Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.388
Filter
1.
Tech Coloproctol ; 28(1): 76, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38954099

ABSTRACT

BACKGROUND: Colorectal anastomotic leakage causes severe consequences for patients and healthcare system as it will lead to increased consumption of hospital resources and costs. Technological improvements in anastomotic devices could reduce the incidence of leakage and its economic impact. The aim of the present study was to assess if the use of a new powered circular stapler is cost-effective. METHOD: This observational study included patients undergoing left-sided circular stapled colorectal anastomosis between January 2018 and December 2021. Propensity score matching was carried out to create two comparable groups depending on whether the anastomosis was performed using a manual or powered circular device. The rate of anastomotic leakage, its severity, the consumption of hospital resources, and its cost were the main outcome measures. A cost-effectiveness analysis comparing the powered circular stapler versus manual circular staplers was performed. RESULTS: A total of 330 patients were included in the study, 165 in each group. Anastomotic leakage rates were significantly different (p = 0.012): 22 patients (13.3%) in the manual group versus 8 patients (4.8%) in the powered group. The effectiveness of the powered stapler and manual stapler was 98.27% and 93.69%, respectively. The average cost per patient in the powered group was €6238.38, compared with €9700.12 in the manual group. The incremental cost-effectiveness ratio was - €74,915.28 per patient without anastomotic complications. CONCLUSION: The incremental cost of powered circular stapler compared with manual devices was offset by the savings from lowered incidence and cost of management of anastomotic leaks.


Subject(s)
Anastomosis, Surgical , Anastomotic Leak , Colon , Cost-Benefit Analysis , Rectum , Surgical Staplers , Surgical Stapling , Humans , Anastomotic Leak/prevention & control , Anastomotic Leak/economics , Anastomotic Leak/etiology , Female , Surgical Staplers/economics , Male , Anastomosis, Surgical/adverse effects , Anastomosis, Surgical/economics , Anastomosis, Surgical/instrumentation , Anastomosis, Surgical/methods , Middle Aged , Aged , Incidence , Surgical Stapling/economics , Surgical Stapling/methods , Surgical Stapling/adverse effects , Surgical Stapling/instrumentation , Colon/surgery , Rectum/surgery , Propensity Score , Adult , Cost-Effectiveness Analysis
2.
Tech Coloproctol ; 28(1): 82, 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38981897

ABSTRACT

BACKGROUND: Although functional end-to-end anastomosis (FEEA) using a stapler in the colorectal field has been recognised worldwide, the technique varies by surgeon, and the safety of anastomosis using different techniques is unknown. METHODS: This multicentre prospective observational cohort study was conducted by the KYCC Study Group in Yokohama, Japan, and included patients who underwent colonic resection at seven centres between April 2020 and March 2022. This study compared the incidence of surgery-related abdominal complications (SAC: anastomotic leakage [AL], anastomotic bleeding, intra-abdominal abscess, enteritis, ileus, surgical site infection, and other abdominal complications) between two different methods of FEEA (one-step [OS] method: simultaneous anastomosis and bowel resection; two-step [TS] method: anastomosis after bowel resection). Complications of Clavien-Dindo classification grade 2 or higher were assessed. RESULTS: Among 293 eligible cases, the OS and TS methods were used in 194 (66.2%) and 99 (33.8%) patients, respectively. The baseline characteristics were similar between the groups. The OS method used fewer staplers (three vs. four staplers, p < 0.00001). There were no significant differences in SAC rate between the OS (19.1%) and the TS (16.2%) groups (p = 0.44). The OS group had four cases (2.1%) of AL (two patients; grade 3, two patients; grade 2) while the TS group had one case (1.0%) of grade 2 AL (p = 0.67). Multivariate logistic regression analysis showed that male sex (odds ratio [OR] 3.95; p < 0.00001), an open surgical approach (OR 2.36; p = 0.03), and longer operative duration (OR,2.79; p = 0.002) were independent predictors of complications, whereas the OS method was not an independent predictor (OR 1.17; p = 0.66). CONCLUSIONS: The OS and the TS technique for stapled colonic anastomosis in a FEEA had a similar postoperative complication rate. TRIAL REGISTRATION NUMBER: UMIN000039902 (registration date 23 March 2020).


Subject(s)
Anastomosis, Surgical , Colectomy , Postoperative Complications , Humans , Male , Female , Anastomosis, Surgical/methods , Anastomosis, Surgical/adverse effects , Prospective Studies , Aged , Japan , Middle Aged , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Colectomy/methods , Colectomy/adverse effects , Colon/surgery , Anastomotic Leak/etiology , Anastomotic Leak/epidemiology , Incidence , Aged, 80 and over , Surgical Stapling/methods , East Asian People
3.
Langenbecks Arch Surg ; 409(1): 184, 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38862717

ABSTRACT

PURPOSE: Post-operative pancreatic fistula (POPF) remains the main complication after distal pancreatectomy (DP). The aim of this study is to evaluate the potential benefit of different durations of progressive stapler closure on POPF rate and severity after DP. METHODS: Patients who underwent DP between 2016 and 2023 were retrospectively enrolled and divided into two groups according to the duration of the stapler closure: those who underwent a progressive compression for < 10 min and those for ≥ 10 min. RESULTS: Among 155 DPs, 83 (53.5%) patients underwent pre-firing compression for < 10 min and 72 (46.5%) for ≥ 10 min. As a whole, 101 (65.1%) developed POPF. A lower incidence rate was found in case of ≥ 10 min compression (34-47.2%) compared to < 10 min compression (67- 80.7%) (p = 0.001). When only clinically relevant (CR) POPFs were considered, a prolonged pre-firing compression led to a lower rate (15-20.8%) than the < 10 min cohort (32-38.6%; p = 0.02). At the multivariate analysis, a compression time of at least 10 min was confirmed as a protective factor for both POPF (OR: 5.47, 95% CI: 2.16-13.87; p = 0.04) and CR-POPF (OR: 2.5, 95% CI: 1.19-5.45; p = 0.04) development. In case of a thick pancreatic gland, a prolonged pancreatic compression for at least 10 min was significantly associated to a lower rate of CR-POPF compared to < 10 min (p = 0.04). CONCLUSION: A prolonged pre-firing pancreatic compression for at least 10 min seems to significantly reduce the risk of CR-POPF development. Moreover, significant advantages are documented in case of a thick pancreatic gland.


Subject(s)
Pancreatectomy , Pancreatic Fistula , Postoperative Complications , Surgical Stapling , Humans , Pancreatic Fistula/prevention & control , Pancreatic Fistula/etiology , Pancreatectomy/adverse effects , Pancreatectomy/methods , Male , Female , Retrospective Studies , Middle Aged , Aged , Postoperative Complications/prevention & control , Postoperative Complications/etiology , Surgical Stapling/methods , Surgical Staplers , Adult , Time Factors , Pancreatic Neoplasms/surgery
4.
Int J Colorectal Dis ; 39(1): 85, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38837095

ABSTRACT

BACKGROUND: Rectal cancer (RC) is a surgical challenge due to its technical complexity. The double-stapled (DS) technique, a standard for colorectal anastomosis, has been associated with notable drawbacks, including a high incidence of anastomotic leak (AL). Low anterior resection with transanal transection and single-stapled (TTSS) anastomosis has emerged to mitigate those drawbacks. METHODS: Observational study in which it described the technical aspects and results of the initial group of patients with medium-low RC undergoing elective laparoscopic total mesorectal excision (TME) and TTSS. RESULTS: Twenty-two patients were included in the series. Favourable postoperative outcomes with a median length of stay of 5 days and an AL incidence of 9.1%. Importantly, all patients achieved complete mesorectal excision with tumour-free margins, and no mortalities were reported. CONCLUSION: TTSS emerges as a promising alternative for patients with middle and lower rectal tumours, offering potential benefits in terms of morbidity reduction and oncological integrity compared with other techniques.


Subject(s)
Anal Canal , Anastomosis, Surgical , Rectal Neoplasms , Surgical Stapling , Humans , Male , Female , Anastomosis, Surgical/methods , Middle Aged , Aged , Rectal Neoplasms/surgery , Anal Canal/surgery , Surgical Stapling/methods , Treatment Outcome , Rectum/surgery , Laparoscopy/methods , Anastomotic Leak/etiology , Anastomotic Leak/prevention & control , Adult , Aged, 80 and over
5.
JSLS ; 28(2)2024.
Article in English | MEDLINE | ID: mdl-38910956

ABSTRACT

Background and Objectives: Haemostasis-related complications associated with Medtronic Tri-stapleTM with preloaded buttress material and the novel, naked AEONTM gastrointestinal staplers have not been extensively studied in bariatric surgery. The study aimed to assess and compare the 30-day haemostasis-related complications between Medtronic Tri-stapleTM and AEONTM GIA staplers. Methods: A retrospective analysis was performed on data from patients who underwent primary or revision sleeve gastrectomy (SG) or the sleeve component of single anastomosis duodeno-ileal bypass with SG (SADI-S) in a private hospital in Australia between November 2021 and December 2022. The surgeries were performed by a single surgeon, using either Medtronic Tri-stapleTM or AEONTM staplers. Results: The analysis included 250 patients, with the first 125 consecutive patients receiving staple line using the Medtronic Tri-stapleTM GIA stapler and the subsequent 125 patients receiving staple line using the AEONTM GIA stapler. Statistical analysis revealed no significant differences in the distribution of surgical procedures between the Medtronic and AEON groups. In the AEON group, there were statistically higher numbers of diabetics and former tobacco users, while other preoperative characteristics did not significantly differ between the two groups. The AEON group had a significantly longer mean operative time, while the length of hospital stay was significantly shorter. No intraoperative or 30-day complications, deaths, emergency room visits, readmissions, or reoperations were observed in either group. Conclusion: The novel, naked AEONTM stapler demonstrated non-inferiority to the established Medtronic Tri-StapleTM with preloaded buttress material in achieving hemostasis and maintaining staple-line integrity in bariatric surgery.


Subject(s)
Bariatric Surgery , Surgical Staplers , Surgical Stapling , Humans , Retrospective Studies , Female , Male , Bariatric Surgery/methods , Middle Aged , Surgical Stapling/methods , Adult , Obesity, Morbid/surgery , Hemostasis, Surgical/instrumentation , Hemostasis, Surgical/methods , Gastrectomy/methods , Equipment Design
6.
Asian J Endosc Surg ; 17(3): e13340, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38925165

ABSTRACT

INTRODUCTION: This study evaluates surgical outcomes of minimally invasive Ivor Lewis esophagectomy (ILE) for esophageal and esophagogastric cancer, with the comparison of the robotic approach (RA) and the conventional minimally invasive approach (CA). METHODS: Selected patients who underwent minimally invasive ILE for esophageal cancer were included between January 2017 and December 2023. We retrospectively investigated the patients' background characteristics and the short-term surgical outcomes. RESULTS: In this period, among a total of 840 esophagectomies, 81 patients (9.6%) underwent minimally invasive ILE, consisting of 24 cases with RA and 57 with CA. The major indications for ILE were adenocarcinoma of the distal esophagus or esophagogastric junction and patients with prior head and neck cancer treatment. Among these thoracic approaches, there were no significant differences in the patients' indications and characteristics, including age, histology, tumor location, clinical TNM stage, and preoperative therapy. Compared with the CA group, no anastomotic leakage was observed in the RA group (17.5% vs. 0, p = .035). Rates of total postoperative complications and length of hospital stay also tended to be reduced in the RA group but did not reach significance. CONCLUSION: In the Ivor Lewis esophagectomy with a side-to-side linear-stapled anastomosis, the fully robotic approach has the potential to powerfully reduce anastomotic leakage compared to the conventional minimally invasive approach.


Subject(s)
Anastomosis, Surgical , Anastomotic Leak , Esophageal Neoplasms , Esophagectomy , Robotic Surgical Procedures , Humans , Esophagectomy/methods , Male , Robotic Surgical Procedures/methods , Female , Esophageal Neoplasms/surgery , Anastomotic Leak/etiology , Anastomotic Leak/prevention & control , Anastomotic Leak/epidemiology , Middle Aged , Retrospective Studies , Aged , Anastomosis, Surgical/methods , Surgical Stapling/methods , Minimally Invasive Surgical Procedures/methods , Adenocarcinoma/surgery , Adenocarcinoma/pathology , Length of Stay/statistics & numerical data , Treatment Outcome , Adult
7.
BMJ Case Rep ; 17(5)2024 May 13.
Article in English | MEDLINE | ID: mdl-38740444

ABSTRACT

With the advancements in the medical field, many innovations in medical devices have happened. Using a surgical stapler to close the laryngectomy defect without opening the pharynx is particularly advantageous in a total laryngectomy (TL). However, performing the tracheoesophageal puncture (TEP) during stapler closure of the larynx has not been widely advocated, due to the fear of complications related to the procedure.We treated two male patients with advanced glottic malignancy who underwent a TL. To restore their ability to speak, we performed a primary TEP and immediate voice prosthesis placement. After the TEP, we closed the larynx using a stapler. The surgical technique used in this procedure has been thoroughly explained.The use of a surgical stapler for pharyngeal closure during a TL has several advantages, particularly with regard to the duration of surgery. The current techniques appear to be promising in reducing TEP-related complications during stapler-assisted laryngeal closure.


Subject(s)
Laryngeal Neoplasms , Laryngectomy , Punctures , Trachea , Humans , Esophagus/surgery , Laryngeal Neoplasms/surgery , Laryngectomy/methods , Laryngectomy/adverse effects , Larynx/surgery , Larynx, Artificial , Punctures/methods , Surgical Staplers , Surgical Stapling/methods , Trachea/surgery
9.
Surg Laparosc Endosc Percutan Tech ; 34(3): 290-294, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38736400

ABSTRACT

BACKGROUND: Despite the success of bariatric surgery in treating obesity, it can still lead to complications. The most serious and feared technical complications are bleeding and leakage from the gastric staple line. In this study, stapler line reinforcement was investigated to determine whether it affects postoperative leakage and bleeding rates and their management. MATERIALS AND METHODS: Overall, 510 patients who underwent sleeve gastrectomy were evaluated retrospectively. They were divided into 2 groups according to whether reinforcement of the staple line with running imbricating sutures was performed. RESULTS: In the reinforcement group, there were two leaks (0.7%), which were diagnosed seven and eight days after surgery. In the non-reinforcement group, there were nine leaks (4%). There was no difference between the two groups in staple line bleeding. CONCLUSIONS: This study shows that reinforcement with continuous imbricating sutures is associated with less stapler line leakage and a lower reoperation rate at the cost of increased operative time.


Subject(s)
Anastomotic Leak , Gastrectomy , Laparoscopy , Obesity, Morbid , Surgical Stapling , Humans , Female , Male , Retrospective Studies , Laparoscopy/methods , Adult , Gastrectomy/methods , Gastrectomy/adverse effects , Surgical Stapling/methods , Anastomotic Leak/prevention & control , Anastomotic Leak/etiology , Obesity, Morbid/surgery , Middle Aged , Treatment Outcome , Suture Techniques , Reoperation , Operative Time , Postoperative Complications/prevention & control , Postoperative Complications/etiology
10.
Dis Colon Rectum ; 67(S1): S26-S35, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38710588

ABSTRACT

BACKGROUND: Available techniques for IPAA in ulcerative colitis include handsewn, double-stapled, and single-stapled anastomoses. There are controversies, indications, and different outcomes regarding these techniques. OBJECTIVE: To describe technical details, indications, and outcomes of 3 specific types of anastomoses in restorative proctocolectomy. DATA SOURCE: Systematic literature review for articles in the PubMed database according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses criteria. STUDY SELECTION: Studies describing outcomes of the 3 different types of anastomoses, during pouch surgery, in patients undergoing restorative proctocolectomy for ulcerative colitis. INTERVENTION: IPAA technique. MAIN OUTCOME MEASURES: Postoperative outcomes (anastomotic leaks, overall complication rates, and pouch function). RESULTS: Twenty-one studies were initially included: 6 studies exclusively on single-stapled IPAA, 2 exclusively on double-stapled IPAA, 6 studies comparing single-stapled to double-stapled techniques, 6 comparing double-stapled to handsewn IPAA, and 1 comprising single-stapled to handsewn IPAA. Thirty-seven studies were added according to authors' discretion as complementary evidence. Between 1990 and 2015, most studies were related to double-stapled IPAA, either only analyzing the results of this technique or comparing it with the handsewn technique. Studies published after 2015 were mostly related to transanal approaches to proctectomy for IPAA, in which a single-stapled anastomosis was introduced instead of the double-stapled anastomosis, with some studies comparing both techniques. LIMITATIONS: A low number of studies with handsewn IPAA technique and a large number of studies added at authors' discretion were the limitations of this strudy. CONCLUSIONS: Handsewn IPAA should be considered if a mucosectomy is performed for dysplasia or cancer in the low rectum or, possibly, for re-do surgery. Double-stapled IPAA has been more widely adopted for its simplicity and for the advantage of preserving the anal transition zone, having lower complications, and having adequate pouch function. The single-stapled IPAA offers a more natural design, is feasible, and is associated with reasonable outcomes compared to double-stapled anastomosis. See video from symposium.


Subject(s)
Anastomosis, Surgical , Colitis, Ulcerative , Proctocolectomy, Restorative , Humans , Colitis, Ulcerative/surgery , Proctocolectomy, Restorative/methods , Proctocolectomy, Restorative/adverse effects , Anastomosis, Surgical/methods , Anastomosis, Surgical/adverse effects , Surgical Stapling/methods , Anastomotic Leak/etiology , Anastomotic Leak/epidemiology , Colonic Pouches/adverse effects , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Treatment Outcome
11.
BMC Surg ; 24(1): 130, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38698365

ABSTRACT

BACKGROUND: Anastomosis configuration is an essential step in treatment to restore continuity of the gastrointestinal tract following bowel resection in patients with Crohn's disease (CD). However, the association between anastomotic type and surgical outcome remains controversial. This retrospective study aimed to compare early postoperative complications and surgical outcome between stapler and handsewn anastomosis after bowel resection in Crohn's disease. METHODS: Between 2001 and 2018, a total of 339 CD patients underwent bowel resection with anastomosis. Patient characteristics, intraoperative data, early postoperative complications, and outcomes were analyzed and compared between two groups of patients. Group 1 consisted of patients with stapler anastomosis and group 2 with handsewn anastomosis. RESULTS: No significant difference was found in the incidence of postoperative surgical complications between the stapler and handsewn anastomosis groups (25% versus 24.4%, p = 1.000). Reoperation for complications and postoperative hospital stay were similar between the two groups. CONCLUSION: Our analysis showed that there were no differences in anastomotic leak, nor postoperative complications, mortality, reoperation for operative complications, or postoperative hospital stay between the stapler anastomosis and handsewn anastomosis groups.


Subject(s)
Anastomosis, Surgical , Crohn Disease , Postoperative Complications , Surgical Stapling , Humans , Crohn Disease/surgery , Female , Male , Anastomosis, Surgical/methods , Retrospective Studies , Adult , Surgical Stapling/methods , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Middle Aged , Suture Techniques , Reoperation/statistics & numerical data , Treatment Outcome , Length of Stay/statistics & numerical data , Anastomotic Leak/epidemiology , Anastomotic Leak/etiology , Young Adult
13.
Colorectal Dis ; 26(4): 754-759, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38443753

ABSTRACT

AIM: Creation of an overlapped anastomosis using handsewn sutures for common enterotomy is very popular in robotic right colectomy (RRC) with intracorpareal anastomosis (IA). The aim of this study is to present a simple method for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in RRC with IA. METHOD: The distal ileum and proximal colon were put in overlapping positions. Enterotomies were created 2 cm proximal to the ileal stump and 8 cm distal to the colonic stump on the antimesenteric side. Subsequently, a 60 mm linear stapler with a reinforced bioabsorbable material was inserted into each lumen and fired. Finally, the bowel was elevated while holding the bioabsorbable material, and the common enterotomy was grasped with the robotic instrument in the middle and closed using a linear stapler with a reinforced bioabsorbable material. RESULTS: This technique was applied to 10 patients with tumours of the caecum, ascending colon, or transverse colon. The median operating time, anastomosis construction time, blood loss, and postoperative stay were 281 min (range 228-459 min), 12 min (range 11-17 min), 10 mL (range 0-110 mL), and 10 days (range 8-15 days), respectively. No adverse intraoperative events were observed. Postoperatively, one patient developed chylous ascites, but there were no other complications. CONCLUSION: The simple technique for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in robotic right colectomy with intracorporeal anastomosis appears to be safe and feasible.


Subject(s)
Absorbable Implants , Anastomosis, Surgical , Colectomy , Colonic Neoplasms , Ileum , Robotic Surgical Procedures , Surgical Staplers , Colectomy/methods , Colectomy/instrumentation , Humans , Anastomosis, Surgical/methods , Anastomosis, Surgical/instrumentation , Robotic Surgical Procedures/methods , Robotic Surgical Procedures/instrumentation , Male , Female , Middle Aged , Aged , Colonic Neoplasms/surgery , Ileum/surgery , Sutureless Surgical Procedures/methods , Sutureless Surgical Procedures/instrumentation , Operative Time , Colon/surgery , Treatment Outcome , Surgical Stapling/methods , Surgical Stapling/instrumentation , Adult , Length of Stay
14.
Vet Surg ; 53(4): 733-741, 2024 May.
Article in English | MEDLINE | ID: mdl-38444078

ABSTRACT

OBJECTIVE: To compare time to construct completion and leak testing between hand-sewn and skin staple anastomoses and enterotomies in cats. STUDY DESIGN: Ex vivo, randomized study. ANIMALS: Fresh feline cadavers (n = 20). METHODS: Jejunal segments (8 cm) were harvested and tested on the same day as euthanasia. From each cadaver, one segment was randomly assigned to control (C), hand-sewn enterotomy (HSE), and skin staple enterotomy (SSE) groups, and two segments were randomly assigned to hand-sewn anastomosis (HSA) and skin staple anastomosis (SSA) groups. Construct completion time, initial leak pressure (ILP), and maximum intraluminal pressure were compared. Leakage location was reported. RESULTS: Mean time (s) ± SD was longer (p < .001) for HSA (317.0 ± 50.9) than SSA (160.8 ± 13.1) and for HSE (172.0 ± 36.5) than SSE (20.3 ± 5.0). ILP (mean ± SD) for C (600.0 mmHg ±0.0) was higher (p < .001) than all constructs. ILP (mean ± SD) for SSA (124.2 mmHg ±83.7) was not different (p = .49) than HSA (86.1 ± 51.9), but HSE (200.3 ± 114.7) was higher (p < .001) than SSE (32.2 ± 39.7). Immediate leakage from the center of enterotomy closure was observed in 7/20 SSE. CONCLUSIONS: HSA construct completion took twice as long as SSA with no difference in intraluminal pressures. Although HSE construct completion took 8x as long as SSE, HSE had higher intraluminal pressures. CLINICAL SIGNIFICANCE: In cats, SSA may be an alternative to HSA for intestinal anastomosis, but SSE is not recommended as an alternative to HSE for intestinal enterotomy closure.


Subject(s)
Anastomosis, Surgical , Cadaver , Animals , Cats/surgery , Anastomosis, Surgical/veterinary , Anastomosis, Surgical/methods , Surgical Stapling/veterinary , Surgical Stapling/methods , Suture Techniques/veterinary , Pressure
15.
Asian J Surg ; 47(7): 3048-3055, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38431472

ABSTRACT

BACKGROUND: The potential of biodegradable magnesium (Mg) skin staple has recently garnered widespread attention due to their biodegradability and biocompatibility rather than traditional stainless steel staples, the most commonly used in current clinical practice. The aim of this study is to evaluate the safety and mechanical properties of a novel biodegradable Mg skin staple. METHODS: A prototype of Mg skin staple was designed using a novel ZK60 Mg alloy. The mechanical properties of the staple were evaluated using a universal testing machine. The cytotoxicity of the staple was examined in vitro and the efficacy of the staple in wound closure was assessed in New Zealand rabbits for one and three weeks, respectively. RESULTS: The tensile strength of this Mg alloy is 258.4 MPa with 6.9% elongation. The treatment of HaCaT and L929 cells with the staple extract resulted in over 95% cell viability, indicating no cytotoxicity. In vivo, no tissue irritation was observed. No difference was found in wound healing between the Mg skin staple and the stainless steel staple after one and three weeks in the cutting wound on the back of rabbits. Some Mg skin staples spontaneously dislodged from the skin within three weeks, while others were easily removed. CONCLUSION: Our results confirm the safety, biocompatibility, and functionality of the novel Mg skin staple in wound closure. The efficacy of the staple in wound closure was demonstrated to be as effectively as conventional staples, with the added benefit of decreased long-term retention of skin staples in the wounds.


Subject(s)
Biocompatible Materials , Magnesium , Materials Testing , Sutures , Tensile Strength , Wound Healing , Rabbits , Animals , Wound Healing/drug effects , Biocompatible Materials/administration & dosage , Humans , Surgical Stapling/methods , Alloys , Mice , Skin , Cell Survival/drug effects , Absorbable Implants
17.
Asian J Endosc Surg ; 17(2): e13293, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38452773

ABSTRACT

Vascular staplers are routinely used in laparoscopic liver resection, which has become a standard procedure in advanced medical facilities. Although previous reports have outlined the benefits of staple line reinforcement (SLR), its application in Glissonean pedicle transection during hepatic resection remains poorly studied. This study investigated surgical SLR as a tool to enhance staple line strength and improve perioperative hemostasis. Here, 10 patients who underwent laparoscopic liver resection using the Tri-StapleTM2.0 Reinforced Reload were included. Patient characteristics, surgical details, and outcomes were assessed. The results demonstrated successful outcomes with no complications related to bile leakage or injuries during staple insertion. Overall, our findings suggest that SLR can be safely utilized in Glissonean pedicle transection during laparoscopic liver resections. Further studies are required to comprehensively evaluate its benefits compared with conventional surgical staplers.


Subject(s)
Laparoscopy , Liver , Humans , Pilot Projects , Treatment Outcome , Liver/surgery , Hepatectomy/methods , Surgical Stapling/methods , Laparoscopy/methods , Sutures
19.
Colorectal Dis ; 26(4): 766-771, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38302860

ABSTRACT

AIM: Natural orifice specimen extraction (NOSE) in left-sided colorectal surgery requires application of the circular stapler anvil to the proximal bowel without exteriorization through an additional abdominal incision. We describe an intracorporeal method to secure the stapler anvil, termed the intracorporeal antimesenteric ancillary trocar (IAAT) technique. METHOD: The ancillary trocar is attached to the stapler anvil before introduction into the abdominal cavity through the anal or vaginal orifice. The colon is incised before the trocar spike is brought out through the antimesenteric surface 3-4 cm within the cut edge. A linear stapler is used to seal the bowel end. The ancillary trocar is detached and retrieved via the NOSE conduit. Following the NOSE procedure, a side-to-end colorectal anastomosis is performed with the transanal circular stapler. RESULTS: Ten consecutive patients underwent elective left-sided colorectal resection with IAAT for NOSE (seven transanal, three transvaginal) from January to June 2023. Median age and body mass index were 66 (range 47-74) years and 24.3 (range 17.9-30.8) kg/m2 respectively. Two (20%) patients underwent sigmoid colectomy for sigmoid volvulus while eight (80%) underwent anterior resection for colorectal cancer. Median operating time, operative blood loss and postoperative length of hospital stay were 170 (range 140-240) min, 20 (range 10-40) mL and 1 (range 1-3) day respectively. There were no postoperative complications, readmissions or reoperations. Median follow-up duration was 3 (range 1-6) months. CONCLUSION: The IAAT double-stapling side-to-end anastomotic technique is safe and feasible for patients undergoing left-sided colorectal resection with NOSE, resulting in good outcomes.


Subject(s)
Anastomosis, Surgical , Colectomy , Natural Orifice Endoscopic Surgery , Humans , Female , Middle Aged , Anastomosis, Surgical/methods , Anastomosis, Surgical/instrumentation , Aged , Male , Natural Orifice Endoscopic Surgery/methods , Natural Orifice Endoscopic Surgery/instrumentation , Colectomy/methods , Colectomy/instrumentation , Colon/surgery , Surgical Instruments , Vagina/surgery , Surgical Staplers , Surgical Stapling/methods , Surgical Stapling/instrumentation , Rectum/surgery , Operative Time
20.
Colorectal Dis ; 26(4): 772-775, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38372032

ABSTRACT

AIM: Total mesorectal excision with adequate free margins is the gold standard for rectal surgery. Applying a linear stapler in a narrow pelvis can be challenging and the proper distal margin difficult to assess. In selected cases the colorectal eversion technique combined with single-stapled double-purse-string anastomosis (SSDP) can be a practical solution. METHOD: Eleven patients, six men and five women, mean body mass index 27 ± 1.3 kg/m2, underwent total mesorectal excision with the colorectal eversion technique combined with modified SSDP between September 2022 and January 2023. RESULTS: The mean operative time was 190 min. The mean hospital stay was 4 days. There were no postoperative complications. The final histology showed complete mesorectal resection, circumferential resection margin negative, free distal resection margin, anastomotic doughnuts negative. At 7 ± 3 months follow-up there was no evidence of local recurrence or distant metastasis. CONCLUSION: The colorectal eversion technique combined with modified SSDP is a reproducible and safe technique in selected patients. Prospective randomized trials with large patient series are needed to confirm our preliminary results.


Subject(s)
Anastomosis, Surgical , Colon , Operative Time , Proctectomy , Rectal Neoplasms , Rectum , Surgical Stapling , Humans , Male , Female , Anastomosis, Surgical/methods , Middle Aged , Surgical Stapling/methods , Rectum/surgery , Aged , Colon/surgery , Proctectomy/methods , Rectal Neoplasms/surgery , Treatment Outcome , Suture Techniques , Margins of Excision , Length of Stay/statistics & numerical data , Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...