Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 30(3): 881-5, 2002 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-12367715

RESUMO

A flow injection analysis (FIA) using UV detection, potentiometry and conductometry for levofloxacin (LVF) are described in this study. The best solvent system was found to consist of 0.2 M acetate buffer at pH 3 having 10% MeOH. A flow rate of 1 ml min(-1) was pumped and active material was detected at 288 nm. The detection limit (LOD) and limit of quantification (LOQ) for FIA were calculated to be 3 x 10(-7) M (S/N = 3) and 1 x 10(-7) M (S/N = 10), respectively. In the analysis of tablets, the RSD values were found to be 0.83, 0.98 and 0.99 for FIA, potentiometric and conductometric methods, respectively.


Assuntos
Levofloxacino , Ofloxacino/análise , Condutometria/métodos , Análise de Injeção de Fluxo/métodos , Ofloxacino/química , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/química , Potenciometria/métodos , Espectrofotometria Ultravioleta/métodos
3.
J Pharm Biomed Anal ; 27(5): 841-4, 2002 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-11814727

RESUMO

A flow injection analysis (FIA) of doxazosin mesylate (DOX) using UV detection is described in this study. The best solvent system was found to be consisting of 0.1 mol l(-1) acetate buffer at pH 4 having 10%MeOH. A flow rate of 1 ml min(-1) was pumped and active material was detected at 365 nm. The calibration equation was linear in the range of 1.3 x 10(-5) to 6.4 x 10(-5) mol l(-1). Limit of detection and limit of quantitation were calculated to be 1.6 x 10(-6) and 4 x 10(-6) mol l(-1) with a RSD 1.27 and 1.16% (n=8), respectively. The proposed method was applied to the determination of DOX in the pharmaceutical preparations. The results were compared with those obtained from UV-Spectrophotometry. The results showed that there is a good agreement between FIA method and UV-Spectrophotometry. The validation studies were realised by the related applications and the results were evaluated statistically. According to the results, insignificant difference was observed between the methods.


Assuntos
Antagonistas Adrenérgicos alfa/análise , Doxazossina/análise , Antagonistas Adrenérgicos alfa/química , Doxazossina/química , Análise de Injeção de Fluxo/métodos , Espectrofotometria Ultravioleta/métodos , Comprimidos
6.
J Pharm Biomed Anal ; 25(2): 339-42, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11275442

RESUMO

A flow injection analysis (FIA) of sildenafil citrate (SLD) using UV detection is described in this study. The best solvent system was found to be consisting of 0.2 M phosphate buffer at pH 8 having 10% MeOH. A flow rate of 1 ml. min(-1) was pumped and active material was detected at 292 nm. The calibration equation was linear in the range of 1x10(-6)-5x10(-6) M. Limit of detection (LOD) and limit of quantitation (LOQ) were calculated to be 3x10(-7) and 8.9x10(-7) M with a R.S.D. 1.9 and 0.6% (n=7), respectively. The proposed method was applied to the determination of SLD in VIAGRA tablet, containing 50 mg active material. The results were compared with those obtained from UV-Spectrophotometry. The results showed that there is a good agreement between FIA method and the UV-Spectrophotometry. The validation studies were realised by the related applications and the results were evaluated statistically. According to the results, insignificant difference was observed between the methods.


Assuntos
Piperazinas/análise , Análise de Injeção de Fluxo , Purinas , Reprodutibilidade dos Testes , Citrato de Sildenafila , Soluções , Espectrofotometria Ultravioleta , Sulfonas , Comprimidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA