Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 90
Filter
1.
Arq Bras Oftalmol ; 88(1): e20230103, 2024.
Article in English | MEDLINE | ID: mdl-39109740

ABSTRACT

PURPOSE: This study aimed to compare the safety and effectiveness of intraocular pressure reduction between micropulse transscleral cyclophotocoagulation and "slow cook" transscleral cyclophotocoagulation in patients with refractory primary open-angle glaucoma. METHODS: We included patients with primary open angle glaucoma with at least 12 months of follow-up. We collected and analyzed data on the preoperative characteristics and postoperative outcomes. The primary outcomes were a reduction of ≥20% of the baseline value (criterion A) and/or intraocular pressure between 6 and 21 mmHg (criterion B). RESULTS: We included 128 eyes with primary open-angle glaucoma. The preoperative mean intraocular pressure was 25.53 ± 6.40 and 35.02 ± 12.57 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The mean intraocular pressure was reduced significantly to 14.33 ± 3.40 and 15.37 ± 5.85 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups at the last follow-up, respectively (p=0.110). The mean intraocular pressure reduction at 12 months was 11.20 ± 11.46 and 19.65 ± 13.22 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The median preoperative logMAR visual acuity was 0.52 ± 0.69 and 1.75 ± 1.04 in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The mean visual acuity variation was -0.10 ± 0.35 and -0.074 ± 0.16 in the micropulse- and "slow cook" transscleral cyclophotocoagulation, respectively (p=0.510). Preoperatively, the mean eye drops were 3.44 ± 1.38 and 2.89 ± 0.68 drugs in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p=0.017), but those were 2.06 ± 1.42 and 1.02 ± 1.46 at the end of the study in the "slow cook" and micropulse transscleral cyclophotocoagulation groups, respectively (p<0.001). The success of criterion A was not significant between both groups. Compared with 11 eyes (17.74%) in the "slow cook" transscleral cyclophotocoagulation group, 19 eyes (28.78%) in the micropulse transscleral cyclophotocoagulation group showed complete success (p=0.171). For criterion B, 28 (42.42%) and 2 eyes (3.22%) showed complete success after micropulse- and "slow cook" transscleral cyclophotocoagulation, respectively (p<0.001). CONCLUSION: Both techniques reduced intraocular pressure effectively.


Subject(s)
Glaucoma, Open-Angle , Intraocular Pressure , Laser Coagulation , Lasers, Semiconductor , Sclera , Humans , Glaucoma, Open-Angle/surgery , Glaucoma, Open-Angle/physiopathology , Intraocular Pressure/physiology , Female , Male , Middle Aged , Treatment Outcome , Laser Coagulation/methods , Aged , Lasers, Semiconductor/therapeutic use , Sclera/surgery , Visual Acuity , Adult , Follow-Up Studies , Postoperative Period , Ciliary Body/surgery , Time Factors
2.
Curr Eye Res ; 49(10): 1068-1073, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38856046

ABSTRACT

PURPOSE: This study describes a prototype developed for aphakia without capsular support (AWCS) and its proof of concept. METHODS: This descriptive study used a 3D software to create and analyze virtual prototypes before manufacturing. A nylon-6/nylon-6.6 copolymer filament and a 3D printer were used for prototyping. A device implantation technique was developed using a 23-gauge hypodermic needle. Two opposing markings, 2 mm posterior to the limbus, were made to determine the location of the scleral punctures and the final position of the device. After adequate centralization and positioning of the device, its haptics were cut and cauterized to generate thermal modeling of the extremity and allow the thickening of the tips (flange), serving as an anchoring mechanism to the sclera. The efficacy and adequacy of the technique and device were then evaluated. RESULTS: Vitreous tissue extrusion was not observed during the sclerotomy. The device was well fixed to the sclera; however, adequate IOL stability and centralization still needed to be achieved. The surgeon evaluated the adequacy of all the other devices' characteristics. CONCLUSIONS: The development of a technology prototype for correcting AWCS was possible. Although the proposed prototype met most of the established concept guidelines, the stability of the IOL position remains challenging.


Subject(s)
Aphakia, Postcataract , Humans , Aphakia, Postcataract/surgery , Aphakia, Postcataract/physiopathology , Lens Capsule, Crystalline/surgery , Lenses, Intraocular , Sclerostomy , Lens Implantation, Intraocular/methods , Sclera/surgery , Aphakia/surgery , Printing, Three-Dimensional , Prosthesis Design , Visual Acuity/physiology
3.
J Cataract Refract Surg ; 50(5): 505-510, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38651698

ABSTRACT

PURPOSE: To compare flange depth for a modified scleral pocket (SP) vs no scleral pocket (NSP) technique (Yamane technique) for intrascleral intraocular lens (IOL) fixation. SETTING: Instituto de Oftalmología Santa Fe, Santa Fe, Argentina. DESIGN: Prospective, randomized, single-surgeon, observational study. METHODS: Eyes with aphakia and no capsular support were included. They were divided into 2 groups: one was programmed for a double-needle flanged intrascleral IOL fixation as originally described by Shin Yamane with NSP and the second group had a modified SP technique. Flange depth was measured with anterior-segment optical coherence tomography (AS-OCT) at 1 month, 3 months, 6 months, and 12 months postoperatively, and the results were compared. RESULTS: Each group comprised 18 eyes of 18 patients, giving a total of 36 flanges per group. The groups were comparable preoperatively. At 12 months, uncorrected distance visual acuity and corrected distance visual acuity (CDVA) were not statistically different for both groups (P = .333; P = .448). Spherical equivalent (SEQ) was not significantly different between groups at 12 months postoperatively (P = .078). AS-OCT revealed a significantly deeper flange position for the SP group at 1 month, 3 months, 6 months, and 12 months postoperatively (P < .05). CONCLUSIONS: When performing a double-needle intrascleral IOL fixation in aphakic eyes with no capsular support, a modified scleral pocket technique provides a significantly deeper flange position with no difference in CDVA or SEQ 12 months postoperatively.


Subject(s)
Lens Implantation, Intraocular , Lenses, Intraocular , Sclera , Tomography, Optical Coherence , Visual Acuity , Humans , Sclera/surgery , Lens Implantation, Intraocular/methods , Prospective Studies , Visual Acuity/physiology , Female , Male , Middle Aged , Aged , Aphakia, Postcataract/surgery , Aphakia, Postcataract/physiopathology , Surgical Flaps , Suture Techniques , Pseudophakia/physiopathology , Refraction, Ocular/physiology
4.
Arq Bras Oftalmol ; 87(2): e20220046, 2024.
Article in English | MEDLINE | ID: mdl-38451677

ABSTRACT

The creation of a scleral flap during trabeculectomy can be complicated by a buttonhole, partial amputation at the limbus, and extensive thinning. In some cases, the procedure must be aborted to prevent more serious postoperative complications. This report describes a technique of converting complicated trabeculectomy into ab externo cyclodialysis. A 41-year-old patient with congenital glaucoma presented with a perforated scleral wall with the choroidal tissue exposed during the dissection of the partial-thickness scleral flap. By using a Barraquer cyclodialysis spatula through the scleral perforation, the choroid was separated from the sclera up to the scleral spur over 30° into the anterior chamber. The sclera and conjunctiva/Tenon were sutured with 10-0 nylon single sutures. Two months later, the intraocular pressure was reduced to 16 mmHg with no hypotensive topical medications. This case illustrates an alternative approach to managing a flap-related perioperative complication in trabeculectomy, which yielded good early results.


Subject(s)
Glaucoma , Trabeculectomy , Humans , Adult , Trabeculectomy/adverse effects , Sclera/surgery , Anterior Chamber , Conjunctiva/surgery , Antihypertensive Agents , Glaucoma/surgery
5.
Arq Bras Oftalmol ; 87(2): e20220306, 2024.
Article in English | MEDLINE | ID: mdl-38451682

ABSTRACT

PURPOSE: As superotemporal implantation of the Ahmed glaucoma valve is not always feasible in cases of refractory glaucoma, this study examined the characteristics and surgical outcomes of cases in which the valve was implanted in a nonsuperotemporal quadrant using a modified long scleral tunnel technique. METHODS: This retrospective case-control study included 37 eyes with nonsuperotemporal quadrant--Ahmed glaucoma valve implantation in Group 1 and 69 eyes with superotemporal Ahmed glaucoma valve implantation in Group 2. The demographic characteristics of these groups, surgical outcomes, including complications, further surgical interventions, and surgical success rates were compared. Surgical success was defined as an intraocular pressure not exceeding 21 mmHg, accompanied by a minimum reduction of 20% in intraocular pressure from the baseline without any additional intraocular pressure-lowering procedures, and the absence of light perception loss or phthisis bulbi. RESULTS: Group 1 had significantly higher numbers of eyes with secondary glaucoma and preoperative surgical procedures than Group 2 (p<0.05). Both groups had mean preoperative intraocular pressure values, and mean intraocular pressure values at the last visit of 34.2 and 27.9 months, 35.5 ± 1.5 and 35.8 ± 1.2 mmHg, and 14.5 ± 5 and 14.9 mmHg, respectively. Although both groups had 70.2% and 75.8% as their five-year cumulative probability of success, respectively, the rates of complications, revisional surgery, and additional surgical procedures did not differ significantly (p>0.05). CONCLUSION: The modified long scleral tunnel technique for Ahmed glaucoma valve implantation in nonsuperotemporal quadrants achieves intraocular pressure control and complication rates comparable to superotemporal implantation.


Subject(s)
Glaucoma , Intraocular Pressure , Humans , Case-Control Studies , Retrospective Studies , Glaucoma/surgery , Sclera/surgery
6.
J Glaucoma ; 32(8): 695-700, 2023 08 01.
Article in English | MEDLINE | ID: mdl-37172013

ABSTRACT

PRCIS: Slow-coagulation CW-TSCPC is an efficacious, relatively safe, and non-incisional laser treatment option as an initial surgical glaucoma management choice, in secondary aphakic adult glaucoma that is medically uncontrolled. PURPOSE: This study evaluates the outcomes of slow-coagulation continuous wave transscleral cyclophotocoagulation (CW-TSCPC) laser for treating secondary aphakic adult glaucoma after complicated cataract surgery as a primary surgical intervention. MATERIALS AND METHODS: A retrospective chart review of adult aphakic eyes with medically uncontrolled glaucoma underwent slow-coagulation CW-TSCPC as a primary surgical glaucoma intervention was performed. Surgical success was the primary outcome measure. Success was defined as postoperative intraocular pressure (IOP) between 6 and 21 mm Hg with ≥20% reduction compared with baseline and no need for further glaucoma surgeries or development of vision-threatening complications. The secondary outcomes included changes in IOP, glaucoma medication numbers, visual acuity, and postoperative complications during the first year after laser treatment after laser treatment. RESULTS: This study included 41 eyes of 41 patients. The mean age of study participants was 66.7±13.1 years, with a mean follow-up duration of 19±3.5 months. At one year, the success rate was 63.4%. A statistically significant reduction of the IOP was observed, with the mean IOP decreasing from 29.6±5.8 mm Hg with a mean of 3.9±1.0 medications at baseline to a mean of 19.0±6.4 mm Hg with a mean of 2.5±1.2 medications at 12 months ( P <0.001). Four eyes received CW-TSCPC retreatment, and 2 eyes required incisional glaucoma surgeries. Reported postoperative complications included: visual acuity decline ≥2 lines in 7 eyes, iritis in 6 eyes, hyphema in 5 eyes, cystoid macular edema in 2 eyes, and transient hypotony in 1 eye. CONCLUSION: Slow-coagulation CW-TSCPC is an efficacious, relatively safe, and non-incisional laser treatment option as an initial surgical glaucoma management choice, in secondary aphakic adult glaucoma that is medically uncontrolled.


Subject(s)
Glaucoma , Intraocular Pressure , Humans , Adult , Middle Aged , Aged , Retrospective Studies , Laser Coagulation , Treatment Outcome , Glaucoma/complications , Glaucoma/surgery , Ciliary Body/surgery , Sclera/surgery
7.
J Cataract Refract Surg ; 49(6): 565-570, 2023 06 01.
Article in English | MEDLINE | ID: mdl-36745851

ABSTRACT

PURPOSE: To assess the long-term (5-year) results and complications of the double-flanged polypropylene technique in patients with capsular tension segment fixation, nonfoldable intraocular lens (IOL) scleral fixation, and foldable IOL scleral fixation. SETTING: Santa Casa de Belo Horizonte and Centro Oftalmológico de Minas Gerais. DESIGN: Prospective case series. METHODS: Eyes that underwent treatment using the double-flanged polypropylene technique between September 2016 to September 2021 were included. LogMAR visual acuity was recorded, as well as complications such as long-term polypropylene resistance, conjunctival erosion, conjunctival inflammation, flange exposure, internalization, endophthalmitis, retinal detachment, and cystoid macular edema. RESULTS: 71 eyes of 61 patients were evaluated. The mean follow-up period for these eyes was 28.2 ± 14.3 (min: 4; max: 60; median: 26) months. 173 flanges were performed. 13 cases with sub-Tenon flanges (7.5%) were observed. 5 exposed flanges (2.89%), presented after a mean of 1.8 weeks postoperatively, were observed. 1 patient with large flanges presented with conjunctival inflammation and hyperemia. 2 late internalized flanges (1.1%) and 2 recently internalized flanges (1.1%) were observed. 3 eyes (4.22%) had retinal detachment. Moreover, cystoid macular edema was detected in 3 eyes (4.22%). No cases of endophthalmitis were observed. CONCLUSIONS: The double-flanged technique was proven to be stable when the correct technical procedure was followed. However, complications can be observed, especially with short scleral tunnels and in eyes where the flanges were not buried inside the sclera.


Subject(s)
Endophthalmitis , Lenses, Intraocular , Macular Edema , Retinal Detachment , Humans , Lens Implantation, Intraocular/methods , Polypropylenes , Retinal Detachment/surgery , Sclera/surgery , Endophthalmitis/surgery , Inflammation , Retrospective Studies , Suture Techniques , Postoperative Complications/surgery
8.
Arq Bras Oftalmol ; 86(5): e20230060, 2023.
Article in English | MEDLINE | ID: mdl-35544930

ABSTRACT

A 38-year-old patient who developed aphakia and aniridia secondary to trauma suffered from vision loss. To improve her vision, an iris-intraocular lens complex (Reper®) was fixed to the sclera with Canabrava's double-flanged technique. There was a satisfactory increase in the patient's visual acuity and no complications were observed during the 6-months follow-up. Canabrava technique simplifies and improves the fixation of the iris-intraocular lens complex to the sclera. It is a safe option that does not require scleral flaps or knots.


Subject(s)
Lens Implantation, Intraocular , Lenses, Intraocular , Humans , Female , Adult , Lens Implantation, Intraocular/methods , Sclera/surgery , Suture Techniques , Iris/surgery , Retrospective Studies
9.
Arq Bras Oftalmol ; 86(2): 113-120, 2023.
Article in English | MEDLINE | ID: mdl-35417514

ABSTRACT

PURPOSE: To evaluate the stability and efficacy of the double-flanged 5-0 polypropylene suture to fixate subluxated cataracts at 18 months and the possible complications of this new technique. METHODS: This technique uses a 5-0 polypropylene monofilament to create two flanges with a thermocautery, for fixation of a capsular tension segment to the sclera to fix the subluxated capsular bag. This technique was implemented in 17 eyes requiring intraocular lens implantation in a setting of zonular dialysis due to trauma, Marfan syndrome, microspherophakia, idiopathic disease, and post-phacoemulsification status. RESULTS: Follow-up of the patients occurred at 18 months. Best-corrected visual acuity improved significantly from 0.85 to 0.39 (logMAR), whereas the spherical and cylindrical refractive errors and intraocular pressure remained stable from preoperation. No suture photodegradation or pseudophacodonesis were detected. CONCLUSION: The double-flanged 5-0 polypropylene suture transscleral bag fixation technique has shown favorable long-term outcomes in terms of bag intraocular lens/complex fixation and stability. In eyes with zonular weakness or dialysis, this technique appears to be a safe and knotless option for cataract surgery.


Subject(s)
Cataract Extraction , Cataract , Lens Capsule, Crystalline , Lenses, Intraocular , Humans , Polypropylenes , Lens Capsule, Crystalline/surgery , Cataract Extraction/adverse effects , Lenses, Intraocular/adverse effects , Sclera/surgery , Suture Techniques/adverse effects , Retrospective Studies
11.
Eur J Ophthalmol ; 32(1): 704-708, 2022 Jan.
Article in English | MEDLINE | ID: mdl-33779334

ABSTRACT

PURPOSE: To describe a modified ab interno technique for the tube implantation from a glaucoma draining device into the ciliary sulcus. MATERIALS AND METHODS: The modified ab interno technique was performed on four eyes of four patients. RESULTS: After the plate was fixed, a 21G needle is inserted through a paracentesis 180° away from the tube position into the anterior chamber and advanced to the posterior chamber through the sclera; finally, the needle exits the eye, then the tube is inserted into the lumen of the needle. The tube is then inserted simultaneously as the 21G needle is pulled out so the tube is placed on the ciliary sulcus. CONCLUSIONS: We report a simple and novel technique for the tube implantation from a glaucoma draining device into the ciliary sulcus, in which the tube is guided with a 21G needle from an accessory paracentesis in order to achieve a posterior placement of the tube.


Subject(s)
Glaucoma Drainage Implants , Glaucoma , Anterior Chamber , Glaucoma/surgery , Humans , Intraocular Pressure , Needles , Sclera/surgery
12.
Rev. bras. oftalmol ; 81: e0013, 2022. graf
Article in English | LILACS | ID: biblio-1365727

ABSTRACT

ABSTRACT To report a series of three cases (four eyes) of scleral necrosis after pterygium excision, in which the tarsoconjunctival flap technique was used as treatment. Three patients who progressed to scleral necrosis after surgical pterygium excision were selected. The first patient underwent excision using the bare sclera technique and developed scleral thinning in the immediate postoperative period. The second and third patients received beta irradiation and had late onset scleral necrosis. The tarsoconjunctival flap technique was performed by the same surgeon. Recovery was satisfactory from both anatomical and functional perspectives in all cases, and the technique was considered effective and safe. Although there are only few reports about this technique in the literature, it can be considered as a good alternative to treat scleral necrosis.


RESUMO O objetivo deste estudo foi relatar uma série de três casos (quatro olhos) de necrose escleral pós-exérese de pterígio, em que se utilizou como tratamento a técnica de retalho tarsoconjuntival. Foram selecionados três pacientes que evoluíram para necrose escleral após tratamento cirúrgico de exérese de pterígio: o primeiro caso após técnica de esclera nua, com evolução para afinamento escleral no pós-operatório imediato; o segundo e o terceiro fizeram uso de betaterapia e apresentaram necrose escleral tardiamente. A técnica de recobrimento tarsoconjuntival foi executada pelo mesmo cirurgião. A recuperação foi satisfatória em todos os casos, do ponto de vista anatômico e funcional, sendo eficiente e segura. Apesar das escassas menções na literatura, essa técnica pode ser considerada uma boa alternativa para tratamento da necrose escleral.


Subject(s)
Humans , Male , Female , Adult , Aged , Postoperative Complications/etiology , Surgical Flaps , Pterygium/surgery , Scleral Diseases/surgery , Necrosis , Sclera/surgery , Scleral Diseases/etiology , Conjunctiva/transplantation
13.
Surv Ophthalmol ; 66(4): 594-611, 2021.
Article in English | MEDLINE | ID: mdl-33422510

ABSTRACT

The onset of scleral necrosis after ocular surgery may have catastrophic ocular and systemic consequences. The two most frequent surgeries causing surgically-induced scleral necrosis (SISN) are pterygium excision and cataract extraction. Several pathogenic mechanisms are involved in surgically induced scleral necrosis. All of them are poorly understood. Ocular trauma increasing lytic action of collagenases with subsequent collagen degradation, vascular disruption leading to local ischemia, and immune complex deposition activating the complement system represents some of the events that lead to scleral necrosis. The complex cascade of events involving different pathogenic mechanisms and the patient's abnormal immune response frequently leads to delayed wound healing that predisposes the development of scleral necrosis. The management of SISN ranges from short-term systemic anti-inflammatory drugs to aggressive immunosuppressive therapy and surgical repair. Therefore, before performing any ocular surgery involving the sclera, a thorough ophthalmic and systemic evaluation must be done to identify high-risk patients that may develop SISN.


Subject(s)
Pterygium , Scleritis , Humans , Necrosis/complications , Necrosis/pathology , Sclera/surgery , Scleritis/drug therapy , Scleritis/etiology , Scleritis/pathology , Transplantation, Autologous/adverse effects
14.
J Cataract Refract Surg ; 47(9): 1234-1236, 2021 Sep 01.
Article in English | MEDLINE | ID: mdl-32991503

ABSTRACT

A 6-0 polypropylene suture was introduced in the eye through an ophthalmic viscosurgical device syringe in a completely closed system. The procedure was used to correct optic capture of the intraocular lens by the pupil after 2 cases of Yamane technique.


Subject(s)
Lens Implantation, Intraocular , Lenses, Intraocular , Humans , Sclera/surgery , Suture Techniques , Sutures , Visual Acuity
15.
J Cataract Refract Surg ; 47(2): 265-269, 2021 Feb 01.
Article in English | MEDLINE | ID: mdl-32675655

ABSTRACT

A 29-gauge model test fine needle is used to create a beveled intrascleral tunnel; with microforceps, a 6-0 polypropylene suture is placed in the bore of the needle, which is used as a guide to pass and externalize the monofilament through the sclera. This maneuver is repeated by passing the suture ends through the intraocular lens (IOL) eyelets. The folded IOL is inserted and centered, the sutures are cut, and the flanges are created by thermocautery and inserted into the scleral tunnel. This technique was performed on 7 patients and visual acuity was recorded. The 4-flanged technique for scleral fixation using a 4-eyelet IOL was an effective and a safe treatment in the setting of aphakia.


Subject(s)
Aphakia , Lenses, Intraocular , Aphakia/surgery , Humans , Lens Implantation, Intraocular , Sclera/surgery , Suture Techniques , Sutures
16.
Eur J Ophthalmol ; 31(3): NP65-NP69, 2021 May.
Article in English | MEDLINE | ID: mdl-32400189

ABSTRACT

OBJECTIVE: To present the surgical outcome of posterior chamber intraocular lens scleral fixation using a 27-gauge trocar-assisted transconjunctival sutureless technique in aphakic patients due to cataract surgery complications with inadequate capsular support. METHODS: Six consecutive patients with aphakia due to cataract surgery complications with inadequate capsular bag support were operated by two surgeons. Intraocular lens scleral fixation was performed with a 27-gauge trocar-assisted transconjunctival sutureless technique. Patients were followed-up for 12 months. Preoperative and postoperative best-corrected visual acuities were assessed with Early Treatment Diabetic Retinopathy Study charts and expressed in decimals. RESULTS: All patients showed statistically significant best-corrected visual acuity improvement and excellent anatomic results. Mean preoperative best-corrected visual acuity was 0.17 (range of 0.1-0.2). Mean postoperative best-corrected visual acuity was 0.84 (range of 0.63-1.00). Mean initial spherical equivalent refractive error was +11.85 (range of +9.00 to +15.00). Mean final spherical equivalent refractive error was -0.25 (range of -1.25 to +2.25). There were no postoperative complications during the whole follow-up. CONCLUSION: Fixation of a posterior chamber intraocular lens using a 27-gauge trocar-assisted transconjunctival sutureless intrascleral technique is an excellent option for aphakic patients secondary to cataract surgery complications with inadequate capsular support.


Subject(s)
Lens Implantation, Intraocular , Lenses, Intraocular , Humans , Postoperative Complications , Retrospective Studies , Sclera/surgery , Surgical Instruments , Suture Techniques , Vitrectomy
17.
Arq. bras. oftalmol ; Arq. bras. oftalmol;83(6): 547-551, Nov.-Dec. 2020. graf
Article in English | LILACS | ID: biblio-1153077

ABSTRACT

ABSTRACT This article reports a combined technique of sutureless intrascleral fixated intraocular lens implantation and Descemet membrane endothelial keratoplasty in a patient with anterior pseudophakic bullous keratopathy. Two scleral tunnels were created, corneal incisions were made, and a foldable intraocular lens was cut and removed from the anterior chamber. After performing anterior vitrectomy, a 3-piece foldable intraocular lens was implanted into the anterior chamber. One of the intraocular lens haptics was grasped with a forceps and pulled out from the scleral tunnel. Then, the end of the haptic was cauterized. Similar maneuvers were applied for the other haptic. Next, an 8-mm-diameter donor tissue was prepared, and the recipient endothelial tissue was peeled and removed from the center of the recipient cornea. The prepared donor tissue was injected into the anterior chamber. After proper opening and placement of the donor tissue, an air bubble was injected below the tissue. There were no postoperative complications during the 1-month follow-up.


RESUMO Relato de uma técnica que combina o implante de uma lente intraocular com fixação intraescleral sem sutura e uma ceratoplastia endotelial da membrana de Descemet em paciente com ceratopatia bolhosa pseudofácica anterior. Foram criados dois túneis esclerais. Foram feitas incisões na córnea e a lente intraocular dobrável foi cortada e removida da câmara anterior. Foi então efetuada uma vitrectomia anterior e uma lente intraocular dobrável de 3 peças foi implantada na câmara anterior. Um dos hápticos da lente intraocular foi pinçado com um fórceps e puxado para fora do túnel escleral. A extremidade do háptico foi cauterizada. Manobras semelhantes foram feitas no outro háptico. Foi preparado um tecido de doador com 8 mm de diâmetro e o tecido endotelial da área receptora foi removido do centro da córnea. O tecido preparado do doador foi injetado na câmara anterior. Após abertura e posicionamento adequados do tecido do doador, foi injetada uma bolha de ar abaixo do tecido. Não foi observada nenhuma complicação pós-operatória durante um mês de acompanhamento.


Subject(s)
Humans , Female , Aged , Corneal Transplantation , Lenses, Intraocular , Sclera/surgery , Surgical Instruments , Lens Implantation, Intraocular , Descemet Membrane
18.
J Glaucoma ; 29(7): 598-603, 2020 07.
Article in English | MEDLINE | ID: mdl-32398591

ABSTRACT

Micropulse transscleral cyclophotocoagulation is a promising and relatively new technique that uses repetitive micropulses of diode laser energy, delivered with the Cyclo G6 Glaucoma Laser System (Iridex Corporation), in an off-and-on cyclical manner. This review article provides an update on the latest data available for this technique, including a discussion of the aspects in which there is still limited data, such as the precise mechanism of action, the ideal laser parameters based on total energy levels, as well as an overview of other potentially relevant variables that may be playing an important role in outcomes.


Subject(s)
Ciliary Body/surgery , Glaucoma/surgery , Laser Coagulation , Lasers, Semiconductor/therapeutic use , Humans , Intraocular Pressure , Laser Coagulation/methods , Sclera/surgery , Treatment Outcome
19.
Acta Diabetol ; 57(10): 1151-1157, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32300875

ABSTRACT

AIMS: Intraoperative complications in cataract surgery are more common in diabetic patients. Solving aphakia in these circumstances remains a challenge, as the scleral structure has been shown to be different in diabetes. This study aims to analyze the role of a secondary sutureless scleral intraocular lens (IOL) flanged fixation in diabetic patients without capsular support and to compare the anatomical and functional outcomes using a 30 gauge (G) ultrathin wall needle vs. a 27G needle. METHODS: Retrospective, observational cohort study. 105 eyes (105 patients) who underwent PPV with secondary IOL fixation using a sutureless 27G (n = 51) or a 30G ultrathin wall (UTW) needle technique (n = 54) and had a 24 months postoperative follow up. Consecutive patients' records were reviewed for lens stability and centration parameters, intra- and postoperative complications at 7 days, 1, 3, 6, 12, and 24 months after surgery. Correlations between outcome measures and needle size (27G vs. 30G UTW) were analyzed. RESULTS: IOL displacement occurred in 30 patients (41.2%) in the 27G group and did not occur in the 30G UTW needle group (p < 0.001). Mean time until IOL displacement was 10.5 ± 7.0 months (range: 7 days-24 months). IOL centricity was significantly better in the 30G ultrathin wall needle group compared to 27 G (p = 0.001). Additional surgical interventions were necessary only in the 27G group (n = 14). CONCLUSIONS: Sutureless IOL flanged technique using a 30G UTW needle is more predictable and has less complications in aphakic diabetic patients, compared to a 27G needle technique.


Subject(s)
Diabetes Mellitus/surgery , Diabetic Retinopathy/surgery , Lens Implantation, Intraocular/instrumentation , Needles , Sutureless Surgical Procedures/instrumentation , Adult , Aged , Aphakia/epidemiology , Aphakia/surgery , Argentina/epidemiology , Cohort Studies , Diabetes Mellitus/epidemiology , Diabetic Retinopathy/epidemiology , Equipment Design , Female , Follow-Up Studies , Humans , Lens Implantation, Intraocular/adverse effects , Lens Implantation, Intraocular/methods , Lenses, Intraocular , Male , Middle Aged , Needles/adverse effects , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Retrospective Studies , Sclera/surgery , Sutureless Surgical Procedures/adverse effects , Sutureless Surgical Procedures/methods , Visual Acuity
20.
J Cataract Refract Surg ; 46(3): 333-339, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32079842

ABSTRACT

A new technique for fixating the capsular bag in patients with ectopia lentis is presented. In this technique, the capsulorhexis is performed using a femtosecond laser, followed by the insertion of a standard capsular tension ring to redistribute capsular forces. The nucleus is hydroprolapsed into the anterior chamber and nuclear disassembly is performed above the iris plane to reduce zonular stress. Finally, a 5-0 polypropylene monofilament is used to fixate a capsular tension segment and subluxated capsular bag. This novel double-flanged method, achieved with cautery, does not require direct suturing of the monofilament on the sclera. This article describes the use of this new technique in 3 eyes, 2 in patients with Marfan syndrome and 1 in a patient with microspherophakia.


Subject(s)
Capsulorhexis/methods , Corneal Diseases/surgery , Ectopia Lentis/surgery , Glaucoma/surgery , Iris/abnormalities , Marfan Syndrome/surgery , Phacoemulsification/methods , Suture Techniques , Adult , Corneal Diseases/complications , Ectopia Lentis/complications , Ectopia Lentis/etiology , Female , Glaucoma/complications , Humans , Iris/surgery , Laser Therapy/methods , Lens Capsule, Crystalline/surgery , Lens Implantation, Intraocular/methods , Marfan Syndrome/complications , Middle Aged , Refraction, Ocular/physiology , Sclera/surgery , Visual Acuity/physiology
SELECTION OF CITATIONS
SEARCH DETAIL