Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 53.807
1.
J Nucl Med Technol ; 52(2): 152-157, 2024 Jun 05.
Article En | MEDLINE | ID: mdl-38839118

The National Cyclotron and PET Centre at Chulabhorn Hospital offers nuclear medicine diagnostic services using state-of-the-art digital PET/CT and PET/MRI machines as well as other related devices. Additionally, the center plays a vital role by having a cyclotron to produce radiopharmaceuticals, which are used both in-house and in other hospitals throughout the country. Despite the center's strict adherence to international standards regarding the use of radioactive substances in patients, there remains a potential risk of radiation exposure for operators, workers, and the public due to radioactive contamination and emissions from unsealed sources. Hence, it is imperative to assess and continuously monitor radiation levels in the work area to ensure the utmost level of safety for personnel. Methods: This study used optically stimulated luminescence dosimeters to measure radiation levels in 17 areas, consisting of 9 controlled and 8 supervised areas. Over a 3-mo period, the average monthly radiation dose was recorded for each location. Results: The PET/CT room registered the highest radiation dose within the controlled area, with a monthly average of 1.81 ± 0.29 mSv, equivalent to an annual dose of 21.72 mSv. This higher dose can be attributed to the significant number of patients served in this room. In supervised areas, the nursing counter located between the examination room and the patient waiting area exhibited the highest radiation exposure. The average monthly dose measured at this location was 0.085 ± 0.019 mSv, resulting in an annual dose of 1.015 mSv. Conclusion: The evaluation of radiation dose in controlled and supervised areas indicated that the overall radiation level remains within the prescribed limits. However, the slight excess that was observed at the nursing counter indicates the need for improvement to ensure compliance with the as-low-as-reasonably-achievable principle. Continuous monitoring of radiation levels should be conducted annually to maintain safety standards and minimize the risk that workers and the general public will be exposed to radioactivity.


Cyclotrons , Hospitals , Positron-Emission Tomography , Radiation Dosage , Thailand , Humans , Occupational Exposure/analysis , Occupational Exposure/prevention & control
2.
J Radiol Prot ; 44(2)2024 Jun 13.
Article En | MEDLINE | ID: mdl-38838649

Protection against ionizing radiations is important in laboratories with radioactive materials and high energy cyclotron beams. The Cyclotron and Radioisotope Center (CYRIC) located in Tohoku University in Miyagi prefecture, Japan and is a well-known nuclear science laboratory with cyclotron beams and substantial number of high activity radioactive materials. Considering this, it is important to perform complete radiation transport computations to ensure the safety of non-occupational and occupational workers. In the present work, we have developed a complete 3-dimensional model of the main cyclotron building and radiation labs using Monte Carlo method. We have found that the dispersed photons and neutrons inside and in the surrounding of the CYRIC building pose no significant risk to occupational and non-occupational workers. The present work and the developed models would be useful in the field of radiation protection.


Cyclotrons , Monte Carlo Method , Radiation Protection , Japan , Occupational Exposure/prevention & control , Occupational Exposure/analysis , Radiation Dosage , Computer Simulation , Humans , Universities
3.
Turk Kardiyol Dern Ars ; 52(4): 260-268, 2024 Jun.
Article En | MEDLINE | ID: mdl-38829631

OBJECTIVE: Ionizing radiation has long been used in the medical field. Catheter laboratories (cath labs) are recognized as areas where radiation exposure is notably high. This study aims to examine the levels of radiation exposure during various interventional procedures to raise awareness of this issue in Türkiye. METHODS: This study evaluated the procedure radiation doses (n = 2804) in the cath labs of four public hospitals with distinct characteristics. Radiation dose evaluation was conducted using Cumulative Air Kerma (CAK). The Kolmogorov-Smirnov test, Kruskal-Wallis H test, independent T-test, and Pearson correlation coefficient were utilized to analyze the data. A p-value of < 0.05 was considered statistically significant. Data were analyzed using IBM® Statistical Package for the Social Sciences (SPSS®) STATISTICS Version 26.0.0.0 (IBM Corporation, Armonk, New York, USA). RESULTS: The procedure radiation doses in the cath labs were documented. The findings are largely consistent with the literature. Notably, several outlier cases with extremely high radiation doses were identified [CAK (min-max) = 0.12 - 9.9 Gy]. Procedures such as chronic total occlusion (CTO) [Mean CAK: 3.8 (± 1.5) Gy] and percutaneous coronary interventions (PCI) [Mean CAK: 1.5 (± 1.4) Gy] were associated with high doses. Additionally, personnel attitudes toward radiation optimization in cath labs were found to be inadequate. CONCLUSION: The incidence of high radiation exposure during interventional procedures may be higher than expected in Türkiye. Further research is necessary to identify predictors and implement preventive measures to reduce these rates. For this purpose, establishing diagnostic radiation reference levels (DRLs) could help monitor national radiation levels.


Occupational Exposure , Radiation Dosage , Humans , Occupational Exposure/prevention & control , Radiation Exposure/prevention & control , Turkey , Cardiology , Attitude of Health Personnel , Female , Male
4.
Cancer Imaging ; 24(1): 73, 2024 Jun 12.
Article En | MEDLINE | ID: mdl-38867342

BACKGROUND: With the increasing prevalence of nonsmoking-related lung cancer in Asia, Asian countries have increasingly adopted low-dose computed tomography (LDCT) for lung cancer screening, particularly in private screening programs. This study examined how annual LDCT volume affects lung cancer stage distribution, overdiagnosis, and gender disparities using a hospital-based lung cancer database. METHODS: This study analyzed the annual utilized LDCT volume, clinical characteristics of lung cancer, stage shift distribution, and potential overdiagnosis. At the individual level, this study also investigated the relationship between stage 0 lung cancer (potential strict definition regarding overdiagnosis) and the clinical characteristics of lung cancer. RESULTS: This study reviewed the annual trend of 4971 confirmed lung cancer cases from 2008 to 2021 and conducted a link analysis with an LDCT imaging examination database over these years. As the volume of lung cancer screenings has increased over the years, the number and proportion of stage 0 lung cancers have increased proportionally. Our study revealed that the incidence of stage 0 lung cancer increased with increasing LDCT scan volume, particularly during the peak growth period from 2017 to 2020. Conversely, stage 4 lung cancer cases remained consistent across different time intervals. Furthermore, the increase in the lung cancer screening volume had a more pronounced effect on the increase in stage 0 lung cancer cases among females than it had among males. The estimated potential for overdiagnosis brought about by the screening process, compared to non-participating individuals, ranged from an odds ratio of 7.617 to one of 17.114. Both strict and lenient definitions of overdiagnosis (evaluating cases of stage 0 lung cancer and stages 0 to 1 lung cancer) were employed. CONCLUSIONS: These results provide population-level evidence of potential lung cancer overdiagnosis in the Taiwanese population due to the growing use of LDCT screening, particularly concerning the strict definition of stage 0 lung cancer. The impact was greater in the female population than in the male population, especially among females younger than 40 years. To improve lung cancer screening in Asian populations, creating risk-based prediction models for smokers and nonsmokers, along with gender-specific strategies, is vital for ensuring survival benefits and minimizing overdiagnosis.


Early Detection of Cancer , Lung Neoplasms , Overdiagnosis , Tomography, X-Ray Computed , Humans , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/epidemiology , Lung Neoplasms/pathology , Female , Male , Tomography, X-Ray Computed/methods , Tomography, X-Ray Computed/statistics & numerical data , Early Detection of Cancer/methods , Early Detection of Cancer/trends , Early Detection of Cancer/statistics & numerical data , Aged , Middle Aged , Sex Factors , Neoplasm Staging , Radiation Dosage , Retrospective Studies
5.
Phys Med ; 122: 103384, 2024 Jun.
Article En | MEDLINE | ID: mdl-38824827

The dosimetry evaluation for the selective internal radiation therapy is currently performed assuming a uniform activity distribution, which is in contrast with literature findings. A 2D microscopic model of the perfused liver was developed to evaluate the effect of two different 90Y microspheres distributions: i) homogeneous partitioning with the microspheres equally distributed in the perfused liver, and ii) tumor-clustered partitioning where the microspheres distribution is inferred from the patient specific images. METHODS: Two subjects diagnosed with liver cancer were included in this study. For each subject, abdominal CT scans acquired prior to the SIRT and post-treatment 90Y positron emission tomography were considered. Two microspheres partitionings were simulated namely homogeneous and tumor-clustered partitioning. The homogeneous and tumor-clustered partitionings were derived starting from CT images. The microspheres radiation is simulated by means of Russell's law. RESULTS: In homogenous simulations, the dose delivery is uniform in the whole liver while in the tumor-clustered simulations a heterogeneous distribution of the delivered dose is visible with higher values in the tumor regions. In addition, in the tumor-clustered simulation, the delivered dose is higher in the viable tumor than in the necrotic tumor, for all patients. In the tumor-clustered case, the dose delivered in the non-tumoral tissue (NTT) was considerably lower than in the perfused liver. CONCLUSIONS: The model proposed here represents a proof-of-concept for personalized dosimetry assessment based on preoperative CT images.


Carcinoma, Hepatocellular , Liver Neoplasms , Microspheres , Radiotherapy Dosage , Yttrium Radioisotopes , Liver Neoplasms/radiotherapy , Liver Neoplasms/diagnostic imaging , Carcinoma, Hepatocellular/radiotherapy , Carcinoma, Hepatocellular/diagnostic imaging , Humans , Yttrium Radioisotopes/therapeutic use , Models, Biological , Tomography, X-Ray Computed , Radiation Dosage , Microscopy
6.
Phys Med ; 122: 103390, 2024 Jun.
Article En | MEDLINE | ID: mdl-38833878

PURPOSE: This study discusses the measurement of dose in clinical commissioning tests described in IAEA-TECDOC-1583. It explores the application of Monte Carlo (MC) modelled medium dependency correction factors (Kmed) for accurate dose measurement in bone and lung materials using the CIRS phantom. METHODS: BEAMnrc codes simulate radiation sources and model radiation transport for 6 MV and 15 MV photon beams. CT images of the CIRS phantom are converted to an MC compatible phantom. The PTW 30013 farmer chamber measures doses within modeled CIRS phantom. Kmed are determined by averaging values from four central voxels within the sensitive volume of the farmer chamber. Kmed is calculated for Dm.m and Dw.w algorithm types in bone and lung media for both photon beams. RESULTS: Average modelled correction factors for Dm.m calculations using the farmer chamber are 0.976 (±0.1 %) for 6 MV and 0.979 (±0.1 %) for 15 MV in bone media. Correspondingly, correction factors for Dw.w calculations are 0.99 (±0.3 %) and 0.992 (±0.4 %), respectively. For lung media, average correction factors for Dm.m calculations are 1.02 (±0.3 %) for 6 MV and 1.022 (±0.4 %) for 15 MV. Correspondingly, correction factors for Dw.w calculations are 1.01 (±0.3 %) and 1.012 (±0.2 %), respectively. CONCLUSIONS: This study highlights the significant impact of applying Kmed on dose differences between measurement and calculation during the dose audit process.


Algorithms , Monte Carlo Method , Phantoms, Imaging , Radiation Dosage , Bone and Bones/diagnostic imaging , Humans , Lung/diagnostic imaging , Lung/radiation effects , Radiometry/methods , Radiometry/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Dosage
7.
J Radiol Prot ; 44(2)2024 Jun 12.
Article En | MEDLINE | ID: mdl-38834050

Interventional radiology is a clinical practice with important benefits for patients, but which involves high radiation doses. The optimisation of radiation protection (RP) for paediatric interventional cardiology is a priority for both patients and staff. The use of diagnostic reference levels (DRLs) has been proposed by the International Commission on Radiological Protection to improve RP in imaging procedures. Dose management systems (DMSs) allow the automatic collection of dosimetric, geometric and technical data to assist the optimisation process, with a continuous audit of the procedures, generating alerts to implement corrective actions when necessary. Patient dose indicators may be analysed individually and for different radiation events (fluoroscopy and cine runs). Occupational doses per procedure may be analysed (if electronic dosimeters are available) and linked with patient doses for an integrated approach to RP. Regional optimisation programmes require data collection and processing from several countries to set and periodically update the DRLs. Patient data is anonymised, and each participating hospital has access to their data in a central computer server. Using DMSs may be one of the best ways to support these programs in the collection and analysis of data, raising alerts about high patient and occupational doses and suggesting optimisation actions.


Occupational Exposure , Radiation Dosage , Radiation Protection , Radiation Protection/standards , Humans , Occupational Exposure/prevention & control , Occupational Exposure/analysis , Radiography, Interventional , Radiation Monitoring/methods , Diagnostic Reference Levels , Radiology, Interventional
8.
BMC Med Imaging ; 24(1): 145, 2024 Jun 13.
Article En | MEDLINE | ID: mdl-38872126

BACKGROUND: To compare the diagnostic value of 120-kV with conventional 96-kV Cone-Beam CT (CBCT) of the temporal bone after cochlear implant (CI) surgery. METHODS: This retrospective study included CBCT scans after CI surgery between 06/17 and 01/18. CBCT allowed examinations with 96-kV or 120-kV; other parameters were the same. Two radiologists independently evaluated following criteria on 5-point Likert scales: osseous spiral lamina, inner and outer cochlear wall, semi-circular canals, mastoid trabecular structure, overall image quality, metal and motion artefacts, depiction of intracochlear electrode position and visualisation of single electrode contacts. Effective radiation dose was assessed. RESULTS: Seventy-five patients (females, n = 39 [52.0%], mean age, 55.8 ± 16.5 years) were scanned with 96-kV (n = 32, 42.7%) and 120-kV (n = 43, 57.3%) protocols including CI models from three vendors (vendor A n = 7; vendor B n = 43; vendor C n = 25). Overall image quality, depiction of anatomical structures, and electrode position were rated significantly better in 120-kV images compared to 96-kV (all p < = 0.018). Anatomical structures and electrode position were rated significantly better in 120-kV CBCT for CI models from vendor A and C, while 120-kV did not provide improved image quality in CI models from vendor B. Radiation doses were significantly higher for 120-kV scans compared to 96-kV (0.15 vs. 0.08 mSv, p < 0.001). CONCLUSIONS: 120-kV and 96-kV CBCT provide good diagnostic images for the postoperative CI evaluation. While 120-kV showed improved depiction of temporal bone and CI electrode position compared to 96-kV in most CI models, the 120-kV protocol should be chosen wisely due to a substantially higher radiation exposure.


Cochlear Implants , Cone-Beam Computed Tomography , Radiation Dosage , Temporal Bone , Humans , Cone-Beam Computed Tomography/methods , Male , Middle Aged , Female , Retrospective Studies , Temporal Bone/diagnostic imaging , Aged , Adult , Cochlear Implantation/methods
9.
Eur Radiol Exp ; 8(1): 63, 2024 May 20.
Article En | MEDLINE | ID: mdl-38764066

BACKGROUND: Emphysema influences the appearance of lung tissue in computed tomography (CT). We evaluated whether this affects lung nodule detection by artificial intelligence (AI) and human readers (HR). METHODS: Individuals were selected from the "Lifelines" cohort who had undergone low-dose chest CT. Nodules in individuals without emphysema were matched to similar-sized nodules in individuals with at least moderate emphysema. AI results for nodular findings of 30-100 mm3 and 101-300 mm3 were compared to those of HR; two expert radiologists blindly reviewed discrepancies. Sensitivity and false positives (FPs)/scan were compared for emphysema and non-emphysema groups. RESULTS: Thirty-nine participants with and 82 without emphysema were included (n = 121, aged 61 ± 8 years (mean ± standard deviation), 58/121 males (47.9%)). AI and HR detected 196 and 206 nodular findings, respectively, yielding 109 concordant nodules and 184 discrepancies, including 118 true nodules. For AI, sensitivity was 0.68 (95% confidence interval 0.57-0.77) in emphysema versus 0.71 (0.62-0.78) in non-emphysema, with FPs/scan 0.51 and 0.22, respectively (p = 0.028). For HR, sensitivity was 0.76 (0.65-0.84) and 0.80 (0.72-0.86), with FPs/scan of 0.15 and 0.27 (p = 0.230). Overall sensitivity was slightly higher for HR than for AI, but this difference disappeared after the exclusion of benign lymph nodes. FPs/scan were higher for AI in emphysema than in non-emphysema (p = 0.028), while FPs/scan for HR were higher than AI for 30-100 mm3 nodules in non-emphysema (p = 0.009). CONCLUSIONS: AI resulted in more FPs/scan in emphysema compared to non-emphysema, a difference not observed for HR. RELEVANCE STATEMENT: In the creation of a benchmark dataset to validate AI software for lung nodule detection, the inclusion of emphysema cases is important due to the additional number of FPs. KEY POINTS: • The sensitivity of nodule detection by AI was similar in emphysema and non-emphysema. • AI had more FPs/scan in emphysema compared to non-emphysema. • Sensitivity and FPs/scan by the human reader were comparable for emphysema and non-emphysema. • Emphysema and non-emphysema representation in benchmark dataset is important for validating AI.


Artificial Intelligence , Pulmonary Emphysema , Tomography, X-Ray Computed , Humans , Male , Middle Aged , Female , Tomography, X-Ray Computed/methods , Pulmonary Emphysema/diagnostic imaging , Software , Sensitivity and Specificity , Lung Neoplasms/diagnostic imaging , Aged , Radiation Dosage , Solitary Pulmonary Nodule/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods
10.
BMC Med Imaging ; 24(1): 114, 2024 May 17.
Article En | MEDLINE | ID: mdl-38760689

Digital dental technology covers oral cone-beam computed tomography (CBCT) image processing and low-dose CBCT dental applications. A low-dose CBCT image enhancement method based on image fusion is proposed to address the need for subzygomatic small screw insertion. Specifically, firstly, a sharpening correction module is proposed, where the CBCT image is sharpened to compensate for the loss of details in the underexposed/over-exposed region. Secondly, a visibility restoration module based on type II fuzzy sets is designed, and a contrast enhancement module using curve transformation is designed. In addition to this, we propose a perceptual fusion module that fuses visibility and contrast of oral CBCT images. As a result, the problems of overexposure/underexposure, low visibility, and low contrast that occur in oral CBCT images can be effectively addressed with consistent interpretability. The proposed algorithm was analyzed in comparison experiments with a variety of algorithms, as well as ablation experiments. After analysis, compared with advanced enhancement algorithms, this algorithm achieved excellent results in low-dose CBCT enhancement and effective observation of subzygomatic small screw implantation. Compared with the best performing method, the evaluation metric is 0.07-2 higher on both datasets. The project can be found at: https://github.com/sunpeipei2024/low-dose-CBCT .


Algorithms , Bone Screws , Cone-Beam Computed Tomography , Humans , Cone-Beam Computed Tomography/methods , Zygoma/diagnostic imaging , Radiation Dosage , Image Processing, Computer-Assisted/methods , Radiographic Image Enhancement/methods
12.
J Environ Radioact ; 276: 107446, 2024 Jun.
Article En | MEDLINE | ID: mdl-38733660

Radon presents significant health risks due to its short-lived progeny. The evaluation of the equivalent lung dose coefficient is crucial for assessing the potential health effects of radon exposure. This review focuses on the uncertainty analysis of the parameters associated with the calculation of the equivalent lung dose coefficient attributed to radon inhalation in mines. This analysis is complex due to various factors, such as geological conditions, ventilation rates, and occupational practices. The literature review systematically examines the sources of radon and its health effects among underground miners. It also discusses the human respiratory tract model used to calculate the equivalent lung dose coefficient and the associated parameters leading to uncertainties in the calculated lung dose. Additionally, the review covers the different methodologies employed for uncertainty quantification and their implications on dose assessment. The text discusses challenges and limitations in current research practices and provides recommendations for future studies. Accurate risk assessment and effective safety measures in mining environments require understanding and mitigating parameter uncertainties.


Air Pollutants, Radioactive , Lung , Mining , Occupational Exposure , Radon , Radon/analysis , Humans , Occupational Exposure/analysis , Occupational Exposure/statistics & numerical data , Lung/radiation effects , Uncertainty , Air Pollutants, Radioactive/analysis , Risk Assessment/methods , Radiation Dosage , Radiation Monitoring/methods
13.
J Radiol Prot ; 44(2)2024 May 17.
Article En | MEDLINE | ID: mdl-38722292

According to International Commission of Radiological Protection, the equivalent dose limit for the eye lens for occupational exposure is recommended to be 20 mSv yr-1, averaged over 5 years, with no single year above 50 mSv. Some studies reported the measurement of assistant's lens exposure in diagnostic computed tomography (CT) examinations, but further investigation is still required in the association between the lens dose for assistants and various dose parameters. Therefore, we measured the assistant's lens exposure using small optically stimulated luminescence dosimeters. The type of occupation, type of assistance, total scan time, total mAs, total scan length, and dose-length product (DLP) were recorded and analyzed in association with air kerma at the lens position. The assistance was classified into four types: 'assisted ventilation,' 'head holding,' 'body holding,' and 'raising patient's arm.' The air kerma of lens position was not significantly different for each assistance type (p< 0.05, Kruskal-Wallis test). Further, the lens doses for assistants correlated with DLP, but with various strengths of correlation with the assistance type and were influenced by the distance from the CT gantry. In conclusion, lens dose during assistance and DLP demonstrated the strongest correlation. 'Raising patient's arm' and 'head holding' exhibited stronger correlations, which required less table movement during the CT scan than 'assisted ventilation' and 'body holding'.


Lens, Crystalline , Occupational Exposure , Radiation Dosage , Tomography, X-Ray Computed , Lens, Crystalline/radiation effects , Humans , Occupational Exposure/analysis , Radiation Protection , Radiation Exposure/analysis
14.
Ital J Pediatr ; 50(1): 100, 2024 May 17.
Article En | MEDLINE | ID: mdl-38760836

BACKGROUND: The European-funded Health Effects of Cardiac Fluoroscopy and Modern Radiotherapy in Pediatrics (HARMONIC) project aims to improve knowledge on the effects of medical exposure to ionizing radiation (IR) received during childhood. One of its objectives is to build a consolidated European cohort of pediatric patients who have undergone cardiac catheterization (Cath) procedures, with the goal of enhancing the assessment of long-term radiation-associated cancer risk. The purpose of our study is to provide a detailed description of the Italian cohort contributing to the HARMONIC project, including an analysis of cumulative IR exposure, reduction trend over the years and an overview of the prospective collection of biological samples for research in this vulnerable population. METHODS: In a single-center retrospective cohort study, a total of 584 patients (323 males) with a median age of 6 (2-13) years, referred at the Pediatric Cardiology in Niguarda Hospital from January 2015 to October 2023, were included. Biological specimens from a subset of 60 patients were prospectively collected for biobanking at baseline, immediately post-procedure and after 12 months. RESULTS: Two hundred fifty-nine (44%) patients were under 1 year old at their first procedure. The median KAP/weight was 0.09 Gy·cm2/kg (IQR: 0.03-0.20), and the median fluoroscopy time was 8.10 min (IQR: 4.00-16.25). KAP/weight ratio showed a positive correlation with the fluoroscopy time (Spearman's rho = 0.679, p < 0.001). Significant dose reduction was observed either after implementation of an upgraded technology system and a radiation training among staff. The Italian cohort includes 1858 different types of specimens for Harmonic biobank, including blood, plasma, serum, clot, cell pellet/lymphocytes, saliva. CONCLUSIONS: In the Italian Harmonic cohort, radiation dose in cardiac catheterization varies by age and procedure type. An institution's radiological protection strategy has contributed to a reduction in radiation dose over time. Biological samples provide a valuable resource for future research, offering an opportunity to identify potential early biomarkers for health surveillance and personalized risk assessment.


Cardiac Catheterization , Heart Defects, Congenital , Radiation Exposure , Humans , Italy , Male , Child , Female , Child, Preschool , Adolescent , Retrospective Studies , Radiation Exposure/adverse effects , Fluoroscopy/adverse effects , Radiation Dosage , Cohort Studies
15.
BMC Gastroenterol ; 24(1): 173, 2024 May 18.
Article En | MEDLINE | ID: mdl-38762503

BACKGROUND: There have been previous studies and earlier systematic review on the relationship between inflammatory bowel disease (IBD) and radiation exposure. With the diversification of current test methods, this study intended to conduct a meta-analysis to evaluate the IBD radiation exposure in recent years. METHODS: Three databases (PUBMED, EMBASE, and MEDICINE) for relevant literature up to May 1, 2023 were searched. The statistical data meeting requirements were collated and extracted. RESULTS: 20 papers were enrolled. The overall high radiation exposure rate was 15% (95% CI = [12%, 19%]) for CD and 5% (95% CI = [3%, 7%]) for UC. The pooled result found that high radiation exposure rate was 3.44 times higher in CD than in UC (OR = 3.44, 95% CI = [2.35, 5.02]). Moreover, the average radiation exposure level in CD was 12.77 mSv higher than that in UC (WMD = 12.77, 95% CI = [9.93, 15.62] mSv). Furthermore, radiation exposure level of CD after 2012 was higher than those before 2012 (26.42 ± 39.61vs. 23.76 ± 38.46 mSv, P = 0.016), while UC did not show similar result (11.99 ± 27.66 vs. 10.01 ± 30.76 mSv, P = 0.1). Through subgroup analysis, it was found that disease duration (WMD = 2.75, 95% CI = [0.10, 5.40] mSv), complications (OR = 5.09, 95% CI = [1.50, 17.29]), and surgical history (OR = 5.46, 95% CI = [1.51, 19.69]) significantly increased the proportion of high radiation exposure. CONCLUSION: This study found that radiation exposure level of IBD patients was high, which revealed the radiation risk in the process of diagnosis and treatment of IBD patients. In the future, longer follow-up and prospective studies are needed to reveal the relationship between high radiation exposure and solid tumorigenesis.


Radiation Exposure , Humans , Radiation Exposure/adverse effects , Colitis, Ulcerative , Inflammatory Bowel Diseases , Crohn Disease , Radiation Dosage
16.
Radiology ; 311(2): e231741, 2024 May.
Article En | MEDLINE | ID: mdl-38771176

Performing CT in children comes with unique challenges such as greater degrees of patient motion, smaller and densely packed anatomy, and potential risks of radiation exposure. The technical advancements of photon-counting detector (PCD) CT enable decreased radiation dose and noise, as well as increased spatial and contrast resolution across all ages, compared with conventional energy-integrating detector CT. It is therefore valuable to review the relevant technical aspects and principles specific to protocol development on the new PCD CT platform to realize the potential benefits for this population. The purpose of this article, based on multi-institutional clinical and research experience from pediatric radiologists and medical physicists, is to provide protocol guidance for use of PCD CT in the imaging of pediatric patients.


Photons , Radiation Dosage , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Child , Infant , Pediatrics/methods , Child, Preschool , Practice Guidelines as Topic
17.
J Radiol Prot ; 44(2)2024 May 28.
Article En | MEDLINE | ID: mdl-38722296

The purpose of this study is to evaluate the occupational doses (eye lens, extremities and whole body) in paediatric cardiac interventional and diagnostic catheterization procedures performed in a paediatric reference hospital located in Recife, Pernambuco. For eye lens dosimetry, the results show that the left eye receives a higher dose than the right eye, and there is a small difference between the doses received during diagnostic (D) and therapeutic (T) procedures. The extrapolated annual values for the most exposed eye are close to the annual limit. For doses to the hands, it was observed that in a significant number of procedures (37 out of 45 therapeutic procedures, or 82%) at least one hand of the physician was exposed to the primary beam. During diagnostic procedures, the physician's hand was in the radiation field in 11 of the 17 catheterization procedures (65%). This resulted in a 10-fold increase in dose to the hands. The results underscore the need for optimization of radiation safety and continued efforts to engage staff in a radiation safety culture.


Occupational Exposure , Radiation Dosage , Humans , Occupational Exposure/analysis , Child , Cardiac Catheterization , Radiation Protection , Lens, Crystalline/radiation effects , Radiography, Interventional , Radiation Exposure/analysis
18.
J Gastroenterol ; 59(6): 437-441, 2024 06.
Article En | MEDLINE | ID: mdl-38703187

Fluoroscopy-guided gastrointestinal procedures, including gastrointestinal stenting, balloon-assisted endoscopy (BAE), endoscopic retrograde cholangiopancreatography (ERCP), and endoscopic ultrasound (EUS), are essential for diagnosis and treatment in gastroenterology. Such procedures involve radiation exposure that necessitates strict safety measures to protect patients, doctors, and medical staff. The April 2020 update to Japan's Ionizing Radiation Injury Prevention Regulations for occupational exposure reduced the lens exposure dose limit to approximately one-seventh of its previous level. This change highlights the need for improved safety protocols. Without adaptation, the sustainability of fluoroscopy-based endoscopic techniques could be at risk due to the potential to exceed these new limits. This review examines the current state of medical radiation exposure in the field of gastroenterology in Japan and discusses the findings of the REX-GI study.


Gastroenterology , Occupational Exposure , Radiation Exposure , Radiation Protection , Humans , Japan , Gastroenterology/methods , Gastroenterology/standards , Occupational Exposure/prevention & control , Occupational Exposure/adverse effects , Radiation Protection/methods , Radiation Exposure/prevention & control , Radiation Exposure/adverse effects , Fluoroscopy/adverse effects , Fluoroscopy/methods , Radiation Injuries/prevention & control , Radiation Dosage
19.
J Breast Imaging ; 6(3): 261-270, 2024 May 27.
Article En | MEDLINE | ID: mdl-38703091

OBJECTIVE: To determine cancer visualization utility and radiation dose for non-implant-displaced (ID) views using standard protocol with digital breast tomosynthesis (DBT) vs alternative protocol with 2D only when screening women with implant augmentation. METHODS: This retrospective cohort study identified women with implants who underwent screening DBT examinations that had abnormal findings from July 28, 2014, to December 31, 2021. Three fellowship-trained breast radiologists independently reviewed examinations retrospectively to determine if the initially identified abnormalities could be visualized on standard protocol (DBT with synthesized 2D (S2D) for ID and non-ID views) and alternate protocol (DBT with S2D for ID and only the S2D images for non-ID views). Estimated exam average glandular dose (AGD) and associations between cancer visualization with patient and implant characteristics for both protocols were evaluated. RESULTS: The study included 195 patients (mean age 55 years ± 10) with 223 abnormal findings. Subsequent biopsy was performed for 86 abnormalities: 59 (69%) benign, 8 (9%) high risk, and 19 (22%) malignant. There was no significant difference in malignancy visualization rate between standard (19/223, 8.5%) and alternate (18/223, 8.1%) protocols (P = .92), but inclusion of the DBT for non-ID views found one additional malignancy. Total examination AGD using standard protocol (21.9 mGy ± 5.0) was significantly higher than it would be for estimated alternate protocol (12.6 mGy ± 5.0, P <.001). This remained true when stratified by breast thickness: 6.0-7.9 cm, 8.0-9.9 cm, >10.0 cm (all P <.001). CONCLUSION: The inclusion of DBT for non-ID views did not significantly increase the cancer visualization rate but did significantly increase overall examination AGD.


Breast Neoplasms , Mammography , Humans , Female , Middle Aged , Retrospective Studies , Breast Neoplasms/diagnostic imaging , Mammography/methods , Breast Implants/adverse effects , Radiation Dosage , Breast/diagnostic imaging , Breast/pathology , Aged , Early Detection of Cancer/methods , Adult
20.
Phys Med Biol ; 69(11)2024 May 30.
Article En | MEDLINE | ID: mdl-38718814

Objective.To evaluate the feasibility of using a deep learning dose prediction approach to identify patients who could benefit most from proton therapy based on the normal tissue complication probability (NTCP) model.Approach.Two 3D UNets were established to predict photon and proton doses. A dataset of 95 patients with localized prostate cancer was randomly partitioned into 55, 10, and 30 for training, validation, and testing, respectively. We selected NTCP models for late rectum bleeding and acute urinary urgency of grade 2 or higher to quantify the benefit of proton therapy. Propagated uncertainties of predicted ΔNTCPs resulting from the dose prediction errors were calculated. Patient selection accuracies for a single endpoint and a composite evaluation were assessed under different ΔNTCP thresholds.Main results.Our deep learning-based dose prediction technique can reduce the time spent on plan comparison from approximately 2 days to as little as 5 seconds. The expanded uncertainty of predicted ΔNTCPs for rectum and bladder endpoints propagated from the dose prediction error were 0.0042 and 0.0016, respectively, which is less than one-third of the acceptable tolerance. The averaged selection accuracies for rectum bleeding, urinary urgency, and composite evaluation were 90%, 93.5%, and 93.5%, respectively.Significance.Our study demonstrates that deep learning dose prediction and NTCP evaluation scheme could distinguish the NTCP differences between photon and proton treatment modalities. In addition, the dose prediction uncertainty does not significantly influence the decision accuracy of NTCP-based patient selection for proton therapy. Therefore, automated deep learning dose prediction and NTCP evaluation schemes can potentially be used to screen large patient populations and to avoid unnecessary delays in the start of prostate cancer radiotherapy in the future.


Automation , Deep Learning , Prostatic Neoplasms , Proton Therapy , Radiotherapy Dosage , Humans , Male , Prostatic Neoplasms/radiotherapy , Proton Therapy/adverse effects , Proton Therapy/methods , Radiation Dosage , Radiotherapy Planning, Computer-Assisted/methods , Decision Support Systems, Clinical , Organs at Risk/radiation effects , Probability , Uncertainty
...