Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 994
Filter
1.
Anal Chem ; 96(25): 10170-10181, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38862388

ABSTRACT

The diversity of cannabinoid isomers and complexity of Cannabis products pose significant challenges for analytical methodologies. In this study, we developed a method to analyze 14 different cannabinoid isomers in diverse samples within milliseconds by leveraging the unique adduct-forming behavior of silver ions in advanced cyclic ion mobility spectrometry-mass spectrometry. The developed method achieved the separation of isomers from four groups of cannabinoids: Δ3-tetrahydrocannabinol (THC) (1), Δ8-THC (2), Δ9-THC (3), cannabidiol (CBD) (4), Δ8-iso-THC (5), and Δ(4)8-iso-THC (6) (all MW = 314); 9α-hydroxyhexahydrocannabinol (7), 9ß-hydroxyhexahydrocannabinol (8), and 8-hydroxy-iso-THC (9) (all MW = 332); tetrahydrocannabinolic acid (THCA) (10) and cannabidiolic acid (CBDA) (11) (both MW = 358); Δ8-tetrahydrocannabivarin (THCV) (12), Δ8-iso-THCV (13), and Δ9-THCV (14) (all MW = 286). Moreover, experimental and theoretical traveling wave collision cross section values in nitrogen (TWCCSN2) of cannabinoid-Ag(I) species were obtained for the first time with an average error between experimental and theoretical values of 2.6%. Furthermore, a workflow for the identification of cannabinoid isomers in Cannabis and Cannabis-derived samples was established based on three identification steps (m/z and isotope pattern of Ag(I) adducts, TWCCSN2, and MS/MS fragments). Afterward, calibration curves of three major cannabinoids were established with a linear range of 1-250 ng·ml-1 for Δ8-THC (2) (R2 = 0.9999), 0.1-25 ng·ml-1 for Δ9-THC (3) (R2 = 0.9987), and 0.04-10 ng·ml-1 for CBD (4) (R2 = 0.9986) as well as very low limits of detection (0.008-0.2 ng·ml-1). Finally, relative quantification of Δ8-THC (2), Δ9-THC (3), and CBD (4) in eight complex acid-treated CBD mixtures was achieved without chromatographic separation. The results showed good correspondence (R2 = 0.999) with those obtained by gas chromatography-flame ionization detection/mass spectrometry.


Subject(s)
Cannabinoids , Cannabis , Dronabinol , Ion Mobility Spectrometry , Mass Spectrometry , Cannabis/chemistry , Cannabinoids/analysis , Cannabinoids/chemistry , Dronabinol/analysis , Dronabinol/analogs & derivatives , Ion Mobility Spectrometry/methods , Mass Spectrometry/methods , Plant Extracts/chemistry , Plant Extracts/analysis , Isomerism
2.
Anal Methods ; 16(25): 4041-4044, 2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38869241

ABSTRACT

Xylazine represents an increased threat to the recreational drug market. In this study, we present a rapid strategy for identifying xylazine and differentiating its common isomeric metabolites using Structures for Lossless Ion Manipulations (SLIM) ion mobility coupled to high-resolution/tandem mass spectrometry (IM-HRMS/MS). Chemical derivatization using dansyl chloride also assisted with separations and led to identification of resolvable reaction product atropisomers.


Subject(s)
Tandem Mass Spectrometry , Xylazine , Tandem Mass Spectrometry/methods , Ion Mobility Spectrometry/methods , Dansyl Compounds/chemistry , Humans , Isomerism
3.
Anal Chem ; 96(24): 10003-10012, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38853531

ABSTRACT

Fc-fusion proteins are an emerging class of protein therapeutics that combine the properties of biological ligands with the unique properties of the fragment crystallizable (Fc) domain of an immunoglobulin G (IgG). Due to their diverse higher-order structures (HOSs), Fc-fusion proteins remain challenging characterization targets within biopharmaceutical pipelines. While high-resolution biophysical tools are available for HOS characterization, they frequently demand extended time frames and substantial quantities of purified samples, rendering them impractical for swiftly screening candidate molecules. Herein, we describe the development of ion mobility-mass spectrometry (IM-MS) and collision-induced unfolding (CIU) workflows that aim to fill this technology gap, where we focus on probing the HOS of a model Fc-Interleukin-10 (Fc-IL-10) fusion protein engineered using flexible glycine-serine linkers. We evaluate the ability of these techniques to probe the flexibility of Fc-IL-10 in the absence of bulk solvent relative to other proteins of similar size, as well as localize structural changes of low charge state Fc-IL-10 ions to specific Fc and IL-10 unfolding events during CIU. We subsequently apply these tools to probe the local effects of glycine-serine linkers on the HOS and stability of IL-10 homodimer, which is the biologically active form of IL-10. Our data reveals that Fc-IL-10 produces significantly more structural transitions during CIU and broader IM profiles when compared to a wide range of model proteins, indicative of its exceptional structural dynamism. Furthermore, we use a combination of enzymatic approaches to annotate these intricate CIU data and localize specific transitions to the unfolding of domains within Fc-IL-10. Finally, we detect a strong positive, quadratic relationship between average linker mass and fusion protein stability, suggesting a cooperative influence between glycine-serine linkers and overall fusion protein stability. This is the first reported study on the use of IM-MS and CIU to characterize HOS of Fc-fusion proteins, illustrating the practical applicability of this approach.


Subject(s)
Immunoglobulin Fc Fragments , Mass Spectrometry , Protein Unfolding , Recombinant Fusion Proteins , Immunoglobulin Fc Fragments/chemistry , Recombinant Fusion Proteins/chemistry , Mass Spectrometry/methods , Interleukin-10/chemistry , Interleukin-10/metabolism , Ion Mobility Spectrometry/methods , Protein Stability , Humans , Immunoglobulin G/chemistry
4.
Cell Rep Methods ; 4(6): 100795, 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38861989

ABSTRACT

The polyclonal repertoire of circulating antibodies potentially holds valuable information about an individual's humoral immune state. While bottom-up proteomics is well suited for serum proteomics, the vast number of antibodies and dynamic range of serum challenge this analysis. To acquire the serum proteome more comprehensively, we incorporated high-field asymmetric waveform ion-mobility spectrometry (FAIMS) or two-dimensional chromatography into standard trypsin-based bottom-up proteomics. Thereby, the number of variable region (VR)-related spectra increased 1.7-fold with FAIMS and 10-fold with chromatography fractionation. To match antibody VRs to spectra, we combined de novo searching and BLAST alignment. Validation of this approach showed that, as peptide length increased, the de novo accuracy decreased and BLAST performance increased. Through in silico calculations on antibody repository sequences, we determined the uniqueness of tryptic VR peptides and their suitability as antibody surrogate. Approximately one-third of these peptides were unique, and about one-third of all antibodies contained at least one unique peptide.


Subject(s)
Peptides , Trypsin , Humans , Trypsin/chemistry , Trypsin/metabolism , Peptides/immunology , Peptides/chemistry , Immunoglobulin Variable Region/chemistry , Immunoglobulin Variable Region/immunology , Proteomics/methods , Ion Mobility Spectrometry/methods
5.
J Med Chem ; 67(12): 10436-10446, 2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38783480

ABSTRACT

Ion mobility mass spectrometry (IM-MS) can be used to analyze native proteins according to their size and shape. By sampling individual molecules, it allows us to study mixtures of conformations, as long as they have different collision cross sections and maintain their native conformation after dehydration and vaporization in the mass spectrometer. Even though conformational heterogeneity of prolyl oligopeptidase has been demonstrated in solution, it is not detectable in IM-MS. Factors that affect the conformation in solution, binding of an active site ligand, the stabilizing Ser554Ala mutation, and acidification do not qualitatively affect the collision-induced unfolding pattern. However, measuring the protection of accessible cysteines upon ligand binding provides a principle for the development of MS-based ligand screening methods.


Subject(s)
Prolyl Oligopeptidases , Protein Conformation , Serine Endopeptidases , Prolyl Oligopeptidases/metabolism , Serine Endopeptidases/chemistry , Serine Endopeptidases/metabolism , Ligands , Ion Mobility Spectrometry , Models, Molecular , Mass Spectrometry/methods , Catalytic Domain , Humans
6.
J Lipid Res ; 65(6): 100567, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38795862

ABSTRACT

Lipids play pivotal roles in an extensive range of metabolic and physiological processes. In recent years, the convergence of trapped ion mobility spectrometry and MS has enabled 4D-lipidomics, a highly promising technology for comprehensive lipid analysis. 4D-lipidomics assesses lipid annotations across four distinct dimensions-retention time, collisional cross section, m/z (mass-to-charge ratio), and MS/MS spectra-providing a heightened level of confidence in lipid annotation. These advantages prove particularly valuable when investigating complex disorders involving lipid metabolism, such as adrenoleukodystrophy (ALD). ALD is characterized by the accumulation of very-long-chain fatty acids (VLCFAs) due to pathogenic variants in the ABCD1 gene. A comprehensive 4D-lipidomics strategy of ALD fibroblasts demonstrated significant elevations of various lipids from multiple classes. This indicates that the changes observed in ALD are not confined to a single lipid class and likely impacts a broad spectrum of lipid-mediated physiological processes. Our findings highlight the incorporation of mainly saturated and monounsaturated VLCFA variants into a range of lipid classes, encompassing phosphatidylcholines, triacylglycerols, and cholesterol esters. These include ultra-long-chain fatty acids with a length of up to thirty carbon atoms. Lipid species containing C26:0 and C26:1 were the most frequently detected VLCFA lipids in our study. Furthermore, we report a panel of 121 new candidate biomarkers in fibroblasts, exhibiting significant differentiation between controls and individuals with ALD. In summary, this study demonstrates the capabilities of a 4D-lipid profiling workflow in unraveling novel insights into the intricate lipid modifications associated with metabolic disorders like ALD.


Subject(s)
Adrenoleukodystrophy , Ion Mobility Spectrometry , Lipidomics , Adrenoleukodystrophy/metabolism , Adrenoleukodystrophy/genetics , Humans , Lipidomics/methods , Lipids/analysis , Lipid Metabolism
7.
J Proteome Res ; 23(6): 1871-1882, 2024 Jun 07.
Article in English | MEDLINE | ID: mdl-38713528

ABSTRACT

The coevolution of liquid chromatography (LC) with mass spectrometry (MS) has shaped contemporary proteomics. LC hyphenated to MS now enables quantification of more than 10,000 proteins in a single injection, a number that likely represents most proteins in specific human cells or tissues. Separations by ion mobility spectrometry (IMS) have recently emerged to complement LC and further improve the depth of proteomics. Given the theoretical advantages in speed and robustness of IMS in comparison to LC, we envision that ongoing improvements to IMS paired with MS may eventually make LC obsolete, especially when combined with targeted or simplified analyses, such as rapid clinical proteomics analysis of defined biomarker panels. In this perspective, we describe the need for faster analysis that might drive this transition, the current state of direct infusion proteomics, and discuss some technical challenges that must be overcome to fully complete the transition to entirely gas phase proteomics.


Subject(s)
Ion Mobility Spectrometry , Proteomics , Proteomics/methods , Ion Mobility Spectrometry/methods , Humans , Chromatography, Liquid/methods , Mass Spectrometry/methods , High-Throughput Screening Assays/methods
8.
J Am Chem Soc ; 146(21): 14468-14478, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38757172

ABSTRACT

Many biological mechanisms rely on the precise control of conformational changes in proteins. Understanding such dynamic processes requires methods for determining structures and their temporal evolution. In this study, we introduce a novel approach to time-resolved ion mobility mass spectrometry. We validated the method on a simple photoreceptor model and applied it to a more complex system, the animal-like cryptochrome from Chlamydomonas reinhardtii (CraCRY), to determine the role of specific amino acids affecting the conformational dynamics as reaction to blue light activation. In our setup, using a high-power LED mounted in the source region of an ion mobility mass spectrometer, we allow a time-resolved evaluation of mass and ion mobility spectra. Cryptochromes like CraCRY are a widespread type of blue light photoreceptors and mediate various light-triggered biological functions upon excitation of their inbuilt flavin chromophore. Another hallmark of cryptochromes is their flexible carboxy-terminal extension (CTE), whose structure and function as well as the details of its interaction with the photolyase homology region are not yet fully understood and differ among different cryptochromes types. Here, we addressed the highly conserved C-terminal domain of CraCRY, to study the effects of single mutations on the structural transition of the C-terminal helix α22 and the attached CTE upon lit-state formation. We show that D321, the putative proton acceptor of the terminal proton-coupled electron transfer event from Y373, is essential for triggering the large-scale conformational changes of helix α22 and the CTE in the lit state, while D323 influences the timing.


Subject(s)
Chlamydomonas reinhardtii , Cryptochromes , Protein Conformation , Cryptochromes/chemistry , Cryptochromes/metabolism , Chlamydomonas reinhardtii/chemistry , Chlamydomonas reinhardtii/metabolism , Mass Spectrometry/methods , Ion Mobility Spectrometry/methods , Models, Molecular
9.
Anal Chem ; 96(23): 9390-9398, 2024 Jun 11.
Article in English | MEDLINE | ID: mdl-38812282

ABSTRACT

Ion mobility mass spectrometry (IM-MS) measures the mass, size, and shape of ions in the same experiment, and structural information is provided via collision cross-section (CCS) values. The majority of commercially available IM-MS instrumentation relies on the use of CCS calibrants, and here, we present data from a family of poly(l-lysine) dendrimers and explore their suitability for this purpose. In order to test these compounds, we employed three different IM-MS platforms (Agilent 6560 IM-QToF, Waters Synapt G2, and a home-built variable temperature drift tube IM-MS) and used them to investigate six different generations of dendrimers in two buffer gases (helium and nitrogen). Each molecule gives a highly discrete CCS distribution suggestive of single conformers for each m/z value. The DTCCSN2 values of this series of molecules (molecular weight: 330-16,214 Da) range from 182 to 2941 Å2, which spans the CCS range that would be found by many synthetic molecules including supramolecular compounds and many biopolymers. The CCS values for each charge state were highly reproducible in day-to-day analysis on each instrument, although we found small variations in the absolute CCS values between instruments. The rigidity of each dendrimer was probed using collisionally activated and high-temperature IM-MS experiments, where no evidence for a significant CCS change ensued. Taken together, this data indicates that these polymers are candidates for CCS calibration and could also help to reconcile differences found in CCS measurements on different instrument geometries.


Subject(s)
Dendrimers , Ion Mobility Spectrometry , Polylysine , Dendrimers/chemistry , Polylysine/chemistry , Ion Mobility Spectrometry/methods , Mass Spectrometry/methods , Molecular Conformation
10.
J Breath Res ; 18(3)2024 05 17.
Article in English | MEDLINE | ID: mdl-38701772

ABSTRACT

The analysis of volatile organic compounds (VOCs) in exhaled air has attracted the interest of the scientific community because it provides the possibility of monitoring physiological and metabolic processes and non-invasive diagnostics of various diseases. However, this method remains underused in clinical practice as well as in research because of the lack of standardized procedures for the collection, storage and transport of breath samples, which would guarantee good reproducibility and comparability of results. The method of sampling, as well as the storage time of the breath samples in the polymer bags used for sample storage and transport, affect the composition and concentration of VOCs present in the breath samples. The aim of our study was to compare breath samples obtained using two methods with fully disposable equipment: a Haldane sampling tube intended for direct breath collection and breath samples exhaled into a transparent Tedlar bag. The second task was to monitor the stability of selected compounds of real breath samples stored in a Tedlar bag for 6 h. Gas chromatography coupled with ion mobility spectrometry (GC-IMS) implemented in the BreathSpec®device was used to analyse exhaled breath. Our results showed a significant difference in the signal intensity of some volatiles when taking a breath sample with a Haldane tube and a Tedlar bag. Due to its endogenous origin, acetone levels were significantly higher when the Haldane tube sampler was used while elevated levels of 2-propanol and unidentified VOC (designated as VOC 3) in the Tedlar bag samples likely originated from contamination of the Tedlar bags. The VOC stability study revealed compound-specific signal intensity changes of the selected VOCs with storage time in the Tedlar bags, with some volatiles showing increasing signal intensity during storage in Tedlar bags. This limits the use of Tedlar bags only for very limited time and carefully selected purpose. Our results highlight the importance of careful design and implementation of experiments and clinical protocols to obtain relevant and reliable results.


Subject(s)
Breath Tests , Specimen Handling , Volatile Organic Compounds , Humans , Breath Tests/instrumentation , Breath Tests/methods , Volatile Organic Compounds/analysis , Specimen Handling/instrumentation , Specimen Handling/methods , Ion Mobility Spectrometry/methods , Ion Mobility Spectrometry/instrumentation , Male , Female , Reproducibility of Results , Adult , Gas Chromatography-Mass Spectrometry/methods , Gas Chromatography-Mass Spectrometry/instrumentation , Exhalation , Middle Aged , Time Factors
11.
J Chromatogr A ; 1725: 464931, 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38703457

ABSTRACT

Atractylodis rhizoma is a common bulk medicinal material with multiple species. Although different varieties of atractylodis rhizoma exhibit variations in their chemical constituents and pharmacological activities, they have not been adequately distinguished due to their similar morphological features. Hence, the purpose of this research is to analyze and characterize the volatile organic compounds (VOCs) in samples of atractylodis rhizoma using multiple techniques and to identify the key differential VOCs among different varieties of atractylodis rhizoma for effective discrimination. The identification of VOCs was carried out using headspace solid-phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS) and headspace gas chromatography-ion mobility spectrometry (HS-GC-IMS), resulting in the identification of 60 and 53 VOCs, respectively. The orthogonal partial least squares discriminant analysis (OPLS-DA) model was employed to screen potential biomarkers and based on the variable importance in projection (VIP ≥ 1.2), 24 VOCs were identified as critical differential compounds. Random forest (RF), K-nearest neighbor (KNN) and back propagation neural network based on genetic algorithm (GA-BPNN) models based on potential volatile markers realized the greater than 90 % discriminant accuracies, which indicates that the obtained key differential VOCs are reliable. At the same time, the aroma characteristics of atractylodis rhizoma were also analyzed by ultra-fast gas chromatography electronic nose (Ultra-fast GC E-nose). This study indicated that the integration of HS-SPME-GC-MS, HS-GC-IMS and ultra-fast GC E-nose with chemometrics can comprehensively reflect the differences of VOCs in atractylodis rhizoma samples from different varieties, which will be a prospective tool for variety discrimination of atractylodis rhizoma.


Subject(s)
Atractylodes , Electronic Nose , Gas Chromatography-Mass Spectrometry , Solid Phase Microextraction , Volatile Organic Compounds , Volatile Organic Compounds/analysis , Gas Chromatography-Mass Spectrometry/methods , Solid Phase Microextraction/methods , Atractylodes/chemistry , Ion Mobility Spectrometry/methods , Rhizome/chemistry , Discriminant Analysis
12.
J Mass Spectrom ; 59(6): e5039, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38747242

ABSTRACT

Utilizing a data-driven approach, this study investigates modifier effects on compensation voltage in differential mobility spectrometry-mass spectrometry (DMS-MS) for metabolites and peptides. Our analysis uncovers specific factors causing signal suppression in small molecules and pinpoints both signal suppression mechanisms and the analytes involved. In peptides, machine learning models discern a relationship between molecular weight, topological polar surface area, peptide charge, and proton transfer-induced signal suppression. The models exhibit robust performance, offering valuable insights for the application of DMS to metabolites and tryptic peptides analysis by DMS-MS.


Subject(s)
Ion Mobility Spectrometry , Metabolomics , Peptides , Metabolomics/methods , Peptides/chemistry , Peptides/analysis , Ion Mobility Spectrometry/methods , Mass Spectrometry/methods , Machine Learning , Proteomics/methods , Molecular Weight
13.
Sensors (Basel) ; 24(9)2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38732837

ABSTRACT

The gut microbiota and its related metabolites differ between inflammatory bowel disease (IBD) patients and healthy controls. In this study, we compared faecal volatile organic compound (VOC) patterns of paediatric IBD patients and controls with gastrointestinal symptoms (CGIs). Additionally, we aimed to assess if baseline VOC profiles could predict treatment response in paediatric IBD patients. We collected faecal samples from a cohort of de novo therapy-naïve paediatric IBD patients and CGIs. VOCs were analysed using gas chromatography-ion mobility spectrometry (GC-IMS). Response was defined as a combination of clinical response based on disease activity scores, without requiring treatment escalation. We included 109 paediatric IBD patients and 75 CGIs, aged 4 to 17 years. Faecal VOC profiles of paediatric IBD patients were distinguishable from those of CGIs (AUC ± 95% CI, p-values: 0.71 (0.64-0.79), <0.001). This discrimination was observed in both Crohn's disease (CD) (0.75 (0.67-0.84), <0.001) and ulcerative colitis (UC) (0.67 (0.56-0.78), 0.01) patients. VOC profiles between CD and UC patients were not distinguishable (0.57 (0.45-0.69), 0.87). Baseline VOC profiles of responders did not differ from non-responders (0.70 (0.58-0.83), 0.1). In conclusion, faecal VOC profiles of paediatric IBD patients differ significantly from those of CGIs.


Subject(s)
Feces , Inflammatory Bowel Diseases , Ion Mobility Spectrometry , Volatile Organic Compounds , Humans , Volatile Organic Compounds/analysis , Child , Feces/chemistry , Adolescent , Female , Male , Case-Control Studies , Child, Preschool , Ion Mobility Spectrometry/methods , Inflammatory Bowel Diseases/metabolism , Crohn Disease/metabolism , Colitis, Ulcerative/metabolism , Gas Chromatography-Mass Spectrometry/methods , Gastrointestinal Microbiome/physiology
14.
Protein Sci ; 33(6): e5008, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38723181

ABSTRACT

One of the most important attributes of anti-amyloid antibodies is their selective binding to oligomeric and amyloid aggregates. However, current methods of examining the binding specificities of anti-amyloid ß (Aß) antibodies have limited ability to differentiate between complexes that form between antibodies and monomeric or oligomeric Aß species during the dynamic Aß aggregation process. Here, we present a high-resolution native ion-mobility mass spectrometry (nIM-MS) method to investigate complexes formed between a variety of Aß oligomers and three Aß-specific IgGs, namely two antibodies with relatively high conformational specificity (aducanumab and A34) and one antibody with low conformational specificity (crenezumab). We found that crenezumab primarily binds Aß monomers, while aducanumab preferentially binds Aß monomers and dimers and A34 preferentially binds Aß dimers, trimers, and tetrameters. Through collision induced unfolding (CIU) analysis, our data indicate that antibody stability is increased upon Aß binding and, surprisingly, this stabilization involves the Fc region. Together, we conclude that nIM-MS and CIU enable the identification of Aß antibody binding stoichiometries and provide important details regarding antibody binding mechanisms.


Subject(s)
Amyloid beta-Peptides , Antibodies, Monoclonal, Humanized , Ion Mobility Spectrometry , Amyloid beta-Peptides/chemistry , Amyloid beta-Peptides/immunology , Amyloid beta-Peptides/metabolism , Antibodies, Monoclonal, Humanized/chemistry , Antibodies, Monoclonal, Humanized/immunology , Antibodies, Monoclonal, Humanized/metabolism , Ion Mobility Spectrometry/methods , Humans , Mass Spectrometry/methods , Protein Binding , Antibodies, Monoclonal/chemistry , Antibodies, Monoclonal/immunology , Protein Multimerization
15.
J Physiol Pharmacol ; 75(2): 215-222, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38736268

ABSTRACT

The analysis of volatile organic compounds (VOCs) present in various biological samples holds immense potential for non-invasive disease diagnostics and metabolic profiling. One of the biological fluids that are suitable for use in clinical practice is urine. Given the limited quantity of VOCs in the urine headspace, it's imperative to enhance their extraction into the gaseous phase and prevent any degradation of VOCs during the thawing process. The study aimed to test several key parameters (incubation time, temperature, and thawing) that can influence urine volatilome and monitor selected VOCs for their stability. The analysis in this study was performed using a BreathSpec® (G.A.S., Dortmund, Germany) device consisting of a gas chromatograph (GC) coupled with an ion mobility spectrometer (IMS). Testing three different temperatures and incubation times yielded a low number of VOCs (9 out of 34) that exhibited statistically significant differences. However, examining three thawing conditions revealed no VOCs with statistically significant changes. Thus, we conclude that urine composition remains relatively stable despite exposure to various thermal stresses.


Subject(s)
Ion Mobility Spectrometry , Volatile Organic Compounds , Volatile Organic Compounds/urine , Volatile Organic Compounds/analysis , Humans , Pilot Projects , Ion Mobility Spectrometry/methods , Male , Adult , Gas Chromatography-Mass Spectrometry/methods , Female , Temperature , Young Adult , Middle Aged
16.
World J Urol ; 42(1): 353, 2024 May 25.
Article in English | MEDLINE | ID: mdl-38795133

ABSTRACT

PURPOSE: Despite many efforts, no reliable urinary marker system has so far shown the potential to substitute cystoscopy. Measuring volatile organic compounds (VOCs) from urine is a promising alternative. VOCs are metabolic products which can be measured from the headspace of urine samples. Previous studies confirmed that the urine of bladder tumor patients has a different VOC profile than healthy controls. In this pilot study, the feasibility of discriminating VOCs from urine of bladder cancer patients from that of healthy control subjects was investigated. Aim of this study was to investigate whether VOC-based diagnosis of bladder cancer from urine samples is feasible using multicapillary column ion mobility spectrometry (MCC/IMS) and to identify potential molecular correlates to the relevant analytes. METHODS: Headspace measurements of urine samples of 30 patients with confirmed transitional cell carcinoma (TCC) and 30 healthy controls were performed using MCC/IMS. In the results of the measurements, peaks showing significant differences between both groups were identified and implemented into a decision tree with respect to achieve group separation. Molecular correlates were predicted using a pre-defined dataset. RESULTS: Eight peaks with significantly differing intensity were identified, 5 of which were highly significant. Using a six-step decision tree, MCC/IMS showed a sensitivity of 90% and specificity of 100% in group separation. CONCLUSION: VOC-based detection of bladder cancer is feasible. MCC/IMS is a suitable method for urine-based diagnosis and should be further validated. The molecular characteristics and metabolic background of the analytes require further workup.


Subject(s)
Carcinoma, Transitional Cell , Ion Mobility Spectrometry , Urinary Bladder Neoplasms , Volatile Organic Compounds , Humans , Urinary Bladder Neoplasms/urine , Urinary Bladder Neoplasms/diagnosis , Volatile Organic Compounds/urine , Pilot Projects , Ion Mobility Spectrometry/methods , Male , Female , Aged , Middle Aged , Carcinoma, Transitional Cell/urine , Carcinoma, Transitional Cell/diagnosis , Feasibility Studies , Aged, 80 and over , Biomarkers, Tumor/urine
17.
Rapid Commun Mass Spectrom ; 38(15): e9775, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-38807480

ABSTRACT

RATIONALE: Spironolactone is a steroidal drug prescribed for a variety of medical conditions and is extensively metabolized quickly after administration. Measurement of spironolactone and its metabolites remains challenging using mass spectrometry (MS) due to in-source fragmentation and relatively poor ionization using electrospray ionization. Therefore, improved methods of measurements are needed, particularly in the case of small sample volumes. METHODS: Girard's reagent P (GP) derivatization of spironolactone was employed to improve response and provide an MS-based solution to the measurement of spironolactone and its metabolites. We performed ultra-high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UHPLC-ESI-MS/MS) and ion mobility spectrometry (IMS)-high-resolution mass spectrometry (HRMS) to fully characterize the GP derivatization products. Analytes were studied in positive ionization mode, and MS/MS was performed using nonresonance and resonance excitation collision-induced dissociation. RESULTS: We observed the successful GP derivatization of spironolactone and its metabolites using authentic chemical standards. A signal enhancement of 1-2 orders of magnitude was observed for GP-derivatized versions of spironolactone and its metabolites. Further, GP derivatization eliminated in-source fragmentation. Finally, we performed GP derivatization and ultra-high-performance liquid chromatography-high-resolution mass spectrometry (UHPLC-HRMS) in a small volume of murine serum (20 µL) from spironolactone-treated and control animals and observed multiple spironolactone metabolites only in the spironolactone-treated group. CONCLUSIONS: GP derivatization was proven to have advantageous mass spectral performance (e.g., limiting in-source fragmentation, enhancing signals, and eliminating isobaric analytes) for spironolactone and its metabolites. This work and the detailed characterization using ultra-high-performance liquid chromatography-high-resolution tandem mass spectrometry (UHPLC-HRMS/MS) and IMS serve as the foundation for future developments in reaction optimization and/or quantitative assay development.


Subject(s)
Ion Mobility Spectrometry , Spectrometry, Mass, Electrospray Ionization , Spironolactone , Tandem Mass Spectrometry , Spironolactone/chemistry , Spironolactone/blood , Spironolactone/metabolism , Chromatography, High Pressure Liquid/methods , Animals , Tandem Mass Spectrometry/methods , Mice , Spectrometry, Mass, Electrospray Ionization/methods , Ion Mobility Spectrometry/methods , Male
18.
Anal Chem ; 96(19): 7380-7385, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38693701

ABSTRACT

Ion mobility-mass spectrometry (IM-MS) offers benefits for lipidomics by obtaining IM-derived collision cross sections (CCS), a conditional property of an ion that can enhance lipid identification. While drift tube (DT) IM-MS retains a direct link to the primary experimental method to derive CCS values, other IM technologies rely solely on external CCS calibration, posing challenges due to dissimilar chemical properties between lipids and calibrants. To address this, we introduce MobiLipid, a novel tool facilitating the CCS quality control of IM-MS lipidomics workflows by internal standardization. MobiLipid utilizes a newly established DTCCSN2 library for uniformly (U)13C-labeled lipids, derived from a U13C-labeled yeast extract, containing 377 DTCCSN2 values. This automated open-source R Markdown tool enables internal monitoring and straightforward compensation for CCSN2 biases. It supports lipid class- and adduct-specific CCS corrections, requiring only three U13C-labeled lipids per lipid class-adduct combination across 10 lipid classes without requiring additional external measurements. The applicability of MobiLipid is demonstrated for trapped IM (TIM)-MS measurements of an unlabeled yeast extract spiked with U13C-labeled lipids. Monitoring the CCSN2 biases of TIMCCSN2 values compared to DTCCSN2 library entries utilizing MobiLipid resulted in mean absolute biases of 0.78% and 0.33% in positive and negative ionization mode, respectively. By applying the CCS correction integrated into the tool for the exemplary data set, the mean absolute CCSN2 biases of 10 lipid classes could be reduced to approximately 0%.


Subject(s)
Lipidomics , Lipids , Mass Spectrometry , Lipidomics/methods , Lipids/chemistry , Lipids/analysis , Ion Mobility Spectrometry/methods , Quality Control , Reference Standards , Saccharomyces cerevisiae/chemistry , Saccharomyces cerevisiae/metabolism
19.
J Cardiol ; 84(2): 146-148, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38621579

ABSTRACT

INTRODUCTION: Acute decompensated heart failure (ADHF) is a global health problem and early detection of high-risk patients for effective treatment is important. Exhaled breath analysis and measurement of volatile organic compounds (VOCs) may be a fast and cost-effective non-invasive diagnostic and screening tool complementing measurement of cardiac biomarkers. Another technique to detect and characterize VOCs is the ion mobility spectrometry (IMS) not requiring vacuum or sample pretreatment. METHODS: This prospective controlled proof-of-concept study prospectively enrolled adult patients with severe ADHF at the University Hospital Heart Centre Brandenburg. Severe ADHF was defined as patients presenting with symptomatic acute decompensation and NTproBNP >7000 pg/dL. Cardiac patients with NT-proBNP 220 pg/dL served as control. A gas chromatography ion mobility spectrometer (GC-IMS) of the type "MultiMarkerMonitor™" from GRAUPNER medical solutions GmbH was used. Measurement was performed at T0 (within 24 h of admission), T1 (after 3-5 days) and T2 (after 8-10 days). RESULTS: Forty patients were enrolled in the study, 20 patients with severe ADHF and 20 control patients. In patients with severe ADHF, three clusters with significantly altered maximum peak heights were detected compared to control. There was no change in the peak height of clusters 8, 9 and 206 at the time points T1 and T2 (all p > 0.50). Also, NT-proBNP was stable over time (p = 0.247). Sixteen control patients (16/20, 80 %) and four with severe ADHF (4/20, 20 %) presented without cluster deviation. Patients with deviation in at least two clusters had longer hospital stay, 11 days (5.0-15.0) compared to those without deviation, 4 days (2.0-9.5), p = 0.028. CONCLUSION: Longer-term follow-up studies are needed to assess the stability and clinical significance of the identified clusters by IMS and their diagnostic and prognostic relevance.


Subject(s)
Biomarkers , Breath Tests , Heart Failure , Natriuretic Peptide, Brain , Volatile Organic Compounds , Humans , Volatile Organic Compounds/analysis , Male , Pilot Projects , Female , Prospective Studies , Aged , Acute Disease , Breath Tests/methods , Natriuretic Peptide, Brain/blood , Biomarkers/analysis , Middle Aged , Cluster Analysis , Peptide Fragments/analysis , Peptide Fragments/blood , Severity of Illness Index , Ion Mobility Spectrometry , Aged, 80 and over , Proof of Concept Study
20.
J Am Soc Mass Spectrom ; 35(6): 1076-1088, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38660944

ABSTRACT

A recently developed proteolytic reactor, designed for protein structural investigation, was coupled to ion mobility mass spectrometry to monitor collisional cross section (CCS) evolution of model proteins undergoing trypsin-mediated mono enzymatic digestion. As peptides are released during digestion, the CCS of the remaining protein structure may deviate from the classical 2/3 power of the CCS-mass relationship for spherical structures. The classical relationship between CCS and mass (CCS = A × M2/3) for spherical structures, assuming a globular shape in the gas phase, may deviate as stabilizing elements are lost during digestion. In addition, collision-induced unfolding (CIU) experiments on partially digested proteins provided insights into the CCS resilience in the gas phase to ion activation, potentially due to the presence of stabilizing elements. The study initially investigated a model peptide ModBea (3 kDa), assessing the impact of disulfide bridges on CCS resilience in both reduced and oxidized forms. Subsequently, ß-lactoglobulin (2 disulfide bridges), calmodulin (Ca2+ coordination cation), and cytochrome c (heme) were selected to investigate the influence of common structuring elements on CCS resilience. CIU experiments probed the unfolding process, evaluating the effect of losing specific peptides on the energy landscapes of partially digested proteins. Comparisons of the TWCCSN2→He to trend curves describing the CCS/mass relationship revealed that proteins with structure-stabilizing elements consistently exhibit TWCCSN2→He and greater resilience toward CIU compared to proteins lacking these elements. The integration of online digestion, ion mobility, and CIU provides a valuable tool for identifying structuring elements in biopolymers in the gas phase.


Subject(s)
Calmodulin , Ion Mobility Spectrometry , Protein Unfolding , Proteins , Ion Mobility Spectrometry/methods , Proteins/chemistry , Calmodulin/chemistry , Calmodulin/metabolism , Lactoglobulins/chemistry , Lactoglobulins/metabolism , Cytochromes c/chemistry , Cytochromes c/analysis , Mass Spectrometry/methods , Peptides/chemistry , Peptides/analysis , Trypsin/chemistry , Trypsin/metabolism , Animals , Protein Conformation
SELECTION OF CITATIONS
SEARCH DETAIL
...