Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.800
Filter
1.
Respir Investig ; 62(4): 732-737, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38878626

ABSTRACT

BACKGROUND: Cryobiopsy use is anticipated to become more common in diagnosing lung diseases. In Japan, inserting a Fogarty catheter through a suction channel above the endotracheal tube's cuff for hemostasis is common practice. However, the rigid nature of the endotracheal tube poses challenges to tracheal intubation using a bronchoscope. The endotracheal tube cuff must be removed to prevent interference during Fogarty catheter insertion. To simplify the procedure and enhance safety, we devised and implemented a method of inserting a hemostatic Fogarty catheter with a suction tube externally attached to a softer endotracheal tube. This study aimed to evaluate the sustainability of this Fogarty catheter insertion method using suction tubes. METHODS: The hemostatic Fogarty catheter insertion method was retrospectively validated. We compared outcomes between 60 patients who underwent the conventional method with a suction channel above the cuff and 50 patients who underwent the novel approach with an externally attached suction tube. RESULTS: The physicians performing bronchoscopy and inserting the Fogarty catheter in the group in which the suction tube was externally attached for Fogarty catheter insertion had little experience. However, the overall bronchoscopy time was shorter; the two groups showed no significant differences in complications. CONCLUSION: Regarding cryobiopsy procedures, using an externally attached suction tube for Fogarty catheter insertion was practical and comparable to the conventional method of using a suction channel above the cuff. This method made the procedure more simple and safe.


Subject(s)
Bronchoscopy , Intubation, Intratracheal , Humans , Retrospective Studies , Intubation, Intratracheal/instrumentation , Intubation, Intratracheal/methods , Suction/instrumentation , Suction/methods , Bronchoscopy/methods , Male , Female , Aged , Biopsy/methods , Biopsy/instrumentation , Middle Aged , Catheters , Cryosurgery/methods , Cryosurgery/instrumentation
2.
Pediatr Dent ; 46(3): 199-203, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38822496

ABSTRACT

Purpose: The purposes of this in vitro study were to evaluate the effect of three isolation methods to mitigate bioaerosols during stainless steel crown (SSC) preparations and assess the distribution of Streptococcus mutans by aerosolization in closed-room operatories. Methods: Melamine teeth coated in laboratory-grown S. mutans biofilm were prepared for SSCs using three different isolation methods. Agar plates were placed in five locations throughout the operatory and opened during each preparation as well as for 10 minutes immediately following to collect aerosolized S. mutans. Bacterial colonies were counted after incubating plates for 48 hours. Data were analyzed for differences between the isolation method and plate locations. Results: Bacterial colony counts for teeth prepared using high-volume evacuation suction (HVE) with dental dam (DD) isolation were statistically significantly higher than for those prepared using HVE with a DryShield®(DS) and HVE with no isolation at the assistant (A) (P<0.001), operator face shield (FS) (P<0.001), and patient (Pt) (P=0.002) locations. No significant differences were found among isolation methods for parent (Pa) or rear delivery (RD) locations. The location that produced the most bacterial colony counts using HVE with DD isolation was FS (P<0.001), followed by A (P=0.04), Pt (P<0.001), and RD and Pa (P<0.001). Counts produced from teeth prepared with DS isolation were significantly higher at the Pt location than the A (P<0.001), FS (P=0.002), RD (P<0.001), and Pa (P=0.008) locations. Conclusion: The use of dental dam with high-volume evacuation suction during stainless steel crown preparations increased bioaerosols near the procedure, while dental evacuation systems (DryShield®) may effectively limit their spread.


Subject(s)
Aerosols , Streptococcus mutans , Humans , Streptococcus mutans/isolation & purification , Stainless Steel , Crowns , In Vitro Techniques , Air Microbiology , Colony Count, Microbial , Biofilms , Bacterial Load , Suction/instrumentation , Infection Control, Dental/methods
3.
Ren Fail ; 46(2): 2369695, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38938162

ABSTRACT

BACKGROUND: This study aims to establish a simplified and effective animal model of catheter malfunction caused by omental wrapped using negative pressure suction. METHOD: The peritoneal dialysis catheter outlet was linked to a negative-pressure (0-75mmHg) suction pump to intensify the negative pressure. Different negative pressures were tested for model construction in vitro. In vivo, a model of peritoneal catheter malfunction caused by omental wrapped was constructed in five beagles after catheter placement. Catheter drainage conditions and related complications were monitored before and after the model establishment. RESULTS: In the vitro experiment, the overall success rate of constructed models was 90% (36/40). The total malfunction rate was higher in 62.5 mmHg (10/10) and 75 mmHg (10/10) than in 12.5 mmHg (8/10) and 37.5 mmHg (8/10). The outflow velocity of dialysate at 62.5 mmHg was significantly lower than that at 12.5 mmHg and 37.5 mmHg, without a statistically significant difference compared to 75 mmHg. In the in vivo experiment, catheter outflow velocity increased, and residual fluid volume decreased after omental wrapped (99.6 ± 6.7 ml/min vs. 32.6 ± 4.6 ml/min at initial five minutes, p < 0.0001; 69.2 ± 16.3 ml vs. 581.0 ± 109.4 ml, p < 0.001). And the outflow velocity was finally below 2 ml/min. No severe related complications (such as infection, organ damage, or bleeding) were observed through laparoscopic examination and dialysate tests seven days post-operation. CONCLUSION: Utilizing negative pressure suction to increase negative pressure around catheter tip is a simple, safe, and effective method for establishing an animal model of omental wrapped leading to catheter malfunction.


Subject(s)
Equipment Failure , Omentum , Peritoneal Dialysis , Animals , Dogs , Suction/instrumentation , Peritoneal Dialysis/instrumentation , Peritoneal Dialysis/adverse effects , Catheters, Indwelling/adverse effects , Disease Models, Animal , Male , Models, Animal
4.
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue ; 36(4): 422-424, 2024 Apr.
Article in Chinese | MEDLINE | ID: mdl-38813639

ABSTRACT

Sputum suction is a necessary measure to remove respiratory secretions and collect sputum specimens, and the traditional sputum suction device includes open and closed methods. However, the open sputum suction device can easily cause sputum splashing during operation, polluting the operator and the surrounding environment. The closed sputum suction device is more expensive than the open sputum suction device. Although it can be used repeatedly, the friction between the protective sleeve and the wall of the suction tube increases after repeated uses, which in turn affects the operation. In addition, the two sputum suction methods need to be connected to a sputum collector when the sputum specimen is collected. This process can easily lead to leakage and contamination of specimens, and at the same time increase the infection risk for patients. In order to overcome the above problems, the medical staff from the department of critical care medicine of the First Affiliated Hospital of Dalian Medical University invented a new type of switchable semi-closed sputum suction device, and obtained the National Utility Model Patent of China (ZL 2020 2 1564712.3). The device is composed of a suction device connection port, a sliding negative pressure switch, an adapter interface, a pipe body, a transparent film protective sleeve, a clip-on connection joint, and a sputum collector. The sliding negative pressure switch at the connection port of the suction device can realize one-person one-handed operation. The sputum collector is connected with the sputum suction device to ensure that the specimen is not exposed. The transparent film protective sleeve covers the sputum suction tube body to ensure that the whole process of sputum suction operation is pollution-free. The clip-on connection joint is connected with the artificial airway interface to avoid sputum splashing during sputum suction, and it is clamped immediately after operation to reduce environmental pollution. Compared with the existing sputum suction device, the new switchable semi-closed sputum suction device has a more reasonable design and lower cost, which is worthy of clinical promotion.


Subject(s)
Equipment Design , Sputum , Suction/instrumentation , Humans
5.
Surg Infect (Larchmt) ; 25(5): 384-391, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38752928

ABSTRACT

Background: No in vitro surgical study has evaluated the time-dependent contamination of surgical suction tips compared with controls. Our purpose was to determine the difference in suction tip bacterial contamination rates between suction-positive and suction-negative tips. Materials and Methods: A matched-pair analysis of the contamination of surgical suction tips over a six-hour period was performed in two clean operating rooms. One suction tip was connected to standard wall suction (suction-positive group), with a matched control tip not connected to wall suction (suction-negative group). At time zero and then at hourly intervals for six hours, the distal 3 cm of suction tips were removed, placed in nutrient broth for 48 hours, then plate cultured. One hundred tips were collected for each time interval. Results: Eighty-two of 700 (11.7%) suction tips had bacterial contamination. Sixty-three (18.0%) of 350 suction-positive tips were contaminated, with 19 (5.4%) of the 350 suction-negative tips contaminated (χ2 = 26.7, p < 0.001). Suction tip contamination was time-dependent with the first significant difference between groups occurring after two hours of continuous suction (χ2 = 4.0, p = 0.04). Contamination rate in the suction-positive group increased significantly after one hour compared with time-zero controls (χ2 = 7.1, p = 0.008). There was no significant difference in frequency of positive cultures over time in the suction-negative group compared with time-zero controls. Conclusions: This is the first controlled laboratory study suggesting a time-dependent increase in positive suction tip cultures. From our data, operating room staff should have an awareness that suction tips represent a potential source of bacterial concentration. We recommend that when not in use, suction tip valves be closed if this feature is available, that hosing be manipulated to cease suction when not needed, that suckers be disconnected from tubing, or that suckers be exchanged at frequent intervals. Doing so may reduce bacterial contamination on the suction tip.


Subject(s)
Bacteria , Equipment Contamination , Operating Rooms , Suction/instrumentation , Bacteria/isolation & purification , Bacteria/classification , Time Factors , Humans , Surgical Instruments/microbiology
8.
Actas urol. esp ; 48(1): 57-70, Ene-Febr. 2024. graf, tab
Article in English, Spanish | IBECS | ID: ibc-229107

ABSTRACT

Objetivo Identificar los últimos avances en los dispositivos de aspiración para la cirugía retrógrada intrarrenal (CRIR) y la ureteroscopia en el tratamiento de la litiasis, y evaluar los resultados de su aplicación. Procedimiento El 4 de enero de 2023 se realizó una búsqueda bibliográfica sistemática en Scopus, PubMed y EMBASE. Solo se incluyeron artículos en inglés; se aceptaron estudios en la población pediátrica y estudios en adultos. Se excluyeron los estudios duplicados, los informes de casos, las cartas al editor y los resúmenes de congresos. Hallazgos principales Se seleccionaron 21 trabajos. Se han propuesto varios sistemas de aspiración para la CRIR: a través de la vaina de acceso ureteral o directamente por el endoscopio. La inteligencia artificial también puede desempeñar un papel, monitorizando los valores de la presión y del flujo de irrigación. Todas las técnicas propuestas mostraron resultados perioperatorios satisfactorios en cuanto a tiempo quirúrgico, tasa libre de cálculos (TLC) y fragmentos residuales. Además, la reducción de la presión intrarrenal (mediante la aspiración) también se asoció a una tasa de infección menor. Incluso los estudios que incluyen cálculos renales con un diámetro de 20mm o superior informan de una mayor TLC y una reducción de las complicaciones postoperatorias. Sin embargo, la falta de parámetros bien establecidos para la presión de la aspiración y el flujo de líquido impide la estandarización del procedimiento. Conclusión Como ha sido demostrado en los estudios incluidos, el uso de dispositivos de aspiración en el tratamiento quirúrgico de los cálculos urinarios favorece la obtención de una TLC mayor y reduce las complicaciones infecciosas. La CRIR con sistema de aspiración podría sustituir a la técnica tradicional, gracias a sus ventajas asociadas al control de la presión intrarrenal y aspiración del polvo fino. (AU)


Objective To identify the latest advances in suction devices and evaluate their effect in Retrograde intrarenal surgery (RIRS) and ureteroscopy for stones. Basic procedures A systematic literature search was performed on 4th January 2023 using Scopus, PubMed, and EMBASE. Only English papers were included; both pediatric and adult studies were accepted. Duplicate studies, case reports, letters to the editor, and meeting abstracts were excluded. Main findings Twenty-one papers were selected. Several methods have been proposed for suction use in RIRS, such as through the ureteral access sheath or directly to the scope. Artificial intelligence can also regulate this system, monitoring pressure and perfusion flow values. All the proposed techniques showed satisfactory perioperative results for operative time, stone-free rate (SFR), and residual fragments. Moreover, the reduction of intrarenal pressure (induced by aspiration) was also associated with a lower infection rate. Even the studies that considered kidney stones with a diameter of 20mm or higher reported higher SFR and reduced postoperative complications. However, the lack of well-defined settings for suction pressure and fluid flow prevents the standardization of the procedure. Conclusion Aspiration device in the surgical treatment of urinary stones favours a higher SFR, reducing infectious complications, as supported by the included studies. RIRS with a suction system provided to be a natural successor to the traditional technique, regulating intrarenal pressure and aspirating fine dust. (AU)


Subject(s)
Humans , Suction/instrumentation , Nephrolithiasis/surgery
9.
Clin Oral Investig ; 26(9): 5687-5696, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35536440

ABSTRACT

OBJECTIVES: SOPs recommend high-volume evacuation (HVE) for aerosol-generating procedures (AGPs) in dentistry. Therefore, in the exploratory study, the area of splatter contamination (SCON in %) generated by high-speed tooth preparation (HSP) and air-polishing (APD) was measured when different suction cannulas of 6 mm diameter (saliva ejector (SAE)), 11 mm (HC11), or 16 mm (HC16) were utilized versus no-suction (NS). MATERIALS AND METHODS: Eighty tests were performed in a closed darkened room to measure SCON (1m circular around the manikin head (3.14 m2) via plan metrically assessment through fluorescence technique. HSP (handpiece, turbine (Kavo, Germany)) or APD (LM-ProPowerTM (Finland), Airflow®-Prophylaxis-Master (Switzerland)) for 6 min plus 5 s post-treatment were performed either without suction or with low-flow (150 l/min for SAE) or high-flow rate (250 l/min/350 l/min for HC11/HC16) suction. All tests were two-tailed (p≤0.05, Bonferroni corrected for multi-testing). RESULTS: Irrespective the AGP, SCON was higher for NS (median [25th; 75th percentiles]: 3.4% [2.6; 5.4]) versus high-flow suction (1.9% [1.5; 2.5]) (p=0.002). Low-flow suction (3.5% [2.6; 4.3]) versus NS resulted in slightly lower but not statistically significantly lower SCON (p=1.000) and was less effective than high-flow suction (p=0.003). Lowest contamination values were found with HC16 (1.9% [1.5; 2.5]; p≤0.002), whereat no significant differences were found for HC11 (2.4% [1.7; 3.1]) compared to SAE (p=0.385) or NS (p=0.316). CONCLUSIONS: Within study's limitations, the lowest splatter contamination values resulted when HC16 were utilized by a high-flow rate of ≥250 l/min. CLINICAL RELEVANCE: It is strongly recommended to utilize an HVE with suction cannulas of 16mm diameter for a high-flow rate during all AGPs and afterwards also to disinfect all surface of patients or operators contacted.


Subject(s)
Cannula , Dentistry , Suction , Tooth Preparation , Aerosols , Finland , Humans , Suction/instrumentation
11.
Acta Otolaryngol ; 141(10): 929-933, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34633896

ABSTRACT

BACKGROUND: Selective endoscopic coagulation of a nasal bleeding vessel is an effective means of treating epistaxis. Precisely locating the bleeding site(s) is critical. OBJECTIVE: To investigate the utility of combining a negative pressure suction device and endoscope in locating bleeding sites of refractory epistaxis. METHODS: A total of 116 patients with refractory epistaxis, who underwent systematic endoscopic exploration under local anesthesia in the absence of identifiable sites of bleeding were randomizely divided into two groups via negative pressure group (NPG) and control group (CG): The negative pressure suction device combined with an endoscope was used to re-explore the epistaxis. Nasal bleeding was induced using this method to help the operator locate the site of epistaxis accurately; the bleeding was then stopped using electrocoagulation with the suction electrode. The CG was treated with endoscopic re-exploration and selective tamponade. RESULTS: Compared with the CG, there were statistically significant differences in length of hospital stay, rebleeding, and postoperative pain and complications (all p < .05). CONCLUSION AND SIGNIFICANCE: Combining a negative pressure suction device and endoscope was a safe and effective technique for accurately locating bleeding sites in patients with refractory epistaxis.


Subject(s)
Endoscopes , Epistaxis/surgery , Suction/instrumentation , Case-Control Studies , Electrocoagulation , Female , Humans , Male , Middle Aged , Random Allocation , Retrospective Studies
13.
Cochrane Database Syst Rev ; 6: CD012671, 2021 06 16.
Article in English | MEDLINE | ID: mdl-34133025

ABSTRACT

BACKGROUND: Neonates born through meconium-stained amniotic fluid (MSAF) are at risk of developing meconium aspiration syndrome (MAS). Neonates who are non-vigorous due to intrapartum asphyxia are at higher risk of developing MAS. Clearance of meconium from the airways below the vocal cords by tracheal suction before initiating other steps of resuscitation may reduce the risk of development of MAS. However, conducting tracheal suction may not only be ineffective, it may also delay effective resuscitation, thus prolonging and worsening the hypoxic-ischaemic insult.  OBJECTIVES: To evaluate the efficacy of tracheal suctioning at birth in preventing meconium aspiration syndrome and other complications among non-vigorous neonates born through meconium-stained amniotic fluid. SEARCH METHODS: We used the standard search strategy of Cochrane Neonatal to search Cochrane Central Register of Controlled Trials (CENTRAL 2020, Issue 11) in the Cochrane Library; Ovid MEDLINE(R) and Epub Ahead of Print, In-Process & Other Non-Indexed Citations, Daily and Versions(R) (1946 to 25 November 2020) for randomised controlled trials (RCTs) and quasi-randomised trials. We also searched clinical trials databases and the reference lists of retrieved articles for RCTs and quasi-randomised trials (up to November 2020). SELECTION CRITERIA: We included studies enrolling non-vigorous neonates born through MSAF, if the intervention being tested included tracheal suction at the time of birth with an intent to clear the trachea of meconium before regular breathing efforts began. Tracheal suction could be performed with an endotracheal tube or a wide-gauge suction catheter. Neonates in the control group should have been resuscitated at birth with no effort made to clear the trachea of meconium. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed trial quality and extracted data, consulting with a third review author about any disagreements. We used standard Cochrane methodological procedures, including assessment of risk of bias for all studies. Our primary outcomes were: MAS; all-cause neonatal mortality; and incidence of hypoxic-ischaemic encephalopathy (HIE). Secondary outcomes included: need for mechanical ventilation; incidence of pulmonary air leaks; culture-positive sepsis; and persistent pulmonary hypertension. We used the GRADE approach to assess the certainty of evidence. MAIN RESULTS: We included four studies (enrolling 581 neonates) in the review. All four studies were conducted in tertiary care hospitals in India. Three of the four studies included neonates born at and beyond term gestation, whereas one included neonates born at and beyond 34 weeks of gestation. Due to the nature of the intervention, it was not possible to blind the healthcare personnel conducting the intervention. Tracheal suction compared to no suction in non-vigorous neonates born through MSAF In non-vigorous infants, no differences were noted in the risks of MAS (RR 1.00, 95% CI 0.80 to 1.25; RD 0.00, 95% CI -0.07 to 0.08; 4 studies, 581 neonates) or all-cause neonatal mortality (RR 1.24, 95% CI 0.76 to 2.02; RD 0.02, 95% CI -0.03 to 0.07; 4 studies, 575 neonates) with or without tracheal suctioning. No differences were reported in the risk of any severity HIE (RR 1.05, 95% CI 0.68 to 1.63; 1 study, 175 neonates) or moderate to severe HIE (RR 0.68, 95% CI 0.43 to 1.09; 1 study, 152 neonates) among non-vigorous neonates born through MSAF. We are also uncertain as to the effect of tracheal suction on other outcomes such as incidence of mechanical ventilation (RR 0.99, 95% CI 0.68 to 1.44; RD 0.00, 95% CI -0.06 to 0.06; 4 studies, 581 neonates), pulmonary air leaks (RR 1.22, 95% CI 0.38 to 3.93; RD 0.00, 95% CI -0.02 to 0.03; 3 studies, 449 neonates), persistent pulmonary hypertension (RR 1.29, 95% CI 0.60 to 2.77; RD 0.02, 95% CI -0.03 to 0.06; 3 studies, 406 neonates) and culture-positive sepsis (RR 1.32, 95% CI 0.48 to 3.57; RD 0.01, 95% CI -0.03 to 0.05; 3 studies, 406 neonates). All reported outcomes were judged as providing very low certainty evidence. AUTHORS' CONCLUSIONS: We are uncertain about the effect of tracheal suction on the incidence of MAS and its complications among non-vigorous neonates born through MSAF. One study awaits classification and could not be included in the review. More research from well-conducted large trials is needed to conclusively answer the review question.


Subject(s)
Amniotic Fluid , Meconium Aspiration Syndrome/prevention & control , Suction/methods , Trachea , Bias , Bronchodilator Agents/administration & dosage , Cardiopulmonary Resuscitation , Cause of Death , Confidence Intervals , Epinephrine/administration & dosage , Humans , Hypertension, Pulmonary/epidemiology , Hypoxia-Ischemia, Brain/epidemiology , Incidence , India , Infant , Infant Mortality , Infant, Newborn , Intubation, Intratracheal/instrumentation , Randomized Controlled Trials as Topic , Respiration, Artificial/statistics & numerical data , Sepsis/epidemiology , Suction/instrumentation
14.
World J Urol ; 39(11): 4255-4260, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34032912

ABSTRACT

PURPOSE: To compare double-sheath vacuum suction minimally invasive percutaneous nephrolithotomy (DS-mini-PCNL) with vacuum-assisted mini-PCNL (VS-mini-PCNL) and to better define the potential benefits of DS-mini-PCNL. METHODS: Between July 2019 and May 2020, 117 patients with large radiopaque renal stones underwent mini-PCNL. Of these, 63 underwent DS-mini-PCNL and 54 underwent VS-mini-PCNL. For VS-mini-PCNL, a F20 Y-shaped sheath was used and the oblique arm of the sheath was connected to the vacuum suction. For DS-mini-PCNL, the oblique arm of a F20 Y-shaped sheath (the outer sheath) and a F16 Y-shaped sheath (the inner sheath) was connected to the perfusion inflow and the vacuum suction, respectively. A 550-µm holmium-YAG laser was used for stone fragmentation. RESULTS: Compared with VS-mini-PCNL group, DS-mini-PCNL group had significantly shorter operative time (35.78 ± 7.77 min vs. 44.56 ± 13.19 min; P = 0.000) and significantly lower fever rate (1.6% vs. 11.1%; P = 0.048). It was not significantly different between the two groups despite the higher initial stone-free rate seen for DS-mini-PCNL group relative to VS-mini-PCNL group (87.7% vs. 81.5%, P = 0.346). Auxiliary procedure rates were 4.8% (three patients) in DS-mini-PCNL group and 16.7% (nine patients) in VS-mini-PCNL group, with a significant difference (P = 0.034). The difference in the final stone-free rate between the two groups was rendered insignificant (93.8% vs. 89.1%, P = 0.510). CONCLUSIONS: DS-mini-PCNL is a safe and effective modality for large renal stones, which could increase the efficiency of stone extraction and decrease infectious complications compared with VS-mini-PCNL.


Subject(s)
Kidney Calculi/surgery , Nephrolithotomy, Percutaneous/instrumentation , Nephrolithotomy, Percutaneous/methods , Suction/instrumentation , Adult , Equipment Design , Female , Humans , Kidney Calculi/pathology , Male , Middle Aged , Minimally Invasive Surgical Procedures , Retrospective Studies , Vacuum
15.
BMC Neurol ; 21(1): 176, 2021 Apr 24.
Article in English | MEDLINE | ID: mdl-33892652

ABSTRACT

BACKGROUND: Migraine is a primary headache disorder and is the most common disabling primary headache disorder that occurs in children and adolescents. A recent study showed that paranasal air suction can provide relief to migraine headache. However, in order to get the maximum benefit out of it, an easy to use effective air sucker should be available. Aiming to fulfil the above requirement, a randomized, double blind control clinical trial was conducted to investigate the efficacy of a recently developed low-pressure portable air sucker. METHODS: Eighty-six Sri Lankan school children of age 16-19 years with migraine were enrolled for the study. They were randomly allocated into two groups, and one group was subjected to six intermittent ten-second paranasal air suctions using the portable air sucker for 120 s. The other group was subjected to placebo air suction (no paranasal air suction). The effect of suction using portable air sucker was the primary objective but side of headache, type of headache, and gender were also studied as source variables. The primary response studied was severity of headache. In addition, left and right supraorbital tenderness, photophobia, phonophobia, numbness over the face and scalp, nausea and generalized tiredness/weakness of the body were studied. The measurements on all those variables were made before and after suction, and the statistical analysis was performed based on before and after differences. As a follow-up, patients were monitored for 24-h period. RESULTS: There was a significant reduction in the severity of headache pain (OR = 25.98, P < 0.0001), which was the primary outcome variable, and other migraine symptoms studied, tenderness (left) (OR = 289.69, P < 0.0001), tenderness (right) (OR > 267.17, P < 0.0001), photophobia (OR = 2115.6, P < 0.0001), phonophobia (OR > 12.62, P < 0.0001) nausea (OR > 515.59, P < 0.0001) and weakness (OR = 549.06, P < 0.0001) except for numbness (OR = 0.747, P = 0.67) in the treatment group compared to the control group 2 min after the suction. These symptoms did not recur within 24-h period and there were no significant side effects recorded during the 24-h observation period. CONCLUSION: This pilot study showed that low-pressure portable air sucker is effective in paranasal air suction, and suction for 120 s using the sucker can provide an immediate relief which can last for more than 24-h period without any side effects. TRAIL REGISTRATION: Clinical Trial Government Identification Number - 1548/2016. Ethical Clearance Granted Institute - Medical Research Institute, Colombo, Sri Lanka (No 38/2016). Sri Lanka Clinical Trial Registration No: SLCTR/2017/018 . Date of registration = 29/ 06/2017. Approval Granting Organization to use the device in the clinical trial- National Medicines Regulatory Authority Sri Lanka (16 Jan 2018), The device won award at Geneva international inventers exhibition in 2016 and President award in 2018 in Sri Lanka. It is a patented device in Sri Lanka and patent number was SLKP/1/18295. All methods were carried out in accordance with CONSORT 2010 guidelines.


Subject(s)
Migraine Disorders/therapy , Paranasal Sinuses , Suction/instrumentation , Suction/methods , Adolescent , Double-Blind Method , Female , Humans , Male , Pilot Projects , Sri Lanka , Treatment Outcome , Young Adult
16.
Ann Thorac Surg ; 112(5): e381-e382, 2021 11.
Article in English | MEDLINE | ID: mdl-33744221

ABSTRACT

In robotic-assisted thoracoscopic surgery, surgeons may encounter bleeding issues requiring compression techniques and time to achieve hemostasis. During this time, surgeons cannot use the robot arm and may require an assistant to perform suction, thus increasing the cost of the procedure. This report describes an alternative suction device, Dobon (Senko Medical Instrument Mfg, Tokyo, Japan), which is usually used for pediatric cardiac surgery, for use in robotic-assisted thoracoscopic surgery. The report presents the technique for using this device and comments on the advantages, including decreased cost and an improved surgical visual field.


Subject(s)
Pneumonectomy/methods , Robotic Surgical Procedures , Suction/instrumentation , Thoracoscopy , Equipment Design , Humans
18.
PLoS One ; 16(3): e0247845, 2021.
Article in English | MEDLINE | ID: mdl-33657165

ABSTRACT

PURPOSE: Increased blood loss remains a major drawback of simultaneous bilateral total hip arthroplasty (SBTHA). We examined the effects of disusing closed suction drainage (CSD) on postoperative blood loss and transfusion requirement in cementless SBTHA. METHODS: A retrospective cohort study was conducted with a consecutive series of cementless SBTHAs performed by a single surgeon between January 2014 and March 2017. The surgeon routinely used CSD until May 2015 and refrained from CSD in all primary THAs thereafter. This study included SBTHAs with intravenous administration of tranexamic acid (TXA). Postoperative hemoglobin drop, blood loss, transfusion rate, pain scores, complication rates, and implant survivorships were compared between the groups of SBTHA with and without CSD. The minimum follow-up duration was 1 year. RESULTS: Among the 110 patients (220 hips), 46 (92 hips) and 64 (128 hips) underwent SBTHA with and without CSD, respectively. Maximum hemoglobin drop (mean, 4.8 vs. 3.9 g/dL; P = 0.001), calculated blood loss (mean, 1530 vs. 1190 mL; P<0.001), transfusion rate (45.7% vs. 21.9%; P = 0.008), and length of hospital stay (mean, 6.6 vs. 5.8 days; P = 0.004) were significantly lower in patients without CSD. There were no significant differences in postoperative pain scales and wound complication rates. The mean Harris Hip scores at final follow-up (92.5 vs. 92.1; P = 0.775) and implant survivorships with an end-point of any revision at 4 years (98.9% vs. 98.4%; log-rank, P = 0.766) were similar between groups. CONCLUSIONS: Disusing CSD significantly reduced postoperative blood loss and transfusion requirement without increasing postoperative pain and surgical wound complications in cementless SBTHA with concurrent administration of intravenous TXA.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Suction/instrumentation , Adult , Antifibrinolytic Agents/therapeutic use , Arthroplasty, Replacement, Hip/adverse effects , Blood Transfusion , Female , Humans , Middle Aged , Postoperative Hemorrhage/etiology , Postoperative Hemorrhage/therapy , Retrospective Studies , Suction/adverse effects , Tranexamic Acid/therapeutic use
19.
Ann Otol Rhinol Laryngol ; 130(11): 1245-1253, 2021 Nov.
Article in English | MEDLINE | ID: mdl-33730891

ABSTRACT

OBJECTIVES: Define aerosol and droplet risks associated with routine otolaryngology clinic procedures during the COVID-19 era. METHODS: Clinical procedures were simulated in cadaveric heads whose oral and nasal cavities were coated with fluorescent tracer (vitamin B2) and breathing was manually simulated through retrograde intubation. A cascade impactor placed adjacent to the nares collected generated particles with aerodynamic diameters ≤14.1 µm. The 3D printed models and syringes were used to simulate middle and external ear suctioning as well as open suctioning, respectively. Provider's personal protective equipment (PPE) and procedural field contamination were also recorded for all trials using vitamin B2 fluorescent tracer. RESULTS: The positive controls of nebulized vitamin B2 produced aerosol particles ≤3.30 µm and endonasal drilling of a 3D model generated particles ≤14.1 µm. As compared with positive controls, aerosols and small droplets with aerodynamic diameter ≤14.1 µm were not detected during rigid nasal endoscopy, flexible fiberoptic laryngoscopy, and rigid nasal suction of cadavers with simulated breathing. There was minimal to no field contamination in all 3 scenarios. Middle and external ear suctioning and open container suctioning did not result in any detectable droplet contamination. The clinic suction unit contained all fluorescent material without surrounding environmental contamination. CONCLUSION: While patients' coughing and sneezing may create a baseline risk for providers, this study demonstrates that nasal endoscopy, flexible laryngoscopy, and suctioning inherently do not pose an additional risk in terms of aerosol and small droplet generation. An overarching generalization cannot be made about endoscopy or suctioning being an aerosol generating procedure. LEVEL OF EVIDENCE: 3.


Subject(s)
Aerosols/adverse effects , COVID-19 , Disease Transmission, Infectious/prevention & control , Endoscopy , Otolaryngology , Risk Adjustment/methods , Suction , COVID-19/prevention & control , COVID-19/transmission , Cadaver , Endoscopy/adverse effects , Endoscopy/instrumentation , Endoscopy/methods , Humans , Otolaryngology/methods , Otolaryngology/standards , Outcome Assessment, Health Care , Personal Protective Equipment/classification , Personal Protective Equipment/virology , Research Design , Risk Assessment/methods , SARS-CoV-2 , Suction/adverse effects , Suction/instrumentation , Suction/methods
20.
Dermatol Surg ; 47(2): 245-249, 2021 02 01.
Article in English | MEDLINE | ID: mdl-33565777

ABSTRACT

BACKGROUND: Suction-curettage using an arthroscopic shaver is the most effective surgical treatment for bromhidrosis; however, information regarding the procedure is limited. This study investigated the factors that affect the efficacy of suction-curettage. PATIENTS AND METHODS: We retrospectively evaluated data for 215 patients (430 axillae) with bromhidrosis treated with suction-curettage using an arthroscopic shaver between 2011 and 2019. RESULTS: Excellent or good efficacy with improved malodor was achieved in 418 axillae (97.21%). Secondary suction-curettage was performed for 11 (2.56%), with excellent results. Efficacy and need for secondary suction-curettage were not associated with age, sex, shaving time, and tumescent infiltration use. Complications were observed in 52 (12.09%) axillae, including hematoma or seroma, epidermis decortication, skin necrosis, and infections; 10 (2.33%) required local debridement for wounds. Complications showed a significant difference with respect to age (p < .001). Pain scores on postoperative Day 2 were significantly lower for patients treated using tumescent infiltration than those for the others (1.65 ± 0.84 vs 4.57 ± 1.16; p < .001). CONCLUSION: The results suggest that 7 to 15 minutes of suction curettage using an arthroscopic shaver is sufficient to achieve good efficacy for bromhidrosis with few complications. Older age was a risk factor for complications, and tumescent infiltration use achieved good postoperative pain control. LEVELS OF EVIDENCE: II.


Subject(s)
Anesthesia, Local , Curettage/instrumentation , Epinephrine , Hyperhidrosis/surgery , Surgical Wound Infection/etiology , Vasoconstrictor Agents , Anesthetics, Local , Axilla/surgery , Curettage/adverse effects , Debridement , Female , Hematoma/etiology , Humans , Lidocaine , Male , Necrosis/etiology , Necrosis/surgery , Odorants , Pain, Postoperative/etiology , Reoperation , Retrospective Studies , Seroma/etiology , Skin/pathology , Suction/instrumentation , Surgical Wound Infection/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...