Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 30.122
1.
PLoS One ; 19(5): e0302778, 2024.
Article En | MEDLINE | ID: mdl-38713687

INTRODUCTION: Magnetic resonance-guided focused ultrasound (MRgFUS) has been demonstrated to be able to thermally ablate tendons with the aim to non-invasively disrupt tendon contractures in the clinical setting. However, the biomechanical changes of tendons permitting this disrupting is poorly understood. We aim to obtain a dose-dependent biomechanical response of tendons following magnetic resonance-guided focused ultrasound (MRgFUS) thermal ablation. METHODS: Ex vivo porcine tendons (n = 72) were embedded in an agar phantom and randomly assigned to 12 groups based on MRgFUS treatment. The treatment time was 10, 20, or 30s, and the applied acoustic power was 25, 50, 75, or 100W. Following each MRgFUS treatment, tendons underwent biomechanical tensile testing on an Instron machine, which calculated stress-strain curves during tendon elongation. Rupture rate, maximum treatment temperature, Young's modulus and ultimate strength were analyzed for each treatment energy. RESULTS: The study revealed a dose-dependent response, with tendons rupturing in over 50% of cases when energy delivery exceeded 1000J and 100% disruption at energy levels beyond 2000J. The achieved temperatures during MRgFUS were directly proportional to energy delivery. The highest recorded temperature was 56.8°C ± 9.34 (3000J), while the lowest recorded temperate was 18.6°C ± 0.6 (control). The Young's modulus was highest in the control group (47.3 MPa ± 6.5) and lowest in the 3000J group (13.2 MPa ± 5.9). There was no statistically significant difference in ultimate strength between treatment groups. CONCLUSION: This study establishes crucial thresholds for reliable and repeatable disruption of tendons, laying the groundwork for future in vivo optimization. The findings prompt further exploration of MRgFUS as a non-invasive modality for tendon disruption, offering hope for improved outcomes in patients with musculotendinous contractures.


High-Intensity Focused Ultrasound Ablation , Tendons , Animals , Swine , Tendons/surgery , Tendons/physiology , Tendons/diagnostic imaging , Biomechanical Phenomena , High-Intensity Focused Ultrasound Ablation/methods , Magnetic Resonance Imaging/methods , Tensile Strength , Elastic Modulus
2.
Int J Hyperthermia ; 41(1): 2350759, 2024.
Article En | MEDLINE | ID: mdl-38719202

INTRODUCTION: Magnetic Resonance-guided Focused Ultrasound (MRgFUS) thermal ablation is an effective noninvasive ultrasonic therapy to disrupt in vivo porcine tendon but is prone to inducing skin burns. We evaluated the safety profile of a novel hybrid protocol that minimizes thermal spread by combining long-pulse focused ultrasound followed by thermal ablation. METHODS: In-vivo Achilles tendons (hybrid N = 15, thermal ablation alone N = 21) from 15 to 20 kg Yorkshire pigs were randomly assigned to 6 treatment groups in two studies. The first (N = 21) was ablation (600, 900, or 1200 J). The second (N = 15) was hybrid: pulsed FUS (13.5 MPa peak negative pressure) followed by ablation (600, 900, or 1200 J). Measurements of ankle range of motion, tendon temperature, thermal dose (240 CEM43), and assessment of skin burn were performed in both groups. RESULTS: Rupture was comparable between the two protocols: 1/5 (20%), 5/5 (100%) and 5/5 (100%) for hybrid protocol, compared to 2/7 (29%), 6/7 (86%) and 7/7 (100%) for the ablation-only protocol with energies of 600, 900, and 1200 J, respectively. The hybrid protocol produced lower maximum temperatures, smaller areas of thermal dose, fewer thermal injuries to the skin, and fewer full-thickness skin burns. The standard deviation for the area of thermal injury was also smaller for the hybrid protocol, suggesting greater predictability. CONCLUSION: This study demonstrated a hybrid MRgFUS protocol combining long-pulse FUS followed by thermal ablation to be noninferior and safer than an ablation-only protocol for extracorporeal in-vivo tendon rupture for future clinical application for noninvasive release of contracted tendon.


Magnetic Resonance Imaging , Animals , Swine , Magnetic Resonance Imaging/methods , High-Intensity Focused Ultrasound Ablation/methods , Tendons/diagnostic imaging , Ultrasonic Therapy/methods
3.
Bone Res ; 12(1): 27, 2024 May 07.
Article En | MEDLINE | ID: mdl-38714649

Tendon adhesion is a common complication after tendon injury with the development of accumulated fibrotic tissues without effective anti-fibrotic therapies, resulting in severe disability. Macrophages are widely recognized as a fibrotic trigger during peritendinous adhesion formation. However, different clusters of macrophages have various functions and receive multiple regulation, which are both still unknown. In our current study, multi-omics analysis including single-cell RNA sequencing and proteomics was performed on both human and mouse tendon adhesion tissue at different stages after tendon injury. The transcriptomes of over 74 000 human single cells were profiled. As results, we found that SPP1+ macrophages, RGCC+ endothelial cells, ACKR1+ endothelial cells and ADAM12+ fibroblasts participated in tendon adhesion formation. Interestingly, despite specific fibrotic clusters in tendon adhesion, FOLR2+ macrophages were identified as an antifibrotic cluster by in vitro experiments using human cells. Furthermore, ACKR1 was verified to regulate FOLR2+ macrophages migration at the injured peritendinous site by transplantation of bone marrow from Lysm-Cre;R26RtdTomato mice to lethally irradiated Ackr1-/- mice (Ackr1-/- chimeras; deficient in ACKR1) and control mice (WT chimeras). Compared with WT chimeras, the decline of FOLR2+ macrophages was also observed, indicating that ACKR1 was specifically involved in FOLR2+ macrophages migration. Taken together, our study not only characterized the fibrosis microenvironment landscape of tendon adhesion by multi-omics analysis, but also uncovered a novel antifibrotic cluster of macrophages and their origin. These results provide potential therapeutic targets against human tendon adhesion.


Cell Movement , Macrophages , Regeneration , Humans , Animals , Macrophages/metabolism , Mice , Tendons/metabolism , Tendons/pathology , Male , Mice, Inbred C57BL , Mice, Knockout , Tendon Injuries/pathology , Tendon Injuries/metabolism , Tendon Injuries/genetics , Proteomics , Female , Multiomics
4.
Sci Rep ; 14(1): 10425, 2024 05 07.
Article En | MEDLINE | ID: mdl-38714804

Tarsal joint illness is a frequent source of hind limb lameness due to the complex anatomy of the region and the presence of numerous bony and soft tissue structures. Proper lameness diagnosis aims to discover the structure provoking lameness. Ultrasonography documents valuable information of soft tissues and characterizes soft tissue injuries that have heretofore been difficult to obtain either noninvasively or via radiography. The objectives of the current study were to develop and describe a standardized ultrasonographic protocol for investigation of the tarsal region in donkeys. The donkey tarsal anatomy was investigated in 5 cadavers and the tarsi of 11 healthy lameness free adult donkeys were echographically investigated. The dorsal, plantar, lateral and medial aspects of the tarsal region were substantially evaluated at four anatomical landmarks in both the longitudinal and horizontal planes using a multi-frequency 5-12 MHz linear transducer. Sonoanatomy of the extensor and flexor tarsal tendons, collateral and plantar ligaments, and synovial pouches was delineated and described. Systematic echography of the tarsal region allowed accurate localization and thorough exploration of various soft tissues of clinical interest in the donkey tarsus. Sonograms provided in this study should serve as a reference database for tarsal ultrasonography in clinical circumstances.


Equidae , Ultrasonography , Animals , Equidae/anatomy & histology , Ultrasonography/methods , Ultrasonography/veterinary , Tarsus, Animal/diagnostic imaging , Tarsus, Animal/anatomy & histology , Tendons/diagnostic imaging , Tendons/anatomy & histology
5.
PeerJ ; 12: e17179, 2024.
Article En | MEDLINE | ID: mdl-38803578

Surgical intervention is a common option for the treatment of wrist joint arthritis and traumatic wrist injury. Whether this surgery is arthrodesis or a motion preserving procedure such as arthroplasty, wrist joint biomechanics are inevitably altered. To evaluate effects of surgery on parameters such as range of motion, efficiency and carpal kinematics, repeatable and controlled motion of cadaveric specimens is required. This study describes the development of a device that enables cadaveric wrist motion to be simulated before and after motion preserving surgery in a highly controlled manner. The simulator achieves joint motion through the application of predetermined displacements to the five major tendons of the wrist, and records tendon forces. A pilot experiment using six wrists aimed to evaluate its accuracy and reproducibility. Biplanar X-ray videoradiography (BPVR) and X-Ray Reconstruction of Moving Morphology (XROMM) were used to measure overall wrist angles before and after total wrist arthroplasty. The simulator was able to produce flexion, extension, radioulnar deviation, dart thrower's motion and circumduction within previously reported functional ranges of motion. Pre- and post-surgical wrist angles did not significantly differ. Intra-specimen motion trials were repeatable; root mean square errors between individual trials and average wrist angle and tendon force profiles were below 1° and 2 N respectively. Inter-specimen variation was higher, likely due to anatomical variation and lack of wrist position feedback. In conclusion, combining repeatable intra-specimen cadaveric motion simulation with BPVR and XROMM can be used to determine potential effects of motion preserving surgeries on wrist range of motion and biomechanics.


Cadaver , Range of Motion, Articular , Wrist Joint , Humans , Wrist Joint/surgery , Wrist Joint/diagnostic imaging , Wrist Joint/physiology , Wrist Joint/anatomy & histology , Biomechanical Phenomena , Radiography/methods , Male , Aged , Reproducibility of Results , Tendons/surgery , Tendons/diagnostic imaging , Tendons/physiology , Tendons/anatomy & histology , Female
6.
Biol Open ; 13(5)2024 May 15.
Article En | MEDLINE | ID: mdl-38780905

Skeletal muscles and the tendons that attach them to bone are structurally complex and deform non-uniformly during contraction. While these tissue deformations dictate force production during movement, our understanding of this behaviour is limited due to challenges in obtaining complete measures of the constituent structures. To address these challenges, we present an approach for simultaneously measuring muscle, fascicle, aponeurosis, and tendon behaviour using sonomicrometry. To evaluate this methodology, we conducted isometric and dynamic contractions in in situ rabbit medial gastrocnemius. We found comparable patterns of strain in the muscle belly, fascicle, aponeurosis, and tendon during the isometric trials to those published in the literature. For the dynamic contractions, we found that our measures using this method were consistent across all animals and aligned well with our theoretical understanding of muscle-tendon unit behaviour. Thus, this method provides a means to fully capture the complex behaviour of muscle-tendon units across contraction types.


Aponeurosis , Muscle Contraction , Muscle, Skeletal , Tendons , Tendons/physiology , Animals , Rabbits , Aponeurosis/physiology , Muscle, Skeletal/physiology , Muscle Contraction/physiology , Biomechanical Phenomena
7.
Ann Med ; 56(1): 2337871, 2024 Dec.
Article En | MEDLINE | ID: mdl-38738394

Tendons are fibroblastic structures that link muscle and bone. There are two kinds of tendon injuries, including acute and chronic. Each form of injury or deterioration can result in significant pain and loss of tendon function. The recovery of tendon damage is a complex and time-consuming recovery process. Depending on the anatomical location of the tendon tissue, the clinical outcomes are not the same. The healing of the wound process is divided into three stages that overlap: inflammation, proliferation, and tissue remodeling. Furthermore, the curing tendon has a high re-tear rate. Faced with the challenges, tendon injury management is still a clinical issue that must be resolved as soon as possible. Several newer directions and breakthroughs in tendon recovery have emerged in recent years. This article describes tendon injury and summarizes recent advances in tendon recovery, along with stem cell therapy, gene therapy, Platelet-rich plasma remedy, growth factors, drug treatment, and tissue engineering. Despite the recent fast-growing research in tendon recovery treatment, still, none of them translated to the clinical setting. This review provides a detailed overview of tendon injuries and potential preclinical approaches for treating tendon injuries.


Genetic Therapy , Tendon Injuries , Tissue Engineering , Wound Healing , Tendon Injuries/therapy , Tendon Injuries/physiopathology , Humans , Wound Healing/physiology , Animals , Tissue Engineering/methods , Genetic Therapy/methods , Platelet-Rich Plasma , Tendons , Stem Cell Transplantation/methods , Intercellular Signaling Peptides and Proteins/therapeutic use , Intercellular Signaling Peptides and Proteins/metabolism
8.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(5): 562-569, 2024 May 15.
Article Zh | MEDLINE | ID: mdl-38752242

Objective: To explore the early effectiveness and influence on cartilage of local injection of multimodal drug cocktail (MDC) during anterior cruciate ligament reconstruction (ACLR). Methods: Between February 2022 and August 2023, patients undergone arthroscopic ACLR using autologous hamstring tendons were selected as the study subjects. Among them, 90 patients met the selection criteria and were randomly divided into 3 groups ( n=30) according to the different injection drugs after ligament reconstruction. There was no significant difference in baseline data such as gender, age, body mass index, surgical side, disease duration, preoperative thigh circumference, and preoperative levels of tumor necrosis factor α (TNF-α), interleukin 6 (IL-6), IL-1, matrix metalloproteinase 3 (MMP-3), MMP-13, and aggrecan (ACAN) in synovial fluid between groups ( P>0.05). After the ligament reconstruction during operation, corresponding MDC (consisting of ropivacaine, tranexamic acid, and betamethasone in group A, and ropivacaine, betamethasone, and saline in group B) or saline (group C) were injected into the joint and tendon site, respectively. The length of hospital stay, postoperative tramadol injection volume, incidence of complications, degree of knee joint swelling and range of motion, visual analogue scale (VAS) score, International Knee Documentation Committee (IKDC) score, Lyshlom score, and Hospital for Special Surgery (HSS) score were recorded and compared between groups. The T2 * values in different cartilage regions were detected by MRI examination and the levels of TNF-α, IL-6, IL-1, MMP-3, MMP-13, and ACAN in synovial fluid were detected by ELISA method. Results: The patients in group A, B, and C were followed up (12.53±3.24), (13.14±2.87), and (12.82±3.32) months, respectively. All incisions healed by first intention. Compared with group C, group A and group B had shorter length of hospital stay, less tramadol injection volume, and lower incidence of complications, showing significant differences ( P<0.05); there was no significant difference between group A and group B ( P>0.05). The degree of knee swelling in group A was significantly less than that in group B and group C ( P<0.05), but there was no significant difference between group B and group C ( P>0.05). At 3, 6, 12, 24, and 48 hours after operation, VAS scores of group A and group B were significantly lower than those of group C ( P<0.05); at 72 hours after operation, there was no significant difference among the three groups ( P>0.05). At 3 days, 14 days, and 1 month after operation, the range of motion of knee joint in group A were significantly better than those in group C ( P<0.05), and there was no significant difference between the other groups ( P>0.05). At 1 month after operation, the IKDC score of group A and group B was significantly higher than that of group C ( P<0.05); there was no significant difference among the three groups at other time points ( P>0.05). There was no significant difference in Lyshlom score and HSS score among the three groups at each time point ( P>0.05). At 14 days after operation, the levels of IL-1 and IL-6 in the synovial fluid in groups A and B were significantly lower than those in group C ( P<0.05). There was no significant difference in the levels of TNF-α, MMP-3, MMP-13, and ACAN between groups A and B ( P>0.05). At 1 month after operation, there was no significant difference in the above indicators among the three groups ( P>0.05). At 3, 6, and 12 months after operation, there was no significant difference in the T2 * values of different cartilage regions among the three groups ( P>0.05). Conclusion: Injecting MDC (ropivacaine, tranexamic acid, betamethasone) into the joint and tendon site during ACLR can achieve good early effectiveness without significant impact on cartilage.


Anterior Cruciate Ligament Reconstruction , Betamethasone , Ropivacaine , Humans , Anterior Cruciate Ligament Reconstruction/methods , Ropivacaine/administration & dosage , Male , Betamethasone/administration & dosage , Female , Adult , Matrix Metalloproteinase 3/metabolism , Anesthetics, Local/administration & dosage , Arthroscopy , Anterior Cruciate Ligament Injuries/surgery , Aggrecans/metabolism , Matrix Metalloproteinase 13/metabolism , Anterior Cruciate Ligament/surgery , Treatment Outcome , Tendons/transplantation , Cartilage/metabolism , Tumor Necrosis Factor-alpha/metabolism
9.
Bull Hosp Jt Dis (2013) ; 82(2): 146-153, 2024 Jun.
Article En | MEDLINE | ID: mdl-38739663

Surgical management of the subscapularis tendon is critical to a successful outcome following anatomic total shoulder arthroplasty. However, the optimal surgical technique for adequate exposure of the glenohumeral joint while mini-mizing complications resulting from subscapularis tendon dysfunction continues to be controversial. Common surgical techniques for the management of the subscapularis tendon include tenotomy, peeling, sparing, and lesser tuberosity oste-otomy. Despite a number of published studies comparing these techniques, no consensus has been reached regarding optimal management. This article reviews the extensive literature on the biomechanical, radiologic, and clinical outcomes of each technique, including recently published comparison studies.


Arthroplasty, Replacement, Shoulder , Shoulder Joint , Humans , Arthroplasty, Replacement, Shoulder/methods , Arthroplasty, Replacement, Shoulder/adverse effects , Shoulder Joint/surgery , Shoulder Joint/physiopathology , Shoulder Joint/diagnostic imaging , Treatment Outcome , Biomechanical Phenomena , Tenotomy/methods , Recovery of Function , Tendons/surgery , Range of Motion, Articular
10.
ACS Biomater Sci Eng ; 10(5): 2659-2679, 2024 May 13.
Article En | MEDLINE | ID: mdl-38697939

Connective tissue attaches to bone across an insertion with spatial gradients in components, microstructure, and biomechanics. Due to regional stress concentrations between two mechanically dissimilar materials, the insertion is vulnerable to mechanical damage during joint movements and difficult to repair completely, which remains a significant clinical challenge. Despite interface stress concentrations, the native insertion physiologically functions as the effective load-transfer device between soft tissue and bone. This review summarizes tendon, ligament, and meniscus insertions cross-sectionally, which is novel in this field. Herein, the similarities and differences between the three kinds of insertions in terms of components, microstructure, and biomechanics are compared in great detail. This review begins with describing the basic components existing in the four zones (original soft tissue, uncalcified fibrocartilage, calcified fibrocartilage, and bone) of each kind of insertion, respectively. It then discusses the microstructure constructed from collagen, glycosaminoglycans (GAGs), minerals and others, which provides key support for the biomechanical properties and affects its physiological functions. Finally, the review continues by describing variations in mechanical properties at the millimeter, micrometer, and nanometer scale, which minimize stress concentrations and control stretch at the insertion. In summary, investigating the contrasts between the three has enlightening significance for future directions of repair strategies of insertion diseases and for bioinspired approaches to effective soft-hard interfaces and other tough and robust materials in medicine and engineering.


Tendons , Humans , Biomechanical Phenomena/physiology , Tendons/physiology , Tendons/anatomy & histology , Animals , Bone and Bones/physiology , Ligaments/physiology , Fibrocartilage/physiology , Fibrocartilage/chemistry , Fibrocartilage/metabolism , Collagen/chemistry , Collagen/metabolism , Stress, Mechanical
11.
Int J Mol Sci ; 25(9)2024 Apr 26.
Article En | MEDLINE | ID: mdl-38731971

Tendinopathy, characterized by inflammatory and degenerative changes, presents challenges in sports and medicine. In addressing the limitations of conservative management, this study focuses on developing tendon grafts using extrusion bioprinting with platelet-rich plasma (PRP)-infused hydrogels loaded with tendon cells. The objective is to understand paracrine interactions initiated by bioprinted tendon grafts in either inflamed or non-inflamed host tissues. PRP was utilized to functionalize methacrylate gelatin (GelMA), incorporating tendon cells for graft bioprinting. Bioinformatic analyses of overexpressed proteins, predictive of functional enrichment, revealed insights into PRP graft behavior in both non-inflamed and inflamed environments. PRP grafts activated inflammatory pathways, including Interleukin 17 (IL-17), neuroinflammation, Interleukin 33 (IL-33), and chemokine signaling. Interleukin 1 beta (IL-1b) in the graft environment triggered p38 mitogen-activated protein kinase (MAPK) signaling, nuclear factor kappa light chain enhancer of activated B cells (NF-kB) canonical pathway, and Vascular Endothelial Growth Factor (VEGF) signaling. Biological enrichment attributed to PRP grafts included cell chemotaxis, collagen turnover, cell migration, and angiogenesis. Acellular PRP grafts differed from nude grafts in promoting vessel length, vessel area, and junction density. Angiogenesis in cellular grafts was enhanced with newly synthesized Interleukin 8 (IL-8) in cooperation with IL-1b. In conclusion, paracrine signaling from PRP grafts, mediated by chemokine activities, influences cell migration, inflammation, and angiogenic status in host tissues. Under inflammatory conditions, newly synthesized IL-8 regulates vascularization in collaboration with PRP.


Bioprinting , Platelet-Rich Plasma , Tendons , Tendons/metabolism , Bioprinting/methods , Animals , Platelet-Rich Plasma/metabolism , Humans , Tissue Engineering/methods , Hydrogels/chemistry , Tissue Scaffolds/chemistry , Tendinopathy/metabolism , Tendinopathy/therapy , Tendinopathy/pathology
12.
Sensors (Basel) ; 24(9)2024 May 03.
Article En | MEDLINE | ID: mdl-38733030

This article presents a study on the neurobiological control of voluntary movements for anthropomorphic robotic systems. A corticospinal neural network model has been developed to control joint trajectories in multi-fingered robotic hands. The proposed neural network simulates cortical and spinal areas, as well as the connectivity between them, during the execution of voluntary movements similar to those performed by humans or monkeys. Furthermore, this neural connection allows for the interpretation of functional roles in the motor areas of the brain. The proposed neural control system is tested on the fingers of a robotic hand, which is driven by agonist-antagonist tendons and actuators designed to accurately emulate complex muscular functionality. The experimental results show that the corticospinal controller produces key properties of biological movement control, such as bell-shaped asymmetric velocity profiles and the ability to compensate for disturbances. Movements are dynamically compensated for through sensory feedback. Based on the experimental results, it is concluded that the proposed biologically inspired adaptive neural control system is robust, reliable, and adaptable to robotic platforms with diverse biomechanics and degrees of freedom. The corticospinal network successfully integrates biological concepts with engineering control theory for the generation of functional movement. This research significantly contributes to improving our understanding of neuromotor control in both animals and humans, thus paving the way towards a new frontier in the field of neurobiological control of anthropomorphic robotic systems.


Hand , Neural Networks, Computer , Robotics , Tendons , Humans , Robotics/methods , Hand/physiology , Tendons/physiology , Movement/physiology , Nerve Net/physiology , Biomechanical Phenomena/physiology , Pyramidal Tracts/physiology , Animals
13.
Biomed Mater ; 19(4)2024 May 21.
Article En | MEDLINE | ID: mdl-38729187

Bundles of engineered collagen microfibers are promising synthetic tendons as substitutes for autogenous grafts. The purpose of this study was to develop high-speed and continuous spinning of collagen microfibers that involves stretching of collagen stream. Our study revealed the 'critical fibrillogenesis concentration (CFC)' of neutralized collagen solutions, which is defined as the upper limit of the collagen concentration at which neutralized collagen molecules remain stable as long as they are cooled (⩽10 °C). Neutralized collagen solutions at collagen concentrations slightly below the CFC formed cord-like collagen gels comprising longitudinally aligned fibrils when extruded from nozzles into an ethanol bath. Dry collagen microfibers with a controlled diameter ranging from 122 ± 2-31.2 ± 1.7 µm can be spun from the cord-like gels using nozzles of various sizes. The spinning process was improved by including stretching of collagen stream to further reduce diameter and increase linear velocity. We extruded a collagen solution through a 182 µm diameter nozzle while simultaneously stretching it in an ethanol bath during gelation and fiber formation. This process resembles the stretching of a melted thermoplastic resin because it solidifies during melt spinning. The mechanical properties of the stretched collagen microfibers were comparable to the highest literature values obtained using microfluidic wet spinning, as they exhibited longitudinally aligned fibrils both on their surface and in their core. Previous wet spinning methods were unable to generate collagen microfibers with a consistent tendon-like fibrillar arrangement throughout the samples. Although the tangent modulus (137 ± 7 MPa) and stress at break of the swollen bundles of stretched microfibers (13.8 ± 1.9 MPa) were lower than those of human anterior cruciate ligament, they were within the same order of magnitude. We developed a spinning technique that produces narrow collagen microfibers with a tendon-like arrangement that can serve as artificial fiber units for collagen-based synthetic tendons.


Collagen , Materials Testing , Tendons , Tissue Engineering , Collagen/chemistry , Tissue Engineering/methods , Animals , Biocompatible Materials/chemistry , Humans , Tensile Strength , Stress, Mechanical , Tissue Scaffolds/chemistry
14.
BMC Musculoskelet Disord ; 25(1): 408, 2024 May 23.
Article En | MEDLINE | ID: mdl-38783272

BACKGROUND: Tenodesis of the long head of the biceps tendon is frequently performed in shoulder surgery, and all-suture anchors have become more popular as fixation methods. However, uncertainty still exists regarding the ultimate load to failure of all-suture anchors and the best insertion angle at a cortical humeral insertion point. PURPOSE: The purpose of this study was to compare the biomechanical characteristics of three types of all-suture anchors frequently used for biceps tenodesis. In addition, the influence of two different insertion angles was observed in a porcine humeri model. METHODS: The ultimate load to failure and failure mode of three types of all-suture anchors (1.6 FiberTak®, 1.9 FiberTak®, 2.6 FiberTak®, Arthrex®) applicable for subpectoral biceps tenodesis were evaluated at 90° and 45° insertion angles in 12 fresh-frozen porcine humeri. The anchors were inserted equally alternated in a randomized manner at three different insertion sites along the bicipital groove, and the suture tapes were knotted around a rod for pullout testing. In total, 36 anchors were evaluated in a universal testing machine (Zwick & Roell). RESULTS: The 2.6 FiberTak® shows higher ultimate loads to failure with a 90° insertion angle (944.0 N ± 169.7 N; 537.0 N ± 308.8 N) compared to the 1.9 FiberTak® (677.8 N ± 57.7 N; 426.3 N ± 167.0 N, p-value: 0.0080) and 1.6 FiberTak® (733.0 N ± 67.6 N; 450.0 N ± 155.8 N, p-value: 0.0018). All anchor types show significantly higher ultimate loads to failure and smaller standard deviations at the 90° insertion angle than at the 45° insertion angle. The major failure mode was anchor pullout. Only the 2.6 FiberTak® anchors showed suture breakage as the major failure mode when placed with a 90° insertion angle. CONCLUSIONS: All three all-suture anchors are suitable fixation methods for subpectoral biceps tenodesis. Regarding our data, we recommend 90° as the optimum insertion angle. CLINICAL RELEVANCE: The influence of anchor size and insertion angle of an all-suture anchor should be known by the surgeon for optimizing ultimate loads to failure and for achieving a secure fixation.


Suture Anchors , Tenodesis , Animals , Tenodesis/methods , Tenodesis/instrumentation , Swine , Biomechanical Phenomena , Materials Testing , Muscle, Skeletal/surgery , Muscle, Skeletal/physiopathology , Tendons/surgery , Tendons/physiopathology , Models, Animal , Weight-Bearing
15.
Musculoskelet Surg ; 108(2): 153-162, 2024 Jun.
Article En | MEDLINE | ID: mdl-38713360

PURPOSE: It is unclear which triceps tendon repair constructs and techniques produce the strongest biomechanical performance while minimizing the risk of gap formation and repair failure. We aimed to determine associations of construct and technique variables with the biomechanical strength of triceps tendon repairs. PubMed, Embase, Cochrane Library, Web of Science, Scopus, and ClinicalTrials.gov were systematically searched for peer-reviewed studies on biomechanical strength of triceps tendon repairs in human cadavers. 6 articles met the search criteria. Meta-regression was performed on the pooled dataset (123 specimens). Outcomes of interest included gap formation, failure mode, and ultimate failure load. Covariates were fixation type; number of implants; and number of sutures. Stratification by covariates was performed. We found no association between fixation type and ultimate failure load; however, suture anchor fixation was associated with less gap formation compared with transosseous direct repair (ß = - 1.1; 95% confidence interval [CI]:- 2.2, - 0.04). A greater number of implants was associated with smaller gap formation (ß = - 0.77; 95% CI: - 1.3, - 0.28) while a greater number of sutures was associated with higher ultimate failure load ( ß= 3; 95% CI: 21, 125). In human cadaveric models, the number of sutures used in triceps tendon repairs may be more important than the fixation type or number of implants for overall strength. If using a transosseous direct repair approach to repair triceps tendon tears, surgeons may choose to use more sutures in their repair in order to balance the risk of larger gap formation when compared to indirect repair techniques. LEVEL OF EVIDENCE: Level III.


Cadaver , Suture Techniques , Tendon Injuries , Humans , Biomechanical Phenomena , Tendon Injuries/surgery , Tendons/surgery , Suture Anchors
16.
BMC Med Genomics ; 17(1): 122, 2024 May 06.
Article En | MEDLINE | ID: mdl-38711057

OBJECTIVE: There is increasing evidence that type 2 diabetes mellitus (T2DM) is an independent risk factor for the occur of tendinopathy. Therefore, this study is the first to explore the dynamic changes of the "gene profile" of supraspinatus tendon in rats at different time points after T2DM induction through transcriptomics, providing potential molecular markers for exploring the pathogenesis of diabetic tendinopathy. METHODS: A total of 40 Sprague-Dawley rats were randomly divided into normal (NG, n = 10) and T2DM groups (T2DM, n = 30) and subdivided into three groups according to the duration of diabetes: T2DM-4w, T2DM-8w, and T2DM-12w groups; the duration was calculated from the time point of T2DM rat model establishment. The three comparison groups were set up in this study, T2DM-4w group vs. NG, T2DM-8w group vs. NG, and T2DM-12w group vs. NG. Differentially expressed genes (DEGs) in 3 comparison groups were screened. The intersection of the three comparison groups' DEGs was defined as key genes that changed consistently in the supraspinatus tendon after diabetes induction. Cluster analysis, gene ontology (GO) functional annotation analysis and Kyoto encyclopedia of genes and genomes (KEGG) functional annotation and enrichment analysis were performed for DEGs. RESULTS: T2DM-4w group vs. NG, T2DM-8w group vs. NG, and T2DM-12w group vs. NG detected 519 (251 up-regulated and 268 down-regulated), 459 (342 up-regulated and 117 down-regulated) and 328 (255 up-regulated and 73 down-regulated) DEGs, respectively. 103 key genes of sustained changes in the supraspinatus tendon following induction of diabetes, which are the first identified biomarkers of the supraspinatus tendon as it progresses through the course of diabetes.The GO analysis results showed that the most significant enrichment in biological processes was calcium ion transmembrane import into cytosol (3 DEGs). The most significant enrichment in cellular component was extracellular matrix (9 DEGs). The most significant enrichment in molecular function was glutamate-gated calcium ion channel activity (3 DEGs). The results of KEGG pathway enrichment analysis showed that there were 17 major pathways (p < 0.05) that diabetes affected supratinusculus tendinopathy, including cAMP signaling pathway and Calcium signaling pathway. CONCLUSIONS: Transcriptomics reveals dynamic changes in the"gene profiles"of rat supraspinatus tendon at three different time points after diabetes induction. The 103 DEGs identified in this study may provide potential molecular markers for exploring the pathogenesis of diabetic tendinopathy, and the 17 major pathways enriched in KEGG may provide new ideas for exploring the pathogenesis of diabetic tendinopathy.


Diabetes Mellitus, Experimental , Diabetes Mellitus, Type 2 , Rats, Sprague-Dawley , Animals , Rats , Diabetes Mellitus, Experimental/genetics , Diabetes Mellitus, Experimental/metabolism , Diabetes Mellitus, Type 2/genetics , Diabetes Mellitus, Type 2/metabolism , Male , Gene Expression Profiling , Transcriptome , Time Factors , Tendons/metabolism , Tendons/pathology , Rotator Cuff/pathology , Rotator Cuff/metabolism
17.
FASEB J ; 38(10): e23629, 2024 May 31.
Article En | MEDLINE | ID: mdl-38742770

The molecular and cellular basis of health in human tendons remains poorly understood. Among human tendons, hamstring tendon has markedly low pathology and can provide a prototypic healthy tendon reference. The aim of this study was to determine the transcriptomes and location of all cell types in healthy hamstring tendon. Using single nucleus RNA sequencing, we profiled the transcriptomes of 10 533 nuclei from four healthy donors and identified 12 distinct cell types. We confirmed the presence of two fibroblast cell types, endothelial cells, mural cells, and immune cells, and identified cell types previously unreported in tendons, including different skeletal muscle cell types, satellite cells, adipocytes, and undefined nervous system cells. The location of these cell types within tendon was defined using spatial transcriptomics and imaging, and potential transcriptional networks and cell-cell interactions were analyzed. We demonstrate that fibroblasts have the highest number of potential cell-cell interactions in our dataset, are present throughout the tendon, and play an important role in the production and organization of extracellular matrix, thus confirming their role as key regulators of hamstring tendon homeostasis. Overall, our findings underscore the complexity of the cellular networks that underpin healthy human tendon function and the central role of fibroblasts as key regulators of hamstring tendon tissue homeostasis.


Gene Expression Profiling , Hamstring Tendons , Transcriptome , Humans , Male , Adult , Hamstring Tendons/metabolism , Fibroblasts/metabolism , Female , Cell Nucleus/metabolism , Cell Nucleus/genetics , Extracellular Matrix/metabolism , Tendons/metabolism
18.
J Biomech Eng ; 146(7)2024 Jul 01.
Article En | MEDLINE | ID: mdl-38584416

Aging is a primary risk factor for degenerative tendon injuries, yet the etiology and progression of this degeneration are poorly understood. While aged tendons have innate cellular differences that support a reduced ability to maintain mechanical tissue homeostasis, the response of aged tendons to altered levels of mechanical loading has not yet been studied. To address this question, we subjected young and aged murine flexor tendon explants to various levels of in vitro tensile strain. We first compared the effect of static and cyclic strain on matrix remodeling in young tendons, finding that cyclic strain is optimal for studying remodeling in vitro. We then investigated the remodeling response of young and aged tendon explants after 7 days of varied mechanical stimulus (stress deprivation, 1%, 3%, 5%, or 7% cyclic strain) via assessment of tissue composition, biosynthetic capacity, and degradation profiles. We hypothesized that aged tendons would show muted adaptive responses to changes in tensile strain and exhibit a shifted mechanical setpoint, at which the remodeling balance is optimal. Interestingly, we found that 1% cyclic strain best maintains native physiology while promoting extracellular matrix (ECM) turnover for both age groups. However, aged tendons display fewer strain-dependent changes, suggesting a reduced ability to adapt to altered levels of mechanical loading. This work has a significant impact on understanding the regulation of tissue homeostasis in aged tendons, which can inform clinical rehabilitation strategies for treating elderly patients.


Tendon Injuries , Tendons , Humans , Mice , Animals , Aged , Stress, Mechanical , Tendons/physiology , Extracellular Matrix , Aging
19.
JBJS Case Connect ; 14(2)2024 Apr 01.
Article En | MEDLINE | ID: mdl-38669445

CASE: A 22-year-old man and a 14-year-old adolescent boy, who exhibited moderate general joint laxity, experienced recurrent sternoclavicular joint instability without traumatic events. The patients were successfully treated with extra-articular stabilization using autologous tendon grafts without surgical exposure of the sternoclavicular joint. CONCLUSION: Atraumatic instability of the sternoclavicular joint is rare but often results in recurrent instability accompanied by discomfort, pain, and limitations in activities. Extra-articular stabilization, which reinforces the anterior capsule of the sternoclavicular joint and prevents anterior displacement of the proximal clavicle at the elevated arm position, could be a viable surgical option for this pathological condition.


Joint Instability , Sternoclavicular Joint , Humans , Sternoclavicular Joint/surgery , Sternoclavicular Joint/diagnostic imaging , Male , Joint Instability/surgery , Adolescent , Young Adult , Recurrence , Tendons/surgery , Tendons/transplantation
20.
J Strength Cond Res ; 38(6): 1041-1047, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38595295

ABSTRACT: Sasajima, S and Kubo, K. Effect of static stretching on tendon hysteresis and efficiency during repetitive jumping. J Strength Cond Res 38(6): 1041-1047, 2024-To date, no studies have experimentally shown a relationship between tendon hysteresis and exercise efficiency. However, previous studies showed that tendon hysteresis decreased immediately after static stretching. The purposes of this study were to (a) investigate the change in tendon hysteresis during the recovery period after static stretching and (b) determine whether exercise efficiency is enhanced because of the decline of tendon hysteresis after static stretching. For stretching (1 minute × 4 sets) and control conditions, tendon hysteresis was measured during ramp (i.e., lower strain rate of tendon) and ballistic (i.e., higher strain rate of tendon) contractions before, immediately, 15, 30, 45, and 60 minutes after interventions. In addition, electromyograms of the plantar flexor muscles (medial gastrocnemius [MG], lateral gastrocnemius [LG], and soleus muscles [SOL]) and oxygen consumption (V̇O 2 ) were measured during 10 minutes of submaximal repetitive jumping after both interventions. Tendon hysteresis (during ramp and ballistic contractions) reduced by static stretching persisted for up to 60 minutes (effect of time p < 0.001). During repetitive jumping, no differences in electromyograms of the plantar flexor muscles (effect of condition p = 0.786 for MG, p = 0.124 for LG, p = 0.682 for SOL) or V̇O 2 (effect of condition p = 0.534) were found between stretching and control conditions. These results suggest that the reduction in tendon hysteresis because of static stretching continues until 60 minutes after the end of stretching, and static stretching does not change the efficiency (evaluated by electromyograms of the plantar flexor muscles and V̇O 2 ) during submaximal repetitive jumping.


Electromyography , Muscle Stretching Exercises , Muscle, Skeletal , Oxygen Consumption , Tendons , Humans , Muscle Stretching Exercises/physiology , Male , Young Adult , Tendons/physiology , Muscle, Skeletal/physiology , Oxygen Consumption/physiology , Adult , Biomechanical Phenomena , Plyometric Exercise , Muscle Contraction/physiology
...