Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 3.443
2.
Methodist Debakey Cardiovasc J ; 20(1): 33-39, 2024.
Article En | MEDLINE | ID: mdl-38855039

We report three cases of coronary artery aneurysm (CAA) in adults who presented with acute coronary syndrome. Two of these patients did not have traditional coronary artery disease risk factors. Management of CAA poses a significant challenge to interventionalists. We discuss the etiologic mechanisms, risk factors, pathophysiology, and diagnosis using angiography, intravascular ultrasound, and coronary computed tomography. We also highlight management options, including medical therapy and catheter-based interventions such as stenting, coil embolization, stent-assisted coil embolization, and surgical exclusion.


Acute Coronary Syndrome , Coronary Aneurysm , Coronary Angiography , Humans , Coronary Aneurysm/diagnostic imaging , Coronary Aneurysm/therapy , Acute Coronary Syndrome/therapy , Acute Coronary Syndrome/diagnostic imaging , Acute Coronary Syndrome/etiology , Male , Treatment Outcome , Middle Aged , Embolization, Therapeutic , Ultrasonography, Interventional , Female , Aged , Predictive Value of Tests , Stents , Percutaneous Coronary Intervention/instrumentation , Computed Tomography Angiography , Risk Factors
4.
JACC Cardiovasc Interv ; 17(9): 1106-1115, 2024 May 13.
Article En | MEDLINE | ID: mdl-38749590

BACKGROUND: Unintended deformation of implanted coronary stents can lead to loss of coronary access, stent thrombosis and coronary events during follow-up. The incidence, mechanisms and clinical outcomes of unintended stent deformations (USD) during complex bifurcation stenting are not well characterized. OBJECTIVES: In a prespecified analysis of the OCTOBER (European Trial on Optical Coherence Tomography Optimized Bifurcation Event Reduction) trial, we aimed to: 1) determine the incidence and characterize mechanisms of USD identified by optical coherence tomography (OCT); and 2) evaluate physician's detection and correction of accidental abluminal rewiring and USD. METHODS: OCT scans were analyzed for accidental abluminal rewiring and USD. When USD was identified, the plausible mechanism was determined by analysis of all procedural OCT scans and the corresponding angiograms. RESULTS: USD was identified by the core lab in 9.3% (55/589) of OCT-guided cases. Accidental abluminal rewiring was the cause in 44% (24/55), and guide catheter collision was the cause in 40% (22/55) of cases. USD was found in 18.5% of all cases with left main bifurcation percutaneous coronary intervention. The total incidence of abluminal rewiring was 33 in 32 OCT-guided cases (5.4%) and was corrected by physicians in 18 of 33 appearances (54.5%). The 2-year major adverse cardiac event rate for patients with untreated USD (n = 30) was 23.3%, whereas patients with confirmed or possibly corrected USD (n = 25) had no events during follow-up. CONCLUSIONS: USD was associated with adverse procedural complications and cardiac events during follow-up when not identified and corrected. The predominant mechanisms were undetected abluminal rewiring and guide catheter collision. Left main bifurcation percutaneous coronary intervention was a particular risk with USD detected in 18.5% of cases.


Coronary Angiography , Coronary Artery Disease , Percutaneous Coronary Intervention , Prosthesis Design , Stents , Tomography, Optical Coherence , Humans , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/adverse effects , Treatment Outcome , Male , Female , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Middle Aged , Aged , Risk Factors , Europe , Time Factors , Prosthesis Failure , Predictive Value of Tests
9.
JACC Cardiovasc Interv ; 17(9): 1119-1130, 2024 May 13.
Article En | MEDLINE | ID: mdl-38749592

BACKGROUND: There was no study evaluating the effects of an aspirin-free strategy in patients undergoing complex percutaneous coronary intervention (PCI). OBJECTIVES: The authors aimed to evaluate the efficacy and safety of an aspirin-free strategy in patients undergoing complex PCI. METHODS: We conducted the prespecified subgroup analysis based on complex PCI in the STOPDAPT-3 (ShorT and OPtimal duration of Dual AntiPlatelet Therapy after everolimus-eluting cobalt-chromium stent-3), which randomly compared low-dose prasugrel (3.75 mg/d) monotherapy to dual antiplatelet therapy (DAPT) with low-dose prasugrel and aspirin in patients with acute coronary syndrome or high bleeding risk. Complex PCI was defined as any of the following 6 criteria: 3 vessels treated, ≥3 stents implanted, ≥3 lesions treated, bifurcation with 2 stents implanted, total stent length >60 mm, or a target of chronic total occlusion. The coprimary endpoints were major bleeding events (Bleeding Academic Research Consortium 3 or 5) and cardiovascular events (a composite of cardiovascular death, myocardial infarction, definite stent thrombosis, or ischemic stroke) at 1 month. RESULTS: Of the 5,966 study patients, there were 1,230 patients (20.6%) with complex PCI. Regardless of complex PCI, the effects of no aspirin relative to DAPT were not significant for the coprimary bleeding (complex PCI: 5.30% vs 3.70%; HR: 1.44; 95% CI: 0.84-2.47; P = 0.18 and noncomplex PCI: 4.26% vs 4.97%; HR: 0.85; 95% CI: 0.65-1.11; P = 0.24; P for interaction = 0.08) and cardiovascular (complex PCI: 5.78% vs 5.93%; HR: 0.98; 95% CI: 0.62-1.55; P = 0.92 and noncomplex PCI: 3.70% vs 3.10%; HR: 1.20; 95% CI: 0.88-1.63; P = 0.25; P for interaction = 0.48) endpoints without significant interactions. CONCLUSIONS: The effects of the aspirin-free strategy relative to standard DAPT for the cardiovascular and major bleeding events were not different regardless of complex PCI. (ShorT and OPtimal duration of Dual AntiPlatelet Therapy after everolimus-eluting cobalt-chromium stent-3 [STOPDAPT-3]; NCT04609111).


Aspirin , Coronary Artery Disease , Drug Administration Schedule , Drug-Eluting Stents , Dual Anti-Platelet Therapy , Everolimus , Hemorrhage , Percutaneous Coronary Intervention , Platelet Aggregation Inhibitors , Prasugrel Hydrochloride , Prosthesis Design , Humans , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/mortality , Platelet Aggregation Inhibitors/adverse effects , Platelet Aggregation Inhibitors/administration & dosage , Male , Time Factors , Female , Aspirin/administration & dosage , Aspirin/adverse effects , Aspirin/therapeutic use , Aged , Middle Aged , Treatment Outcome , Hemorrhage/chemically induced , Hemorrhage/prevention & control , Risk Factors , Prasugrel Hydrochloride/administration & dosage , Prasugrel Hydrochloride/adverse effects , Prasugrel Hydrochloride/therapeutic use , Everolimus/administration & dosage , Everolimus/adverse effects , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Thrombosis/etiology , Coronary Thrombosis/prevention & control , Acute Coronary Syndrome/therapy , Acute Coronary Syndrome/diagnostic imaging , Chromium Alloys , Risk Assessment , Drug Therapy, Combination
11.
Scand Cardiovasc J ; 58(1): 2347295, 2024 Dec.
Article En | MEDLINE | ID: mdl-38706409

Objectives. This study investigated the influence of higher pressure protection with a small diameter balloon of side branch (SB) on bifurcation lesions. Background. Of the different coronary stent implantation techniques, the modified jailed balloon technique has become a viable option for bifurcation lesions. However, there was no detailed study on the relationship between the balloon inflation pressure of the main vessel (MV) and SB. Methods. In this study, we collected information of patients who underwent percutaneous coronary intervention (PCI) for bifurcated lesions between March 2019 and December 2022. They were divided into two groups according to the operation way: active jailed balloon technique (A-JBT) group and jailed wire technique (JWT) group. Results. A total of 216 patients were enrolled. The A-JBT group had a larger SB stenosis diameter (1.53 ± 0.69 vs. 0.95 ± 0.52, p < .001), the lower degree of stenosis (44.34 ± 18.30 vs. 63.69 ± 17.34, p < .001) compared to the JWT group. However, the JWT group had a higher incidence of SB occlusion (18.0% vs. 1.9%, p < .001) compared to the A-JBT group. Nevertheless, the success rate for both groups was 100%. Conclusions. This novel high inflation pressure and small diameter balloon approach we propose has significant advantages. There is a lower rate of SB occlusion and SB dissection, which is more cost-effective and provides better clinical outcomes for the patient. This method should be considered in the future for treating bifurcation lesions.


Angioplasty, Balloon, Coronary , Cardiac Catheters , Coronary Artery Disease , Humans , Male , Female , Aged , Middle Aged , Treatment Outcome , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/adverse effects , Retrospective Studies , Stents , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/therapy , Coronary Stenosis/surgery , Risk Factors , Pressure , Time Factors , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation
12.
JACC Cardiovasc Interv ; 17(10): 1187-1199, 2024 May 27.
Article En | MEDLINE | ID: mdl-38811101

Calcified nodules (CNs) are among the most challenging lesions to treat in contemporary percutaneous coronary intervention. CNs may be divided into 2 subtypes, eruptive and noneruptive, which have distinct histopathological and prognostic features. An eruptive CN is a biologically active lesion with a disrupted fibrous cap and possibly adherent thrombus, whereas a noneruptive CN has an intact fibrous cap and no adherent thrombus. The use of intravascular imaging may allow differentiation between the 2 subtypes, thus potentially guiding treatment strategy. Compared with noneruptive CNs, eruptive CNs are more likely to be deformable, resulting in better stent expansion, but are paradoxically associated with worse clinical outcomes, in part because of their frequent initial presentation as an acute coronary syndrome and subsequent reprotrusion of the CN into the vessel lumen through the stent struts. Pending the results of ongoing studies, a tailored therapeutic approach based on the distinct features of the different CNs may be of value.


Coronary Artery Disease , Percutaneous Coronary Intervention , Stents , Vascular Calcification , Humans , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/adverse effects , Vascular Calcification/diagnostic imaging , Vascular Calcification/therapy , Treatment Outcome , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Risk Factors , Predictive Value of Tests , Coronary Vessels/diagnostic imaging , Plaque, Atherosclerotic , Ultrasonography, Interventional , Coronary Angiography , Clinical Decision-Making
14.
JACC Cardiovasc Interv ; 17(10): 1231-1243, 2024 May 27.
Article En | MEDLINE | ID: mdl-38811104

BACKGROUND: It is unclear whether the beneficial effects of intravascular imaging-guided stent optimization vary by clinical presentation during complex percutaneous coronary intervention (PCI). OBJECTIVES: In this prespecified, stratified subgroup analysis from RENOVATE-COMPLEX-PCI (Randomized Controlled Trial of Intravascular Imaging Guidance versus Angiography-Guidance on Clinical Outcomes After Complex PCI), we sought to compare the outcomes between intravascular imaging vs angiography guidance according to clinical presentation. METHODS: Patients with complex coronary artery lesions were randomly assigned to undergo either intravascular imaging-guided PCI or angiography-guided PCI in a 2:1 ratio. The primary endpoint was target vessel failure (TVF), which is a composite of cardiac death, target vessel-related myocardial infarction, or clinically driven target vessel revascularization. RESULTS: Of 1,639 patients, 832 (50.8%) presented with acute coronary syndrome (ACS) and 807 (49.2%) with chronic coronary syndrome. During a median follow-up of 2.1 years (Q1-Q3: 1.4-3.0 years), there was no significant interaction between the treatment effect of intravascular imaging and clinical presentation (P for interaction = 0.19). Among patients with ACS, the incidences of TVF were 10.4% in the intravascular imaging group and 14.6% in the angiography group (HR: 0.74; 95% CI: 0.48-1.15; P = 0.18). Among patients with CCS, the incidences of TVF were 5.0% in the intravascular imaging group and 10.4% in the angiography group (HR: 0.46; 95% CI: 0.27-0.80; P = 0.006). Achieving stent optimization by intravascular imaging resulted in a reduced risk of TVF among patients with ACS who were randomly assigned to intravascular imaging-guided PCI for complex coronary lesions (optimized vs unoptimized, 6.5% vs 14.1%; HR: 0.49; 95% CI: 0.27-0.87; P = 0.02) but not those with CCS (5.4% vs 4.7%, HR: 1.18; 95% CI: 0.53-2.59; P = 0.69). CONCLUSIONS: No significant interaction was observed between the benefits of intravascular imaging and clinical presentation in the risk of TVF. Stent optimization by intravascular imaging was particularly important for ACS patients. (Intravascular Imaging- Versus Angiography-Guided Percutaneous Coronary Intervention For Complex Coronary Artery Disease [RENOVATE]; NCT03381872).


Acute Coronary Syndrome , Coronary Angiography , Coronary Artery Disease , Percutaneous Coronary Intervention , Predictive Value of Tests , Stents , Humans , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Male , Female , Aged , Middle Aged , Treatment Outcome , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Artery Disease/mortality , Time Factors , Risk Factors , Acute Coronary Syndrome/diagnostic imaging , Acute Coronary Syndrome/therapy , Ultrasonography, Interventional , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/etiology , Chronic Disease
17.
EuroIntervention ; 20(10): e669-e680, 2024 May 20.
Article En | MEDLINE | ID: mdl-38776143

BACKGROUND: Compared with thin-strut durable-polymer drug-eluting stents (DP-DES), ultrathin-strut biodegradable-polymer sirolimus-eluting stents (BP-SES) improve stent-related clinical outcomes in patients undergoing percutaneous coronary intervention (PCI). Reduced stent strut thickness is hypothesised to underlie these benefits, but this conjecture remains unproven. AIMS: We aimed to assess the impact of strut thickness on stent healing and clinical outcomes between ultrathin-strut and thin-strut BP-SES. METHODS: First, we performed a preclinical study of 8 rabbits implanted with non-overlapping thin-strut (diameter/thickness 3.5 mm/80 µm) and ultrathin-strut (diameter/thickness 3.0 mm/60 µm) BP-SES in the infrarenal aorta. On day 7, the rabbits underwent intravascular near-infrared fluorescence optical coherence tomography (NIRF-OCT) molecular-structural imaging of fibrin deposition and stent tissue coverage, followed by histopathological analysis. Second, we conducted an individual data pooled analysis of patients enrolled in the BIOSCIENCE and BIOSTEMI randomised PCI trials treated with ultrathin-strut (n=282) or thin-strut (n=222) BP-SES. The primary endpoint was target lesion failure (TLF) at 1-year follow-up, with a landmark analysis at 30 days. RESULTS: NIRF-OCT image analyses revealed that ultrathin-strut and thin-strut BP-SES exhibited similar stent fibrin deposition (p=0.49) and percentage of uncovered stent struts (p=0.63). Histopathological assessments corroÂborated these findings. In 504 pooled randomised trial patients, TLF rates were similar for those treated with ultrathin-strut or thin-strut BP-SES at 30-day (2.5% vs 1.8%; p=0.62) and 1-year follow-up (4.3% vs 4.7%; p=0.88). CONCLUSIONS: Ultrathin-strut and thin-strut BP-SES demonstrate similar early arterial healing profiles and 30-day and 1-year clinical outcomes.


Drug-Eluting Stents , Percutaneous Coronary Intervention , Sirolimus , Tomography, Optical Coherence , Animals , Rabbits , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/methods , Humans , Sirolimus/therapeutic use , Sirolimus/administration & dosage , Sirolimus/pharmacology , Treatment Outcome , Prosthesis Design , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Male , Absorbable Implants , Female , Wound Healing
18.
EuroIntervention ; 20(10): e630-e642, 2024 May 20.
Article En | MEDLINE | ID: mdl-38776146

BACKGROUND: A short dual antiplatelet therapy (DAPT) duration has been proposed for patients at high bleeding risk (HBR) undergoing drug-eluting coronary stent (DES) implantation. Whether this strategy is safe and effective after a non-ST-segment elevation acute coronary syndrome (NSTE-ACS) remains uncertain. AIMS: We aimed to compare the impact of 1-month versus 3-month DAPT on clinical outcomes after DES implantation among HBR patients with or without NSTE-ACS. METHODS: This is a prespecified analysis from the XIENCE Short DAPT programme involving three prospective, international, single-arm studies evaluating the safety and efficacy of 1-month (XIENCE 28 USA and Global) or 3-month (XIENCE 90) DAPT among HBR patients after implantation of a cobalt-chromium everolimus-eluting stent. Ischaemic and bleeding outcomes associated with 1- versus 3-month DAPT were assessed according to clinical presentation using propensity score stratification. RESULTS: Of 3,364 HBR patients (1,392 on 1-month DAPT and 1,972 on 3-month DAPT), 1,164 (34.6%) underwent DES implantation for NSTE-ACS. At 12 months, the risk of the primary endpoint of death or myocardial infarction was similar between 1- and 3-month DAPT in patients with (hazard ratio [HR] 1.09, 95% confidence interval [CI]: 0.71-1.65) and without NSTE-ACS (HR 0.88, 95% CI: 0.63-1.23; p-interaction=0.34). The key secondary endpoint of Bleeding Academic Research Consortium (BARC) Type 2-5 bleeding was consistently reduced in both NSTE-ACS (HR 0.57, 95% CI: 0.37-0.88) and stable patients (HR 0.84, 95% CI: 0.61-1.15; p-interaction=0.15) with 1-month DAPT. CONCLUSIONS: Among HBR patients undergoing implantation of an everolimus-eluting stent, 1-month, compared to 3-month DAPT, was associated with similar ischaemic risk and reduced bleeding at 1 year, irrespective of clinical presentation.


Acute Coronary Syndrome , Drug-Eluting Stents , Dual Anti-Platelet Therapy , Hemorrhage , Percutaneous Coronary Intervention , Platelet Aggregation Inhibitors , Humans , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Percutaneous Coronary Intervention/instrumentation , Acute Coronary Syndrome/therapy , Platelet Aggregation Inhibitors/therapeutic use , Platelet Aggregation Inhibitors/adverse effects , Platelet Aggregation Inhibitors/administration & dosage , Male , Middle Aged , Aged , Female , Hemorrhage/chemically induced , Treatment Outcome , Dual Anti-Platelet Therapy/methods , Prospective Studies , Time Factors , Risk Factors , Non-ST Elevated Myocardial Infarction/therapy , Non-ST Elevated Myocardial Infarction/mortality
20.
BMC Cardiovasc Disord ; 24(1): 262, 2024 May 20.
Article En | MEDLINE | ID: mdl-38769510

BACKGROUND: Optical coherence tomography (OCT) guidance in percutaneous coronary intervention (PCI) has been shown to improve procedural outcomes. However, evidence supporting its superiority over angiography-guided PCI in terms of clinical outcomes is still emerging and limited. This study aimed to compare the efficacy and safety of OCT-guided PCI versus angiography-guided PCI in patients with coronary artery disease (CAD). METHODS: A systematic search of electronic databases was conducted to identify randomized control trials (RCTs) comparing the clinical outcomes of OCT-guided and angiography-guided PCI in patients with CAD. Clinical endpoints including all-cause mortality, myocardial infarction (MI), target lesion revascularization (TLR), stent thrombosis and major adverse cardiac events (MACE) were assessed. RESULTS: Eleven RCTs, comprising 2,699 patients in the OCT-guided group and 2,968 patients in the angiography-guided group met inclusion criteria. OCT-guided PCI was associated with significantly lower rates of cardiovascular death(RR 0.56; 95%CI: 0.32-0.98; p = 0.04; I2 = 0%), stent thrombosis(RR 0.56; 95%CI: 0.33-0.95; p = 0.03; I2 = 0%), and MACE (RR 0.79; 95%CI: 0.66-0.95; p = 0.01; I2 = 5%). The incidence of all-cause death (RR 0.71; 95%CI: 0.49-1.02; p = 0.06; I2 = 0%), myocardial infarction (RR 0.86; 95%CI: 0.67-1.10; p = 0.22; I2 = 0%) and TLR (RR 0.98; 95%CI: 0.73-1.33; p = 0.91; I2 = 0%) was non-significantly lower in the OCT-guided group. CONCLUSIONS: Among patients undergoing PCI, OCT-guided PCI was associated with lower incidences of cardiovascular death, stent thrombosis and MACE compared to angiography-guided PCI. TRIAL REGISTRATION: PROSPERO registration number: CRD42023484342.


Coronary Angiography , Coronary Artery Disease , Percutaneous Coronary Intervention , Predictive Value of Tests , Randomized Controlled Trials as Topic , Tomography, Optical Coherence , Humans , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/mortality , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Artery Disease/therapy , Treatment Outcome , Risk Factors , Male , Female , Middle Aged , Aged , Coronary Vessels/diagnostic imaging , Coronary Thrombosis/diagnostic imaging , Coronary Thrombosis/etiology
...