Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Bioelectrochemistry ; 158: 108704, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38593574

RESUMO

Need for affordable, rapid and user-friendly point of care (POC) devices are increasing exponentially for strengthening the health care system in primary care as well as for self- monitoring in routine analysis. In addition to routine analysis of glucose, Covid-19 type fast spreading, infectious diseases have created further push for exploring rapid, cost-effective and self-monitoring diagnostic devices. Successful implementation of self-monitoring devices for Covid -19 has been realized. However, not much success has been realized for malaria and dengue which are two fatal diseases that affect the population in underdeveloped and developing countries. To monitor the presence of parasites for these diseases, rapid, onsite monitoring devices are still being explored. In this review, we present a review of the research carried out on electrochemical POC devices for monitoring infectious diseases such as Covid-19, malaria and dengue.


Assuntos
COVID-19 , Dengue , Malária , Sistemas Automatizados de Assistência Junto ao Leito , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , COVID-19/virologia , Malária/diagnóstico , Dengue/diagnóstico , SARS-CoV-2/isolamento & purificação , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação
2.
Anal Biochem ; 689: 115493, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38403259

RESUMO

Aflatoxin B1 (AF-B1) are toxins secreted by secondary metabolites of molds that have adverse effects on humans and animals resulting in huge economic losses. Here we report on field useable, cost effective and direct electrochemical sensor based on conducting polymer composite electrode, Poly (3,4-ethylenedioxythiophene): polystyrene sulphonic acid (PEDOT-PSS) for label-free detection of AF-B1. Structural and morphological characterization of composite electrodes were carried out using XRD and SEM. We compared two different electroanalytical techniques namely, transient capacitance and differential pulse voltammetry, to select the most prominent technique for analyzing the mycotoxin easily. For direct detection of AF-B1, transient capacitance measurement at 77 and 1000 Hz was employed wherein sensor showed linearity in 18.18-300.0 ng mL-1 range at 77 Hz for AF-B1. Best limit of detection (LOD) for AF-B1 was 55.41 ng mL-1 (369 pM) at 77 Hz with very good repeatability. DPV showed linearity in the range 18.18-342.85 ng mL-1 with LOD 435 pM. For demonstration of application of this sensor directly using minimum sample preparation, AF-B1 sensing has been confirmed successfully using white button mushrooms and okra stored at ambient conditions. Sensor response with real samples suggest usefulness of sensor to monitor stored farm products easily.


Assuntos
Aflatoxina B1 , Técnicas Biossensoriais , Animais , Humanos , Aflatoxina B1/análise , Técnicas Biossensoriais/métodos , Imunoensaio , Eletrodos , Técnicas Eletroquímicas/métodos , Limite de Detecção