Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 3.984
4.
Eur J Gastroenterol Hepatol ; 36(7): 845-849, 2024 Jul 01.
Article En | MEDLINE | ID: mdl-38829942

BACKGROUND: Meckel diverticulum (MD) is an important cause of gastrointestinal bleeding in children. Small bowel capsule endoscopy (SBCE) is a first-line examination method applied to patients with obscure gastrointestinal bleeding, but there are few studies on its application in children with MD. This article aims to provide evidence in favor of the auxiliary diagnosis of MD in children by analyzing its characteristics using SBCE. METHODS: We retrospectively collected the clinical data of patients with suspected MD. RESULTS: A total of 58 children were included in this study. All 58 children presented overt gastrointestinal bleeding (bloody stool or melena). Capsule endoscopy identified protruding lesions in 2 cases, double-lumen changes in 30 cases (all considered as MD), vascular lesions in 7 cases, intestinal mucosal inflammatory lesions in 3 cases, ulcers or erosion in 3 cases, and no obvious abnormalities in SBCE in 12 cases. Both SBCE and technetium-99 scans were performed for 24 cases, 22 of which were diagnosed MD by their combined results, giving a diagnostic coincidence rate of 91.7%. Eight cases were highly suspected as MD but were negative for the technetium-99 scan and positive for SBCE. CONCLUSION: SBCE has high accuracy in the diagnosis of MD in children, especially when performed in combination with a technetium-99 scan, which can greatly improve the diagnostic rate of MD in children.


Capsule Endoscopy , Gastrointestinal Hemorrhage , Meckel Diverticulum , Humans , Meckel Diverticulum/complications , Meckel Diverticulum/diagnostic imaging , Meckel Diverticulum/diagnosis , Capsule Endoscopy/methods , Male , Female , Retrospective Studies , Child , Child, Preschool , Gastrointestinal Hemorrhage/etiology , Adolescent , Infant , Intestine, Small/diagnostic imaging , Intestine, Small/pathology , Predictive Value of Tests , Radionuclide Imaging , Radiopharmaceuticals
6.
Medicine (Baltimore) ; 103(20): e38119, 2024 May 17.
Article En | MEDLINE | ID: mdl-38758917

Device assisted enteroscopy (DAE) like the double balloon enteroscopy (DBE) and single balloon enteroscopy (SBE) are postulated to ease small bowel examination and performance of therapy. However, studies comparing the effectiveness of these 2 modalities have yielded varying results. The aim of this study is to compare the efficacy and safety of SBE and DBE. We retrospectively reviewed records of patients who underwent DBE (n = 82) or SBE (n = 45) for small bowel exam in our unit from January 2014 to January 2022. Our primary outcomes were to compare the technical success and diagnostic success rates between DBE and SBE. Our secondary outcomes were to compare the therapeutic success, and complication rates. The main indications were suspected GI bleeding (DBE 41.5% vs SBE 48.9%), iron deficiency anemia (DBE 9.8% vs SBE 4.4%) and small bowel lesions (DBE 28.0% vs SBE 44.4%) detected either from prior capsule endoscopy or radiological imaging. Majority of the enteroscopy exam was by antegrade approach (DBE 67.1% vs SBE 77.8%). We found no significant difference in the technical success (DBE 95.1% vs SBE 97.8%, P = .46), diagnostic success (DBE 69.5% vs SBE 77.8%, P = .36) and the therapeutic success rate (DBE 63.2% vs SBE 54.3%, P = .09) between the groups. Complications occurred in 1 case from each group (mucosal tear). None of the complications were major. In patients who underwent enteroscopy, the diagnostic and therapeutic performance of SBE is similar to DBE. Both procedures were safe with low complication rates.


Double-Balloon Enteroscopy , Gastrointestinal Hemorrhage , Intestine, Small , Single-Balloon Enteroscopy , Humans , Double-Balloon Enteroscopy/methods , Double-Balloon Enteroscopy/adverse effects , Female , Retrospective Studies , Male , Middle Aged , Single-Balloon Enteroscopy/methods , Intestine, Small/diagnostic imaging , Adult , Gastrointestinal Hemorrhage/diagnosis , Aged , Intestinal Diseases/diagnosis , Intestinal Diseases/diagnostic imaging , Anemia, Iron-Deficiency/diagnosis
7.
PLoS One ; 19(5): e0295774, 2024.
Article En | MEDLINE | ID: mdl-38713694

BACKGROUND: Magnetically assisted capsule endoscopy (MACE) showed the feasibility for upper gastrointestinal examination. To further enhance the performance of conventional MACE, it is necessary to provide quality-improved and three-dimensional images. The aim of this clinical study was to determine the efficacy and safety of novel three-dimensional MACE (3D MACE) for upper gastrointestinal and small bowel examination at once. METHODS: This was a prospective, single-center, non-randomized, and sequential examination study (KCT0007114) at Dongguk University Ilsan Hospital. Adult patients who visited for upper endoscopy were included. The study protocol was conducted in two stages. First, upper gastrointestinal examination was performed using 3D MACE, and a continuous small bowel examination was performed by conventional method of capsule endoscopy. Two hours later, an upper endoscopy was performed for comparison with 3D MACE examination. The primary outcome was confirmation of major gastric structures (esophagogastric junction, cardia/fundus, body, angle, antrum, and pylorus). Secondary outcomes were confirmation of esophagus and duodenal bulb, accuracy for gastric lesions, completion of small bowel examination, 3D image reconstruction of gastric lesion, and safety. RESULTS: Fifty-five patients were finally enrolled. The examination time of 3D MACE was 14.84 ± 3.02 minutes and upper endoscopy was 5.22 ± 2.39 minutes. The confirmation rate of the six major gastric structures was 98.6% in 3D MACE and 100% in upper endoscopy. Gastric lesions were identified in 43 patients during 3D MACE, and 40 patients during upper endoscopy (Sensitivity 0.97). 3D reconstructed images were acquired for all lesions inspected by 3D MACE. The continuous small bowel examination by 3D MACE was completed in 94.5%. 3D MACE showed better overall satisfaction (3D MACE 9.55 ± 0.79 and upper endoscopy 7.75 ± 2.34, p<0.0001). There were no aspiration or significant adverse event or capsule retention in the 3D MACE examination. CONCLUSIONS: Novel 3D MACE system is more advanced diagnostic modality than the conventional MACE. And it is possible to perform serial upper gastrointestinal and small bowel examination as a non-invasive and one-step test. It would be also served as a bridge to pan-endoscopy.


Capsule Endoscopy , Imaging, Three-Dimensional , Intestine, Small , Humans , Capsule Endoscopy/methods , Capsule Endoscopy/adverse effects , Male , Female , Intestine, Small/diagnostic imaging , Intestine, Small/pathology , Middle Aged , Imaging, Three-Dimensional/methods , Prospective Studies , Adult , Aged , Upper Gastrointestinal Tract/diagnostic imaging , Upper Gastrointestinal Tract/pathology
8.
World J Gastroenterol ; 30(18): 2482-2484, 2024 May 14.
Article En | MEDLINE | ID: mdl-38764765

The present letter to the editor is related to the study with the title "Automatic detection of small bowel (SB) lesions with different bleeding risk based on deep learning models". Capsule endoscopy (CE) is the main tool to assess SB diseases but it is a time-consuming procedure with a significant error rate. The development of artificial intelligence (AI) in CE could simplify physicians' tasks. The novel deep learning model by Zhang et al seems to be able to identify various SB lesions and their bleeding risk, and it could pave the way to next perspective studies to better enhance the diagnostic support of AI in the detection of different types of SB lesions in clinical practice.


Artificial Intelligence , Capsule Endoscopy , Deep Learning , Gastrointestinal Hemorrhage , Intestine, Small , Humans , Capsule Endoscopy/methods , Gastrointestinal Hemorrhage/etiology , Gastrointestinal Hemorrhage/diagnosis , Intestine, Small/pathology , Intestine, Small/diagnostic imaging , Risk Assessment/methods
9.
World J Gastroenterol ; 30(10): 1270-1279, 2024 Mar 14.
Article En | MEDLINE | ID: mdl-38596501

In 2000, the small bowel capsule revolutionized the management of patients with small bowel disorders. Currently, the technological development achieved by the new models of double-headed endoscopic capsules, as miniaturized devices to evaluate the small bowel and colon [pan-intestinal capsule endoscopy (PCE)], makes this non-invasive procedure a disruptive concept for the management of patients with digestive disorders. This technology is expected to identify which patients will require conventional invasive endoscopic procedures (colonoscopy or balloon-assisted enteroscopy), based on the lesions detected by the capsule, i.e., those with an indication for biopsies or endoscopic treatment. The use of PCE in patients with inflammatory bowel diseases, namely Crohn's disease, as well as in patients with iron deficiency anaemia and/or overt gastrointestinal (GI) bleeding, after a non-diagnostic upper endoscopy (esophagogastroduodenoscopy), enables an effective, safe and comfortable way to identify patients with relevant lesions, who should undergo subsequent invasive endoscopic procedures. The recent development of magnetically controlled capsule endoscopy to evaluate the upper GI tract, is a further step towards the possibility of an entirely non-invasive assessment of all the segments of the digestive tract, from mouth-to-anus, meeting the expectations of the early developers of capsule endoscopy.


Capsule Endoscopy , Crohn Disease , Intestinal Diseases , Humans , Capsule Endoscopy/adverse effects , Capsule Endoscopy/methods , Endoscopy, Gastrointestinal/adverse effects , Endoscopy, Gastrointestinal/methods , Intestinal Diseases/pathology , Crohn Disease/diagnosis , Intestine, Small/diagnostic imaging , Intestine, Small/surgery , Intestine, Small/pathology , Gastrointestinal Hemorrhage/etiology , Gastrointestinal Hemorrhage/diagnosis
10.
Lancet Digit Health ; 6(5): e345-e353, 2024 May.
Article En | MEDLINE | ID: mdl-38670743

BACKGROUND: Capsule endoscopy reading is time consuming, and readers are required to maintain attention so as not to miss significant findings. Deep convolutional neural networks can recognise relevant findings, possibly exceeding human performances and reducing the reading time of capsule endoscopy. Our primary aim was to assess the non-inferiority of artificial intelligence (AI)-assisted reading versus standard reading for potentially small bowel bleeding lesions (high P2, moderate P1; Saurin classification) at per-patient analysis. The mean reading time in both reading modalities was evaluated among the secondary endpoints. METHODS: Patients aged 18 years or older with suspected small bowel bleeding (with anaemia with or without melena or haematochezia, and negative bidirectional endoscopy) were prospectively enrolled at 14 European centres. Patients underwent small bowel capsule endoscopy with the Navicam SB system (Ankon, China), which is provided with a deep neural network-based AI system (ProScan) for automatic detection of lesions. Initial reading was performed in standard reading mode. Second blinded reading was performed with AI assistance (the AI operated a first-automated reading, and only AI-selected images were assessed by human readers). The primary endpoint was to assess the non-inferiority of AI-assisted reading versus standard reading in the detection (diagnostic yield) of potentially small bowel bleeding P1 and P2 lesions in a per-patient analysis. This study is registered with ClinicalTrials.gov, NCT04821349. FINDINGS: From Feb 17, 2021 to Dec 29, 2021, 137 patients were prospectively enrolled. 133 patients were included in the final analysis (73 [55%] female, mean age 66·5 years [SD 14·4]; 112 [84%] completed capsule endoscopy). At per-patient analysis, the diagnostic yield of P1 and P2 lesions in AI-assisted reading (98 [73·7%] of 133 lesions) was non-inferior (p<0·0001) and superior (p=0·0213) to standard reading (82 [62·4%] of 133; 95% CI 3·6-19·0). Mean small bowel reading time was 33·7 min (SD 22·9) in standard reading and 3·8 min (3·3) in AI-assisted reading (p<0·0001). INTERPRETATION: AI-assisted reading might provide more accurate and faster detection of clinically relevant small bowel bleeding lesions than standard reading. FUNDING: ANKON Technologies, China and AnX Robotica, USA provided the NaviCam SB system.


Artificial Intelligence , Capsule Endoscopy , Gastrointestinal Hemorrhage , Intestine, Small , Humans , Capsule Endoscopy/methods , Gastrointestinal Hemorrhage/diagnosis , Prospective Studies , Female , Male , Middle Aged , Intestine, Small/diagnostic imaging , Intestine, Small/pathology , Aged , Adult , Aged, 80 and over , Neural Networks, Computer
11.
Am J Case Rep ; 25: e942838, 2024 Apr 08.
Article En | MEDLINE | ID: mdl-38584385

BACKGROUND Maldevelopment of the fetal bowel can result in the rare condition of intestinal atresia, which results in congenital bowel obstruction. This report describes a case of prenatal diagnosis of fetal ileal atresia at 22 weeks' gestation. CASE REPORT Here, we present a 24-year old woman who was 22 weeks into her first pregnancy when she underwent routine fetal ultrasound. She was diagnosed with gestational diabetes mellitus. Her body mass index was normal and she had normal weight gain. The ultrasonographic examination performed revealed a hyperechoic bowel and a small dilatation of the bowel. The couple was counselled for possible intestinal atresia and its postnatal implications. At 33 weeks of gestation, polyhydramnios appeared, and the intestinal distension was much more pronounced, with hyperechoic debris in the intestinal lumen (succus-entericus). After birth, surgery was performed and we concluded the patient had type II atresia, which was surgically treated. CONCLUSIONS This report has highlighted the importance of antenatal ultrasound in detecting fetal abnormalities, and has shown that rare conditions such as intestinal atresia can be accurately diagnosed and successfully managed. Surgical correction, if implemented promptly after stabilizing the general condition, can have a relatively good prognosis. Coexisting fetal ileal atresia and gestational diabetes mellitus are rare occurrences, which can make each condition even more difficult to treat.


Diabetes, Gestational , Intestinal Atresia , Intestine, Small/abnormalities , Humans , Female , Pregnancy , Young Adult , Adult , Diabetes, Gestational/diagnosis , Intestinal Atresia/diagnostic imaging , Intestinal Atresia/surgery , Intestine, Small/diagnostic imaging , Prenatal Diagnosis , Ultrasonography, Prenatal/methods
12.
Clin Res Hepatol Gastroenterol ; 48(5): 102334, 2024 May.
Article En | MEDLINE | ID: mdl-38582328

BACKGROUND: In order to overcome the challenges of lesion detection in capsule endoscopy (CE), we improved the YOLOv5-based deep learning algorithm and established the CE-YOLOv5 algorithm to identify small bowel lesions captured by CE. METHODS: A total of 124,678 typical abnormal images from 1,452 patients were enrolled to train the CE-YOLOv5 model. Then 298 patients with suspected small bowel lesions detected by CE were prospectively enrolled in the testing phase of the study. Small bowel images and videos from the above 298 patients were interpreted by the experts, non-experts and CE-YOLOv5, respectively. RESULTS: The sensitivity of CE-YOLOv5 in diagnosing vascular lesions, ulcerated/erosive lesions, protruding lesions, parasite, diverticulum, active bleeding and villous lesions based on CE videos was 91.9 %, 92.2 %, 91.4 %, 93.1 %, 93.3 %, 95.1 %, and 100 % respectively. Furthermore, CE-YOLOv5 achieved specificity and accuracy of more than 90 % for all lesions. Compared with experts, the CE-YOLOv5 showed comparable overall sensitivity, specificity and accuracy (all P > 0.05). Compared with non-experts, the CE-YOLOv5 showed significantly higher overall sensitivity (P < 0.0001) and overall accuracy (P < 0.0001), and a moderately higher overall specificity (P = 0.0351). Furthermore, the time for AI-reading (5.62 ± 2.81 min) was significantly shorter than that for the other two groups (both P < 0.0001). CONCLUSIONS: CE-YOLOv5 diagnosed small bowel lesions in CE videos with high sensitivity, specificity and accuracy, providing a reliable approach for automated lesion detection in real-world clinical practice.


Capsule Endoscopy , Deep Learning , Intestine, Small , Capsule Endoscopy/methods , Humans , Intestine, Small/diagnostic imaging , Intestine, Small/pathology , Female , Male , Middle Aged , Prospective Studies , Adult , Intestinal Diseases/diagnostic imaging , Intestinal Diseases/diagnosis , Aged , Sensitivity and Specificity , Algorithms
13.
J Neuroendocrinol ; 36(5): e13391, 2024 05.
Article En | MEDLINE | ID: mdl-38590270

Metastases outside the liver and abdominal/retroperitoneal lymph nodes are nowadays detected frequently in patients with neuroendocrine tumours (NETs), owing to the high sensitivity of positron emission tomography (PET) with Gallium-68-DOTA-somatostatin analogues (68Ga-SSA) and concomitant diagnostic computed tomography (CT). Our aim was to determine the prevalence of extra-abdominal metastases on 68Ga-DOTATOC-PET/CT in a cohort of patients with small intestinal (Si-NET) and pancreatic NET (Pan-NET), as well as that of pancreatic metastasis in patients with Si-NET. Among 2090 patients examined by 68Ga-DOTATOC-PET/CT at two tertiary referral centres, a total of 1177 patients with a history of Si- or Pan-NET, were identified. The most recent 68Ga-DOTATOC-PET/CT report for each patient was reviewed, and the location and number of metastases of interest were recorded. Lesions outside the liver and abdominal nodes were found in 26% of patients (n = 310/1177), of whom 21.5% (255/1177) were diagnosed with Si-NET and 4.5% (55/1177) Pan-NET. Bone metastases were found in 18.4% (215/1177), metastases to Virchow's lymph node in 7.1% (83/1177), and lung/pleura in 4.8% (56/1177). In the subset of 255 Si-NET patients, 5.4% (41/255) manifested lesions in the pancreas, 1.5% in the breast (18/255), 1.3% in the heart (15/255) and 1% in the orbita (12/255). In Si-NET patients, the Ki-67 proliferation index was higher in those with ≥2 metastatic sites of interest, than with 1 metastatic site, (p <0.001). Overall, extra-abdominal or pancreatic metastases were more often found in patients with Si-NET (34%) than in those with Pan-NET (13%) (p <0.001). Bone metastases were 2.6 times more frequent in patients with Si-NET compared to Pan-NET patients (p <0.001). Lesions to the breast and orbita were encountered in almost only Si-NET patients. In conclusion, lesions outside the liver and abdominal nodes were detected in as many as 26% of the patients, with different prevalence and metastatic patterns in patients with Si-NET compared to Pan-NET. The impact of such metastases on overall survival and clinical decision-making needs further evaluation.


Intestinal Neoplasms , Lymphatic Metastasis , Neuroendocrine Tumors , Octreotide , Organometallic Compounds , Pancreatic Neoplasms , Positron Emission Tomography Computed Tomography , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Intestinal Neoplasms/epidemiology , Intestinal Neoplasms/pathology , Intestinal Neoplasms/diagnostic imaging , Intestine, Small/diagnostic imaging , Intestine, Small/pathology , Lymph Nodes/pathology , Lymph Nodes/diagnostic imaging , Lymphatic Metastasis/diagnostic imaging , Lymphatic Metastasis/pathology , Neuroendocrine Tumors/pathology , Neuroendocrine Tumors/epidemiology , Neuroendocrine Tumors/diagnostic imaging , Octreotide/analogs & derivatives , Pancreatic Neoplasms/pathology , Pancreatic Neoplasms/epidemiology , Pancreatic Neoplasms/diagnostic imaging , Prevalence , Retrospective Studies
14.
Radiographics ; 44(4): e230122, 2024 Apr.
Article En | MEDLINE | ID: mdl-38483832

Celiac disease is a common inflammatory disease of the small bowel that induces mucosal intestinal lesions. The disease is mediated by an immune response and triggered by the ingestion of gluten in genetically predisposed individuals. Gluten contains gliadin, a component found mostly in wheat, barley, and rye. This process leads to gastrointestinal malabsorption with symptoms such as diarrhea, constipation, abdominal pain, and distention. It has a prevalence of 1%-2% in the general adult population, who present with symptoms at any age, but is more frequently found in adult women in the 3rd or 4th decade of life. Recognition of the disease has increased, but it remains a challenge to diagnose. CT and MR enterography are noninvasive studies used for evaluation of small bowel neoplasms and inflammatory small bowel pathologic conditions such as celiac disease. The authors review the spectrum of intestinal and extraintestinal findings of celiac disease at CT and MR enterography, as well as its complications, and the importance of recognizing certain imaging features that help in the diagnosis of celiac disease. More common and specific findings of celiac disease such as inversion of the jejunoileal fold pattern and mesenteric lymphadenopathy are reviewed. More uncommon entities that are more frequently associated with refractory or untreated celiac disease, such as ulcerative jejunoileitis, cavitary mesenteric lymph node syndrome, and malignancies including small bowel adenocarcinoma and lymphoma, are described. ©RSNA, 2024 Test Your Knowledge questions for this article are available in the supplemental material. The slide presentation from the RSNA Annual Meeting is available for this article.


Celiac Disease , Adult , Female , Humans , Celiac Disease/diagnostic imaging , Celiac Disease/complications , Diagnosis, Differential , Glutens , Intestine, Small/diagnostic imaging , Tomography, X-Ray Computed , Male
15.
Vet Radiol Ultrasound ; 65(3): 264-274, 2024 May.
Article En | MEDLINE | ID: mdl-38436052

Small intestinal obstruction in rabbits, although demonstrated to be common, is still poorly characterized. The objective of this study was to report features of small intestinal obstruction caused by trichobezoars in rabbits upon CT and their clinical outcomes. Rabbits with a diagnosis of intestinal obstruction that underwent CT scanning were included in this study. From each CT scan, obstruction location, appearance, Hounsfield units, size (mm), volume (mm3), distance from the stomach, and diameter of the small intestine proximal and distal to it, were extracted. Nine rabbits were included in the study. All rabbits presented for anorexia and had a distended or enlarged stomach (7) or abdomen (2). CT scan showed a non-contrast-enhancing, ovoid, smoothly marginated structure with a hyperattenuating rim, heterogeneous center, and variable amount of centrally located gas, in the duodenum (5), the jejunum (2), or the ileum (2). The density of the trichobezoars ranged from -156 to 58 HU (median, -44 HU) and volume ranged from 86.1 to 633.8 mm3 (median, 320.6 mm3). Three rabbits underwent medical management. Two of them survived, and one of them died. Six rabbits underwent surgery, of which three were successfully discharged from the hospital. CT proved to be a valuable imaging modality in rabbits with a suspected intestinal obstruction to provide the exact location of the obstruction and the characteristics of the obstructive material. The location and size of the trichobezoar may have relevant clinical implications.


Bezoars , Intestinal Obstruction , Intestine, Small , Tomography, X-Ray Computed , Animals , Rabbits , Intestinal Obstruction/veterinary , Intestinal Obstruction/diagnostic imaging , Intestinal Obstruction/etiology , Intestinal Obstruction/surgery , Bezoars/veterinary , Bezoars/diagnostic imaging , Bezoars/complications , Tomography, X-Ray Computed/veterinary , Female , Intestine, Small/diagnostic imaging , Male
17.
Scand J Gastroenterol ; 59(6): 683-689, 2024 Jun.
Article En | MEDLINE | ID: mdl-38501494

BACKGROUND: Imaging is used to monitor disease activity in small bowel Crohn's disease (CD). Magnetic Resonance Enterography is often employed as a first modality in the United Kingdom for assessment and monitoring; however, waiting times, cost, patient burden and limited access are significant. It is as yet uncertain if small bowel intestinal ultrasound (IUS) may be a quicker, more acceptable, and cheaper alternative for monitoring patients with CD. METHODS: A clinical service evaluation of imaging pathways was undertaken at a single NHS site in England, United Kingdom. Data were collected about patients who were referred and underwent an imaging analysis for their IBD. Only patients who underwent a therapy change were included in the analysis. Data were collected from care episodes between 01 January 2021-30 March 2022. RESULTS: A combined total of 193 patient care episodes were reviewed, 107 from the IUS pathway and 86 from the MRE pathway. Estimated costs per patient in the IUS pathway was £78.86, and £375.35 per patient in the MRE pathway. The MRE pathway had an average time from referral to treatment initiation of 91 days (SD= ±61) with patients in the IUS pathway waiting an average of 46 days (SD= ±17). CONCLUSIONS: Findings from this work indicate that IUS is a potential cost-saving option when compared to MRE when used in the management of CD. This is in addition to the cost difference of the radiological modalities. A large, multicentre, prospective study is needed to validate these initial findings.


What is already known on this topic ­ Ultrasound is a quick and accurate imaging investigation for patients living with Crohn's disease. Its effect on the cost utility of an Inflammatory Bowel Disease service is unknown.What this study adds ­ This work provides initial data suggesting that an ultrasound-based service may provide significant cost savings when compared to a magnetic resonance imaging-based service.How this study might affect research, practice, or policy ­ This work is part of a larger programme of work to investigate the barriers to wider ultrasound implementation in UK IBD services. This work will contribute to the design of an implementation and training package for intestinal ultrasound in the UK.


Cost Savings , Crohn Disease , Magnetic Resonance Imaging , Ultrasonography , Humans , Magnetic Resonance Imaging/economics , Ultrasonography/economics , Crohn Disease/diagnostic imaging , Crohn Disease/therapy , Crohn Disease/economics , Male , Female , Inflammatory Bowel Diseases/diagnostic imaging , Inflammatory Bowel Diseases/therapy , Inflammatory Bowel Diseases/economics , Adult , Cost-Benefit Analysis , Intestine, Small/diagnostic imaging , England , United Kingdom , Middle Aged
18.
Emerg Radiol ; 31(2): 193-201, 2024 Apr.
Article En | MEDLINE | ID: mdl-38374481

PURPOSE: Blunt bowel and/or mesenteric injury requiring surgery presents a diagnostic challenge. Although computed tomography (CT) imaging is standard following blunt trauma, findings can be nonspecific. Most studies have focused on the diagnostic value of CT findings in identifying significant bowel and/or mesenteric injury (sBMI). Some studies have described scoring systems to assist with diagnosis. Little attention, has been given to radiologist interpretation of CT scans. This study compared the discriminative ability of scoring systems (BIPS and RAPTOR) with radiologist interpretation in identifying sBMI. METHODS: We conducted a retrospective chart review of trauma patients with suspected sBMI. CT images were reviewed in a blinded fashion to calculate BIPS and RAPTOR scores. Sensitivity and specificity were compared between BIPS, RAPTOR, and the admission CT report with respect to identifying sBMI. RESULTS: One hundred sixty-two patients were identified, 72 (44%) underwent laparotomy and 43 (26.5%) had sBMI. Sensitivity and specificity were: BIPS 49% and 87%, AUC 0.75 (0.67-0.81), P < 0.001; RAPTOR 46% and 82%, AUC 0.72 (0.64-0.79), P < 0.001; radiologist impression 81% and 71%, AUC 0.82(0.75-0.87), P < 0.001. The discriminative ability of the radiologist impression was higher than RAPTOR (P = 0.04) but not BIPS (P = 0.13). There was not a difference between RAPTOR vs. BIPS (P = 0.55). CONCLUSION: Radiologist interpretation of the admission CT scan was discriminative of sBMI. Although surgical vigilance, including evaluation of the CT images and patient, remains fundamental to early diagnosis, the radiologist's impression of the CT scan can be used in clinical practice to simplify the approach to patients with abdominal trauma.


Abdominal Injuries , Wounds, Nonpenetrating , Humans , Retrospective Studies , Intestine, Small/diagnostic imaging , Intestine, Small/injuries , Intestines/injuries , Tomography, X-Ray Computed/methods , Abdominal Injuries/diagnostic imaging , Abdominal Injuries/surgery , Wounds, Nonpenetrating/diagnostic imaging , Wounds, Nonpenetrating/surgery
19.
BMC Gastroenterol ; 24(1): 80, 2024 Feb 22.
Article En | MEDLINE | ID: mdl-38388860

OBJECTIVES: Poorly visualized images that appear during small bowel capsule endoscopy (SBCE) can confuse the interpretation of small bowel lesions and increase the physician's workload. Using a validated artificial intelligence (AI) algorithm that can evaluate the mucosal visualization, we aimed to assess whether SBCE reading after the removal of poorly visualized images could affect the diagnosis of SBCE. METHODS: A study was conducted to analyze 90 SBCE cases in which a small bowel examination was completed. Two experienced endoscopists alternately performed two types of readings. They used the AI algorithm to remove poorly visualized images for the frame reduction reading (AI user group) and conducted whole frame reading without AI (AI non-user group) for the same patient. A poorly visualized image was defined as an image with < 50% mucosal visualization. The study outcomes were diagnostic concordance and reading time between the two groups. The SBCE diagnosis was classified as Crohn's disease, bleeding, polyp, angiodysplasia, and nonspecific finding. RESULTS: The final SBCE diagnoses between the two groups showed statistically significant diagnostic concordance (k = 0.954, p < 0.001). The mean number of lesion images was 3008.5 ± 9964.9 in the AI non-user group and 1401.7 ± 4811.3 in the AI user group. There were no cases in which lesions were completely removed. Compared with the AI non-user group (120.9 min), the reading time was reduced by 35.6% in the AI user group (77.9 min). CONCLUSIONS: SBCE reading after reducing poorly visualized frames using the AI algorithm did not have a negative effect on the final diagnosis. SBCE reading method integrated with frame reduction and mucosal visualization evaluation will help improve AI-assisted SBCE interpretation.


Capsule Endoscopy , Colonic Diseases , Crohn Disease , Humans , Artificial Intelligence , Intestine, Small/diagnostic imaging , Intestine, Small/pathology , Crohn Disease/diagnostic imaging , Crohn Disease/surgery , Retrospective Studies
20.
Eur J Radiol ; 173: 111363, 2024 Apr.
Article En | MEDLINE | ID: mdl-38367415

PURPOSE: To assess diagnostic performance and reproducibility of reduced bowel wall enhancement evaluated by quantitative methods using CT to identify bowel necrosis among closed-loop small bowel obstruction (CL-SBO) patients. METHODS: This retrospective single-center study included patients who diagnosed with CL-SBO caused by adhesion or internal hernia during January 2016 and May 2022. Patients were divided into necrotic group (n = 41) and non-necrotic group (n = 67) according to surgical exploration and postoperative pathology. Two doctors independently measured the attenuation of bowel wall and consensus was reached through panel discussion with a third gastrointestinal radiologist. Reduced bowel wall enhancement was assessed by four quantitative methods. Univariate analyses were used to evaluate the association between each method and bowel necrosis, and kappa/intraclass correlation coefficient values were used to assess interobserver agreement. Diagnostic performance parameters were calculated for each method. RESULTS: Reduced bowel wall enhancement in arterial phase (OR 8.98, P < 0.0001), reduced bowel wall enhancement in portal phase (OR 16.84, P < 0.001), adjusted reduced bowel wall enhancement in arterial phase (OR 29.48, P < 0.001), adjusted reduced bowel wall enhancement in portal phase (OR 145.69, P < 0.001) were significantly associated with bowel necrosis. Adjusted reduced bowel wall enhancement in portal phase had the best diagnostic performance (AUC: 0.92; Youden index: 0.84; specificity: 94.03 %) and interobserver agreement (kappa value of 0.59-0.73) to predict bowel necrosis. CONCLUSION: When assessing reduced bowel enhancement to predict bowel necrosis among CL-SBO patients, using unenhanced CT images and proximal dilated loop as standard references in portal phase is the most accurate quantitative method among those tested.


Abdominal Injuries , Intestinal Obstruction , Vascular Diseases , Humans , Tomography, X-Ray Computed/methods , Retrospective Studies , Reproducibility of Results , Intestine, Small/diagnostic imaging , Sensitivity and Specificity , Intestinal Obstruction/diagnostic imaging , Intestinal Obstruction/surgery , Vascular Diseases/pathology , Necrosis/diagnostic imaging , Necrosis/pathology , Abdominal Injuries/complications
...