Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 5.822
Filter
1.
BMC Oral Health ; 24(1): 758, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38956625

ABSTRACT

BACKGROUND: The intrusion of maxillary anterior teeth is often required and there are various intrusion modes with mini-implants in clear aligner treatment. The objective of this study was to evaluate the effectiveness of maxillary anterior teeth intrusion with different intrusion modes, aiming to provide references for precise and safe intrusion movements in clinical practice. METHODS: Cone-beam computed tomography and intraoral optical scanning data of a patient were collected. Finite element models of the maxilla, maxillary dentition, periodontal ligaments (PDLs), clear aligner (CA), attachments, and mini-implants were established. Different intrusion modes of the maxillary anterior teeth were simulated by changing the mini-implant site (between central incisors, between central and lateral incisor, between lateral incisor and canine), loading site (between central incisors, on central incisor, between central and lateral incisor, between lateral incisor and canine), and loading mode (labial loading and labiolingual loading). Ten conditions were generated and intrusive forces of 100 g were applied totally. Then displacement tendency of the maxillary anterior teeth and CA, and stress of the PDLs were analyzed. RESULTS: For the central incisor under condition L14 and for the canine under conditions L11, L13, L23, and L33, the intrusion amount was negative. Under other conditions, the intrusion amount was positive. The labiolingual angulation of maxillary anterior teeth exhibited positive changes under all conditions, with greater changes under linguoincisal loading. The mesiodistal angulation of canine exhibited positive changes under labial loading, while negative changes under linguoincisal loading except for condition L14. CONCLUSIONS: The intrusion amount, labiolingual and mesiodistal angulations of the maxillary anterior teeth were affected by the mini-implant site, loading site, and loading mode. Labial and linguoincisal loading may have opposite effects on the intrusion amount of maxillary anterior teeth and the mesiodistal angulation of canine. The labiolingual angulation of the maxillary incisors would increase under all intrusion modes, with greater increases under linguoincisal loading.


Subject(s)
Cone-Beam Computed Tomography , Dental Implants , Finite Element Analysis , Incisor , Maxilla , Orthodontic Anchorage Procedures , Periodontal Ligament , Tooth Movement Techniques , Humans , Tooth Movement Techniques/methods , Tooth Movement Techniques/instrumentation , Orthodontic Anchorage Procedures/instrumentation , Orthodontic Anchorage Procedures/methods , Periodontal Ligament/diagnostic imaging , Imaging, Three-Dimensional/methods , Cuspid/diagnostic imaging , Orthodontic Appliance Design , Dental Stress Analysis , Biomechanical Phenomena , Orthodontic Appliances, Removable
2.
Medicine (Baltimore) ; 103(27): e38742, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38968482

ABSTRACT

In orthodontic treatment of patients during the mixed dentition period, arch expansion and opening deep overbite are one of the objectives to achieve proper alignment of the teeth and correction of sagittal and vertical discrepancies. However, the expected outcomes of most therapeutic regimens are not clear, making it impossible to standardize early treatment effects. Therefore, this study was designed to evaluate the impact of the Invisalign® First System on the dental arch circumference and incisor inclination in patients during the mixed dentition period. A total of 21 children during the mixed dentition period (10 females and 11 males, with an average age of 8.76 years) were included in this study. The patients received non-extraction treatment through Invisalign® First System clear aligners, and no other auxiliary devices were used except Invisalign® accessories. Subsequently, the cooperation degree of patients during treatment and the oral measurement parameters at the beginning (T1) and the end (T2) of treatment were collected. All patients showed moderate/good cooperation degree during treatment. Besides, horizontal width of the maxillary first molar increased significantly; the designed arch expansion was 4.1 mm (±1.4 mm), while the actual arch expansion was 3.0 mm (±1.7 mm). Furthermore, the torque expression rate of upper anterior teeth reached 56.53%. Invisalign® First System clear aligners can effectively correct the teeth of patients during the mixed dentition period, widen the circumference of dental arch, and control the torque of incisors.


Subject(s)
Dentition, Mixed , Incisor , Malocclusion , Molar , Torque , Humans , Male , Female , Child , Malocclusion/therapy , Orthodontic Appliances, Removable , Dental Arch , Orthodontic Appliance Design , Tooth Movement Techniques/instrumentation , Tooth Movement Techniques/methods
3.
Prog Orthod ; 25(1): 27, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38972901

ABSTRACT

BACKGROUND: The acceptability and preference for clear aligner therapy (CAT) has been increasing among orthodontists, but there is still a lack of consensus regarding CAT best practices. Consequently, this study aimed to investigate CAT practices among orthodontists practicing in Canada. METHODS: The survey was conducted among orthodontists practicing in Canada using a modified previously published survey. Sixty orthodontists participated (6.1% response rate). It consisted of 11 sections with open and closed questions related to demographic information and particularities about using or not using CAT. The survey responses were exported from REDCap to a Microsoft Excel (Microsoft, Redmond, Wash) spreadsheet, then statistically analyzed using SPSS software (SPSS for Windows, version 21.0; IBM Inc., Armonk, NY, USA). The comments were categorized under themes and subthemes. Data were organized in descriptive statistics, expressing frequencies and percentages. RESULTS: Almost 30% of the orthodontist's annual caseload was treated with CAT, most frequently prescribed to adult patients. Case complexity and patient cooperation were the factors that most influenced the decision to prescribe CAT. Almost half of orthodontists reported sometimes combining CAT with adjunctive fixed appliances. CONCLUSIONS: Most orthodontists prescribe CAT, and its use is based on the malocclusion's complexity. Orthodontists who do not prescribe CAT believe that fixed appliance therapy has superior treatment outcomes.


Subject(s)
Orthodontists , Practice Patterns, Dentists' , Humans , Canada , Orthodontists/statistics & numerical data , Practice Patterns, Dentists'/statistics & numerical data , Surveys and Questionnaires , Male , Adult , Female , Malocclusion/therapy , Orthodontic Appliance Design
4.
Eur J Orthod ; 46(4)2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39011819

ABSTRACT

BACKGROUND: Extraction space closure is a challenging phase during orthodontic treatment that affects not only the total treatment duration but also the whole treatment outcome. OBJECTIVE: To compare the efficiency of friction and frictionless mechanics during en-masse retraction of maxillary anterior teeth in adult patients with bimaxillary dentoalveolar protrusion. TRIAL DESIGN: Two-arm parallel group, single-center randomized clinical trial. MATERIALS AND METHODS: Thirty-two adult patients with bimaxillary protrusion were recruited and randomly allocated to two different retraction mechanics. A friction group, using NiTi coil springs and a frictionless group using closing T-loops for en-masse retraction. Randomization in a 1:1 ratio was generated by Microsoft Excel. The randomization numbers were secured in opaque sealed envelopes for allocation concealment. Retraction started in all patients following first premolars extraction using miniscrews as a source of indirect anchorage. Activation was done on a monthly basis until complete retraction of anterior segment. The rate of retraction, amount of anchorage loss, the dental, and soft tissue changes were analyzed on digital models and lateral cephalograms taken before retraction and after space closure. BLINDING: The outcome assessor was blinded through data concealment during assessment. RESULTS: Two patients were lost to follow up, so 30 patients completed the trial. The rate of anterior segment retraction was 0.88 ±â€…0.66 mm/month in the frictionless group compared to 0.72 ±â€…0.36 mm/month in the friction group which was statistically significant. Anchorage loss of 1.18 ±â€…0.72 mm in the friction group compared to 1.29 ±â€…0.55 mm in the frictionless group with no significant difference. Comparable dental and soft tissue changes following en-masse retraction were reported in both groups, with no statistically significant difference. HARM: one patient complained of soft tissue swelling following miniscrew insertion, but the swelling disappeared after one week of using mouth wash. LIMITATION: The study focused only on the maxillary arch. CONCLUSION: Both mechanics have successfully achieved the required treatment objectives in patients with bimaxillary dentoalveolar protrusion. Frictionless group showed a faster rate of retraction than the friction group, which was statistically but not clinically significant. TRIAL REGISTRATION: Clinicaltrials.gov with the identifier NCT03261024.


Subject(s)
Friction , Maxilla , Tooth Movement Techniques , Humans , Male , Female , Adult , Tooth Movement Techniques/methods , Tooth Movement Techniques/instrumentation , Young Adult , Orthodontic Space Closure/methods , Orthodontic Space Closure/instrumentation , Orthodontic Anchorage Procedures/instrumentation , Orthodontic Anchorage Procedures/methods , Malocclusion, Angle Class I/therapy , Malocclusion, Angle Class I/physiopathology , Orthodontic Appliance Design , Orthodontic Wires , Cephalometry/methods , Treatment Outcome , Nickel , Titanium
5.
Eur J Orthod ; 46(4)2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39011818

ABSTRACT

BACKGROUND: While retention appliances are widely used in orthodontics, there is still no evidence-based consensus regarding the optimal type of appliance or time of retention. OBJECTIVES: To compare chairside rectangular chain retainers, which can be placed in one sitting, with conventional multi-stranded bonded retainers regarding their levels of stability, biological side effects, complications, and patient experiences. TRIAL DESIGN: A single-centre, two-arm, parallel-group randomized controlled trial. METHODS: In total, 48 patients were included in this single-centre, randomized controlled trial conducted in Varberg, Region Halland, Sweden. The patients were randomized to two groups: the chairside rectangular chain retainer group, using the Ortho FlexTech retainer (OFT); and the conventional retainer group, using the 0.0195 Penta One multi-stranded spiral wire (PeO). The primary outcome was Little´s irregularity index (LII) evaluated at debond (T0) and at 3 months (T3) and 12 months (T12). The secondary outcomes were inter-canine distance (ICD), plaque index (PI), calculus index (CI), bleeding on probing (BoP), and caries, evaluated at T0, T3, and T12, as well as patients' perceptions, evaluated at T3 and T12, and technical complications that were registered throughout the study period. The Mann-Whitney U-test was used for continuous variables for inter-group comparisons, and the Wilcoxon Signed Rank test was used for intra-group comparisons. RESULTS: There were no statistically significant differences between the groups regarding LII, biological side effects, technical complications, or patients' experiences. However, there was a small but statistically significant difference between the groups regarding the maintenance of the ICD. Within the OFT group, there was a significant increase in CI, and within the PeO group, there was a significant increase in BoP. CONCLUSIONS: In terms of clinical relevance, the chairside rectangular chain retainer and the conventional multi-stranded spiral wire provide similar outcomes with respect to the stability of alignment, biological side-effects, technical complications, and patients' experiences short-term. TRIAL REGISTRATION: VGFOUreg-929962. Keywords: Orthodontic retainers; fixed retainers; retention; stability.


Subject(s)
Orthodontic Appliance Design , Orthodontic Retainers , Humans , Male , Female , Adolescent , Young Adult , Adult , Dental Plaque Index , Orthodontic Wires , Malocclusion/therapy
6.
Dental Press J Orthod ; 29(3): e2423159, 2024.
Article in English | MEDLINE | ID: mdl-38985075

ABSTRACT

INTRODUCTION: Extraction vs. non-extraction is a crucial decision in orthodontic therapy. OBJECTIVE: The aim of the present study was to investigate the changes in the dental arch width and buccal corridor after orthodontic treatment using extraction and non-extraction therapy with Damon self-ligating system. MATERIAL AND METHODS: This retrospective study consisted of 35 patients (20 female and 15 male patients with median age of 12.5 years), treated by extracting 4 or 2 premolars, and 37 patients (16 female and 21 male patients with the median age of 12.8 years), treated without premolar extraction. Both groups were treated with Damon self-ligating system. Plaster models before (T0) and after (T1) treatment were measured, and the arch width values were determined at the level of the first molars, second premolars, canines and palatal rugae. Buccal corridor width was measured using the extraoral images at T0 and T1. Paired t-test was used for the analysis of the normally distributed data, and Wilcoxon Mann-Whitney U test was used for the data with non-normal distribution. Values of p<0.05 were set as statistically significant. RESULTS: The upper intercanine width increased significantly in both groups (p<0.01). In the non-extraction group, the arch width increased significantly in the maxillary second premolar and first molar region (p<0.01) as well as in the region of the canines (p=0.04), second premolars (p=0.01) and first molars (p<0.01) of the mandible. The buccal corridor decreased significantly in the non-extraction group (p<0.01). CONCLUSION: Premolar extraction in combination with Damon self-ligating system did not lead to reduction of the dental arch width in the maxilla, nor did it increase the size of the buccal corridors.


Subject(s)
Bicuspid , Dental Arch , Models, Dental , Tooth Extraction , Humans , Dental Arch/anatomy & histology , Male , Bicuspid/surgery , Female , Retrospective Studies , Child , Adolescent , Orthodontic Appliance Design , Cephalometry , Molar , Orthodontic Brackets , Cuspid , Orthodontics, Corrective/methods , Tooth Movement Techniques/methods , Tooth Movement Techniques/instrumentation , Orthodontic Appliances, Fixed
7.
Dental Press J Orthod ; 29(3): e2423277, 2024.
Article in English | MEDLINE | ID: mdl-38985077

ABSTRACT

OBJECTIVE: This study aimed to compare the influence of four different maxillary removable orthodontic retainers on speech. MATERIAL AND METHODS: Eligibility criteria for sample selection were: 20-40-year subjects with acceptable occlusion, native speakers of Portuguese. The volunteers (n=21) were divided in four groups randomized with a 1:1:1:1 allocation ratio. The four groups used, in random order, the four types of retainers full-time for 21 days each, with a washout period of 7-days. The removable maxillary retainers were: conventional wraparound, wraparound with an anterior hole, U-shaped wraparound, and thermoplastic retainer. Three volunteers were excluded. The final sample comprised 18 subjects (11 male; 7 female) with mean age of 27.08 years (SD=4.65). The speech evaluation was performed in vocal excerpts recordings made before, immediately after, and 21 days after the installation of each retainer, with auditory-perceptual and acoustic analysis of formant frequencies F1 and F2 of the vowels. Repeated measures ANOVA and Friedman with Tukey tests were used for statistical comparison. RESULTS: Speech changes increased immediately after conventional wraparound and thermoplastic retainer installation, and reduced after 21 days, but not to normal levels. However, this increase was statistically significant only for the wraparound with anterior hole and the thermoplastic retainer. Formant frequencies of vowels were altered at initial time, and the changes remained in conventional, U-shaped and thermoplastic appliances after three weeks. CONCLUSIONS: The thermoplastic retainer was more harmful to the speech than wraparound appliances. The conventional and U-shaped retainers interfered less in speech. The three-week period was not sufficient for speech adaptation.


Subject(s)
Cross-Over Studies , Orthodontic Retainers , Humans , Female , Male , Adult , Orthodontic Appliance Design , Young Adult , Speech/physiology
8.
Dental Press J Orthod ; 29(2): e2423212, 2024.
Article in English | MEDLINE | ID: mdl-38865514

ABSTRACT

OBJECTIVE: The purpose of this retrospective study was to compare accuracy of arch expansion using two different thermoplastic materials in Invisalign aligners: EX30® (Polyethylene Terephthalate Glycol, or PETG) and SmartTrack® (polyurethane). METHODS: The study sample comprised 65 adult patients consecutively treated with Invisalign from two private practices: group 1 - treated with EX30® (358 teeth) and group 2 - treated with SmartTrack® (888 teeth). Six hundred and twenty-three measurements were assessed in three digital models throughout treatment: model 1 - initial, model 2 - predicted tooth position, and model 3 - achieved position. Sixteen reference points per arch were marked and, after best alignment, 2 points per tooth were copied from one digital model to another. Linear values of both arches were measured for canines, premolars, and first molars: on lingual gingival margins and cusp tips of every tooth. Comparisons were performed by Wilcoxon and Mann-Whitney test. RESULTS: Both termoplastic materials presented significant differences between predicted and achieved values for all measurements, except for the lower molar cusp tip in the SmartTrack® group. There is no statistical difference in the accuracy of transverse expansion between these two materials. Overall accuracy for EX30® aligners in maxilla and mandible were found to be 37 and 38%, respectively; and Smarttrack® presented an overall accuracy of 56.62% in the maxilla and 68.72% in the mandible. CONCLUSIONS: It is not possible to affirm one material expands better than the other. Further controlled clinical studies should be conducted comparing SmartTrack® and EX30® under similar conditions.


Subject(s)
Orthodontic Appliance Design , Polyethylene Terephthalates , Polyurethanes , Tooth Movement Techniques , Humans , Retrospective Studies , Adult , Female , Tooth Movement Techniques/instrumentation , Male , Polyurethanes/therapeutic use , Polyethylene Glycols , Dental Arch , Orthodontic Appliances, Removable , Young Adult
9.
Dental Press J Orthod ; 29(2): e2423253, 2024.
Article in English | MEDLINE | ID: mdl-38865515

ABSTRACT

OBJECTIVE: To assess the effectiveness of a customized distalizer with Variety SP® screws anchored on palatal miniscrews for upper molar distalization. METHODS: Seventeen patients aged between 12.5 and 24 years underwent distalization with a customized distalizer. Lateral cephalogram and cast analysis were performed before and after distalization. Linear and angular parameters of the upper first molar, first premolar, and central incisor were assessed. RESULTS: Distalization with the force passing near the center of resistance (CRes) of the upper first molars resulted in distal movement, with minimal distal tipping (2.8 ±â€Š0.45°, p< 0.05). However, distalization passing occlusal to the CRes led to greater distal tipping (13.6 ±â€Š1.63°, p< 0.05). Statistically significant spontaneous distal tipping and distal movement of the upper first premolars occurred, with a mean of 6.2 ±â€Š1.24° (p< 0.05) and 0.68 ±â€Š0.34 mm (p< 0.05), respectively. The positional change of the upper central incisors presented a mean of -0.23 ±â€Š0.1 mm (p> 0.05) and 2.65 ±â€Š1.1° (p< 0.05). Upper first molar intrusion was statistically significant, with a mean of 0.88 ±â€Š0.2 mm (p< 0.05). Upper right and left first molars rotation towards palatal midline presented mean of 4.1 ±â€Š0.19° (p< 0.05) and 3.4  ±â€Š0.1° (p< 0.05), respectively. Additionally, the distance between upper right and left first molars increased significantly, with a mean of 2.54 ±â€Š0.01 mm (p< 0.05). CONCLUSION: The study successfully demonstrated the efficiency of molar distalization without anchorage loss using a customized distalizer anchored on palatal miniscrews.


Subject(s)
Bone Screws , Cephalometry , Molar , Orthodontic Anchorage Procedures , Orthodontic Appliance Design , Tooth Movement Techniques , Humans , Tooth Movement Techniques/instrumentation , Tooth Movement Techniques/methods , Orthodontic Anchorage Procedures/instrumentation , Orthodontic Anchorage Procedures/methods , Adolescent , Child , Young Adult , Female , Male , Maxilla/surgery , Bicuspid , Incisor , Models, Dental
10.
BMC Oral Health ; 24(1): 694, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38879479

ABSTRACT

BACKGROUND: to evaluate the predictability of expansion achieved in patients in early mixed dentition treated with Clear Aligners (CA), analyzing the efficiency of the expansion at the end of the first set of aligners and at the end of the therapy in the upper and lower arch. METHODS: 36 patients (20 F, 16 M; mean age 8.3 ± 1.5 years) were selected retrospectively from the Department of Orthodontics of the Hospital of Rome "Tor Vergata". All subjects were treated with CA with no other auxiliaries than attachments. For each patient a standardized sequential expansion protocol was planned for both arches. Digital dental casts were created at three observation periods from an intraoral scanner: prior to treatment (T0), at the end of the first set of aligners (T1), at the end of treatment (T2). The 3D models in planned position determined by the first Clincheck (CC) were obtained for comparison with T1 and T2. Six linear transversal measurements were used to evaluate the dimensional changes and the predictability of expansion movements, comparing T1-CC and T2-CC. RESULTS: a statistically significant increase within the pre-treatment and the final outcomes for all the variables examined was found. In the upper arch, the greatest level of predictability was detected at the level of the first (46.44%) and second deciduous molar width (44.95%) at T1. The analysis of T2-CC changes showed a significant increase in the percentage of predictability of expansion at the level of the first permanent molars, at mesial (54.86%) and distal (58.92%) width. In the lower arch, a higher percentage of predictability than the upper arch was reported at T1-CC and T2-CC, with the greatest values at the level of second (T1-CC: 48.70%; T2-CC: 75.32%) and first deciduous molar width (T1-CC: 45.71%; T2-CC: 72.75%). CONCLUSIONS: CA can induce significant transversal increments. The predictability of expansion is variable, but it did not exceed the 50% during the first set of aligners. It was necessary to apply refinement set to achieve a good predictability for expansion of about 70%. The expansion in the lower arch was observed to be more predictable than in the upper arch.


Subject(s)
Dental Arch , Dentition, Mixed , Models, Dental , Palatal Expansion Technique , Humans , Retrospective Studies , Female , Child , Male , Dental Arch/anatomy & histology , Palatal Expansion Technique/instrumentation , Orthodontic Appliance Design , Imaging, Three-Dimensional/methods , Tooth Movement Techniques/instrumentation , Tooth Movement Techniques/methods , Maxilla/anatomy & histology , Mandible/anatomy & histology , Orthodontic Appliances, Removable , Forecasting , Cephalometry/methods , Malocclusion/therapy , Treatment Outcome
11.
Sci Rep ; 14(1): 14877, 2024 06 27.
Article in English | MEDLINE | ID: mdl-38937650

ABSTRACT

The composite attachment loss during orthodontic clear aligner therapy is an adverse event that commonly happens in clinical practice and can affect the overall outcome and length of treatment. The aim of our research is to provide a basis for the further study of an innovative digital protocol and application method for orthodontic aligner attachments. Two 3D models were designed, one based on the proposed protocol and the other on the conventional method for aligner attachment application. Four attachment shapes were used to identify the maximum values for the von Mises equivalent stresses, the maximum displacements values and the areas in which these values were recorded through FEM analysis. The results of the mechanical simulation show lower values of von Mises stress recorded in the 3D printed attachments assemblies, independent of their shape, when simulated under the same boundary and load conditions. The trapezoidal prism shaped 3D printed model has a 3.7 times smaller displacement value (0.088 [mm]) compared to the adhesive resin model (0.326 [mm]). In conclusion, the proposed protocol for aligner attachments and the introduction of innovative materials is a promising method of solving conventional attachment problems in current orthodontic treatments.


Subject(s)
Finite Element Analysis , Printing, Three-Dimensional , Humans , Stress, Mechanical , Tooth Movement Techniques/instrumentation , Tooth Movement Techniques/methods , Orthodontic Appliance Design
12.
Dent Clin North Am ; 68(3): 495-515, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38879283

ABSTRACT

The use of mandibular repositioning devices (MRDs) in the management of patients with obstructive sleep apnea (OSA) has gained extensive recognition with relevant clinical evidence of its effectiveness. MRDs are designed to advance and hold the mandible in a protrusive position to widen the upper airway and promote air circulation. This review of the MRD aims to provide an evidence-based update on the optimal design features of an MRD, an analysis of the variety of appliances available, and the current understanding of the action mechanism.


Subject(s)
Mandibular Advancement , Sleep Apnea, Obstructive , Humans , Sleep Apnea, Obstructive/therapy , Mandibular Advancement/instrumentation , Orthodontic Appliance Design
13.
J Dent ; 147: 105108, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38844153

ABSTRACT

OBJECTIVES: This study aimed to propose a standardized protocol for the fabrication of three-dimensionally (3D)-printed curvature-adaptive splints (CASs) and assess the precision of CASs on dentitions with different depths of the curve of Spee (COS). METHODS: 76 lower dental resin models, each exhibiting one of the four types of COS (0-, 2-, 4-, and 6-mm deep), were selected and digitally scanned. CASs were designed, 3D printed, and grouped into C0, C2, C4, and C6, corresponding to the four types of COS depths. To assess precision, the CASs occluded with the resin model were scanned as a whole and compared with the originally designed ones. RESULTS: In terms of translational deviations observed in the CASs, the mean value of absolute sagittal deviation (0.136 mm) was significantly higher than those of vertical (0.091 mm) and transversal deviations (0.045 mm) (P < 0.01). Regarding rotational deviations of the CASs, the mean deviation in pitch (0.323°) was significantly higher than those in yaw (0.083°) and roll (0.110°) (P < 0.01). However, when comparing the accuracy of CASs across C0, C2, C4, and C6 groups, no statistically significant difference was found. Additionally, the translational deviations, rotational deviations, and RMSE of all groups were significantly lower than the clinically acceptable limits of 0.5 mm, 1°, and 0.25 mm, respectively (P < 0.01). CONCLUSIONS: The depth of the COS has no significant impact on the precision of CASs, as evidenced by the absence of statistically significant differences in translational, rotational deviations, and RMSE among all groups (C0, C2, C4, and C6). Moreover, despite relatively high deviations in the sagittal dimension and pitch, all dimensional deviations and RMSE remained statistically significantly lower than the corresponding clinically acceptable limits (CALs) in all groups. CLINICAL SIGNIFICANCE: This standardized protocol incorporating "curvature-adaptation" represents an optimized approach to fabricating diverse 3D-printed splints tailored to dentitions with different anatomical features in contemporary digital dentistry.


Subject(s)
Models, Dental , Printing, Three-Dimensional , Humans , Computer-Aided Design , Rotation , Orthodontic Appliance Design
14.
Sci Rep ; 14(1): 13203, 2024 06 08.
Article in English | MEDLINE | ID: mdl-38851833

ABSTRACT

This study aims to refine clinical designs within clear aligner therapy, exploring the appropriate ratio of anterior tooth retraction to intrusion under maximum anchorage. Using a three-dimensional finite element model and evaluating 19 load scenarios with first premolar extraction, the research identifies the optimal force angle for anterior tooth retraction as 45 to 55°. For clinical planning, it is recommended to design a retraction of 0.19 mm combined with an intrusion of 0.16 mm to achieve anterior tooth retraction. This investigation is crucial for enhancing understanding of biomechanical principles in clear aligner orthodontics, offering significant insights for effective treatments.


Subject(s)
Finite Element Analysis , Tooth Movement Techniques , Humans , Tooth Movement Techniques/methods , Biomechanical Phenomena , Bicuspid/physiology , Orthodontic Appliance Design , Imaging, Three-Dimensional
SELECTION OF CITATIONS
SEARCH DETAIL