Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 3.481
1.
J Robot Surg ; 18(1): 204, 2024 May 08.
Article En | MEDLINE | ID: mdl-38714574

Workflow for cortical bone trajectory (CBT) screws includes tapping line-to-line or under tapping by 1 mm. We describe a non-tapping, two-step workflow for CBT screw placement, and compare the safety profile and time savings to the Tap (three-step) workflow. Patients undergoing robotic assisted 1-3 level posterior fusion with CBT screws for degenerative conditions were identified and separated into either a No-Tap or Tap workflow. Number of total screws, screw-related complications, estimated blood loss, operative time, robotic time, and return to the operating room were collected and analyzed. There were 91 cases (458 screws) in the No-Tap and 88 cases (466 screws) in the Tap groups, with no difference in demographics, revision status, ASA grade, approach, number of levels fused or diagnosis between cohorts. Total robotic time was lower in the No-Tap (26.7 min) versus the Tap group (30.3 min, p = 0.053). There was no difference in the number of malpositioned screws identified intraoperatively (10 vs 6, p = 0.427), screws converted to freehand (3 vs 3, p = 0.699), or screws abandoned (3 vs 2, p = 1.000). No pedicle/pars fracture or fixation failure was seen in the No-Tap cohort and one in the Tap cohort (p = 1.00). No patients in either cohort were returned to OR for malpositioned screws. This study showed that the No-Tap screw insertion workflow for robot-assisted CBT reduces robotic time without increasing complications.


Cortical Bone , Robotic Surgical Procedures , Spinal Fusion , Humans , Robotic Surgical Procedures/methods , Robotic Surgical Procedures/instrumentation , Male , Female , Middle Aged , Cortical Bone/surgery , Aged , Spinal Fusion/methods , Spinal Fusion/instrumentation , Operative Time , Bone Screws , Workflow , Pedicle Screws , Adult
2.
PLoS One ; 19(5): e0302996, 2024.
Article En | MEDLINE | ID: mdl-38718026

The success rate of spinal fusion surgery is mainly determined by the fixation strength of the spinal bone anchors. This study explores the use of an L-shaped spinal bone anchor that is intended to establish a macro-shape lock with the posterior cortical layer of the vertebral body, thereby increasing the pull-out resistance of the anchor. The performance of this L-shaped anchor was evaluated in lumbar vertebra phantoms (L1-L5) across four distinct perpendicular orientations (lateral, medial, superior, and inferior). During the pull-out experiments, the pull-out force, and the displacement of the anchor with respect to the vertebra was measured which allowed the determination of the maximal pull-out force (mean: 123 N ± 25 N) and the initial pull-out force, the initial force required to start motion of the anchor (mean: 23 N ± 16 N). Notably, the maximum pull-out force was observed when the anchor engaged the cortical bone layer. The results demonstrate the potential benefits of utilising a spinal bone anchor featuring a macro-shape lock with the cortical bone layer to increase the pull-out force. Combining the macro shape-lock fixation method with the conventional pedicle screw shows the potential to significantly enhance the fixation strength of spinal bone anchors.


Lumbar Vertebrae , Spinal Fusion , Humans , Lumbar Vertebrae/surgery , Spinal Fusion/methods , Spinal Fusion/instrumentation , Pedicle Screws , Biomechanical Phenomena , Suture Anchors
3.
Georgian Med News ; (348): 117-121, 2024 Mar.
Article En | MEDLINE | ID: mdl-38807404

Highlighting the prospective evaluation of the surgical outcome of pedicle screw usage in the treatment of degenerative lumbar spine disease in fifty-five patients who were treated consecutively via a posterior surgical approach with pedicle screw fixation. A total of 55 consecutive patients with degenerative lumbosacral spine disease were treated at AL Mosul Teaching Hospital. Patients were included if they were between the ages of 25 and 60 years, they were admitted to the hospital with chronic back pain and or radicular pain and had a pedicle anatomy (based on a preoperative X-ray) that could accommodate surgical stabilization with PS instrumentation and fusion. Posterior surgical stabilization of the degenerative lumbar spine disease with pedicular screws was done and before discharge, each patient underwent a postoperative X-ray of the lumbosacral spine. In this series 55 patients were operated on for pedicular screw fixation with connecting bar, all patients underwent decompression except 2 cases, 47 patients with 2-level fixation and 8 patients with 3-level fixation. All patients' pain disappeared or became less, as well as paraesthesia.10 patients with lower limb neurological deficits improved. Only 5 of all patients are re-operated (three due to displacement, one due to a broken screw, and one due to a loose screw), 3 patients developed Dural tears and were treated by suturing with muscle patch, no vascular injury, no post-operative infection seen but one patient developed DVT post-operatively treated conservatively. Pedicle screw fixation facilitates the bone-fusion process, and its use is associated with a relatively low complication rate. The application of pedicle screws can be technically demanding; a thorough working knowledge of spinal anatomy and the principles of pedicle screw insertion will greatly contribute to their safe and accurate placement. These devices should be used when there is any feature of instability or due to iatrogenic instability after wide bone removal or after the destruction of facet joints.


Lumbar Vertebrae , Pedicle Screws , Humans , Middle Aged , Adult , Lumbar Vertebrae/surgery , Lumbar Vertebrae/diagnostic imaging , Female , Male , Treatment Outcome , Spinal Fusion/methods , Spinal Fusion/instrumentation , Bone Screws , Prospective Studies , Decompression, Surgical/methods , Lumbosacral Region/surgery
4.
BMC Musculoskelet Disord ; 25(1): 418, 2024 May 28.
Article En | MEDLINE | ID: mdl-38807200

BACKGROUND: It was reported the paraspinal muscle played an important role in spinal stability. The preoperative paraspinal muscle was related to S1 screw loosening. But the relationship between preoperative and postoperative change of psoas major muscle (PS) and S1 pedicle screw loosening in degenerative lumbar spinal stenosis (DLSS) patients has not been reported. This study investigated the effects of preoperative and follow-up variations in the psoas major muscle (PS) on the first sacral vertebra (S1) screw loosening in patients with DLSS. METHODS: 212 patients with DLSS who underwent lumbar surgery were included. The patients were divided into the S1 screw loosening group and the S1 screw non-loosening group. Muscle parameters were measured preoperatively and at last follow-up magnetic resonance imaging. A logistic regression analysis was performed to investigate the risk factors for S1 screw loosening. RESULTS: The S1 screw loosening rate was 36.32% (77/212). The relative total cross-sectional areas and relative functional cross-sectional areas (rfCSAs) of the PS at L2-S1 were significantly higher after surgery. The increased rfCSA values of the PS at L3-S1 in the S1 screw non-loosening group were significantly higher than those in the S1 screw loosening group. The regression analysis showed male, lower CT value of L1 and longer segment fusion were independent risk factors for S1 screw loosening, and postoperative hypertrophy of the PS was a protective factor for S1 screw loosening. CONCLUSIONS: Compared to the preoperative muscle, the PS size increased and fatty infiltration decreased after surgery from L2-3 to L5-S1 in patients with DLSS after short-segment lumbar fusion surgery. Postoperative hypertrophy of the PS might be considered as a protective factor for S1 screw loosening. MRI morphometric parameters and postoperative selected exercise of PS for DLSS patients after posterior lumbar fusion surgery might contribute to improvement of surgical outcome.


Lumbar Vertebrae , Pedicle Screws , Psoas Muscles , Spinal Fusion , Spinal Stenosis , Humans , Male , Spinal Stenosis/surgery , Spinal Stenosis/diagnostic imaging , Female , Lumbar Vertebrae/surgery , Lumbar Vertebrae/diagnostic imaging , Aged , Psoas Muscles/diagnostic imaging , Middle Aged , Follow-Up Studies , Spinal Fusion/instrumentation , Spinal Fusion/adverse effects , Magnetic Resonance Imaging , Sacrum/diagnostic imaging , Sacrum/surgery , Retrospective Studies , Risk Factors , Aged, 80 and over , Preoperative Period
5.
Zhongguo Gu Shang ; 37(5): 470-6, 2024 May 25.
Article Zh | MEDLINE | ID: mdl-38778530

OBJECTIVE: To explore the clinical effect of percutaneous pedicle screw anchored vertebral augmentation(PPSAVA) in the treatment of asymptomatic Kümmell disease without neurological symptoms. METHODS: The clinical data of 20 patients with Kümmell disease without neurological symptoms treated with PPSAVA in our hospital from January 2019 to December 2021 were analyzed retrospectively, including 5 males and 15 females, aged 56 to 88 (74.95±9.93) years old. and the course of disease was 7 to 60 days with an average of (21.35±14.46) days. All patients were treated with PPSAVA. The time of operation, the amount of bone cement injected and the leakage of bone cement were recorded. The visual analogue scale(VAS), Oswestry disability index(ODI), vertebral body angle(VBA), anterior edge height and midline height of vertebral body were compared among the before operation, 3 days after operation and during the final follow-up. The loosening and displacement of bone cement were observed during the final follow-up. RESULTS: All the 20 patients completed the operation successfully. The operation time was 30 to 56 min with an average of (41.15±7.65) min, and the amount of bone cement injection was 6.0 to 12.0 ml with an average of (9.30±1.49) ml. Bone cement leakage occurred in 6 cases and there were no obvious clinical symptoms. The follow-up time was 6 to 12 months with an average of (8.43±2.82) months. The VBA, anterior edge height and midline height of of injured vertebral body were significantly improved 3 days after operation and the final follow-up(P<0.05), and the VBA, anterior edge height and midline height of of injured vertebral body were lost in different degrees at the final follow-up (P<0.05). The VAS and ODI at 3 days after operation and at the final follow-up were significantly lower than those at preoperatively(P<0.05), but the VAS score and ODI at the final follow-up were not significantly different from those at 3 d after operation(P>0.05). At the last follow-up, no patients showed loosening or displacement of bone cement. CONCLUSION: PPSAVA is highly effective in treating Kümmell disease without neurological symptoms, improving patients' pain and functional impairment, and reducing the risk of cement loosening and displacement postoperatively.


Pedicle Screws , Humans , Female , Male , Aged , Middle Aged , Aged, 80 and over , Retrospective Studies , Spinal Fractures/surgery , Bone Cements
6.
Sci Rep ; 14(1): 10881, 2024 05 13.
Article En | MEDLINE | ID: mdl-38740762

This cadaveric study aimed to evaluate the safety and usability of a novel robotic system for posterior cervical pedicle screw fixation. Three human cadaveric specimens and C2-T3 were included. Freshly frozen human cadaver specimens were prepared and subjected to robot-assisted posterior cervical pedicle screw fixation using the robotic system. The accuracy of screw placement, breach rate, and critical structure violations were evaluated. The results were statistically compared with those of previous studies that used different robotic systems for cervical pedicle screw fixation. The robotic system demonstrated a high accuracy rate in screw placement. A significant number of screws were placed within predetermined safe zones. The total entry offset was 1.08 ± 0.83 mm, the target offset was 1.86 ± 0.50 mm, and the angle offset was 2.14 ± 0.77°. Accuracy rates comparable with those of previous studies using different robotic systems were achieved. The system was also feasible, allowing precise navigation and real-time feedback during the procedure. This cadaveric study validated the safety and usability of the novel robotic system for posterior cervical pedicle screw fixation. The system exhibited high precision in screw placement, and the results support the extension of the indications for robot-assisted pedicle screw fixation from the lumbar spine to the cervical spine.


Cadaver , Cervical Vertebrae , Feasibility Studies , Pedicle Screws , Robotic Surgical Procedures , Humans , Cervical Vertebrae/surgery , Robotic Surgical Procedures/methods , Robotic Surgical Procedures/instrumentation , Spinal Fusion/methods , Spinal Fusion/instrumentation , Male , Female
7.
Medicine (Baltimore) ; 103(20): e38258, 2024 May 17.
Article En | MEDLINE | ID: mdl-38758846

BACKGROUND: The aim of this study was to compare the biomechanical performance of pedicle screw construction and locking compression plate fixation in posterior pelvic ring injuries analyzed by finite element method. METHODS: A 3-dimensional finite element model of the spine-pelvis-femur complex with ligaments was reconstructed from computed tomography images. An unstable posterior pelvic ring injury was created, which was fixed with a pedicle screw construction or locking compression plate. A follower load of 400 N was applied to the upper surface of the vertebrae to simulate the upper body weight, while the ends of the proximal femurs were fixed. The construct stiffness, the maximum vertical displacement, the maximum posterior displacement, the maximum right displacement, and the overall maximum displacement of the sacrum, and stress distributions of the implants and pelvises were assessed. RESULTS: The construct stiffness of the pedicle screw model (435.14 N/mm) was 2 times that of the plate model (217.01 N/mm). The maximum vertical displacement, the maximum posterior displacement, the maximum right displacement, and the overall maximum displacement of the sacrum in the pedicle screw model were smaller than those in the plate model (0.919, 1.299, 0.259, and 1.413 mm in the pedicle screw model, and 1.843, 2.300, 1.053, and 2.895 mm in the plate model, respectively). The peak stresses of the implant and pelvis in the pedicle screw model decreased by 80.4% and 25% when compared with the plate model (44.57 and 34.48 MPa in the pedicle screw model, and 227.47 and 45.97 MPa in the plate model, respectively). CONCLUSION: The study suggested that the pedicle screw construction could provide better fixation stability than the locking compression plate and serves as the recommended fixation method for the treatment of posterior pelvic ring injuries.


Bone Plates , Finite Element Analysis , Fracture Fixation, Internal , Pedicle Screws , Pelvic Bones , Humans , Pelvic Bones/injuries , Pelvic Bones/surgery , Biomechanical Phenomena , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Tomography, X-Ray Computed , Fractures, Bone/surgery
8.
BMC Musculoskelet Disord ; 25(1): 343, 2024 May 01.
Article En | MEDLINE | ID: mdl-38693479

PURPOSE: To explore whether it is necessary to put drain tubes after posterior pedicle screw fixation of thoracolumbar fractures. METHODS: From April 2020 to January 2023, a total of 291 patients with recent thoracolumbar fractures (AO type-A or type-B) who received the pedicle screw fixation operation were enrolled retrospectively. In 77 patients, drain tubes were used in the pedicle screw fixation surgery, while no drain tubes were placed in the other group. After gleaning demographic information and results of lab examination and imageology examination, all data were put into a database. Independent-sample t-tests, Pearson Chi-Square tests, Linear regression analysis, and correlation analysis were then performed. RESULTS: Compared to the control group, the drainage group had significantly lower postoperative CRP levels (P = 0.047), less use of antipyretics (P = 0.035), higher ADL scores (P = 0.001), and lower NRS scores (P < 0.001) on the 6th day after surgery. Other investigation items, such as demographic information, operation time, intraoperative blood loss, body temperature, and other preoperative and postoperative lab results, showed no significant differences. CONCLUSIONS: The use of a drain tube in the pedicle screw fixation of thoracolumbar fractures is correlated with the improvement of patients' living and activity ability and the reduction of inflammation, postoperative fever and pain.


Drainage , Fracture Fixation, Internal , Lumbar Vertebrae , Pedicle Screws , Spinal Fractures , Thoracic Vertebrae , Humans , Male , Thoracic Vertebrae/surgery , Thoracic Vertebrae/injuries , Spinal Fractures/surgery , Spinal Fractures/diagnostic imaging , Lumbar Vertebrae/surgery , Lumbar Vertebrae/injuries , Female , Retrospective Studies , Adult , Middle Aged , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/adverse effects , Drainage/instrumentation , Drainage/methods , Treatment Outcome , Aged
9.
Med Eng Phys ; 128: 104169, 2024 Jun.
Article En | MEDLINE | ID: mdl-38789212

Despite the fact that lower back pain caused by degenerative lumbar spine pathologies seriously affects the quality of life, however, there is a paucity of research on the biomechanical properties of different auxiliary fixation systems for its primary treatment (oblique lumbar interbody fusion) under vibratory environments. In order to study the effects of different fixation systems of OLIF surgery on the vibration characteristics of the human lumbar spine under whole-body vibration (WBV), a finite element (FE) model of OLIF surgery with five different fixation systems was established by modifying a previously established model of the normal lumbar spine (L1-S1). In this study, a compressive follower load of 500 N and a sinusoidal axial vertical load of ±40 N at the frequency of 5 Hz with a duration of 0.6 s was applied. The results showed that the bilateral pedicle screw fixation model had the highest resistance to cage subsidence and maintenance of disc height under WBV. In contrast, the lateral plate fixation model exerted very high stresses on important tissues, which would be detrimental to the patient's late recovery and reduction of complications. Therefore, this study suggests that drivers and related practitioners who are often in vibrating environments should have bilateral pedicle screws for OLIF surgery, and side plates are not recommended to be used as a separate immobilization system. Additionally, the lateral plate is not recommended to be used as a separate fixation system.


Finite Element Analysis , Lumbar Vertebrae , Spinal Fusion , Vibration , Spinal Fusion/instrumentation , Lumbar Vertebrae/surgery , Humans , Biomechanical Phenomena , Pedicle Screws
10.
J Orthop Surg Res ; 19(1): 240, 2024 Apr 15.
Article En | MEDLINE | ID: mdl-38622736

OBJECTIVE: To assess the radiographic outcomes, clinical outcomes and complications of percutaneous kyphoplasty (PKP) with and without posterior pedicle screw fixation (PPSF) in the treatment of severe osteoporotic vertebral compression fractures (sOVCF) with nonunion. METHODS: This study involved 51 patients with sOVCF with nonunion who underwent PKP or PPSF + KP. The operation time, intraoperative blood loss, volume of injected bone cement, operation costs and hospital stays were all recorded. In addition, the Visual Analogue Scale (VAS) and the Oswestry Disability Index (ODI) were assessed separately for each patient before and after surgery. RESULTS: Compared with the PPSF + KP group, the PKP group had shorter operation time, less intraoperative blood loss, shorter hospital stays and fewer operation costs. However, cobb's angle improvement (13.4 ± 4.3° vs. 21.4 ± 5.3°), VWR improvement ratio (30.4 ± 11.5% vs. 52.8 ± 12.7%), HA (34.9 ± 9.0% vs. 63.7 ± 7.6%) and HM (28.4 ± 11.2% vs. 49.6 ± 7.7%) improvement ratio were all higher in PPSF + KP group than that in PKP group. In addition, the ODI index and VAS score in both groups were significantly decreased at the postoperative and final follow-up. PKP group's postoperative VAS score was significantly lower than that in PPSF + KP group, but there was no statistically significant difference in VAS score at the last follow-up. CONCLUSION: PKP and PPSF + KP can both effectively relieve the pain associated with sOVCF with nonunion. PPSF + KP can achieve more satisfactory vertebral reduction effects compared to PKP. However, PKP was less invasive and it has more advantages in shortening operation time and hospital stay, as well as decreasing intraoperative blood loss and operation costs.


Fractures, Compression , Kyphoplasty , Osteoporotic Fractures , Pedicle Screws , Spinal Fractures , Humans , Fractures, Compression/diagnostic imaging , Fractures, Compression/surgery , Fractures, Compression/drug therapy , Blood Loss, Surgical , Spinal Fractures/diagnostic imaging , Spinal Fractures/surgery , Spinal Fractures/drug therapy , Treatment Outcome , Osteoporotic Fractures/diagnostic imaging , Osteoporotic Fractures/surgery , Osteoporotic Fractures/drug therapy , Bone Cements/therapeutic use , Retrospective Studies
11.
Neurol Res ; 46(5): 426-436, 2024 May.
Article En | MEDLINE | ID: mdl-38557428

OBJECTIVE: Pedicle screw stabilization (PSS) surgeries for spinal instability are still the most effective treatment approach. The use of preoperative planning can minimize the complications related to transpedicular screw (TPS) misplacement. The study aimed to evaluate the surgical outcomes of a guide device developed to improve the accuracy of the free-hand technique using three-dimensional planning in PSS. PATIENTS AND METHODS: Patients with degenerative spinal diseases who underwent open PSS between 2019 and 2022 were evaluated retrospectively. FG group included patients who were operated on using the fluoroscopy alone with preoperative two-dimensional planning. AFG group included patients who were operated on using a guide advice-assisted technique with preoperative 3DP. Between-group comparisons were performed. RESULTS: A total of 143 patients with a mean age of 59.6 years were included in the study. 71 patients were assessed in the FG group and 72 patients in the AFG group. Between-group comparisons regarding demographics, etiologies, radiation exposure, and functional improvements showed no significant differences (p > 0.05). Although the accuracy of TPSs positioning was 94.2% and 96.5% in the 2DG and 3DG, the difference between the groups was not statistically significant. The statistically significant differences regarding the upper-level facet joint violation and pedicle breach rates were lower in the AFG group (p < 0.0001; X2 = 19.57) and (p < 0.0001; X2 = 25.3), respectively. CONCLUSION: Using a guide device associated with preoperative 3PD reduced the upper-level facet joint violation and pedicle breach rates in open PSS surgeries performed by free-hand technique for degenerative spinal diseases.


Lumbar Vertebrae , Pedicle Screws , Humans , Middle Aged , Male , Female , Retrospective Studies , Lumbar Vertebrae/surgery , Lumbar Vertebrae/diagnostic imaging , Aged , Imaging, Three-Dimensional/methods , Preoperative Care/methods , Preoperative Care/instrumentation , Adult , Spinal Fusion/methods , Spinal Fusion/instrumentation , Treatment Outcome , Surgery, Computer-Assisted/methods , Surgery, Computer-Assisted/instrumentation , Fluoroscopy/methods
12.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 466-473, 2024 Apr 15.
Article Zh | MEDLINE | ID: mdl-38632068

Objective: To investigate the effectiveness of injured vertebra fixation with inclined-long pedicle screws combined with interbody fusion for thoracolumbar fracture dislocation with disc injury. Methods: Between January 2017 and June 2022, 28 patients with thoracolumbar fracture dislocation with disc injury were underwent posterior depression, the injured vertebra fixation with inclined-long pedicle screws, and interbody fusion. There were 22 males and 6 females, with a mean age of 41.4 years (range, 22-58 years). The causes of injury included falling from height in 18 cases, traffic accident in 5 cases, and bruise in 5 cases. Fracture segment included 1 case of T 11, 7 cases of T 12, 9 cases of L 1, and 11 cases of L 2. According to the American Spinal Injury Association (ASIA) scale, the spinal injuries were graded as grade A in 4 cases, grade B in 2 cases, grade C in 11 cases, and grade D in 11 cases. Preoperative spinal canal encroachment ratio was 17.7%-75.3% (mean, 44.0%); the thoracolumbar injury classification and severity score (TLICS) ranged from 9 to 10 (mean, 9.9). Seventeen patients were associated with other injuries. The time from injury to operation ranged from 1 to 4 days (mean, 2.3 days). The perioperative indicators (operation time, intraoperative blood loss, and the occurrence of complications), clinical evaluation indicators [visual analogue scale (VAS) score and Oswestry Disability Index (ODI)], radiologic evaluation indicators [anterior vertebral height ratio (AVHR), kyphosis Cobb angle (KCA), intervertebral space height (ISH), vertebral wedge angle (VWA), displacement angle (DA), and percent fracture dislocation displacement (PFDD)], neurological function, and interbody fusion were recorded. Results: The operation time was 110-159 minutes (mean, 130.2 minutes). The intraoperative blood loss was 200-510 mL (mean, 354.3 mL). All incisions healed by first intention, and no surgical complications such as wound infection or hematoma occurred. All patients were followed up 12-15 months (mean, 12.7 months). The chest and lumbar pain significantly relieved, VAS scores and ODI after operation were significantly lower than those before operation, and further decreased with the extension of postoperative time, with significant differences ( P<0.05). At last follow-up, the ASIA classification of neurological function of the patients was grade A in 3 cases, grade B in 1 case, grade C in 1 case, grade D in 10 cases, and grade E in 13 cases, which was significantly different from preoperative one ( Z=-4.772, P<0.001). Imaging review showed that AVHR, KCA, ISH, VWA, DA, and PFDD significantly improved at 1 week, 3 months and last follow-up ( P<0.05). There was no significant difference between different time points after operation ( P>0.05). At last follow-up, according to the modified Brantigan score, all patients achieved good intervertebral bone fusion, including 22 complete fusion and 6 good intervertebral fusion with a few clear lines. No complications such as internal fixation failure or kyphosis occurred during follow-up. Conclusion: The injured vertebra fixation with inclined-long pedicle screws combined with interbody fusion is an effective treatment for thoracolumbar fracture dislocation with disc injury, which can correct the fracture dislocation, release the nerve compression, restore the injured vertebral height, and reconstruct spinal stabilization.


Fracture Dislocation , Fractures, Bone , Kyphosis , Pedicle Screws , Spinal Fractures , Male , Female , Humans , Adult , Blood Loss, Surgical , Lumbar Vertebrae/surgery , Spinal Fractures/surgery , Thoracic Vertebrae/surgery , Fracture Fixation, Internal/methods , Treatment Outcome , Retrospective Studies
13.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 55(2): 303-308, 2024 Mar 20.
Article Zh | MEDLINE | ID: mdl-38645868

Objective: To compare the clinical effects of cortical bone trajectory screws and traditional pedicle screws in posterior lumbar fusion. Methods: A retrospective study was conducted to analyze lumbar degeneration patients who underwent surgical treatment at our hospital between January 2016 and January 2019. A total of 123 patients who met the inclusion criteria were enrolled. The subjects were divided into two groups according to their surgical procedures and the members of the two groups were matched by age, sex, and the number of fusion segments. There were 63 patients in the traditional pedicle screws (PS) group and 60 in the cortical bone trajectory screws (CBTS) group. The outcomes of the two groups were compared. The primary outcome measures were perioperative conditions, including operation duration, estimated intraoperative blood loss (EBL), and length-of-stay (LOS), visual analog scale (VAS) score, Oswestry Disability Index (ODI) score, and interbody fusion rate. The secondary outcome measures were the time to postoperative ambulation and the incidence of complications. VAS scores and ODI scores were assessed before operation, 1 week, 1 month, 3 months, and 12 months after operation, and at the final follow-up. The interbody fusion rate was assessed in 1 year and 2 years after the operation and at the final follow-up. Results: The CBTS group showed a reduction in operation duration ([142.8±13.1] min vs. [174.7±15.4] min, P<0.001), LOS ([9.5±1.5] d vs. [12.0±2.0] d, P<0.001), and EBL ([194.2±38.3] mL vs. [377.5±33.1] mL, P<0.001) in comparison with the PS group. The VAS score for back pain in the CBTS group was lower than that in the PS group at 1 week and 1 month after operation and the ODI score in the CBTS group was lower than that in the PS group at 1 month after operation, with the differences being statistically significant (P<0.05). At each postoperative time point, the VAS score for leg pain and the interbody fusion rate did not show significant difference between the two groups. The VAS score for back and leg pain and the ODI score at each time point after operation in both the CBTS group and the PS group were significantly lower than those before operation (P<0.05). No significant difference was found in the time to postoperative ambulation or the overall complication incidence between the two groups. Conclusion: The CBTS technique could significantly shorten the operation duration and LOS, reduce EBL, and achieve the same effect as the PS technique does in terms of intervertebral fusion rate, pain relief, functional improvement, and complication incidence in patients undergoing posterior lumbar fusion.


Cortical Bone , Lumbar Vertebrae , Pedicle Screws , Spinal Fusion , Humans , Spinal Fusion/methods , Spinal Fusion/instrumentation , Lumbar Vertebrae/surgery , Retrospective Studies , Male , Female , Cortical Bone/surgery , Operative Time , Length of Stay , Middle Aged , Treatment Outcome , Intervertebral Disc Degeneration/surgery , Bone Screws , Blood Loss, Surgical/statistics & numerical data
14.
Sci Rep ; 14(1): 9272, 2024 04 23.
Article En | MEDLINE | ID: mdl-38653756

The transpedicular procedure has been widely used in spinal surgery. The determination of the best entry point is the key to perform a successful transpedicular procedure. Various techniques have been used to determine this point, but the results are variable. This study was carried out to determine the posterior endpoint of the lumbar pedicle central axis on the standard anterior-posterior (AP) fluoroscopic images. Computer-aided design technology was used to determine the pedicle central axis and the posterior endpoint of the pedicle central axis on the posterior aspect of the vertebra. The standard AP fluoroscopic image of the lumbar vertebral models by three-dimensional printing was achieved. The endpoint projection on the AP fluoroscopic image was determined in reference to the pedicle cortex projection by the measurements of the angle and distance on the established X-Y coordinate system of the radiologic image. The projection of posterior endpoint of the lumbar pedicle central axis were found to be superior to the X-axis of the established X-Y coordinate system and was located on the pedicle cortex projection on the standard AP fluoroscopic image of the vertebra. The projection point was distributed in different sectors in the coordinate system. It was located superior to the X-axis by 18° to 26° at L1, while they were located superior to the X-axis by 12° to 14° at L2 to L5. The projections of posterior endpoints of the lumbar pedicle central axis were located in different positions on the standard AP fluoroscopic image of the vertebra. The determination method of the projection point was helpful for selecting an entry point for a transpedicular procedure with a fluoroscopic technique.


Lumbar Vertebrae , Pedicle Screws , Lumbar Vertebrae/surgery , Lumbar Vertebrae/diagnostic imaging , Fluoroscopy/methods , Humans , Male , Female , Spinal Fusion/methods , Printing, Three-Dimensional , Computer-Aided Design
17.
Medicine (Baltimore) ; 103(16): e37885, 2024 Apr 19.
Article En | MEDLINE | ID: mdl-38640290

RATIONALE: Aggressive vertebral hemangiomas (AVHs) destroy continuous vertebral bodies and intervertebral discs and resulting in spinal kyphosis is extremely rare. The very aggressive behavior was attributable to its significant vascular component and contained no adipose tissue. PATIENT CONCERNS: We report a case of thoracic spine kyphosis of AVHs with multiple vertebral bodies and intervertebral disc destruction in a 45-year-old woman. DIAGNOSES: Based on the imaging studies, the patient underwent surgical removal of this lesion and spinal reconstruction. Histopathology consistent with vertebral hemangioma and contained no adipose. INTERVENTIONS: The patient underwent surgical removal of the lesion and spinal reconstruction. After subperiosteal dissection of the paraspinal muscles and exposure of the laminae, the laminae of the T5-7 vertebrae were removed and exposing the lesion. The lesion was soft and showed cystic changes, completely curetted and autogenous bone was implanted. Vertebroplasty was performed through T3-T9 pedicles bilaterally. Pedicle screw fixation was performed for segmental fixation and fusion. OUTCOMES: After 9 days of operation, the incision healed cleanly and free of pain. She was discharged in good general condition. The patient remained asymptomatic after follow-up 6 months of postoperative. LESSONS: AVHs destroy multiple vertebral bodies and intervertebral discs and resulting in spinal kyphosis is extremely rare.


Hemangioma , Kyphosis , Pedicle Screws , Spinal Fractures , Female , Humans , Middle Aged , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/surgery , Kyphosis/etiology , Kyphosis/surgery , Thoracic Vertebrae/diagnostic imaging , Thoracic Vertebrae/surgery , Thoracic Vertebrae/injuries , Hemangioma/complications , Hemangioma/surgery , Hemangioma/pathology , Treatment Outcome , Spinal Fractures/surgery
18.
J Robot Surg ; 18(1): 150, 2024 Apr 02.
Article En | MEDLINE | ID: mdl-38564025

Pedicle screw placement (PSP) is the fundamental surgical technique that requires high accuracy for novice orthopedists studying spinal oncology education. Therefore, we set forth to establish a computer-assisted robotic navigation training program for novice spinal oncology education. Novice orthopedists were involved in this study to evaluate the feasibility and safety of the computer-assisted robotic navigation (CARN) training program. In this research, trainees were randomly taught by the CARN training program and the traditional training program. We prospectively collected the clinical data of patients with spinal tumors from 1st May 2021 to 1st March 2022. The ability of PSP was evaluated by cumulative sum (CUSUM) analysis, learning curve, and accuracy of pedicle screws. The patients included in both groups had similar baseline characteristics. In the CUSUM analysis of the learning curve for accurate PSP, the turning point in the CARN group was lower than that in the traditional group (70th vs. 92nd pedicle screw). The LC-CUSUM test indicated competency for PSP at the 121st pedicle screw in the CARN group and the 138th pedicle screw in the traditional group. The accuracy of PSP was also significantly higher in the CARN group than in the traditional group (88.17% and 79.55%, P = 0.03 < 0.05). Furthermore, no major complications occurred in either group. We first described CARN in spinal oncology education and indicated the CARN training program as a novel, efficient and safe training program for surgeons.


Pedicle Screws , Robotic Surgical Procedures , Surgeons , Humans , Robotic Surgical Procedures/methods , Learning Curve , Computers
19.
Vet Surg ; 53(4): 648-658, 2024 May.
Article En | MEDLINE | ID: mdl-38532254

OBJECTIVE: To describe the clinical outcomes for pugs and French bulldogs with congenital vertebral malformations, undergoing thoracolumbar spinal stabilization surgery using 3D-printed patient-specific drill guides. To evaluate the accuracy of pedicle screw placement in this group of dogs. STUDY DESIGN: Retrospective descriptive study. ANIMALS: Twenty dogs (12 pugs and eight French bulldogs). METHODS: Medical records searched between August 2018 and March 2021 for pugs and French bulldogs diagnosed with congenital vertebral abnormalities via magnetic resonance imaging (MRI) scan and computed tomography (CT) scan causing T3-L3 myelopathy signs that underwent spinal stabilization surgery using 3D-printed patient-specific drill guides followed by a postoperative CT scan. The short-term outcome was based on the neurological grade (modified Frankel score-MFS) on the day after surgery, day of discharge, and at the follow-up examination at 4 to 6 weeks after surgery. The mid-term outcome was obtained via an online questionnaire (or direct examination in one case). RESULTS: Twenty dogs met the inclusion criteria (19/20 grade 2 MFS, 1/20 grade 4 MFS). No complications were reported in the immediate postoperative period and optimal pedicle screw placement was obtained in 169/201 of screws. Twenty-four hours after surgery 16/20 dogs displayed an unchanged neurological grade. Short-term outcomes revealed a static (17/20) or improved (2/20) neurological grade. Ten owners participated in the online questionnaire. All patients were reported to be ambulatory; however, 7/10 dogs displayed abnormal gait. Neurological signs had remained static (6/10) or improved (3/10) in comparison with the dogs' preoperative status at a median of 883.5 days from the surgery. CONCLUSION: Dogs in this study had a favorable short-term outcome and mid-term outcome evaluation revealed a static/improved neurological status. CLINICAL SIGNIFICANCE: Thoracolumbar spinal stabilization surgery using 3D-printed patient-specific drill guides showed a favorable outcome in brachycephalic breeds affected by vertebral deformities.


Dog Diseases , Printing, Three-Dimensional , Thoracic Vertebrae , Animals , Dogs , Retrospective Studies , Dog Diseases/surgery , Dog Diseases/diagnostic imaging , Male , Female , Thoracic Vertebrae/surgery , Thoracic Vertebrae/abnormalities , Treatment Outcome , Pedicle Screws , Lumbar Vertebrae/surgery , Lumbar Vertebrae/abnormalities , Tomography, X-Ray Computed/veterinary
20.
Sci Rep ; 14(1): 6487, 2024 03 18.
Article En | MEDLINE | ID: mdl-38499611

The objective is to compare the clinical efficacy and safety of the S8 navigation system and the Tinavi orthopaedic surgery robot in the treatment of upper cervical instability. The research methods adopted are as follows. The clinical data of patients with upper cervical instability who underwent surgery from May 2021 to December 2021 were analysed retrospectively. Patients were divided into a navigation group (assisted by the S8 navigation system) and a tinavi group (assisted by the Tinavi robot) according to the auxiliary system used. Computed tomography and digital radiography were performed after the operation. The accuracy of pedicle screw placement was evaluated using the criteria put forward by Rampersaud. Degree of facet joint violation, visual analogue scale score, neck disability index and Japanese orthopaedic association score were recorded and assessed during follow-up examinations in both groups. Record two groups of surgery-related indicators. Record the complications of the two groups. A total of 50 patients were included. 21 patients in the navigation group and 29 in the tinavi group. The results of the study are as follows. The average follow-up time was 12.1 months. There was no significant difference in nail placement accuracy between the navigation and tinavi groups (P > 0.05); however, the navigation group had a significantly higher rate of facet joint violation than that of tinavi group (P < 0.05), and the screws were placed closer to the anterior cortex (P < 0.05). Significantly more intraoperative fluoroscopies were performed in the tinavi group than in the navigation group, and the operation time was significantly longer in the tinavi group than in the navigation group (P < 0.05). The time of single nail implantation, intraoperative blood loss and incision length in navigation group were significantly longer than those in tinavi group. There were no statistically significant differences in other indicators between the two groups (P > 0.05). We come to the following conclusion. The Stealth Station S8 navigation system (Medtronic, USA), which also uses an optical tracking system, and the Tinavi Orthopedic robot have shown the same high accuracy and satisfactory clinical results in the treatment of upper cervical instability. Although the S8 navigation system still has many limitations, it still has good application prospects and is a new tool for spine surgery.


Orthopedics , Pedicle Screws , Robotics , Spinal Fusion , Humans , Retrospective Studies , Treatment Outcome
...