Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Clin Microbiol ; 56(12)2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30282788

RESUMO

An element essential for PCR detection of microbial agents in many sample types is the extraction step, designed to purify nucleic acids. Despite the importance of this step, yields have not been extensively compared across methods to determine whether the method used contributes to quantitative differences and the lack of commutability seen with existing clinical methods. This may in part explain why plasma and blood viral load assays have proven difficult to standardize. Also, studies have identified small DNA fragments of <200 bp in plasma (cell-free DNA [cfDNA]), which may include significant quantities of viral DNA. Our study evaluated extraction yields for 11 commercially available extraction methods, including 4 new methods designed to isolate cfDNA. Solutions of DNA fragments with sizes ranging from 50 to 1,500 bp were extracted, and then the eluates were tested by droplet digital PCR to determine the DNA fragment yield for each method. The results demonstrated a wide range of extraction yields across the variety of methods/instruments used, with the 50- and 100-bp fragment sizes showing especially inconsistent quantitative results and poor yields of less than 20%. Slightly higher, more consistent yields were seen with 2 of the 4 circulating cell-free extraction kits. These results demonstrate a significant need for further evaluation of nucleic acid yields across the variety of extraction platforms and highlight the poor extraction yields of small DNA fragments by existing methods. Further work is necessary to determine the impact of this inconsistency across instruments and the relevance of the low yields for smaller DNA fragments in clinical virology testing.


Assuntos
Ácidos Nucleicos Livres/isolamento & purificação , Testes Diagnósticos de Rotina/normas , Técnicas de Diagnóstico Molecular/normas , Kit de Reagentes para Diagnóstico/normas , Ácidos Nucleicos Livres/genética , DNA Viral/genética , DNA Viral/isolamento & purificação , Testes Diagnósticos de Rotina/instrumentação , Humanos , Técnicas de Diagnóstico Molecular/instrumentação , Reação em Cadeia da Polimerase/métodos , Reação em Cadeia da Polimerase/normas , Padrões de Referência , Carga Viral/normas
2.
Biotechniques ; 53(3): 182-188, 2012 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-23083368

RESUMO

Fluorescent dye terminator Sanger sequencing (FTSS), with detection by automated capillary electrophoresis (CE), has long been regarded as the gold standard for variant detection. However, software analysis and base-calling algorithms used to detect mutations were largely optimized for resequencing applications in which different alleles were expected as heterozygous mixtures of 50%. Increasingly, the requirements for variant detection are an analytic sensitivity for minor alleles of <20%, in particular, when assessing the mutational status of heterogeneous tumor samples. Here, we describe a simple modification to the FTSS workflow that improves the limit of detection of cell-line gDNA mixtures from 50%-20% to 5% for G>A transitions and from 50%-5% to 5% for G>C and G>T transversions. In addition, we use two different sample types to compare the limit of detection of sequence variants in codons 12 and 13 of the KRAS gene between Sanger sequencing and other methodologies including shifted termination assay (STA) detection, single-base extension (SBE), pyrosequencing (PS), high- resolution melt (HRM), and real-time PCR (qPCR).

3.
Biotechniques ; 53(3): 182-8, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22963480

RESUMO

Fluorescent dye terminator Sanger sequencing (FTSS), with detection by automated capillary electrophoresis (CE), has long been regarded as the gold standard for variant detection. However, software analysis and base-calling algorithms used to detect mutations were largely optimized for resequencing applications in which different alleles were expected as heterozygous mixtures of 50%. Increasingly, the requirements for variant detection are an analytic sensitivity for minor alleles of <20%, in particular, when assessing the mutational status of heterogeneous tumor samples. Here, we describe a simple modification to the FTSS workflow that improves the limit of detection of cell-line gDNA mixtures from 50%-20% to 5% for G>A transitions and from 50%-5% to 5% for G>C and G>T transversions. In addition, we use two different sample types to compare the limit of detection of sequence variants in codons 12 and 13 of the KRAS gene between Sanger sequencing and other methodologies including shifted termination assay (STA) detection, single-base extension (SBE), pyrosequencing (PS), high- resolution melt (HRM), and real-time PCR (qPCR).


Assuntos
Análise Mutacional de DNA/métodos , Proteínas Proto-Oncogênicas/genética , Proteínas ras/genética , Linhagem Celular , DNA/análise , DNA/química , Análise Mutacional de DNA/normas , Eletroforese Capilar , Corantes Fluorescentes/química , Genoma Humano , Técnicas de Genotipagem/métodos , Técnicas de Genotipagem/normas , Humanos , Limite de Detecção , Proteínas Proto-Oncogênicas p21(ras)
4.
J Mol Diagn ; 14(3): 187-91, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22414609

RESUMO

In recent years, the mutational status of the KRAS oncogene has become incorporated into standard medical care as a predictive marker for therapeutic decisions related to patients with metastasized colorectal cancer. This is necessary, because these patients benefit from epidermal growth factor receptor (EGFR)-targeted therapy with increased progression-free survival only if the tumor does not carry a mutation in KRAS. Many different analytical platforms, both those commercially available and those developed in house, have been used within pathology laboratories to assess KRAS mutational status. For a testing laboratory to become accredited to perform such tests, it is essential that they perform reliability testing, but it has not previously been possible to perform this kind of testing on the complete workflow on a large scale without compromising reproducibility or the mimicry of the control sample. We assessed a novel synthetic control for formalin-fixed, paraffin-embedded (FFPE) tumor samples in a blind study conducted within nine laboratories across Europe. We show that FFPE material can, at least in part, mimic clinical samples and we demonstrate this control to be a valuable tool in the assessment of platforms used in testing for KRAS mutational status.


Assuntos
Neoplasias Colorretais , Análise Mutacional de DNA/normas , Genes ras , Técnicas de Diagnóstico Molecular/normas , Proteínas Proto-Oncogênicas/genética , Proteínas ras/genética , Linhagem Celular Tumoral , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/genética , Receptores ErbB/antagonistas & inibidores , Fixadores , Formaldeído , Humanos , Mutação , Inclusão em Parafina , Proteínas Proto-Oncogênicas p21(ras) , Controle de Qualidade , Reprodutibilidade dos Testes
5.
J Mol Diagn ; 13(6): 583-604, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21871973

RESUMO

The superior sensitivity and specificity associated with the use of molecular assays has greatly improved the field of infectious disease diagnostics by providing clinicians with results that are both accurate and rapidly obtained. Herein, we review molecularly based infectious disease diagnostic tests that are Food and Drug Administration approved or cleared and commercially available in the United States as of December 31, 2010. We describe specific assays and their performance, as stated in the Food and Drug Administration's Summary of Safety and Effectiveness Data or the Office of In Vitro Diagnostic Device Evaluation and Safety's decision summaries, product inserts, or peer-reviewed literature. We summarize indications for testing, limitations, and challenges related to implementation in a clinical laboratory setting for a wide variety of common pathogens. The information presented in this review will be particularly useful for laboratories that plan to implement or expand their molecular offerings in the near term.


Assuntos
Técnicas de Laboratório Clínico , Doenças Transmissíveis/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Doenças Transmissíveis/genética , Aprovação de Teste para Diagnóstico , Humanos , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade , Estados Unidos , United States Food and Drug Administration
6.
Clin Chem ; 55(9): 1701-10, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19574467

RESUMO

BACKGROUND: Viral load testing for cytomegalovirus (CMV) is an important diagnostic tool for the management of transplant recipients and immunocompromised individuals; however, inconsistency among laboratories in quantitative measurements of viral load limits interinstitutional comparisons. These inconsistencies stem from the lack of assays cleared by the US Food and Drug Administration, the absence of international standards, the wide variety of CMV-extraction and -detection methods, and differences in materials used for calibration. A critical component of standardization is the use of calibrators that are traceable and commutable. METHODS: Bland-Altman plots and prediction ellipses were used to test the commutability of 2 CMV calibrators for 2 different quantification methods. RESULTS: Tests with 2 methods showed 1 calibrator to be commutable and the other to be noncommutable. The results for the commutable calibrator were within the 95% prediction interval of the clinical samples in the Bland-Altman plot and within the 95% prediction ellipse for a simulated commutable calibrator, whereas the results for the noncommutable calibrator were not within these prediction intervals. When used to calibrate patient results, only the commutable calibrator, the OptiQuant CMV(tc) Calibration Panel, significantly improved the comparability of viral loads for the 2 different measurement methods. CONCLUSIONS: This study demonstrates that an important goal in the effort to improve healthcare for patients with CMV-related disease is the establishment of traceable and commutable reference materials, including both calibrators and controls. .


Assuntos
Infecções por Citomegalovirus/sangue , Infecções por Citomegalovirus/virologia , Citomegalovirus/isolamento & purificação , Carga Viral/métodos , Carga Viral/normas , Calibragem , DNA Viral/análise , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA