , Titanium , Biofilms/drug effects , Disinfection/methods , Escherichia coli/growth & development , Staphylococcus aureus/drug effects , Prosthesis-Related Infections/prevention & control , Prosthesis-Related Infections/microbiology , Staphylococcus epidermidis/drug effects , Joint Prosthesis/microbiology , Arthroplasty, Replacement/instrumentation , Arthroplasty, Replacement/methods , Heating/instrumentation , Heating/methods , Humans , Electromagnetic Phenomena , Vitallium
13.
Sci Total Environ ; 934: 173210, 2024 Jul 15.
Article En | MEDLINE | ID: mdl-38750753

Controlling the dissemination of antibiotic-resistant bacteria (ARB) and antibiotic resistance genes (ARGs) is a global concern. While commonly used chlorine disinfectants can damage or even kill ARB, dissolved oxygen (DO) may affect the formation of reactive chlorine species. This leads to the hypothesis that DO may play roles in mediating the effectiveness of chlorine disinfection for antibiotic resistance. To this end, this study investigated the impacts of DO on the efficiency of chlorine disinfection for antibiotic resistance. The results revealed that DO could increase the inactivation efficiency of ARB under chloramine and free chlorine exposure at practically relevant concentrations. Reactive species induced by DO, including H2O2, O2-, and OH, inactivated ARB strains by triggering oxidative stress response and cell membrane damage. In addition, the removal efficiency of extracellular ARGs (i.e. tetA and blaTEM) was enhanced with increasing dosage of free chlorine or chloramine under aerobic conditions. DO facilitated the fragmentation of plasmids, contributing to the degradation of extracellular ARGs under exposure to chlorine disinfectants. The findings suggested that DO facilitates disinfection efficiency for antibiotic resistance in water treatment systems.


Chlorine , Disinfectants , Disinfection , Oxygen , Chlorine/pharmacology , Disinfection/methods , Disinfectants/pharmacology , Water Purification/methods , Drug Resistance, Microbial/genetics , Drug Resistance, Bacterial/genetics , Anti-Bacterial Agents/pharmacology
14.
Sci Total Environ ; 934: 173075, 2024 Jul 15.
Article En | MEDLINE | ID: mdl-38750759

Unregulated antibiotic use has led to the proliferation of antibiotic-resistant bacteria (ARB) in aquatic environments. Ultraviolet light-emitting diodes (UV LEDs) have evolved as an innovative technology for inactivating microorganisms offering several advantages over traditional mercury lamps. This research concentrated on utilizing UV LEDs with three distinct wavelengths (265 nm, 275 nm, and 285 nm) to inactivate E. coli DH10ß encoding the ampicillin-resistant blaTEM-1 gene in its plasmid. Non-linear models, such as Geeraerd's and Weibull, provided more accurate characterization of the inactivation profiles than the traditional log-linear model due to the incorporation of both biological mechanisms and a deterministic approach within non-linear models. The inactivation rates of ARB were higher than antibiotic-sensitive bacteria (ASB) when subjected to UV LEDs. The highest inactivation rates were observed when all microorganisms were exposed to 265 nm. Photoreactivation emerged as the primary mechanism responsible for repairing DNA damage induced by UV LEDs. 285 nm showed the highest reactivation efficiencies for ARB under different fluences. At higher fluences, both 265 and 275 nm displayed similar effectiveness in suppressing reactivation, while at lower fluences, 275 nm exhibited better efficacies in controlling the reactivation. Therefore, the inhibition of reactivation was influenced by the extent of damage incurred to both DNA and enzymes. In nutrient-poor media (0.9 % NaCl), ASB did not exhibit any reactivation potential. However, the addition of Luria-Bertani (LB) broth promoted the reactivation of ASB. Lower fluence rate was more beneficial at 265 nm whereas higher fluence rates were more effective for longer wavelengths. The inactivation of ARB was enhanced by dissolved organic carbon (DOC) at low fluences. However, the removal of ARB was reduced due to the presence of DOC at higher fluences. The highest energy demand for ARB inactivation was reported at 285 nm. ENVIRONMENTAL IMPLICATION: The excessive and unregulated utilization of antibiotics has emerged as a significant issue for public health. This paper presents a comprehensive analysis of the effectiveness of UV LEDs, an emerging technology, in the inactivation of antibiotic-resistant bacteria (ARB). This research paper explores the kinetics of UV LEDs with different wavelengths to inactivate ARB along with the reactivation efficiencies. This research work also explores the impact and relevant mechanisms of the impact of dissolved organic carbon (DOC) on the inactivation of ARB by UV LEDs.


Ultraviolet Rays , Anti-Bacterial Agents/pharmacology , Drug Resistance, Bacterial , Kinetics , Escherichia coli/drug effects , Disinfection/methods , Bacteria
15.
Water Res ; 257: 121685, 2024 Jun 15.
Article En | MEDLINE | ID: mdl-38728774

Water disinfection is undoubtedly regarded as a critical step in ensuring the water safety for human consumption, and ozone is widely used as a highly effective disinfectant for the control of pathogenic microorganisms in water. Although the diminished ozone efficiencies in complex water matrices have been widely reported, the specific extent to which individual components of matrix act on the virus inactivation by ozone remains unclear, and effective methodologies to predict the comprehensive effects of various factors are needed. In this study, the decoupled impact of the intricate water matrix on the ozone inactivation of viruses was systematically investigated and assessed from a simulative perspective. The concept of "equivalent ozone depletion rate constant" (k') was introduced to quantify the influence of different species, and a kinetic model was developed based on the k' values for simulating the ozone inactivation processes in complex matrix. The mechanisms through which diverse species influenced the ozone inactivation effectiveness were identified: 1) competition effects (k' = 105∼107 M-1s-1), including organic matters and reductive ions (SO32-, NO2-, and I-), which were the most influential species inhibiting the virus inactivation; 2) shielding effects (k' = 103∼104 M-1s-1), including Ca2+, Mg2+, and kaolin; 3) insignificant effects (k' = 0∼1 M-1s-1), including Cl-, SO42-, NO3-, NH4+, and Br-; 4) promotion effects (k' = ∼-103 M-1s-1), including CO32- and HCO3-. Prediction of ozone disinfection efficiency and evaluation of species contribution under complex aquatic matrices were successfully realized utilizing the model. The systematic understanding and methodologies developed in this research provide a reliable framework for predicting ozone inactivation efficiency under complex matrix, and a potential tool for accurate disinfectant dosage determination and interfering factors control in actual wastewater treatment processes.


Disinfection , Ozone , Virus Inactivation , Wastewater , Ozone/pharmacology , Wastewater/virology , Virus Inactivation/drug effects , Disinfection/methods , Water Purification , Disinfectants/pharmacology , Models, Theoretical , Kinetics
16.
Water Res ; 257: 121702, 2024 Jun 15.
Article En | MEDLINE | ID: mdl-38749337

While online monitoring of physicochemical parameters has widely been incorporated into drinking water treatment systems, online microbial monitoring has lagged behind, resulting in the use of surrogate parameters (disinfectant residual, applied dose, concentration × time, CT) to assess disinfection system performance. Online flow cytometry (online FCM) allows for automated quantification of total and intact microbial cells. This study sought to investigate the feasibility of online FCM for full-scale drinking water ozone disinfection system performance monitoring. A water treatment plant with high lime solids turbidity in the ozone contactor influent was selected to evaluate the online FCM in challenging conditions. Total and intact cell counts were monitored for 40 days and compared to surrogate parameters (ozone residual, ozone dose, and CT) and grab sample assay results for cellular adenosine triphosphate (cATP), heterotrophic plate counts (HPC), impedance flow cytometry, and 16S rRNA gene sequencing. Online FCM provided insight into the dynamics of the full-scale ozone system, including offering early warning of increased contactor effluent cell concentrations, which was not observed using surrogate measures. Positive correlations were observed between online FCM intact cell counts and cATP levels (Kendall's tau=0.40), HPC (Kendall's tau=0.20), and impedance flow cytometry results (Kendall's tau=0.30). Though a strong correlation between log intact cell removal and CT was not observed, 16S rRNA gene sequencing results showed that passage through the ozone contactor significantly changed the microbial community (p < 0.05). Potential causes of the low overall cell inactivation in the contactor and the significant changes in the microbial community after ozonation include regrowth in the later chambers of the contactor and varied ozone resistance of drinking water microorganisms. This study demonstrates the suitability of direct, online microbial analysis for monitoring full-scale disinfection systems.


Disinfection , Drinking Water , Flow Cytometry , Ozone , Water Purification , Flow Cytometry/methods , Disinfection/methods , Drinking Water/microbiology , Water Purification/methods
17.
Anal Methods ; 16(20): 3209-3219, 2024 May 23.
Article En | MEDLINE | ID: mdl-38713168

BACKGROUND: halogenic disinfectants have been shown to produce toxic and carcinogenic disinfection by-products in the water disinfection process. Dibromohydantoin (DBDMH) is a commonly used water disinfectant in aquaculture. Aquaculture water has more complex matrix, and the analytical method for disinfection by-products (DBPs) have not been reported. Since the content of DBPs is related to the external conditions such as ultraviolet irradiation, temperatures, pH and humic acid. The semi-target screening method for mainly DBPs based on tracing mass spectrometry fragments of bromide and accurate mass of high resolution mass spectrometry was established by ultra performance liquid chromatography-quadrupole-time of flight-mass spectrometry (UPLC-Q-tof/MS). Br-DBPs as a important class of DBPs from DBDMH, which quantification analysis methods were developed based on accurate mass of high resolution mass spectrometry. METHODS: through screening method to identify unknown Br-DBPs and quantitative analysis of the typical 4-bromophenol by-product of accurate mass was established. The conditions of the instrument parameters of mass spectrometry and SPE sample preparation procedure in complex real sample were optimized. The high efficiency method was demonstrated for the determination of Br-DBPs with a good linear correlation (R2 = 0.999) in the range of 0.500-200 µg L-1 and limit of detections (LODs) and limit of quantifications (LOQs) were 0.0250 ng L-1 and 0.0834 ng L-1, respectively. CONCLUSION: the developed screening and quantification analytical strategy for Br-DBPs is rapid, accurate and sensitivity applicable for environmental in aquaculture water monitoring.


Aquaculture , Disinfectants , Mass Spectrometry , Water Pollutants, Chemical , Aquaculture/methods , Chromatography, High Pressure Liquid/methods , Water Pollutants, Chemical/analysis , Mass Spectrometry/methods , Disinfectants/analysis , Disinfectants/chemistry , Disinfection/methods
18.
J Environ Sci (China) ; 144: 199-211, 2024 Oct.
Article En | MEDLINE | ID: mdl-38802231

As a strong oxidizing agent, ozone is used in some water treatment facilities for disinfection, taste and odor control, and removal of organic micropollutants. Phenylalanine (Phe) was used as the target amino acid to comprehensively investigate variability of disinfection byproducts (DBPs) formation during chlorine disinfection and residual chlorine conditions subsequent to ozonation. The results showed that subsequent to ozonation, the typical regulated and unregulated DBPs formation potential (DBPsFP), including trichloromethane (TCM), dichloroacetonitrile (DCAN), chloral hydrate (CH), dichloroacetic acid (DCAA), trichloroacetic acid (TCAA), and trichloroacetamide (TCAcAm) increased substantially, by 2.4, 3.3, 5.6, 1.2, 2.5, and 6.0 times, respectively, compared with only chlorination. Ozonation also significantly increased the DBPs yield under a 2 day simulated residual chlorine condition that mimicked the water distribution system. DBPs formations followed pseudo first order kinetics. The formation rates of DBPs in the first 6 hr were higher for TCM (0.214 hr-1), DCAN (0.244 hr-1), CH (0.105 hr-1), TCAcAm (0.234 hr-1), DCAA (0.375 hr-1) and TCAA (0.190 hr-1) than thereafter. The peak DBPsFP of TCM, DCAN, CH, TCAcAm, DCAA, and TCAA were obtained when that ozonation time was set at 5-15 min. Ozonation times > 30 min increased the mineralization of Phe and decreased the formation of DBPs upon chlorination. Increasing bromine ion (Br-) concentration increased production of bromine- DBPs and decreased chlorine-DBPs formation by 59.3%-92.2% . Higher ozone dosages and slight alkaline favored to reduce DBP formation and cytotoxicity. The ozonation conditions should be optimized for all application purposes including DBPs reduction.


Disinfection , Halogenation , Ozone , Phenylalanine , Water Pollutants, Chemical , Water Purification , Ozone/chemistry , Disinfection/methods , Water Purification/methods , Water Pollutants, Chemical/chemistry , Water Pollutants, Chemical/analysis , Phenylalanine/chemistry , Disinfectants/chemistry , Disinfectants/analysis , Chlorine/chemistry
19.
Photobiomodul Photomed Laser Surg ; 42(5): 366-374, 2024 May.
Article En | MEDLINE | ID: mdl-38776543

Objective: The proposed study aims to compare the effectiveness of conventional endodontic treatment (ET) with that of ET associated with antimicrobial photodynamic therapy (aPDT) in patients with apical lesion. Methods: Controlled, double-blind, randomized clinical trial (RCT); superiority study with three parallel arms. Randomization will be conducted in exchange blocks of six, with allocation 1:1:1. The control group will receive conventional ET, while experimental group 1 (EG1) will receive conventional ET + aPDT with laser at 660 nm, fluence of 600 J/cm2; EG2 will receive conventional ET + aPDT with laser at 660 nm, fluence of 1200 J/cm2. The primary outcome will be canal disinfection before treatment, measured by analysis of colony formation (CFU/mL) and the success rate measured after 6 months on the clinical and radiographic evaluations. The mean and standard deviation will be calculated for continuous outcomes, and the CFU/mL mean between groups will be evaluated by ANOVA test. The Chi-squared test will be calculated for binary outcomes. A logistic regression analysis will be performed to assess differences in the success rate between groups, adjusted for the covariates. The Stata 18 software will be used, with a significance threshold of 5%. Conclusions: Few RCTs have evaluated the effectiveness of aPDT in root canal disinfection in patients with permanent dentition presenting apical lesion. New RCTs with larger numbers of participants are needed to support using aPDT as an adjuvant to conventional ET in root canal disinfection for routine use in clinical practice. The trial was registered prospectively in ClinicalTrials.gov (NCT05916859).


Disinfection , Molar , Photochemotherapy , Humans , Photochemotherapy/methods , Double-Blind Method , Disinfection/methods , Root Canal Therapy/methods , Female , Male , Photosensitizing Agents/therapeutic use , Adult , Dental Pulp Cavity , Adolescent
...