Zhonghua Er Ke Za Zhi ; 62(6): 535-541, 2024 Jun 02.
Article in Chinese | MEDLINE | ID: mdl-38763875

ABSTRACT

Objective: To evaluate the diagnostic efficacy and practicality of the Jaundice color card (JCard) as a screening tool for neonatal jaundice. Methods: Following the standards for reporting of diagnostic accuracy studies (STARD) statement, a multicenter prospective study was conducted in 9 hospitals in China from October 2019 to September 2021. A total of 845 newborns who were admitted to the hospital or outpatient department for liver function testing due to their own diseases. The inclusion criteria were a gestational age of ≥35 weeks, a birth weight of ≥2 000 g, and an age of ≤28 days. The neonate's parents used the JCard to measure jaundice at the neonate's cheek. Within 2 hours of the JCard measurement, transcutaneous bilirubin (TcB) was measured with a JH20-1B device and total serum bilirubin (TSB) was detected. The Pearson's correlation analysis, Bland-Altman plots and the receiver operating characteristic (ROC) curve were used for statistic analysis. Results: Out of the 854 newborns, 445 were male and 409 were female; 46 were born at 35-36 weeks of gestational age and 808 were born at ≥37 weeks of gestational age. Additionally, 432 cases were aged 0-3 days, 236 cases were aged 4-7 days, and 186 cases were aged 8-28 days. The TSB level was (227.4±89.6) µmol/L, with a range of 23.7-717.0 µmol/L. The JCard level was (221.4±77.0) µmol/L and the TcB level was (252.5±76.0) µmol/L. Both the JCard and TcB values showed good correlation (r=0.77 and 0.80, respectively) and agreements (96.0% (820/854) and 95.2% (813/854) of samples fell within the 95% limits of agreement, respectively) with TSB. The JCard value of 12 had a sensitivity of 0.93 and specificity of 0.75 for identifying a TSB ≥205.2 µmol/L, and a sensitivity of 1.00 and specificity of 0.35 for identifying a TSB ≥342.0 µmol/L. The TcB value of 205.2 µmol/L had a sensitivity of 0.97 and specificity of 0.60 for identifying TSB levels of 205.2 µmol/L, and a sensitivity of 1.00 and specificity of 0.26 for identifying TSB levels of 342.0 µmol/L. The areas under the ROC curve (AUC) of JCard for identifying TSB levels of 153.9, 205.2, 256.5, and 342.0 µmol/L were 0.96, 0.92, 0.83, and 0.83, respectively. The AUC of TcB were 0.94, 0.91, 0.86, and 0.87, respectively. There were both no significant differences between the AUC of JCard and TcB in identifying TSB levels of 153.9 and 205.2 µmol/L (both P>0.05). However, the AUC of JCard were both lower than those of TcB in identifying TSB levels of 256.5 and 342.0 µmol/L (both P<0.05). Conclusions: JCard can be used to classify different levels of bilirubin, but its diagnostic efficacy decreases with increasing bilirubin levels. When TSB level are ≤205.2 µmol/L, its diagnostic efficacy is equivalent to that of the JH20-1B. To prevent the misdiagnosis of severe jaundice, it is recommended that parents use a low JCard score, such as 12, to identify severe hyperbilirubinemia (TSB ≥342.0 µmol/L).


Subject(s)
Bilirubin , Hyperbilirubinemia, Neonatal , Jaundice, Neonatal , Sensitivity and Specificity , Humans , Infant, Newborn , Bilirubin/blood , Prospective Studies , Female , Male , Hyperbilirubinemia, Neonatal/diagnosis , Hyperbilirubinemia, Neonatal/blood , Jaundice, Neonatal/diagnosis , Jaundice, Neonatal/blood , ROC Curve , Neonatal Screening/methods , Gestational Age , Parents
2.
Cochrane Database Syst Rev ; 5: CD011060, 2024 05 28.
Article in English | MEDLINE | ID: mdl-38804265

ABSTRACT

BACKGROUND: The American Academy of Pediatrics and the Canadian Paediatric Society both advise that all newborns should undergo bilirubin screening before leaving the hospital, and this has become the standard practice in both countries. However, the US Preventive Task Force has found no strong evidence to suggest that this practice of universal screening for bilirubin reduces the occurrence of significant outcomes such as bilirubin-induced neurologic dysfunction or kernicterus. OBJECTIVES: To evaluate the effectiveness of transcutaneous screening compared to visual inspection for hyperbilirubinemia to prevent the readmission of newborns (infants greater than 35 weeks' gestation) for phototherapy. SEARCH METHODS: We searched CENTRAL, MEDLINE, Embase, CINAHL, ClinicalTrials.gov, ICTRP, and ISRCTN in June 2023. We also searched conference proceedings, and the reference lists of included studies. SELECTION CRITERIA: We included randomized controlled trials (RCTs), quasi-randomized, cluster-randomized, or prospective cohort studies with control arm that evaluated the use of transcutaneous bilirubin (TcB) screening for hyperbilirubinemia in newborns before hospital discharge. DATA COLLECTION AND ANALYSIS: We used standard methodologic procedures expected by Cochrane. We evaluated treatment effects using a fixed-effect model with risk ratio (RR) and 95% confidence intervals (CI) for categorical data and mean, standard deviation (SD), and mean difference (MD) for continuous data. We used the GRADE approach to evaluate the certainty of evidence. MAIN RESULTS: We identified one RCT (1858 participants) that met our inclusion criteria. The study included 1858 African newborns at 35 weeks' gestation or greater who were receiving routine care at a well-baby nursery, and were randomly recruited prior to discharge to undergo TcB screening. The study had good methodologic quality. TcB screening versus visual assessment of hyperbilirubinemia in newborns: - may reduce readmission to the hospital for hyperbilirubinemia (RR 0.25, 95% CI 0.14 to 0.46; P < 0.0001; moderate-certainty evidence); - probably has little or no effect on the rate of exchange transfusion (RR 0.20, 95% CI 0.01 to 14.16; low-certainty evidence); - may increase the number of newborns who require phototherapy prior to discharge (RR 2.67, 95% CI 1.56 to 4.55; moderate-certainty evidence). - probably has little or no effect on the rate of acute bilirubin encephalopathy (RR 0.33, 95% CI 0.01 to 8.18; low-certainty evidence). The study did not evaluate or report cost of care. AUTHORS' CONCLUSIONS: Moderate-certainty evidence suggests that TcB screening may reduce readmission for hyperbilirubinemia compared to visual inspection. Low-certainty evidence also suggests that TcB screening probably has little or no effect on the rate of exchange transfusion compared to visual inspection. However, moderate-certainty evidence suggests that TcB screening may increase the number of newborns that require phototherapy before discharge compared to visual inspection. Low-certainty evidence suggests that TcB screening probably has little or no effect on the rate of acute bilirubin encephalopathy compared to visual inspection. Given that we have only identified one RCT, further studies are necessary to determine whether TcB screening can help to reduce readmission and complications related to neonatal hyperbilirubinemia. In settings with limited newborn follow-up after hospital discharge, identifying newborns at risk of severe hyperbilirubinemia before hospital discharge will be important to plan targeted follow-up of these infants.


Subject(s)
Bilirubin , Infant, Premature , Jaundice, Neonatal , Neonatal Screening , Patient Readmission , Randomized Controlled Trials as Topic , Humans , Infant, Newborn , Bilirubin/blood , Jaundice, Neonatal/diagnosis , Jaundice, Neonatal/therapy , Jaundice, Neonatal/blood , Neonatal Screening/methods , Patient Readmission/statistics & numerical data , Bias , Hyperbilirubinemia, Neonatal/diagnosis , Hyperbilirubinemia, Neonatal/therapy , Phototherapy , Term Birth
3.
Biosensors (Basel) ; 14(5)2024 May 17.
Article in English | MEDLINE | ID: mdl-38785728

ABSTRACT

One of the most common problems many babies encounter is neonatal jaundice. The symptoms are yellowing of the skin or eyes because of bilirubin (from above 2.0 to 2.5 mg/dL in the blood). If left untreated, it can lead to serious neurological complications. Traditionally, jaundice detection has relied on invasive blood tests, but developing non-invasive biosensors has provided an alternative approach. This systematic review aims to assess the advancement of these biosensors. This review discusses the many known invasive and non-invasive diagnostic modalities for detecting neonatal jaundice and their limitations. It also notes that the recent research and development on non-invasive biosensors for neonatal jaundice diagnosis is still in its early stages, with the majority of investigations being in vitro or at the pre-clinical level. Non-invasive biosensors could revolutionize neonatal jaundice detection; however, a number of issues still need to be solved before this can happen. These consist of in-depth validation studies, affordable and user-friendly gadgets, and regulatory authority approval. To create biosensors that meet regulatory requirements, additional research is required to make them more precise and affordable.


Subject(s)
Biosensing Techniques , Jaundice, Neonatal , Humans , Jaundice, Neonatal/diagnosis , Infant, Newborn , Bilirubin/analysis
4.
BMC Health Serv Res ; 24(1): 671, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38807158

ABSTRACT

BACKGROUND: Neonatal jaundice is a common condition that can lead to brain damage and disabilities when severe cases go undetected. Low- and middle-income countries often lack accurate methods for detecting neonatal jaundice and rely on visual assessment, resulting in a higher incidence of adverse consequences. Picterus Jaundice Pro (Picterus JP), an easy-to-use and affordable smartphone-based screening device for the condition, has demonstrated higher accuracy than visual assessment in Norwegian, Philippine and Mexican newborns. This study aimed to identify the barriers and facilitators to implementing Picterus JP in public health services in low-income settings in Mexico by exploring the current process of neonatal jaundice detection and stakeholders' perspectives in that context. METHODS: Qualitative data collection techniques, including one focus group, 15 semi-structured interviews and four observations, were employed in urban and rural health facilities in Oaxaca, Mexico. The participants included medical doctors, nurses and health administrators. The data were analysed by thematic analysis guided by the Consolidated Framework for Implementation Research. RESULTS: The analysis yielded four main themes: (I) the current state of neonatal care and NNJ detection, (II) the needs and desires for enhancing NNJ detection, (III) the barriers and facilitators to implementing Picterus JP in the health system and (IV) HCWs' expectations of Picterus JP. The findings identify deficiencies in the current neonatal jaundice detection process and the participants' desire for a more accurate method. Picterus JP was perceived as easy to use, useful and compatible with the work routine, but barriers to adoption were identified, including internet deficiencies and costs. CONCLUSIONS: The introduction of Picterus JP as a supporting tool to screen for neonatal jaundice is promising but contextual barriers in the setting must be addressed for successful implementation. There is also an opportunity to optimise visual assessment to improve detection of neonatal jaundice.


Subject(s)
Focus Groups , Jaundice, Neonatal , Qualitative Research , Telemedicine , Humans , Jaundice, Neonatal/diagnosis , Infant, Newborn , Mexico , Neonatal Screening/methods , Female , Male , Developing Countries , Interviews as Topic , Smartphone
5.
Eur J Pediatr ; 183(7): 2819-2830, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38581462

ABSTRACT

Measurement of transcutaneous bilirubin (TcB) is a non-invasive, widely used technique to estimate serum bilirubin (SB). However, its reliability in multiethnic populations during and after phototherapy is still controversial even in covered skin. The aim of this study was to determine the reliability of TcB in covered (cTcB) and exposed (eTcB) skin during and after phototherapy in a multiethnic population of term and preterm neonates according to Neomar's neonatal skin color scale. Prospective, observational study comparing SB and TcB. We determined SB when clinically indicated and, at the same time, measured cTcB under a photo-opaque patch and eTcB next to it with a jaundice meter (Dräger JM-105TM). All dyads TcB-SB were compared, both globally and according to skin color. We obtained data from 200 newborns (color1: 44, color2: 111, color3: 41, color4: 4) and compared 296 dyads TcB/SB. Correlation between cTcB and SB is strong during (0.74-0.83) and after (0.79-0.88) phototherapy, both globally and by color group. The SB-cTcB bias depends on gestational age during phototherapy and on skin color following phototherapy. The correlation between eTcB and SB during phototherapy is not strong (0.54), but becomes so 12 h after discontinuing phototherapy (0.78).  Conclusions: Our study supports the reliability of cTcB to assess SB during and after phototherapy, with differences among skin tones after the treatment. The use of cTcB and Neomar's scale during and mainly after phototherapy may help reduce the number of blood samples required. What is Known: • Controversies exist on the reliability of jaundice meters during and after phototherapy in covered skin. Only a few studies have analyzed their accuracy in multiethnic populations, but none has used a validated neonatal skin color scale. What is New: • We verified correlation between serum and transcutaneous bilirubin in covered skin in a multiethnic population depending on skin color based on our own validated neonatal skin color scale during and after phototherapy.


Subject(s)
Bilirubin , Jaundice, Neonatal , Phototherapy , Skin Pigmentation , Humans , Bilirubin/blood , Bilirubin/analysis , Infant, Newborn , Prospective Studies , Reproducibility of Results , Female , Phototherapy/methods , Jaundice, Neonatal/therapy , Jaundice, Neonatal/blood , Jaundice, Neonatal/diagnosis , Male , Neonatal Screening/methods , Infant, Premature , Gestational Age
6.
S Afr Fam Pract (2004) ; 66(1): e1-e5, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38572885

ABSTRACT

Persistent challenges in addressing severe neonatal hyperbilirubinaemia in resource-constrained settings have led to ongoing and often unacceptable rates of morbidity, disability and mortality. These challenges stem from limitations such as inadequate, inefficient or financially inaccessible diagnostic and therapeutic options. However, over the past decade, noteworthy innovations have emerged to address some of these hurdles, and these innovations are increasingly poised for broader implementation. This review provides a concise summary of these novel, economically viable diagnostic solutions, encompassing point-of-care assays and smartphone applications, as well as treatment modalities, notably more effective phototherapy and filtered sunlight. These advancements hold promise and have the potential to meaningfully reduce the burden of neonatal hyperbilirubinaemia, signifying a promising shift in the landscape of neonatal healthcare.


Subject(s)
Hyperbilirubinemia, Neonatal , Jaundice, Neonatal , Infant, Newborn , Humans , Jaundice, Neonatal/diagnosis , Jaundice, Neonatal/therapy , Hyperbilirubinemia, Neonatal/diagnosis , Hyperbilirubinemia, Neonatal/therapy , Phototherapy , Sunlight , Longitudinal Studies
7.
PLoS One ; 19(4): e0301512, 2024.
Article in English | MEDLINE | ID: mdl-38574088

ABSTRACT

BACKGROUND: Neonatal jaundice (NNJ) is a major contributor to childhood morbidity and mortality. As many infants are discharged by 24 hours of age, mothers are key in detecting severe forms of jaundice. Mothers with limited knowledge of NNJ have a hard time identifying these infants who could go on to have the worst outcomes. This study aimed to determine the effect of a jaundice education package delivered to mothers prior to hospital discharge on maternal knowledge after discharge. METHODS: This was a before and after interventional study involving an education package delivered through a video message and informational voucher. At 10-14 days after discharge, participants were followed up via telephone to assess their post-intervention knowledge. A paired t-test was used to determine the effectiveness of the intervention on knowledge improvement. Linear regression was used to determine predictors of baseline knowledge and of change in knowledge score. RESULTS: Of the 250 mothers recruited, 188 were fit for analysis. The mean knowledge score was 10.02 before and 14.61 after the intervention, a significant difference (p<0.001). Factors determining higher baseline knowledge included attendance of 4 or more antenatal visits (p < 0.001), having heard about NNJ previously (p < 0.001), having experienced an antepartum illness (p = 0.019) and higher maternal age (p = 0.015). Participants with poor baseline knowledge (ß = 7.523) and moderate baseline knowledge (ß = 3.114) had much more to gain from the intervention relative to those with high baseline knowledge (p < 0.001). CONCLUSION: Maternal knowledge of jaundice can be increased using a simple educational intervention, especially in settings where the burden of detection often falls on the mother. Further study is needed to determine the impact of this intervention on care seeking and infant outcomes.


Subject(s)
Jaundice, Neonatal , Jaundice , Infant, Newborn , Infant , Female , Humans , Pregnancy , Child , Mothers , Jaundice, Neonatal/therapy , Jaundice, Neonatal/diagnosis , Uganda , Health Knowledge, Attitudes, Practice , Hospitals , Referral and Consultation
8.
BMJ Case Rep ; 17(2)2024 Feb 14.
Article in English | MEDLINE | ID: mdl-38355207

ABSTRACT

Neonatal jaundice is a frequently observed occurrence in full-term newborns and typically manifests between 48 and 96 hours following birth. Early-onset jaundice is primarily induced by pathological factors, namely sepsis, hemolysis and an excessive accumulation of bilirubin resulting from the breakdown of red blood cells.We present a case involving a full-term newborn with an uneventful perinatal history, who exhibited jaundice within the initial day of life and was subsequently admitted to the neonatal intensive care unit to commence intensive phototherapy. Initial screenings for sepsis and blood group incompatibility yielded negative results. However, despite 6 hours of phototherapy, the bilirubin levels did not decrease, prompting an investigation into central nervous system haemorrhage, which uncovered the presence of a haemorrhagic stroke.After a worsening in neurological status with neonatal crisis and need for phenobarbital, a life-saving craniotomy was performed. Clinical evolution was good with no additional crisis detected after the early neonatal period and improvement in motor function at 2-month-old follow-up.


Subject(s)
Jaundice, Neonatal , Jaundice , Sepsis , Humans , Infant, Newborn , Infant , Jaundice, Neonatal/diagnosis , Jaundice, Neonatal/etiology , Jaundice, Neonatal/therapy , Bilirubin , Intensive Care Units, Neonatal , Phototherapy
10.
Ir Med J ; 117(1): 892, 2024 01 18.
Article in English | MEDLINE | ID: mdl-38259236

ABSTRACT

Background Physiological neonatal hyperbilirubinemia is a normal transitional phenomenon, however bilirubin encephalopathy can develop due to exposure to very high bilirubin levels. A systematic approach to early detection of high levels can prevent this outcome. Methods We designed a questionnaire to assess local jaundice management practices in Irish maternity units. Results All 19 units responded to our clinical questionnaire. Early discharge (<48 hours) occurs in 12 units (63%). Six units universally screen all babies with a transcutaneous bilirubinometer (TCB) (32%) while 12 units only do so if clinically jaundiced (83%). 12 units follow up <5% of their babies for jaundice monitoring after discharge (67%), which is lower than expected for optimal jaundice management. Conclusion Our survey responses show a high degree of variability in jaundice identification and follow up practices around the country. As maternity units trend towards earlier discharge of mothers due to resource constraints, we need to develop national systems to stratify risk before discharge and monitor jaundice in the out-patient setting. Introduction


Subject(s)
Jaundice, Neonatal , Infant, Newborn , Humans , Jaundice, Neonatal/diagnosis , Jaundice, Neonatal/therapy
11.
Klin Padiatr ; 236(1): 31-38, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37647914

ABSTRACT

OBJECTIVE: This study aims to examine the accuracy of transcutaneous bilirubin (TcB) in estimating the total serum bilirubin (TSB) level at five different sites before and immediately after phototherapy. METHODS: This study prospectively enrolled infants with a gestational age of 34 to 416/7 weeks who were clinically diagnosed with neonatal jaundice and required phototherapy within 28 days after birth. TcB levels were measured on the uncovered four areas (forehead, mid-sternum, abdomen, and interscapular site) and covered hipbone by using the Dräger JM-103 Jaundice Meter before phototherapy and at 0 min after discontinuing phototherapy. Correlation and agreement between TcB and TSB levels were assessed before and after phototherapy. RESULTS: We included 108 infants with a mean gestational age of 37.6±1.5 weeks and birth weight of 3108±548 g. A strong significant correlation was found between TSB and TcB measurements at all five sites before phototherapy with the strongest correlation at the interscapular site (r=0.768, p=0.001). The correlation was weakened between TSB and TcB at all five sites after phototherapy; however, the strongest correlation was at the covered hipbone (r=0.619, p=0.001). TcB measurements at all five sites tended to underestimate TSB levels before and after phototherapy. The difference (TcB - TSB) tended to increase with increasing TSB levels. CONCLUSIONS: TcB levels were most accurately measured at the interscapular site and covered hipbone before and immediately after phototherapy, respectively.


Subject(s)
Jaundice, Neonatal , Skin , Infant , Infant, Newborn , Humans , Jaundice, Neonatal/diagnosis , Jaundice, Neonatal/therapy , Gestational Age , Bilirubin , Phototherapy , Neonatal Screening
12.
Arch Pathol Lab Med ; 148(2): e40-e47, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-37596896

ABSTRACT

CONTEXT.­: Total serum bilirubin (TSB) analysis is pivotal for diagnosing neonatal hyperbilirubinemia. Because of a routine change in laboratory equipment, our TSB assay changed from a diazo to a vanadate oxidase method. Upon implementation, TSB results were substantially higher in newborns than expected based on the validation. OBJECTIVE.­: To investigate the application of TSB and intermethod differences in neonates and their impact on phototherapy treatment. DESIGN.­: The diazo and vanadate methods were compared directly using neonatal and adult samples. Anonymized external quality control data were analyzed to explore interlaboratory differences among 8 commercial TSB assays. Clinical patient data were extracted from the medical records to investigate the number of newborns receiving phototherapy. RESULTS.­: The mean bias of the vanadate versus the diazo TSB method was +17.4% and +3.7% in neonatal and adult samples, respectively. External quality control data showed that the bias of commercial TSB methods compared with the reference method varied from -3.6% to +20.2%. Within-method variation ranged from 5.2% to 16.0%. After implementation of the vanadate TSB method, the number of neonates treated with phototherapy increased approximately threefold. CONCLUSIONS.­: Currently available TSB assays lack harmonization for the diagnosis of neonatal hyperbilirubinemia. Between-methods differences are substantially higher in neonatal compared with adult samples, highlighting the importance of including neonatal samples during assay validation. Close collaboration between laboratory specialists and clinicians is essential to prevent overtreatment or undertreatment upon the implementation of novel analyzers or assays. Also, harmonization of TSB assays, with an emphasis on neonatal application, is warranted.


Subject(s)
Hyperbilirubinemia, Neonatal , Jaundice, Neonatal , Humans , Infant, Newborn , Jaundice, Neonatal/diagnosis , Jaundice, Neonatal/epidemiology , Jaundice, Neonatal/therapy , Incidence , Vanadates , Bilirubin , Hyperbilirubinemia, Neonatal/diagnosis , Hyperbilirubinemia, Neonatal/epidemiology , Hyperbilirubinemia, Neonatal/therapy , Phototherapy/adverse effects , Phototherapy/methods
13.
J Matern Fetal Neonatal Med ; 37(1): 2295808, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38146169

ABSTRACT

OBJECTIVE: To test the accuracy of transcutaneous bilirubinometry (TcB) in neonates 12 h after discontinuing phototherapy. STUDY DESIGN: In a prospective study of 91 neonates at ≥35 weeks of gestation, paired measurements of total serum bilirubin (TSB) and TcB were obtained 12 h after discontinuation of phototherapy. TcB measurements were obtained on the uncovered skin of the sternum and the covered skin of the lower abdomen. Bland-Altman plots were used to evaluate agreement between TSB and TcB. RESULTS: TcB was found to systematically underestimate TSB on both covered and uncovered skin. The smallest but statistically significant difference between TSB and TcB was found on the covered lower abdomen (-1.03, p < .0001) compared with the uncovered skin of the sternum (-1.44, p < .0001). The correlation between TSB and TcB was excellent on both covered (r = 0.86, p < .001) and uncovered skin (r = 0.90, p < .001). Bland and Altman plots showed poor agreement between TcB and TSB. CONCLUSIONS: This study demonstrated excellent correlation between TcB and TSB 12 h after phototherapy but poor TcB-TSB agreement. TcB cannot be reliably used in neonates exposed to phototherapy.


Subject(s)
Jaundice, Neonatal , Humans , Infant, Newborn , Bilirubin , Jaundice, Neonatal/diagnosis , Jaundice, Neonatal/therapy , Neonatal Screening , Phototherapy , Prospective Studies , Skin
14.
JMIR Mhealth Uhealth ; 11: e53291, 2023 12 22.
Article in English | MEDLINE | ID: mdl-38153797

ABSTRACT

Background: Neonatal jaundice (NNJ) or hyperbilirubinemia is a ubiquitous condition in newborn infants. Currently, the transcutaneous bilirubinometer is used to screen for NNJ in health care facilities, where neonates need to be physically present (ie, a centralized model of care for NNJ screening). Mobile health (mHealth) apps present a low-cost, home-based, and noninvasive system that could facilitate self-monitoring of NNJ and could allow mothers the convenience of screening for NNJ remotely. However, end users' acceptability of such mHealth apps is of fundamental importance before the incorporation of such apps into clinical practice. Objective: The study aimed to explore the perception of postpartum mothers toward self-monitoring of NNJ using a novel mHealth app. Methods: Mothers attending video consultations for early postpartum care at 2 Singapore primary care clinics watched an instructional video for a hyperbilirubinemia-screening mHealth app (HSMA). An independent researcher used a semistructured topic guide to conduct in-depth interviews with 25 mothers, assessing their views on HSMAs. All interviews were audio recorded, transcribed verbatim, and checked for accuracy before data analysis. Two researchers independently analyzed the transcripts via thematic analysis. Data were managed using NVivo qualitative data management software. Results: The identified themes were grouped under perceived usability and utility. Mothers valued the convenience and utility of HSMAs for remote monitoring of NNJ. They appreciated the objectivity the app readings provided compared to visual inspection. However, they perceived that the app's applicability would be restricted to severe jaundice, were concerned about its accuracy and restriction to the English language, and lacked confidence in using it. Nevertheless, they were willing to use it once its accuracy was proven and when they received adequate guidance from health care professionals. They also suggested including an action plan for the measured readings and clinical signs within the app. Mothers proposed pairing teleconsultations with HSMAs to boost their confidence and enhance adoption. Conclusions: Mothers were receptive to using HSMAs but had concerns. Multiple languages, proof of accuracy, and resources to guide users should be incorporated into the app in the next phase to increase its successful adoption. Complementing such apps with a teleconsultation service presents a plausible and pragmatic NNJ care delivery model in general practice.


Subject(s)
Jaundice, Neonatal , Mobile Applications , Female , Infant, Newborn , Humans , Jaundice, Neonatal/diagnosis , Qualitative Research , Hyperbilirubinemia , Postpartum Period
15.
Pediatrics ; 152(6)2023 Dec 01.
Article in English | MEDLINE | ID: mdl-37990609

ABSTRACT

CONTEXT: Transcutaneous bilirubinometry (TcB) is used as a valid screening to identify neonates requiring measurement of total serum bilirubin (TSB) before phototherapy. Its use during and after phototherapy is not advised yet because of unknown reliability. OBJECTIVES: To determine the agreement of TcB and TSB measurements before, during, and after phototherapy. DATA SOURCES: PubMed Medline, Cochrane Library, and references of eligible studies were searched. STUDY SELECTION: Prospective and retrospective cohort and cross-sectional studies reporting Bland-Altman statistics of paired TcB and TSB measurements in term and preterm newborns. DATA EXTRACTION: Meta-analysis was performed using the Mantel-Haenszel weighted approach. The agreement between TcB and TSB in µmol/L was described by pooled mean differences (MDs) and limits of agreement (LoA). RESULTS: Fifty-four studies were included. The pooled MD before phototherapy is 2.5 µmol/L (LoA -38.3 to 43.3). The pooled MD during phototherapy is -0.3 µmol/L (LoA -34.8 to 34.2) on covered skin and -28.6 µmol/L (LoA -105.7 to 48.5) on uncovered skin. The pooled MD after phototherapy is -34.3 µmol/L (LoA -86.7 to 18.1) on covered skin and -21.1 µmol/L (LoA -88.6 to 46.4) on uncovered skin. Subgroup analysis revealed the best agreement at the forehead. We did not find any difference in agreement between term and preterm neonates. LIMITATIONS: Language restriction. CONCLUSIONS: TcB measurements before and during phototherapy on covered skin show good agreement compared with TSB in term and preterm newborns. More studies are needed to evaluate the accuracy after phototherapy.


Subject(s)
Jaundice, Neonatal , Infant, Newborn , Humans , Jaundice, Neonatal/diagnosis , Jaundice, Neonatal/therapy , Bilirubin , Prospective Studies , Reproducibility of Results , Retrospective Studies , Cross-Sectional Studies , Phototherapy , Neonatal Screening
16.
Pediatr Int ; 65(1): e15617, 2023.
Article in English | MEDLINE | ID: mdl-37658617

ABSTRACT

BACKGROUND: This nationwide survey aimed to determine the status of jaundice management in Japan. METHODS: A questionnaire about bilirubin level measurements and neonatal jaundice treatment was sent to 330 institutions providing neonatal care. The responses were analyzed according to institution level. RESULTS: Of 330 institutions, 172 responded (52.1% response rate). Total bilirubin levels were measured in the central laboratory using spectrophotometry at 134 institutions and a blood gas analyzer at 81 institutions. Unbound bilirubin (UB) levels were measured by 79 institutions, while transcutaneous bilirubin measurements were taken at 63 institutions. There was no association between institution level and UB or transcutaneous bilirubin measurement. For phototherapy criteria, the Murata-Imura criteria were adopted by 67 institutions, Nakamura criteria by 36, and Morioka criteria by 39. Light-emitting diodes (LED) were used by 160 institutions versus fluorescent lights by 31. When a blue LED was used, 119 institutions used the high mode. There is no standard for increasing light intensity. No association was found between institution level and phototherapy criteria. UB was measured in 14 of 63 institutions using the Murata-Imura criteria. CONCLUSIONS: There is a large variation in the management and treatment of neonatal jaundice among institutes in Japan.


Subject(s)
Jaundice, Neonatal , Infant, Newborn , Humans , Jaundice, Neonatal/diagnosis , Jaundice, Neonatal/therapy , Japan , Exchange Transfusion, Whole Blood , Phototherapy , Bilirubin
17.
Turk J Med Sci ; 53(2): 511-517, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37476881

ABSTRACT

BACKGROUND: The aim of this study is to determine the value of the questions asked in routine follow-up, the cord blood bilirubin (CBB) and bilirubin/albumin (B/A) ratio in estimating the risk of developing hyperbilirubinemia. METHODS: Term and healthy 217 newborns whose CBB and albumin could be obtained and whose needed to be measured bilirubin level at the 24thand 72nd hours of life were included. Nutrition, sex and nationality, consanguinity between parents, jaundice in the sibling (s), mother's medications were questioned. CBB and albumin, serum total bilirubin (STB), serum albumin and transcutaneous bilirubin (TcB) at the 24th and 72nd hours of life, were recorded. RESULTS: CBB and cord B/A ratio, STB and serum B/A ratio, and TcB at the 24th and 72nd hours were found to be higher in the babies who received the phototherapy (p < 0.001 for all). The moderate positive correlation (correlation coefficient 0.383) at the 24th hour and strong positive correlation (correlation coefficient 0.759) at the 72nd hour between STB and TcB measurements was detected. In estimating the need for phototherapy the sensitivity and specificity of CBB were 74.2% and 56.5%, the sensitivity and specifity of cord B/A was 74.2%, and 61.8%. The cut-off value of CBB in estimating the need for phototherapy is 1.8, and the cut-off value of the cord B/A ratio is 0.56. When the cut-off value is 1.8 for the CCB and the cord B/A ratio is 0.56, the positive predictive values are low, but the negative predictive values are significantly high (92.9% and 93.5%, respectively) in determining the need for phototherapy. DISCUSSION: CBB and B/A ratio are important in predicting the possibility of indirect hyperbilirubinemia (IHB) development. Babies should be followed closely in terms of IHB development when their CBB value is 1.8 mg/dL and above, and the cord blood B/A ratio is 0.56 and above.


Subject(s)
Jaundice, Neonatal , Infant, Newborn , Humans , Jaundice, Neonatal/diagnosis , Bilirubin , Hyperbilirubinemia , Serum Albumin , Umbilical Cord , Neonatal Screening
18.
BMJ Paediatr Open ; 7(1)2023 06.
Article in English | MEDLINE | ID: mdl-37385734

ABSTRACT

BACKGROUND: Since most infants are usually discharged before age 48-72 hours, peak bilirubin levels will almost always occur after discharge. Parents may be the first to observe the onset of jaundice after discharge, but visual assessment is unreliable. The jaundice colour card (JCard) is a low-cost icterometer designed for the assessment of neonatal jaundice. The objective of this study was to evaluate parental use of JCard to detect jaundice in neonates. METHODS: We conducted a multicentre, prospective, observational cohort study in nine sites across China. A total of 1161 newborns ≥35 weeks of gestation were enrolled in the study. Measurements of total serum bilirubin (TSB) levels were based on clinical indications. The JCard measurements by parents and paediatricians were compared with the TSB. RESULTS: JCard values of parents and paediatricians were correlated with TSB (r=0.754 and 0.788, respectively). The parents' and paediatricians' JCard values 9 had sensitivities of 95.2% vs 97.6% and specificities of 84.5% vs 71.7% for identifying neonates with TSB ≥153.9 µmol/L. The parents' and paediatricians' JCard values 15 had sensitivities of 79.9% vs 89.0% and specificities of 66.7% vs 64.9% for identifying neonates with TSB ≥256.5 µmol/L. Areas under the receiver operating characteristic curves of parents for identifying TSB ≥119.7, ≥153.9, ≥205.2, and ≥256.5 µmol/L were 0.967, 0.960, 0.915, and 0.813, respectively, and those of paediatricians were 0.966, 0.961, 0.926 and 0.840, respectively. The intraclass correlation coefficient was 0.933 between parents and paediatricians. CONCLUSION: The JCard can be used to classify different levels of bilirubin, but it is less accurate with high bilirubin levels. The JCard diagnostic performance of parents was slightly lower than that of paediatricians.


Subject(s)
Jaundice, Neonatal , Aged , Humans , Infant , Infant, Newborn , Middle Aged , Bilirubin , Jaundice, Neonatal/diagnosis , Parents , Prospective Studies
19.
Arch Dis Child Educ Pract Ed ; 108(5): 377-384, 2023 10.
Article in English | MEDLINE | ID: mdl-37263765

ABSTRACT

At medical school, there is a phrase to help us remember that common things are common: 'If you hear hooves think horses, not zebras'. However, zebras do exist, and from time to time in general paediatric and neonatal practice, we will encounter these rare diagnoses, more of which we can now accurately diagnose through the ever-expanding field of genomics. Our case demonstrates how a rare diagnosis can present with common features of growth restriction, jaundice and anaemia. Paediatricians therefore require a high index of suspicion and increasing knowledge of the logistics of genetic testing.


Subject(s)
Anemia , Jaundice, Neonatal , Infant, Newborn , Humans , Horses , Animals , Child , Jaundice, Neonatal/diagnosis , Jaundice, Neonatal/therapy , Anemia/diagnosis , Anemia/etiology
20.
Am Fam Physician ; 107(5): 525-534, 2023 05.
Article in English | MEDLINE | ID: mdl-37192079

ABSTRACT

Neonatal jaundice due to hyperbilirubinemia is common, and most cases are benign. The irreversible outcome of brain damage from kernicterus is rare (1 out of 100,000 infants) in high-income countries such as the United States, and there is increasing evidence that kernicterus occurs at much higher bilirubin levels than previously thought. However, newborns who are premature or have hemolytic diseases are at higher risk of kernicterus. It is important to evaluate all newborns for risk factors for bilirubin-related neurotoxicity, and it is reasonable to obtain screening bilirubin levels in newborns with risk factors. All newborns should be examined regularly, and bilirubin levels should be measured in those who appear jaundiced. The American Academy of Pediatrics (AAP) revised its clinical practice guideline in 2022 and reconfirmed its recommendation for universal neonatal hyperbilirubinemia screening in newborns 35 weeks' gestational age or greater. Although universal screening is commonly performed, it increases unnecessary phototherapy use without sufficient evidence that it decreases the incidence of kernicterus. The AAP also released new nomograms for initiating phototherapy based on gestational age at birth and the presence of neurotoxicity risk factors, with higher thresholds than in previous guidelines. Phototherapy decreases the need for an exchange transfusion but has the potential for short- and long-term adverse effects, including diarrhea and increased risk of seizures. Mothers of infants who develop jaundice are also more likely to stop breastfeeding, even though discontinuation is not necessary. Phototherapy should be used only for newborns who exceed thresholds recommended by the current AAP hour-specific phototherapy nomograms.


Subject(s)
Hyperbilirubinemia, Neonatal , Jaundice, Neonatal , Kernicterus , Female , Infant, Newborn , Humans , United States , Child , Kernicterus/diagnosis , Kernicterus/etiology , Kernicterus/prevention & control , Hyperbilirubinemia, Neonatal/complications , Hyperbilirubinemia, Neonatal/diagnosis , Hyperbilirubinemia, Neonatal/therapy , Jaundice, Neonatal/diagnosis , Jaundice, Neonatal/etiology , Jaundice, Neonatal/therapy , Phototherapy , Bilirubin , Hyperbilirubinemia/complications