Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 9.980
1.
Clin Orthop Surg ; 16(3): 493-505, 2024 Jun.
Article En | MEDLINE | ID: mdl-38827752

Background: Distal metaphyseal-diaphyseal junction fractures of the humerus are a subset of injuries between humeral shaft fractures and distal intra-articular humerus fractures. A lack of space for distal fixation and the unique anatomy of concave curvature create difficulties during operative treatment. The closely lying radial nerve is another major concern. The aim of this study was to determine whether anterolateral dual plate fixation could be effective for a distal junctional fracture of the humerus both biomechanically and clinically. Methods: A right humerus 3-dimensional (3D) model was obtained based on plain radiographs and computed tomography data of patients. Two fractures, a spiral type and a spiral wedge type, were constructed. Three-dimensional models of locking compression plates and screws were constructed using materials provided by the manufacturer. The experiment was conducted by using COMSOL Multiphysics, a finite element analysis, solver, and simulation software package. For the clinical study, from July 2008 to March 2021, a total of 72 patients were included. Their medical records were retrospectively reviewed to obtain patient demographics, elbow range of motion, Disabilities of the Arm, Shoulder and Hand (DASH) scores, Mayo Elbow Performance Scores (MEPS), and hand grip strength. Results: No fracture fixation construct completely restored stiffness comparable to the intact model in torsion or compression. Combinations of the 7-hole and 5-hole plates and the 8-hole and 6-hole plates showed superior structural stiffness and stress than those with single lateral plates. At least 3 screws (6 cortices) should be inserted into the lateral plate to reduce the load effectively. For the anterior plate, it was sufficient to purchase only the near cortex. Regarding clinical results of the surgery, the range of motion showed satisfactory results in elbow flexion, elbow extension, and forearm rotation. The average DASH score was 4.3 and the average MEPS was 88.2. Conclusions: Anterolateral dual plate fixation was biomechanically superior to the single-plate method in the finite element analysis of a distal junctional fracture of the humerus model. Anterolateral dual plate fixation was also clinically effective in a large cohort of patients with distal junctional fractures of the humerus.


Bone Plates , Finite Element Analysis , Fracture Fixation, Internal , Humeral Fractures , Humans , Humeral Fractures/surgery , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Male , Middle Aged , Female , Adult , Retrospective Studies , Biomechanical Phenomena , Aged , Range of Motion, Articular , Humerus/surgery
2.
PLoS One ; 19(6): e0300256, 2024.
Article En | MEDLINE | ID: mdl-38829845

PURPOSE: Due to the increase in life expectancy and high-energy traumas, anterior column acetabular fractures (ACFs) are also increasing. While open reduction and internal fixation (ORIF) is still the standard surgical procedure, minimally invasive, percutaneous fixation of osteoporotic acetabulum fractures (AF) are growing in popularity. The aim of this biomechanical study was to evaluate the biomechanical competence following antegrade fixation with a standard screw versus a cannulated compression headless screw. METHODS: Eight anatomical osteoporotic composite pelvises were given an anterior column fracture. Two groups of eight specimens each (n = 8) for fixation with either a 6.5 mm cannulated compression headless screw in group Anterior Acetabulum Canulated Compression Headless Screw (AACCH), or with a 6.5 mm partially threaded cannulated screw in group Anterior Acetabulum Standard Screw (AASS) where compared. Each specimen was biomechanically loaded cyclically at a rate of 2 Hz with monotonically increasing compressive load until failure. Motions were assessed by means of optical motion tracking. RESULTS: Initial construct stiffness trended higher in group AACCH at 152.4 ± 23.1 N/mm compared to group AASS at 118.5 ± 34.3 N/mm, p = 0.051. Numbers of cycles and corresponding peak load at failure, were significantly higher in group AACCH at 6734 ± 1669 cycles and 873.4 ± 166.9 N versus group AASS at 4440 ± 2063 cycles and 644.0 ± 206.3 N, p = 0.041. Failure modes were breakout of the screws around the proximal entry point. CONCLUSION: From a biomechanical perspective, group AACCH was associated with superior biomechanical competence compared to standard partially threaded cannulated screws and could therefore be considered as valid alternative for fixation of anterior acetabulum fractures.


Acetabulum , Bone Screws , Fracture Fixation, Internal , Acetabulum/surgery , Acetabulum/injuries , Humans , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Biomechanical Phenomena , Fractures, Bone/surgery , Osteoporosis/surgery , Osteoporosis/physiopathology , Osteoporosis/complications
3.
BMC Musculoskelet Disord ; 25(1): 368, 2024 May 10.
Article En | MEDLINE | ID: mdl-38730497

BACKGROUND: This systemic review and meta-analysis aimed to evaluate the clinical outcomes of proximal humeral fracture in elderly patient fixation using locked plate with or without cement augmentation. METHODS: The databases of PubMed, Embase, and Cochrane Library were searched in August 2023 for literature comparing the clinical outcomes of patients with PHFs treated with locked plate alone and locked plate augmented with cement. Data describing study design; level of evidence; inclusion criteria; demographic information; final follow-up; revision rate; implant failure rate; avascular necrosis rate; total complication rate; constant score; and disability of arm, shoulder, and hand (DASH) score were collected. RESULTS: Eight studies (one randomized-controlled trial and seven observational studies), involving 664 patients, were identified. Compared with locked plates alone, using cement-augmented locked plates reduced the implant failure rate (odds ratio (OR) = 0.19; 95% confidence interval (CI) 0.10-0.39; P < 0.0001) and total complication rate (OR = 0.45; 95% CI 0.29-0.69; P = 0.0002) and improved DASH scores (mean difference (MD) = 2.99; 95% CI 1.00-4.98; P = 0.003). However, there was no significant difference in clinical outcomes, including revision rate, avascular necrosis rate, and constant score. CONCLUSION: In this review and meta-analysis, fixation of the PHFs in elderly patients using locked plates with or without cement augmentation has no significant difference in revision rate, but the implant failure and total complication rates may be lesser on using the cement-augmented locked plate for fixation than on using a locked plate alone. Good results are expected for most patients treated with this technique. TRIAL REGISTRATION: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA)21 guidelines were followed to conduct this systematic review and meta-analysis and was registered as a protocol in PROSPERO (CRD42022318798).


Bone Cements , Bone Plates , Fracture Fixation, Internal , Shoulder Fractures , Humans , Shoulder Fractures/surgery , Shoulder Fractures/diagnostic imaging , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/adverse effects , Bone Cements/therapeutic use , Bone Cements/adverse effects , Aged , Treatment Outcome , Aged, 80 and over , Postoperative Complications/etiology , Postoperative Complications/epidemiology , Reoperation
4.
BMC Musculoskelet Disord ; 25(1): 350, 2024 May 03.
Article En | MEDLINE | ID: mdl-38702748

BACKGROUND: Metacarpal shaft fracture is a common type of hand fracture. Numerous studies have explored fixing transverse fractures in the midshaft of the metacarpal bone. However, this section of the metacarpal bone is often susceptible to high-energy injury, resulting in comminuted fracture or bone loss. In such cases, wedge-shaped bone defects can develop in the metacarpal shaft, increasing the difficulty of performing fracture fixation. Notably, the research on this type of fracture fixation is limited. This study compared the abilities of four fixation methods to fix metacarpal shaft fractures with wedge-shaped bone defects. METHODS: In total, 28 artificial metacarpal bones were used. To create wedge-shaped bone defects, an electric saw was used to create metacarpal shaft fractures at the midshaft of each bone. The artificial metacarpal bones were then divided into four groups for fixation. The bones in the first group were fixed with a dorsal locked plate (DP group), those in the second group were fixed with a volar locked plate (VP group), and those in the third group were fixed by combining dorsal and volar locked plates (DP + VP group), and those in the fourth group were fixed with two K-wires (2 K group). Cantilever bending tests were conducted using a material testing machine to measure yielding force and stiffness. The four groups' fixation capabilities were then assessed through analysis of variance and Tukey's test. RESULTS: The DP + VP group (164.1±44.0 N) achieved a significantly higher yielding force relative to the 2 K group (50.7 ± 8.9 N); the DP group (13.6 ± 3.0 N) and VP group (12.3 ± 1.0 N) did not differ significantly in terms of yielding force, with both achieving lower yielding forces relative to the DP + VP group and 2 K group. The DP + VP group (19.8±6.3 N/mm) achieved the highest level of stiffness, and the other three groups did not differ significantly in terms of stiffness (2 K group, 5.4 ± 1.1 N/mm; DP group, 4.0 ± 0.9 N/mm; VP group, 3.9 ± 1.9 N/mm). CONCLUSIONS: The fixation method involving the combined use of dorsal and volar locked plates (DP + VP group) resulted in optimal outcomes with respect to fixing metacarpal shaft fractures with volar wedge bone defects.


Bone Plates , Bone Wires , Fracture Fixation, Internal , Fractures, Bone , Metacarpal Bones , Metacarpal Bones/injuries , Metacarpal Bones/surgery , Humans , Biomechanical Phenomena , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Fractures, Bone/surgery
5.
Jt Dis Relat Surg ; 35(2): 439-442, 2024 Apr 26.
Article En | MEDLINE | ID: mdl-38727126

Tension band wiring (TBW) is one of the most commonly used fixation techniques to fix olecranon osteotomies. Hardware prominence has been the most commonly reported complication of TBW. However, distal migration of Kirschner (K)-wire after TBW fixation for olecranon osteotomy has not been reported. In this case report, we presented distal migration of K-wire detected nine months after initial surgery in a 46-year-old male patient. The patient was operated on for an intraarticular distal humerus fracture using an olecranon osteotomy. The osteotomy was fixed with TBW fixation. The patient missed routine follow-ups and presented to the outpatient clinic with a complaint of skin irritation at the elbow nine months after the surgery. On radiological examination, distal migration of one K-wire was detected. The K-wire was surgically removed without any complication. Physicians should be aware of possible complications of TBW and remove fixation after fracture union to avoid unexpected complications.


Bone Wires , Foreign-Body Migration , Olecranon Process , Osteotomy , Humans , Bone Wires/adverse effects , Male , Middle Aged , Olecranon Process/injuries , Olecranon Process/surgery , Olecranon Process/diagnostic imaging , Osteotomy/adverse effects , Osteotomy/methods , Osteotomy/instrumentation , Foreign-Body Migration/surgery , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/etiology , Humeral Fractures/surgery , Humeral Fractures/diagnostic imaging , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Device Removal/methods , Elbow Joint/surgery , Elbow Joint/diagnostic imaging , Intra-Articular Fractures/surgery , Intra-Articular Fractures/diagnostic imaging
6.
BMC Musculoskelet Disord ; 25(1): 343, 2024 May 01.
Article En | MEDLINE | ID: mdl-38693479

PURPOSE: To explore whether it is necessary to put drain tubes after posterior pedicle screw fixation of thoracolumbar fractures. METHODS: From April 2020 to January 2023, a total of 291 patients with recent thoracolumbar fractures (AO type-A or type-B) who received the pedicle screw fixation operation were enrolled retrospectively. In 77 patients, drain tubes were used in the pedicle screw fixation surgery, while no drain tubes were placed in the other group. After gleaning demographic information and results of lab examination and imageology examination, all data were put into a database. Independent-sample t-tests, Pearson Chi-Square tests, Linear regression analysis, and correlation analysis were then performed. RESULTS: Compared to the control group, the drainage group had significantly lower postoperative CRP levels (P = 0.047), less use of antipyretics (P = 0.035), higher ADL scores (P = 0.001), and lower NRS scores (P < 0.001) on the 6th day after surgery. Other investigation items, such as demographic information, operation time, intraoperative blood loss, body temperature, and other preoperative and postoperative lab results, showed no significant differences. CONCLUSIONS: The use of a drain tube in the pedicle screw fixation of thoracolumbar fractures is correlated with the improvement of patients' living and activity ability and the reduction of inflammation, postoperative fever and pain.


Drainage , Fracture Fixation, Internal , Lumbar Vertebrae , Pedicle Screws , Spinal Fractures , Thoracic Vertebrae , Humans , Male , Thoracic Vertebrae/surgery , Thoracic Vertebrae/injuries , Spinal Fractures/surgery , Spinal Fractures/diagnostic imaging , Lumbar Vertebrae/surgery , Lumbar Vertebrae/injuries , Female , Retrospective Studies , Adult , Middle Aged , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/adverse effects , Drainage/instrumentation , Drainage/methods , Treatment Outcome , Aged
7.
PLoS One ; 19(5): e0302839, 2024.
Article En | MEDLINE | ID: mdl-38696506

PURPOSES: Fractures of the inferior patellar pole, unlike other patellar fractures, present challenges for traditional surgical fixation methods. This article introduces the clinical technique and outcomes of using Kirschner wire tension band combined with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures. METHODS: This retrospective case series study included 14 patients with comminuted inferior patellar pole fractures treated at our institution from September 1, 2020, to April 30, 2022. All patients underwent surgery using the Kirschner wire tension band with anchor screw cross-stitch technique. Follow-up assessments involved postoperative X-rays to evaluate fracture healing, as well as clinical parameters such as healing time, Visual Analog Scale (VAS) scores, range of motion (ROM), and Bostman scores. RESULTS: All patients were followed for an average of over 12 months, with no cases of internal fixation failure. Knee joint stability and function were excellent. X-rays revealed an average healing time of approximately 10.79 ± 1.53 weeks, hospitalization lasted 5.64 ± 1.15 days, surgery took approximately 37.86 ± 5.32 minutes, and intraoperative blood loss was 33.29 ± 8.15 ml. One patient experienced irritation from the internal fixation material. At the final follow-up, the Bostman score averaged 28.29 ± 0.83, knee joint flexion reached 131.07° ± 4.88°, all patients achieved full knee extension, and the VAS score was 0.36 ± 0.63. CONCLUSION: Kirschner wire tension band with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures delivered satisfactory clinical outcomes. This surgical method, characterized by its simplicity and reliability, is a valuable addition to clinical practice.


Bone Wires , Fracture Fixation, Internal , Fractures, Comminuted , Patella , Humans , Male , Female , Adult , Patella/surgery , Patella/injuries , Fractures, Comminuted/surgery , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Retrospective Studies , Middle Aged , Range of Motion, Articular , Treatment Outcome , Fractures, Bone/surgery , Fracture Healing , Knee Joint/surgery , Knee Joint/physiopathology , Young Adult , Bone Screws , Suture Anchors
8.
Dan Med J ; 71(5)2024 Apr 10.
Article En | MEDLINE | ID: mdl-38704836

INTRODUCTION: Following surgical management of patella fractures, patients commonly report pain; difficulties with weight-bearing tasks such as walking, running and climbing stairs; and restrictions in quality of life. Recently, a locking plate system for surgical management of patella fractures has been introduced. To date, no studies have compared standard treatment with tension band wiring with locking plate fixation in a randomised study design. We aim to compare the one-year patient-reported Knee Injury and Osteoarthritis Outcome subscale scores (KOOS5-subscales) after standard care tension band fixation with locking plate fixation for patients with patella fractures. METHODS: This is a multicentre randomised and prospective clinical trial. A total of 122 patients will be included in the study, and the primary outcome will be the KOOS subscales at 12 months after surgery. CONCLUSIONS: Findings from the present study are expected to advance our understanding of outcome following surgical treatment of patella fractures. FUNDING: This study is funded, in part, by the Novo Nordisk Foundation, Denmark. CLINICALTRIALS: gov ID: NCT04891549.


Bone Plates , Fracture Fixation, Internal , Fractures, Bone , Patella , Humans , Patella/injuries , Patella/surgery , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Fractures, Bone/surgery , Prospective Studies , Female , Male , Treatment Outcome , Bone Wires , Adult , Randomized Controlled Trials as Topic , Middle Aged , Denmark , Quality of Life , Patella Fracture
9.
Eur Rev Med Pharmacol Sci ; 28(8): 3208-3215, 2024 Apr.
Article En | MEDLINE | ID: mdl-38708479

OBJECTIVE: We sought to explore the effectiveness of cannulated screw fixation for femoral neck fractures in middle-aged and elderly patients assisted by a three-dimensional printing navigation template. PATIENTS AND METHODS: A total of 98 middle-aged and elderly patients who underwent cannulated screw fixation for femoral neck fractures were retrospectively analyzed. They were allocated into two groups, each comprising 49 patients. Surgical indexes, hip function, and pain levels were compared between the two groups. RESULTS: The study group, assisted by the three-dimensional printing navigation template, exhibited significantly reduced nail insertion, fewer instances of C-arm fluoroscopy, shorter operation time, quicker time to bone union, earlier initiation of walking exercise, shorter time to weight-bearing walking, and reduced hospital stay than those in the control group (all p<0.001). However, the study group also experienced higher blood loss compared to the control group (p<0.001). Postoperatively, at 3 months and 12 months, the study group demonstrated significantly higher scores compared to the control group (both p<0.001) and reported significantly lower pain scores than that in the other group at 1 week and 12 months post-surgery (both p<0.001). Furthermore, the study group experienced significantly fewer postoperative complications than the control group (p=0.029). CONCLUSIONS: Cannulated screw fixation for femoral neck fractures assisted by a 3D printing navigation template is more effective and safer than traditional fixation methods. This approach represents a promising alternative for surgical management.


Bone Screws , Femoral Neck Fractures , Fracture Fixation, Internal , Printing, Three-Dimensional , Humans , Femoral Neck Fractures/surgery , Middle Aged , Aged , Female , Male , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Retrospective Studies
10.
J Plast Surg Hand Surg ; 59: 46-52, 2024 May 15.
Article En | MEDLINE | ID: mdl-38747532

Standard volar plates often do not fit the surface of the malunited distal radius after osteotomy, necessitating an offset angle for accurate volar tilt correction. The correction can be achieved if the plate is held at the correct angle when the distal screws are locked. With the advantage of 3D surgical planning and patient-specific instruments, we developed a shim instrument to assist the surgeon in securing the plate at the intended angle when locking the distal screws, and evaluated radiological results. Five female patients aged 63-74 with dorsally angulated extra-articular malunions underwent surgery using 3D-printed guides and the shim instrument. The plate position, drilling guide alignment, screw placements, and distal radius correction on postoperative CTs were compared with the surgical plans. Errors were measured using an anatomical coordinate system, and standard 2D radiographic measures were extracted. Preoperative dorsal tilt ranged from 16° to 35°, and postoperative volar tilt from 1° to 11°. 3D analysis revealed mean absolute correction errors of 6.1° in volar tilt, 1.6° in radial inclination, and 0.6 mm in ulnar variance. The volar tilt error due to the shim instrument, indicated by the mean angle error of the distal screws to the plate, was 2.1° but varied across the five patients. Settling of the distal radius, due to tension during and after reduction, further contributed to a mean loss of 3.5° in volar tilt. The shim instrument helped with securing plates at the intended angle; however, further correction improvements should consider the tension between the fragments of osteoporotic bone.


Bone Plates , Fracture Fixation, Internal , Fractures, Malunited , Osteotomy , Radius Fractures , Humans , Female , Osteotomy/methods , Osteotomy/instrumentation , Middle Aged , Radius Fractures/surgery , Radius Fractures/diagnostic imaging , Aged , Fractures, Malunited/surgery , Fractures, Malunited/diagnostic imaging , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Printing, Three-Dimensional , Surgery, Computer-Assisted , Imaging, Three-Dimensional , Bone Screws , Tomography, X-Ray Computed
11.
Medicine (Baltimore) ; 103(20): e38252, 2024 May 17.
Article En | MEDLINE | ID: mdl-38758854

The management of comminuted quadrilateral fractures remains challenging, and treatment options are constantly evolving. The purpose of the present study was to examine the outcomes of 2 different fixation techniques in the management of comminuted quadrilateral fractures. Twenty-two patients with comminuted quadrilateral acetabular fractures were surgically treated with interfragmentary lag screw (group 1) and square bracket-shaped tubular (SBST) plate technique (group 2), in addition to suprapectineal and infrapectineal pelvic reconstruction plate fixation between January 2016 and July 2019 at our clinic. 2 years follow-up control data of each group were compared in terms of radiological and functional results, and complications. According to the functional score comparison, the mean Merle d'Aubigne Postel scoring system (MAP) score was 15.2/15.6 (P = .632), and the mean Harris hip scoring (HHS) system score was 74.65/77.3 (P = .664) in groups 1 and 2, respectively. Radiological comparison was performed according to matta radiological criteria (MRC), and 2 excellent, 6 good, 2 poor, 4 excellent, 4 good, and 4 poor radiological results were observed in groups 1 and 2, respectively. intraarticular screw penetration was detected in 3 patients in group 1, while there was no articular implant penetration in group 2 (P = .001). We believe that satisfactory results can be obtained with the SBST plate technique, offering functional and clinical outcomes that are similar to those of the interfragmentary screw technique. The SBST plate technique is superior in terms of avoiding intraarticular screw penetration and related revision surgery.


Acetabulum , Bone Plates , Bone Screws , Fracture Fixation, Internal , Fractures, Comminuted , Humans , Acetabulum/surgery , Acetabulum/injuries , Acetabulum/diagnostic imaging , Female , Male , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Middle Aged , Adult , Fractures, Comminuted/surgery , Fractures, Comminuted/diagnostic imaging , Treatment Outcome , Retrospective Studies , Fractures, Bone/surgery , Fractures, Bone/diagnostic imaging
12.
Medicine (Baltimore) ; 103(20): e38258, 2024 May 17.
Article En | MEDLINE | ID: mdl-38758846

BACKGROUND: The aim of this study was to compare the biomechanical performance of pedicle screw construction and locking compression plate fixation in posterior pelvic ring injuries analyzed by finite element method. METHODS: A 3-dimensional finite element model of the spine-pelvis-femur complex with ligaments was reconstructed from computed tomography images. An unstable posterior pelvic ring injury was created, which was fixed with a pedicle screw construction or locking compression plate. A follower load of 400 N was applied to the upper surface of the vertebrae to simulate the upper body weight, while the ends of the proximal femurs were fixed. The construct stiffness, the maximum vertical displacement, the maximum posterior displacement, the maximum right displacement, and the overall maximum displacement of the sacrum, and stress distributions of the implants and pelvises were assessed. RESULTS: The construct stiffness of the pedicle screw model (435.14 N/mm) was 2 times that of the plate model (217.01 N/mm). The maximum vertical displacement, the maximum posterior displacement, the maximum right displacement, and the overall maximum displacement of the sacrum in the pedicle screw model were smaller than those in the plate model (0.919, 1.299, 0.259, and 1.413 mm in the pedicle screw model, and 1.843, 2.300, 1.053, and 2.895 mm in the plate model, respectively). The peak stresses of the implant and pelvis in the pedicle screw model decreased by 80.4% and 25% when compared with the plate model (44.57 and 34.48 MPa in the pedicle screw model, and 227.47 and 45.97 MPa in the plate model, respectively). CONCLUSION: The study suggested that the pedicle screw construction could provide better fixation stability than the locking compression plate and serves as the recommended fixation method for the treatment of posterior pelvic ring injuries.


Bone Plates , Finite Element Analysis , Fracture Fixation, Internal , Pedicle Screws , Pelvic Bones , Humans , Pelvic Bones/injuries , Pelvic Bones/surgery , Biomechanical Phenomena , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Tomography, X-Ray Computed , Fractures, Bone/surgery
13.
PLoS One ; 19(5): e0296149, 2024.
Article En | MEDLINE | ID: mdl-38748687

BACKGROUND: The recommendation on whether to bury or expose the Kirschner wire (K-wire) for the management of fractures has still been controversial with inconsistent results in the published studies due to the potential issue associated with exposed K-wire is the heightened risk of infection, as it comes into direct contact with the external environment and air. This study aims to summarize the specific outcomes between buried and exposed K-wire for the management of hand and forearm fractures. METHODS: We conducted relevant literature searches on Europe PMC, Medline, Scopus, and Cochrane Library databases using specific keywords. This investigation focuses on individuals of any age diagnosed with hand or forearm fractures who underwent surgery involving Kirschner wire (K-wire) fixation. It examines the comparison between buried and exposed K-wire fixation, emphasizing primary outcome pin infection, along with secondary outcomes such as early pin removal, days to pin removal, and surgical duration. The study includes observational studies (cohort/case-control) or randomized clinical trials (RCTs). The results of continuous variables were pooled into the standardized mean difference (SMD), while dichotomous variables were pooled into odds ratio (OR) along with 95% confidence intervals using random-effect models. The quality of included studies was assessed with Cochrane Collaborations, Risk of Bias version 2 (RoB v2). RESULTS: A total of 11 studies were included. Our pooled analysis revealed that buried K-wire was associated with a lower risk of pin site infection [RR 0.49 (95% CI 0.36-0.67), p < 0.00001, I2 = 0%] and 33.85 days longer duration until pin removal [MD 33.85 days (95% CI 18.68-49.02), p < 0.0001, I2 = 99%] when compared with exposed K-wire. However, the duration of surgery was 9.98 minutes significantly longer in the buried K-wire [MD 6.98 minutes (95% CI 2.19-11.76), p = 0.004, I2 = 42%] with no significant difference in the early pin removal rate [RR 0.73 (95% CI 0.36-1.45), p = 0.37, I2 = 0%]. Further regression analysis revealed that sample size, age, sex, and duration of follow-up did not affect those relationships. CONCLUSION: Buried K-wire may offer benefits in reducing the infection rate with a longer duration until pin removal. However, further RCTs with larger sample sizes are still needed to confirm the results of our study.


Bone Wires , Humans , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/adverse effects , Fractures, Bone/surgery , Hand Bones/surgery , Hand Bones/injuries , Forearm Injuries/surgery
14.
Medicina (Kaunas) ; 60(5)2024 Apr 23.
Article En | MEDLINE | ID: mdl-38792863

Introduction: Basicervical femoral neck fracture (FNF) is an uncommon type of femoral neck fracture and is associated with an increased risk of fixation failure due to its inherent instability. The purpose of this study was to compare the surgical parameters and reoperation rate between the use of a multiple cannulated screw (MCS) and fixed angle device (FAD) in treating basicervical FNFs. Methods: We retrospectively reviewed the records of 885 patients who underwent internal fixation between May 2004 and August 2019 to determine basicervical FNF with at least 12 months of follow-up. Among the identified 77 patients with basicervical FNF, 17 patients who underwent multiple cannulated screw (MCS) fixation and 36 patients who underwent fixed angle device (FAD) fixation were included. We compared the rates of fracture-site collapse and reoperations according to the fixation device. Results: Among the 53 patients with basicervical FNF, 13 patients (24.5%) sustained surgical complications (8 collapses of fracture site and 5 reoperations). The reoperation rate in the MCS group was significantly higher than that in the FAD group (23.5% vs. 2.8%, p = 0.016), without any significant difference in the collapse of the fracture site (11.8% vs. 16.7%, p = 0.642). Conclusions: Although basicervical FNF was rare among hip fractures, fracture site collapse was prevalent and prone to fixation failure. Surgeons should keep this in mind, and consider FAD for basicervical FNF.


Bone Screws , Femoral Neck Fractures , Fracture Fixation, Internal , Humans , Femoral Neck Fractures/surgery , Female , Male , Retrospective Studies , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/statistics & numerical data , Aged , Middle Aged , Treatment Outcome , Reoperation/statistics & numerical data , Aged, 80 and over , Postoperative Complications/epidemiology
15.
Sci Rep ; 14(1): 12569, 2024 05 31.
Article En | MEDLINE | ID: mdl-38822126

We have developed a novel osteosynthesis plate with bone union detection using a wire's natural frequency (BUDWF) to provide the quantitative result of bone union detection. The concept for detecting bone union is measuring the rate of frequency change. The frequency is measured from sound generated from the wire attached to a modified plate. The plate is modified from a Syncera ADLER B0409.10 and attached with 0.3 mm diameter 316L stainless steel wire. The sound generation mechanism was created by PEEK and installed on the plate to generate the sound. The preliminary experiments were conducted on a Sawbones tibia composite mimic. We used the cut Sawbones to create fracture samples with a 0, 0.5, 1-, 2-, and 5-mm gap representing the fractured bone with different gap sizes and prepared uncut Sawbones as a union sample. These samples were tested five times, and the sound was recorded from a condenser microphone and analyzed. We found that the BUDWF can differentiate samples with a fracture gap above 2 mm from the union sample, as the differences in the rates of frequency change between samples with a fracture gap above 2 mm and union samples were statistically significant. However, there was a limitation that the BUDWF plate was still unable to differentiate the 0 mm fracture gap and the union sample in this study.


Bone Plates , Fracture Fixation, Internal , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Humans , Bone Wires , Fracture Healing
16.
Trials ; 25(1): 305, 2024 May 06.
Article En | MEDLINE | ID: mdl-38711052

BACKGROUND: To analyze the perioperative bleeding and hidden blood loss (HBL) of sacroiliac screw minimally invasive treatment of pelvic posterior ring injury and explore the influential factors of HBL after operation for providing reference for clinical treatment. METHOD: A retrospective analysis was conducted on data from 369 patients with posterior pelvic ring injuries treated with sacroiliac screws internal fixation at our hospital from January 2015 to January 2022. The research was registered in the Chinese Clinical Trial Registry in July 2022 (ChiCTR2200061866). The total blood loss (TBL) and HBL of patients were counted, and the factors such as gender, age, and surgical duration were statistically analyzed. The influential factors of HBL were analyzed by multiple linear regression. RESULTS: The TBL was 417.96 ± 98.05 ml, of which the visible blood loss (VBL) was 37.00 ± 9.0 ml and the HBL was 380.96 ± 68.8 ml. The HBL accounted for 91.14 ± 7.36% of the TBL. Gender, surgical duration, fixed position, and fixed depth had significant effects on the HBL (P < 0.05). CONCLUSIONS: The HBL was the main cause of anemia after minimally invasive treatment of posterior pelvic ring injury with a sacroiliac screw. Gender, surgical duration, fixed position, and fixed depth were closely related to the occurrence of HBL. In clinical treatment, we should consider these influential factors and take effective measures to reduce the impact of HBL on patients.


Blood Loss, Surgical , Bone Screws , Fracture Fixation, Internal , Pelvic Bones , Humans , Male , Female , Retrospective Studies , Pelvic Bones/injuries , Pelvic Bones/surgery , Adult , Middle Aged , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Treatment Outcome , Risk Factors , Young Adult , Fractures, Bone/surgery , Fractures, Bone/diagnostic imaging , Time Factors , China , Aged , Minimally Invasive Surgical Procedures/methods , Anemia/etiology
17.
Cir Cir ; 92(2): 211-218, 2024.
Article En | MEDLINE | ID: mdl-38782385

OBJECTIVES: The aim of the study was to investigate the clinical effect of stainless-steel wire fixation on the early mouth-opening movement of an intracapsular fracture involving the condylar process. MATERIALS AND METHODS: In this study, patients who underwent mandibular condylar intracapsular fracture surgery in our hospital from 2012 to 2020 were selected as research subjects. A total of 44 patients received steel wire internal fixation treatment, 32 patients received titanium plate-and-nail rigid internal fixation, and 28 patients underwent conservative non-surgical treatment. RESULTS: For the patients in the stainless-steel wire group, the degree of mouth opening reached normal levels of 3.7 cm approximately 10 days after surgery. The recovery time for the patients in the titanium plate-and-nail rigid internal-fixation group was 21 days, while the patients in the conservative treatment group needed 60 days to recover. CONCLUSION: The treatment of fixation with a stainless-steel wire for intracapsular condylar fracture reduced the time taken to perform mouth-opening exercises and improved the recovery rate of patients.


OBJETIVO: Explorar el efecto clínico de la fijación de alambre de acero inoxidable en el movimiento temprano de apertura de la boca en la fractura interna del cóndilo. MÉTODO: Este estudio seleccionó a pacientes que se sometieron a cirugía de fractura intracapsular de cóndilo en nuestro hospital de 2012 a 2020 como sujetos de investigación. Un total de 44 pacientes recibieron tratamiento de fijación interna de alambre de acero, 32 recibieron placa de titanio y fijación interna con clavos, y 28 recibieron tratamiento conservador no quirúrgico. RESULTADOS: En los pacientes del grupo de alambre de acero inoxidable, alrededor de 10 días después de la cirugía el grado de apertura de la boca alcanzó un valor normal de 3.7 cm. El tiempo de recuperación de los pacientes en el grupo de fijación interna con clavos y placa de titanio fue de 21 días, mientras que los pacientes en el grupo de tratamiento conservador tardaron 60 días en recuperarse. CONCLUSIONES: La fijación con alambre de acero inoxidable para el tratamiento de la fractura intracapsular del cóndilo acorta el tiempo hasta la apertura de la boca y mejora la tasa de recuperación de los pacientes.


Bone Plates , Bone Wires , Fracture Fixation, Internal , Mandibular Condyle , Mandibular Fractures , Stainless Steel , Humans , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Mandibular Fractures/surgery , Mandibular Condyle/injuries , Mandibular Condyle/surgery , Male , Female , Adult , Middle Aged , Titanium , Range of Motion, Articular , Bone Nails , Young Adult , Retrospective Studies
18.
Cir Cir ; 92(2): 141-149, 2024.
Article En | MEDLINE | ID: mdl-38782391

BACKGROUND: Clavicle fractures represent 2.5-4% of all fractures observed in emergency services. 80% occurs in the middle third. Treatment by plating requires a higher level of evidence. OBJECTIVE: To compare the functional outcomes of mid-shaft clavicle fractures managed with superior plating compared to anteroinferior plating. TRIAL DESIGN: A randomized, double-blind, parallel, superiority clinical trial. PATIENTS AND METHODS: Patients with fractures of the clavicles AO15B1 and AO15B2 were studied. Patients were randomized to be treated with either 3.5 mm superior or anteroinferior plating. A rehabilitation program was designed for both groups. The primary outcome measure was the Disability of Arm, Shoulder, and Hand (DASH) score; secondary outcomes included pain, union rate, and complication rates. RESULTS: Twenty-eight patients were studied and were eligible for analysis. Significant differences were found in the function assessed with the DASH score at 30 days for the superior plating compared with anteroinferior (43.74 vs. 29.26, respectively, p = 0.027), 60 days (23.97 vs. 11.18, p = 0.021), and 90 days (9.52 vs. 3.5, p = 0.016). One loosening with superficial infection was found with superior plating. CONCLUSIONS: Using an anteroinferior reconstruction plate in diaphyseal fractures offers better functional results than the upper plate in patients with fractures of the middle third of the clavicle.


ANTECEDENTES: Las fracturas de clavícula comprenden el 2.5-4% de todas las fracturas observadas en los servicios de emergencia. El 80% se presentan en el tercio medio. La posición de la placa como tratamiento requiere mayor nivel de evidencia. OBJETIVO: Comparar los resultados funcionales de las fracturas diafisarias de clavícula manejadas con placa superior versus placa anteroinferior. MÉTODO: Ensayo clínico aleatorizado, doble ciego, paralelo, de superioridad. Se estudiaron pacientes con fractura diafisaria de clavícula AO15B1 y AO15B2. Se manejaron con placa de reconstrucción de 3.5 mm colocada en forma superior o anteroinferior. Se diseñó un programa de rehabilitación para ambos grupos. El resultado primario fue medido con el cuestionario DASH y los resultados secundarios incluyeron dolor, presencia de consolidación y complicaciones. RESULTADOS: Fueron elegibles para análisis 28 pacientes. Se encontraron diferencias significativas de la escala DASH a los 30 días para la maniobra superior comparada con la inferior (43.74 vs. 29.26, respectivamente; p = 0.027), a los 60 días (23.97 vs. 11.18; p = 0.021) y a los 90 días (9.52 vs. 3.5; p = 0.016). CONCLUSIONES: El uso de placa de reconstrucción anteroinferior en las fracturas diafisarias ofrece mejores resultados funcionales en comparación con la placa superior en pacientes con fracturas de tercio medio de clavícula.


Bone Plates , Clavicle , Fracture Fixation, Internal , Fractures, Bone , Humans , Clavicle/injuries , Clavicle/surgery , Male , Female , Fractures, Bone/surgery , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Adult , Double-Blind Method , Middle Aged , Treatment Outcome , Postoperative Complications/etiology , Postoperative Complications/epidemiology , Young Adult
19.
BMC Surg ; 24(1): 157, 2024 May 16.
Article En | MEDLINE | ID: mdl-38755649

BACKGROUND: Fractures involving the posterior acetabulum with its rich vascular and neural supply present challenges in trauma orthopedics. This study evaluates the effectiveness of 3D printing technology with the use of custom-made metal plates in the treatment of posterior wall and column acetabular fractures. METHODS: A retrospective analysis included 31 patients undergoing surgical fixation for posterior wall and column fractures of the acetabulum (16 in the 3D printing group, utilizing 3D printing for a 1:1 pelvic model and custom-made plates based on preoperative simulation; 15 in the traditional group, using conventional methods). Surgical and instrument operation times, intraoperative fluoroscopy frequency, intraoperative blood loss, fracture reduction quality, fracture healing time, preoperative and 12-month postoperative pain scores (Numeric Rating Scale, NRS), hip joint function at 6 and 12 months (Harris scores), and complications were compared. RESULTS: The surgical and instrument operation times were significantly shorter in the 3D printing group (p < 0.001). The 3D printing group exhibited significantly lower intraoperative fluoroscopy frequency and blood loss (p = 0.001 and p < 0.001, respectively). No significant differences were observed between the two groups in terms of fracture reduction quality, fracture healing time, preoperative pain scores (NRS scores), and 6-month hip joint function (Harris scores) (p > 0.05). However, at 12 months, hip joint function and pain scores were significantly better in the 3D printing group (p < 0.05). Although the incidence of complications was lower in the 3D printing group (18.8% vs. 33.3%), the difference did not reach statistical significance (p = 0.433). CONCLUSION: Combining 3D printing with individualized custom-made metal plates for acetabular posterior wall and column fractures reduces surgery and instrument time, minimizes intraoperative procedures and blood loss, enhancing long-term hip joint function recovery. CLINICAL TRIAL REGISTRATION: 12/04/2023;Trial Registration No. ChiCTR2300070438; http://www.chictr.org.cn .


Acetabulum , Bone Plates , Fracture Fixation, Internal , Fractures, Bone , Printing, Three-Dimensional , Humans , Retrospective Studies , Acetabulum/surgery , Acetabulum/injuries , Male , Female , Adult , Middle Aged , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Treatment Outcome , Fractures, Bone/surgery , Operative Time , Young Adult , Prosthesis Design , Aged
20.
Zhongguo Gu Shang ; 37(5): 458-63, 2024 May 25.
Article Zh | MEDLINE | ID: mdl-38778528

OBJECTIVE: To analyze and compare the clinical effects of femoral neck dynamic cross screw system (FNS) and cannulated screws(CS) in the treatment of vertically unstable femoral neck fractures. METHODS: The clinical data and short-term follow-up results of 40 patients with vertically unstable femoral neck fractures admitted from July 2020 to August 2021 were retrospectively analyzed. According to different internal fixation methods, 40 patients were divided into two groups, 20 cases in FNS group included 11 males and 9 females with a median of 58.5(50.3, 62.5) years old, and 20 in CS group included 9 males and 11 females with a median of 52.0(40.5, 58.0) years old. The operation time, knife edge length, blood loss and treatment cost of two gruops were observed and compared. The postoperative fracture healing and internal fixation were evaluated with X-ray imaging data, and the femoral neck shortening of the affected side was measured. The incidence of thigh irritation, the time of partial weight bearing and full weight bearing, early necrosis of femoral head, reoperation revision and Harris scores were compared between two groups. RESULTS: FNS group was followed up for 18.0(15.0, 19.0) months, CS group for 17.0(15.0, 18.8) months. There was no significant difference in operation time, incision length and blood loss between two groups(P>0.05). The cost of diagnosis and treatment in FNS group was higher than that in CS group(P<0.001). In FNS group, there was no irritation sign of the affected side thigh, while in CS group, there were 6 cases with discomfort or irritation sign of the lateral thigh(P<0.05). The average time of partial weight bearing activity in CS group was later than that in FNS group(P<0.05); However, there was no significant difference in the activity time of complete weight bearing between two groups(P=0.011>0.05). At the last follow-up, the shortened length of the affected femoral neck in CS group was greater than that in FNS group(P<0.05). There was no early necrosis of femoral head and reoperation in both groups. There was no significant difference in Harris score between two groups 12 months after operation(P>0.05). CONCLUSION: FNS treatment of vertically unstable femoral neck fractures can significantly reduce the incidence of lateral thigh irritation sign, and effectively reduce the postoperative shortening rate of vertically unstable femoral neck fractures, which can provide a relatively stable anti rotation force and anti cutting force, so that patients can go to the ground relatively early, which is conducive to the recovery of the affected hip joint function after surgery. It is a new option for the surgical treatment of vertically unstable femoral neck fractures. However, due to the high cost of treatment, In clinical practice, appropriate surgical treatment is selected according to the actual situation.


Bone Screws , Femoral Neck Fractures , Fracture Fixation, Internal , Humans , Femoral Neck Fractures/surgery , Male , Female , Middle Aged , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Follow-Up Studies , Retrospective Studies , Adult
...