Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 5.474
Filter
1.
Front Public Health ; 12: 1444411, 2024.
Article in English | MEDLINE | ID: mdl-39228845

ABSTRACT

Introduction: Exposure to harmful aerosols is of increasing public health concern due to the SARS-CoV-2 pandemic and wildland fires. These events have prompted risk reduction behaviors, notably the use of disposable respiratory protection. This project investigated whether craniofacial morphology impacts the efficiency of disposable masks (N95, KN95, surgical masks, KF94) most often worn by the public to protect against toxic and infectious aerosols. This project was registered with ClinicaltTrials.gov (NCT05388201; registration May 18, 2022). Methods: One-hundred participants (50 men, 50 women) visited the Environmental Protection Agency's Human Studies Facility in Chapel Hill, NC between 2022-2023. Craniometrics and 3D scans were used to separate participants into four clusters. Boosting and elastic net regression yielded five measurements (bizygomatic breadth, nose length, bizygomatic nasal arc, neck circumference, ear breadth) that were the best predictors of filtration efficiency based on overall model fit. Fitted filtration efficiency was quantified for each mask at baseline and when tightened using an ear-loop clip. Results: The mean unmodified mask performance ranged from 55.3% (15.7%) in the large KF94 to 69.5% (12.3%) in the KN95. Modified performance ranged from 66.3% (9.4%) in the surgical to 80.7% (12.0%) in the KN95. Clusters with larger face width and neck circumference had higher unmodified mask efficiency. Larger nose gap area and nose length decreased modified mask performance. Discussion: We identify face width, nose size, nose shape, neck circumference, and ear breadth as specific features that modulate disposable mask fit in both unmodified and modified conditions. This information can optimize guidance on respiratory protection afforded by disposable ear-loop masks.


Subject(s)
Disposable Equipment , Filtration , Masks , Adult , Female , Humans , Male , Middle Aged , Young Adult , Aerosols , Cephalometry , Equipment Design , Filtration/instrumentation , Respiratory Protective Devices
2.
N Z Med J ; 137(1600): 62-65, 2024 Aug 02.
Article in English | MEDLINE | ID: mdl-39088810

ABSTRACT

AIM: The aim of this study was to follow the instruments' pathways and cost each segment to calculate whether reusable or disposable ophthalmic instruments offer better value for money for intravitreal injections. METHODS: The cycles and costs of reusable and single-use disposable instruments used for intravitreal injections were mapped out, including purchase costs, transport to and from the place of use, opening and disposal, sterilisation, replacement, salary costs of staff involved, etc. results: The cost of using reusable instruments for intravitreal injections (NZ$29.00) was lower than the cost of using disposable instruments ($30.51) by $1.51 per patient. CONCLUSIONS: Intravitreal injections performed with reusable instruments offer better value for money than when performed with disposable instruments. This equates to a beneficial financial saving just for this one low-complexity case. Such savings can multiply significantly when considering the instruments used in a wider variety of ophthalmic procedures. There are of course trade-offs between safety, quality, cost and sustainability.


Subject(s)
Disposable Equipment , Equipment Reuse , Intravitreal Injections , Intravitreal Injections/instrumentation , Intravitreal Injections/economics , Disposable Equipment/economics , Humans , Equipment Reuse/economics , New Zealand , Cost-Benefit Analysis
3.
PDA J Pharm Sci Technol ; 78(4): 528-529, 2024 Aug 23.
Article in English | MEDLINE | ID: mdl-39179389

ABSTRACT

As autoinjector requirements become increasingly diverse and pharma companies look for quicker routes to market, with lower costs and improved sustainability, there is an increasing trend towards devices with a reusable element. The flexibility in reusable elements can be beneficial for pharma companies with access to these platforms, allowing a relatively rapid transition between different drug combinations. However, it can also lead to devices designed to cover a wide range of requirements which are over designed for their actual more limited end use. The challenge of creating both a cost and sustainability optimised platform device is significantly harder than if developing a single use device with a specific purpose in mind. This paper looks at the range of reusable products on the market, examining some of the assertions around the cost and sustainability benefits of these devices as well as where there are trade-offs relative to current single use format devices.


Subject(s)
Equipment Reuse , Equipment Reuse/standards , Humans , Cost-Benefit Analysis , Drug Industry/methods , Drug Industry/standards , Technology, Pharmaceutical/methods , Injections , Equipment Design , Disposable Equipment/standards
4.
BMC Ophthalmol ; 24(1): 376, 2024 Aug 26.
Article in English | MEDLINE | ID: mdl-39187788

ABSTRACT

BACKGROUND: Warm compresses are the routine treatment for Meibomian gland dysfunction (MGD) in daily life, but in order to achieve satisfactory efficacy, the treatment needs to be sustained over a long time, which can have an impact on the patient compliance. A more convenient warm compresses will help improve the patient compliance. Therefore, the purpose of the study is to investigate the efficacy and safety of the disposable eyelid warming masks for treatment of dry eye disease (DED) due to MGD. METHODS: This was a randomized, controlled, non-masked, two-center clinical trial. One hundred and forty-four patients were treated by the masks or the hot towel twice daily for 12 weeks. Patients were evaluated at baseline, 4-week and 12-week visits for subjective symptoms, objective signs and safety assessments, including ocular symptom scores, ocular surface disease index (OSDI), tear break-up time (BUT), corneal fluorescein staining (CFS), Schirmer I test (SIT), meibum quality, meibum expressibility, and adverse events (AEs). RESULTS: A totle of 134 patients were followed in the study. The mean age of the masks group (14 males and 52 females) and the hot towel group (20 males and 48 females) was 43.7 ± 13.5 years and 39.5 ± 13.9 years, respectively. At 4-week visit, there were significant statistical differences in ocular symptom scores, OSDI and CFS between two groups (P < 0.05). Except for SIT, the treatment group showed a greater improvement in subjective symptoms and objective signs than the control group at 12-week visit. (P < 0.05). In addition, 40 AEs occurred in 27 patients (37.5%) in the treatment group, and 34 AEs occurred in 21 patients (29.17%) in the control group. No serious AEs were reported. CONCLUSIONS: The masks had a good efficacy and safety in the treatment of DED due to MGD, and might offer an attractive treatment option for some patients. TRIAL REGISTRATION: The study was registered at Chinese Clinical Trial Registry (ChiCTR1900025443) on August 26, 2019.


Subject(s)
Dry Eye Syndromes , Meibomian Gland Dysfunction , Humans , Female , Male , Dry Eye Syndromes/therapy , Dry Eye Syndromes/physiopathology , Middle Aged , Meibomian Gland Dysfunction/therapy , Adult , Masks/adverse effects , Meibomian Glands , Treatment Outcome , Disposable Equipment , Aged , Tears/physiology , Tears/metabolism , Hyperthermia, Induced/instrumentation , Hyperthermia, Induced/methods , Hyperthermia, Induced/adverse effects
5.
BMC Urol ; 24(1): 149, 2024 Jul 18.
Article in English | MEDLINE | ID: mdl-39026274

ABSTRACT

OBJECTIVES: To compare the clinical efficacy and safety of single-use and reusable digital flexible ureteroscopy for the treatment of lower pole stones. METHODS: We enrolled 135 patients underwent reusable flexible ureteroscopy (FURS) and 78 patients underwent single-use digital FURS. Demographic, clinical variables, anatomical parameters of the lower calyx and perioperative indicators were compared in the two groups. RESULTS: Thirty-six patients in the infundibuloureter angle (IPA) < 45° subgroup had a mini-percutaneous nephrolithotomy (mini-PCNL), including 25 patients in the reusable FURS group and 11 patients in the single-use FURS group. The demographic and clinical variables in the two FURS groups were comparable. There was no statistical difference in the success rate of stone searching (P > 0.05). In terms of the success rate of lithotripsy, there was also no statistical difference in the IPA ≥ 45° subgroup (P > 0.05), whereas single-use FURS was superior in the IPA < 45° subgroup (χ2 = 6.513, P = 0.011). The length of the working fiber in the reusable FURS and single-use FURS groups was 3.20 ± 0.68 mm and 1.75 ± 0.47 mm, respectively (t = 18.297, P < 0.05). The use of a stone basket in the reusable FURS (31/135, 23.0%) was significantly higher than that in the single-use FURS (8/78, 10.3%) (χ2 = 5.336, P = 0.021). Compared with the reusable FURS group, the single-use FURS group had shorter operation times (P < 0.05) and higher stone-free rate (SFR) (χ2 = 4.230, P = 0.040). There was no statistical difference in the intraoperative transfer of mini-PCNL and postoperative complications between the two groups (P > 0.05). CONCLUSIONS: Single-use and reusable FURS are alternative methods for removal of lower pole stones (i.e., 2 cm or less). Single-use FURS has a high success rate of lithotripsy, shorter operation time, and high stone-free rate.


Subject(s)
Equipment Reuse , Kidney Calculi , Ureteroscopes , Ureteroscopy , Humans , Ureteroscopy/methods , Ureteroscopy/instrumentation , Male , Female , Retrospective Studies , Kidney Calculi/surgery , Middle Aged , Adult , Case-Control Studies , Treatment Outcome , Equipment Design , Disposable Equipment , Aged
7.
BMC Surg ; 24(1): 212, 2024 Jul 19.
Article in English | MEDLINE | ID: mdl-39030560

ABSTRACT

BACKGROUND: The ultrasonic scalpel is widely used during surgery. It is safe and effective to close the pulmonary artery branch vessels of 7 mm or below with an ultrasonic energy device as reported. However, there have been no multicenter randomized clinical trial to assess the safety and effectiveness of using ultrasonic scalpel to coagulate 5-7 mm blood vessels in thoracic surgery. METHODS: This is a prospective, multicenter, randomized, parallel controlled, non-inferiority clinical trial. A total of 144 eligible patients planning to undergo lung or esophageal surgery will be randomly allocated to the experimental group and the control group. The investigational product (Disposable Ultrasonic Shears manufactured by Reach Surgical, Inc.) and the control product (Harmonic Ace + 7, 5 mm Diameter Shears with Advanced Hemostasis) will be used in each group. The primary endpoint is the success rate of coagulating target blood vessels during surgery. Secondary endpoints include postoperative rebleeding, intraoperative bleeding volume, drainage volume, surgical duration, etc. Postoperative follow-up before and after discharge will be performed. DISCUSSION: This clinical trial aims to evaluate the safety and effectiveness of using the investigational product (Disposable Ultrasonic Shears manufactured by Reach Surgical, Inc.) and that of the control product (Harmonic Ace + 7, 5 mm Diameter Shears with Advanced Hemostasis) to coagulate 5-7 mm blood vessels in thoracic surgery. TRIAL REGISTRATION: ClinicalTrials.gov: NCT06002737. The trial was prospectively registered on 16 August 2023, https://www. CLINICALTRIALS: gov/study/NCT06002737 .


Subject(s)
Disposable Equipment , Humans , Prospective Studies , Ultrasonic Surgical Procedures/instrumentation , Ultrasonic Surgical Procedures/methods , Hemostasis, Surgical/instrumentation , Hemostasis, Surgical/methods , Male , Female , Blood Loss, Surgical/prevention & control , Adult , Esophagus/surgery , Multicenter Studies as Topic , Treatment Outcome , Equivalence Trials as Topic , Middle Aged , Thoracic Surgical Procedures/methods , Thoracic Surgical Procedures/instrumentation
8.
J Hazard Mater ; 477: 135308, 2024 Sep 15.
Article in English | MEDLINE | ID: mdl-39053070

ABSTRACT

In the natural environment, a symphony of environmental factors including sunlight exposure, current fluctuations, sodium chloride concentrations, and sediment dynamics intertwine, potentially magnifying the impacts on the aging process of disposable face masks (DFMs), thus escalating environmental risks. Employing Regular Two-Level Factorial Design, the study scrutinized interactive impacts of ultraviolet radiation, sand abrasion, acetic acid exposure, sodium chloride levels, and mechanical agitation on mask aging. Aging mechanisms and environmental risks linked with DFMs were elucidated through two-dimensional correlation analyses and risk index method. Following a simulated aging duration of three months, a single mask exhibited the propensity to release a substantial quantity of microplastics, ranging from 38,800 ± 360 to 938,400 ± 529 particles, and heavy metals, with concentrations from 0.06 ± 0.02 µg/g (Pb) to 29.01 ± 1.83 µg/g (Zn). Besides, specific contaminants such as zinc ions (24.24 µg/g), chromium (VI) (4.20 µg/g), thallium (I) (0.92 µg/g), tetracycline (0.51 µg/g), and acenaphthene (1.73 µg/g) can be adsorbed significantly by aged masks. The study elucidates pivotal role of interactions between ultraviolet radiation and acetic acid exposure in exacerbating the environmental risks associated with masks, while emphasizing the pronounced influence of many other interactions. The research provides a comprehensive understanding of the intricate aging processes and ensuing environmental risks posed by DFMs, offering valuable insights essential for developing sustainable management strategies in aquatic ecosystems.


Subject(s)
Masks , Ultraviolet Rays , Microplastics/toxicity , Acetic Acid/chemistry , Metals, Heavy/analysis , Sodium Chloride/chemistry , Time Factors , Disposable Equipment , Chromium/chemistry , Chromium/analysis , Adsorption , Environmental Pollutants/toxicity , Tetracycline/chemistry , Tetracycline/analysis
9.
Zhongguo Zhen Jiu ; 44(7): 856-8, 2024 Jul 12.
Article in Chinese | MEDLINE | ID: mdl-38986601

ABSTRACT

A kind of disposable self-destructed and sheath-encased sterile acupuncture needle is designed to efficiently solve the issues of safety and sterilization encountered in the routine operation of acupuncture. The needle consists of three components, i.e. the needle body, the sheath and the locker. The needle body is movable and rotatable in the sheath, but can not be separated from the sheath. It is convenient for the operator to perform the lifting-thrusting and twisting techniques, and to prevent the non-punctured portion of the body from being out off the sheath so that a sterile confined room is formed between the needle and the skin of the operated area. With a locker installed between the sheath and the needle handle, after needle removal, the needle body can be returned and locked in the sheath, avoiding the exposure of needle tip, obtaining the self-destruction of needle and preventing from needling accident and reuse of needle. The devise is operated easily, which is effectively reduce the risk of infection and ensure the safety of medical staffs in practice.


Subject(s)
Acupuncture Therapy , Disposable Equipment , Needles , Acupuncture Therapy/instrumentation , Acupuncture Therapy/methods , Humans , Equipment Design , Sterilization/instrumentation , Sterilization/methods
10.
Biomed Environ Sci ; 37(6): 639-646, 2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38988114

ABSTRACT

Objective: To develop a highly sensitive and rapid nucleic acid detection method for the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Methods: We designed, developed, and manufactured an integrated disposable device for SARS-CoV-2 nucleic acid extraction and detection. The precision of the liquid transfer and temperature control was tested. A comparison between our device and a commercial kit for SARS-Cov-2 nucleic acid extraction was performed using real-time fluorescence reverse transcription polymerase chain reaction (RT-PCR). The entire process, from SARS-CoV-2 nucleic acid extraction to amplification, was evaluated. Results: The precision of the syringe transfer volume was 19.2 ± 1.9 µL (set value was 20), 32.2 ± 1.6 (set value was 30), and 57.2 ± 3.5 (set value was 60). Temperature control in the amplification tube was measured at 60.0 ± 0.0 °C (set value was 60) and 95.1 ± 0.2 °C (set value was 95) respectively. SARS-Cov-2 nucleic acid extraction yield through the device was 7.10 × 10 6 copies/mL, while a commercial kit yielded 2.98 × 10 6 copies/mL. The mean time to complete the entire assay, from SARS-CoV-2 nucleic acid extraction to amplification detection, was 36 min and 45 s. The detection limit for SARS-CoV-2 nucleic acid was 250 copies/mL. Conclusion: The integrated disposable devices may be used for SARS-CoV-2 Point-of-Care test (POCT).


Subject(s)
COVID-19 , Disposable Equipment , RNA, Viral , SARS-CoV-2 , SARS-CoV-2/isolation & purification , COVID-19/diagnosis , COVID-19/virology , Humans , RNA, Viral/isolation & purification , RNA, Viral/analysis , COVID-19 Nucleic Acid Testing/instrumentation , COVID-19 Nucleic Acid Testing/methods , Nucleic Acid Amplification Techniques/instrumentation , Nucleic Acid Amplification Techniques/methods , Real-Time Polymerase Chain Reaction/methods , Real-Time Polymerase Chain Reaction/instrumentation
11.
J Am Acad Orthop Surg ; 32(15): 705-711, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38861714

ABSTRACT

INTRODUCTION: Orthopaedic surgery is culpable, in part, for the excessive carbon emissions in health care partly due to the utilization of disposable instrumentation in most procedures, such as rotator cuff repair (RCR). To address growing concerns about hospital waste, some have considered replacing disposable instrumentation with reusable instrumentation. The purpose of this study was to estimate the cost and carbon footprint of waste disposal of RCR kits that use disposable instrumentation compared with reusable instrumentation. METHODS: The mass of the necessary materials and their packaging to complete a four-anchor RCR from four medical device companies that use disposable instrumentation and one that uses reusable instrumentation were recorded. Using the cost of medical waste disposal at our institution ($0.14 per kilogram) and reported values from the literature for carbon emissions produced from the low-temperature incineration of noninfectious waste (249 kgCO 2 e/t) and infectious waste (569 kgCO 2 e/t), we estimated the waste management cost and carbon footprint of waste disposal produced per RCR kit. RESULTS: The disposable systems of four commercial medical device companies had 783%, 570%, 1,051%, and 478%, respectively, greater mass and waste costs when compared with the reusable system. The cost of waste disposal for the reusable instrumentation system costs on average $0.14 less than the disposable instrumentation systems. The estimated contribution to the overall carbon footprint produced from the disposal of a RCR kit that uses reusable instrumentation was on average 0.37 kg CO2e less than the disposable instrumentation systems. CONCLUSION: According to our analysis, reusable instrumentation in four-anchor RCR leads to decreased waste and waste disposal costs and lower carbon emissions from waste disposal. Additional research should be done to assess the net benefit reusable systems may have on hospitals and the effect this may have on a long-term decrease in carbon footprint. LEVEL OF EVIDENCE: Level II.


Subject(s)
Carbon Footprint , Disposable Equipment , Equipment Reuse , Humans , Disposable Equipment/economics , Equipment Reuse/economics , Medical Waste Disposal , Rotator Cuff Injuries/surgery , Rotator Cuff Injuries/economics , Orthopedic Procedures/instrumentation , Orthopedic Procedures/economics , Suture Anchors , Medical Waste
12.
Surgeon ; 22(4): 236-241, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38862376

ABSTRACT

INTRODUCTION: As hospitals strive to reduce their environmental footprint, there is an ongoing debate over the environmental implications of reusable versus disposable linens in operating rooms (ORs). This research aimed to compare the environmental impact of reusable versus single-use OR bed covers and lift sheets using life cycle assessment (LCA) methodology. METHODS: LCA is an established tool with rigorous methodology that uses science-based processes to measure environmental impact. This study compared the impacts of three independent system scenarios at a single large academic hospital: reusable bed covers with 50 laundry cycles and subsequent landfill disposal (System 1), single-use bed covers with waste landfill disposal (System 2), and single-use bed covers with waste disposal using incineration (System 3). RESULTS: The total carbon footprint of System 1 for 50 uses was 19.83 â€‹kg carbon dioxide equivalents (CO2-eq). System 2 generated 64.99 â€‹kg CO2-eq. For System 3, the total carbon footprint was 108.98 â€‹kg CO2-eq. The raw material extraction for all the material to produce an equivalent 50 single-use OR bed cover kits was tenfold more carbon-intensive than the reusable bed cover. Laundering one reusable OR bed cover 50 times was more carbon intensive (12.12 â€‹kg CO2-eq) than landfill disposal of 50 single-use OR bed covers (2.52 â€‹kg CO2-eq). DISCUSSION: Our analysis demonstrates that one reusable fabric-based OR bed cover laundered 50 times, despite the carbon and water-intensive laundering process, exhibits a markedly lower carbon footprint than its single-use counterparts. The net difference is 45.16 â€‹kg CO2-eq, equivalent to driving 115 miles in an average gasoline-powered passenger vehicle. This stark contrast underscores the efficacy of adopting reusable solutions to mitigate environmental impact within healthcare facilities.


Subject(s)
Carbon Footprint , Equipment Reuse , Operating Rooms , Humans , Bedding and Linens , Disposable Equipment , Environment , Recycling
13.
Obes Surg ; 34(7): 2553-2561, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38822904

ABSTRACT

BACKGROUND: Bariatric surgery patients may develop common bile duct stones, and the alterations in their anatomy present challenges in treating this condition. Methods such as laparoscopic bile duct exploration is impractical in many healthcare facilities, due to the absence of a choledochoscope. This study assesses the feasibility of laparoscopic exploration of the common bile duct using a disposable bronchoscope in these individuals. METHOD: The study involved 32 participants who had undergone gastric bypass surgery. These participants presented with both bile duct stones and bile ducts exceeding 8 mm in diameter, diagnosed through either MRCP or cholangiography conducted during the surgery. Stone extraction was carried out through either choledotomy or transcystic routes using a disposable bronchoscope and endoscopic baskets. RESULTS: The patients' ages ranged from 27 to 66 years, with a mean bile duct diameter of 11.6 mm (SD 3.1 mm). A 100% stone clearance rate was achieved for all patients. None of the patients required conversion to open surgery. No T-tubes were placed. One patient developed biloma and intra-abdominal abscesses, which were successfully treated with a percutaneous drain over the course of a week. No mortalities were recorded during the course of this study. CONCLUSION: Our study results demonstrate that laparoscopic bile duct exploration is both feasible and safe in patients who have undergone gastric bypass surgery. The utilization of a disposable bronchoscope emerges as a practical and cost-effective alternative to a choledochoscope in this procedure.


Subject(s)
Disposable Equipment , Feasibility Studies , Gallstones , Gastric Bypass , Laparoscopy , Obesity, Morbid , Humans , Middle Aged , Female , Adult , Male , Gastric Bypass/methods , Aged , Laparoscopy/methods , Obesity, Morbid/surgery , Gallstones/surgery , Bronchoscopes , Treatment Outcome , Common Bile Duct/surgery
16.
Pan Afr Med J ; 47: 145, 2024.
Article in English | MEDLINE | ID: mdl-38933433

ABSTRACT

Human immunodeficiency virus prevalence was increasing worldwide. Medication-associated urinary calculi are very commonly caused by medications used to treat HIV-positive patients. We present a case of an HIV-positive 39-year-old male with ureteral stent encrustation and kidney stone. Ureterolithotripsy using a disposable flexible ureteroscope is performed. The postoperative evolution was favorable. The disposable flexible ureteroscope is effective in the treatment of HIV combined with ureteral stent encrustation.


Subject(s)
HIV Infections , Kidney Calculi , Lithotripsy , Stents , Ureteroscopy , Humans , Male , Adult , HIV Infections/complications , Stents/adverse effects , Ureteroscopes , Kidney Calculi/diagnostic imaging , Kidney Calculi/surgery , Lithotripsy/adverse effects , Lithotripsy/methods , Ureteroscopy/adverse effects , Disposable Equipment , Laparoscopy , Tomography, X-Ray Computed , Treatment Outcome
17.
BMC Urol ; 24(1): 126, 2024 Jun 14.
Article in English | MEDLINE | ID: mdl-38877524

ABSTRACT

PURPOSE: Circumcision is the most common surgical procedures performed in males. Medical circumcision is recommended for diseases such as phimosis, paraphimosis, balanoposthitis and common urinary tract infections, although there is no exact indication. Conversely, Jewish and Muslim individuals commonly undergo circumcision regardless of medical necessity. Circumcision devices are designed to shorten surgery time, achieve an aesthetic appearance and ensure safe surgery. The aim of this study is to evaluate the effectiveness of the NeoAlis clamp, a disposable circumcision device, by comparing it with the sleeve technique in children. MATERIALS AND METHODS: Between 2017 and 2023, retrospective evaluation of 2626 patients who underwent circumcision using either the NeoAlis clamp (group 1) or the sleeve technique (group 2) was conducted. Operation time, results, cost, complications were compared between the two groups. RESULTS: The study encompassed 2626 patients who fulfilled the inclusion criteria. Group 1 comprised 2403 patients, whereas Group 2 consisted of 223 patients. The overall complication rate, as denoted by n = 47, was 1.7%. Group 1 operation time was shorter than group 2. Bleeding, the most feared complication in the early period, was higher in the second group. No statistically significant difference was observed between the two groups regarding cost comparison. CONCLUSION: The primary concern during circumcision is to avoid complications related to general anesthesia in newborns and infants. The use of disposable ring devices has been facilitated by the shorter operation time and the absence of the need for sutures when performing circumcision under local anesthesia. However, knowledge of advanced surgical circumcision techniques is necessary in cases of bleeding and inappropriate ring placement.


Subject(s)
Circumcision, Male , Disposable Equipment , Equipment Design , Circumcision, Male/instrumentation , Circumcision, Male/adverse effects , Circumcision, Male/methods , Humans , Male , Retrospective Studies , Child , Child, Preschool , Infant , Operative Time , Adolescent , Postoperative Complications/epidemiology , Postoperative Complications/prevention & control
18.
Surg Endosc ; 38(6): 3361-3367, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38710887

ABSTRACT

INTRODUCTION: Disposable duodenoscopes and duodenoscopes with disposable endcaps are being used in clinical practice to reduce or eliminate the risk of transmitting infections. The study aim was to assess perceptions and experiences regarding the use of these duodenoscopes among advanced endoscopy fellows in a nationally representative sample. METHODS: A 17-item electronic survey was sent to 74 advanced endoscopy training programs. The survey was completed by 50 participants and their responses were included for analysis. RESULTS: Most participants were from academic training programs (82.7%) and identified as being in their 7th year of post graduate training (92%; PGY-7). Participants performed an average of 414 ERCPs. 29% reported difficulty with cannulation using disposable duodenoscopes versus 15.7% with duodenoscopes with disposable endcaps (vs. standard duodenoscope). 96% of trainees perceived disposable duodenoscopes as not cost effective and 92% stated they would not use this device during independent practice. 100% of trainees stated that they would use duodenoscopes with disposable endcaps during independent practice. For their most challenging cases, 90% of trainees preferred using standard reprocessable duodenoscopes while no trainee indicated they would prefer using a disposable duodenoscope in this scenario. 82% of participants stated that disposable duodenoscopes and disposable endcaps should be used exclusively or preferentially for high-risk patients citing cost, functionality, and concerns regarding environmental impact. DISCUSSION: Advanced endoscopy fellows perceive disposable duodenoscopes as impacting technical maneuverability. Concerns about functionality, cost effectiveness and environmental impact are barriers to adoption.


Subject(s)
Disposable Equipment , Duodenoscopes , Disposable Equipment/economics , Humans , Attitude of Health Personnel , Surveys and Questionnaires , Cholangiopancreatography, Endoscopic Retrograde , Internship and Residency , United States
20.
Georgian Med News ; (348): 44-46, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38807389

ABSTRACT

This research aims to characterize efficiency of a flexible ureteroscope that is of single use with regard to surgical time, absence of stone, and complications. From March 2022 to April 2023, the Basrah Urological Centre carried out this anticipated work. After excluding patients with untreated urinary tract infections, excessive blood urea, and ureteral strictures, the study involved ninety-eight patients. All patients were above 20 years of age. Patients were operated on by the same surgeon. This study involved 108 patients in this study composed of 42 (39.8%) men and 65 (60.2%) women. With a standard deviation of 10.9 years, the patient's mean age was 39.2 years. The total stone burden ranged from 6.9 to 14.5 mm, averaging 9.7±2.9 mm. The stone density ranged from 820-1411 HU, averaging 1000.8±279.3 HU. According to the current study, treating renal stones with a single-use flexible ureteroscope is less complicated and more successful.


Subject(s)
Kidney Calculi , Lithotripsy , Ureteroscopes , Humans , Female , Male , Adult , Kidney Calculi/surgery , Kidney Calculi/therapy , Lithotripsy/instrumentation , Lithotripsy/methods , Middle Aged , Disposable Equipment , Ureteroscopy/instrumentation , Ureteroscopy/methods , Operative Time
SELECTION OF CITATIONS
SEARCH DETAIL