Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 6.467
1.
J R Soc Interface ; 21(215): 20240035, 2024 Jun.
Article En | MEDLINE | ID: mdl-38835248

The Earth's magnetic field can provide reliable directional information, allowing migrating animals to orient themselves using a magnetic compass or estimate their position relative to a target using map-based orientation. Here we show for the first time that young, inexperienced herring (Clupea harengus, Ch) have a magnetic compass when they migrate hundreds of kilometres to their feeding grounds. In birds, such as the European robin (Erithacus rubecula), radical pair-based magnetoreception involving cryptochrome 4 (ErCRY4) was demonstrated; the molecular basis of magnetoreception in fish is still elusive. We show that cry4 expression in the eye of herring is upregulated during the migratory season, but not before, indicating a possible use for migration. The amino acid structure of herring ChCRY4 shows four tryptophans and a flavin adenine dinucleotide-binding site, a prerequisite for a magnetic receptor. Using homology modelling, we successfully reconstructed ChCRY4 of herring, DrCRY4 of zebrafish (Danio rerio) and StCRY4 of brown trout (Salmo trutta) and showed that ChCRY4, DrCRY4 and ErCRY4a, but not StCRY4, exhibit very comparable dynamic behaviour. The electron transfer could take place in ChCRY4 in a similar way to ErCRY4a. The combined behavioural, transcriptomic and simulation experiments provide evidence that CRY4 could act as a magnetoreceptor in Atlantic herring.


Cryptochromes , Fishes , Animals , Cryptochromes/metabolism , Cryptochromes/chemistry , Fishes/physiology , Animal Migration/physiology , Magnetic Fields , Fish Proteins/metabolism , Fish Proteins/genetics , Fish Proteins/chemistry , Orientation/physiology
2.
Sci Rep ; 14(1): 12869, 2024 06 04.
Article En | MEDLINE | ID: mdl-38834614

In this work, the effect of moderate electromagnetic fields (2.5, 10, and 15 mT) was studied using an immersed coil inserted directly into a bioreactor on batch cultivation of yeast under both aerobic and anaerobic conditions. Throughout the cultivation, parameters, including CO2 levels, O2 saturation, nitrogen consumption, glucose uptake, ethanol production, and yeast growth (using OD 600 measurements at 1-h intervals), were analysed. The results showed that 10 and 15 mT magnetic fields not only statistically significantly boosted and sped up biomass production (by 38-70%), but also accelerated overall metabolism, accelerating glucose, oxygen, and nitrogen consumption, by 1-2 h. The carbon balance analysis revealed an acceleration in ethanol and glycerol production, albeit with final concentrations by 22-28% lower, with a more pronounced effect in aerobic cultivation. These findings suggest that magnetic fields shift the metabolic balance toward biomass formation rather than ethanol production, showcasing their potential to modulate yeast metabolism. Considering coil heating, opting for the 10 mT magnetic field is preferable due to its lower heat generation. In these terms, we propose that magnetic field can be used as novel tool to increase biomass yield and accelerate yeast metabolism.


Biomass , Ethanol , Fermentation , Magnetic Fields , Saccharomyces cerevisiae , Saccharomyces cerevisiae/metabolism , Saccharomyces cerevisiae/growth & development , Aerobiosis , Anaerobiosis , Ethanol/metabolism , Glucose/metabolism , Bioreactors/microbiology , Glycerol/metabolism , Oxygen/metabolism , Nitrogen/metabolism
3.
PLoS One ; 19(6): e0304279, 2024.
Article En | MEDLINE | ID: mdl-38837968

This paper delves into the intricate relationship between changes in Magnetic inclination and declination at specific geographical locations and the navigational decisions of migratory birds. Leveraging a dataset sourced from a prominent bird path tracking web resource, encompassing six distinct bird species' migratory trajectories, latitudes, longitudes, and observation timestamps, we meticulously analyzed the interplay between these avian movements and corresponding alterations in Magnetic inclination and declination. Employing a circular von Mises distribution assumption for the latitude and longitude distributions within each subdivision, we introduced a pioneering circular-circular regression model, accounting for von Mises error, to scrutinize our hypothesis. Our findings, predominantly supported by hypothesis tests conducted through circular-circular regression analysis, underscore the profound influence of Magnetic inclination and declination shifts on the dynamic adjustments observed in bird migration paths. Moreover, our meticulous examination revealed a consistent adherence to von Mises distribution across all bird directions. Notably, we unearthed compelling correlations between specific bird species, such as the Black Crowned Night Heron and Brown Pelican, exhibiting a noteworthy negative correlation with Magnetic inclination and a contrasting positive correlation with Magnetic declination. Similarly, the Pacific loon demonstrated a distinct negative correlation with Magnetic inclination and a positive association with Magnetic declination. Conversely, other avian counterparts showcased positive correlations with both Magnetic declination and inclination, further elucidating the nuanced dynamics between avian navigation and the Earth's magnetic field parameters.


Animal Migration , Birds , Earth, Planet , Magnetic Fields , Animals , Birds/physiology , Animal Migration/physiology , Spatial Navigation/physiology
5.
J R Soc Interface ; 21(214): 20230745, 2024 May.
Article En | MEDLINE | ID: mdl-38745460

Migratory songbirds may navigate by extracting positional information from the geomagnetic field, potentially with a magnetic-particle-based receptor. Previous studies assessed this hypothesis experimentally by exposing birds to a strong but brief magnetic pulse aimed at remagnetizing the particles and evoking an altered behaviour. Critically, such studies were not ideally designed because they lacked an adequate sham treatment controlling for the induced electric field that is fundamentally associated with a magnetic pulse. Consequently, we designed a sham-controlled magnetic-pulse experiment, with sham and treatment pulse producing a similar induced electric field, while limiting the sham magnetic field to a value that is deemed insufficient to remagnetize particles. We tested this novel approach by pulsing more than 250 wild, migrating European robins (Erithacus rubecula) during two autumn seasons. After pulsing them, five traits of free-flight migratory behaviour were observed, but no effect of the pulse could be found. Notably, one of the traits, the migratory motivation of adults, was significantly affected in only one of the two study years. Considering the problem of reproducing experiments with wild animals, we recommend a multi-year approach encompassing large sample size, blinded design and built-in sham control to obtain future insights into the role of magnetic-particle-based magnetoreception in bird navigation.


Animal Migration , Songbirds , Animals , Songbirds/physiology , Animal Migration/physiology , Magnetic Fields , Flight, Animal/physiology
6.
Biomed Phys Eng Express ; 10(4)2024 May 15.
Article En | MEDLINE | ID: mdl-38701767

Thermoluminescent dosimeters (TLDs) serve as compact and user-friendly tools for various applications, including personal radiation dosimetry and radiation therapy. This study explores the potential of utilizing TLD-100 personal dosimetry, conventionally applied in PET/CT (positron emission tomography/computed tomography) settings, in the PET/MRI (magnetic resonance imaging) environment. The integration of MRI into conventional radiotherapy and PET systems necessitates ionizing radiation dosimetry in the presence of static magnetic fields. In this study, TLD-100 dosimeters were exposed on the surface of a water-filled cylindrical phantom containing PET-radioisotope and positioned on the patient table of a 3 T PET/MRI, where the magnetic field strength is around 0.2 T, aiming to replicate real-world scenarios experienced by personnel in PET/MRI environments. Results indicate that the modified MR-safe TLD-100 personal dosimeters exhibit no significant impact from the static magnetic field of the 3 T PET/MRI, supporting their suitability for personal dosimetry in PET/MRI settings. This study addresses a notable gap in existing literature on the effect of MRI static magnetic field on TLDs.


Magnetic Resonance Imaging , Occupational Exposure , Phantoms, Imaging , Thermoluminescent Dosimetry , Thermoluminescent Dosimetry/methods , Humans , Magnetic Resonance Imaging/methods , Occupational Exposure/analysis , Occupational Exposure/prevention & control , Positron Emission Tomography Computed Tomography/methods , Radiation Dosage , Positron-Emission Tomography/methods , Radiation Monitoring/methods , Magnetic Fields , Radiation Dosimeters
7.
J Chromatogr A ; 1726: 464972, 2024 Jul 05.
Article En | MEDLINE | ID: mdl-38744184

The effect of internal and external magnetic fields on the separation of antifungal drugs by centrifugal acceleration thin-layer chromatography was reported for the first time. External and internal magnetic fields were applied using neodymium magnets and CoFe2O4@SiO2 ferromagnetic nanoparticles. Separation of ketoconazole and clotrimazole was performed using a mobile phase consisting of n-hexane, ethyl acetate, ethanol, and ammonia (2.0:2.0:0.5:0.2, v/v). The influence of the magnetic field on the entire chromatographic system led to changes in the properties of the stationary and mobile phases and the analytes affecting the retention factor, shape, and width of the separated rings. The extent of this impact depended on the structure of the analyte and the type and intensity of the magnetic field. In the presence of the external magnetic field, there were more significant changes in the chromatographic parameters of the drugs, especially the width of the separated rings, and ketoconazole was more affected than clotrimazole. The changes are conceivably due to the effect of the magnetic field on the analyte distribution between the stationary and mobile phases, which is also caused by the possibility of the magnetic field affecting the viscosity, surface tension, and surface free energy between the stationary and mobile phases.


Antifungal Agents , Ketoconazole , Magnetic Fields , Chromatography, Thin Layer/methods , Antifungal Agents/analysis , Antifungal Agents/chemistry , Antifungal Agents/isolation & purification , Ketoconazole/chemistry , Ketoconazole/analysis , Clotrimazole/chemistry , Clotrimazole/analysis , Centrifugation/methods , Silicon Dioxide/chemistry
8.
Arch Microbiol ; 206(6): 273, 2024 May 22.
Article En | MEDLINE | ID: mdl-38772954

Acid protease is widely used in industries such as food processing and feed additives. In the study, low frequency magnetic field (LF-MF) as an aid enhances acid protease production by Aspergillus niger (A. niger). The study assessed mycelial biomass, the enzymic activity of the acidic protease and underlying mechanism. At low intensities, alternating magnetic field (AMF) is more effective than static magnetic fields (SMF). Under optimal magnetic field conditions, acid protease activity and biomass increased by 91.44% and 16.31%, as compared with the control, respectively. Maximum 19.87% increase in enzyme activity after magnetic field treatment of crude enzyme solution in control group. Transcriptomics analyses showed that low frequency alternating magnetic field (LF-AMF) treatment significantly upregulated genes related to hydrolases and cell growth. Our results showed that low-frequency magnetic fields can enhance the acid protease production ability of A. niger, and the effect of AMF is better at low intensities. The results revealed that the effect of magnetic field on the metabolic mechanism of A. niger and provided a reference for magnetic field-assisted fermentation of A. niger.


Aspergillus niger , Magnetic Fields , Peptide Hydrolases , Aspergillus niger/enzymology , Aspergillus niger/genetics , Peptide Hydrolases/metabolism , Peptide Hydrolases/genetics , Fermentation , Fungal Proteins/genetics , Fungal Proteins/metabolism , Biomass , Mycelium/enzymology , Mycelium/growth & development , Mycelium/genetics
9.
Methods Mol Biol ; 2800: 115-145, 2024.
Article En | MEDLINE | ID: mdl-38709482

The actin cortex is an essential element of the cytoskeleton allowing cells to control and modify their shape. It is involved in cell division and migration. However, probing precisely the physical properties of the actin cortex has proved to be challenging: it is a thin and dynamic material, and its location in the cell-directly under the plasma membrane-makes it difficult to study with standard light microscopy and cell mechanics techniques. In this chapter, we present a novel protocol to probe dynamically the thickness of the cortex and its fluctuations using superparamagnetic microbeads in a uniform magnetic field. A bead ingested by the cell and another outside the cell attract each other due to dipolar forces. By tracking their position with nanometer precision, one can measure the thickness of the cortex pinched between two beads and monitor its evolution in time. We first present the set of elements necessary to realize this protocol: a magnetic field generator adapted to a specific imaging setup and the aforementioned superparamagnetic microbeads. Then we detail the different steps of a protocol that can be used on diverse cell types, adherent or not.


Actin Cytoskeleton , Animals , Humans , Actin Cytoskeleton/metabolism , Actin Cytoskeleton/ultrastructure , Actins/metabolism , Magnetic Fields , Microspheres
10.
Anal Chem ; 96(21): 8317-8324, 2024 May 28.
Article En | MEDLINE | ID: mdl-38739544

Nuclear magnetic resonance (NMR) longitudinal rotating frame relaxation time (T1ρ), rarely used in low-field NMR, can be more effective than conventional T1 and T2 relaxation times to differentiate polymorphic forms of solid pharmaceuticals. This could be attributed to T1ρ sensibility to structural and molecular dynamics that can be enhanced by changing the strength of the oscillating magnetic field (B1) of spinlock pulses. Here, we compared the capacity of T1, T2, and T1ρ to differentiate inactive (A) and active (C) crystalline forms of the World Health Organization essential drug Mebendazole. The results showed that T1 and T2 values of both forms were statistically identical at 0.47 T. Conversely, T1ρ of both forms measured with weak spinlock B1 fields, ranging from 0.08 to 0.80 mT were statistically different in the same spectrometer. The T1ρ also has the limit of detection to detect the presence of at least 10% of inactive A form in the active C form. Therefore, T1ρ, measured with weak spinlock B1 fields can be an effective, streamlined, and complementary approach for characterizing not only solid active pharmaceutical ingredients but other solid-state materials as well.


Magnetic Resonance Spectroscopy , Magnetic Resonance Spectroscopy/methods , Mebendazole/chemistry , Pharmaceutical Preparations/chemistry , Pharmaceutical Preparations/analysis , Magnetic Fields , Proof of Concept Study , Bulk Drugs
11.
Biomolecules ; 14(5)2024 Apr 26.
Article En | MEDLINE | ID: mdl-38785928

The combination of magnetic fields and magnetic nanoparticles (MNPs) to kill cancer cells by magneto-mechanical force represents a novel therapy, offering advantages such as non-invasiveness, among others. Pulsed magnetic fields (PMFs) hold promise for application in this therapy due to advantages such as easily adjustable parameters; however, they suffer from the drawback of narrow pulse width. In order to fully exploit the potential of PMFs and MNPs in this therapy, while maximizing therapeutic efficacy within the constraints of the narrow pulse width, a feature-matching theory is proposed, encompassing the matching of three aspects: (1) MNP volume and critical volume of Brownian relaxation, (2) relaxation time and pulse width, and (3) MNP shape and the intermittence of PMF. In the theory, a microsecond-PMF generator was developed, and four kinds of MNPs were selected for in vitro cell experiments. The results demonstrate that the killing rate of the experimental group meeting the requirements of the theory is at least 18% higher than the control group. This validates the accuracy of our theory and provides valuable guidance for the further application of PMFs in this therapy.


Magnetic Fields , Melanoma , Humans , Cell Line, Tumor , Melanoma/pathology , Melanoma/therapy , Cell Survival/drug effects , Magnetite Nanoparticles/chemistry , Magnetite Nanoparticles/therapeutic use
12.
Tomography ; 10(5): 773-788, 2024 May 17.
Article En | MEDLINE | ID: mdl-38787019

Background: The purpose of this study was to investigate the dependence of Intravoxel Incoherent Motion (IVIM) parameters measured in the human calf on B0. Methods: Diffusion-weighted image data of eight healthy volunteers were acquired using five b-values (0-600 s/mm2) at rest and after muscle activation at 0.55 and 7 T. The musculus gastrocnemius mediale (GM, activated) was assessed. The perfusion fraction f and diffusion coefficient D were determined using segmented fits. The dependence on field strength was assessed using Student's t-test for paired samples and the Wilcoxon signed-rank test. A biophysical model built on the three non-exchanging compartments of muscle, venous blood, and arterial blood was used to interpret the data using literature relaxation times. Results: The measured perfusion fraction of the GM was significantly lower at 7 T, both for the baseline measurement and after muscle activation. For 0.55 and 7 T, the mean f values were 7.59% and 3.63% at rest, and 14.03% and 6.92% after activation, respectively. The biophysical model estimations for the mean proton-density-weighted perfusion fraction were 3.37% and 6.50% for the non-activated and activated states, respectively. Conclusions: B0 may have a significant effect on the measured IVIM parameters. The blood relaxation times suggest that 7 T IVIM may be arterial-weighted whereas 0.55 T IVIM may exhibit an approximately equal weighting of arterial and venous blood.


Diffusion Magnetic Resonance Imaging , Muscle, Skeletal , Humans , Diffusion Magnetic Resonance Imaging/methods , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/physiology , Male , Adult , Female , Leg/diagnostic imaging , Leg/blood supply , Magnetic Fields , Motion , Healthy Volunteers , Young Adult
13.
ACS Nano ; 18(20): 13171-13183, 2024 May 21.
Article En | MEDLINE | ID: mdl-38717036

The forefront of micro- and nanorobot research involves the development of smart swimming micromachines emulating the complexity of natural systems, such as the swarming and collective behaviors typically observed in animals and microorganisms, for efficient task execution. This study introduces magnetically controlled microrobots that possess polymeric sequestrant "hands" decorating a magnetic core. Under the influence of external magnetic fields, the functionalized magnetic beads dynamically self-assemble from individual microparticles into well-defined rotating planes of diverse dimensions, allowing modulation of their propulsion speed, and exhibiting a collective motion. These mobile microrobotic swarms can actively capture free-swimming bacteria and dispersed microplastics "on-the-fly", thereby cleaning aquatic environments. Unlike conventional methods, these microrobots can be collected from the complex media and can release the captured contaminants in a second vessel in a controllable manner, that is, using ultrasound, offering a sustainable solution for repeated use in decontamination processes. Additionally, the residual water is subjected to UV irradiation to eliminate any remaining bacteria, providing a comprehensive cleaning solution. In summary, this study shows a swarming microrobot design for water decontamination processes.


Microplastics , Robotics , Microplastics/chemistry , Robotics/instrumentation , Polymers/chemistry , Bacteria/isolation & purification , Water/chemistry , Magnetic Fields , Escherichia coli/isolation & purification , Particle Size
14.
Int J Mol Sci ; 25(10)2024 May 08.
Article En | MEDLINE | ID: mdl-38791149

The crystallization of paramagnetic species in a magnetic field gradient under microgravity-like conditions is an area of interest for both fundamental and applied science. In this paper, a setup for the crystallization of paramagnetic species in the magnetic field up to 7 T generated by a superconducting magnet is described. The research includes calculations of the conditions necessary to compensate for the gravitational force for several types of paramagnetic substances using the magnetic field of superconducting magnets (4.7 T, 7 T, 9.4 T, and 16.4 T). Additionally, for the first time, the crystallization of copper sulfate and cobalt sulfate, as well as a mixture of copper sulfate and cobalt sulfate under gravitational force compensation in a superconducting magnet, was performed. This paper experimentally demonstrates the feasibility of growing paramagnetic crystals within the volume of a test tube on the example of copper and cobalt sulfate crystals. A comparison of crystals grown from the solution of a mixture of copper and cobalt sulfates under the same conditions, with and without the presence of a magnetic field, showed changes in both the number and size of crystals.


Cobalt , Crystallization , Magnetic Fields , Cobalt/chemistry , Weightlessness , Copper Sulfate/chemistry , Copper/chemistry
15.
Bioresour Technol ; 402: 130839, 2024 Jun.
Article En | MEDLINE | ID: mdl-38744396

The performance of an anaerobic ammonium oxidation (anammox) reactor with the magnetic field of 40 mT was systematically investigated. The total nitrogen removal rate was enhanced by 16% compared with that of the control group. The enhancing mechanism was elucidated from the improved mass transfer efficiency, the complicated symbiotic interspecific relationship and the improved levels of functional genes. The magnetic field promoted formation of the loose anammox granular sludge and the homogeneous and well-connected porous structure to enhance the mass transfer. Consequently, Candidatus Brocadia predominated in the sludge with an increase in abundance of 13%. Network analysis showed that the positive interactions between Candidatus Brocadia and heterotrophic bacteria were strengthened, which established a more complicated stable microbial community. Moreover, the magnetic field increased the levels of hdh by 26% and hzs by 35% to promote the nitrogen metabolic process. These results provided novel insights into the magnetic field-enhanced anammox process.


Ammonium Compounds , Bioreactors , Magnetic Fields , Nitrogen , Oxidation-Reduction , Sewage , Anaerobiosis , Sewage/microbiology , Ammonium Compounds/metabolism , Nitrogen/metabolism , Bioreactors/microbiology , Bacteria/metabolism
16.
J Am Chem Soc ; 146(19): 13176-13182, 2024 May 15.
Article En | MEDLINE | ID: mdl-38691505

Synthetic cells can be constructed from diverse molecular components, without the design constraints associated with modifying 'living' biological systems. This can be exploited to generate cells with abiotic components, creating functionalities absent in biology. One example is magnetic responsiveness, the activation and modulation of encapsulated biochemical processes using a magnetic field, which is absent from existing synthetic cell designs. This is a critical oversight, as magnetic fields are uniquely bio-orthogonal, noninvasive, and highly penetrative. Here, we address this by producing artificial magneto-responsive organelles by coupling thermoresponsive membranes with hyperthermic Fe3O4 nanoparticles and embedding them in synthetic cells. Combining these systems enables synthetic cell microreactors to be built using a nested vesicle architecture, which can respond to alternating magnetic fields through in situ enzymatic catalysis. We also demonstrate the modulation of biochemical reactions by using different magnetic field strengths and the potential to tune the system using different lipid compositions. This platform could unlock a wide range of applications for synthetic cells as programmable micromachines in biomedicine and biotechnology.


Artificial Cells , Magnetic Fields , Artificial Cells/chemistry , Artificial Cells/metabolism , Magnetite Nanoparticles/chemistry
17.
Biomed Microdevices ; 26(2): 24, 2024 May 06.
Article En | MEDLINE | ID: mdl-38709370

We report the fabrication and characterisation of magnetic liquid beads with a solid magnetic shell and liquid core using microfluidic techniques. The liquid beads consist of a fluorinated oil core and a polymer shell with magnetite particles. The beads are generated in a flow-focusing polydimethylsiloxane (PDMS) device and cured by photo polymerisation. We investigated the response of the liquid beads to an external magnetic field by characterising their motion towards a permanent magnet. Magnetic sorting of liquid beads in a channel was achieved with 90% efficiency. The results show that the liquid beads can be controlled magnetically and have potential applications in digital microfluidics including nucleic acid amplification, drug delivery, cell culture, sensing, and tissue engineering. The present paper also discusses the magnetophoretic behaviour of the liquid bead by varying its mass and magnetite concentration in the shell. We also demonstrated the two-dimensional self-assembly of magnetic liquid beads for potential use in digital polymerase chain reaction and digital loop mediated isothermal amplification.


Dimethylpolysiloxanes , Dimethylpolysiloxanes/chemistry , Microfluidic Analytical Techniques/instrumentation , Magnetic Fields , Microspheres
19.
Biomed Phys Eng Express ; 10(4)2024 May 10.
Article En | MEDLINE | ID: mdl-38692266

Magnetic nanoparticle hyperthermia (MNPH) has emerged as a promising cancer treatment that complements conventional ionizing radiation and chemotherapy. MNPH involves injecting iron-oxide nanoparticles into the tumor and exposing it to an alternating magnetic field (AMF). Iron oxide nanoparticles produce heat when exposed to radiofrequency AMF due to hysteresis loss. Minimizing the non-specific heating in human tissues caused by exposure to AMF is crucial. A pulse-width-modulated AMF has been shown to minimize eddy-current heating in superficial tissues. This project developed a control strategy based on a simplified mathematical model in MATLAB SIMULINK®to minimize eddy current heating while maintaining a therapeutic temperature in the tumor. A minimum tumor temperature of 43 [°C] is required for at least 30 [min] for effective hyperthermia, while maintaining the surrounding healthy tissues below 39 [°C]. A model predictive control (MPC) algorithm was used to reach the target temperature within approximately 100 [s]. As a constrained MPC approach, a maximum AMF amplitude of 36 [kA/m] and increment of 5 [kA/m/s] were applied. MPC utilized the AMF amplitude as an input and incorporated the open-loop response of the eddy current heating in its dynamic matrix. A conventional proportional integral (PI) controller was implemented and compared with the MPC performance. The results showed that MPC had a faster response (30 [s]) with minimal overshoot (1.4 [%]) than PI controller (115 [s] and 5.7 [%]) response. In addition, the MPC method performed better than the structured PI controller in its ability to handle constraints and changes in process parameters.


Algorithms , Hyperthermia, Induced , Neoplasms , Hyperthermia, Induced/methods , Humans , Neoplasms/therapy , Magnetite Nanoparticles/therapeutic use , Magnetite Nanoparticles/chemistry , Computer Simulation , Magnetic Fields , Models, Theoretical , Temperature , Magnetic Iron Oxide Nanoparticles/chemistry , Models, Biological
20.
Anal Chim Acta ; 1311: 342739, 2024 Jul 04.
Article En | MEDLINE | ID: mdl-38816161

BACKGROUND: Catechol (CC), a prevalent phenolic compound, is a byproduct in various agricultural, chemical, and industrial processes. CC detection is crucial for safeguarding water quality and plays a pivotal role in enhancing the overall quality of life of individuals. Electrochemical biosensors exhibit rapid responses, have small sizes, and can be used for real-time monitoring. Therefore, the development of a fast and sensitive electrochemical biosensor for CC detection is crucial. RESULT: In this study, a laccase-based electrochemical biosensor for detection of CC is successfully developed using Fe3O4 nanoparticles as medium and optimized by applying a magnetic field. This research proposes a unique strategy for biosensor enhancement by actively controlling the distribution of magnetic materials on the electrode surface through the application of a magnetic field, resulting in a visibly alternating stripe pattern. This approach effectively disperses magnetic particles, preventing their aggregation and reducing the boundary layer thickness, enhancing the electrochemical response of the biosensor. After fabrication condition optimization, CC is successfully detected using this biosensor. The fabricated sensor exhibits excellent performance with a wide linear detection range of 10-1000 µM, a low detection limit of 1.25 µM, and a sensitivity of 7.9 µA/mM. The fabricated sensor exhibits good selectivity and reliable detection in real water samples. In addition, the laccase-based sensor has the potential for the fast and accurate monitoring of CC in olive oil. SIGNIFICANCE: The magnetic field optimization in this study significantly improved the performance of the electrochemical biosensor for detecting CC in environmental samples. Overall, the sensor developed in this study has the potential for fast and accurate monitoring of CC in environmental samples, highlighting the potential importance of a magnetic field environment in improving the performance of catechol electrochemical biosensors.


Biosensing Techniques , Catechols , Electrochemical Techniques , Laccase , Catechols/analysis , Catechols/chemistry , Laccase/chemistry , Laccase/metabolism , Magnetic Fields , Magnetite Nanoparticles/chemistry , Electrodes , Surface Properties , Limit of Detection , Enzymes, Immobilized/chemistry , Enzymes, Immobilized/metabolism , Water Pollutants, Chemical/analysis
...