Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 25.539
2.
J Biomed Opt ; 29(Suppl 3): S33302, 2024 Jun.
Article En | MEDLINE | ID: mdl-38707651

Significance: Cerebral oximeters have the potential to detect abnormal cerebral blood oxygenation to allow for early intervention. However, current commercial systems have two major limitations: (1) spatial coverage of only the frontal region, assuming that surgery-related hemodynamic effects are global and (2) susceptibility to extracerebral signal contamination inherent to continuous-wave near-infrared spectroscopy (NIRS). Aim: This work aimed to assess the feasibility of a high-density, time-resolved (tr) NIRS device (Kernel Flow) to monitor regional oxygenation changes across the cerebral cortex during surgery. Approach: The Flow system was assessed using two protocols. First, digital carotid compression was applied to healthy volunteers to cause a rapid oxygenation decrease across the ipsilateral hemisphere without affecting the contralateral side. Next, the system was used on patients undergoing shoulder surgery to provide continuous monitoring of cerebral oxygenation. In both protocols, the improved depth sensitivity of trNIRS was investigated by applying moment analysis. A dynamic wavelet filtering approach was also developed to remove observed temperature-induced signal drifts. Results: In the first protocol (28±5 years; five females, five males), hair significantly impacted regional sensitivity; however, the enhanced depth sensitivity of trNIRS was able to separate brain and scalp responses in the frontal region. Regional sensitivity was improved in the clinical study given the age-related reduction in hair density of the patients (65±15 years; 14 females, 13 males). In five patients who received phenylephrine to treat hypotension, different scalp and brain oxygenation responses were apparent, although no regional differences were observed. Conclusions: The Kernel Flow has promise as an intraoperative neuromonitoring device. Although regional sensitivity was affected by hair color and density, enhanced depth sensitivity of trNIRS was able to resolve differences in scalp and brain oxygenation responses in both protocols.


Cerebrovascular Circulation , Spectroscopy, Near-Infrared , Humans , Spectroscopy, Near-Infrared/methods , Spectroscopy, Near-Infrared/instrumentation , Female , Male , Adult , Cerebrovascular Circulation/physiology , Hemodynamics/physiology , Oximetry/methods , Oximetry/instrumentation , Oxygen/blood , Oxygen/metabolism , Brain/diagnostic imaging , Brain/blood supply , Equipment Design
3.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article En | MEDLINE | ID: mdl-38710669

OBJECTIVES: The objective of this analysis was to assess the normal haemodynamic performance of contemporary surgical aortic valves at 1 year postimplant in patients undergoing surgical aortic valve replacement for significant valvular dysfunction. By pooling data from 4 multicentre studies, this study will contribute to a better understanding of the effectiveness of surgical aortic valve replacement procedures, aiding clinicians and researchers in making informed decisions regarding valve selection and patient management. METHODS: Echocardiograms were assessed by a single core laboratory. Effective orifice area, dimensionless velocity index, mean aortic gradient, peak aortic velocity and stroke volume were evaluated. RESULTS: The cohort included 2958 patients. Baseline age in the studies ranged from 70.1 ± 9.0 to 83.3 ± 6.4 years, and Society of Thoracic Surgeons risk of mortality was 1.9 ± 0.7 to 7.5 ± 3.4%. Twenty patients who had received a valve model implanted in fewer than 10 cases were excluded. Ten valve models (all tissue valves; n = 2938 patients) were analysed. At 1 year, population mean effective orifice area ranged from 1.46 ± 0.34 to 2.12 ± 0.59 cm2, and dimensionless velocity index, from 0.39 ± 0.07 to 0.56 ± 0.15. The mean gradient ranged from 8.6 ± 3.4 to 16.1 ± 6.2 mmHg with peak aortic velocity of 1.96 ± 0.39 to 2.65 ± 0.47 m/s. Stroke volume was 75.3 ± 19.6 to 89.8 ± 24.3 ml. CONCLUSIONS: This pooled cohort is the largest to date of contemporary surgical aortic valves with echocardiograms analysed by a single core lab. Overall haemodynamic performance at 1 year ranged from good to excellent. These data can serve as a benchmark for other studies and may be useful to evaluate the performance of bioprosthetic surgical valves over time. CLINICAL TRIAL REGISTRATION NUMBER: NCT02088554, NCT02701283, NCT01586910 and NCT01531374.


Aortic Valve , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Hemodynamics , Humans , Hemodynamics/physiology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aged , Female , Male , Aged, 80 and over , Heart Valve Prosthesis Implantation/methods , Echocardiography , Middle Aged , Prosthesis Design
5.
J Biomech ; 168: 112124, 2024 May.
Article En | MEDLINE | ID: mdl-38701696

Congenital arterial stenosis such as supravalvar aortic stenosis (SVAS) are highly prevalent in Williams syndrome (WS) and other arteriopathies pose a substantial health risk. Conventional tools for severity assessment, including clinical findings and pressure gradient estimations, often fall short due to their susceptibility to transient physiological changes and disease stage influences. Moreover, in the pediatric population, the severity of these and other congenital heart defects (CHDs) often restricts the applicability of invasive techniques for obtaining crucial physiological data. Conversely, evaluating CHDs and their progression requires a comprehensive understanding of intracardiac blood flow. Current imaging modalities, such as blood speckle imaging (BSI) and four-dimensional magnetic resonance imaging (4D MRI) face limitations in resolving flow data, especially in cases of elevated flow velocities. To address these challenges, we devised a computational framework employing zero-dimensional (0D) lumped parameter models coupled with patient-specific reconstructed geometries pre- and post-surgical intervention to execute computational fluid dynamic (CFD) simulations. This framework facilitates the analysis and visualization of intricate blood flow patterns, offering insights into geometry and flow dynamics alterations impacting cardiac function. In this study, we aim to assess the efficacy of surgical intervention in correcting an extreme aortic defect in a patient with WS, leading to reductions in wall shear stress (WSS), maximum velocity magnitude, pressure drop, and ultimately a decrease in cardiac workload.


Hemodynamics , Models, Cardiovascular , Williams Syndrome , Humans , Williams Syndrome/physiopathology , Williams Syndrome/diagnostic imaging , Hemodynamics/physiology , Heart Defects, Congenital/physiopathology , Heart Defects, Congenital/complications , Heart Defects, Congenital/diagnostic imaging , Aorta/physiopathology , Aorta/diagnostic imaging , Blood Flow Velocity/physiology , Male , Female , Computer Simulation
6.
Sensors (Basel) ; 24(9)2024 May 03.
Article En | MEDLINE | ID: mdl-38733027

Heart failure (HF) is a complex clinical syndrome associated with significant morbidity, mortality, and healthcare costs. It is characterized by various structural and/or functional abnormalities of the heart, resulting in elevated intracardiac pressure and/or inadequate cardiac output at rest and/or during exercise. These dysfunctions can originate from a variety of conditions, including coronary artery disease, hypertension, cardiomyopathies, heart valve disorders, arrhythmias, and other lifestyle or systemic factors. Identifying the underlying cause is crucial for detecting reversible or treatable forms of HF. Recent epidemiological studies indicate that there has not been an increase in the incidence of the disease. Instead, patients seem to experience a chronic trajectory marked by frequent hospitalizations and stagnant mortality rates. Managing these patients requires a multidisciplinary approach that focuses on preventing disease progression, controlling symptoms, and preventing acute decompensations. In the outpatient setting, patient self-care plays a vital role in achieving these goals. This involves implementing necessary lifestyle changes and promptly recognizing symptoms/signs such as dyspnea, lower limb edema, or unexpected weight gain over a few days, to alert the healthcare team for evaluation of medication adjustments. Traditional methods of HF monitoring, such as symptom assessment and periodic clinic visits, may not capture subtle changes in hemodynamics. Sensor-based technologies offer a promising solution for remote monitoring of HF patients, enabling early detection of fluid overload and optimization of medical therapy. In this review, we provide an overview of the CardioMEMS device, a novel sensor-based system for pulmonary artery pressure monitoring in HF patients. We discuss the technical aspects, clinical evidence, and future directions of CardioMEMS in HF management.


Heart Failure , Humans , Heart Failure/therapy , Heart Failure/physiopathology , Cardiology/methods , Monitoring, Physiologic/methods , Monitoring, Physiologic/instrumentation , Disease Management , Hemodynamics/physiology
8.
Khirurgiia (Mosk) ; (5): 95-100, 2024.
Article Ru | MEDLINE | ID: mdl-38785244

A personalized approach with attention to anamnesis and specific symptoms is necessary in patients with internal carotid artery tortuosity. Neuroimaging (especially before elective surgery) or functional stress tests following ultrasound of supra-aortic vessels may be necessary depending on medical history and complaints. In addition to standard Doppler ultrasound, these patients should undergo rotational and orthostatic transformation tests. We analyze changes in shape and hemodynamic parameters within the tortuosity area in various body positions. This is especially valuable for patients with concomitant carotid artery stenosis. The article presents a clinical case illustrating the importance of such approach.


Carotid Artery, Internal , Carotid Stenosis , Humans , Carotid Artery, Internal/diagnostic imaging , Carotid Artery, Internal/abnormalities , Carotid Artery, Internal/physiopathology , Carotid Stenosis/physiopathology , Carotid Stenosis/complications , Carotid Stenosis/diagnosis , Carotid Stenosis/surgery , Male , Female , Middle Aged , Ultrasonography, Doppler/methods , Hemodynamics/physiology , Atherosclerosis/complications , Atherosclerosis/diagnosis , Atherosclerosis/physiopathology , Vascular Malformations/diagnosis , Vascular Malformations/complications , Vascular Malformations/physiopathology , Aged , Arteries/abnormalities , Joint Instability , Skin Diseases, Genetic
9.
Curr Probl Cardiol ; 49(7): 102619, 2024 Jul.
Article En | MEDLINE | ID: mdl-38723794

OBJECTIVE: This systematic review aims to assess the comparative effectiveness and safety of temporary mechanical circulatory support (MCS) devices in various subgroups of patients with acute cardiogenic shock, providing insights for personalized clinical decision-making. METHODS: We conducted a comprehensive search across major databases to identify studies that reported on the use of temporary MCS devices like TandemHeart, Impella, and VA-ECMO in acute cardiogenic shock. Special attention was given to subgroup analyses based on etiologies of shock, patient demographics, and comorbid conditions. RESULTS: Our analysis revealed that while devices like TandemHeart and Impella offer significant hemodynamic support, their effectiveness and safety profiles vary across different patient subgroups. VA-ECMO demonstrated the highest flow rates and potential for mortality benefits but requires careful management due to associated risks. The lack of randomized controlled trials in specific patient subgroups highlights a gap in the current literature, underscoring the need for targeted research. CONCLUSION: The review underscores the necessity of a personalized approach in selecting temporary MCS devices for patients with acute cardiogenic shock, guided by specific patient characteristics and clinical scenarios. Future research should focus on addressing the identified evidence gaps through well-designed studies that provide robust subgroup-specific data, enabling clinicians to optimize treatment strategies and improve patient outcomes in this critical care context.


Extracorporeal Membrane Oxygenation , Heart-Assist Devices , Shock, Cardiogenic , Shock, Cardiogenic/therapy , Shock, Cardiogenic/mortality , Humans , Heart-Assist Devices/adverse effects , Extracorporeal Membrane Oxygenation/methods , Extracorporeal Membrane Oxygenation/adverse effects , Treatment Outcome , Acute Disease , Hemodynamics/physiology
10.
Sci Rep ; 14(1): 11649, 2024 05 22.
Article En | MEDLINE | ID: mdl-38773192

Recent research has revealed that hemodynamic changes caused by lung recruitment maneuvers (LRM) with continuous positive airway pressure can be used to identify fluid responders. We investigated the usefulness of stepwise LRM with increasing positive end-expiratory pressure and constant driving pressure for predicting fluid responsiveness in patients under lung protective ventilation (LPV). Forty-one patients under LPV were enrolled when PPV values were in a priori considered gray zone (4% to 17%). The FloTrac-Vigileo device measured stroke volume variation (SVV) and stroke volume (SV), while the patient monitor measured pulse pressure variation (PPV) before and at the end of stepwise LRM and before and 5 min after fluid challenge (6 ml/kg). Fluid responsiveness was defined as a ≥ 15% increase in the SV or SV index. Seventeen were fluid responders. The areas under the curve for the augmented values of PPV and SVV, as well as the decrease in SV by stepwise LRM to identify fluid responders, were 0.76 (95% confidence interval, 0.61-0.88), 0.78 (0.62-0.89), and 0.69 (0.53-0.82), respectively. The optimal cut-offs for the augmented values of PPV and SVV were > 18% and > 13%, respectively. Stepwise LRM -generated augmented PPV and SVV predicted fluid responsiveness under LPV.


Fluid Therapy , Operating Rooms , Humans , Male , Female , Aged , Middle Aged , Fluid Therapy/methods , Positive-Pressure Respiration/methods , Respiration, Artificial/methods , Lung/physiology , Lung/physiopathology , Stroke Volume/physiology , Hemodynamics/physiology
11.
Sci Rep ; 14(1): 10242, 2024 05 03.
Article En | MEDLINE | ID: mdl-38702415

Cerebral infra-slow oscillation (ISO) is a source of vasomotion in endogenic (E; 0.005-0.02 Hz), neurogenic (N; 0.02-0.04 Hz), and myogenic (M; 0.04-0.2 Hz) frequency bands. In this study, we quantified changes in prefrontal concentrations of oxygenated hemoglobin (Δ[HbO]) and redox-state cytochrome c oxidase (Δ[CCO]) as hemodynamic and metabolic activity metrics, and electroencephalogram (EEG) powers as electrophysiological activity, using concurrent measurements of 2-channel broadband near-infrared spectroscopy and EEG on the forehead of 22 healthy participants at rest. After preprocessing, the multi-modality signals were analyzed using generalized partial directed coherence to construct unilateral neurophysiological networks among the three neurophysiological metrics (with simplified symbols of HbO, CCO, and EEG) in each E/N/M frequency band. The links in these networks represent neurovascular, neurometabolic, and metabolicvascular coupling (NVC, NMC, and MVC). The results illustrate that the demand for oxygen by neuronal activity and metabolism (EEG and CCO) drives the hemodynamic supply (HbO) in all E/N/M bands in the resting prefrontal cortex. Furthermore, to investigate the effect of transcranial photobiomodulation (tPBM), we performed a sham-controlled study by delivering an 800-nm laser beam to the left and right prefrontal cortex of the same participants. After performing the same data processing and statistical analysis, we obtained novel and important findings: tPBM delivered on either side of the prefrontal cortex triggered the alteration or reversal of directed network couplings among the three neurophysiological entities (i.e., HbO, CCO, and EEG frequency-specific powers) in the physiological network in the E and N bands, demonstrating that during the post-tPBM period, both metabolism and hemodynamic supply drive electrophysiological activity in directed network coupling of the prefrontal cortex (PFC). Overall, this study revealed that tPBM facilitates significant modulation of the directionality of neurophysiological networks in electrophysiological, metabolic, and hemodynamic activities.


Electroencephalography , Prefrontal Cortex , Spectroscopy, Near-Infrared , Humans , Prefrontal Cortex/physiology , Prefrontal Cortex/metabolism , Male , Adult , Female , Spectroscopy, Near-Infrared/methods , Low-Level Light Therapy/methods , Young Adult , Rest/physiology , Oxyhemoglobins/metabolism , Electron Transport Complex IV/metabolism , Hemodynamics/physiology , Nerve Net/physiology , Nerve Net/metabolism
12.
Crit Care Explor ; 6(5): e1083, 2024 May.
Article En | MEDLINE | ID: mdl-38694846

OBJECTIVES: This prospective cohort study aimed to investigate changes in intracranial pressure (ICP) and cerebral hemodynamics in infants with congenital heart disease undergoing the Glenn procedure, focusing on the relationship between superior vena cava pressure and estimated ICP. DESIGN: A single-center prospective cohort study. SETTING: The study was conducted in a cardiac center over 4 years (2019-2022). PATIENTS: Twenty-seven infants with congenital heart disease scheduled for the Glenn procedure were included in the study, and detailed patient demographics and primary diagnoses were recorded. INTERVENTIONS: Transcranial Doppler (TCD) ultrasound examinations were performed at three time points: baseline (preoperatively), postoperative while ventilated (within 24-48 hr), and at discharge. TCD parameters, blood pressure, and pulmonary artery pressure were measured. MEASUREMENTS AND MAIN RESULTS: TCD parameters included systolic flow velocity, diastolic flow velocity (dFV), mean flow velocity (mFV), pulsatility index (PI), and resistance index. Estimated ICP and cerebral perfusion pressure (CPP) were calculated using established formulas. There was a significant postoperative increase in estimated ICP from 11 mm Hg (interquartile range [IQR], 10-16 mm Hg) to 15 mm Hg (IQR, 12-21 mm Hg) postoperatively (p = 0.002) with a trend toward higher CPP from 22 mm Hg (IQR, 14-30 mm Hg) to 28 mm Hg (IQR, 22-38 mm Hg) postoperatively (p = 0.1). TCD indices reflected alterations in cerebral hemodynamics, including decreased dFV and mFV and increased PI. Intracranial hemodynamics while on positive airway pressure and after extubation were similar. CONCLUSIONS: Glenn procedure substantially increases estimated ICP while showing a trend toward higher CPP. These findings underscore the intricate interaction between venous pressure and cerebral hemodynamics in infants undergoing the Glenn procedure. They also highlight the remarkable complexity of cerebrovascular autoregulation in maintaining stable brain perfusion under these circumstances.


Cerebrovascular Circulation , Heart Defects, Congenital , Hemodynamics , Intracranial Pressure , Ultrasonography, Doppler, Transcranial , Humans , Infant , Prospective Studies , Female , Male , Intracranial Pressure/physiology , Heart Defects, Congenital/surgery , Heart Defects, Congenital/physiopathology , Heart Defects, Congenital/diagnostic imaging , Cerebrovascular Circulation/physiology , Ultrasonography, Doppler, Transcranial/methods , Hemodynamics/physiology , Cohort Studies , Fontan Procedure , Vena Cava, Superior/physiopathology , Vena Cava, Superior/diagnostic imaging
13.
J Cardiothorac Surg ; 19(1): 284, 2024 May 10.
Article En | MEDLINE | ID: mdl-38730503

INTRODUCTION: Post liver transplantation (LT) patients endure high morbidity rate of multi-organ ischemic symptoms following reperfusion. We hypothesize that enhanced external counterpulsation (EECP) as a typical non-invasive assisted circulation procedure, which can efficiently inhibit the relative ischemic symptoms via the systemic improvement of hemodynamics. CASE PRESENTATION: A 51-year-old male patient, 76 kg, 172 cm, received orthotopic LT surgery for viral hepatitis B induced acute-on-chronic liver failure hepatic failure. His medical records revealed ischemic symptoms in multi-organ at the time of hospital discharge, including headache, refractory insomnia, abdominal paralysis, and lower limb pain. The EECP treatment was introduced for assisted rehabilitation and to improve the postoperative quality of life. Doppler Ultrasound examination showed significant augmentation of blood flow volume in the carotid arteries, the hepatic artery, the portal vein and the femoral artery during EECP intervention. A standard 35-hour EECP treatment led to significant improvement in quality of life, e.g. sleep quality and walking ability. CONCLUSION: We report a case of multi-organ ischemic symptoms in a post LT patient. EECP treatment can significantly improve the quality of life via the systematic promotion of hemodynamics.


Counterpulsation , Hemodynamics , Liver Transplantation , Humans , Male , Middle Aged , Counterpulsation/methods , Hemodynamics/physiology , Postoperative Complications/therapy , Quality of Life , Ischemia/surgery , Ischemia/physiopathology
14.
PLoS One ; 19(5): e0302828, 2024.
Article En | MEDLINE | ID: mdl-38722930

Cupping therapy is a popular intervention for improving muscle recovery after exercise although clinical evidence is weak. Previous studies demonstrated that cupping therapy may improve microcirculation of the soft tissue to accelerate tissue healing. However, it is unclear whether the cupping size could affect the spatial hemodynamic response of the treated muscle. The objective of this study was to use 8-channel near-infrared spectroscopy to assess this clinical question by assessing the effect of 3 cupping sizes (35, 40, and 45 mm in inner diameter of the circular cup) under -300 mmHg for 5 min on the muscle hemodynamic response from the area inside and outside the cup, including oxyhemoglobin and deoxy-hemoglobin in 18 healthy adults. Two-way factorial design was used to assess the interaction between the cupping size (35, 40, and 45 mm) and the location (inside and outside the cup) and the main effects of the cupping size and the location. The two-way repeated measures ANOVA demonstrated an interaction between the cupping size and the location in deoxy-hemoglobin (P = 0.039) but no interaction in oxyhemoglobin (P = 0.100), and a main effect of the cup size (P = 0.001) and location (P = 0.023) factors in oxyhemoglobin. For the cupping size factor, the 45-mm cup resulted in a significant increase in oxyhemoglobin (5.738±0.760 µM) compared to the 40-mm (2.095±0.312 µM, P<0.001) and 35-mm (3.134±0.515 µM, P<0.01) cup. Our findings demonstrate that the cupping size and location factors affect the muscle hemodynamic response, and the use of multi-channel near-infrared spectroscopy may help understand benefits of cupping therapy on managing musculoskeletal impairment.


Hemodynamics , Muscle, Skeletal , Oxyhemoglobins , Spectroscopy, Near-Infrared , Humans , Spectroscopy, Near-Infrared/methods , Male , Hemodynamics/physiology , Female , Adult , Muscle, Skeletal/physiology , Muscle, Skeletal/blood supply , Oxyhemoglobins/metabolism , Oxyhemoglobins/analysis , Cupping Therapy/methods , Young Adult , Hemoglobins/metabolism
15.
Sci Rep ; 14(1): 11287, 2024 05 17.
Article En | MEDLINE | ID: mdl-38760449

Spectrum power analysis in the low frequency oscillations (LFO) region of functional near infrared spectroscopy (fNIRS) is a promising method to deliver information about brain activation and therefore might be used for prognostication in patients with disorders of consciousness in the neurocritical care unit alongside with established methods. In this study, we measure the cortical hemodynamic response measured by fNIRS in the LFO region following auditory and somatosensory stimulation in healthy subjects. The significant hemodynamic reaction in the contralateral hemisphere correlation with the physiologic electric response suggests neurovascular coupling. In addition, we investigate power spectrum changes in steady state measurements of cerebral death patients and healthy subjects in the LFO region, the frequency of the heartbeat and respiration. The spectral power within the LFO region was lower in the patients with cerebral death compared to the healthy subjects, whereas there were no differences in spectral power for physiological activities such as heartbeat and respiration rate. This finding indicates the cerebral origin of our low frequency measurements. Therefore, LFO measurements are a potential method to detect brain activation in patients with disorders of consciousness and cerebral death. However, further studies in patients are needed to investigate its potential clinical use.


Brain Death , Neurovascular Coupling , Spectroscopy, Near-Infrared , Humans , Male , Female , Adult , Neurovascular Coupling/physiology , Spectroscopy, Near-Infrared/methods , Brain Death/physiopathology , Middle Aged , Hemodynamics/physiology , Aged , Brain/physiopathology , Brain/physiology , Brain/diagnostic imaging , Heart Rate/physiology
16.
Clin Radiol ; 79(6): e842-e853, 2024 Jun.
Article En | MEDLINE | ID: mdl-38582632

AIM: We design a feasibility study to obtain a set of metabolic-hemodynamic habitats for tackling tumor spatial metabolic patterns with hemodynamic information. MATERIALS AND METHODS: Preoperative data from 69 high-grade gliomas (HGG) patients with subsequent histologic confirmation of HGG were prospectively collected (January 2016 to March 2020) after concurrent chemoradiotherapy (CCRT). Four vascular habitats were automatically segmented by multiparametric magnetic resonance imaging (MRI). The metabolic information, either at enhancing or edema tumor regions, was obtained by two neuroradiologists. The relative habitat volumes were used for weight estimation procedures for computing the coefficients of a linear regression model using weighted least squares (WLS) for metabolite semiquantifications (i.e. the Cho/NAA ratio and the Cho/Cr ratio) at vascular habitats. Multivariate Cox proportional hazard regression analyses are used to obtain the odds ratio (OR) and develop a nomogram using weighted estimators corresponding to each covariate derived from Cox regression coefficients. RESULTS: There was a strongly correlation between perfusion indexes and the Cho/Cr ratio (rCBV, r=0.71) or Cho/NAA ratio (rCBV, r=0.66) at high-angiogenic enhancing tumor habitats (HAT) habitat. Compared isocitrate dehydrogenase (IDH) mutation to their wild type, the IDH wild type had significantly decreased Cho/Cr ratio (IDH mutation: Cho/Cr ratio = 2.44 ± 0.33, IDH wildtype: Cho/Cr ratio = 2.66 ± 0.36, p=0.02) and Cho/NAA ratio (IDH mutation: Cho/Cr ratio = 4.59 ± 0.61, IDH wildtype: Cho/Cr ratio = 4.99 ± 0.66, p=0.022) at the HAT. The C-index for the median progression-free survival (PFS) prediction was 0.769 for the Cho/NAA nomogram and 0.747 for the Cho/Cr nomogram through 1000 bootstrapping validation. CONCLUSIONS: Our findings suggest that spatial metabolism combined with hemodynamic heterogeneity is associated with individual PFS to HGG patients post-CCRT.


Brain Neoplasms , Feasibility Studies , Glioma , Hemodynamics , Progression-Free Survival , Humans , Glioma/diagnostic imaging , Glioma/pathology , Glioma/therapy , Female , Male , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/therapy , Brain Neoplasms/pathology , Middle Aged , Hemodynamics/physiology , Adult , Prospective Studies , Aged , Multiparametric Magnetic Resonance Imaging/methods
17.
J Am Heart Assoc ; 13(9): e032520, 2024 May 07.
Article En | MEDLINE | ID: mdl-38686858

BACKGROUND: Symptomatic limitations in apical hypertrophic cardiomyopathy may occur because of diastolic dysfunction with resultant elevated left ventricular filling pressures, cardiac output limitation to exercise, pulmonary hypertension (PH), valvular abnormalities, and/or arrhythmias. In this study, the authors aimed to describe invasive cardiac hemodynamics in a cohort of patients with apical hypertrophic cardiomyopathy. METHODS AND RESULTS: Patients presenting to a comprehensive hypertrophic cardiomyopathy center with apical hypertrophic cardiomyopathy were identified (n=542) and those who underwent invasive hemodynamic catheterization (n=47) were included in the study. Of these, 10 were excluded due to postmyectomy status or incomplete hemodynamic data. The mean age was 56±18 years, 16 (43%) were women, and ejection fraction was preserved (≥50%) in 32 (91%) patients. The most common indication for catheterization was dyspnea (48%) followed by suspected PH (13%), and preheart transplant evaluation (10%). Elevated left ventricular filling pressures at rest or exercise were present in 32 (86%) patients. PH was present in 30 (81%) patients, with 6 (20%) also having right-sided heart failure. Cardiac index was available in 25 (86%) patients with elevated resting filling pressures. Of these, 19 (76%) had reduced cardiac index and all 6 with right-sided heart failure had reduced cardiac index. Resting hemodynamics were normal in 8 of 37 (22%) patients, with 5 during exercise; 3 of 5 (60%) patients had exercise-induced elevation in left ventricular filling pressures. CONCLUSIONS: In patients with apical hypertrophic cardiomyopathy undergoing invasive hemodynamic cardiac catheterization, 86% had elevated left ventricular filling pressures at rest or with exercise, 81% had PH, and 20% of those with PH had concomitant right-sided heart failure.


Cardiac Catheterization , Cardiomyopathy, Hypertrophic , Hemodynamics , Humans , Female , Cardiomyopathy, Hypertrophic/physiopathology , Cardiomyopathy, Hypertrophic/complications , Middle Aged , Male , Aged , Hemodynamics/physiology , Adult , Ventricular Function, Left/physiology , Stroke Volume/physiology , Retrospective Studies , Hypertension, Pulmonary/physiopathology , Hypertension, Pulmonary/diagnosis , Apical Hypertrophic Cardiomyopathy
18.
Cardiovasc Intervent Radiol ; 47(5): 533-542, 2024 May.
Article En | MEDLINE | ID: mdl-38565717

PURPOSE: In arterial disease, the presence of two or more serial stenotic lesions is common. For mild lesions, it is difficult to predict whether their combined effect is hemodynamically significant. This study assessed the hemodynamic significance of idealized serial stenotic lesions by simulating their hemodynamic interaction in a computational flow model. MATERIALS AND METHODS: Flow was simulated with SimVascular software in 34 serial lesions, using moderate (15 mL/s) and high (30 mL/s) flow rates. Combinations of one concentric and two eccentric lesions, all 50% area reduction, were designed with variations in interstenotic distance and in relative direction of eccentricity. Fluid and fluid-structure simulations were performed to quantify the combined pressure gradient. RESULTS: At a moderate flow rate, the combined pressure gradient of two lesions ranged from 3.8 to 7.7 mmHg, which increased to a range of 12.5-24.3 mmHg for a high flow rate. Eccentricity caused an up to two-fold increase in pressure gradient relative to concentric lesions. At a high flow rate, the combined pressure gradient for serial eccentric lesions often exceeded the sum of the individual lesions. The relative direction of eccentricity altered the pressure gradient by 15-25%. The impact of flow pulsatility and wall deformability was minor. CONCLUSION: This flow simulation study revealed that lesion eccentricity is an adverse factor in the hemodynamic significance of isolated stenotic lesions and in serial stenotic lesions. Two 50% lesions that are individually non-significant can combine more often than thought to hemodynamic significance in hyperemic conditions.


Computer Simulation , Hemodynamics , Humans , Hemodynamics/physiology , Models, Cardiovascular , Blood Flow Velocity , Coronary Stenosis/physiopathology , Coronary Stenosis/diagnostic imaging
19.
Circ Cardiovasc Imaging ; 17(4): e016104, 2024 Apr.
Article En | MEDLINE | ID: mdl-38567518

BACKGROUND: The Fontan operation is a palliative technique for patients born with single ventricle heart disease. The superior vena cava (SVC), inferior vena cava (IVC), and hepatic veins are connected to the pulmonary arteries in a total cavopulmonary connection by an extracardiac conduit or a lateral tunnel connection. A balanced hepatic flow distribution (HFD) to both lungs is essential to prevent pulmonary arteriovenous malformations and cyanosis. HFD is highly dependent on the local hemodynamics. The effect of age-related changes in caval inflows on HFD was evaluated using cardiac magnetic resonance data and patient-specific computational fluid dynamics modeling. METHODS: SVC and IVC flow from 414 patients with Fontan were collected to establish a relationship between SVC:IVC flow ratio and age. Computational fluid dynamics modeling was performed in 60 (30 extracardiac and 30 lateral tunnel) patient models to quantify the HFD that corresponded to patient ages of 3, 8, and 15 years, respectively. RESULTS: SVC:IVC flow ratio inverted at ≈8 years of age, indicating a clear shift to lower body flow predominance. Our data showed that variation of HFD in response to age-related changes in caval inflows (SVC:IVC, 2, 1, and 0.5 corresponded to ages, 3, 8, and 15+, respectively) was not significant for extracardiac but statistically significant for lateral tunnel cohorts. For all 3 caval inflow ratios, a positive correlation existed between the IVC flow distribution to both the lungs and the HFD. However, as the SVC:IVC ratio changed from 2 to 0.5 (age, 3-15+) years, the correlation's strength decreased from 0.87 to 0.64, due to potential flow perturbation as IVC flow momentum increased. CONCLUSIONS: Our analysis provided quantitative insights into the impact of the changing caval inflows on Fontan's long-term HFD, highlighting the importance of SVC:IVC variations over time on Fontan's long-term hemodynamics. These findings broaden our understanding of Fontan hemodynamics and patient outcomes.


Fontan Procedure , Heart Defects, Congenital , Humans , Child, Preschool , Child , Adolescent , Vena Cava, Superior/diagnostic imaging , Vena Cava, Superior/surgery , Vena Cava, Superior/physiology , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/surgery , Liver/diagnostic imaging , Hemodynamics/physiology , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/surgery , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery
20.
ASAIO J ; 70(5): 338-347, 2024 May 01.
Article En | MEDLINE | ID: mdl-38557701

We characterize the anatomy and function of never before studied total artificial hearts (TAHs) using established methods for testing mechanical circulatory support (MCS) devices. A historical review of TAHs is also presented to aid in benchmarking performance metrics. Six TAHs, ranging from spooky Halloween beating hearts to a cute colorful plush heart, were imaged, instrumented (mock flow loops) to measure their pressure, volume, and flow, and qualitatively evaluated by 3rd party cardiac surgeons for anatomical accuracy and surgical considerations. Imaging of Claw, Beating, and Frankenstein TAHs revealed internal motors, circuit boards, and speakers. Gummy TAH was ranked favorite TAH for tactile realism, while Frankenstein TAH had the most favorable audible/visual indicators, including an illuminated Jacob's Ladder. Beating TAH demonstrated superior pulsatile hemodynamic performance compared to Claw TAH (16mL vs 1.3mL stroke volume). Light Up TAH and Gummy TAH functioned only as passive compliance chambers. Cute TAH rapidly exsanguinated due to its porosity (-3.0 L/min flow). These TAHs demonstrated a wide range of anatomical accuracy, surgeon appeal, unique features, and hemodynamic performance. While Claw TAH and Beating TAH successfully generated a modicum of pulsatility, we recommend the clinical community continue to support pre-clinical development of emerging or use of clinically-approved TAHs.


Heart, Artificial , Hemodynamics , Hemodynamics/physiology , Humans
...