Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 14.100
Filter
1.
J Vis Exp ; (208)2024 Jun 28.
Article in English | MEDLINE | ID: mdl-39007558

ABSTRACT

Detailed study of non-failing human hearts rejected for transplantation provides a unique opportunity to perform structural analyses across microscopic and macroscopic scales. These techniques include tissue clearing (modified immunolabeling-enabled three-dimensional (3D) imaging of solvent-cleared organs) and immunohistochemical staining. Mesoscopic examination procedures include stereoscopic dissection and micro-computed tomographic (CT) scanning. Macroscopic examination procedures include gross dissection, photography (including anaglyphs and photogrammetry), CT, and 3D printing of the physically or virtually dissected or whole heart. Before macroscopic examination, pressure-perfusion fixation may be performed to maintain the 3D architecture and physiologically relevant morphology of the heart. The application of these techniques in combination to study the human heart is unique and crucial in understanding the relationship between distinct anatomic features such as coronary vasculature and myocardial innervation in the context of the 3D architecture of the heart. This protocol describes the methodologies in detail and includes representative results to illustrate progress in the research of human cardiac anatomy.


Subject(s)
Heart , Imaging, Three-Dimensional , Humans , Heart/anatomy & histology , Heart/diagnostic imaging , Imaging, Three-Dimensional/methods , X-Ray Microtomography/methods , Dissection/methods , Printing, Three-Dimensional
2.
BMC Med Educ ; 24(1): 718, 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38961382

ABSTRACT

BACKGROUND: The anatomy dissection course is a major part of the first two years of the traditional medical curriculum in Germany. The vast amount of content to be learned and the repeated examination is unanimously perceived by students and teachers as a major stress factor that contributes to the increase of psychosocial stress during the first two years of the course of study. Published interventions for specific stress reduction are scarce. METHODS: In a randomized, controlled design two intervention groups were compared with a control group (CG) over the whole dissection course (nine measuring points before, during and after first and second semester). The 'Stress Management intervention (IVSM)' targeted at the setting of personal standards, the 'Friendly Feedback intervention (IVFF)' at the context of frequent testing. Quantitative surveys were distributed at nine measuring points. The questionnaire comprised validated instruments and self-developed items regarding stress, positive and negative affect, anxiety, intrinsic and extrinsic motivation, self-efficacy, and perceived performance. RESULTS: Out of 195 students inscribed in the dissection course, 166 (85%) agreed to participate in the study. The experience of stress during the dissection course was significantly higher in the CG than in the IVFF. Anxiety and negative affect were lower in students of the IVFF while positive affect, intrinsic motivation, and self-efficacy were higher than in the CG. For anxiety and negative affect in the IVSM this was especially seen at the end of the second semester. The self-perceived increase in both knowledge and preparedness for the first big oral and written examination did not differ between the study groups. About three quarters of the participants would choose the intervention 'Friendly Feedback' if given the choice. CONCLUSIONS: Replacing formal tests with friendly feedback has proven to be an effective measure to reduce stress and negative affect and foster positive affect, self-efficacy, and intrinsic motivation, while it did not impair self-perceived academic performance.


Subject(s)
Anatomy , Educational Measurement , Motivation , Students, Medical , Humans , Female , Male , Students, Medical/psychology , Germany , Anatomy/education , Stress, Psychological , Trust , Education, Medical, Undergraduate , Dissection/education , Adult , Curriculum , Young Adult , Self Efficacy , Surveys and Questionnaires , Teaching
3.
Acta Neurochir (Wien) ; 166(1): 298, 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-39009772

ABSTRACT

BACKGROUND: Resection of the medial wall of the cavernous sinus (MWCSR) is a growing surgical maneuver for the radical removal of pituitary adenomas. METHOD: We present a simple modification of the technique following the two dural layers of the floor of the sella turcica, allowing for early identification of the medial wall and simplifying dissection. We support this technique with an anatomical analysis on cadaveric specimens and clarifying dissection images. CONCLUSION: Recognition and dissection of the dural unfolding of the floor of the sella turcica are "key points" that lower the risk and facilitate the MWCSR.


Subject(s)
Cavernous Sinus , Pituitary Neoplasms , Sella Turcica , Cavernous Sinus/surgery , Humans , Pituitary Neoplasms/surgery , Pituitary Neoplasms/pathology , Pituitary Neoplasms/diagnostic imaging , Sella Turcica/surgery , Adenoma/surgery , Adenoma/pathology , Cadaver , Neurosurgical Procedures/methods , Neuroendoscopy/methods , Endoscopy/methods , Dissection/methods
4.
MedEdPORTAL ; 20: 11406, 2024.
Article in English | MEDLINE | ID: mdl-38957530

ABSTRACT

Introduction: As surgical technologies grow, so too do demands on surgical trainees to master increasing numbers of skill sets. With the rise of endovascular surgery, trainees have fewer opportunities to practice open vascular techniques in the operating room. Simulation can bridge this gap. However, existing published open vascular simulation curricula are basic or based on expensive models. Methods: We iteratively developed an open vascular skills curriculum for second-year surgery residents comprising six 2-hour sessions. We refined the curriculum based on feedback from learners and faculty. The curriculum required skilled facilitators, vascular instruments, and tissue models. We evaluated the latest iteration with a survey and by assessing participants' technical skills using the Objective Structured Assessment of Technical Skills (OSATS) form. Results: Over the past 10 years, 101 residents have participated in the curriculum. Nine of 13 residents who participated in the latest curricular iteration completed the survey. All respondents rated the sessions as excellent and strongly agreed that they had improved their abilities to perform anastomoses with tissue and prosthetic. Facilitators completed 18 OSATS forms for residents in the fifth and sixth sessions of the latest iteration. Residents scored well overall, with a median 26.5 (interquartile range: 24-29) out of a possible score of 35, with highest scores on knowledge of instruments. Discussion: This simulation-based curriculum facilitates open vascular surgical skill acquisition among surgery residents. The curriculum allows residents to acquire critical vascular skills that are challenging to learn in an increasingly demanding operative setting.


Subject(s)
Clinical Competence , Curriculum , Internship and Residency , Simulation Training , Humans , Internship and Residency/methods , Simulation Training/methods , Surveys and Questionnaires , Vascular Surgical Procedures/education , Anastomosis, Surgical/education , Dissection/education , Education, Medical, Graduate/methods , Educational Measurement
5.
Sci Rep ; 14(1): 16388, 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-39014004

ABSTRACT

In recent years, human anatomy education has faced challenges with traditional donor dissection, leading to the emergence of virtual dissection as an alternative. This study aims to investigate the academic performance and satisfaction of medical students by comparing the virtual and donor dissections. An open-labeled crossover randomized controlled trial was conducted with 154 first-year medical students in Human Anatomy and Neuroanatomy laboratories, which were divided into three classes. Students were randomly assigned to either the virtual (virtual dissection followed by donor dissection) or donor (donor dissection followed by virtual dissection) groups in each class. A curriculum, incorporating head-mounted displays (HMDs), a life-sized touchscreen, and tablets, was developed. Data was evaluated through quizzes and surveys. In the Human Anatomy laboratory, each class of the donor group conducted heart extraction, dissection and observation. In observation class, the virtual group had a significantly higher mean quiz score than the donor group (p < 0.05). Compared to the donor, satisfaction was significantly higher for the HMD (understanding of concept and immersion), life-size touchscreen (esthetics, understanding of the concept, and spatial ability), and tablet (esthetics, understanding of the concept, spatial ability, and continuous use intention). In the Neuroanatomy laboratory, the virtual group showed significantly higher mean quiz scores than the donor group (p < 0.05), and tablet showed a significantly higher satisfaction than donor in terms of esthetics, understanding of the concept, and spatial ability. These results suggest that virtual dissection has the potential to supplement or replace donor dissection in anatomy education. This study is innovative in that it successfully delivered scenario-based virtual content and validated the efficacy in academic performance and satisfaction when using virtual devices compared to donor.Trial registration: This research has been registered in the Clinical Research Information Service (CRIS, https://cris.nih.go.kr/cris/search/detailSearch.do?search_lang=E&focus=reset_12&search_page=L&pageSize=10&page=undefined&seq=26002&status=5&seq_group=26002 ) with registration number "KCT0009075" and registration date "27/12/2023".


Subject(s)
Dissection , Humans , Female , Male , Dissection/methods , Anatomy/education , Students, Medical/psychology , Young Adult , Personal Satisfaction , Adult , Cross-Over Studies , Curriculum
6.
J Robot Surg ; 18(1): 245, 2024 Jun 07.
Article in English | MEDLINE | ID: mdl-38847926

ABSTRACT

Previously, our group established a surgical gesture classification system that deconstructs robotic tissue dissection into basic surgical maneuvers. Here, we evaluate gestures by correlating the metric with surgeon experience and technical skill assessment scores in the apical dissection (AD) of robotic-assisted radical prostatectomy (RARP). Additionally, we explore the association between AD performance and early continence recovery following RARP. 78 AD surgical videos from 2016 to 2018 across two international institutions were included. Surgeons were grouped by median robotic caseload (range 80-5,800 cases): less experienced group (< 475 cases) and more experienced (≥ 475 cases). Videos were decoded with gestures and assessed using Dissection Assessment for Robotic Technique (DART). Statistical findings revealed more experienced surgeons (n = 10) used greater proportions of cold cut (p = 0.008) and smaller proportions of peel/push, spread, and two-hand spread (p < 0.05) than less experienced surgeons (n = 10). Correlations between gestures and technical skills assessments ranged from - 0.397 to 0.316 (p < 0.05). Surgeons utilizing more retraction gestures had lower total DART scores (p < 0.01), suggesting less dissection proficiency. Those who used more gestures and spent more time per gesture had lower efficiency scores (p < 0.01). More coagulation and hook gestures were found in cases of patients with continence recovery compared to those with ongoing incontinence (p < 0.04). Gestures performed during AD vary based on surgeon experience level and patient continence recovery duration. Significant correlations were demonstrated between gestures and dissection technical skills. Gestures can serve as a novel method to objectively evaluate dissection performance and anticipate outcomes.


Subject(s)
Clinical Competence , Dissection , Prostatectomy , Robotic Surgical Procedures , Prostatectomy/methods , Humans , Robotic Surgical Procedures/methods , Male , Dissection/methods , Gestures , Prostatic Neoplasms/surgery , Surgeons
7.
Zhonghua Wei Chang Wai Ke Za Zhi ; 27(6): 630-633, 2024 Jun 25.
Article in Chinese | MEDLINE | ID: mdl-38901999

ABSTRACT

Objective: This report presents the initial outcomes of endoscopic intermuscular dissection (EID), a novel technique introduced by our team for the diagnostic resection of early rectal cancer, focusing on the postoperative status of the vertical margins. Methods: On January 26, 2024, a patient with early rectal cancer (cT1-2N0M0) underwent Endoscopic Intermuscular Dissection. The EID procedure consists of six steps: (1) mucosal incision; (2) submucosal dissection; (3) superficial muscular layer incision; (4) intermuscular dissection; (5) complete tumor removal; (6) wound management. Results: The patient was a 70-year-old male with rectal cancer (cT1-2N0M0). The tumor was located on the left anterior wall of the rectum, approximately 9 cm from the anal margin, and measured 20mm in size. The dissection rate was 2.68 mm²/minute, and the total duration of the surgery was 109 minutes. The patient was successfully discharged on the fifth day after surgery. Pathological examination of the post-endoscopic surgery specimen revealed pT1b, with negative vertical margins. Follow-up after more than one month showed good recovery with no complications such as bleeding, perforation, infection, or stricture occurring. Colonoscopy indicated the presence of a granulation tissue suggestive of inflammation. Conclusion: Endoscopic Intermuscular Dissection for the diagnostic resection of early rectal cancer is potentially safe and may achieve negative vertical margins.


Subject(s)
Rectal Neoplasms , Humans , Rectal Neoplasms/surgery , Rectal Neoplasms/diagnosis , Aged , Male , Endoscopic Mucosal Resection/methods , Dissection/methods , Rectum/surgery
8.
Elife ; 122024 Jun 19.
Article in English | MEDLINE | ID: mdl-38896568

ABSTRACT

We present open-source tools for three-dimensional (3D) analysis of photographs of dissected slices of human brains, which are routinely acquired in brain banks but seldom used for quantitative analysis. Our tools can: (1) 3D reconstruct a volume from the photographs and, optionally, a surface scan; and (2) produce a high-resolution 3D segmentation into 11 brain regions per hemisphere (22 in total), independently of the slice thickness. Our tools can be used as a substitute for ex vivo magnetic resonance imaging (MRI), which requires access to an MRI scanner, ex vivo scanning expertise, and considerable financial resources. We tested our tools on synthetic and real data from two NIH Alzheimer's Disease Research Centers. The results show that our methodology yields accurate 3D reconstructions, segmentations, and volumetric measurements that are highly correlated to those from MRI. Our method also detects expected differences between post mortem confirmed Alzheimer's disease cases and controls. The tools are available in our widespread neuroimaging suite 'FreeSurfer' (https://surfer.nmr.mgh.harvard.edu/fswiki/PhotoTools).


Every year, thousands of human brains are donated to science. These brains are used to study normal aging, as well as neurological diseases like Alzheimer's or Parkinson's. Donated brains usually go to 'brain banks', institutions where the brains are dissected to extract tissues relevant to different diseases. During this process, it is routine to take photographs of brain slices for archiving purposes. Often, studies of dead brains rely on qualitative observations, such as 'the hippocampus displays some atrophy', rather than concrete 'numerical' measurements. This is because the gold standard to take three-dimensional measurements of the brain is magnetic resonance imaging (MRI), which is an expensive technique that requires high expertise ­ especially with dead brains. The lack of quantitative data means it is not always straightforward to study certain conditions. To bridge this gap, Gazula et al. have developed an openly available software that can build three-dimensional reconstructions of dead brains based on photographs of brain slices. The software can also use machine learning methods to automatically extract different brain regions from the three-dimensional reconstructions and measure their size. These data can be used to take precise quantitative measurements that can be used to better describe how different conditions lead to changes in the brain, such as atrophy (reduced volume of one or more brain regions). The researchers assessed the accuracy of the method in two ways. First, they digitally sliced MRI-scanned brains and used the software to compute the sizes of different structures based on these synthetic data, comparing the results to the known sizes. Second, they used brains for which both MRI data and dissection photographs existed and compared the measurements taken by the software to the measurements obtained with MRI images. Gazula et al. show that, as long as the photographs satisfy some basic conditions, they can provide good estimates of the sizes of many brain structures. The tools developed by Gazula et al. are publicly available as part of FreeSurfer, a widespread neuroimaging software that can be used by any researcher working at a brain bank. This will allow brain banks to obtain accurate measurements of dead brains, allowing them to cheaply perform quantitative studies of brain structures, which could lead to new findings relating to neurodegenerative diseases.


Subject(s)
Alzheimer Disease , Brain , Imaging, Three-Dimensional , Machine Learning , Humans , Imaging, Three-Dimensional/methods , Alzheimer Disease/diagnostic imaging , Alzheimer Disease/pathology , Brain/diagnostic imaging , Brain/pathology , Photography/methods , Dissection , Magnetic Resonance Imaging/methods , Neuropathology/methods , Neuroimaging/methods
9.
Surg Radiol Anat ; 46(8): 1373-1378, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38858313

ABSTRACT

PURPOSE: In the existing literature, various insertion variations and classifications for the Pectoralis Minor (PMi) muscle have been reported. However, there is limited information on inferior origin variations of the PMi muscles and a certain classification is lacking. CASE PRESENTATION: During routine cadaver dissection of an adult male, variations in the origin of the bilateral PMi muscles were identified. Morphometric measurements of the PMi were conducted using ImageJ software, and the unusual origin patterns of the PMi were categorized into specific types. The PMi muscle demonstrated a bilateral variations. On the right side, the PMi displays a bifid structure comprising medial and lateral fibers. The left PMi originate from the superolateral margins of the 4th to 6th costae and terminate at the anterosuperior surface of the coracoid process. The length of the right medial fiber before merging was 5.67 ± 0.04 cm, while that of the right lateral fiber was 6.68 ± 0.05 cm. The distance between the two fibers was measured as 0.43 cm, with a length of 3.33 ± 0.02 cm. The length and diameter of the muscle fibers extending to the 6th costa were 2.63 ± 0.01 cm and 0.46 cm, respectively. CONCLUSIONS: Potential variations in PMi arising from impairment during development may occasionally manifest as asymptomatic conditions or predispose individuals to shoulder impingement, rotator cuff dysfunction, shoulder-related disorders, and functional impairments. Therefore, careful attention to this variation is considered in surgical planning.


Subject(s)
Anatomic Variation , Cadaver , Pectoralis Muscles , Humans , Pectoralis Muscles/abnormalities , Male , Dissection
10.
Surg Radiol Anat ; 46(8): 1331-1344, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38871860

ABSTRACT

BACKGROUND: Performing transopercular frontal approaches to the insula, widely used in glioma surgeries, necessitates a meticulous understanding of both cortical and subcortical neuroanatomy. This precision is vital for preserving essential structures and accurately interpreting the results of direct electrical stimulation. Nevertheless, acquiring a compelling mental image of the anatomy of this region can be challenging due to several factors, among which stand out its complexity and the fact that white matter fasciculi are imperceptible to the naked eye in the living brain. AIM: In an effort to optimize the study of the anatomy relevant to this topic, we performed a procedure-guided laboratory study using subpial dissection, fiber dissection, vascular coloration, and stereoscopic photography in a "real-life" surgical perspective. METHODS: Nine cerebral specimens obtained from body donation were extracted and fixed in formalin. Colored silicone injection and a variant of Klinglers's technique were used to demonstrate vascular and white matter structures, respectively. We dissected and photographed the specimens in a supero-antero-lateral view to reproduce the surgeon's viewpoint. The anatomy related to the development of the surgical corridor and resection cavity was documented using both standard photography and the red-cyan anaglyph technique. RESULTS: The anatomy of frontal transopercular approaches to the insula involved elements of different natures-leptomeningeal, cortical, vascular, and fascicular-combining in the surgical field in a complex disposition. The disposition of these structures was successfully demonstrated through the aforementioned anatomical techniques. Among the main structures in or around the surgical corridor, the orbital, triangular, and opercular portions of the inferior frontal gyrus are critical landmarks in the cortical stage, as well as the leptomeninges of the Sylvian fissure and the M2-M4 branches of the middle cerebral artery in the subpial dissection stage, and the inferior fronto-occipital, uncinate and arcuate fasciculi, and the corona radiata in establishing the deep limits of resection. CONCLUSIONS: Procedure-guided study of cerebral hemispheres associating subpial, vascular, and fiber dissection from a surgical standpoint is a powerful tool for the realistic study of the surgical anatomy relevant to frontal transopercular approaches to the insula.


Subject(s)
Cadaver , Cerebral Cortex , Dissection , Humans , Cerebral Cortex/anatomy & histology , Cerebral Cortex/diagnostic imaging , Cerebral Cortex/surgery , Neurosurgical Procedures/methods , Male , Female , Glioma/surgery , Brain Neoplasms/surgery , Brain Neoplasms/diagnostic imaging
11.
Surg Radiol Anat ; 46(8): 1185-1187, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38888833

ABSTRACT

Agenesis of the left hepatic lobe is a rare anomaly described as the absence of liver tissue on the left side of the gallbladder fossa or falciform ligament. Here we report a case of agenesis of the left hepatic lobe identified during educational dissection of an 84-year-old male formalin-fixed cadaver. The gross anatomical characteristics, embryological origin, and clinical relevance of this rare variation are described in this report.


Subject(s)
Anatomic Variation , Cadaver , Liver , Humans , Male , Liver/abnormalities , Aged, 80 and over , Dissection
12.
Medicina (Kaunas) ; 60(6)2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38929611

ABSTRACT

Background: Few original articles describe the perioperative outcomes of uniportal thoracoscopic segmentectomy using a unidirectional dissection approach. In this retrospective study, we evaluated the feasibility and safety of this procedure. Methods: This study included 119 patients who underwent uniportal thoracoscopic segmentectomy in our department between February 2019 and December 2022. The patients were divided into unidirectional (group U, n = 28) and conventional (group C, n = 91) dissection approach groups. While the dominant pulmonary vessels and bronchi were transected at the hilum without dissecting a fissure in the unidirectional (U) group, the dominant pulmonary artery was exposed and divided at a fissure in the conventional (C) group. Patient characteristics and perioperative outcomes were compared between groups U and C. Results: The proportions of simple and complex segmentectomies were statistically similar between the groups. The operating time was shorter (group U: 110 [interqurtile range: 90-140] min, group C: 135 [interqurtile range: 105-166] min, p = 0.012) and there was less blood loss (group U: 0 [interqurtile range: 0-0] g, group C: 0 [interqurtile range: 0-50] g, p = 0.003) in group U than in group C. However, there were no significant intergroup differences in other perioperative outcomes. Conclusions: The unidirectional dissection approach in uniportal thoracoscopic pulmonary segmentectomy is safe and feasible and enables a smoother operation.


Subject(s)
Feasibility Studies , Lung Neoplasms , Pneumonectomy , Thoracic Surgery, Video-Assisted , Humans , Female , Male , Retrospective Studies , Middle Aged , Aged , Pneumonectomy/methods , Pneumonectomy/instrumentation , Pneumonectomy/adverse effects , Lung Neoplasms/surgery , Thoracic Surgery, Video-Assisted/methods , Thoracic Surgery, Video-Assisted/instrumentation , Operative Time , Dissection/methods , Dissection/instrumentation , Thoracoscopy/methods , Adult , Blood Loss, Surgical/statistics & numerical data , Treatment Outcome
13.
Surg Radiol Anat ; 46(8): 1279-1283, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38874604

ABSTRACT

The thyrohyoid muscle belongs to the infrahyoid group located in the carotid triangle. It normally originates from thyroid cartilage and inserts into hyoid bone. Quite often, it is continuous with the sternohyoid muscle. Furthermore, there are variants that have their origin in the cricoid cartilage only, however, this occurs very rarely. During anatomical dissection, a two-headed variant of this muscle was found. One head had its origin in the cricoid cartilage and the other in the thyroid cartilage. This variant of thyrohyoid had not been previously described in the available literature. Therefore, we believe that it may be referred to as the cricothyrohyoid muscle. As the thyrohyoideus is often used as a landmark during surgical procedures in the prelaryngeal area and as a muscle graft, a thorough knowledge of its anatomy and variation is extremely important. We speculate that the two-headed version of this muscle may be problematic during surgical procedures in this region, however, it may also provide more options as a muscular graft.


Subject(s)
Anatomic Variation , Humans , Cadaver , Thyroid Cartilage/anatomy & histology , Thyroid Cartilage/surgery , Laryngeal Muscles/anatomy & histology , Laryngeal Muscles/surgery , Male , Dissection , Neck Muscles/anatomy & histology , Neck Muscles/surgery , Hyoid Bone/anatomy & histology , Hyoid Bone/surgery , Female , Cricoid Cartilage/anatomy & histology , Cricoid Cartilage/surgery
14.
Balkan Med J ; 41(4): 280-285, 2024 07 05.
Article in English | MEDLINE | ID: mdl-38856010

ABSTRACT

Background: Although several surgical landmarks have been proposed to localize the recurrent laryngeal nerve (RLN), there is still no reliable landmark. Aims: To validate the reliability of a novel reference point at the intersection of the inferior border of the cricopharyngeal muscle and the inferior cornu of thyroid cartilage for locating the RLN. Study Design: Cadaver dissection study in the academic department of otolaryngology-head and neck surgery. Methods: Sixty-four RLNs in cadavers were assessed, and measurements of different surgical landmarks in conjunction with the proposed surgical landmark were obtained. Descriptive statistics, Pearson's chi-squared test, and Student's t-test were performed to analyze the data using GraphPad Prism (version 9.4.1; Dotmatics, Boston, Massachusetts, USA). Results: The average distance from the proposed landmark to the RLN was 2.3 ± 0.85 mm. The RLN was located just posterior to the reference point in 95.31% of the cadavers. The RLN passed under the inferior constrictor muscle in 90.63% of the cadavers. There was no statistically significant difference between right- and left-sided RLNs in terms of their relation with the reference point. Conclusion: The proposed reference point can be used as a reliable landmark to locate the RLN. This reference point may help surgeons during difficult thyroidectomy surgeries by providing an additional anatomical landmark.


Subject(s)
Cadaver , Recurrent Laryngeal Nerve , Humans , Recurrent Laryngeal Nerve/anatomy & histology , Recurrent Laryngeal Nerve/surgery , Recurrent Laryngeal Nerve/abnormalities , Male , Female , Anatomic Landmarks , Aged , Reproducibility of Results , Dissection/methods
15.
Bratisl Lek Listy ; 125(7): 450-456, 2024.
Article in English | MEDLINE | ID: mdl-38943507

ABSTRACT

OBJECTIVE: This study aimed to assess the perceived need among surgical residents to revisit their anatomical knowledge and evaluate their attitude towards integrating clinical anatomists into surgical residency program curriculum. BACKGROUND: While medical students learn human anatomy during undergraduate years, the practical application of clinically oriented anatomy becomes vital in surgical specialties. However, this aspect has not been adequately addressed in Indian surgical residency programs. METHODS: An 11-item questionnaire, including closed-ended and Likert-scale questions, was administered to 153 surgical residents. Consent was obtained, and responses were collected via Google Forms. RESULTS: Half of the respondents (50%) felt confident in their self-directed anatomy learning, but 87% believed integrating clinical anatomists would enhance their surgical expertise. Additionally, 88% saw value in revisiting cadaveric dissection. Third-year residents showed a significantly higher inclination towards cadaveric dissection. Deficiencies in the curriculum and time constraints were identified as major barriers. CONCLUSION: The study highlights a perceived need among surgical residents to augment their anatomical knowledge, advocating for the integration of clinical anatomists and cadaveric dissection into training. A collaborative approach, emphasizing both horizontal and vertical integration of anatomy, is recommended to enhance surgical education and practice. (Tab. 4, Fig. 1, Ref. 25).


Subject(s)
Anatomy , Curriculum , Internship and Residency , Humans , Anatomy/education , Surveys and Questionnaires , Anatomists , India , Female , Male , Surgeons/education , Dissection/education , Attitude of Health Personnel , General Surgery/education
16.
Br J Oral Maxillofac Surg ; 62(6): 542-544, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38834495

ABSTRACT

The transconjunctival approach, first described by Bourqet in 1923, has become a routine procedure for the management of fractures of the orbital floor, medial and lateral walls, and infraorbital rim. It is also used in aesthetic surgery and access surgery. Different approaches of transconjunctival surgery, however, can be complicated by the complex lower lid anatomy. In this publication we revisit the anatomy of the transconjunctival approach, and discuss the surgical steps for preseptal and postseptal dissection. We introduce the concept of interseptal space (potential space), its anatomy first described in 1991.


Subject(s)
Conjunctiva , Orbital Fractures , Humans , Conjunctiva/anatomy & histology , Conjunctiva/surgery , Orbital Fractures/surgery , Eyelids/anatomy & histology , Eyelids/surgery , Orbit/anatomy & histology , Orbit/surgery , Dissection/methods
17.
Asian J Endosc Surg ; 17(2): e13277, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38899511

ABSTRACT

INTRODUCTION: During laparoscopic cholecystectomy for acute cholecystitis, it is often difficult to keep the surgical view dry because of inflammation-related tissue fragility and susceptibility to bleeding. The resulting inadequate surgical view can lead to bile duct or vascular injury. Soft coagulation systems are used to achieve hemostasis during various surgeries; however, the usefulness of soft coagulation during laparoscopic cholecystectomy for acute cholecystitis is unclear. We here demonstrate the usefulness and feasibility of blunt dissection and soft coagulation during this procedure. MATERIALS AND SURGICAL TECHNIQUE: We used blunt dissection and soft coagulation when performing laparoscopic cholecystectomy on two patients with acute cholecystitis. As with conventional laparoscopic cholecystectomy, four ports were inserted. After cutting the serosa by electrocautery, blunt dissection using soft coagulation was performed, exposing the inner subserosa. Maintaining this layer using blunt dissection with soft coagulation achieved a sufficiently clear view for safety. After resecting the cystic artery and duct, the gallbladder bed was also dissected by blunt dissection with soft coagulation. Blood loss was <20 mL in both patients. DISCUSSION: Blunt dissection with soft coagulation may be a useful and feasible means of keeping the surgical view dry and minimizing blood loss during laparoscopic cholecystectomy for acute cholecystitis.


Subject(s)
Cholecystectomy, Laparoscopic , Cholecystitis, Acute , Dissection , Electrocoagulation , Humans , Cholecystectomy, Laparoscopic/methods , Cholecystitis, Acute/surgery , Electrocoagulation/methods , Dissection/methods , Female , Male , Middle Aged , Feasibility Studies , Aged , Hemostasis, Surgical/methods , Adult
18.
Langenbecks Arch Surg ; 409(1): 171, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38829557

ABSTRACT

PURPOSE: We describe details and outcomes of a novel technique for optimizing the surgical field during robotic distal pancreatectomy (RDP) for distal pancreatic lesions, which has become common with potential advantages over laparoscopic surgery. METHODS: For suprapancreatic lymph node dissection and splenic artery ligation, we used the basic center position with a scope through the midline port. During manipulation of the perisplenic area, the left position was used by moving the scope to the left medial side. The left lateral position is optionally used by moving the scope to the left lateral port when scope access to the perisplenic area is difficult. In addition, early splenic artery clipping and short gastric artery dissection for inflow block were performed to minimize bleeding around the spleen. We evaluated retrospectively the surgical outcomes of our method using a scoring system that allocated one point for blood inflow control and one point for optimizing the surgical view in the left position. RESULTS: We analyzed 34 patients who underwent RDP or R-radical antegrade modular pancreatosplenectomy (RAMPS). The left position was applied in 14 patients, and the left lateral position was applied in 6. Based on the scoring system, only the 0-point group (n = 8) had four bleeding cases (50%) with splenic injury or blood pooling; the other 1-point or 2-point groups (n = 13, respectively) had no bleeding cases (p = 0.0046). CONCLUSION: Optimization of the surgical field using scope transition and inflow control ensured safe dissection during RDP.


Subject(s)
Pancreatectomy , Pancreatic Neoplasms , Robotic Surgical Procedures , Splenic Artery , Humans , Pancreatectomy/methods , Pancreatectomy/adverse effects , Female , Male , Robotic Surgical Procedures/methods , Middle Aged , Retrospective Studies , Aged , Splenic Artery/surgery , Pancreatic Neoplasms/surgery , Lymph Node Excision/methods , Adult , Treatment Outcome , Ligation , Dissection/methods , Laparoscopy/methods
19.
Gut Liver ; 18(4): 677-685, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38712393

ABSTRACT

Background/Aims: : Appropriate tissue tension and clear visibility of the dissection area using traction are essential for effective and safe endoscopic submucosal dissection (ESD). In this study, we developed a retractable robot-assisted traction device and evaluated its performance in colorectal ESD. Methods: : An experienced endoscopist performed ESD 18 times on an ex vivo porcine colon using the robot and 18 times using the conventional method. The outcome measures were procedure time, dissection speed, procedure-related adverse events, and blind dissection rate. Results: : Thirty-six colonic lesions were resected from ex vivo porcine colon samples. The total procedure time was significantly shorter in robot-assisted ESD (RESD) than in conventional ESD (CESD) (20.1±4.1 minutes vs 34.3±8.3 minutes, p<0.05). The submucosal dissection speed was significantly faster in the RESD group than in the CESD group (36.8±9.2 mm2/min vs 18.1±4.7 mm2/min, p<0.05). The blind dissection rate was also significantly lower in the RESD group (12.8%±3.4% vs 35.1%±3.9%, p<0.05). In an in vivo porcine feasibility study, the robotic device was attached to a colonoscope and successfully inserted into the proximal colon without damaging the colonic wall, and ESD was successfully performed. Conclusions: : The dissection speed and safety profile improved significantly with the retractable RESD. Thus, our robotic device has the potential to provide simple, effective, and safe multidirectional traction during colonic ESD.


Subject(s)
Colon , Endoscopic Mucosal Resection , Operative Time , Robotic Surgical Procedures , Animals , Endoscopic Mucosal Resection/instrumentation , Endoscopic Mucosal Resection/methods , Swine , Robotic Surgical Procedures/instrumentation , Robotic Surgical Procedures/methods , Colon/surgery , Feasibility Studies , Colonoscopy/instrumentation , Colonoscopy/methods , Colorectal Neoplasms/surgery , Dissection/instrumentation , Dissection/methods , Equipment Design
20.
Cir Cir ; 92(2): 242-247, 2024.
Article in English | MEDLINE | ID: mdl-38782378

ABSTRACT

OBJECTIVE: To describe a novel dissector device useful in laparoscopy, better definition of anatomic structures to have a better dissection, separation, and cleaning of the structures. METHOD: The endoscopic dissector DisePad was designed and developed at the experimental surgery department of Centro Médico Nacional 20 de Noviembre, and properly patented at Instituto Mexicano de la Propiedad Industrial (title 3512). RESULTS: The tip of the device is the most important component, by its direct contact with the different tissues, consists of a cotton-polyester black cloth impregnated with a special gel immersed into a hot saline solution. Once soaked the tip maintains the solution temperature on itself. CONCLUSIONS: This device has been used in 364 laparoscopic procedures demonstrating, its utility to visualize, separate and clean anatomical structures without thermal lesion, tear, hemorrhage or visceral perforation.


OBJETIVO: Describir un nuevo dispositivo disector en laparoscopia, con una mejor definición de las estructuras anatómicas para obtener una mejor disección,separación y limpieza de las estructuras. MÉTODO: El disector endoscópico DisePad fue diseñado y desarrollado en el servicio de cirugía experimental del Centro Médico Nacional 20 de Noviembre, y patentado ante el Instituto Mexicano de la Propiedad Industrial (registro n.º 3512). RESULTADOS: El componente más importante del disector es la punta que tiene contacto con los tejidos: es una tela de algodón-poliéster negra impregnada en un gel (patentado) que, al ser sumergido en un termo con solución salina caliente, permite retener la temperatura. CONCLUSIONES: Este dispositivo ha sido utilizado en 364 procedimientos quirúrgicos por vía laparoscópica y ha demostrado ser útil para visualizar, separar y limpiar estructuras anatómicas sin producir daño por lesión térmica, desgarre, hemorragia ni perforación visceral.


Subject(s)
Equipment Design , Laparoscopy , Laparoscopy/instrumentation , Humans , Dissection/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...