Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 7.140
1.
PLoS One ; 19(6): e0305031, 2024.
Article En | MEDLINE | ID: mdl-38843254

Heart rate variability (HRV) is a frequently used indicator of autonomic responses to various stimuli in horses. This study aimed to investigate HRV variables in horses undergoing cold (n = 25) or hot (n = 26) shoeing. Multiple HRV variables were measured and compared between horses undergoing cold and hot shoeing, including the time domain, frequency domain, and nonlinear variables pre-shoeing, during shoeing, and at 30-minute intervals for 120 minutes post-shoeing. The shoeing method interacted with time to change the HRV variables standard deviation of RR intervals (SDNN), root mean square of successive RR interval differences (RMSSD), very-low-frequency band, low-frequency band (LF), the LF to high-frequency band ratio, respiratory rate, total power, standard deviation perpendicular to the line of identity (SD1), and standard deviation along the line of identity (SD2). SDNN, RMSSD, and total power only increased 30 minutes after hot shoeing (all p < 0.05). Triangular interpolation of normal-to-normal intervals (TINN) and the HRV triangular index increased during and up to 120 minutes after hot shoeing (p < 0.05-0.001). TINN increased only during cold shoeing (p < 0.05). LF increased 30 and 60 minutes after hot shoeing (both p < 0.05). SD1 and SD2 also increased 30 minutes after hot shoeing (both p < 0.05). SDNN, TINN, HRV triangular index, LF, total power, and SD2 were higher in hot-shoed than cold-shoed horses throughout the 120 minutes post-shoeing. Differences in HRV were found, indicating increased sympathovagal activity in hot shoed horses compared to cold shoed horses.


Cold Temperature , Heart Rate , Hot Temperature , Animals , Horses/physiology , Heart Rate/physiology , Male , Female , Respiratory Rate/physiology , Shoes
2.
Article En | MEDLINE | ID: mdl-38758669

BACKGROUND: Socks are mainly used to give the foot more comfort while wearing shoes. Stitch density of the knitted fabric used in socks can significantly affect the sock properties because it is one of the most important fabric structural factors influencing the mechanical properties. Continuous plantar pressures can cause serious damage, particularly under the metatarsal heads, and it is deduced that using socks redistributes and reduces peak plantar pressures. If peak pressure under the metatarsal heads is predicted, then it will be possible to produce socks with the best mechanical properties to reduce the pressure in these critical areas. METHODS: Plain knitted socks with three different stitch lengths (high, medium, and low) were produced. Static plantar pressure measurements by the Gaitview system were accomplished on ten women and then compared with the barefoot situation. Also, the peak plantar pressure of three types of socks under the metatarsal heads are theoretically predicted using the Hertz contact theory. RESULTS: Experimental results indicate that all socks redistribute the plantar pressure from high to low plantar pressure regions compared with barefoot. In particular, socks with high stitch length have the best performance. By increasing the stitch length, we can significantly reduce the peak plantar pressure of the socks. Correspondingly, the Hertz contact theory resulted in a trend of mean peak pressure reductions in the forefoot region similar to the socks with different stitch densities. CONCLUSIONS: The theoretical results show that by using the Hertz contact theory, static plantar pressure in the forefoot region can be well predicted at a mean error of approximately 9% compared with the other experimental findings.


Foot , Pressure , Humans , Female , Foot/physiology , Adult , Biomechanical Phenomena , Clothing , Shoes , Weight-Bearing/physiology , Young Adult
3.
PLoS One ; 19(5): e0303826, 2024.
Article En | MEDLINE | ID: mdl-38758937

BACKGROUND: The global number of people with diabetes is estimated to reach 643 million by 2030 of whom 19-34% will present with diabetic foot ulceration. Insoles which offload high-risk ulcerative regions on the foot, by removing insole material, are the main contemporary conservative treatment to maintain mobility and reduce the likelihood of ulceration. However, their effect on the rest of the foot and relationship with key gait propulsive and balance kinematics and kinetics has not been well researched. PURPOSE: The aim of this study is to investigate the effect of offloading insoles on gait kinematics, kinetics, and plantar pressure throughout the gait cycle. METHODS: 10 healthy subjects were recruited for this experiment to walk in 6 different insole conditions. Subjects walked at three speeds on a treadmill for 10 minutes while both plantar pressure and gait kinematics, kinetics were measured using an in-shoe pressure measurement insole and motion capture system/force plates. Average peak plantar pressure, pressure time integrals, gait kinematics and centre of force were analysed. RESULTS: The average peak plantar pressure and pressure time integrals changed by -30% (-68% to 3%) and -36% (-75% to -1%) at the region of interest when applying offloading insoles, whereas the heel strike and toe-off velocity changed by 15% (-6% to 32%) and 12% (-2% to 19%) whilst walking at three speeds. CONCLUSION: The study found that offloading insoles reduced plantar pressure in the region of interest with loading transferred to surrounding regions increasing the risk of higher pressure time integrals in these locations. Heel strike and toe-off velocities were increased under certain configurations of offloading insoles which may explain the higher plantar pressures and supporting the potential of integrating kinematic gait variables within a more optimal therapeutic approach. However, there was inter-individual variability in responses for all variables measured supporting individualised prescription.


Calcaneus , Foot Orthoses , Gait , Pressure , Humans , Gait/physiology , Biomechanical Phenomena , Pilot Projects , Male , Female , Adult , Calcaneus/physiology , Healthy Volunteers , Shoes , Kinetics , Walking/physiology , Metatarsus/physiology , Foot/physiology
4.
Dermatol Online J ; 30(1)2024 Mar 15.
Article En | MEDLINE | ID: mdl-38762854

Retronychia is commonly underdiagnosed and exhibits classic features of proximal nail fold elevation and nail plate layering. Herein we summarize the literature and discuss cause, diagnosis, and treatment of this condition.


Shoes , Humans , Nails/pathology , Nails, Ingrown/therapy , Nail Diseases/diagnosis , Nail Diseases/pathology
5.
J Foot Ankle Res ; 17(2): e12019, 2024 Jun.
Article En | MEDLINE | ID: mdl-38812247

BACKGROUND: Little is known about factors that influence footwear selection by field hockey players. METHODS: An online survey was used to collect data on participant demographics and physical characteristics, factors influencing footwear selection, perceptions regarding footwear design features on injury and performance, and experiences regarding usability. Nominal and ordinal data were described as absolute frequencies and relative frequencies. Free text responses were analysed using content analysis. Sex-related differences in quantitative and qualitative data were explored. RESULTS: A total of 401 hockey players completed the survey. Participants reported that fit, comfort, support, and cushioning were the most important factors when selecting hockey footwear. Most hockey players believed that stud design could influence athletic performance (65%) and injury risk (63%) but reported having no preference on outsole design or stud shape. Most participants (63%) used hockey-specific footwear, but 46% of female hockey players did not, with 40% using trail running footwear instead. Qualitative analysis revealed that hockey players, particularly female participants, encounter difficulties finding properly fitting footwear. They desire more options for wide or narrow feet and face challenges in accessing suitable hockey shoes due to limited choices and availability. CONCLUSIONS: With over a third of field hockey players not using hockey-specific footwear, future research should attempt to understand the reasons and assess the impact of different footwear features on comfort, performance, injury risk, and usability.


Hockey , Shoes , Humans , Female , Male , Adult , Young Adult , Surveys and Questionnaires , Adolescent , Equipment Design , Athletic Performance/physiology , Sex Factors , Athletic Injuries/prevention & control , Middle Aged
6.
Sensors (Basel) ; 24(9)2024 May 06.
Article En | MEDLINE | ID: mdl-38733050

Gait phase monitoring wearable sensors play a crucial role in assessing both health and athletic performance, offering valuable insights into an individual's gait pattern. In this study, we introduced a simple and cost-effective capacitive gait sensor manufacturing approach, utilizing a micropatterned polydimethylsiloxane dielectric layer placed between screen-printed silver electrodes. The sensor demonstrated inherent stretchability and durability, even when the electrode was bent at a 45-degree angle, it maintained an electrode resistance of approximately 3 Ω. This feature is particularly advantageous for gait monitoring applications. Furthermore, the fabricated flexible capacitive pressure sensor exhibited higher sensitivity and linearity at both low and high pressure and displayed very good stability. Notably, the sensors demonstrated rapid response and recovery times for both under low and high pressure. To further explore the capabilities of these new sensors, they were successfully tested as insole-type pressure sensors for real-time gait signal monitoring. The sensors displayed a well-balanced combination of sensitivity and response time, making them well-suited for gait analysis. Beyond gait analysis, the proposed sensor holds the potential for a wide range of applications within biomedical, sports, and commercial systems where soft and conformable sensors are preferred.


Gait , Pressure , Wearable Electronic Devices , Wireless Technology , Humans , Gait/physiology , Wireless Technology/instrumentation , Gait Analysis/methods , Gait Analysis/instrumentation , Electrodes , Shoes , Equipment Design
7.
Sci Justice ; 64(3): 264-268, 2024 May.
Article En | MEDLINE | ID: mdl-38735661

In forensic podiatry, footprints have been shown to provide a valuable source of discriminatory information. Footprints may be found in various forms, such as bare footprints, sock-clad footprints, or as impressions on insoles within footwear. This study utilized quantitative measures of foot impressions on pairs of insoles from shoes worn by the same person from a population of 31 adults. The measurements were determined by using the Reel method and comprised measurements from the heel to the tips of the toes and width of the ball. The purpose of the study was to assess the margin of error for these measurements to determine whether they were sufficiently accurate for forensic use. A secondary purpose of this study was to determine whether the analyst's experience or lack thereof in forensic podiatry had an impact on the precision of measurement data. The insole foot impressions were assessed by two podiatrists with forensic podiatry experience in footprint analysis, footprint research, and in using the Reel method of footprint measurement, as well as by three students of podiatric medicine without any such experience. A statistical analysis of the data from the study was performed using SPSS v28 (IBM SPSS Statistics for Windows, Version 28.0. Armonk, NY: IBM Corp). The most reliable measurements were of forefoot width, heel to first toe, heel to second toe, and heel to fourth toe. The greatest variation occurred in the measurements of the heel to the third and fifth toes. The measurements of the forensic podiatrist analysts showed less variability than those of the podiatry students, suggesting that measurement precision is related to the experience of the analyst.


Foot , Shoes , Humans , Foot/anatomy & histology , Adult , Male , Female , Forensic Sciences/methods , Podiatry , Middle Aged , Young Adult
8.
Sci Rep ; 14(1): 11903, 2024 05 24.
Article En | MEDLINE | ID: mdl-38789519

Technologically advanced running shoes (TARS) improve performance compared to classical running shoes (CRS). Improved race performance has been attributed to metabolic savings in male runners, but it remains unclear if these same benefits are experienced among females and in recreational runners. The mechanisms behind these benefits are still not fully understood despite the need for optimisation, and their influence on injury mechanisms has not been explored. Here we combined biomechanical, physiological, and modelling approaches to analyse joint mechanics, oxygen uptake, and tibial load in nineteen male and female recreational runners running with CRS and TARS at their individual lactate threshold speed (12.4 ± 1.9 km/h). Oxygen uptake was 3.0 ± 1.5% lower in TARS than in CRS. Ankle dorsiflexion, joint moment and joint power were reduced in TARS compared to CRS at various phases of stance including midstance, while knee joint mechanics were mostly similar throughout. There were no significant differences for tibial bending moment during the stance phase but cumulative tibial damage per kilometre was 12 ± 9% lower in TARS compared to CRS. Our results suggest that running with TARS reduces oxygen cost in recreational female and male runners, which may partly be explained by differences in lower limb joint mechanics. The lower cumulative tibial bone load with TARS may allow runners to run longer distances in this type of shoe compared to CRS.


Oxygen Consumption , Running , Shoes , Tibia , Humans , Running/physiology , Male , Female , Adult , Biomechanical Phenomena , Tibia/physiology , Oxygen Consumption/physiology , Young Adult , Knee Joint/physiology , Oxygen/metabolism
9.
J Biomech ; 169: 112138, 2024 May.
Article En | MEDLINE | ID: mdl-38728788

The shoe sole is identified as a fall risk factor since it may impede the afferent information about the outside world collected by the plantar sensory units. However, no study has directly quantified how the shoe sole compromises body balance and increases fall risk. This study aimed to inspect how the sole affects human balance after an unexpected standing-slip. It was hypothesized that individuals wearing the sole, relative to their barefoot counterparts, would exhibit 1) more impaired stability and 2) disrupted lower limb muscle activation following a standing-slip. Twenty young adults were evenly randomized into two groups: soled and barefoot. The soled group wore a pair of customized 10-mm thick soles, while the other group was bare-footed. Full-body kinematics and leg muscle electromyography (EMG) were collected during a standardized and unexpected standing-slip. The EMG electrodes were placed on the tibialis anterior, gastrocnemius, rectus femoris, and biceps femoris bilaterally. Dynamic stability, spatiotemporal gait parameters, and the EMG latency of the leg muscles were compared between groups. The sole impeded the initiation of the recovery step possibly because it interfered with the accurate detection of the external perturbation and subsequently activated the leg muscles later in the soled group than in the barefoot group. As a result, individuals in the soled group experienced a longer slip distance and were more unstable than the barefoot group at the recovery foot liftoff. The findings of this study could augment our understanding of how the shoe sole impairs body balance and increases the fall risk.


Accidental Falls , Electromyography , Muscle, Skeletal , Postural Balance , Shoes , Humans , Postural Balance/physiology , Male , Muscle, Skeletal/physiology , Female , Young Adult , Accidental Falls/prevention & control , Adult , Leg/physiology , Gait/physiology , Biomechanical Phenomena
10.
Gait Posture ; 111: 156-161, 2024 Jun.
Article En | MEDLINE | ID: mdl-38703444

BACKGROUND: Hallux valgus is a common condition where the subluxation of the first metatarsophalangeal joint and lateral deviation of the hallux at the interphalangeal joint creates difficulty with footwear fit. Footwear and foot orthoses are commonly prescribed nonsurgical treatments for hallux valgus. RESEARCH QUESTION: Do extra-width footwear and foot orthoses influence peak pressure at the medial aspect of the metatarsophalangeal and interphalangeal joints in women with hallux valgus? METHODS: Community-dwelling women with symptomatic hallux valgus underwent gait testing when wearing their own shoes and when wearing extra-width footwear fitted with three-quarter length, arch-contouring prefabricated foot orthoses. Peak pressure (kPa) on the medial aspect of the metatarsophalangeal and medial interphalangeal joints and on the plantar surface of the foot (hallux, lesser toes, metatarsophalangeal joint 1, metatarsophalangeal joints 2-5, midfoot and heel) were measured using the novel pedar®-X system with the pedar® pad and pedar® insole, respectively (Novel, GmbH, Munich, Germany). Paired samples t-tests were used to calculate the differences between the two conditions, and the magnitude of observed differences was calculated using Cohen's d. RESULTS: We tested 28 participants (aged 44-80 years, mean 60.7, standard deviation 10.7). Compared to their own footwear, wearing the intervention footwear and orthoses was associated with a statistically significant decrease in pressure on the medial aspect of the metatarsophalangeal joint (58.3 ± 32.8 versus 42.6 ± 32.8, p=0.026, d=0.49), increased pressure under the midfoot (70.7 ± 25.7 versus 78.7 ± 23.6, p=0.029, d=0.33) and decreased pressure underneath the heel (137.3 ± 39.0 versus 121.3 ± 34.8, p=0.019, d=0.45). SIGNIFICANCE: The intervention footwear and orthoses significantly decreased peak pressure on the medial aspect of the first metatarsophalangeal joint but had no significant effect on the interphalangeal joint. Further studies are required to determine whether these changes are associated with improvements in symptoms associated with hallux valgus.


Foot Orthoses , Hallux Valgus , Metatarsophalangeal Joint , Pressure , Shoes , Humans , Female , Metatarsophalangeal Joint/physiopathology , Middle Aged , Hallux Valgus/rehabilitation , Hallux Valgus/physiopathology , Hallux Valgus/therapy , Aged , Adult
11.
Gait Posture ; 111: 162-168, 2024 Jun.
Article En | MEDLINE | ID: mdl-38703445

BACKGROUND: People with plantar flexor weakness generate less ankle push-off work during walking, resulting in inefficient proximal joint compensations. To increase push-off work, spring-like ankle foot orthoses (AFOs) can be provided. However, whether and in which patients AFOs increase push-off work and reduce compensatory hip and knee work is unknown. METHODS: In 18 people with bilateral plantar flexor weakness, we performed a 3D gait analysis at comfortable walking speed with shoes-only and with AFOs of which the stiffness was optimized. To account for walking speed differences between conditions, we compared relative joint work of the hip, knee and ankle joint. The relationships between relative work generated with shoes-only and changes in joint work with AFO were tested with Pearson correlations. RESULTS: No differences in relative ankle, knee and hip work over the gait cycle were found between shoes-only and AFO (p>0.499). Percentage of total ankle work generated during pre-swing increased with the AFO (AFO: 85.3±9.1% vs Shoes: 72.4±27.1%, p=0.026). At the hip, the AFO reduced relative work in pre-swing (AFO: 31.9±7.4% vs Shoes: 34.1±10.4%, p=0.038) and increased in loading response (AFO: 18.0±11.0% vs Shoes: 11.9±9.8%, p=0.022). Ankle work with shoes-only was inversely correlated with an increase in ankle work with AFO (r=-0.839, p<0.001) and this increase correlated with reduction in hip work with AFO (r=-0.650, p=0.004). DISCUSSION: Although stiffness-optimized AFOs did not alter the work distribution across the ankle, knee and hip joint compared to shoes-only walking, relative more ankle work was generated during push-off, causing a shift in hip work from pre-swing to loading response. Furthermore, larger ankle push-off deficits when walking with shoes-only were related with an increase in ankle work with AFO and reduction in compensatory hip work, indicating that more severely affected individuals benefit more from the energy storing-and-releasing capacity of AFOs.


Ankle Joint , Foot Orthoses , Humans , Male , Female , Ankle Joint/physiopathology , Middle Aged , Adult , Biomechanical Phenomena , Hip Joint/physiopathology , Gait Analysis , Knee Joint/physiopathology , Neuromuscular Diseases/rehabilitation , Neuromuscular Diseases/physiopathology , Gait/physiology , Shoes , Aged , Gait Disorders, Neurologic/rehabilitation , Gait Disorders, Neurologic/etiology , Gait Disorders, Neurologic/physiopathology
12.
Technol Health Care ; 32(S1): 487-499, 2024.
Article En | MEDLINE | ID: mdl-38759071

BACKGROUND: Shoes upper has been shown to affect the shoe microclimate (temperature and humidity). However, the existing data on the correlation between the microclimate inside footwear and the body's physical factors is still quite limited. OBJECTIVE: This study examined whether shoes air permeability would influence foot microclimate and spatial characteristics of lower limb and body. METHODS: Twelve recreational male habitual runners were instructed to finish an 80 min experimental protocol, wearing two running shoes with different air permeability. RESULTS: Participants wearing CLOSED upper structure shoe exhibited higher in-shoe temperature and relative humidity. Although there was no significant difference, shank temperature and metabolism in OPEN upper structure shoes were lower. CONCLUSIONS: This indicates that the air permeability of shoes can modify the microclimate of the feet, potentially affecting the lower limb temperature. This study provides relevant information for the design and evaluation of footwear.


Humidity , Microclimate , Running , Shoes , Humans , Male , Running/physiology , Adult , Young Adult , Temperature , Foot/physiology , Body Temperature/physiology , Equipment Design
13.
Sensors (Basel) ; 24(10)2024 May 15.
Article En | MEDLINE | ID: mdl-38793985

Sensory peripheral neuropathy is a common complication of diabetes mellitus and the biggest risk factor for diabetic foot ulcers. There is currently no available treatment that can reverse sensory loss in the diabetic population. The application of mechanical noise has been shown to improve vibration perception threshold or plantar sensation (through stochastic resonance) in the short term, but the therapeutic use, and longer-term effects have not been explored. In this study, vibrating insoles were therapeutically used by 22 participants, for 30 min per day, on a daily basis, for a month by persons with diabetic sensory peripheral neuropathy. The therapeutic application of vibrating insoles in this cohort significantly improved VPT by an average of 8.5 V (p = 0.001) post-intervention and 8.2 V (p < 0.001) post-washout. This statistically and clinically relevant improvement can play a role in protection against diabetic foot ulcers and the delay of subsequent lower-extremity amputation.


Diabetes Mellitus, Type 2 , Diabetic Foot , Vibration , Humans , Pilot Projects , Vibration/therapeutic use , Male , Diabetes Mellitus, Type 2/complications , Diabetes Mellitus, Type 2/therapy , Female , Middle Aged , Diabetic Foot/therapy , Aged , Diabetic Neuropathies/therapy , Diabetic Neuropathies/physiopathology , Foot/physiopathology , Peripheral Nervous System Diseases/therapy , Peripheral Nervous System Diseases/physiopathology , Shoes , Sensation/physiology , Foot Orthoses
14.
Sensors (Basel) ; 24(10)2024 May 17.
Article En | MEDLINE | ID: mdl-38794059

Assessing mobility in daily life can provide significant insights into several clinical conditions, such as Chronic Obstructive Pulmonary Disease (COPD). In this paper, we present a comprehensive analysis of wearable devices' performance in gait speed estimation and explore optimal device combinations for everyday use. Using data collected from smartphones, smartwatches, and smart shoes, we evaluated the individual capabilities of each device and explored their synergistic effects when combined, thereby accommodating the preferences and possibilities of individuals for wearing different types of devices. Our study involved 20 healthy subjects performing a modified Six-Minute Walking Test (6MWT) under various conditions. The results revealed only little performance differences among devices, with the combination of smartwatches and smart shoes exhibiting superior estimation accuracy. Particularly, smartwatches captured additional health-related information and demonstrated enhanced accuracy when paired with other devices. Surprisingly, wearing all devices concurrently did not yield optimal results, suggesting a potential redundancy in feature extraction. Feature importance analysis highlighted key variables contributing to gait speed estimation, providing valuable insights for model refinement.


Walking Speed , Wearable Electronic Devices , Humans , Walking Speed/physiology , Male , Female , Adult , Smartphone , Shoes , Gait/physiology , Walking/physiology , Young Adult
15.
Sci Rep ; 14(1): 9291, 2024 04 23.
Article En | MEDLINE | ID: mdl-38654097

In the dynamic world of fashion, high-heeled footwear is revered as a symbol of style, luxury and sophistication. Yet, beneath the facade of elegance of classy footwear lies the harsh reality of discomfort and pain. Thus, this study aims to investigate the influence of wearing high-heeled shoes on the sensation of pain across different body regions over a period of 6 h. It involved fifty female participants, all habitual wearers of high-heeled shoes, aged between 20 and 30 years. Each participant kept a record of their perceptions of pain and discomfort every hour for a total of 6 h using a 0-10 pain scale with 0 indicating no pain and 10 indicating severe pain. The findings reveal a progressive rise in pain throughout wear, with the most intense pain reported in the back, calcaneus, and metatarsals. The analysis shows that after approximately 3.5 h, participants experience significant increases in pain levels. However, the relationship between heel height and pain is not linear. It appears that a heel height of 7.5 cm is the threshold where overall body pain becomes significant. The study suggests that a duration of 3.5 h of wear and a heel height of 7.5 cm serve as critical points to decrease overall body pain. Moreover, beyond this heel height, knee pain diminishes compared to other body areas possibly due to the shift towards a more neutral posture. The study findings, coupled with the recommendations, can assist footwear designers in crafting not only stylish but also comfortable shoes.


Pain , Shoes , Humans , Shoes/adverse effects , Female , Adult , Pain/etiology , Young Adult , Pain Measurement , Heel
17.
J Wound Care ; 33(4): 220-228, 2024 Apr 02.
Article En | MEDLINE | ID: mdl-38573905

OBJECTIVE: To evaluate the clinical performance, quality of life (QoL) and patient satisfaction with an innovative flat-knit compression garment for the daytime treatment of lymphoedema patients in daily routine. METHOD: In a prospective multicentre observational study, patients with leg or arm lymphoedema (stage I-II, International Society of Lymphology (ISL) standards, 2016) received a made-to-measure flat-knit compression class 2 JOBST Confidence (BSN-JOBST GmbH, Germany) thigh-high stocking or arm sleeve. Primary endpoint was the oedema status as determined by the mean sum of the circumferences at the beginning and the end of the wearing period. Secondary endpoints included QoL-related parameters and patient satisfaction with product features assessed through questionnaires. The observation period lasted three weeks. RESULTS: A total of 97 patients (87 females, 10 males), of which 65 had leg lymphoedema and 32 had arm lymphoedema, received the study device. The oedema status was effectively maintained (slight reduction in mean sum of circumferences by -3.1±7.3cm; p=0.0001). For QoL-related parameters, the patients reported fewer limitations in work, leisure and psychological wellbeing after wearing the stocking or arm sleeve (all p-values <0.0001). They also experienced less limitations in function and movement, feeling of tension and heaviness, and fewer difficulties wearing clothes, shoes, jewellery or watches at study end (all p-values <0.0001). In terms of pleasant feeling on the skin, moisture management, softness of material, range of motion, overall wearing comfort and heat build-up under the garment, patients were more satisfied with the tested compression garment than with previously worn compression garments (all p-values <0.001). CONCLUSION: In this study, the tested innovative compression product increased patient satisfaction with the improved product features while the lymphoedema status was successfully maintained.


Lymphedema , Quality of Life , Male , Female , Humans , Prospective Studies , Lymphedema/therapy , Lymphedema/psychology , Compression Bandages , Edema/therapy , Shoes
18.
J Biomech ; 166: 112063, 2024 Mar.
Article En | MEDLINE | ID: mdl-38564846

Force-sensing insoles are wearable technology that offer an innovative way to measure loading outside of laboratory settings. Few studies, however, have utilized insoles to measure daily loading in real-world settings. This is an ancillary study of a randomized controlled trial examining the effect of weight loss alone, weight loss plus weighted vest, or weight loss plus resistance training on bone health in older adults. The purpose of this ancillary study was to determine the feasibility of using force-sensing insoles to collect daily limb loading metrics, including peak force, impulse, and loading rate. Forty-four participants completed a baseline visit of three, 2-minute walking trials while wearing force-sensing insoles. During month two of the intervention, 37 participants wore insoles for 4 days for 8 waking hours each day. At 6-month follow-up, participants completed three, two-minute walking trials and a satisfaction questionnaire. Criteria for success in feasibility was defined as: a) > 60 % recruitment rate; b) > 80 % adherence rate; c) > 75 % of usable data, and d) > 75 % participant satisfaction. A 77.3 % recruitment rate was achieved, with 44 participants enrolled. Participants wore their insoles an average of 7.4 hours per day, and insoles recorded an average of 5.5 hours per day. Peak force, impulse, and loading rate collected at baseline and follow-up were 100 % usable. During the real-world settings, 87.8 % of data was deemed usable with an average of 1200 min/participant. Lastly, average satisfaction was 80.5 %. These results suggest that force-sensing insoles appears to be feasible to capture real-world limb loading in older adults.


Mechanical Phenomena , Walking , Humans , Aged , Feasibility Studies , Extremities , Weight Loss , Shoes
19.
Scand J Med Sci Sports ; 34(4): e14630, 2024 Apr.
Article En | MEDLINE | ID: mdl-38644663

The effects of a 12-week gait retraining program on the adaptation of the medial gastrocnemius (MG) and muscle-tendon unit (MTU) were investigated. 26 runners with a rearfoot strike pattern (RFS) were randomly assigned to one of two groups: gait retraining (GR) or control group (CON). MG ultrasound images, marker positions, and ground reaction forces (GRF) were collected twice during 9 km/h of treadmill running before and after the intervention. Ankle kinetics and the MG and MTU behavior and dynamics were quantified. Runners in the GR performed gradual 12-week gait retraining transitioning to a forefoot strike pattern. After 12-week, (1) ten participants in each group completed the training; eight participants in GR transitioned to non-RFS with reduced foot strike angles; (2) MG fascicle contraction length and velocity significantly decreased after the intervention for both groups, whereas MG forces increased after intervention for both groups; (3) significant increases in MTU stretching length for GR and peak MTU recoiling velocity for both groups were observed after the intervention, respectively; (4) no significant difference was found for all parameters of the series elastic element. Gait retraining might potentially influence the MG to operate at lower fascicle contraction lengths and velocities and produce greater peak forces. The gait retraining had no effect on SEE behavior and dynamics but did impact MTU, suggesting that the training was insufficient to induce mechanical loading changes on SEE behavior and dynamics.


Gait , Muscle, Skeletal , Running , Shoes , Tendons , Humans , Running/physiology , Muscle, Skeletal/physiology , Gait/physiology , Male , Biomechanical Phenomena , Adult , Tendons/physiology , Young Adult , Female , Ultrasonography , Adaptation, Physiological
20.
Gait Posture ; 111: 8-13, 2024 Jun.
Article En | MEDLINE | ID: mdl-38603968

BACKGROUND: Peripheral neuropathy is one of the most common complications of type 2 diabetes, which can lead to impaired balance and walking. Innovative footwear devices designed to stimulate foot sensory receptors, such as vibrating insoles, could offer a new route to improve motor impairments in people with diabetic peripheral neuropathy (DPN). RESEARCH QUESTION: Does wearing vibrating insoles for the first time alter measures of balance, walking, and ankle-foot muscle activity, in people with DPN? METHODS: A randomised cross-over study was conducted with 18 ambulant men and women with a diagnosis of DPN. Participants performed tests of standing balance (Bertec® force platform) under four conditions (foam/firm surface, eyes open/closed) and level-ground walking (GAITRite® instrumented walkway), whilst wearing vibrating and non-vibrating (control) insoles on two separate occasions (one insole/session). Electromyography (EMG) was used to assess soleus, medial gastrocnemius, tibialis anterior, peroneus longus activity during balance tests. Outcomes included centre of pressure (CoP) sway, EMG amplitude, spatiotemporal gait patterns, and Timed Up and Go test. One sample t-tests were used to explore %differences in outcomes between insole conditions. RESULTS: Wearing vibrating insoles led to a reduction (improvement) in CoP elliptical area, when standing on a foam surface with eyes closed, relative to non-vibrating insoles (P=0.03). Applying perceptible vibrations to the soles of the feet also reduced the EMG amplitude in soleus (P=0.01 and P=0.04) and medial gastrocnemius (P=0.03 and P=0.09) when standing with eyes closed on firm and foam surfaces. SIGNIFICANCE: Our findings of signs of improved balance and altered muscle activity with suprasensory vibrating insoles provides new insights into how these devices can be used to inform innovative rehabilitation approaches in individuals with DPN. This will be strengthened by further research into possible clinical benefits of these devices - given that the effects we detected were small with uncertain clinical meaning.


Cross-Over Studies , Diabetic Neuropathies , Electromyography , Foot Orthoses , Muscle, Skeletal , Postural Balance , Shoes , Vibration , Walking , Humans , Postural Balance/physiology , Male , Female , Vibration/therapeutic use , Diabetic Neuropathies/physiopathology , Diabetic Neuropathies/rehabilitation , Middle Aged , Walking/physiology , Muscle, Skeletal/physiopathology , Aged , Foot/physiopathology , Ankle/physiopathology
...