Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 489
Filter
1.
J Biomed Opt ; 29(8): 080801, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39143981

ABSTRACT

Significance: Photoacoustic imaging (PAI) is an emerging technology that holds high promise in a wide range of clinical applications, but standardized methods for system testing are lacking, impeding objective device performance evaluation, calibration, and inter-device comparisons. To address this shortfall, this tutorial offers readers structured guidance in developing tissue-mimicking phantoms for photoacoustic applications with potential extensions to certain acoustic and optical imaging applications. Aim: The tutorial review aims to summarize recommendations on phantom development for PAI applications to harmonize efforts in standardization and system calibration in the field. Approach: The International Photoacoustic Standardization Consortium has conducted a consensus exercise to define recommendations for the development of tissue-mimicking phantoms in PAI. Results: Recommendations on phantom development are summarized in seven defined steps, expanding from (1) general understanding of the imaging modality, definition of (2) relevant terminology and parameters and (3) phantom purposes, recommendation of (4) basic material properties, (5) material characterization methods, and (6) phantom design to (7) reproducibility efforts. Conclusions: The tutorial offers a comprehensive framework for the development of tissue-mimicking phantoms in PAI to streamline efforts in system testing and push forward the advancement and translation of the technology.


Subject(s)
Phantoms, Imaging , Photoacoustic Techniques , Photoacoustic Techniques/instrumentation , Photoacoustic Techniques/methods , Humans , Equipment Design , Reproducibility of Results , Calibration
2.
Sci Rep ; 14(1): 18779, 2024 08 13.
Article in English | MEDLINE | ID: mdl-39138339

ABSTRACT

Freehand optical ultrasound (OpUS) imaging is an emerging ultrasound imaging paradigm that uses an array of fibre-optic, photoacoustic ultrasound sources and a single fibre-optic ultrasound detector to perform ultrasound imaging without the need for electrical components in the probe head. Previous freehand OpUS devices have demonstrated capability for real-time, video-rate imaging of clinically relevant targets, but have been hampered by poor ultrasound penetration, significant imaging artefacts and low frame rates, and their designs limited their clinical applicability. In this work we present a novel freehand OpUS imaging platform, including a fully mobile and compact acquisition console and an improved probe design. The novel freehand OpUS probe presented utilises optical waveguides to shape the generated ultrasound fields for improved ultrasound penetration depths, an extended fibre-optic bundle to improve system versatility and an overall ruggedised design with protective elements to improve probe handling and protect the internal optical components. This probe is demonstrated with phantoms and the first multi-participant in vivo imaging study conducted with freehand OpUS imaging probes, this represents several significant steps towards the clinical translation of freehand OpUS imaging.


Subject(s)
Phantoms, Imaging , Ultrasonography , Ultrasonography/methods , Ultrasonography/instrumentation , Humans , Photoacoustic Techniques/methods , Photoacoustic Techniques/instrumentation , Equipment Design , Fiber Optic Technology/instrumentation , Optical Imaging/methods , Optical Imaging/instrumentation
3.
J Biomed Opt ; 29(6): 066006, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38846677

ABSTRACT

Significance: Photoacoustic computed tomography (PACT) is a promising non-invasive imaging technique for both life science and clinical implementations. To achieve fast imaging speed, modern PACT systems have equipped arrays that have hundreds to thousands of ultrasound transducer (UST) elements, and the element number continues to increase. However, large number of UST elements with parallel data acquisition could generate a massive data size, making it very challenging to realize fast image reconstruction. Although several research groups have developed GPU-accelerated method for PACT, there lacks an explicit and feasible step-by-step description of GPU-based algorithms for various hardware platforms. Aim: In this study, we propose a comprehensive framework for developing GPU-accelerated PACT image reconstruction (GPU-accelerated photoacoustic computed tomography), to help the research community to grasp this advanced image reconstruction method. Approach: We leverage widely accessible open-source parallel computing tools, including Python multiprocessing-based parallelism, Taichi Lang for Python, CUDA, and possible other backends. We demonstrate that our framework promotes significant performance of PACT reconstruction, enabling faster analysis and real-time applications. Besides, we also described how to realize parallel computing on various hardware configurations, including multicore CPU, single GPU, and multiple GPUs platform. Results: Notably, our framework can achieve an effective rate of ∼ 871 times when reconstructing extremely large-scale three-dimensional PACT images on a dual-GPU platform compared to a 24-core workstation CPU. In this paper, we share example codes via GitHub. Conclusions: Our approach allows for easy adoption and adaptation by the research community, fostering implementations of PACT for both life science and medicine.


Subject(s)
Algorithms , Image Processing, Computer-Assisted , Phantoms, Imaging , Photoacoustic Techniques , Photoacoustic Techniques/methods , Photoacoustic Techniques/instrumentation , Image Processing, Computer-Assisted/methods , Animals , Computer Graphics , Tomography, X-Ray Computed/methods , Tomography, X-Ray Computed/instrumentation , Humans
4.
Opt Lett ; 49(11): 3054-3057, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38824326

ABSTRACT

Photoacoustic imaging (PAI) utilizes the photoacoustic effect to record both vascular and functional characteristics of a biological tissue. Photoacoustic signals have typically low amplitude that cannot be read efficiently by data acquisition systems. This necessitates the use of one or more amplifiers. These amplifiers are somewhat bulky (e.g., the ZFL-500LN+, Mini-Circuits, USA, or 351A-3-50-NI, Analog Modules Inc., USA). Here, we describe the fabrication and development process of a transducer with a built-in low-noise preamplifier that is encased within the transducer housing. This new, to the best of our knowledge, design could be advantageous for applications where a compact transducer + preamplifier is required. We demonstrate the performance of this compact detection unit in a laser scanning photoacoustic microscopy system by imaging a rat ear ex vivo and a rat brain vasculature in vivo.


Subject(s)
Equipment Design , Photoacoustic Techniques , Transducers , Photoacoustic Techniques/instrumentation , Photoacoustic Techniques/methods , Animals , Rats , Miniaturization , Brain/diagnostic imaging , Brain/blood supply , Ear/diagnostic imaging , Ear/blood supply , Amplifiers, Electronic
5.
ACS Nano ; 18(28): 18176-18190, 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-38941553

ABSTRACT

Photoacoustic computed tomography (PACT), an emerging imaging modality in preclinical cancer research, can provide multiparametric 3D information about structures, physiological functions, and pharmacokinetics. Here, we demonstrate the use of high-definition 3D multiparametric PACT imaging of both primary and metastatic tumors in living mice to noninvasively monitor angiogenesis, carcinogenesis, hypoxia, and pharmacokinetics. The high-definition PACT system with a 1024-element hemispherical ultrasound transducer array provides an isotropic spatial resolution of 380 µm, an effective volumetric field-of-view of 12.8 mm × 12.8 mm × 12.8 mm without scanning, and an acquisition time of <30 s for a whole mouse body. Initially, we monitor the structural progression of the tumor microenvironment (e.g., angiogenesis and vessel tortuosity) after tumor cell inoculation. Then, we analyze the change in oxygen saturation of the tumor during carcinogenesis, verifying induced hypoxia in the tumor's core region. Finally, the whole-body pharmacokinetics are photoacoustically imaged after intravenous injection of micelle-loaded IR780 dye, and the in vivo PACT results are validated in vivo and ex vivo by fluorescence imaging. By employing the premium PACT system and applying multiparametric analyses to subcutaneous primary tumors and metastatic liver tumors, we demonstrate that this PACT system can provide multiparametric analyses for comprehensive cancer research.


Subject(s)
Neoplasms , Photoacoustic Techniques , Female , Animals , Photoacoustic Techniques/instrumentation , Photoacoustic Techniques/methods , Tomography/instrumentation , Tomography/methods , Neoplasms/diagnostic imaging , Neoplasms/pathology , Mice, Inbred BALB C , Cell Line, Tumor , Contrast Media , Liver Neoplasms/secondary , Skin/pathology
6.
J Biophotonics ; 17(7): e202400058, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38695390

ABSTRACT

Vascular diseases are a leading cause of death and disability worldwide. Despite having precursor conditions like peripheral arterial disease (PAD), they are often only diagnosed after the onset of stroke or heart attack. Low-cost, portable, noninvasive, point-of-care (POC), label-free assessment of deep vascular function benefits PAD diagnosis, especially in resource poor settings of the world. Doppler ultrasound-based blood flow measurements can diagnose PAD, albeit with limited sensitivity and specificity. To overcome this, here, we propose the first-of-its-kind dual-modality photoacoustic-and-ultrasound (PAUS) imaging system that integrates a multiwavelength pulsed laser diode (PLD) with a compact ultrasound data acquisition unit. The mesoscopic imaging depth of the portable PLD-PAUS system was validated using tissue phantoms, and its multispectral photoacoustic imaging capabilities were validated using an atherosclerosis-mimicking phantom. Furthermore, we demonstrated high-contrast volumetric in vivo photoacoustic imaging of rodent abdominal vasculature and quantified vessel reactivity due to hypercapnia stimulation. The multiparametric functional and molecular imaging capabilities of the PLD-PAUS system holds promise for POC applications.


Subject(s)
Phantoms, Imaging , Photoacoustic Techniques , Point-of-Care Systems , Ultrasonography , Photoacoustic Techniques/instrumentation , Animals , Ultrasonography/instrumentation , Lasers, Semiconductor , Rats , Mice
7.
J Biomed Opt ; 29(Suppl 1): S11529, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38650979

ABSTRACT

Significance: Compressed sensing (CS) uses special measurement designs combined with powerful mathematical algorithms to reduce the amount of data to be collected while maintaining image quality. This is relevant to almost any imaging modality, and in this paper we focus on CS in photoacoustic projection imaging (PAPI) with integrating line detectors (ILDs). Aim: Our previous research involved rather general CS measurements, where each ILD can contribute to any measurement. In the real world, however, the design of CS measurements is subject to practical constraints. In this research, we aim at a CS-PAPI system where each measurement involves only a subset of ILDs, and which can be implemented in a cost-effective manner. Approach: We extend the existing PAPI with a self-developed CS unit. The system provides structured CS matrices for which the existing recovery theory cannot be applied directly. A random search strategy is applied to select the CS measurement matrix within this class for which we obtain exact sparse recovery. Results: We implement a CS PAPI system for a compression factor of 4:3, where specific measurements are made on separate groups of 16 ILDs. We algorithmically design optimal CS measurements that have proven sparse CS capabilities. Numerical experiments are used to support our results. Conclusions: CS with proven sparse recovery capabilities can be integrated into PAPI, and numerical results support this setup. Future work will focus on applying it to experimental data and utilizing data-driven approaches to enhance the compression factor and generalize the signal class.


Subject(s)
Algorithms , Equipment Design , Image Processing, Computer-Assisted , Photoacoustic Techniques , Photoacoustic Techniques/methods , Photoacoustic Techniques/instrumentation , Image Processing, Computer-Assisted/methods , Data Compression/methods , Phantoms, Imaging
8.
J Med Ultrason (2001) ; 51(2): 169-183, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38480548

ABSTRACT

PURPOSE: Vascular distribution is important information for diagnosing diseases and supporting surgery. Photoacoustic imaging is a technology that can image blood vessels noninvasively and with high resolution. In photoacoustic imaging, a hemispherical array sensor is especially suitable for measuring blood vessels running in various directions. However, as a hemispherical array sensor, a sparse array sensor is often used due to technical and cost issues, which causes artifacts in photoacoustic images. Therefore, in this study, we reduce these artifacts using deep learning technology to generate signals of virtual dense array sensors. METHODS: Generating 2D virtual array sensor signals using a 3D convolutional neural network (CNN) requires huge computational costs and is impractical. Therefore, we installed virtual sensors between the real sensors along the spiral pattern in three different directions and used a 2D CNN to generate signals of the virtual sensors in each direction. Then we reconstructed a photoacoustic image using the signals from both the real sensors and the virtual sensors. RESULTS: We evaluated the proposed method using simulation data and human palm measurement data. We found that these artifacts were significantly reduced in the images reconstructed using the proposed method, while the artifacts were strong in the images obtained only from the real sensor signals. CONCLUSION: Using the proposed method, we were able to significantly reduce artifacts, and as a result, it became possible to recognize deep blood vessels. In addition, the processing time of the proposed method was sufficiently applicable to clinical measurement.


Subject(s)
Artifacts , Deep Learning , Image Processing, Computer-Assisted , Photoacoustic Techniques , Photoacoustic Techniques/methods , Photoacoustic Techniques/instrumentation , Humans , Image Processing, Computer-Assisted/methods , Hand/diagnostic imaging , Hand/blood supply
9.
IEEE Trans Biomed Eng ; 70(8): 2279-2288, 2023 08.
Article in English | MEDLINE | ID: mdl-37022249

ABSTRACT

Thromboembolism in blood vessels can lead to stroke or heart attack and even sudden death unless brought under control. Sonothrombolysis enhanced by ultrasound contrast agents has shown promising outcome on effective treatment of thromboembolism. Intravascular sonothrombolysis was also reported recently with a potential for effective and safe treatment of deep thrombosis. Despite the promising treatment results, the treatment efficiency for clinical application may not be optimized due to the lack of imaging guidance and clot characterization during the thrombolysis procedure. In this paper, a miniaturized transducer was designed to have an 8-layer PZT-5A stacked with an aperture size of 1.4 × 1.4 mm2 and assembled in a customized two-lumen 10-Fr catheter for intravascular sonothrombolysis. The treatment process was monitored with internal-illumination photoacoustic tomography (II-PAT), a hybrid imaging modality that combines the rich contrast of optical absorption and the deep penetration of ultrasound detection. With intravascular light delivery using a thin optical fiber integrated with the intravascular catheter, II-PAT overcomes the penetration depth limited by strong optical attenuation of tissue. In-vitro PAT-guided sonothrombolysis experiments were carried out with synthetic blood clots embedded in tissue phantom. Clot position, shape, stiffness, and oxygenation level can be estimated by II-PAT at clinically relevant depth of ten centimeters. Our findings have demonstrated the feasibility of the proposed PAT-guided intravascular sonothrombolysis with real-time feedback during the treatment process.


Subject(s)
Photoacoustic Techniques , Thrombosis , Thrombosis/diagnostic imaging , Transducers , Photoacoustic Techniques/instrumentation , Photoacoustic Techniques/methods , Light , Humans
10.
Opt Express ; 30(2): 2933-2948, 2022 Jan 17.
Article in English | MEDLINE | ID: mdl-35209424

ABSTRACT

Maintaining a high spatial resolution in photoacoustic microscopy (PAM) of deep tissues is difficult due to large aberration in an objective lens with high numerical aperture and photoacoustic wave attenuation. To address the issue, we integrate transmission-type adaptive optics (AO) in high-resolution PAM with a low-frequency ultrasound transducer (UT), which increases the photoacoustic wave detection efficiency. AO improves lateral resolution and depth discrimination in PAM, even for low-frequency ultrasound waves by focusing a beam spot in deep tissues. Using the proposed PAM, we increased the lateral resolution and depth discrimination for blood vessels in mouse ears.


Subject(s)
Blood Vessels/diagnostic imaging , Ear/blood supply , Microscopy, Acoustic/instrumentation , Optics and Photonics , Photoacoustic Techniques/instrumentation , Transducers , Animals , Equipment Design , Mice
11.
Curr Med Sci ; 41(6): 1151-1157, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34907474

ABSTRACT

OBJECTIVE: This paper proposes a new photoacoustic computed tomography (PACT) imaging system employing dual ultrasonic transducers with different frequencies. When imaging complex biological tissues, photoacoustic (PA) signals with multiple frequencies are produced simultaneously; however, due to the limited bandwidth of a single-frequency transducer, the received PA signals with specific frequencies may be missing, leading to a low imaging quality. METHODS: In contrast to our previous work, the proposed system has a compact volume as well as specific selection of the detection center frequency of the transducer, which can provide a comprehensive range for the detection of PA signals. In this study, a series of numerical simulation and phantom experiments were performed to validate the efficacy of the developed PACT system. RESULTS: The images generated by our system combined the advantages of both high resolution and ideal brightness/contrast. CONCLUSION: The interchangeability of transducers with different frequencies provides potential for clinical deployment under the circumstance where a single frequency transducer cannot perform well.


Subject(s)
Image Enhancement/instrumentation , Photoacoustic Techniques/instrumentation , Tomography/instrumentation , Transducers , Equipment Design , Humans , Phantoms, Imaging
12.
Appl Opt ; 60(31): 9651-9658, 2021 Nov 01.
Article in English | MEDLINE | ID: mdl-34807146

ABSTRACT

A supercontinuum (SC) light source enables multispectral photoacoustic imaging at excitation wavelengths in the visible-to-near-infrared range. However, for such a broad optical wavelength range, chromatic aberration is non-negligible. We developed a multispectral optical-resolution photoacoustic microscopy (MS-OR-PAM) setup with a nanosecond pulsed SC light source and a reflective objective lens to avoid chromatic aberration. Chromatic aberrations generated by reflective and conventional objective lenses were compared, and the images acquired using the reflective objective were not affected by chromatic aberration. Hence, MS-OR-PAM with the reflective objective was used to distinguish red blood cells from melanoma cells via spectral subtraction processing.


Subject(s)
Erythrocytes/cytology , Image Processing, Computer-Assisted/methods , Light , Melanoma, Experimental/diagnostic imaging , Photoacoustic Techniques/instrumentation , Animals , Equipment Design , Mice , Optical Devices , Spectrum Analysis
13.
Opt Express ; 29(15): 24338-24348, 2021 Jul 19.
Article in English | MEDLINE | ID: mdl-34614681

ABSTRACT

An improved method of remote optical absorption spectroscopy and hyperspectral optical absorption imaging is described which takes advantage of the photoacoustic remote sensing detection architecture. A wide collection of photoacoustic excitation wavelengths ranging from 210 nm to 1550 nm was provided by a nanosecond tunable source allowing access to various salient endogenous chromophores such as DNA, hemeproteins, and lipids. Sensitivity of the device was demonstrated by characterizing the infrared absorption spectrum of water. Meanwhile, the efficacy of the technique was explored by recovering cell nuclei and oxygen saturation from a live chicken embryo model and by recovering adipocytes from freshly resected murine adipose tissue. This represents a continued investigation into the characteristics of the hyperspectral photoacoustic remote sensing technique which may represent an effective means of non-destructive endogenous contrast characterization and visualization.


Subject(s)
Chorioallantoic Membrane/chemistry , DNA/analysis , Hemoglobins/analysis , Lipids/analysis , Microscopy/methods , Photoacoustic Techniques/instrumentation , Remote Sensing Technology/instrumentation , Animals , Chick Embryo , Light , Oxygen Saturation , Spectrum Analysis
14.
Comput Math Methods Med ; 2021: 6622255, 2021.
Article in English | MEDLINE | ID: mdl-34707684

ABSTRACT

Photoacoustic imaging (PAI) is a new nonionizing, noninvasive biomedical imaging technology that has been employed to reconstruct the light absorption characteristics of biological tissues. The latest developments in compressed sensing (CS) technology have shown that it is possible to accurately reconstruct PAI images from sparse data, which can greatly reduce scanning time. This study focuses on the comparative analysis of different CS-based total variation regularization reconstruction algorithms, aimed at finding a method suitable for PAI image reconstruction. The performance of four total variation regularization algorithms is evaluated through the reconstruction experiment of sparse numerical simulation signal and agar phantom signal data. The evaluation parameters include the signal-to-noise ratio and normalized mean absolute error of the PAI image and the CPU time. The comparative results demonstrate that the TVAL3 algorithm can well balance the quality and efficiency of the reconstruction. The results of this study can provide some useful guidance for the development of the PAI sparse reconstruction algorithm.


Subject(s)
Algorithms , Diagnostic Imaging/methods , Image Processing, Computer-Assisted/statistics & numerical data , Photoacoustic Techniques/statistics & numerical data , Computational Biology , Computer Simulation , Diagnostic Imaging/statistics & numerical data , Humans , Phantoms, Imaging , Photoacoustic Techniques/instrumentation , Signal-To-Noise Ratio
15.
Proc Natl Acad Sci U S A ; 118(36)2021 09 07.
Article in English | MEDLINE | ID: mdl-34480005

ABSTRACT

The development of high-performance photoacoustic (PA) probes that can monitor disease biomarkers in deep tissue has the potential to replace invasive medical procedures such as a biopsy. However, such probes must be optimized for in vivo performance and exhibit an exceptional safety profile. In this study, we have developed PACu-1, a PA probe designed for biopsy-free assessment (BFA) of hepatic Cu via photoacoustic imaging. PACu-1 features a Cu(I)-responsive trigger appended to an aza-BODIPY dye platform that has been optimized for ratiometric sensing. Owing to its excellent performance, we were able to detect basal levels of Cu in healthy wild-type mice as well as elevated Cu in a Wilson's disease model and in a liver metastasis model. To showcase the potential impact of PACu-1 for BFA, we conducted two blind studies in which we were able to successfully identify Wilson's disease animals from healthy control mice in each instance.


Subject(s)
Copper/metabolism , Hepatolenticular Degeneration/metabolism , Liver Neoplasms/secondary , Photoacoustic Techniques/instrumentation , Animals , Biopsy , Disease Models, Animal , Hepatolenticular Degeneration/pathology , Mice , Mice, Inbred BALB C , Tissue Distribution
16.
Cancer Res ; 81(18): 4849-4860, 2021 09 15.
Article in English | MEDLINE | ID: mdl-34185675

ABSTRACT

Thyroid cancer is one of the most common cancers, with a global increase in incidence rate for both genders. Ultrasound-guided fine-needle aspiration is the current gold standard to diagnose thyroid cancers, but the results are inaccurate, leading to repeated biopsies and unnecessary surgeries. To reduce the number of unnecessary biopsies, we explored the use of multiparametric photoacoustic (PA) analysis in combination with the American Thyroid Association (ATA) Guideline (ATAP). In this study, we performed in vivo multispectral PA imaging on thyroid nodules from 52 patients, comprising 23 papillary thyroid cancer (PTC) and 29 benign cases. From the multispectral PA data, we calculated hemoglobin oxygen saturation level in the nodule area, then classified the PTC and benign nodules with multiparametric analysis. Statistical analyses showed that this multiparametric analysis of multispectral PA responses could classify PTC nodules. Combining the photoacoustically indicated probability of PTC and the ATAP led to a new scoring method that achieved a sensitivity of 83% and a specificity of 93%. This study is the first multiparametric analysis of multispectral PA data of thyroid nodules with statistical significance. As a proof of concept, the results show that the proposed new ATAP scoring can help physicians examine thyroid nodules for fine-needle aspiration biopsy, thus reducing unnecessary biopsies. SIGNIFICANCE: This report highlights a novel photoacoustic scoring method for risk stratification of thyroid nodules, where malignancy of the nodules can be diagnosed with 83% sensitivity and 93% specificity.


Subject(s)
Photoacoustic Techniques , Thyroid Neoplasms/diagnosis , Thyroid Nodule/diagnosis , Biomarkers , Clinical Decision-Making , Diagnosis, Differential , Disease Management , Humans , Image Processing, Computer-Assisted , Oxygen Saturation , Photoacoustic Techniques/instrumentation , Photoacoustic Techniques/methods , ROC Curve , Sensitivity and Specificity , Thyroid Neoplasms/etiology , Ultrasonography/methods , Ultrasonography/standards , Workflow
17.
Appl Opt ; 60(15): C55-C59, 2021 May 20.
Article in English | MEDLINE | ID: mdl-34143106

ABSTRACT

Molecular gases are highly relevant in healthcare, production control, safety, and environmental monitoring. They often appear in small concentrations. The measurement of trace gases has increasingly become a key technique in those domains. Quartz-enhanced photoacoustic spectroscopy (QEPAS) is a suitable method that can provide the required low detection limits in such applications at comparatively low cost and small size. For mobile implementation, the size of an entire sensor unit matters. In this paper, we present a QEPAS sensor that fits into a standard butterfly package, its characterization, and its application on CH4 and CO2.


Subject(s)
Air Pollutants/analysis , Biosensing Techniques/instrumentation , Carbon Dioxide/analysis , Methane/analysis , Photoacoustic Techniques/instrumentation , Quartz/chemistry , Spectrum Analysis/methods , Environmental Monitoring/methods , Equipment Design
18.
Ann Biomed Eng ; 49(8): 1861-1873, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33909192

ABSTRACT

Functional photoacoustic imaging of the placenta could provide an innovative tool to diagnose preeclampsia, monitor fetal growth restriction, and determine the developmental impacts of gestational diabetes. However, transabdominal photoacoustic imaging is limited in imaging depth due to the tissue's scattering and absorption of light. The aim of this paper was to investigate the impact of geometry and wavelength on transabdominal light delivery. Our methods included the development of a multilayer model of the abdominal tissue and simulation of the light propagation using Monte Carlo methods. A bifurcated light source with varying incident angle of light, distance between light beams, and beam area was simulated to analyze the effect of light delivery geometry on the fluence distribution at depth. The impact of wavelength and the effects of variable thicknesses of adipose tissue and muscle were also studied. Our results showed that the beam area plays a major role in improving the delivery of light to deep tissue, in comparison to light incidence angle or distance between the bifurcated fibers. Longer wavelengths, with incident fluence at the maximum permissible exposure limit, also increases fluence within deeper tissue. We validated our simulations using a commercially available light delivery system and ex vivo human placental tissue. Additionally, we compared our optimized light delivery to a commercially available light delivery system, and conclude that our optimized geometry could improve imaging depth more than 1.6×, bringing the imaging depth to within the needed range for transabdominal imaging of the human placenta.


Subject(s)
Computer Simulation , Models, Biological , Photoacoustic Techniques/instrumentation , Placenta/diagnostic imaging , Female , Humans , Monte Carlo Method , Phantoms, Imaging , Pregnancy
19.
Appl Opt ; 60(10): 2907-2911, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-33798172

ABSTRACT

There is a great need for cost-efficient non-invasive medical diagnostic tools for analyzing humanly exhaled air. Compared to present day methods, photoacoustic spectroscopy (PAS) can provide a compact and portable (bedside), sensitive and inexpensive solution. We demonstrate a novel portable photoacoustic spectroscopic platform for isotopic measurements of methane (CH4). We identify and discriminate the 12CH4- and 13CH4 isotopologues and determine their mixing ratio. An Allan deviation analysis shows that the noise equivalent concentration for CH4 is 200 ppt (pmol/mol) at 100 s of integration time, corresponding to a normalized noise equivalent absorption coefficient of 5.1×10-9Wcm-1Hz-1/2, potentially making the PAS sensor a truly disruptive instrument for bedside monitoring using isotope tracers by providing real-time metabolism data to clinical personnel.


Subject(s)
Breath Tests/methods , Carbon Isotopes/chemistry , Methane/analysis , Photoacoustic Techniques/methods , Biosensing Techniques , Breath Tests/instrumentation , Equipment Design , Exhalation , Humans , Photoacoustic Techniques/instrumentation , Spectrophotometry, Infrared
20.
Methods Mol Biol ; 2265: 203-212, 2021.
Article in English | MEDLINE | ID: mdl-33704716

ABSTRACT

Early detection of cancer has been a goal of cancer research in general and melanoma research in particular (Birnbaum et al., Lancet Glob Health 6:e885-e893, 2018; Alendar et al., Bosnian J Basic Med Sci 9:77-80, 2009). Early detection of metastasis has been targeted as pivotal to increasing survival rates (Menezes et al., Adv Cancer Res 132:1-44, 2016). Melanoma, though curable in its early stages, has a dramatic decrease in survival rates once metastasis has occurred (Sharma et al., Biotechnol Adv 36:1063-1078, 2018). The transition to metastasis is not well understood and is an area of increasing interest. Metastasis is always premeditated by the shedding of circulating tumor cells (CTCs) from the primary tumor. The ability to isolate rare CTCs from the bloodstream has led to a host of new targets and therapies for cancer (Micalizzi et al., Genes Dev 31:1827-1840, 2017). Detection of CTCs also allows for disease progression to be tracked in real time while eliminating the need to wait for additional tumors to grow. Using a photoacoustic flowmeter, in which we induce ultrasonic responses from circulating melanoma cells (CMCs), we identify and quantify these cells in order to track disease progression. Additionally, these CMCs are captured and isolated allowing for future analysis such as RNA-Seq or microarray analysis.


Subject(s)
Flow Cytometry/methods , Melanoma/diagnosis , Neoplastic Cells, Circulating , Photoacoustic Techniques/instrumentation , Photoacoustic Techniques/methods , Rheology/instrumentation , Rheology/methods , Skin Neoplasms/diagnosis , Disease Progression , Early Detection of Cancer/methods , Flow Cytometry/instrumentation , Gene Library , Humans , Immunohistochemistry/methods , Melanoma/blood , Melanoma/genetics , Melanoma/pathology , Neoplasm Metastasis/diagnosis , Neoplasm Metastasis/pathology , Neoplastic Cells, Circulating/pathology , Real-Time Polymerase Chain Reaction , Skin Neoplasms/blood , Skin Neoplasms/genetics , Skin Neoplasms/pathology , Ultrasonography/methods
SELECTION OF CITATIONS
SEARCH DETAIL