Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 14.393
1.
Int Ophthalmol ; 44(1): 231, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38822988

PURPOSE: To analyze the intraoperative challenges of cataract surgery in children, following glaucoma filtering surgery. METHODS: This was a retrospective study to analyze intra-op challenges and outcomes of pediatric cataract surgery in post-glaucoma filtration surgery eyes, between January 2007 and December 2019. RESULTS: We included 20 eyes of 16 children. The most common glaucoma surgery performed was trabeculectomy and trabeculotomy (14 eyes). The median age at the time of cataract surgery was 74.5 months. The most common cataract surgery performed was lens aspiration with posterior chamber intraocular lens implantation (LA + PCIOL) (9/20). The most common intraoperative challenge faced was difficulty in capsulorrhexis (ten eyes), followed by extension of primary posterior capsulotomy (six eyes). At the final follow up eight eyes had improvement in visual acuity, five eyes had stable visual acuity and five eyes had a drop in visual acuity. In 12/20 eyes IOL was implanted, nine eyes in-the-bag and three eyes had in ciliary sulcus. None of the IOLs in the bag had decentration of IOL. The median postoperative IOP (p = 0.12) and median number of postoperative AGM (p = 0.13) at 2 years remained stable compared to the preoperative values. The IOP remained well controlled in 4 eyes without anti-glaucoma medications and in 14 eyes with anti-glaucoma medications and none needed additional surgery for IOP control. Two eyes developed retinal detachment postoperatively. CONCLUSION: Cataract surgery in pediatric eyes with prior glaucoma surgeries, have challenges with capsulorrhexis and IOL stability. The visual outcomes were reasonably good so was the IOP control.


Cataract Extraction , Cataract , Glaucoma , Intraocular Pressure , Visual Acuity , Humans , Retrospective Studies , Male , Female , Cataract Extraction/methods , Cataract Extraction/adverse effects , Child , Child, Preschool , Intraocular Pressure/physiology , Glaucoma/surgery , Glaucoma/physiopathology , Cataract/complications , Filtering Surgery/methods , Follow-Up Studies , Treatment Outcome , Adolescent , Intraoperative Complications , Infant , Trabeculectomy/methods , Lens Implantation, Intraocular/methods
3.
Vestn Oftalmol ; 140(2): 34-39, 2024.
Article Ru | MEDLINE | ID: mdl-38742496

PURPOSE: This study evaluates the accuracy of modern intraocular lens (IOL) calculation formulas using axial length (AL) data obtained by ultrasound biometry (UBM) compared to the third-generation SRK/T calculator. MATERIAL AND METHODS: The study included 230 patients (267 eyes) with severe lens opacities that prevented optical biometry, who underwent phacoemulsification (PE) with IOL implantation. IOL power calculation according to the SRK/T formula was based on AL and anterior chamber depth obtained by UBM (Tomey Biometer Al-100) and keratometry on the Topcon KR 8800 autorefractometer. To adapt AL for new generation calculators - Barrett Universal II (BUII), Hill RBF ver. 3.0 (RBF), Kane and Ladas Super Formula (LSF) - the retinal thickness (0.20 mm) was added to the axial length determined by UBM, and then the optical power of the artificial lens was calculated. The mean error and its modulus value were used as criteria for the accuracy of IOL calculation. RESULTS: A significant difference (p=0.008) in the mean IOL calculation error was found between the formulas. Pairwise analysis revealed differences between SRK/T (-0.32±0.58 D) and other formulas - BUII (-0.16±0.52 D; p=0.014), RBF (-0.17±0.51 D; p=0.024), Kane (-0.17±0.52 D; p=0.029), but not with the LSF calculator (-0.19±0.53 D; p=0.071). No significant differences between the formulas were found in terms of mean error modulus (p=0.238). New generation calculators showed a more frequent success in hitting target refraction (within ±1.00 D in more than 95% of cases) than the SRK/T formula (86%). CONCLUSION: The proposed method of adding 0.20 mm to the AL determined by UBM allows using this parameter in modern IOL calculation formulas and improving the refractive results of PE, especially in eyes with non-standard anterior segment structure.


Biometry , Lenses, Intraocular , Phacoemulsification , Refraction, Ocular , Humans , Biometry/methods , Male , Female , Aged , Middle Aged , Reproducibility of Results , Refraction, Ocular/physiology , Phacoemulsification/methods , Axial Length, Eye/diagnostic imaging , Lens Implantation, Intraocular/methods , Cataract/physiopathology , Cataract/diagnosis , Optics and Photonics/methods , Microscopy, Acoustic/methods
4.
Vestn Oftalmol ; 140(2): 40-46, 2024.
Article Ru | MEDLINE | ID: mdl-38742497

Extended depth of focus (EDOF) intraocular lenses (IOLs) are the latest IOL designs. In recent years, several models of EDOF IOLs have become available in Russia, two of which (Tecnis Symfony and Acrysof IQ Vivity) are implanted in our clinic. Comparative studies devoted to the results of implantation of the new EDOF IOLs are rare in the available literature. PURPOSE: This article compares the outcomes of implantation of two EDOF IOLs in patients with presbyopia and/or cataract. MATERIAL AND METHODS: The prospective study included 60 patients (81 eyes) after implantation of EDOF IOL Tecnis Symfony (32 patients, 45 eyes; group 1) or EDOF IOL AcrySof IQ Vivity (28 patients, 36 eyes; group 2). The mean follow-up period was 3.9±1.3 months. RESULTS: All groups showed a significant (p<0.05) increase in uncorrected near visual acuity (UCNVA), intermediate visual acuity (UCIVA), and distance visual acuity (UCDVA) at the maximum follow-up time compared to preoperative values. In group 1, the best corrected near visual acuity (BCNVA) increased from 0.61±0.10 to 0.82±0.16 at the maximum follow-up time, and in group 2 - from 0.58±0.08 to 0.67±0.12 (p>0.05). Both groups showed a significant increase in best corrected intermediate and distance visual acuity (BCIVA and BCDVA) at the maximum follow-up time. The increase in the indicator compared to the preoperative period was not significant in both groups (p>0.05). The frequency of side optical phenomena was low in both groups. No significant differences were found between the groups (p>0.05). CONCLUSION: This study presents a comparative analysis of the results of implantation of two different EDOF IOLs. Both lenses were comparable in most of the studied parameters, including providing good distance and intermediate vision, functional near vision, as well as a low frequency of side optical phenomena. In all cases the patients were satisfied with the results of the surgical intervention.


Lens Implantation, Intraocular , Lenses, Intraocular , Presbyopia , Visual Acuity , Humans , Male , Female , Lens Implantation, Intraocular/methods , Middle Aged , Presbyopia/surgery , Presbyopia/physiopathology , Prosthesis Design , Prospective Studies , Aged , Treatment Outcome , Cataract/physiopathology , Cataract/diagnosis , Refraction, Ocular/physiology , Depth Perception/physiology , Russia
5.
BMC Ophthalmol ; 24(1): 210, 2024 May 13.
Article En | MEDLINE | ID: mdl-38741065

BACKGROUND: Parry-Romberg syndrome (PRS) is a rare progressive degenerative disorder of unknown etiology. Here we report a rare case of PRS combined with lens subluxation in Eye and ENT hospital of Fudan University, Shanghai. To our knowledge, it is the first reported case of PRS combined with lens subluxation that has been managed surgically with phacoemulsification and CTR placement and IOL implantation in Shanghai. CASE PRESENTATION: A 60-year-old woman was referred for "right visual blur for 2 years" and had persistent right facial paralysis of unknown etiology since the age 12. She had right facial muscle atrophy and paralysis. Eye examination also showed the right eyelid pseudoptosis, enophthalmos, age-related cataract combined with lens subluxation existed in the right eye. The patient was diagnosed as age-related cataract and lens subluxation in the right eye and progressive hemifacial atrophy (Parry-Romberg syndrome). We conducted a combined phacoemulsification, IOL and CTR implantation and pupilloplasty surgery for the patient under general anesthesia and the postoperative UCVA was 20/30 and remained for 1 year's follow up. CONCLUSIONS: Here we reported a rare case of PHA combined with lens subluxation in China. After appropriate eye surgery, the patient achieved satisfying vision result in the right eye.


Facial Hemiatrophy , Lens Subluxation , Phacoemulsification , Humans , Female , Facial Hemiatrophy/complications , Facial Hemiatrophy/diagnosis , Facial Hemiatrophy/surgery , Middle Aged , Lens Subluxation/surgery , Lens Subluxation/diagnosis , Lens Subluxation/etiology , Lens Implantation, Intraocular , Visual Acuity/physiology
6.
J Refract Surg ; 40(5): e313-e320, 2024 May.
Article En | MEDLINE | ID: mdl-38717079

PURPOSE: To assess the clinical outcomes and safety profiles of patients who underwent immediate sequential bilateral phakic lens surgery. METHODS: This retrospective multicenter study included 254 consecutive patients (508 eyes) who underwent bilateral same-day Implantable Collamer Lens (ICL) (STAAR Surgical) surgery. The authors focused on 1-year postoperative clinical outcomes and adverse events. RESULTS: In the initial cohort, 176 patients (352 eyes) met inclusion criteria. Of these, 335 eyes underwent myopic ICL placement, and 17 eyes received a hyperopic ICL. Notably, 87% of eyes achieved ±0.50 diopters (D) and 95% achieved ±1.00 D of the intended refraction. One year postoperatively, 78% of eyes demonstrated optimal vaulting (250 to 750 µm), with a significant 19% reduction in vaulting observed over the 12 months (P < .001). Only minor adverse events, including early cataract formation (1 case), secondary toric ICL rotation (3 cases), and ICL exchange due to inappropriate vaulting (6 cases), were noted. CONCLUSIONS: The findings corroborate the safety and efficacy of immediate sequential bilateral phakic lens surgery and indicate its potential as a treatment option. The low incidence of minor adverse events further reinforces its favorable safety profile. [J Refract Surg. 2024;40(5):e313-e320.].


Hyperopia , Lens Implantation, Intraocular , Myopia , Phakic Intraocular Lenses , Refraction, Ocular , Visual Acuity , Humans , Retrospective Studies , Male , Visual Acuity/physiology , Female , Adult , Myopia/surgery , Myopia/physiopathology , Refraction, Ocular/physiology , Hyperopia/surgery , Hyperopia/physiopathology , Young Adult , Treatment Outcome , Middle Aged , Postoperative Complications , Follow-Up Studies , Adolescent
7.
J Refract Surg ; 40(5): e304-e312, 2024 May.
Article En | MEDLINE | ID: mdl-38717085

PURPOSE: To compare intraoperative performance and early postoperative outcomes following phacoemulsification with two systems using active fluidics and one using gravity-based fluidics. METHODS: In this prospective randomized trial, 200 eyes were randomized to the traditional and Active Sentry groups (n = 80 eyes each) where the Centurion Vision System was used with traditional or Active Sentry (Alcon Laboratories, Inc) hand-pieces, respectively, or the Infinit group (n = 40 eyes) where the Infiniti Vision System (Alcon Laboratories, Inc) was used. Within the traditional and Active Sentry groups, there were two subgroups with low (30 mm Hg) or high (55 mm Hg) intraocular pressure (IOP) used. Outcome measures compared were: cumulative dissipated energy (CDE), percentage change in central corneal thickness (CCT) at 1 day, 1 week, and 1 month, anterior chamber cells at 1 day and 1 week, rate of rise and fall of IOP following occlusion break, corneal endothelial cell density (ECD), and macular thickness 6 months postoperatively. RESULTS: CDE was significantly lower in group II compared to the traditional group (2.96 ± 1.4 vs 4.14 ± 2.2, P = .001). With 30 mm Hg IOP, the Active Sentry group had significantly less percentage change in CCT at 1 week postoperatively compared to the traditional handpiece group (0.01% vs 0.02%, P = .008). Incidence of anterior chamber cells less than grade 2 on day 1 was significantly higher in the Active Sentry group (82.9% vs 52%, P = .03). Percentage change in ECD was significantly lower in the Active Sentry group (-0.957 vs -0.98%, P = .005). Significantly faster rise of IOP to baseline following occlusion break was seen in the Active Sentry group. CONCLUSIONS: The use of Active Sentry handpiece was associated with lower CDE, less postoperative increase in CCT, fewer anterior chamber cells, and faster rise of IOP following occlusion break. [J Refract Surg. 2024;40(5):e304-e312.].


Intraocular Pressure , Lens Implantation, Intraocular , Phacoemulsification , Visual Acuity , Humans , Prospective Studies , Intraocular Pressure/physiology , Male , Female , Aged , Visual Acuity/physiology , Middle Aged , Endothelium, Corneal/pathology , Cell Count , Postoperative Period , Tomography, Optical Coherence , Hydrodynamics , Anterior Chamber , Intraoperative Period
8.
BMJ Case Rep ; 17(5)2024 May 22.
Article En | MEDLINE | ID: mdl-38782424

The authors describe a case of reverse pupillary block with pigment dispersion following sequential phakic intraocular lens (pIOL) implantation for high myopia, in a young female patient. The intraocular pressure (IOP) elevation began 3 weeks postoperatively, for which Nd-YAG laser peripheral iridotomies (PIs) were attempted elsewhere. Despite maximum medical therapy, the IOP was uncontrolled. She was referred to our institute for further management. Examination showed anteriorly displaced iris-pIOL diaphragm, iris pigment dispersion and raised IOP. The PIs were incomplete. Based on clinical evaluation and investigations, we concluded that the excess area of contact of the posterior iris over the pIOL caused a reverse pupillary block and pigment dispersion. The IOPs were controlled by repeating laser iridotomies and with medical therapy. Subsequently, the patient developed a low lens vault leading to bilateral cataract. Sequential explantation of the pIOL along with cataract extraction was performed and her vision was restored.


Intraocular Pressure , Lens Implantation, Intraocular , Phakic Intraocular Lenses , Pupil Disorders , Humans , Female , Phakic Intraocular Lenses/adverse effects , Pupil Disorders/etiology , Lens Implantation, Intraocular/adverse effects , Lens Implantation, Intraocular/methods , Adult , Myopia/surgery , Ocular Hypertension/etiology , Postoperative Complications/etiology , Postoperative Complications/surgery , Iris/surgery , Cataract Extraction/adverse effects , Cataract Extraction/methods
9.
Medicine (Baltimore) ; 103(20): e38194, 2024 May 17.
Article En | MEDLINE | ID: mdl-38758875

This study aimed to compare the postimplantation clinical outcomes of 2 types of posterior chamber phakic intraocular lenses (IOLs): Visian™ implantable collamer lenses (ICL; EVO+ V5; Staar Surgical, Monrovia, CA) and an implantable phakic contact lens (IPCL) (IPCL V2.0, Care Group Sight Solution, India) to correct high myopia and myopic astigmatism. This retrospective study included patients who had undergone phakic IOL implantation performed by a single surgeon between March 2021 and March 2022. Preoperative assessments included slit-lamp examination, fundus examination, spherical equivalent, uncorrected distant visual acuity (UDVA), corrected distant visual acuity (CDVA), specular microscope parameters, and optical quality analysis system parameters. Postoperative assessments after 1 year included slit-lamp examination to detect adverse effects and spherical equivalent, UDVA, CDVA, specular microscope, optical quality analysis system, and anterior-segment optical coherence tomography. Eighty eyes from 42 patients (47 eyes from 24 patients in the ICL group and 33 eyes from 18 patients in the IPCL group) were included. No statistically significant differences were observed between the 2 groups regarding preoperative parameters. At 1-year postoperatively, the mean UDVA in the ICL and IPCL groups was 0.019 ±â€…0.040 logMAR and 0.019 ±â€…0.041 logMAR, respectively. The mean CDVA was 0.001 ±â€…0.008 logMAR and 0.001 ±â€…0.007 logMAR in the ICL and IPCL groups, respectively, showing no statistically significant differences. The postoperative parameters did not differ significantly between the 2 groups. The visual acuity and refractive results of both groups were excellent, and both groups exhibited similar efficacy and safety profiles.


Lens Implantation, Intraocular , Phakic Intraocular Lenses , Visual Acuity , Humans , Male , Female , Retrospective Studies , Adult , Lens Implantation, Intraocular/methods , Lens Implantation, Intraocular/adverse effects , Young Adult , Astigmatism/surgery , Myopia/surgery , Treatment Outcome
10.
Curr Opin Ophthalmol ; 35(4): 284-291, 2024 Jul 01.
Article En | MEDLINE | ID: mdl-38700946

PURPOSE OF REVIEW: Higher degrees of myopia are currently being treated with refractive surgery. However, there is limited characterization and outcomes data for this cohort. This article aims to review the literature on highly myopic patients who had refractive surgery and present a retrospective analysis of 149 patients (270 eyes) with high to extreme myopia (≤-5.0D SE) who underwent refractive surgery [laser-assisted subepithelial keratomileusis (LASIK), photorefractive keratectomy (PRK), or implantable collamer lense (ICL)] at a single practice. RECENT FINDINGS: There is substantial literature on the efficacy of LASIK, PRK, and phakic intraocular lenses for refractive error correction, but a dearth of studies on patients with high to extreme myopia undergoing different types of refractive surgery. Our study reveals that this cohort of patients has excellent outcomes with minimal complications. SUMMARY: Our study reveals that the average preoperative myopia was highest in ICL patients (-10.03D), followed by PRK (-7.21D), and LASIK (-7.04D) patients. Not surprisingly, eyes with high myopia and thin corneas were offered and elected ICLs for their procedure. Highly myopic patients achieved outcomes consistent with data reported in the literature- average postoperative uncorrected visual acuity was 20/20 for LASIK and ICL eyes and 20/25 for PRK eyes.


Photorefractive Keratectomy , Visual Acuity , Humans , Visual Acuity/physiology , Treatment Outcome , Photorefractive Keratectomy/methods , Lens Implantation, Intraocular/methods , Keratomileusis, Laser In Situ/methods , Refraction, Ocular/physiology , Retrospective Studies , Myopia, Degenerative/surgery , Myopia, Degenerative/physiopathology , Myopia/surgery , Myopia/physiopathology , Phakic Intraocular Lenses , Adult , Male , Female
11.
Sci Rep ; 14(1): 12558, 2024 May 31.
Article En | MEDLINE | ID: mdl-38822089

This study investigated the underlying causes of the myopic outcomes of the optic-based newer formulas (Barrett Universal II, EVO 2.0, Kane, Hoffer-QST and PEARL-DGS) in long Korean eyes with Alcon TFNT intraocular lens (IOL) implantation. Postoperative data from 3100 randomly selected eyes of 3100 patients were analyzed to compare the reference back-calculated effective lens positions (ELPs) based on the Haigis formula using conventional axial length (AL) and Cooke-modified AL (CMAL) with the predicted ELP of each single- and triple-optimized Haigis formula applied to AL- and CMAL. Contrary to the AL-applied Haigis formula, the predicted ELP curve of the CMAL-applied, single-optimized Haigis formula, simulating the methods of the newer formulas, exhibited a significant upward deviation from the back-calculated ELP in long eyes. The relationship between the AL and anterior chamber depth in our long-eyed population differed from that in the base population of the PEARL-DGS formula. The myopic outcomes in long eyes appeared to stem from the substantial overestimation of the postoperative IOL position with AL modification, leading to the implantation of inappropriately higher-powered IOLs. This discrepancy may be attributed to the ethnic differences in ocular biometrics, particularly the relatively smaller anterior segment in East Asian patients with long AL.


Lens Implantation, Intraocular , Lenses, Intraocular , Myopia , Humans , Myopia/surgery , Male , Female , Middle Aged , Lens Implantation, Intraocular/methods , Republic of Korea , Aged , Refraction, Ocular , Axial Length, Eye/pathology , Biometry/methods , Adult , Visual Acuity , Treatment Outcome , Asian People
12.
Transl Vis Sci Technol ; 13(5): 24, 2024 May 01.
Article En | MEDLINE | ID: mdl-38809530

Purpose: To evaluate the association between preoperative ocular parameters and myopic shift following primary intraocular lens (IOL) implantation in pediatric cataracts. Methods: Eyes from pediatric patients undergoing bilateral cataract surgery with primary IOL implantation were included. Eyes were grouped by age at surgery and subdivided into three axial length (AL) subgroups and three keratometry subgroups. Mixed-effects linear regression was utilized to assess the trend in myopic shift among subgroups. Multivariable analysis was performed to determine factors associated with myopic shift. Results: A total of 222 eyes were included. The median age at surgery was 4.36 years (interquartile range [IQR], 3.16-6.00 years) and the median follow-up was 4.18 years (IQR, 3.48-4.64 years). As preoperative AL increased, a decreased trend was observed in myopic shift and rate of myopic shift (P = 0.008 and P = 0.003, respectively, in the 4 to <6 years old group; P = 0.002 and P < 0.001, respectively, in the ≥6 years old group). Greater myopic shift and rate of myopic shift were associated with younger age at surgery (P = 0.008 and P = 0.008, respectively). Both myopic shift and rate of myopic shift were negatively associated with AL. Conclusions: Age at surgery and preoperative AL were associated with myopic shift in pediatric cataracts following primary IOL implantation. Adjusting the target refraction based on preoperative AL could potentially improve patients' long-term refractive outcome. Translational Relevance: This study may help to guide the selection of postoperative target refraction according to age at surgery and preoperative ocular parameters for pediatric cataracts.


Lens Implantation, Intraocular , Myopia , Humans , Lens Implantation, Intraocular/adverse effects , Female , Myopia/surgery , Myopia/physiopathology , Male , Child, Preschool , Child , Retrospective Studies , Refraction, Ocular/physiology , Axial Length, Eye/pathology , Cataract/complications , Cataract/physiopathology , Cataract Extraction/adverse effects , Visual Acuity/physiology , Preoperative Period , Follow-Up Studies
16.
Turk J Ophthalmol ; 54(2): 63-68, 2024 Apr 19.
Article En | MEDLINE | ID: mdl-38644781

Objectives: To evaluate the clinical results of a new trifocal intraocular lens (IOL) with sinusoidal design by comparing with a traditional trifocal IOL. Materials and Methods: A total of 79 patients undergoing uneventful microincisional cataract surgery with bilateral implantation of one of two types of trifocal IOLs, the Acriva Trinova IOL (VSY) or Acrysof IQ PanOptix IOL (Alcon), were enrolled in this prospective study. Visual and refractive outcomes, contrast sensitivity (CS), and defocus curve were assessed at 3 months after surgery. Patient satisfaction and incidence of photic phenomena were also evaluated. Results: The number of patients/eyes were 48/96 in the Trinova group and 31/62 in the PanOptix group. There were no significant differences between the groups for monocular and binocular corrected/uncorrected distance or intermediate (at 60 cm) and near visual acuities (VA) postoperatively. The Trinova group had statistically significantly better intermediate VA at 80 cm than the PanOptix group (p<0.05). The CS results of both groups were within the normal limits. In the binocular defocus curve of both IOLs, we observed a peak of good VA at 0.0 diopters defocus and a useful wide range for intermediate distances. The incidence of photic phenomena in the Trinova group was lower at postoperative 1 month (p<0.05) but this difference disappeared at 3 months. A total of 47 patients (97.9%) in the Trinova group and 30 patients (96.7%) in the PanOptix group stated that they would recommend the same IOL. Conclusion: Both trifocal IOLs provide good visual quality outcomes and patient satisfaction.


Multifocal Intraocular Lenses , Presbyopia , Prosthesis Design , Refraction, Ocular , Visual Acuity , Humans , Prospective Studies , Female , Male , Visual Acuity/physiology , Aged , Middle Aged , Presbyopia/physiopathology , Presbyopia/surgery , Refraction, Ocular/physiology , Vision, Binocular/physiology , Patient Satisfaction , Contrast Sensitivity/physiology , Phacoemulsification , Follow-Up Studies , Lens Implantation, Intraocular/methods , Lenses, Intraocular
17.
Int Ophthalmol ; 44(1): 198, 2024 Apr 25.
Article En | MEDLINE | ID: mdl-38662107

PURPOSE: Cataract surgery in microphthalmic eyes is challenging due to anatomical restraints, hard bulky nucleus. This series aims to evaluate the safety and efficacy of couching of intraocular lens in irido-fundal coloboma with microphthalmos. SETTING: Tertiary care centre in South India. DESIGN: Retrospective non-comparative study in eyes with irido-fundal coloboma, corneal diameter < 7 mm and brown cataract. Visual acuity less than 6/60 in other eye. METHODS: Anterior chamber entry made, zonules broken and lens dislocated into the vitreous cavity in a controlled manner. Baseline Clinico-demographic details, corrected distance visual acuity (CDVA), Intra-ocular pressure (IOP), corneal diameter, axial length, lens status and post-surgery CDVA, IOP and complications recorded and followed up for atleast 6 months. RESULTS: Fifteen eyes of 15 subjects were evaluated with a mean age 49.4 ± 10.9 years. At baseline, mean IOP 14.5 ± 3.8 mmHg, mean axial length 19.3 ± 0.5 mm, mean corneal diameter was 6.5 ± 0.34 mm and CDVA 2 logMAR which improved to 1.5 logMAR at 3 months (p value 0.002). Transient spike in IOP in 33.3% subjects was medically managed with no significant difference in IOP (p > 0.05) at baseline (14.5 ± 3.8 mmHg), 3 months post-surgery (16 ± 2.8 mmHg) and 6 months post-surgery (14.9 ± 2.5 mmHg). One patient underwent re-couching. No other major complications were noted. CONCLUSION: Couching of cataractous lens is an effective and safe method in microphthalmic eyes with irido-fundal coloboma as last resort procedure, where no other surgical procedure may work. It provides an ambulatory gain of visual acuity in previously non-ambulatory subjects. Corneal measurements help in determining the subset of patients where couching offers viable option.


Cataract , Coloboma , Microphthalmos , Visual Acuity , Humans , Retrospective Studies , Female , Coloboma/diagnosis , Coloboma/complications , Coloboma/surgery , Male , Microphthalmos/complications , Microphthalmos/diagnosis , Microphthalmos/surgery , Cataract/complications , Cataract/congenital , Cataract/diagnosis , Middle Aged , Adult , Iris/surgery , Iris/abnormalities , Lens Implantation, Intraocular/methods , Cataract Extraction/methods , Lens, Crystalline/abnormalities , Lens, Crystalline/surgery , Follow-Up Studies
18.
Sci Rep ; 14(1): 8386, 2024 04 10.
Article En | MEDLINE | ID: mdl-38600286

This prospective, non-randomized, comparative study aimed to compare the visual outcomes and patient satisfaction after implantations of three presbyopia-correcting intraocular lenses (IOLs) after myopic refractive surgery. It was conducted from January 2020 to December 2021 in Shanghai Heping Eye Hospital. Patients were divided into three groups based on the type of IOL implanted. The visual acuity, refractive stability, high-order aberrations, objective visual quality, spectacle independence, and visual function index 14 questionnaire scores of the three groups were compared. This study included 78 eyes of 39 patients: 26 eyes with 839MP, 26 eyes with MF30, and 26 eyes with ZXR00. Uncorrected distance visual acuity improved significantly for all three groups. For a pupil diameter of 4.0 mm, the spherical aberrations of the three groups were 0.33 ± 0.16 µ, 0.50 ± 0.08 µ, and 0.39 ± 0.10 µ, respectively. The spectacle independence for distance vision was over 90% in each group; for near vision, it was only 25% for the ZXR00 group. All three types of presbyopia-correcting IOLs improved visual quality in post-LASIK or PRK patients. However, the high incidence of photic phenomena after presbyopia-correcting IOL implantation in patients who have undergone myopic LASIK should not be neglected.


Lenses, Intraocular , Myopia , Presbyopia , Humans , Presbyopia/surgery , Lens Implantation, Intraocular , Patient Satisfaction , Prospective Studies , China , Myopia/surgery , Prosthesis Design
19.
Zhonghua Yi Xue Za Zhi ; 104(16): 1391-1396, 2024 Apr 23.
Article Zh | MEDLINE | ID: mdl-38644289

Objective: To explore the effects of different types of intraocular lens (IOL) implantation on patient's visual quality and function after phacoemulsification. Methods: The clinical data of patients with monocular cataract who underwent phacoemulsification in the Department of Ophthalmology, People's Hospital Affiliated to Shandong First Medical University between December 2021 and May 2023 were retrospectively analyzed. According to the types of IOL, the patients were divided into monofocal group, bifocal group and depth of focus extension group. Three months later, uncorrected distance visual acuity (UCDVA), best corrected distance visual acuity (BCDVA), uncorrected intermediate visual acuity (UCIVA), best corrected intermediate visual acuity (BCIVA), uncorrected near visual acuity (UCNVA) and best corrected near visual acuity (BCNVA) were detected. Contrast sensitivity and total wavefront aberration were measured by visual function analyzer. Satisfaction with visual quality was evaluated by hospital-made satisfaction questionnaire. Results: A total of 92 patients were included, with 31 males and 61 females, and their age was (61.8±5.2) years. There were 43, 28 and 21 cases in monofocal group, bifocal group and depth of focus extension group, respectively. No statistically significant difference was found in clinical baseline data among the three groups. UCIVA, UCDVA, BCIVA and BCDVA in depth of focus extension group were 1.01±0.13, 0.92±0.18, 1.21±0.19 and 1.20±0.23, respectively, which were higher than those in monofocal group (0.62±0.12, 0.74±0.13, 1.02±0.17, 1.07±0.19, respectively) and bifocal group (0.67±0.15, 0.78±0.14, 1.01±0.16, 1.01±0.18, respectively), while absolute value of spherical equivalent [(-0.42±0.07) D] was lower than that in the other two groups [ (-0.49±0.05) D and (-0.45±0.08) D] (both P<0.05). UCNVA and BCNVA in bifocal group were 0.91±0.18 and 1.25±0.18, which were higher than those in depth of focus extension group (0.63±0.24 and 1.19±0.17) (both P<0.05). There were no significant differences in contrast sensitivity among the three groups under day vision or between monofocal group and bifocal group under night vision (all P>0.05), but the contrast sensitivity was higher in depth of focus extension group under night vision (3.0, 6.0, 12.0 c/d) than other two groups (all P<0.05). The score of ocular discomfort was the highest in bifocal group, followed by depth of focus extension group and monofocal group (both P<0.05). The score of visual interference in bifocal group was lower than that in monofocal group and depth of focus extension group (both P<0.05). The scores of subjective feeling in bifocal group and depth of focus extension group were higher than that in monofocal group (both P<0.05). The reading score was the highest in bifocal group, followed by depth of focus extension group and monofocal group (both P<0.05). There was no significant difference in total low-order aberration among the three groups (P=0.472). The total aberration and higher-order aberration [(0.74±0.35) µm and (0.41±0.12) µm] were the highest in monofocal group, followed by bifocal group [(0.61±0.21) µm and (0.22±0.09) µm] and depth of focus extension group [(0.46±0.13) µm and (0.06±0.09) µm] (all P<0.05). Conclusions: IOL implantation with depth of focus extension can enhance visual range, night vision and contrast sensitivity, and thus effectively improve postoperative visual quality and function in cataract patients. The bifocal IOL can better improve the patient's UCNVA and BCNVA, resulting in high satisfaction with visual quality.


Cataract , Lens Implantation, Intraocular , Lenses, Intraocular , Phacoemulsification , Visual Acuity , Humans , Male , Female , Middle Aged , Retrospective Studies , Contrast Sensitivity , Patient Satisfaction , Surveys and Questionnaires
20.
BMC Ophthalmol ; 24(1): 172, 2024 Apr 16.
Article En | MEDLINE | ID: mdl-38627651

PURPOSE: To assess the efficacy and safety of various intraocular lenses (IOLs), including standard monofocal, bifocal, trifocal, extended depth of focus (EDOF), and enhanced monofocal IOLs, post-cataract surgery through a network meta-analysis. METHODS: A systematic search of PubMed, Cochrane Library, and Web of Science was conducted to identify relevant studies from the past 5 years. Parameters such as binocular visual acuities, spectacle independence, contrast sensitivity (CS), and optical quality were used to evaluate efficacy and safety. Data from the selected studies were analyzed using Review Manager 5.4 and STATA 17.0 software. RESULTS: Twenty-eight Randomized Controlled Trials (RCTs) comprising 2465 subjects were included. Trifocal IOLs exhibited superior uncorrected near visual acuity (UNVA) compared to monofocal IOLs (MD: -0.35; 95% CI: -0.48, -0.22). Both trifocal (AcrySof IQ PanOptix IOLs group MD: -0.13; 95% CI: -0.21, -0.06) and EDOF IOLs (MD: -0.13; 95% CI: -0.17, -0.09) showed better uncorrected intermediate visual acuity (UIVA) than monofocal IOLs. Trifocal IOLs ranked highest in spectacle independence at various distances (AT LISAtri 839MP group: SUCRA 97.5% for distance, 80.7% for intermediate; AcrySof IQ PanOptix group: SUCRA 83.0% for near). CONCLUSIONS: For cataract patients who want to treat presbyopia, trifocal IOLs demonstrated better visual acuity and spectacle independence at near distances. Different types of trifocal IOL characteristics differ. EDOF and enhanced monofocal IOLs have improved visual quality at intermediate distances.Therefore, It is very important to select the appropriate IOLs based on the lens characteristics and patient needs.


Cataract , Lenses, Intraocular , Phacoemulsification , Presbyopia , Humans , Lens Implantation, Intraocular , Presbyopia/surgery , Refraction, Ocular , Patient Satisfaction , Prosthesis Design , Randomized Controlled Trials as Topic
...