1.
Cochlear Implants Int ; 23(3): 125-133, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34872461

RESUMO

OBJECTIVES: To investigate the perception of interaural level differences (ILDs) in children with bilateral cochlear implants (BiCIs) and compare them to normal hearing peers. As intracranial shifts in perception of ILDs might have an effect on localization, this was further investigated. METHODS: ILD responses on four different frequency bands (broadband, low-pass, mid-pass and high-pass) were measured in 9 children with BiCIs and 15 children with normal hearing. In the children with BiCIs, 7 of them were implanted sequentially and 2 of them simultaneously. The outcomes were compared with the outcomes from a previous study on advanced localization using the same stimuli as in the current study. The effect of chronological age, inter-implant delay and preoperative residual hearing were also taken into account. RESULTS: No significant differences in ILD responses between children with BiCIs and children with normal hearing were found. For broadband stimuli, children with sequential BiCIs showed a significant shift in their response towards the first implant. A significant correlation was found between inter-implant delay and shift in ILD response for the broadband and high-pass stimuli. The shift in ILD response had no effect on localization. CONCLUSION: Children with BiCIs are able to perceive ILD responses similar to those of normal hearing children. The inter-implant delay has a negative effect on the lateralization of the response towards the first implant side, indicative of deprivation of high-frequency sounds prior to receiving a second implant. This shift, however, is not associated with a shift in localization response.


Assuntos
Implante Coclear , Implantes Cocleares , Localização de Som , Criança , Audição , Testes Auditivos , Humanos , Localização de Som/fisiologia
2.
Hear Res ; 370: 238-247, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30174182

RESUMO

Different amplification options are available for listeners with congenital unilateral conductive hearing loss (UCHL). For example, bone-conduction devices (BCDs) and middle ear implants. The present study investigated whether intervention with an active BCD, the Bonebridge, or a middle ear implant, the Vibrant Soundbridge (VSB), affected sound-localization performance of listeners with congenital UCHL. Listening with a Bonebridge or VSB might provide access to binaural cues. However, when fitted with the Bonebridge, but not with a VSB, binaural processing might be affected through cross stimulation of the contralateral normal hearing ear, and could interfere with processing of binaural cues. In the present study twenty-three listeners with congenital UCHL were included. To assess processing of binaural cues, we investigated localization abilities of broadband (BB, 0.5-20 kHz) filtered noise presented at varying sound levels. Sound localization abilities were analyzed separately for stimuli presented at the side of the normal-hearing ear, and for stimuli presented at the side of the hearing-impaired ear. Twenty-six normal hearing children and young adults were tested as control listeners. Sound localization abilities were measured under open-loop conditions by recording head-movement responses. We demonstrate improved sound localization abilities of children with congenital UCHL, when listening with a Bonebridge or VSB, predominantly for stimuli presented at the impaired (aided) side. Our results suggest that the improvement is not related to accurate processing of binaural cues. When listening with the Bonebridge, despite cross stimulation of the contralateral cochlea, localization performance was not deteriorated compared to listening with a VSB.


Assuntos
Condução Óssea , Prótese Ancorada no Osso , Anormalidades Congênitas/reabilitação , Crianças com Deficiência/reabilitação , Orelha/anormalidades , Auxiliares de Audição , Perda Auditiva Condutiva/reabilitação , Perda Auditiva Unilateral/reabilitação , Prótese Ossicular , Substituição Ossicular/instrumentação , Pessoas com Deficiência Auditiva/reabilitação , Localização de Som , Estimulação Acústica , Adolescente , Condução Óssea/genética , Estudos de Casos e Controles , Criança , Pré-Escolar , Anormalidades Congênitas/fisiopatologia , Anormalidades Congênitas/psicologia , Sinais (Psicologia) , Crianças com Deficiência/psicologia , Orelha/fisiopatologia , Estimulação Elétrica , Feminino , Perda Auditiva Condutiva/congênito , Perda Auditiva Condutiva/fisiopatologia , Perda Auditiva Condutiva/psicologia , Perda Auditiva Unilateral/congênito , Perda Auditiva Unilateral/fisiopatologia , Perda Auditiva Unilateral/psicologia , Humanos , Masculino , Pessoas com Deficiência Auditiva/psicologia , Desenho de Prótese , Adulto Jovem