Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Surg Endosc ; 36(6): 4624-4630, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35102429

RESUMO

BACKGROUND: Difficulties in establishing diagnosis of small bowel (SB) disorders, prevented their effective treatment. This problem was largely resolved by wireless capsule endoscopy (WCE), which has since become the first line investigation for suspected SB disorders. Several types of WCE pills are now used in clinical practice, despite their limitations and complications. WCE pills are large, rigid and immotile capsules. When swallowed, they provide SB enteroscopy downloaded to a data logger carried by the patient. Most of the complications of WCEs result from lack of intrinsic locomotion: incomplete examination, capsule retention and impaction within strictures. In addition, the rigid nature and size of current generation of WCE pills is accompanied by 0.1% inability to swallow the pill by patients with normal esophageal motility. METHODS: The aim of this communication is to describe the initial prototype, P1, which is thinner and slightly longer than the current generation of WCEs. In addition, it exhibits intrinsic active locomotion, produced by vibrating silicon legs. These generate a controlled-skid locomotion on the small bowel mucosal surface, rendered slippery by surface mucus and intraluminal surfactant bile salts. We demonstrate the mechanism responsible for the active locomotion of P1, which we consider translatable into a working prototype, suitable for further R&D for eventual clinical translation. RESULTS: The shape and attachment of the rubber vibrating legs to vibrating actuators, have been designed specifically to produce a tight clockwise circular motion. When inserted inside a circular tube in vitro of equivalent diameter to human small intestine, the intrinsic circular clockwise motion of P1 translates into a linear locomotion by the constraints imposed by the surrounding circular walls of SB and rest of the gastrointestinal tract. This design ensures device stability during transit, essential for imaging and targeting lesions encountered during the enteroscopy. We preformed two experiments: (i) transit of P1 through a phantom consisting of a segment of PVC tube placed on a horizontal surface and (ii) transit through a transparent slippery nylon sleeve insufflated with air. In the PVC tube, its transit rate averages 15.6 mm/s, which is too fast for endoscopy: whereas inside the very slippery nylon sleeve insufflated with air, the average transit rate of P1 is reduced to 5.9 mm/s, i.e., ideal for inspection endoscopy. CONCLUSIONS: These in-vitro experiments indicate that the P1 hybrid soft robot prototype has the potential specifically for clinical translation for SB enteroscopy.


Assuntos
Endoscopia por Cápsula , Enteropatias , Robótica , Humanos , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/patologia , Nylons , Cloreto de Polivinila
2.
Surgeon ; 20(6): 351-355, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34840066

RESUMO

BACKGROUND: Patients with advanced illnesses are often admitted with acute surgical emergencies. There is currently no evidence characterising such admissions. We aimed to evaluate emergency patients, managed non-operatively, who died during the same admission. METHODS: This single-centre retrospective, observational study collected data points for a 12 month period including age, prior documented do not resuscitate order (DNAR), existing cancer, Charlson Comorbidity Index, frailty, surgical diagnosis, interval from admission to death and care given. Patients who underwent surgical intervention were excluded. Non-parametric tests were used for statistical analysis. RESULTS: A total of 72 patients were included in this study, of which 68.1% died within 6 days of admission (median 4.0 days). Patients with visceral perforation, obstruction, bowel ischaemia or known malignancy were more likely to die within 6 days than those with pancreatitis, sepsis or new malignancy (median 2 vs 7 days, p < 0.001). Patients with frailty (2 vs 4 days, p = 0.017) and existing DNAR (3 vs 4 days, p = 0.048) died more rapidly than those without. Age and comorbidity index did not impact time to death. CONCLUSION: Frailty, surgical diagnosis and existing DNAR were predictors of shorter admission to death interval, while age and comorbidity index were not. This has implications on inpatient palliative care service planning.


Assuntos
Fragilidade , Humanos , Estudos Retrospectivos , Hospitalização , Morte , Hospitais
3.
Scott Med J ; 65(4): 144-148, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32878574

RESUMO

BACKGROUND AND AIM: COVID-19 pandemic has predisposed patients undergoing surgery to post-operative infection and resultant complications. Appendicitis is frequently managed by appendicectomy. After the onset of the pandemic, selected cases of appendicitis were managed with antibiotics which is a recognised treatment option. Our objective was to compare the management of appendicitis and post-operative outcomes between pre- and post-COVID-19. METHODS: Ninety-six patients were identified from before the onset of the pandemic (November 2019) to after the onset of the pandemic (May 2020). Data were collected retrospectively from electronic records including demographics, investigations, treatment, duration of inpatient stay, complications, readmissions and compared between pre- and post-COVID-19 groups. RESULTS: One hundred percent underwent surgical treatment before the onset of pandemic, compared with 56.3% from the onset of the pandemic. A greater percentage of patients were investigated with imaging post-COVID-19 (100% versus 60.9%; p < 0.00001). There was no significant difference in the outcomes between the two groups. CONCLUSION: CT/MRI scan was preferred to laparoscopy in diagnosing appendicitis and conservative management of uncomplicated appendicitis was common practice after the onset of pandemic. Health boards can adapt their management of surgical conditions during pandemics without adverse short-term consequences. Long term follow-up of this cohort will identify patients suitable for conservative management.


Assuntos
Apendicectomia , Apendicite/diagnóstico , Apendicite/cirurgia , Betacoronavirus , Infecções por Coronavirus/epidemiologia , Pneumonia Viral/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , COVID-19 , Infecções por Coronavirus/prevenção & controle , Infecções por Coronavirus/transmissão , Feminino , Humanos , Laparoscopia , Masculino , Pessoa de Meia-Idade , Pandemias/prevenção & controle , Seleção de Pacientes , Pneumonia Viral/prevenção & controle , Pneumonia Viral/transmissão , Complicações Pós-Operatórias/epidemiologia , Padrões de Prática Médica , Estudos Retrospectivos , SARS-CoV-2 , Adulto Jovem
4.
BMC Med Educ ; 20(1): 70, 2020 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-32143709

RESUMO

BACKGROUND: The objectives of this study were to investigate the relationship between the acquisition of laparoscopic suturing skills and other operative laparoscopic skills and to provide evidence to determine ideal time and duration to introduce laparoscopic suturing training. METHODS: The first part of the study explored the relationship between the acquisition of laparoscopic suturing skills and proficiency of other operative laparoscopic skills. The second part of the study consisted of an opinion survey from senior and junior trainees on aspects of training in laparoscopic suturing. RESULTS: One hundred twenty-eight surgical trainees participated in this study. The total scores of task performance of 57 senior surgical trainees in laparoscopic suturing skills consisting of needle manipulation and intracoporeal knot tying were improved significantly after the training course (46.9 ± 5.3 vs 29.5 ± 9.4, P < .001), the improvement rate was 59%. No statistically significant correlations were observed between intracorporeal laparoscopic suturing skills and proficiency in the basic laparoscopic manipulative skills assessed before (r = 0.193; P = 0.149) and after (r = 0.024; P = 0.857) the training course. 91% of senior trainees and 94% junior trainees expressed that intracorporeal suturing should be introduced at an early stage of the training curriculum. CONCLUSIONS: There was no statistically significant correlation between the performance on basic operative laparoscopic skills (non-suturing skills) and laparoscopic suturing skills observed in this study. The acquisition of basic laparoscopic skills is not a prerequisite for training in intracorporeal suturing and it may be beneficial for the surgical trainees to learn this skill early in the surgical training curriculum. Surgical trainees want to learn and practice laparoscopic suturing earlier than later in their training.


Assuntos
Competência Clínica , Currículo , Técnicas de Sutura/educação , Adulto , Avaliação Educacional , Feminino , Humanos , Internato e Residência , Laparoscopia/educação , Masculino , Inquéritos e Questionários , Análise e Desempenho de Tarefas
5.
Am J Surg ; 216(6): 1114-1117, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30093093

RESUMO

AIM: There are reports of visual strains and associated symptoms when operating in a 3D laparoscopic environment. We aimed to study the extent of visual symptoms seen in 3D versus conventional 2D imaging in volunteers performing laparoscopic tasks and study the effect of eye exercises on 3D laparoscopy. METHODS: Twenty four consented laparoscopic novices were required to undergo a visual acuity test (Snellen chart) and eye deviation test (Maddox Wing). A battery of specific isolated laparoscopic tasks lasting 30 min was developed to test their ability to detect changes in 2D and 3D environments separately. Before and after the 2D and 3D laparoscopic tasks, subjects were asked to complete a standardised questionnaire designed to scale (from 0 to 10) their visual symptoms (blurred vision, difficulty in refocusing from one distance to another, irritated or burning eyes, dry eyes, eyestrain, headache and dizziness). Participants who underwent 3D laparoscopic tasks were randomized into two groups, those who received two minutes eye exercises before performing the tasks and those who didn't. Independent t-test was used for the statistical analysis of this study. RESULTS: Visual symptoms and eye strain were significant in 2D (p < 0.01) and difficulty in refocusing from one distance to another was significant in 3D laparoscopic imaging (p < 0.05). There was no significant effect of the simple eye exercises on relieving the visual symptoms in the 3D group. CONCLUSION: Visual symptoms were present in both 2D and 3D imaging laparoscopy. Eye strain was prominent in 2D imaging, while difficulty in refocusing from one distance to another was prominent in 3D. Eye exercises for 3D visual symptoms did not bring any significant improvement.


Assuntos
Imageamento Tridimensional/efeitos adversos , Laparoscopia/efeitos adversos , Transtornos da Visão/etiologia , Acuidade Visual , Competência Clínica , Humanos , Laparoscopia/educação , Treinamento por Simulação , Análise e Desempenho de Tarefas
6.
World J Surg ; 42(6): 1695-1700, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29143094

RESUMO

INTRODUCTION: Surgical checklists are in use to reduce errors for safer surgery. We aimed to study the effect of a previously designed performance-based self-administered intra-procedural checklist on the performance of trainees during elective laparoscopic cholecystectomy. METHODS: Twenty-four laparoscopic cholecystectomies were enrolled into the study. Six surgical trainees each performed four procedures, two without the checklist and directly followed by two procedures with the checklist. A soft beeping sound reminded each trainee to apply the checklist every 4 min during the procedures. The unedited videos were analysed using the human reliability analysis technique for the number of consequential errors, number of interventions by the trainer, number of instrument movements and time execution. The trainees' satisfaction was assessed on a 5-point Likert scale questionnaire. Nonparametric test was used for data analysis. p value was defined as significant when p < 0.05. RESULTS: Participants performed statistically better with the application of the checklist compared to when no checklist was used, respectively: Median [IQR] total number of errors 1.51 [0.80] versus 3.84 [1.42] (p = 0.002) and consequential errors 0.20 [0.12] versus 0.45 [0.42] (p = 0.005), and the number of instrument movements per time decreased from 11.90 [5.34] to 10.38 [5.16] (p = 0.04). With the introduction of the checklist, the number of interventions by the trainer per time decreased from 2.79 [1.85] to 0.43 [1.208] (p = 0.003). The trainees satisfaction score was 4.5 [1] for the first question, 4 [1] for the second question and 4 [2] for the third question. CONCLUSION: The self-administered intra-procedural checklist improved the performance of surgical trainees and decreased the number of interventions by the trainer during laparoscopic cholecystectomy. The trainees were generally satisfied using the checklist during the procedures.


Assuntos
Lista de Checagem/normas , Colecistectomia Laparoscópica/educação , Colecistectomia Laparoscópica/normas , Internato e Residência/normas , Programas de Autoavaliação , Competência Clínica , Procedimentos Cirúrgicos Eletivos/educação , Procedimentos Cirúrgicos Eletivos/normas , Feminino , Humanos , Masculino , Projetos Piloto , Reprodutibilidade dos Testes , Inquéritos e Questionários
7.
World J Surg ; 42(3): 688-694, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28936629

RESUMO

AIMS: There is a strong evidence to suggest that 3D imaging improves the laparoscopic task performance when compared against 2D. However, to date, no study has explained why that might be. We identified six generic visual components during laparoscopic imaging and aimed to study each component in both 2D and 3D environments for comparison. METHODS: Twenty-four consented laparoscopic novices performed specific isolated tasks in a laparoscopic Endo Trainer in 2D and 3D separately. The six endpoints were the accuracy in detecting changes in the laparoscopic images in the following components: distance, area, angle, curvature, volume and spatial coordinates. All the components except the spatial coordinates were assessed by creation, measurement and comparison. Each component was analysed between 2D and 3D groups and within each group at different values. Tests of spatial coordinates were video-recorded and analysed for error number and error types by human reliability analysis technique. Errors types included past-pointing, not reaching the object and touching the wrong object. The results were statistically analysed with independent T test. RESULTS: There was no statistically significant difference between 2D and 3D accuracy in the angle, area, distance and curvature. 3D performed more accurately in comparing volumes (p = 0.05). In spatial coordinates, there were a statistically significant higher number of errors in 2D as compared to 3D (p < 0.001). Past-pointing and touching the wrong objects were significantly higher in 2D (p < 0.05). CONCLUSION: Between all the visual components, detecting change in volume and the spatial coordinates showed significant improvement in 3D environment when compared to 2D.


Assuntos
Imageamento Tridimensional , Laparoscopia , Análise e Desempenho de Tarefas , Humanos , Laparoscopia/métodos , Distribuição Aleatória , Processamento Espacial , Gravação em Vídeo
8.
J Surg Res ; 219: 232-237, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-29078887

RESUMO

BACKGROUND: A number of tools for assessing task performance of the laparoscopic camera assistant have been described, but few focus on the acquisition and assessment of the attainment of proficiency in novice laparoscopic camera assistants. Our aim was to develop a simulated objective assessment tool for a novice camera assistant. MATERIALS AND METHODS: A 10-cycle image navigation task tool was developed. This involved a series of 360° clockwise and anticlockwise rotation maneuvers of a 30° laparoscope along its shaft, focusing on a predefined geometric target on a 45° fixed slope in a laparoscopic box trainer. The tasks were to simultaneously maintain neutral horizon, optimum distance, and centering. Task accuracy and time to completion were assessed objectively at 3-s intervals on an unedited video recording. RESULTS: Twenty-nine novice medical students were assessed. Novices improved mean total error and task completion time (first versus fifth cycle, mean errors 15.4 versus 8.4, P = 0.048; mean task time 158.1 versus 92.9 s, P = 0.04). This improvement continued until the task cycle was completed (sixth versus 10th cycles, 7.9 versus 6.2, P = 0.01; 91.9 versus 76.6 s, P < 0.0001). There was a significant decrease in centering errors (5.2 versus 2.4, P = 0.001) and horizon (4.8 versus 2.3, P = 0.004), when comparing the first versus fifth task cycle. It took six cycles for optimum distance to achieve significance (5.4 versus 3.3, P = 0.023). CONCLUSIONS: Using our assessment tool, novices achieved an objective proficiency-gain curve for laparoscopic camera navigation tasks. There was improvement in errors related to maintaining horizon, optimum distance, and centering. Mean task completion time also decreased. This tool could be used as an additional mean of assessment and training in novice surgical trainees.


Assuntos
Laparoscopia/educação , Análise e Desempenho de Tarefas , Humanos
10.
Surgeon ; 15(2): 98-103, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27426914

RESUMO

INTRODUCTION: The positive effect of feedback has long been recognized in surgical education. Surgical educators convey feedback to improve the performance of the surgical trainees. We aimed to review the scientific classification and application of feedback in surgical education, and to propose possible future directions for research. METHODS: A literature search was performed using Pubmed, OVID, CINAHL, Web of science, EMBASE, ERIC database and Google Scholar. The following search terms were used: 'feedback', 'feedback in medical education', 'feedback in medical training' and 'feedback in surgery'. The search was limited to articles in English. RESULTS: From 1157 citations, 12 books and 43 articles met the inclusion criteria and were selected for this review. CONCLUSION: Feedback comes in a variety of types and is an essential tool for learning and developing performance in surgical education. Different methods of feedback application are evolving and future work needs to concentrate on the value of each method as well as the role of new technologies in surgical education.


Assuntos
Educação Médica , Feedback Formativo , Cirurgia Geral/educação , Humanos
11.
Surg Endosc ; 31(5): 2242-2246, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27585470

RESUMO

Surgical checklists are in use as means to reduce errors. Checklists are infrequently applied during emergency situations in surgery. We aimed to study the effect of a simple self-administered performance-based checklist on the laparoscopic task when applied during an emergency-simulated scenario. The aviation checklist for unexpected situations is commonly used for simulated training of pilots to handle emergency during flights. This checklist was adopted for use as a standardised-performance-based checklist during emergency surgical tasks. Thirty consented laparoscopic novices were exposed unexpectedly to a bleeding vessel in a laparoscopic virtual reality simulator as an emergency scenario. The task consisted of using laparoscopic clips to achieve haemostasis. Subjects were randomly allocated into two equal groups; those using the checklist that was applied once every 20 s (checklist group) and those without (control group). The checklist group performed significantly better in 5 out of 7 technical factors when compared to the control group: right instrument path length (m), median (IQR) 1.44 [1.22] versus 2.06 [1.70] (p = 0.029), right instrument angular path (degree) 312.10 (269.44 versus 541.80 [455.16] (p = 0.014), left instrument path length (m) 1.20 [0.60] versus 2.08 [2.02] (p = 0.004), and left instrument angular path (degree) 277.62 [132.11] versus 385.88 [428.42] (p = 0.017). The checklist group committed significantly fewer number of errors in the application of haemostatic clips, 3 versus 28 (p = 0.006). Although statistically not significant, total blood loss (lit) decreased in the checklist group from 0.83 [1.23] to 0.78 [0.28] (p = 0.724) and total time (sec) from 186.51 [145.69] to 125.14 [101.46] (p = 0.165). The performance-based intra-procedural checklist significantly enhanced the surgical task performance of novices in an emergency-simulated scenario.


Assuntos
Lista de Checagem/normas , Competência Clínica , Educação Médica Continuada/métodos , Tratamento de Emergência/métodos , Laparoscopia/educação , Erros Médicos/prevenção & controle , Adulto , Feminino , Humanos , Laparoscopia/métodos , Masculino , Análise e Desempenho de Tarefas , Interface Usuário-Computador
13.
Am J Surg ; 214(2): 373-377, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27773378

RESUMO

BACKGROUND: Surgical checklists are used for error reduction. Checklists are infrequently applied during procedures and have been limited to lists of procedural steps as aid memoires. We aimed to study the effect of a self-administered checklist on the laparoscopic task performance of novices during a standardized task. METHODS: Twenty novices were randomized into 2 equal groups, those receiving paper feedback (control group) and those receiving paper feedback and the checklist (checklist group). Subjects performed laparoscopic double knots, repeated over 5 separate stages. Human reliability assessment technique was used for error analysis. RESULTS: 2,341 errors were detected during the 5 stages. During the first stage, the errors were not significantly different between the 2 groups. The checklist group committed significantly fewer errors as compared with the control group during all the later 4 stages (P < .01). CONCLUSIONS: The simple intraprocedural checklist significantly improved the laparoscopic task performance and the learning curve of laparoscopic novices.


Assuntos
Lista de Checagem , Competência Clínica , Cuidados Intraoperatórios/normas , Laparoscopia/educação , Laparoscopia/normas , Feminino , Humanos , Masculino
14.
Am J Emerg Med ; 34(9): 1750-3, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27364645

RESUMO

BACKGROUND AND PURPOSE OF THE STUDY: There is growing evidence to suggest the use of urinary 5-hydroxyindoleacetic acid (5-HIAA) test to help with the diagnosis of appendicitis. The aim of our study was to establish whether urinary 5-HIAA could be used as an effective diagnostic test for acute appendicitis. DESIGN AND METHODS: A prospective double-blinded study was carried out from December 2014 to October 2015. Patients admitted to the emergency surgical ward of a teaching hospital with suspected appendicitis were included in the study. The diagnostic accuracy of the test was measured by receiver operating characteristic curve. RESULTS: Ninety-seven patients were divided into 2 groups: acute appendicitis (n=38) and other diagnosis (n=59). The median value of urinary 5-HIAA was 24.19µmol/L (range, 5.39-138.27) for acute appendicitis vs 18.87µmol/L (range, 2.27-120.59) for other diagnosis group (P=.038). The sensitivity and specificity of urinary 5-HIAA at a cutoff value of 19µmol/L were 71% and 50%, respectively. Receiver operating characteristic analysis showed that the area under curve was 0.64 (confidence interval [CI], 0.513-0.737) for urinary 5-HIAA, which was lower than white blood cell count (0.69; CI, 0.574-0.797), neutrophil count (0.68; CI, 0.565-0.792), and C-reactive protein (0.76; CI, 0.657-0.857). There was no significant difference in the median values of 5-HIAA between different grades of severity of appendicitis (P=.704). CONCLUSION: Urinary 5-HIAA is not an ideal test for the diagnosis of acute appendicitis.


Assuntos
Apendicite/urina , Ácido Hidroxi-Indolacético/urina , Dor Abdominal/diagnóstico , Dor Abdominal/urina , Adulto , Apendicite/diagnóstico , Área Sob a Curva , Estudos de Casos e Controles , Constipação Intestinal/diagnóstico , Constipação Intestinal/urina , Método Duplo-Cego , Feminino , Gastroenterite/diagnóstico , Gastroenterite/urina , Humanos , Masculino , Cistos Ovarianos/diagnóstico , Cistos Ovarianos/urina , Estudos Prospectivos , Curva ROC , Cólica Renal/diagnóstico , Cólica Renal/urina , Ruptura Espontânea/diagnóstico , Ruptura Espontânea/urina , Sensibilidade e Especificidade , Infecções Urinárias/diagnóstico , Infecções Urinárias/urina
15.
Surg Endosc ; 30(7): 2834-9, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26490772

RESUMO

BACKGROUND: Conventional laparoscopic instruments used for retraction may cause trauma at the retraction site. Alternative retraction/lifting especially of heavy solid organs such as the liver may be obtained by other means. The present study was designed to explore the use of C3-muco-adhesive polymers (C3-MAPs), which exhibit strong binding to the liver shortly after application to the organ and which retain strong adhesion for sufficient time, to enable sustained retraction during laparoscopic operations. METHODS AND MATERIALS: C3-muco-adhesive polymers were produced specifically for the study. In an ex vivo experimental set-up, discs of C3-MAPs were placed on the surface of porcine livers for adhesion and retraction studies involving objective measurements by tensiometry. RESULTS: Experiments were carried out on 14 porcine livers. The force required to detach the C3-MAPs from the liver exceeded 2.0 N 30 s after application. The adhesion force by C3-MAPs files was sufficient to enable sustained retraction force necessary for exposure of the gall bladder, which was achieved by a mean retraction force of 4.85 N (SD = 0.63). This was sustained for a mean of 130 min (range 17.0-240.0). In the adhesion studies, the forces at 30 s required to detach the polymer discs from the liver exceeded 20 N (upper limit of the load cells of the Instron). The duration of the adhesion enabled sustained optimal gall bladder exposure for periods ranging from 17 to 240 min, with a mean of 130 ± 91 min. CONCLUSIONS: The results of the present study demonstrate that the adhesion and retraction properties of the engineered C3-MAP films are sufficient to enable complete exposure of the gall bladder for a period exceeding 1 h, confirming their potential for atraumatic retraction in laparoscopic and other minimal-access surgical approaches.


Assuntos
Acrilatos/uso terapêutico , Derivados da Hipromelose/uso terapêutico , Laparoscopia/métodos , Fígado , Poloxâmero/uso terapêutico , Adesivos Teciduais/uso terapêutico , Abdome , Animais , Fenômenos Mecânicos , Suínos
16.
Am J Surg ; 210(3): 545-53, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26092443

RESUMO

BACKGROUND: Mental training is rehearsal of mental imagery without physically performing the task. The aim of the study was to perform systematic review and meta-analysis on all the available data to evaluate the role of mental training in the acquisition of surgical technical skills. METHODS: The following search databases were used: EMBASE, MEDLINE, Web of Science, Clinicaltrials.gov.uk, SIGN guidelines, NICE guidelines, and Cochrane review register. Meta-analysis was performed using Revman 5.2 statistical software. RESULTS: There were a total of 9 randomized controlled trials with 474 participants, of which 189 participants received mental training. Five randomized controlled trials concluded positive impact of mental training. Mental training group did not show any significant improvement in overall performance of the task carried in each study (P = .06). CONCLUSION: Mental training can be used as an important supplementary tool in learning surgical skills when run in parallel with physical training and applied to trainees with some experience of the skill.


Assuntos
Competência Clínica , Cirurgia Geral/educação , Imaginação , Prática Psicológica , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto
17.
Surg Endosc ; 29(3): 614-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25030475

RESUMO

BACKGROUND: Attention is important for the skilful execution of surgery. The surgeon's attention during surgery is divided between surgery and outside distractions. The effect of this divided attention has not been well studied previously. We aimed to compare the effect of dividing attention of novices and experts on a laparoscopic task performance. METHODS: Following ethical approval, 25 novices and 9 expert surgeons performed a standardised peg transfer task in a laboratory setup under three randomly assigned conditions: silent as control condition and two standardised auditory distracting tasks requiring response (easy and difficult) as study conditions. Human reliability assessment was used for surgical task analysis. Primary outcome measures were correct auditory responses, task time, number of surgical errors and instrument movements. Secondary outcome measures included error rate, error probability and hand specific differences. Non-parametric statistics were used for data analysis. RESULTS: 21109 movements and 9036 total errors were analysed. Novices had increased mean task completion time (seconds) (171 ± 44SD vs. 149 ± 34, p < 0.05), number of total movements (227 ± 27 vs. 213 ± 26, p < 0.05) and number of errors (127 ± 51 vs. 96 ± 28, p < 0.05) during difficult study conditions compared to control. The correct responses to auditory stimuli were less frequent in experts (68 %) compared to novices (80 %). There was a positive correlation between error rate and error probability in novices (r (2) = 0.533, p < 0.05) but not in experts (r (2) = 0.346, p > 0.05). CONCLUSION: Divided attention conditions in theatre environment require careful consideration during surgical training as the junior surgeons are less able to focus their attention during these conditions.


Assuntos
Atenção , Competência Clínica , Laparoscopia/educação , Cirurgiões/educação , Análise e Desempenho de Tarefas , Adulto , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Cirurgiões/psicologia , Adulto Jovem
18.
Surg Laparosc Endosc Percutan Tech ; 24(4): e137-9, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25077643

RESUMO

Intragastric balloon insertion can achieve reasonable weight loss before antiobesity surgery. Removal needs to be followed by surgery to prevent subsequent weight gain. This study aims to establish the feasibility and safety of retrieval of the intragastric balloon and sleeve gastrectomy in the same sitting. Patients who had a laparoscopic sleeve gastrectomy (n=9) were compared with those who had endoscopic removal of intragastric balloon followed by laparoscopic sleeve gastrectomy in the same sitting (n=5). The 5 patients managed with an intragastric balloon were significantly heavier at all stages of their treatment (P=0.04). The operating time for balloon removal and concomitant sleeve gastrectomy was longer than that of sleeve gastrectomy alone (P=0.035). There were no complications in either group and postoperative hospital stay was similar. In conclusion, concomitant retrieval of an intragastric balloon followed by sleeve gastrectomy is feasible, safe, and cost effective.


Assuntos
Remoção de Dispositivo/métodos , Balão Gástrico , Gastroplastia/instrumentação , Laparoscopia/métodos , Obesidade Mórbida/cirurgia , Cuidados Pós-Operatórios/métodos , Redução de Peso/fisiologia , Adulto , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade Mórbida/fisiopatologia , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
19.
HPB (Oxford) ; 15(7): 511-6, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23750493

RESUMO

BACKGROUND: The aim of this study was to review a series of consecutive percutaneous cholecystostomies (PC) to analyse the clinical outcomes. METHODS: All patients who underwent a PC between 2000 and 2010 were reviewed retrospectively for indications, complications, and short- and long-term outcomes. RESULTS: Fifty-three patients underwent a PC with a median age was 74 years (range 14-93). 92.4% (n = 49) of patients were American Society of Anesthesiologists (ASA) III and IV. 82% (43/53) had ultrasound-guided drainage whereas 18% (10/53) had computed tomography (CT)-guided drainage. 71.6% (n = 38) of PC's employed a transhepatic route and 28.4% (n = 15) transabdominal route. 13% (7/53) of patients developed complications including bile leaks (n = 5), haemorrhage (n = 1) and a duodenal fistula (n = 1). All bile leaks were noted with transabdominal access (5 versus 0, P = 0.001). 18/53 of patients underwent a cholecystectomy of 4/18 was done on the index admission. 6/18 cholecystectomies (33%) underwent a laparoscopic cholecystectomy and the remaining required conversion to an open cholecystectomy (67%). 13/53 (22%) patients were readmitted with recurrent cholecystitis during follow-up of which 7 (54%) had a repeated PC. 12/53 patients died on the index admission. The overall 1-year mortality was 37.7% (20/53). CONCLUSIONS: Only a small fraction of patients undergoing a PC proceed to a cholecystectomy with a high risk of conversion to an open procedure. A quarter of patients presented with recurrent cholecystitis during follow-up. The mortality rate is high during the index admission from sepsis and within the 1 year of follow-up from other causes.


Assuntos
Colecistite Aguda/cirurgia , Colecistostomia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fístula Anastomótica/etiologia , Colecistectomia Laparoscópica , Colecistite Aguda/diagnóstico por imagem , Colecistite Aguda/mortalidade , Colecistostomia/efeitos adversos , Colecistostomia/mortalidade , Drenagem , Duodenopatias/etiologia , Feminino , Humanos , Fístula Intestinal/etiologia , Masculino , Pessoa de Meia-Idade , Nova Zelândia , Readmissão do Paciente , Hemorragia Pós-Operatória/etiologia , Recidiva , Estudos Retrospectivos , Escócia , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ultrassonografia , Adulto Jovem
20.
Patient Saf Surg ; 6(1): 21, 2012 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-22931540

RESUMO

BACKGROUND: A significant proportion of surgical patients are unintentionally harmed during their hospital stay. Root Cause Analysis (RCA) aims to determine the aetiology of adverse incidents that lead to patient harm and produce a series of recommendations, which would minimise the risk of recurrence of similar events, if appropriately applied to clinical practice. A review of the quality of the adverse incident reporting system and the RCA of serious adverse incidents at the Department of Surgery of Ninewells hospital, in Dundee, United Kingdom was performed. METHODS: The Adverse Incident Management (AIM) database of the Department of Surgery of Ninewells Hospital was retrospectively reviewed. Details of all serious (red, sentinel) incidents recorded between May 2004 and December 2009, including the RCA reports and outcomes, where applicable, were reviewed. Additional related information was gathered by interviewing the involved members of staff. RESULTS: The total number of reported surgical incidents was 3142, of which 81 (2.58%) cases had been reported as red or sentinel. 19 of the 81 incidents (23.4%) had been inappropriately reported as red. In 31 reports (38.2%) vital information with regards to the details of the adverse incidents had not been recorded. In 12 cases (14.8%) the description of incidents was of poor quality. RCA was performed for 47 cases (58%) and only 12 cases (15%) received recommendations aiming to improve clinical practice. CONCLUSION: The results of our study demonstrate the need for improvement in the quality of incident reporting. There are enormous benefits to be gained by this time and resource consuming process, however appropriate staff training on the use of this system is a pre-requisite. Furthermore, sufficient support and resources are required for the implementation of RCA recommendations in clinical practice.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA