Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 54.605
1.
Crit Care ; 28(1): 187, 2024 05 30.
Article En | MEDLINE | ID: mdl-38816883

BACKGROUND: Although several trials were conducted to optimize the oxygenation range in intensive care unit (ICU) patients, no studies have yet reached a universal recommendation on the optimal a partial pressure of oxygen in arterial blood (PaO2) range in patients with sepsis. Our aim was to evaluate whether a relatively high arterial oxygen tension is associated with longer survival in sepsis patients compared with conservative arterial oxygen tension. METHODS: From the Korean Sepsis Alliance nationwide registry, patients treated with liberal PaO2 (PaO2 ≥ 80 mm Hg) were 1:1 matched with those treated with conservative PaO2 (PaO2 < 80 mm Hg) over the first three days after ICU admission according to the propensity score. The primary outcome was 28-day mortality. RESULTS: The median values of PaO2 over the first three ICU days in 1211 liberal and 1211 conservative PaO2 groups were, respectively, 107.2 (92.0-134.0) and 84.4 (71.2-112.0) in day 1110.0 (93.4-132.0) and 80.0 (71.0-100.0) in day 2, and 106.0 (91.9-127.4) and 78.0 (69.0-94.5) in day 3 (all p-values < 0.001). The liberal PaO2 group showed a lower likelihood of death at day 28 (14.9%; hazard ratio [HR], 0.79; 95% confidence interval [CI] 0.65-0.96; p-value = 0.017). ICU (HR, 0.80; 95% CI 0.67-0.96; p-value = 0.019) and hospital mortalities (HR, 0.84; 95% CI 0.73-0.97; p-value = 0.020) were lower in the liberal PaO2 group. On ICU days 2 (p-value = 0.007) and 3 (p-value < 0.001), but not ICU day 1, hyperoxia was associated with better prognosis compared with conservative oxygenation., with the lowest 28-day mortality, especially at PaO2 of around 100 mm Hg. CONCLUSIONS: In critically ill patients with sepsis, higher PaO2 (≥ 80 mm Hg) during the first three ICU days was associated with a lower 28-day mortality compared with conservative PaO2.


Critical Illness , Intensive Care Units , Oxygen , Sepsis , Humans , Male , Female , Middle Aged , Critical Illness/mortality , Critical Illness/therapy , Aged , Sepsis/mortality , Sepsis/blood , Sepsis/therapy , Republic of Korea/epidemiology , Cohort Studies , Oxygen/blood , Intensive Care Units/organization & administration , Intensive Care Units/statistics & numerical data , Partial Pressure , Registries/statistics & numerical data , Hospital Mortality , Blood Gas Analysis/methods , Blood Gas Analysis/statistics & numerical data
2.
Proc Natl Acad Sci U S A ; 121(22): e2316117121, 2024 May 28.
Article En | MEDLINE | ID: mdl-38776372

We report the reliable detection of reproducible patterns of blood-oxygenation-level-dependent (BOLD) MRI signals within the white matter (WM) of the spinal cord during a task and in a resting state. Previous functional MRI studies have shown that BOLD signals are robustly detectable not only in gray matter (GM) in the brain but also in cerebral WM as well as the GM within the spinal cord, but similar signals in WM of the spinal cord have been overlooked. In this study, we detected BOLD signals in the WM of the spinal cord in squirrel monkeys and studied their relationships with the locations and functions of ascending and descending WM tracts. Tactile sensory stimulus -evoked BOLD signal changes were detected in the ascending tracts of the spinal cord using a general-linear model. Power spectral analysis confirmed that the amplitude at the fundamental frequency of the response to a periodic stimulus was significantly higher in the ascending tracts than the descending ones. Independent component analysis of resting-state signals identified coherent fluctuations from eight WM hubs which correspond closely to the known anatomical locations of the major WM tracts. Resting-state analyses showed that the WM hubs exhibited correlated signal fluctuations across spinal cord segments in reproducible patterns that correspond well with the known neurobiological functions of WM tracts in the spinal cord. Overall, these findings provide evidence of a functional organization of intraspinal WM tracts and confirm that they produce hemodynamic responses similar to GM both at baseline and under stimulus conditions.


Magnetic Resonance Imaging , Saimiri , Spinal Cord , White Matter , Animals , White Matter/diagnostic imaging , White Matter/physiology , Spinal Cord/physiology , Spinal Cord/diagnostic imaging , Magnetic Resonance Imaging/methods , Rest/physiology , Oxygen/blood , Oxygen/metabolism , Male , Gray Matter/diagnostic imaging , Gray Matter/physiology , Female
3.
Article En | MEDLINE | ID: mdl-38780270

Spinal cord injury is associated with spinal vascular disruptions that result in spinal ischemia and tissue hypoxia. This study evaluated the therapeutic efficacy of normobaric hyperoxia on spinal cord oxygenation and circulatory function at the acute stage of cervical spinal cord injury. Adult male Sprague Dawley rats underwent dorsal cervical laminectomy or cervical spinal cord contusion. At 1-2 days after spinal surgery, spinal cord oxygenation was monitored in anesthetized and spontaneously breathing rats through optical recording of oxygen sensor foils placed on the cervical spinal cord and pulse oximetry. The arterial blood pressure, heart rate, blood gases, and peripheral oxyhemoglobin saturation were also measured under hyperoxic (50% O2) and normoxic (21% O2) conditions. The results showed that contused animals had significantly lower spinal cord oxygenation levels than uninjured animals during normoxia. Peripheral oxyhemoglobin saturation, arterial oxygen partial pressure, and mean arterial blood pressure are significantly reduced following cervical spinal cord contusion. Notably, spinal oxygenation of contused rats could be improved to a level comparable to uninjured animals under hyperoxia. Furthermore, acute hyperoxia elevated blood pressure, arterial oxygen partial pressure, and peripheral oxyhemoglobin saturation. These results suggest that normobaric hyperoxia can significantly improve spinal cord oxygenation and circulatory function in the acute phase after cervical spinal cord injury. We propose that adjuvant normobaric hyperoxia combined with other hemodynamic optimization strategies may prevent secondary damage after spinal cord injury and improve functional recovery.


Hyperoxia , Rats, Sprague-Dawley , Spinal Cord Injuries , Animals , Spinal Cord Injuries/therapy , Spinal Cord Injuries/physiopathology , Spinal Cord Injuries/metabolism , Male , Hyperoxia/physiopathology , Hyperoxia/blood , Rats , Oxygen/blood , Oxygen/metabolism , Spinal Cord/metabolism , Spinal Cord/blood supply , Spinal Cord/physiopathology , Cervical Cord/injuries , Cervical Cord/metabolism , Blood Pressure/physiology , Oxyhemoglobins/metabolism , Heart Rate/physiology
4.
J Biomed Opt ; 29(Suppl 3): S33302, 2024 Jun.
Article En | MEDLINE | ID: mdl-38707651

Significance: Cerebral oximeters have the potential to detect abnormal cerebral blood oxygenation to allow for early intervention. However, current commercial systems have two major limitations: (1) spatial coverage of only the frontal region, assuming that surgery-related hemodynamic effects are global and (2) susceptibility to extracerebral signal contamination inherent to continuous-wave near-infrared spectroscopy (NIRS). Aim: This work aimed to assess the feasibility of a high-density, time-resolved (tr) NIRS device (Kernel Flow) to monitor regional oxygenation changes across the cerebral cortex during surgery. Approach: The Flow system was assessed using two protocols. First, digital carotid compression was applied to healthy volunteers to cause a rapid oxygenation decrease across the ipsilateral hemisphere without affecting the contralateral side. Next, the system was used on patients undergoing shoulder surgery to provide continuous monitoring of cerebral oxygenation. In both protocols, the improved depth sensitivity of trNIRS was investigated by applying moment analysis. A dynamic wavelet filtering approach was also developed to remove observed temperature-induced signal drifts. Results: In the first protocol (28±5 years; five females, five males), hair significantly impacted regional sensitivity; however, the enhanced depth sensitivity of trNIRS was able to separate brain and scalp responses in the frontal region. Regional sensitivity was improved in the clinical study given the age-related reduction in hair density of the patients (65±15 years; 14 females, 13 males). In five patients who received phenylephrine to treat hypotension, different scalp and brain oxygenation responses were apparent, although no regional differences were observed. Conclusions: The Kernel Flow has promise as an intraoperative neuromonitoring device. Although regional sensitivity was affected by hair color and density, enhanced depth sensitivity of trNIRS was able to resolve differences in scalp and brain oxygenation responses in both protocols.


Cerebrovascular Circulation , Spectroscopy, Near-Infrared , Humans , Spectroscopy, Near-Infrared/methods , Spectroscopy, Near-Infrared/instrumentation , Female , Male , Adult , Cerebrovascular Circulation/physiology , Hemodynamics/physiology , Oximetry/methods , Oximetry/instrumentation , Oxygen/blood , Oxygen/metabolism , Brain/diagnostic imaging , Brain/blood supply , Equipment Design
5.
Cereb Cortex ; 34(5)2024 May 02.
Article En | MEDLINE | ID: mdl-38752980

The effects of hypoxia on brain function remain largely unknown. This study aimed to clarify this issue by visual-stimulated functional magnetic resonance imaging design. Twenty-three college students with a 30-d high-altitude exposure were tested before, 1 week and 3 months after returning to sea level. Brain functional magnetic resonance imaging and retinal electroretinogram were acquired. One week after returning to sea level, decreased blood oxygenation level dependent in the right lingual gyrus accompanied with increased blood oxygenation level dependent in the frontal cortex and insular cortex, and decreased amplitude of electroretinogram a-wave in right eye; moreover, the bilateral lingual gyri showed increased functional connectivity within the dorsal visual stream pathway, and the blood oxygenation level dependent signals in the right lingual gyrus showed positive correlation with right retinal electroretinogram a-wave. Three months after returning to sea level, the blood oxygenation level dependent signals recovered to normal level, while intensively increased blood oxygenation level dependent signals in a broad of brain regions and decreased retinal electroretinogram were also existed. In conclusion, hypoxic exposure has long-term effects on visual cortex, and the impaired retinal electroretinogram may contribute to it. The increased functional connectivity of dorsal stream may compensate for the decreased function of retinal photoreceptor cells to maintain normal visual function.


Electroretinography , Magnetic Resonance Imaging , Neuronal Plasticity , Visual Pathways , Humans , Male , Young Adult , Female , Neuronal Plasticity/physiology , Visual Pathways/physiology , Visual Pathways/diagnostic imaging , Hypoxia/physiopathology , Adult , Oxygen/blood , Visual Cortex/diagnostic imaging , Visual Cortex/physiology , Brain/physiology , Brain/diagnostic imaging , Photic Stimulation/methods , Retina/physiology , Retina/diagnostic imaging , Brain Mapping/methods
6.
Crit Care Explor ; 6(5): e1094, 2024 May 01.
Article En | MEDLINE | ID: mdl-38727717

OBJECTIVES: Near-infrared spectroscopy (NIRS) is a potentially valuable modality to monitor the adequacy of oxygen delivery to the brain and other tissues in critically ill patients, but little is known about the physiologic determinants of NIRS-derived tissue oxygen saturations. The purpose of this study was to assess the contribution of routinely measured physiologic parameters to tissue oxygen saturation measured by NIRS. DESIGN: An observational sub-study of patients enrolled in the Role of Active Deresuscitation After Resuscitation-2 (RADAR-2) randomized feasibility trial. SETTING: Two ICUs in the United Kingdom. PATIENTS: Patients were recruited for the RADAR-2 study, which compared a conservative approach to fluid therapy and deresuscitation with usual care. Those included in this sub-study underwent continuous NIRS monitoring of cerebral oxygen saturations (SctO2) and quadriceps muscle tissue saturations (SmtO2). INTERVENTION: Synchronized and continuous mean arterial pressure (MAP), heart rate (HR), and pulse oximetry (oxygen saturation, Spo2) measurements were recorded alongside NIRS data. Arterial Paco2, Pao2, and hemoglobin concentration were recorded 12 hourly. Linear mixed effect models were used to investigate the association between these physiologic variables and cerebral and muscle tissue oxygen saturations. MEASUREMENTS AND MAIN RESULTS: Sixty-six patients were included in the analysis. Linear mixed models demonstrated that Paco2, Spo2, MAP, and HR were weakly associated with SctO2 but only explained 7.1% of the total variation. Spo2 and MAP were associated with SmtO2, but together only explained 0.8% of its total variation. The remaining variability was predominantly accounted for by between-subject differences. CONCLUSIONS: Our findings demonstrated that only a small proportion of variability in NIRS-derived cerebral and tissue oximetry measurements could be explained by routinely measured physiologic variables. We conclude that for NIRS to be a useful monitoring modality in critical care, considerable further research is required to understand physiologic determinants and prognostic significance.


Critical Illness , Oximetry , Oxygen Saturation , Spectroscopy, Near-Infrared , Humans , Spectroscopy, Near-Infrared/methods , Male , Female , Oxygen Saturation/physiology , Middle Aged , Aged , Oximetry/methods , Monitoring, Physiologic/methods , Brain/metabolism , Brain/blood supply , United Kingdom , Oxygen/metabolism , Oxygen/blood , Oxygen/analysis , Intensive Care Units , Quadriceps Muscle/metabolism , Quadriceps Muscle/blood supply
7.
J Vis Exp ; (207)2024 May 10.
Article En | MEDLINE | ID: mdl-38801263

The detection of levels of impairment in microvascular oxygen consumption and reactive hyperemia is vital in critical care. However, there are no practical means for a robust and quantitative evaluation. This paper describes a protocol to evaluate these impairments using a hybrid near-infrared diffuse optical device. The device contains modules for near-infrared time-resolved and diffuse correlation spectroscopies and pulse-oximetry. These modules allow the non-invasive, continuous, and real-time measurement of the absolute, microvascular blood/tissue oxygen saturation (StO2) and the blood flow index (BFI) along with the peripheral arterial oxygen saturation (SpO2). This device uses an integrated, computer-controlled tourniquet system to execute a standardized protocol with optical data acquisition from the brachioradialis muscle. The standardized vascular occlusion test (VOT) takes care of the variations in the occlusion duration and pressure reported in the literature, while the automation minimizes inter-operator differences. The protocol we describe focuses on a 3-min occlusion period but the details described in this paper can readily be adapted to other durations and cuff pressures, as well as other muscles. The inclusion of an extended baseline and post-occlusion recovery period measurement allows the quantification of the baseline values for all the parameters and the blood/tissue deoxygenation rate that corresponds to the metabolic rate of oxygen consumption. Once the cuff is released, we characterize the tissue reoxygenation rate, magnitude, and duration of the hyperemic response in BFI and StO2. These latter parameters correspond to the quantification of the reactive hyperemia, which provides information about the endothelial function. Furthermore, the above-mentioned measurements of the absolute concentration of oxygenated and deoxygenated hemoglobin, BFI, the derived metabolic rate of oxygen consumption, StO2, and SpO2 provide a yet-to-be-explored rich data set that can exhibit disease severity, personalized therapeutics, and management interventions.


Critical Care , Hyperemia , Spectroscopy, Near-Infrared , Spectroscopy, Near-Infrared/methods , Hyperemia/metabolism , Humans , Critical Care/methods , Oxygen/metabolism , Oxygen/blood , Oxygen Consumption/physiology , Oximetry/methods , Oximetry/instrumentation , Muscle, Skeletal/metabolism , Muscle, Skeletal/blood supply , Microcirculation/physiology , Microvessels/metabolism , Oxygen Saturation/physiology
8.
Harm Reduct J ; 21(1): 89, 2024 May 03.
Article En | MEDLINE | ID: mdl-38702702

BACKGROUND: In British Columbia, Canada, smoking is the most common modality of drug use among people who die of opioid toxicity. We aimed to assess oxygen saturation (SpO2) while people smoked opioids during a pilot study that introduced continuous pulse oximetry at overdose prevention services (OPS) sites. METHODS: This was an observational cohort study, using a participatory design. We implemented our monitoring protocol from March to August 2021 at four OPS. We included adults (≥ 18 years) presenting to smoke opioids. A sensor taped to participants' fingers transmitted real-time SpO2 readings to a remote monitor viewed by OPS staff. Peer researchers collected baseline data and observed the timing of participants' inhalations. We analyzed SpO2 on a per-event basis. In mixed-effects logistic regression models, drop in minimum SpO2 ≤ 90% in the current minute was our main outcome variable. Inhalation in that same minute was our main predictor. We also examined inhalation in the previous minute, cumulative inhalations, inhalation rate, demographics, co-morbidities, and substance use variables. RESULTS: We recorded 599 smoking events; 72.8% (436/599) had analyzable SpO2 data. Participants' mean age was 38.6 years (SD 11.3 years) and 73.1% were male. SpO2 was highly variable within and between individuals. Drop in SpO2 ≤ 90% was not significantly associated with inhalation in that same minute (OR: 1.2 [0.8-1.78], p = 0.261) or inhalation rate (OR 0.47 [0.20-1.10], p = 0.082). There was an association of SpO2 drop with six cumulative inhalations (OR 3.38 [1.04-11.03], p = 0.043); this was not maintained ≥ 7 inhalations. Demographics, co-morbidities, and drug use variables were non-contributory. CONCLUSIONS: Continuous pulse oximetry SpO2 monitoring is a safe adjunct to monitoring people who smoke opioids at OPS. Our data reflect challenges of real-world monitoring, indicating that greater supports are needed for frontline responders at OPS. Inconsistent association between inhalations and SpO2 suggests that complex factors (e.g., inhalation depth/duration, opioid tolerance, drug use setting) contribute to hypoxemia and overdose risk while people smoke opioids.


Analgesics, Opioid , Drug Overdose , Oximetry , Humans , Male , Female , British Columbia/epidemiology , Adult , Middle Aged , Drug Overdose/prevention & control , Oxygen Saturation , Pilot Projects , Smoking/epidemiology , Cohort Studies , Oxygen/blood , Harm Reduction
9.
BMC Psychiatry ; 24(1): 367, 2024 May 15.
Article En | MEDLINE | ID: mdl-38750494

BACKGROUND: Postoperative delirium (POD) represents a prevalent and noteworthy complication in the context of pediatric surgical interventions. In recent times, a hypothesis has emerged positing that cerebral ischemia and regional cerebral oxygen desaturation might serve as potential catalysts in the pathogenesis of POD. The primary aim of this study was to methodically examine the potential relationship between POD and regional cerebral oxygen saturation (rSO2) and to assess the predictive and evaluative utility of rSO2 in the context of POD. METHODS: This prospective observational study was conducted at the Children's Hospital, Zhejiang University School of Medicine, Zhejiang, China, spanning the period from November 2020 to March 2021. The research cohort comprised children undergoing surgical procedures within this clinical setting. To measure rSO2 dynamics, cerebral near-infrared spectroscopy (NIRS) was used to monitor rSO2 levels both before and after surgery. In addition, POD was assessed in the paediatric patients according to the Diagnostic and Statistical Manual of Mental Disorders Fifth Edition (DSM-5) criteria. The analysis of the association between the rSO2 index and the incidence of POD was carried out through the application of either the independent samples t-test or the nonparametric rank-sum test. To ascertain the threshold value of the adjusted rSO2 index for predictive and evaluative purposes regarding POD in the pediatric population, the Receiver Operating Characteristics (ROC) curve was employed. RESULTS: A total of 211 cases were included in this study, of which 61 (28.9%) developed POD. Participants suffering delirium had lower preoperative rSO2mean, lower preoperative rSO2min, and lower postoperative rSO2min, higher ∆rSO2mean, higher amount of ∆rSO2mean, lower ∆rSO2min (P < 0.05). Preoperative rSO2mean (AUC = 0.716, 95%CI 0.642-0.790), ∆rSO2mean (AUC = 0.694, 95%CI 0.614-0.774), amount of ∆rSO2mean (AUC = 0.649, 95%CI 0.564-0.734), preoperative rSO2min (AUC = 0.702, 96%CI 0.628-0.777), postoperative rSO2min (AUC = 0.717, 95%CI 0.647-0.787), and ∆rSO2min (AUC = 0.714, 95%CI 0.638-0.790) performed well in sensitivity and specificity, and the best threshold were 62.05%, 1.27%, 2.41%, 55.68%, 57.36%, 1.29%. CONCLUSIONS: There is a close relationship between pediatric POD and rSO2. rSO2 could be used as an effective predictor of pediatric POD. It might be helpful to measure rSO2 with NIRS for early recognizing POD and making it possible for early intervention.


Delirium , Oxygen Saturation , Postoperative Complications , Spectroscopy, Near-Infrared , Humans , Prospective Studies , Female , Male , Child , Oxygen Saturation/physiology , Postoperative Complications/metabolism , Postoperative Complications/diagnosis , Child, Preschool , Delirium/metabolism , Delirium/diagnosis , China , Adolescent , Brain/metabolism , Infant , Oxygen/metabolism , Oxygen/blood
10.
PLoS One ; 19(5): e0304278, 2024.
Article En | MEDLINE | ID: mdl-38814919

OBJECTIVE: To investigate the correlation between oxygen saturation index (OSI) and oxygenation index (OI) for evaluating the blood oxygenation status in neonates with respiratory failure requiring mechanical ventilation support and to assess the predictive capability of OSI in determining clinically relevant OI cutoffs. METHODS: A prospective study was conducted on neonates who received invasive mechanical ventilation at the neonatal intensive care unit of tertiary hospital in Vietnam. Bland-Altman analysis was utilized to evaluate the agreement between OSI and OI. RESULTS: A total of 123 neonates, including both term and preterm infants, were included in the study. A high agreement rate of 94.3% within the 95% limits of agreement (between OI and OSI), with a narrow similarity value of 3.3 (95% CI: -5.1 to 11.8) and high correlation coefficient (r = 0.791, p<0.001) was observed. The OSI cut-off value for predicting an OI of >15 was determined to be 7.45, with a sensitivity of 100% and a specificity of 87.4% (AUC 0.955; 95% CI: 0.922-0.989, p < 0.05). Similarly, an OSI cutoff value of 9.9 corresponded to an OI of 25, displaying a sensitivity of 100% and specificity of 87.4% (AUC 0.92). The receiver operating characteristic (ROC) curves for OSI exhibited statistically significant results (p < 0.05). CONCLUSION: The findings demonstrate a strong correlation between OSI and OI in neonates with respiratory failure. Furthermore, OSI, as a non-invasive method, can serve as a substitute for OI to evaluate the severity of hypoxic respiratory failure and lung injury in neonates.


Oxygen Saturation , Respiration, Artificial , Respiratory Insufficiency , Humans , Infant, Newborn , Respiratory Insufficiency/therapy , Respiratory Insufficiency/blood , Male , Female , Prospective Studies , Hypoxia/blood , Hypoxia/diagnosis , Oxygen/metabolism , Oxygen/blood , Intensive Care Units, Neonatal , Infant, Premature , ROC Curve
11.
Placenta ; 151: 59-66, 2024 Jun.
Article En | MEDLINE | ID: mdl-38718734

INTRODUCTION: To evaluate the maternal and fetal hemodynamic effects of treatment with a nitric oxide donor and oral fluid in pregnancies complicated by fetal growth restriction. METHODS: 30 normotensive participants with early fetal growth restriction were enrolled. 15 participants were treated until delivery with transdermal glyceryl trinitrate and oral fluid intake (Treated group), and 15 comprised the untreated group. All women underwent non-invasive assessment of fetal and maternal hemodynamics and repeat evaluation 2 weeks later. RESULTS: In the treated group, maternal hemodynamics improved significantly after two weeks of therapy compared to untreated participants. Fetal hemodynamics in the treated group showed an increase in umbilical vein diameter by 18.87 % (p < 0.01), in umbilical vein blood flow by 48.16 % (p < 0.01) and in umbilical vein blood flow corrected for estimated fetal weight by 30.03 % (p < 0.01). In the untreated group, the characteristics of the umbilical vein were unchanged compared to baseline. At the same time, the cerebro-placental ratio increased in the treated group, while it was reduced in the untreated group, compared to baseline values. The treated group showed a higher birthweight centile (p = 0.03) and a lower preeclampsia rate (p = 0.04) compared to the untreated group. DISCUSSION: The combined therapeutic approach with nitric oxide donor and oral fluid intake in fetal growth restriction improves maternal hemodynamics, which becomes more hyperdynamic (volume-dominant). At the same time, in the fetal circuit, umbilical vein flow increased and fetal brain sparing improved. Although a modest sample size, there was less preeclampsia and a higher birthweight suggesting beneficial maternal and fetal characteristics of treatment.


Fetal Growth Retardation , Nitric Oxide Donors , Umbilical Veins , Humans , Female , Fetal Growth Retardation/metabolism , Fetal Growth Retardation/physiopathology , Pregnancy , Pilot Projects , Nitric Oxide Donors/pharmacology , Nitric Oxide Donors/administration & dosage , Adult , Nitroglycerin/pharmacology , Nitroglycerin/administration & dosage , Hemodynamics/drug effects , Fetus/blood supply , Fetus/metabolism , Young Adult , Oxygen/metabolism , Oxygen/blood
12.
J Matern Fetal Neonatal Med ; 37(1): 2349179, 2024 Dec.
Article En | MEDLINE | ID: mdl-38816997

OBJECTIVE: To investigate whether aryl hydrocarbon receptor (AhR) is involved in hyperoxia-mediated oxidative stress by observing the relationship between AhR and reactive oxygen species (ROS) in peripheral blood mononuclear cells (PBMCs) after oxygen exposure in premature infants. METHODS: After 48 h of oxygen inhalation at different concentrations, discarded peripheral blood was collected to separate PBMCs and plasma. ROS were labeled with MitoSOXTM Red and detected by fluorescence microscopy in PBMCs. The level of MDA in plasma was detected by thiobarbituric acid colorimetry, the level of MCP-1 in plasma was detected by enzyme-linked immunosorbent assay (ELISA), the localization of AhR was detected by immunofluorescence, and the level of AhR expression in PBMCs was detected by Western blotting. RESULTS: As the volume fraction of inspired oxygen increased, compared with those in the air control group, the levels of ROS, MDA in plasma, and MCP-1 in plasma increased gradually in the low concentration oxygen group, medium concentration oxygen group and high concentration oxygen group. The cytoplasm-nuclear translocation rate of AhR gradually increased, and the expression level of AhR gradually decreased. The levels of ROS in PBMCs, MDA in the plasma and MCP-1 in the plasma of premature infants were positively correlated with the cytoplasm-nuclear translocation rate of AhR but negatively correlated with the level of AhR expression. CONCLUSION: Aryl hydrocarbon receptor (AhR) is regulated by hyperoxia in premature infants.


Hyperoxia , Infant, Premature , Reactive Oxygen Species , Receptors, Aryl Hydrocarbon , Humans , Receptors, Aryl Hydrocarbon/metabolism , Hyperoxia/metabolism , Infant, Newborn , Infant, Premature/blood , Infant, Premature/metabolism , Reactive Oxygen Species/metabolism , Oxidative Stress/physiology , Leukocytes, Mononuclear/metabolism , Female , Male , Oxygen/metabolism , Oxygen/blood , Basic Helix-Loop-Helix Transcription Factors
13.
Turk J Med Sci ; 54(1): 99-114, 2024.
Article En | MEDLINE | ID: mdl-38812632

Background/aim: In this prospective observational study, our goal was to investigate the relationship between serum levels of oxidative stress (OS) parameters and regional cerebral oxygen saturation (rSO2) in addition to evaluating postoperative clinical outcomes among patients undergoing coronary artery bypass graft surgery (CABG). Materials and methods: This study comprised 64 adult patients undergoing elective CABG (on-pump [n = 48] and off-pump [n = 16]) procedures. Serum OS levels and rSO2 values were measured intraoperatively at three specific time points: T1 (after induction), T2 (15 min before aortic cross-clamp removal or the final distal anastomosis), and T3 (15 min after aortic cross-clamp removal or the last distal anastomosis). Results: Serum OS and lactate values demonstrated higher levels at T2 and T3 (p < 0.001), while rSO2 values were lower at T2 (p = 0.024) in the on-pump CABG group compared to the off-pump CABG group. The rSO2 values at T2 exhibited a negative correlation with OS parameters, lactate levels at T2 and T3, aortic clamp time, postoperative mechanical ventilation time, and intensive care unit stay length. In the multivariate linear regression analysis (R2 = 0.181, p = 0.001), lactate values at T2 emerged as the sole factor affecting the OS index at T2 (t = 2.843, p = 0.006). Conclusion: In our study, we observed elevated OS values and relatively low rSO2 values during on-pump CABG procedures, with rSO2 showing an association with increased OS parameters. Close monitoring of the OS response level and rSO2 during CABG could potentially enhance postoperative clinical outcomes.


Coronary Artery Bypass, Off-Pump , Coronary Artery Bypass , Oxidative Stress , Humans , Male , Female , Prospective Studies , Middle Aged , Coronary Artery Bypass, Off-Pump/adverse effects , Oxidative Stress/physiology , Aged , Brain/metabolism , Oxygen/blood , Oxygen/metabolism , Oxygen Saturation/physiology
15.
Comput Methods Programs Biomed ; 251: 108204, 2024 Jun.
Article En | MEDLINE | ID: mdl-38728829

PURPOSE: This study aimed to investigate the effects of lower-extremity cannulation on the intra-arterial hemodynamic environment, oxygen content, blood damage, and thrombosis risk under different levels of veno-arterial (V-A) ECMO support. METHODS: Computational fluid dynamics methods were used to investigate the effects of different levels of ECMO support (ECMO flow ratios supplying oxygen-rich blood 100-40 %). Flow rates and oxygen content in each arterial branch were used to determine organ perfusion. A new thrombosis model considering platelet activation and deposition was proposed to determine the platelet activation and thrombosis risk at different levels of ECMO support. A red blood cell damage model was used to explore the risk of hemolysis. RESULTS: Our study found that partial recovery of cardiac function improved the intra-arterial hemodynamic environment, with reduced impingement of the intra-arterial flow field by high-velocity blood flow from the cannula, a flow rate per unit time into each arterial branch closer to physiological levels, and improved perfusion in the lower extremities. Partial recovery of cardiac function helps reduce intra-arterial high shear stress and residence time, thereby reducing blood damage. The overall level of hemolysis and platelet activation in the aorta decreased with the gradual recovery of cardiac contraction function. The areas at high risk of thrombosis under V-A ECMO femoral cannulation support were the aortic root and the area distal to the cannula, which moved to the descending aorta when cardiac function recovered to 40-60 %. However, with the recovery of cardiac contraction function, hypoxic blood pumped by the heart is insufficient in supplying oxygen to the front of the aortic arch, which may result in upper extremity hypoxia. CONCLUSION: We developed a thrombosis risk prediction model applicable to ECMO cannulation and validated the model accuracy using clinical data. Partial recovery of cardiac function contributed to an improvement in the aortic hemodynamic environment and a reduction in the risk of blood damage; however, there is a potential risk of insufficient perfusion of oxygen-rich blood to organs.


Catheterization , Extracorporeal Membrane Oxygenation , Oxygen , Thrombosis , Extracorporeal Membrane Oxygenation/methods , Extracorporeal Membrane Oxygenation/adverse effects , Humans , Thrombosis/etiology , Thrombosis/prevention & control , Oxygen/blood , Hemodynamics , Lower Extremity/blood supply , Models, Cardiovascular , Hemolysis , Platelet Activation
16.
Sci Data ; 11(1): 535, 2024 May 24.
Article En | MEDLINE | ID: mdl-38789452

Pulse oximeters measure peripheral arterial oxygen saturation (SpO2) noninvasively, while the gold standard (SaO2) involves arterial blood gas measurement. There are known racial and ethnic disparities in their performance. BOLD is a dataset that aims to underscore the importance of addressing biases in pulse oximetry accuracy, which disproportionately affect darker-skinned patients. The dataset was created by harmonizing three Electronic Health Record databases (MIMIC-III, MIMIC-IV, eICU-CRD) comprising Intensive Care Unit stays of US patients. Paired SpO2 and SaO2 measurements were time-aligned and combined with various other sociodemographic and parameters to provide a detailed representation of each patient. BOLD includes 49,099 paired measurements, within a 5-minute window and with oxygen saturation levels between 70-100%. Minority racial and ethnic groups account for ~25% of the data - a proportion seldom achieved in previous studies. The codebase is publicly available. Given the prevalent use of pulse oximeters in the hospital and at home, we hope that BOLD will be leveraged to develop debiasing algorithms that can result in more equitable healthcare solutions.


Blood Gas Analysis , Oximetry , Humans , Oxygen Saturation , Intensive Care Units , Ethnicity , Oxygen/blood
17.
Neurosurg Rev ; 47(1): 222, 2024 May 17.
Article En | MEDLINE | ID: mdl-38758384

To assess whether monitoring brain tissue oxygen partial pressure (PbtO2) or employing intracranial pressure (ICP)/cerebral perfusion pressure (CCP)-guided management improves patient outcomes, including mortality, hospital length of stay (LOS), mean daily ICP and mean daily CCP during the intensive care unit(ICU)stay. We searched the Web of Science, EMBASE, PubMed, Cochrane Library, and MEDLINE databases until December 12, 2023. Prospective randomized controlled and cohort studies were included. A meta-analysis was performed for the primary outcome measure, mortality, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Eleven studies with a total of 37,492 patients were included. The mortality in the group with PbtO2 was 29.0% (odds ratio: 0.73;95% confidence interval [CI]:0.56-0.96; P = 0.03; I = 55%), demonstrating a significant benefit. The overall hospital LOS was longer in the PbtO2 group than that in the ICP/CPP group (mean difference:2.03; 95% CI:1.03-3.02; P<0.0001; I = 39%). The mean daily ICP in the PbtO2 monitoring group was lower than that in the ICP/CPP group (mean difference:-1.93; 95% CI: -3.61 to -0.24; P = 0.03; I = 41%). Moreover, PbtO2 monitoring did not improve the mean daily CPP (mean difference:2.43; 95%CI: -1.39 to 6.25;P = 0.21; I = 56%).Compared with ICP/CPP monitoring, PbtO2 monitoring reduced the mortality and the mean daily ICP in patients with severe traumatic brain injury; however, no significant effect was noted on the mean daily CPP. In contrast, ICP/CPP monitoring alone was associated with a short hospital stay.


Brain Injuries, Traumatic , Brain , Intracranial Pressure , Oxygen , Humans , Brain Injuries, Traumatic/mortality , Brain Injuries, Traumatic/diagnosis , Brain Injuries, Traumatic/therapy , Cerebrovascular Circulation/physiology , Intracranial Pressure/physiology , Length of Stay , Monitoring, Physiologic/methods , Oxygen/metabolism , Oxygen/blood , Partial Pressure , Prognosis
18.
BMC Anesthesiol ; 24(1): 187, 2024 May 25.
Article En | MEDLINE | ID: mdl-38796436

PURPOSE: Oxygen delivery (DO2) and its monitoring are highlighted to aid postoperative goal directed therapy (GDT) to improve perioperative outcomes such as acute kidney injury (AKI) after high-risk cardiac surgeries associated with multiple morbidities and mortality. However, DO2 monitoring is neither routine nor done postoperatively, and current methods are invasive and only produce intermittent DO2 trends. Hence, we proposed a novel algorithm that simultaneously integrates cardiac output (CO), hemoglobin (Hb) and oxygen saturation (SpO2) from the Edwards Life Sciences ClearSight System® and Masimo SET Pulse CO-Oximetry® to produce a continuous, real-time DO2 trend. METHODS: Our algorithm was built systematically with 4 components - machine interface to draw data with PuTTY, data extraction with parsing, data synchronization, and real-time DO2 presentation using a graphic-user interface. Hb readings were validated. RESULTS: Our algorithm was implemented successfully in 93% (n = 57 out of 61) of our recruited cardiac surgical patients. DO2 trends and AKI were studied. CONCLUSION: We demonstrated a novel proof-of-concept and feasibility of continuous, real-time, non-invasive DO2 monitoring, with each patient serving as their own control. Our study also lays the foundation for future investigations aimed at identifying personalized critical DO2 thresholds and optimizing DO2 as an integral part of GDT to enhance outcomes in perioperative cardiac surgery.


Algorithms , Cardiac Surgical Procedures , Feasibility Studies , Oximetry , Oxygen , Humans , Cardiac Surgical Procedures/methods , Male , Female , Oxygen/metabolism , Oxygen/administration & dosage , Oxygen/blood , Oximetry/methods , Aged , Middle Aged , Proof of Concept Study , Acute Kidney Injury , Monitoring, Physiologic/methods , Cardiac Output/physiology , Hemoglobins/metabolism , Hemoglobins/analysis , Oxygen Saturation/physiology
19.
West J Emerg Med ; 25(3): 325-331, 2024 May.
Article En | MEDLINE | ID: mdl-38801037

Background: Patients with coronavirus 2019 (COVID-19) are at high risk for respiratory dysfunction. The pulse oximetry/fraction of inspired oxygen (SpO2/FiO2) ratio is a non-invasive assessment of respiratory dysfunction substituted for the PaO2:FiO2 ratio in Sequential Organ Failure Assessment scoring. We hypothesized that emergency department (ED) SpO2/FiO2 ratios correlate with requirement for mechanical ventilation in COVID-19 patients. Our objective was to identify COVID-19 patients at greatest risk of requiring mechanical ventilation, using SpO2/FiO2 ratios. Methods: We performed a retrospective review of patients admitted with COVID-19 at two hospitals. Highest and lowest SpO2/FiO2 ratios (percent saturation/fraction of inspired O2) were calculated on admission. We performed chi-square, univariate, and multiple regression analysis to evaluate the relationship of admission SpO2/FiO2 ratios with requirement for mechanical ventilation and intensive care unit (ICU) care. Results: A total of 539 patients (46% female; 84% White), with a mean age 67.6 ± 18.6 years, met inclusion criteria. Patients who required mechanical ventilation during their hospital stay were statistically younger in age (P = 0.001), had a higher body mass index (P < .001), and there was a higher percentage of patients who were obese (P = 0.03) and morbidly obese (P < .001). Shortness of breath, cough, and fever were the most common presenting symptoms with a median temperature of 99°F. Average white blood count was higher in patients who required ventilation (P = <0.001). A highest obtained ED SpO2/FiO2 ratio of ≤300 was associated with a requirement for mechanical ventilation. A lowest obtained ED SpO2/FiO2 ratio of ≤300 was associated with a requirement for intensive care unit care. There was no statistically significant correlation between ED SpO2/FiO2 ratios >300 and mechanical ventilation or intensive care unit (ICU) requirement. Conclusion: The ED SpO2/FiO2 ratios correlated with mechanical ventilation and ICU requirements during hospitalization for COVID-19. These results support ED SpO2/FiO2 as a possible triage tool and predictor of hospital resource requirements for patients admitted with COVID-19. Further investigation is warranted.


COVID-19 , Emergency Service, Hospital , Intensive Care Units , Oximetry , Respiration, Artificial , Humans , COVID-19/therapy , COVID-19/blood , COVID-19/epidemiology , COVID-19/diagnosis , Female , Retrospective Studies , Male , Aged , SARS-CoV-2 , Middle Aged , Oxygen Saturation , Oxygen/blood , Aged, 80 and over
20.
Exp Physiol ; 109(6): 980-991, 2024 Jun.
Article En | MEDLINE | ID: mdl-38606906

Increasing placental perfusion (PP) could improve outcomes of growth-restricted fetuses. One way of increasing PP may be by using phosphodiesterase (PDE)-5 inhibitors, which induce vasodilatation of vascular beds. We used a combination of clinically relevant magnetic resonance imaging (MRI) techniques to characterize the impact that tadalafil infusion has on maternal, placental and fetal circulations. At 116-117 days' gestational age (dGA; term, 150 days), pregnant ewes (n = 6) underwent fetal catheterization surgery. At 120-123 dGA ewes were anaesthetized and MRI scans were performed during three acquisition windows: a basal state and then ∼15-75 min (TAD 1) and ∼75-135 min (TAD 2) post maternal administration (24 mg; intravenous bolus) of tadalafil. Phase contrast MRI and T2 oximetry were used to measure blood flow and oxygen delivery. Placental diffusion and PP were assessed using the Diffusion-Relaxation Combined Imaging for Detailed Placental Evaluation-'DECIDE' technique. Uterine artery (UtA) blood flow when normalized to maternal left ventricular cardiac output (LVCO) was reduced in both TAD periods. DECIDE imaging found no impact of tadalafil on placental diffusivity or fetoplacental blood volume fraction. Maternal-placental blood volume fraction was increased in the TAD 2 period. Fetal D O 2 ${D_{{{\mathrm{O}}_2}}}$ and V ̇ O 2 ${\dot V_{{{\mathrm{O}}_2}}}$ were not affected by maternal tadalafil administration. Maternal tadalafil administration did not increase UtA blood flow and thus may not be an effective vasodilator at the level of the UtAs. The increased maternal-placental blood volume fraction may indicate local vasodilatation of the maternal intervillous space, which may have compensated for the reduced proportion of UtA D O 2 ${D_{{{\mathrm{O}}_2}}}$ .


Oxygen , Placenta , Placental Circulation , Tadalafil , Uterine Artery , Animals , Female , Tadalafil/pharmacology , Tadalafil/administration & dosage , Pregnancy , Sheep , Uterine Artery/drug effects , Placenta/drug effects , Placenta/blood supply , Placental Circulation/drug effects , Oxygen/blood , Regional Blood Flow/drug effects , Phosphodiesterase 5 Inhibitors/pharmacology , Phosphodiesterase 5 Inhibitors/administration & dosage , Magnetic Resonance Imaging , Fetus/blood supply , Fetus/drug effects
...