Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 2.376
1.
J Coll Physicians Surg Pak ; 34(6): 717-722, 2024 Jun.
Article En | MEDLINE | ID: mdl-38840358

OBJECTIVE: To determine the clinical applicability of the modified concentric cannula technique (CCT), focusing on the duration of the arthrocentesis, the number of reposition of cannula, and the occurrence of complications. STUDY DESIGN: Descriptive study. Place and Duration of the Study: Department of Oral and Maxillofacial Surgery, Ankara Yildirim Beyazit University, Ankara, Turkiye, between September 2021 and May 2022. METHODOLOGY: Forty patients with Wilkes III temporomandibular joints (TMJ) internal derangement were identified and 13 patients who met the inclusion criteria were reviewed. The main outcomes regarding the clinical applicability of modified CCT included the duration of arthrocentesis, the number of reposition of cannula, and the occurrence of complications. RESULTS: The values of maximum mouth opening (MMO) without pain and MMO without assistance measured in the immediate postoperative period and at the 4th and 8th postoperative weeks were found to be significantly higher than the pre-arthrocentesis values. The values of MMO with assistance measured in the immediate postoperative period and at the 8th postoperative week were also significantly higher than the baseline values. Compared with preoperative values, notable decreases in pain scores were observed at the 4th (p = 0.003) and 8th (p = 0.002) postoperative weeks. The assessment of the jaw dysfunction also revealed significantly lower scores at the 4th (p = 0.024) and 8th (p <0.001) postoperative weeks. CONCLUSION: Modified CCT of arthrocentesis substantially decreased pain and improved mandibular functions in patients with internal derangement of TMJ. Additionally, this technique could be performed with a reduced number of cannula relocations and required a shorter operative time even with the use of a higher irrigation volume during the lavage procedure. KEY WORDS: Arthrocentesis, Temporomandibular joint disorder, Temporomandibular joint.


Arthrocentesis , Temporomandibular Joint Disorders , Humans , Arthrocentesis/methods , Male , Female , Temporomandibular Joint Disorders/surgery , Adult , Middle Aged , Punctures/methods , Needles , Treatment Outcome , Young Adult , Temporomandibular Joint/surgery , Range of Motion, Articular , Cannula
2.
Zhonghua Nei Ke Za Zhi ; 63(6): 550-559, 2024 Jun 01.
Article Zh | MEDLINE | ID: mdl-38825924

Thyroid nodule and cervical lymph node biopsy is the main clinical method for evaluating the condition and determining the follow-up treatment plan. The literature on thyroid nodule puncture predominantly focuses on thyroid fine needle puncture, and there are limited systematic articles on coarse needle aspiration for thyroid-related diseases and needle biopsy of thyroid-related cervical lymph node diseases. However, this shortage of articles does not reflect the diagnostic value of coarse needle aspiration in thyroid biopsy and cervical lymph node-related diseases. Currently, different departments of many hospitals in China are conducting or planning to perform needle biopsy of thyroid and cervical lymph node-related diseases to improve the standardization and safety of related operations. Standardization is needed for the indications, contraindications, perioperative period, postoperative complications management, puncture specimen processing, and related genetic analysis of thyroid and cervical lymph node puncture. For this purpose, Interventional Ultrasound Committee of Chinese College of Interventionalists organized a panel of domestic experts in the field of thyroid diseases to discuss and formulate a consensus. Based on the latest research progress, combined with the clinical realities in China, this Expert Consensus on Ultrasound Guided Thyroid and Neck Lymph Node Puncture (2023 edition) is released.


Lymph Nodes , Neck , Thyroid Gland , Humans , Lymph Nodes/diagnostic imaging , Lymph Nodes/pathology , Thyroid Gland/diagnostic imaging , Thyroid Gland/pathology , China , Biopsy, Fine-Needle/methods , Thyroid Nodule/diagnostic imaging , Thyroid Nodule/pathology , Consensus , Ultrasonography, Interventional/methods , Punctures/methods
3.
J Vis Exp ; (207)2024 May 24.
Article En | MEDLINE | ID: mdl-38856226

Hemostasis, the process of normal physiological control of vascular damage, is fundamental to human life. We all suffer minor cuts and puncture wounds from time to time. In hemostasis, self-limiting platelet aggregation leads to the formation of a structured thrombus in which bleeding cessation comes from capping the hole from the outside. Detailed characterization of this structure could lead to distinctions between hemostasis and thrombosis, a case of excessive platelet aggregation leading to occlusive clotting. An imaging-based approach to puncture wound thrombus structure is presented here that draws upon the ability of thin-section electron microscopy to visualize the interior of hemostatic thrombi. The most basic step in any imaging-based experimental protocol is good sample preparation. The protocol provides detailed procedures for preparing puncture wounds and platelet-rich thrombi in mice for subsequent electron microscopy. A detailed procedure is given for in situ fixation of the forming puncture wound thrombus and its subsequent processing for staining and embedding for electron microscopy. Electron microscopy is presented as the end imaging technique because of its ability, when combined with sequential sectioning, to visualize the details of the thrombus interior at high resolution. As an imaging method, electron microscopy gives unbiased sampling and an experimental output that scales from nanometer to millimeters in 2 or 3 dimensions. Appropriate freeware electron microscopy software is cited that will support wide-area electron microscopy in which hundreds of frames can be blended to give nanometer-scale imaging of entire puncture wound thrombi cross-sections. Hence, any subregion of the image file can be placed easily into the context of the full cross-section.


Microscopy, Electron , Thrombosis , Animals , Mice , Microscopy, Electron/methods , Thrombosis/pathology , Hemostasis , Punctures/methods
4.
BMJ Case Rep ; 17(5)2024 May 13.
Article En | MEDLINE | ID: mdl-38740444

With the advancements in the medical field, many innovations in medical devices have happened. Using a surgical stapler to close the laryngectomy defect without opening the pharynx is particularly advantageous in a total laryngectomy (TL). However, performing the tracheoesophageal puncture (TEP) during stapler closure of the larynx has not been widely advocated, due to the fear of complications related to the procedure.We treated two male patients with advanced glottic malignancy who underwent a TL. To restore their ability to speak, we performed a primary TEP and immediate voice prosthesis placement. After the TEP, we closed the larynx using a stapler. The surgical technique used in this procedure has been thoroughly explained.The use of a surgical stapler for pharyngeal closure during a TL has several advantages, particularly with regard to the duration of surgery. The current techniques appear to be promising in reducing TEP-related complications during stapler-assisted laryngeal closure.


Laryngeal Neoplasms , Laryngectomy , Punctures , Trachea , Humans , Male , Laryngectomy/methods , Laryngectomy/adverse effects , Laryngeal Neoplasms/surgery , Punctures/methods , Trachea/surgery , Esophagus/surgery , Surgical Staplers , Aged , Middle Aged , Larynx/surgery , Surgical Stapling/methods , Larynx, Artificial
5.
Urolithiasis ; 52(1): 75, 2024 May 16.
Article En | MEDLINE | ID: mdl-38753168

This study was designed to evaluate the non-inferiority of ultrasound puncture followed by endoscopically guided tract dilatation compared to the standard fluoroscopy-guided PCNL. Forty patients with non-opaque kidney stones eligible for PCNL were randomly divided into two groups. The standard fluoroscopy-guided PCNL using the Amplatz dilator was performed in the XRAY group. In the SONO group, the Kidney was punctured under an ultrasound guide followed by tract dilatation using a combination of the Amplatz dilator based on the tract length and an endoscopically guided tract dilatation using a bi-prong forceps in cases of short-advancement. The primary outcome was successful access. In 90% of cases in the XRAY and 95% in the SONO group access dilatation process was performed uneventfully at the first attempt (p = 0.5). In 45% of cases in the SONO group, bi-prong forceps were used as salvage for short-advancement. In one case in the X-ray group over-advancement occurred. One month after surgery, the stone-free rate on the CT-scan was 75% for the X-ray group and 85% for the SONO group (p = 0.4). There were no significant differences in operation time, hospitalization duration, transfusion, or complication rates between the two groups. We conclude that ultrasound-guided renal puncture, followed by endoscopically guided tract dilatation can achieve a high success rate similar to X-ray-guided PCNL while avoiding the harmful effects of radiation exposure and the risk of over-advancement.


Dilatation , Kidney Calculi , Nephrolithotomy, Percutaneous , Punctures , Ultrasonography, Interventional , Humans , Fluoroscopy/methods , Kidney Calculi/surgery , Kidney Calculi/diagnostic imaging , Nephrolithotomy, Percutaneous/methods , Nephrolithotomy, Percutaneous/adverse effects , Nephrolithotomy, Percutaneous/instrumentation , Male , Female , Middle Aged , Punctures/methods , Dilatation/methods , Dilatation/instrumentation , Adult , Kidney/surgery , Kidney/diagnostic imaging , Treatment Outcome , Aged
6.
Clin Neurol Neurosurg ; 242: 108331, 2024 Jul.
Article En | MEDLINE | ID: mdl-38795688

OBJECTIVE: Effective thrombectomies in the posterior circulation remain controversial. Previous reports have demonstrated the superiority of contact aspiration in anterior circulation. Aspiration catheters and stent retrievers are often used alone on a global scale, while combined techniques are commonly used in Japan. This study evaluated the effect of first-line contact aspiration with other strategies for the treatment of basilar artery occlusion. METHODS: The primary outcome was the frequency of the first-pass effect, and the secondary outcome was the time from puncture to the first-pass effect. A multicenter observational registry including 16 Japanese stroke centers was used. Between December 2013 and February 2021, enrolled patients underwent endovascular thrombectomy for basilar artery occlusion. The efficacy of contact aspiration compared to other methods (including stent retrievers and combined techniques) was evaluated. RESULTS: Eighty-four patients were included, all of whom had achieved effective recanalization. Twenty-six patients were treated with contact aspiration, 13 with combined technique, and 45 with stent retrievers. The two groups: contact aspiration and non-contact aspiration, had different backgrounds. Both had similar frequencies of effective recanalization and first-pass effects. The contact aspiration group experienced better functional outcomes without statistical significance, while this strategy was significantly associated with a shorter puncture-to-recanalization time (38 vs. 55 minutes, P=0.036). In particular, in the 55 patients with the first-pass effect, multivariate Cox proportional hazard analysis showed that contact aspiration was significantly associated with a shorter time from puncture to first-pass effect, independent of age and etiology of large-artery atherosclerosis (hazard ratio 2.02, 95% confidence intervals 1.10-3.69, P=0.023). CONCLUSION: This study suggested that contact aspiration for basilar artery occlusion may shorten the puncture-to-first-pass effect, compared to stent retrievers and combined techniques.


Endovascular Procedures , Thrombectomy , Humans , Male , Female , Aged , Middle Aged , Thrombectomy/methods , Endovascular Procedures/methods , Vertebrobasilar Insufficiency/surgery , Treatment Outcome , Punctures/methods , Aged, 80 and over , Registries , Time-to-Treatment , Basilar Artery/surgery , Stents , Suction/methods
7.
Vestn Otorinolaringol ; 89(2): 15-20, 2024.
Article Ru | MEDLINE | ID: mdl-38805458

OBJECTIVE: Optimization of the method of puncture treatment of acute bacterial maxillary sinusitis (ABMS) through the development of original devices for drainage of the maxillary sinus (MS). MATERIAL AND METHODS: Registration and comparative analysis of the results of puncture methods of treatment of 120 patients with ABMS using developed new original devices for drainage of MS with one channels and with two channels in comparison with the Kulikovsky's needle (KN) was carried out. Based on the results of the analysis, the effectiveness of the original devices was assessed. During the clinical study, patients were divided into two groups: in group I, patients underwent of the MS puncture using KN, in group II, using original devices. Groups I and II, depending on the absence or presence of a block of the natural anastomosis MS, was divided into subgroups A and B, respectively. After puncture of the MS, the pain syndrome was assessed by patients using Visual Analogue Scale (VAS) and by doctors - using Touch Visual Pain (TVP) scale. RESULTS: Our study showed that when puncturing the upper jaw with an original needle with one channels and with two channels, compared with the use of KN, there is a decrease in pain (the average VAS score was 1.5±0.3 and 1.7±0.3 points, respectively; the average TVP scale score was 0.9±0.2 and 1.8±0.3 points, respectively, the difference is significant, p≤0.05). Patients of subgroup IB were manipulated with two KN, patients of subgroup IIB manipulated using the original device with two channels without an additional needle (the average VAS score was 3.0±0.4 and 1.3±0.3 points, respectively; the average TVP scale score was 2.7±0.4 and 1.0±0.2 points, respectively, the difference is significant, p≤0.05). The doctors also assessed the devices used for puncture of the upper jaw. As a result of the study, the high efficiency and safety of using new original devices was established.


Maxillary Sinusitis , Punctures , Humans , Maxillary Sinusitis/microbiology , Maxillary Sinusitis/therapy , Maxillary Sinusitis/diagnosis , Female , Male , Adult , Punctures/methods , Punctures/instrumentation , Middle Aged , Treatment Outcome , Drainage/methods , Drainage/instrumentation , Pain Measurement/methods , Maxillary Sinus/microbiology , Maxillary Sinus/surgery , Acute Disease , Bacterial Infections/therapy , Bacterial Infections/diagnosis
8.
Medicine (Baltimore) ; 103(14): e37723, 2024 Apr 05.
Article En | MEDLINE | ID: mdl-38579029

INTRODUCTION: Transseptal punctures (TSPs) are widely used in left atrium and left ventricle surgery. Accidental puncture of the puncture needle into the aorta is a rare complication that is rarely reported but has serious consequences. The appropriate management of this complication remains unclear. PATIENT CONCERNS: This report describes a case of a male with the chief complaint: paroxysmal palpitation for 1 year, aggravated for 1 month. DIAGNOSIS: The electrophysiological diagnosis was atrioventricular reentrant tachycardia caused by left-side bypass. INTERVENTIONS: Radiofrequency ablation of the heart was a necessary treatment and a TSP operation was needed, in which a puncture was mistakenly believed to have entered the aorta, a series of measures were taken urgently. Although the surgical procedure in this case was a false alarm, we still initiated a series of emergency plans. Emergency measures to address the complications were effectively implemented, and the emergency measures were promptly terminated after it was clear that complications had been misjudged. OUTCOMES: At last, it was confirmed that the angiogram was a pulmonary artery image, not an aorta image. Then the atrial septal puncture operation was successfully completed, and under the guidance of the Carto system, the ablation was successfully completed. Postoperative fluoroscopy showed no complications, such as pericardial effusion. After 2 years of follow-up, there was no reoccurrence of tachycardia, and there were no complications. It is crucial that emergency procedures are terminated in a timely manner after a clear miscarriage of performance. Although accidental puncture into the aorta is urgent and serious, performing a blockage or even thoracotomy in an emergency if complications are not clearly confirmed can cause further damage to the patient and would be a definitively wrong strategy. CONCLUSION: Strict and standardized TSP operations can avoid complications. Correct judgment of the authenticity of complications is crucial, and remedial measures that may cause further damage should not be blindly adopted. The retention of the aortic guide wire can provide convenient access for further differential diagnosis and remedial treatment.


Atrial Fibrillation , Catheter Ablation , Heart Septal Defects, Atrial , Radiofrequency Ablation , Humans , Male , Aorta/surgery , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Heart Septal Defects, Atrial/surgery , Punctures/adverse effects , Punctures/methods , Treatment Outcome
9.
Curr Oncol ; 31(4): 2047-2056, 2024 04 04.
Article En | MEDLINE | ID: mdl-38668054

BACKGROUND: Castleman disease (CD) is an uncommon benign lymphoproliferative disease characterized by hypervascular lymphoid hyperplasia. We present a unique case of unicentric CD of the parotid gland treated by preoperative direct puncture embolization. CASE PRESENTATION: A 27-year-old female patient was admitted for a right neck mass. Ultrasound examination and MRI scan documented a hypervascular mass within the right parotid gland. Preoperative embolization was performed by direct puncture technique: a needle was inserted into the core of the mass under both ultrasound and fluoroscopic guidance and SQUID 12 was injected into the mass under fluoroscopic control, achieving a total devascularization. CONCLUSION: Preoperative direct puncture embolization was safe and effective and provides excellent hemostatic control during the surgical operation, limiting the amount of intraoperative bleeding.


Castleman Disease , Embolization, Therapeutic , Humans , Female , Adult , Castleman Disease/therapy , Castleman Disease/surgery , Embolization, Therapeutic/methods , Parotid Gland , Preoperative Care/methods , Punctures/methods , Magnetic Resonance Imaging
10.
Clin Neurol Neurosurg ; 241: 108292, 2024 06.
Article En | MEDLINE | ID: mdl-38657327

OBJECTIVE: Accurate localization and real-time guidance technologies for cerebral hematomas are essential for minimally invasive procedures, including minimally invasive hematoma puncture and drainage, as well as neuroendoscopic-assisted hematoma removal. This study aims to evaluate the precision and safety of a self-developed laser-guided device in localizing and guiding hematoma punctures in minimally invasive surgery for intracerebral hemorrhage (ICH). METHODS: We present the components of the device and its operational procedures. Subsequently, surgeons with different titles conduct hematoma puncture experiments using the device on skull models, comparing it to freehand puncture methods and recording the offset distance from the puncture needle tip to the hematoma center. Additionally, we report the application of this device in 10 patients with ICH, assessing its accuracy and safety in comparison with a neuro-navigation system. RESULTS: In simulated puncture experiments, the accuracy of the laser-guided group surpasses that of the freehand puncture group, with a significant statistical difference observed between the two groups (P < 0.05). In the laser-guided group, there is no statistically significant difference in puncture accuracy among the surgeons (P > 0.05). In clinical experiments, no relevant surgical complications were observed. The offset distance for the laser-guided group was 0.61 ± 0.18 cm, while the neuro-navigation group was 0.48 ± 0.13 cm. There was no statistically significant difference between the two groups in terms of offset distance (P > 0.05). However, there was a significant difference in surgical duration (P < 0.05), with the former being 35.0 ± 10.5 minutes and the latter being 63.8 ± 10.5 minutes. CONCLUSION: The current study describes satisfactory results from both simulated experiments and clinical applications, achieved through the use of a novel laser-guided hematoma puncture device. Furthermore, owing to its portability, affordability, and simplicity, it holds significant importance in advancing surgical interventions for ICH, especially in underdeveloped regions.


Cerebral Hemorrhage , Punctures , Humans , Cerebral Hemorrhage/surgery , Cerebral Hemorrhage/diagnostic imaging , Punctures/methods , Male , Female , Aged , Middle Aged , Hematoma/surgery , Hematoma/diagnostic imaging , Lasers , Minimally Invasive Surgical Procedures/methods , Neuronavigation/methods , Neurosurgical Procedures/methods
11.
J Xray Sci Technol ; 32(3): 825-837, 2024.
Article En | MEDLINE | ID: mdl-38517837

OBJECTIVE: In this study, the three-dimensional relationship between the optimal puncture needle path and the lumbar spinous process was discussed using digital technology. Additionally, the positioning guide plate was designed and 3D printed in order to simulate the surgical puncture of specimens. This plate served as an important reference for the preoperative simulation and clinical application of percutaneous laser decompression (PLD). METHOD: The CT data were imported into the Mimics program, the 3D model was rebuilt, the ideal puncture line N and the associated central axis M were developed, and the required data were measured. All of these steps were completed. A total of five adult specimens were chosen for CT scanning; the data were imported into the Mimics program; positioning guide plates were generated and 3D printed; a simulated surgical puncture of the specimens was carried out; an X-ray inspection was carried out; and an analysis of the puncture accuracy was carried out. RESULTS: (1) The angle between line N and line M was 42°~55°, and the angles between the line M and 3D plane were 1°~2°, 5°~12°, and 78°~84°, respectively; (2) As the level of the lumbar intervertebral disc decreases, the distance from point to line and point to surface changes regularly; (3) The positioning guide was designed with the end of the lumbar spinous process and the posterior superior iliac spine on both sides as supporting points. (4) Five specimens were punctured 40 times by using the guide to simulate surgical puncture, and the success rate was 97.5%. CONCLUSION: By analyzing the three-dimensional relationship between the optimal puncture needle path and the lumbar spinous process, the guide plate was designed to simulate surgical puncture, and the individualized safety positioning of percutaneous puncture was obtained.


Imaging, Three-Dimensional , Lumbar Vertebrae , Needles , Punctures , Tomography, X-Ray Computed , Humans , Imaging, Three-Dimensional/methods , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/surgery , Punctures/methods , Tomography, X-Ray Computed/methods , Decompression, Surgical/methods , Decompression, Surgical/instrumentation , Printing, Three-Dimensional , Adult , Spinal Puncture/methods , Spinal Puncture/instrumentation , Lasers
12.
J Pediatr Urol ; 20(3): 541-543, 2024 Jun.
Article En | MEDLINE | ID: mdl-38519285

INTRODUCTION: Associating minipercutaneous nephrolithotomy and retrograde flexible ureteroscopy (fURS) is called Mini Endoscopic Combined Intra-Renal Surgery (miniECIRS). It's a safe and efficient technique, also in children. MATERIAL AND METHODS: The video describes miniECIRS in a 12 month-old boy with an infectious pelvic left stone (16 mm) and multiple caliceal stones. The UAS used was a 10FR and the percutaneous access was a 14Fr with Clear-Petra® sheath. RESULTS: The operative time was 180 min and blood losses were virtually absent. There were no intra- or post-operative complications and the patient was discharged at the 5th day. After 1 month, double J was removed having a stone free status. CONCLUSIONS: MiniECIRS with endoview puncture is a safe and efficient technique when performed by experienced hands. Therefore, it is an alternative to consider for the treatment of complex lithiasis in the pediatric population.


Kidney Calculi , Nephrolithotomy, Percutaneous , Punctures , Ureteroscopy , Humans , Male , Ureteroscopy/methods , Kidney Calculi/surgery , Nephrolithotomy, Percutaneous/methods , Punctures/methods , Infant
13.
J Emerg Nurs ; 50(3): 373-380, 2024 May.
Article En | MEDLINE | ID: mdl-38530698

INTRODUCTION: Radial artery puncture has been performed by palpation as a standard method in many emergency departments and intensive care units. Nurses play an important role in the care of patients in various settings. Ultrasonography can be performed and interpreted not only by physicians but also by nurses. This study aimed to evaluate whether emergency nurses would be more successful in radial artery puncture procedure by using ultrasonography instead of palpation. METHODS: This single-center, prospective, randomized controlled study was conducted in the emergency department. The patients included in the study were randomized into 2 groups as ultrasonography and palpation groups. Data were recorded on the number of interventions, the duration of the procedure in seconds, total time in seconds, whether the puncture was successfully placed, whether there were complications, the types of complications (hematoma, bleeding, and infection), or whether it was necessary to switch to an alternative technique. RESULTS: A total of 72 patients, 36 patients in the ultrasonography group and 36 patients in the palpation group, participated in the study. The success rate at the first attempt was statistically significantly higher in the ultrasonography group. Although hematoma formation among the complications occurred in the entire palpation group, it was observed in 72.2% of the ultrasonography group. Puncture time and total time were statistically significantly lower in the ultrasonography group. DISCUSSION: Our study shows that emergency nurses can use bedside ultrasonography for radial artery puncture successfully.


Emergency Nursing , Emergency Service, Hospital , Radial Artery , Ultrasonography, Interventional , Humans , Radial Artery/diagnostic imaging , Female , Male , Prospective Studies , Emergency Nursing/methods , Middle Aged , Ultrasonography, Interventional/methods , Adult , Palpation/nursing , Palpation/methods , Aged , Punctures/methods , Catheterization, Peripheral/methods , Catheterization, Peripheral/nursing
14.
World Neurosurg ; 186: e213-e226, 2024 Jun.
Article En | MEDLINE | ID: mdl-38537786

BACKGROUND: The efficacy of surgical intervention in ameliorating long-term prognosis for moderate volume of cerebral hemorrhage in the thalamus-internal capsule region remains unsubstantiated by clinical investigations. Consequently, the acquisition of credible evidence is imperative to authenticate the effectiveness of these methodologies. METHODS: One hundred and three eligible patients with moderate-volume thalamus-internal capsule region cerebral hemorrhage. Twenty-seven pairs of successful matches after using the 1:1 propensity score matching method, totaling 54 patients, were analyzed. The short- and long-term treatment outcomes of patients in the stereotactic surgery and conservative treatment groups were compared. The prognosis of the 2 groups of patients was analyzed by logistic regression analysis and model comparison. RESULTS: The primary outcome of this study was to assess the assessment of daily living scores after 6 months of treatment. Based on the analysis of this study, the assessment of daily living of the surgical group were significantly higher than those of the conservative treatment group after 6 months of treatment (P < 0.001), and the difference was statistically significant. The amount of residual hematoma was significantly lower in the stereotactic surgery group than in the conservative treatment group at 3 days, 7 days, and 2 weeks after the onset of the disease (P < 0.001), and the complication rate was lower than the conservative treatment group (P < 0.05). Univariate logistic regression showed that the risk of severe neurological dysfunction for patients in the surgery group was (odds ratio -0.27, 95% confidence interval: 0.08-0.86, P < 0.05). In multivariate logistic regression analysis, the odds ratio was 0.29 (95% confidence interval: 0.09-0.96, P < 0.05) after adjusting for all covariates. CONCLUSIONS: For moderate-volume thalamus-internal capsule region cerebral hemorrhage, stereotactic paracentesis has the advantage of a shorter hospital stay and a lower complication rate than conservative treatment. Moreover, it yields superior outcomes in terms of daily living assessment scores after six months of treatment and enhanced neurological recovery.


Cerebral Hemorrhage , Internal Capsule , Stereotaxic Techniques , Thalamus , Humans , Female , Male , Middle Aged , Aged , Cerebral Hemorrhage/surgery , Thalamus/surgery , Thalamus/diagnostic imaging , Treatment Outcome , Internal Capsule/surgery , Activities of Daily Living , Adult , Punctures/methods
16.
Head Neck ; 46(4): 973-978, 2024 Apr.
Article En | MEDLINE | ID: mdl-38278774

Tracheoesophageal puncture (TEP) performed during total laryngectomy in the primary treatment of laryngeal cancer is the standard method for voice restoration. Following adjuvant radiotherapy, the TEP site can experience complications resulting in a tracheoesophageal fistula (TEF) with chronic leakage making oral alimentation unsafe due to aspiration. Here, we describe a technique using chimeric ulnar artery perforator forearm free flaps (UAPFF) in the reconstruction of these complex deformities. Four patients underwent chimeric UAPFF reconstruction of TEP site TEFs following primary TL with TEP and adjuvant radiotherapy. No flap failures or surgical complications occurred. Average time from end of radiotherapy to persistent TEF was 66 months (range 4-190 months). All patients had resolution in their TEF with average time to total oral diet achievement of 22 days (14-42 days). Chimeric UAPFF reconstruction is a safe and effective method to reconstruct recalcitrant TEP site TEFs.


Laryngeal Neoplasms , Larynx, Artificial , Tracheoesophageal Fistula , Humans , Tracheoesophageal Fistula/etiology , Tracheoesophageal Fistula/surgery , Forearm/surgery , Treatment Outcome , Retrospective Studies , Laryngectomy/adverse effects , Laryngectomy/methods , Laryngeal Neoplasms/radiotherapy , Laryngeal Neoplasms/surgery , Punctures/methods , Trachea/surgery
17.
Pacing Clin Electrophysiol ; 47(2): 330-335, 2024 02.
Article En | MEDLINE | ID: mdl-38240379

OBJECTIVE: This study aims to investigate the anatomical variations in femoral vasculature and evaluate the clinical value of ultrasound-guided femoral vein puncture in catheter ablation procedures. METHODS: In this retrospective analysis conducted from January 2023 to March 2023, we examined data from patients who underwent catheter ablation with ultrasound-guided femoral venipuncture. We evaluated the anatomy of the femoral vasculature at both high and low inguinal levels. Based on the relationship between the femoral vein and artery, we classified the anatomy into four types: Type I (vein parallel to artery without overlap), Type II (vein medial to artery with lumen overlap ≤50%), Type III (vein posterior to artery with lumen overlap > 50%), and Type IV (vein lateral to artery). Additionally, we assessed procedure-related vascular complications that required interventions or prolonged hospital stays. RESULTS: A total of 254 patients were included in this study. At the upper inguinal level, most cases (92.5%) exhibited Type II, followed by Type I (6.5%), while Type III (0.6%) and IV (0.4%) were less common. At the lower inguinal level, Type II accounted for 70.7%, there was a significantly higher proportion of Type III (23.4%) and Type IV (5.9%). The overall complication rate was 0.4%, no pseudoaneurysm or hematoma was observed in our study. CONCLUSION: Our study revealed significant anatomical variations in the relationship between the femoral vein and femoral artery. Ultrasound-guided femoral venipuncture significantly reduced vascular complication rate, making it a valuable tool for guiding puncture procedures.


Catheter Ablation , Phlebotomy , Humans , Femoral Vein/diagnostic imaging , Femoral Vein/surgery , Retrospective Studies , Arrhythmias, Cardiac , Punctures/methods , Femoral Artery/surgery , Femoral Artery/diagnostic imaging , Ultrasonography, Interventional
18.
Pacing Clin Electrophysiol ; 47(3): 448-454, 2024 03.
Article En | MEDLINE | ID: mdl-38291877

BACKGROUND: Application of electrocautery to a J-wire is used to perform transseptal puncture (TSP), but with limited evidence supporting safety and efficacy. We conducted a prospective randomized controlled trial to evaluate the safety and efficacy of this technique. METHODS: Two hundred consecutive patients were randomized in a 1:1 fashion to either the ICE-guided electrified J-wire TSP group or a conventional Brockenbrough (BRK) needle TSP group. The TSP was performed with a 0.032″ guidewire under 20 W, "coag" mode and was compared to TSP using the BRK needle. The primary safety endpoints were complications related to TSP. The primary efficacy endpoints included the TSP success rate, the total TSP time, and the total procedure time. RESULTS: All patients complete the procedure safely. The electrified J-wire TSP group had a significantly shorter TSP time than BRK needle TSP group. The total procedure time, number of TSP attempts required to achieve successful LA access, width of the intra-atrial shunt at the end of ablation were similar between the two groups. The incidence of new cerebral infarction detected by MRI were similar between the two groups (3/32 patients in the J-wire TSP group and 2/26 patients in conventional BRK TSP group, p = .82). And no difference in the incidence of residual intra-atrial shunt (4.3% vs. 6%, p = .654) during the 3-month's follow up. CONCLUSION: Using an electrified J-wire for TSP under the guidance of ICE appears to be as safe as and more efficient than conventional BRK needle TSP, which may be especially useful in the era of non-fluoroscopy AF ablation.


Atrial Fibrillation , Catheter Ablation , Humans , Heart Septum/diagnostic imaging , Heart Septum/surgery , Atrial Fibrillation/surgery , Prospective Studies , Punctures/methods , Catheter Ablation/methods , Echocardiography , Treatment Outcome
20.
Minim Invasive Ther Allied Technol ; 33(2): 102-108, 2024 Apr.
Article En | MEDLINE | ID: mdl-38047308

INTRODUCTION AND OBJECTIVES: Challenging percutaneous renal punctures to gain access to the kidney requiring guidance by cross-sectional imaging. To test the feasibility of robotic-assisted CT-guided punctures (RP) and compare them with manual laser-guided punctures (MP) with Uro Dyna-CT (Siemens Healthcare Solutions, Erlangen, Germany). MATERIAL AND METHODS: The silicon kidney phantom contained target lesions of three sizes. RP were performed using a robotic assistance system (guidoo, BEC GmbH, Pfullingen, Germany) with a robotic arm (LBR med R800, KUKA AG, Augsburg, Germany) and a navigation software with a cone-beam-CT Artis zeego (Siemens Healthcare GmbH, Erlangen, Germany). MP were performed using the syngo iGuide Uro-Dyna Artis Zee Ceiling CT (Siemens Healthcare Solutions). Three urologists with varying experience performed 20 punctures each. Success rate, puncture accuracy, puncture planning time (PPT), and needle placement time (NPT) were measured and compared with ANOVA and Chi-Square Test. RESULTS: One hundred eighteen punctures with a success rate of 100% for RP and 78% for MP were included. Puncture accuracy was significantly higher for RP. PPT (RP: 238 ± 90s, MP: 104 ± 21s) and NPT (RP: 128 ± 40s, MP: 81 ± 18s) were significantly longer for RP. The outcome variables did not differ significantly with regard to levels of investigators' experience. CONCLUSION: The accuracy of RP was superior to that of MP. This study paves the way for first in-human application of this robotic puncture system.


Robotic Surgical Procedures , Humans , Kidney/diagnostic imaging , Kidney/surgery , Punctures/methods , Cone-Beam Computed Tomography/methods , Phantoms, Imaging
...