Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Medicine (Baltimore) ; 100(51): e28315, 2021 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-34941127

RESUMO

ABSTRACT: Circulating HIV subtypes in the Philippines have increasingly diversified, potentially affecting treatment. We monitored outcomes of a treatment-naïve cohort and their virus subtype prevalence.Retrospective/prospective study cohort.HIV-I-REACT clinic patients co-enrolled in the Virology Quality Assurance Program (RUSH-VQA) from 7/2017-6/2019 were included. Relevant demographic and laboratory information were collected. The ViroSeq HIV-1 Genotyping System v.3 and HIV-1 Integrase Genotyping Kit identified protease-reverse transcriptase and integrase drug resistance mutations (DRM). Sequence subtyping followed using the Stanford University Drug Resistance Database and the REGA HIV-1 Subtyping Tool v.3. The jpHMM HIV-1 Tool and REGA HIV-1 Subtyping Tool provided additional subtype analysis of this cohort's 5'LTR-VIF regions after Sanger sequencing. One-year outcomes included virologic suppression, mortality, and follow-up.86/88 patients were males. Median age was 30 (range 19-65) years; 61/88 were MSM. 15/85 carried baseline DRM. ViroSeq-generated sequences included subtypes CRF01_AE (66/85), B (14/85), and newer recombinants (4/85). Extensive sequencing (n = 71) of the 5'-LTR-GAG-Pol genes showed CRF01_AE (n = 50), subtype B (n = 7), and other recombinants (n = 13). Bootstrap analysis identified 7 pairs of highly related strains. Discordant DRM appeared in 2/7 pairs, where 1/2 strains displayed DRM. After 1 year, 87 individuals were alive, with 19 lost to care. Viral load (VL) was repeated for only 31/77 (40.2%). Follow-up CD4 testing for 39/77 (50.6%) showed an increase to a median of 327 cells/mm3.Our cohort currently carries subtype CRF01_AE (∼68%-70%), followed by subtype B and CRF01_AE/B recombinants. Outcomes were favorable, regardless of subtype after 1 year on cART.


Assuntos
Infecções por HIV/epidemiologia , HIV-1/genética , Adulto , Idoso , Feminino , Genótipo , Infecções por HIV/tratamento farmacológico , Soropositividade para HIV , HIV-1/isolamento & purificação , Humanos , Masculino , Pessoa de Meia-Idade , Filipinas/epidemiologia , Filogenia , Reação em Cadeia da Polimerase , Estudos Prospectivos , Estudos Retrospectivos , Sequenciamento Completo do Genoma , Adulto Jovem
2.
Viruses ; 12(12)2020 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-33348705

RESUMO

The National Institute of Allergy and Infectious Diseases (NIAID) Virology Quality Assurance (VQA) established a robust proficiency testing program for Sanger sequencing (SS)-based HIV-1 drug resistance (HIVDR) testing in 2001. While many of the lessons learned during the development of such programs may also apply to next generation sequencing (NGS)-based HIVDR assays, challenges remain for the ongoing evaluation of NGS-based testing. These challenges include a proper assessment of assay accuracy and the reproducibility of low abundance variant detection, intra- and inter-assay performance comparisons among laboratories using lab-defined tests, and different data analysis pipelines designed for NGS. In collaboration with the World Health Organization (WHO) Global HIVDR Laboratory Network and the Public Health Agency of Canada, the Rush VQA program distributed archived proficiency testing panels to ten laboratories to evaluate internally developed NGS assays. Consensus FASTA files were submitted using 5%, 10%, and 20% variant detection thresholds, and scored based on the same criteria used for SS. This small study showed that the SS External Quality Assurance (EQA) approach can be used as a transitional strategy for using NGS to generate SS-like data and for ongoing performance while using NGS data from the same quality control materials to further evaluate NGS assay performance.


Assuntos
Farmacorresistência Viral , Genoma Viral , Genótipo , Infecções por HIV/virologia , HIV-1/efeitos dos fármacos , HIV-1/fisiologia , Sequência de Bases , Sequência Consenso , Infecções por HIV/tratamento farmacológico , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Análise de Sequência de DNA
3.
J Virol Methods ; 261: 91-97, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30125614

RESUMO

BACKGROUND: Commercially-available kits for HIV-1 detection include instructions for detecting HIV-1 in plasma and DBS, but don't support other specimen types. OBJECTIVES: Show quantitative stability of HIV-1 total nucleic acid (TNA) in blood and improved HIV-1 detection in alternative specimen types. STUDY DESIGN: Whole blood and DBS specimens, tested as part of an external quality assurance program for qualitative HIV-1 detection, were used to evaluated error rates (false negative [FN], false positive [FP] and indeterminant [IND] results) across assays (internally developed [IH], Roche Amplicor [RA], and Roche TaqMan Qual [TQ]) and specimen types (frozen whole blood [BLD], DBS and cell pellets [PEL]). A modified Roche TaqMan HIV-1 assay was used to quantify HIV-1 TNA. RESULTS: Significantly higher error rates were noted in DBS across all of the assays (4% vs. 0% for DBS and PEL, IH, p = 0.005; 4% vs. 0.1% for DBS and PEL, RA, p < 0.001; 10% vs. 1% for DBS and PEL or BLD, TQ, p < 0.001). HIV TNA concentration is stable in BLD (day 1 vs. day 10, p = 0.39) and higher than DBS (p < 0.001). CONCLUSIONS: Transporting refrigerated whole blood for centralized processing into alternative specimen types will improve the sensitivitiy of HIV-1 detection in samples with low virus loads.


Assuntos
Infecções por HIV/diagnóstico , HIV-1/isolamento & purificação , RNA Viral/análise , Manejo de Espécimes/métodos , Erros de Diagnóstico , HIV-1/genética , RNA Viral/genética , Sensibilidade e Especificidade
4.
J Clin Microbiol ; 56(6)2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29618501

RESUMO

The National Institute of Allergy and Infectious Diseases (NIAID) AIDS Clinical Trials Group (ACTG) stores specimens from its clinical trials in a biorepository and permits the use of these specimens for nonprotocol exploratory studies, once the studies for the original protocol are concluded. We sought to assess the comparability of the data generated from real-time HIV-1 RNA testing during two clinical trials with the data generated from the retesting of different aliquots of the same samples after years of storage at -80°C. Overall, there was 92% agreement in the data generated for 1,570 paired samples (kappa statistic = 0.757; 95% confidence interval [CI], 0.716 to 0.797), where samples were tested in one laboratory using the microwell plate (MWP) version of the Roche HIV-1 Monitor test within 1 to 37 days of collection and retested in another laboratory using the Cobas version of the assay after a median of 6.7 years of storage (range, 5.7 to 8.6 years). Historical external quality control data submitted to the NIAID Virology Quality Assurance program (VQA) by client laboratories using the same two versions of the Monitor assay were used to differentiate between systematic differences in the assays to evaluate the stability of HIV-1 RNA in the stored samples. No significant loss of RNA was noted in samples containing either a low concentration (<50 copies/ml) or a high concentration (≥50 copies/ml) of HIV-1 RNA (P = 0.10 and P = 0.90, respectively) regardless of the time in storage. These data confirm the quality of the plasma samples in the ACTG biorepository following long-term storage.


Assuntos
HIV-1/genética , Laboratórios , Controle de Qualidade , Estabilidade de RNA , RNA Viral/genética , Manejo de Espécimes/normas , Bancos de Espécimes Biológicos , Análise de Dados , Infecções por HIV/sangue , Infecções por HIV/virologia , Humanos , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade , Carga Viral
5.
J Clin Microbiol ; 53(8): 2659-66, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26063861

RESUMO

Discrepancies between HIV-1 RNA results assayed by different FDA-approved platforms have been reported. Plasma samples collected from 332 randomly selected clinical trial participants during the second year of antiretroviral treatment were assayed with three FDA-approved platforms: UltraSensitive Roche Amplicor Monitor, v1.5 (Monitor), the Abbott RealTime HIV-1 test on the m2000 system (Abbott), and the Roche TaqMan HIV-1 test, v2.0 (TaqMan). Samples from 61 additional participants with confirmed HIV-1 RNA levels of >50 copies/ml during trial follow-up were also included. Endpoints were HIV-1 RNA quantification of ≤50 copies/ml versus >50 copies/ml at an individual-sample level (primary) and determination of confirmed virologic failure (VF) from longitudinal samples. A total of 389 participants had results obtained from all assays on at least one sample (median = 6). Proportions of results of >50 copies/ml were 19% (Monitor), 22% (TaqMan), and 25% (Abbott). Despite indication of strong agreement (Cohen's kappa, 0.76 to 0.82), Abbott was more likely to detect HIV-1 RNA levels of >50 copies/ml than Monitor (matched-pair odds ratio [mOR] = 4.2; modified Obuchowski P < 0.001) and TaqMan (mOR = 2.1; P < 0.001); TaqMan was more likely than Monitor (mOR = 2.6; P < 0.001). Despite strong agreement in classifying VF across assay comparisons (kappa, 0.75 to 0.92), at a 50-copies/ml threshold, differences in the probability of VF classification (in the same direction as primary) were apparent (all McNemar's P < 0.007). At a 200-copies/ml VF threshold, no differences between assays were apparent (all P > 0.13). Despite strong agreement among assays, significant differences were observed with respect to detecting HIV-1 RNA levels of >50 copies/ml and identifying VF at the 50-copies/ml threshold. This has important implications for the definition of VF in clinical trials and clinical practice.


Assuntos
Infecções por HIV/virologia , HIV-1/isolamento & purificação , Plasma/virologia , RNA Viral/sangue , Carga Viral/métodos , Adolescente , Adulto , Idoso , Antirretrovirais/uso terapêutico , Feminino , Infecções por HIV/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Falha de Tratamento , Adulto Jovem
6.
Am J Clin Pathol ; 140(6): 881-9, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24225757

RESUMO

OBJECTIVES: To evaluate an external quality assurance (EQA) program for the laboratory diagnosis of human papillomavirus (HPV) disease that was established to improve international research capability within the Division of AIDS at the National Institute of Allergy and Infectious Disease-supported Adult AIDS Clinical Trials Group network. METHODS: A three-component EQA scheme was devised comprising assessments of diagnostic accuracy of cytotechnologists and pathologists using available EQA panels, review of quality and accuracy of clinical slides from local sites by an outside expert, and HPV DNA detection using a commercially available HPV test kit. RESULTS: Seven laboratories and 17 pathologists in Africa, India, and South America participated. EQA scores were suboptimal for EQA proficiency testing panels in three of seven laboratories. There was good agreement between the local laboratory and the central reader 70% of the time (90% confidence interval, 42%-98%). Performance on the College of American Pathologists' HPV DNA testing panel was successful in all laboratories tested. CONCLUSIONS: The prequalifying EQA round identified correctable issues that will improve the laboratory diagnosis of HPV-related cervical disease at the participating international study sites and will provide a mechanism for ongoing education and continuous quality improvement.


Assuntos
Testes de DNA para Papilomavírus Humano/normas , Laboratórios/normas , Infecções por Papillomavirus/diagnóstico , Garantia da Qualidade dos Cuidados de Saúde/normas , Neoplasias do Colo do Útero/prevenção & controle , Síndrome da Imunodeficiência Adquirida , Ensaios Clínicos Fase II como Assunto , Feminino , Testes de DNA para Papilomavírus Humano/métodos , Humanos , Programas de Rastreamento/métodos , National Institutes of Health (U.S.) , Patologia/normas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Estados Unidos
7.
J Clin Microbiol ; 50(8): 2737-47, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22692747

RESUMO

HIV-1 RNA quantitation continues to be extremely important for monitoring patients infected with HIV-1, and a number of assays have been utilized for this purpose. Differences in assay performance with respect to log(10) recovery and HIV-1 subtype specificity have been well documented for commercially available assays, although comparisons are usually limited to one or two assay platforms. Two new FDA-approved assays, the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test (RT) and the Abbott RealTime HIV-1 assay (AR), that utilize real-time PCR have replaced previous HIV-1 RNA platforms. Inadequate detection of some strains of HIV-1 resulted in the addition of a new primer/probe set and the introduction of a second version of the RT assay. In this study, comparisons of assay performance between the different FDA-approved HIV-1 RNA assay platforms (both new and existing) were performed by using validation data that included both well-characterized virus stock and locally collected clinical samples. Laboratories across diverse geographical regions performed the validation testing and submitted data to the Virology Quality Assurance program (VQA) for analysis. Correlation values for clinical sample testing varied across the assay platforms (r = 0.832 to 0.986), and average log(10) recoveries for HIV-1 RNA controls (compared to the nominal value) ranged from -0.215 to 0.181. These data demonstrate the need for use of one assay platform for longitudinal patient monitoring, but the data also reinforce the notion that no one assay is superior and that testing across platforms may be required for discordance reconciliation.


Assuntos
Infecções por HIV/diagnóstico , Infecções por HIV/virologia , HIV-1/isolamento & purificação , RNA Viral/sangue , Reação em Cadeia da Polimerase em Tempo Real/métodos , Carga Viral/métodos , Humanos , Garantia da Qualidade dos Cuidados de Saúde , Reação em Cadeia da Polimerase em Tempo Real/normas , Carga Viral/normas
8.
Clin Infect Dis ; 54 Suppl 4: S266-72, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22544186

RESUMO

The World Health Organization (WHO) has developed a global laboratory network to support human immunodeficiency virus drug resistance genotyping for public health surveillance in resource-limited countries. Blinded proficiency panels are an essential part of a genotyping quality-assurance program and are used to monitor the reliability of genotyping data in the WHO laboratory network. Laboratories in Europe, North America, Asia, Africa, and the Caribbean have tested panels annually since 2007; 103 of 131 submissions (79%) had >99% nucleotide sequence identity and resistance mutation concordance, compared with consensus. Most errors were associated with mixtures in the test specimen, leading to subjectivity in base-calling or amplification bias. Overall, genotyping assays used by the WHO laboratory network are reliable.


Assuntos
Antirretrovirais/farmacologia , Farmacorresistência Viral/genética , Técnicas de Genotipagem/normas , Infecções por HIV/tratamento farmacológico , Infecções por HIV/virologia , HIV/genética , Laboratórios/normas , Antirretrovirais/uso terapêutico , HIV/efeitos dos fármacos , Humanos , Ensaio de Proficiência Laboratorial , Vigilância da População , Reprodutibilidade dos Testes , Virologia/normas , Organização Mundial da Saúde
9.
Clin Infect Dis ; 54 Suppl 4: S273-9, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22544187

RESUMO

In resource-limited settings, there is increased demand for human immunodeficiency virus type 1 drug resistance testing. Because preservation of plasma specimens is often not feasible in resource-limited settings, use of dried blood spots (DBSs) is being adopted. We used 2 panels of DBSs for genotyping assay validation and proficiency testing in selected laboratories in the World Health Organization laboratory network in 14 countries. An amplification sensitivity of 1000 copies/mL was achieved by 2 laboratories. Reproducibility and accuracy of nucleotide sequence determination and resistance-associated mutation identification from DBSs was similar to that previously determined for plasma. International shipping at ambient temperature had no significant effect on amplification success. These studies indicate that DBS-based genotyping is equally reproducible and reliable, although slightly less sensitive, compared with plasma.


Assuntos
Teste em Amostras de Sangue Seco/métodos , Técnicas de Genotipagem/métodos , Infecções por HIV/sangue , Infecções por HIV/virologia , HIV-1/genética , Teste em Amostras de Sangue Seco/normas , Farmacorresistência Viral/genética , Genótipo , Técnicas de Genotipagem/normas , Humanos , Laboratórios , Reação em Cadeia da Polimerase , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Análise de Sequência de DNA , Temperatura , Carga Viral/métodos , Carga Viral/normas , Organização Mundial da Saúde
10.
J Clin Microbiol ; 49(8): 2854-8, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21697326

RESUMO

The performance characteristics of four different assays for hepatitis B virus (HBV) quantification were assessed: the Abbott RealTime HBV IUO, the Roche Cobas AmpliPrep/Cobas TaqMan HBV test, the Roche Cobas TaqMan HBV test with HighPure system, and the Qiagen artus HBV TM ASR. Limit of detection (LOD), linear range, reproducibility, and agreement were determined using a serially diluted plasma sample from a single chronically infected subject. Each assay was tested by at least three laboratories. The LOD of the RealTime and two TaqMan assays was approximately 1.0 log(10) IU/ml; for artus HBV (which used the lowest volume of extracted DNA), it was approximately 1.5 log(10) IU/ml. The linear range spanned 1.0 to at least 7.0 log(10) IU/ml for all assays. Median values were consistently lowest for artus HBV and highest for Cobas AmpliPrep/Cobas TaqMan HBV. Assays incorporating automated nucleic acid extraction were the most reproducible; however, the overall variability was minor since the standard deviations for the means of all tested concentrations were ≤0.32 log(10) IU/ml for all assays. False-positive results were observed with all assays; the highest rates occurred with tests using manual nucleic acid extraction. The performance characteristics of these assays suggest that they are useful for management and therapeutic monitoring of chronic HBV infection.


Assuntos
DNA Viral/isolamento & purificação , Vírus da Hepatite B/isolamento & purificação , Hepatite B/virologia , Reação em Cadeia da Polimerase em Tempo Real/métodos , Carga Viral/métodos , DNA Viral/genética , Vírus da Hepatite B/genética , Humanos , Plasma/virologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Appl Opt ; 50(18): 3015-20, 2011 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-21691369

RESUMO

A zone plate composed of Mo zones having 4 mm outermost zone diameter, 100 nm outermost zone width, and supported on a silicon nitride membrane was characterized using monochromatic synchrotron radiation in the 2 to 20 nm wavelength range. The zero and first order efficiencies were measured and compared to ab initio calculations that account for the optical properties of the materials, the width and shape of the zones, and multiple-layer thin-film effects. It is shown that the thicknesses of the Mo zones and the membrane and the ratio of the zone width to zone period can be independently determined from the measured diffraction efficiencies in the zero and first orders and that the computational code can be used to reliably design zone plates that are optimized for applications such as solar irradiance monitors in the extreme ultraviolet region.

12.
ISRN Obstet Gynecol ; 2011: 524365, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21647213

RESUMO

HIV-serodiscordant couples wishing to conceive often seek assisted reproduction, during which spermatozoa from infected men are washed to minimize the risk of HIV transmission to partner and fetus. We sought to improve this method by adding a microbicide, PPCM, as an HIV prophylactic. HIV-1 (BaL) inhibition by PPCM appears irreversible and independent of added Ca(2+). Without added Ca(2+), PPCM (≤10 mg/mL, ≤90 min), a stimulus of Ca(2+)-dependent acrosomal loss, has no effect on sperm motility, forward progression, or acrosomal status. PPCM-treated (10 mg/mL) sperm retain their ability to acrosome react when Ca(2+) is added. Sperm DNA integrity/function is unaffected by PPCM (≤10 mg/mL). Adding PPCM (5 mg/mL, 30 min) to washing media reduces infectivity (viral antigen p24 and RNA) of ex-vivo HIV-infected semen by 3-4 Logs compared with washing alone. Sperm washing with appropriate extracellular Ca(2+) levels and PPCM is significantly more effective than washing alone at reducing HIV infectivity.

13.
Appl Opt ; 48(31): 5970-7, 2009 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-19881664

RESUMO

The diffraction efficiency, focal length, and other radiometric and metrology properties of a phase zone plate were measured by using monochromatic synchrotron radiation in the 7-18.5 nm wavelength range. The zone plate was composed of molybdenum zones having a 4 mm outer diameter and 70 nm nominal thickness and supported on a 100 nm thick silicon nitride membrane. The diffraction efficiency was enhanced by the phase shift of the radiation passing through the zones. The measured first-order efficiency was in good agreement with the calculated efficiency. The properties of the zone plate, particularly the small variation of the efficiency with off-axis angle, make it suitable for use in a radiometer to accurately measure the absolutely calibrated extreme ultraviolet emission from the Sun.

14.
AIDS Res Hum Retroviruses ; 25(10): 1039-43, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19795987

RESUMO

Sequence characterization of the near full-length genomes of HIV-1 isolates BCF-Dioum and BCF-Kita, originating from the Democratic Republic of Congo (DRC), was continued. These NED panel isolates, contributed by F. Brun-Vezinet (ENVA-France), were first identified as subtypes G and H, respectively. Our earlier analyses of portions of their pol genes showed that both were likely to be intersubtype recombinants of different composition. This study analyzed the remainder of each genome, confirming them to be complex recombinants. The BCF-Dioum genome resembles CRF06_cpx strains found in West Africa, composed of subtypes A/G/J/K. The BCF-Kita genome is a unique complex recombinant A-F-G-H-K-U strain. These data support previous observations of the complexity of strains originating from the DRC. BCF-Dioum may be a suitable strain for standards and reagents since it matches a defined circulating recombinant form. Studies and reagents made from BCF-Kita should take into account its complex genome.


Assuntos
Genoma Viral , Infecções por HIV/virologia , HIV-1/classificação , HIV-1/genética , Análise por Conglomerados , República Democrática do Congo , Evolução Molecular , Genótipo , HIV-1/isolamento & purificação , Humanos , Dados de Sequência Molecular , Filogenia , Recombinação Genética , Análise de Sequência de DNA , Homologia de Sequência
15.
J Clin Microbiol ; 47(11): 3530-9, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19726602

RESUMO

Microbicide candidates with promising in vitro activity are often advanced for evaluations using human primary tissue explants relevant to the in vivo mucosal transmission of human immunodeficiency virus type 1 (HIV-1), such as tonsil, cervical, or rectal tissue. To compare virus growth or the anti-HIV-1 efficacies of candidate microbicides in tissue explants, a novel soft-endpoint method was evaluated to provide a single, objective measurement of virus growth. The applicability of the soft endpoint is shown across several different ex vivo tissue types, with the method performed in different laboratories, and for a candidate microbicide (PRO 2000). The soft-endpoint method was compared to several other endpoint methods, including (i) the growth of virus on specific days after infection, (ii) the area under the virus growth curve, and (iii) the slope of the virus growth curve. Virus growth at the assay soft endpoint was compared between laboratories, methods, and experimental conditions, using nonparametric statistical analyses. Intra-assay variability determinations using the coefficient of variation demonstrated higher variability for virus growth in rectal explants. Significant virus inhibition by PRO 2000 and significant differences in the growth of certain primary HIV-1 isolates were observed by the majority of laboratories. These studies indicate that different laboratories can provide consistent measurements of anti-HIV-1 microbicide efficacy when (i) the soft endpoint or another standardized endpoint is used, (ii) drugs and/or virus reagents are centrally sourced, and (iii) the same explant tissue type and method are used. Application of the soft-endpoint method reduces the inherent variability in comparisons of preclinical assays used for microbicide development.


Assuntos
Anti-Infecciosos/farmacologia , HIV-1/efeitos dos fármacos , Testes de Sensibilidade Microbiana/métodos , Testes de Sensibilidade Microbiana/normas , Colo do Útero/virologia , Feminino , Humanos , Técnicas In Vitro , Masculino , Mucosa/virologia , Tonsila Palatina/virologia , Reto/virologia , Reprodutibilidade dos Testes , Replicação Viral/efeitos dos fármacos
16.
J Antimicrob Chemother ; 64(1): 33-6, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19403653

RESUMO

OBJECTIVES: Dried blood spots (DBS) and dried plasma spots (DPS) are considered convenient alternatives to serum and plasma for HIV drug resistance testing in resource-limited settings. We sought to investigate how extreme conditions could affect the short-term ability to amplify and genotype HIV from DBS. METHODS: A panel of six matched DPS/DBS was generated using blood collected from HIV-infected donors. Replicate cards were prepared in 903 filter paper using 50 microL of blood and stored at either -20 degrees C or at 37 degrees C/100% humidity. Nucleic acids were extracted at baseline and after 1, 2, 8 and 16 weeks of storage and were amplified and sequenced using an in-house RT-nested PCR method or the ViroSeq assay. RESULTS: HIV-1 pol was successfully amplified in all DBS/DPS at baseline and in those stored for up to 16 weeks at -20 degrees C by the in-house assay. In contrast, amplification was rapidly lost during storage at 37 degrees C/100% humidity with only 6/6 and 4/6 DBS specimens amplifiable by the in-house assay at weeks 1 and 2, respectively. Similarly, only two DPS stored at 37 degrees C/100% humidity were amplified by the in-house assay at week 1. CONCLUSIONS: We show that resistance testing from DBS and DPS is severely compromised after 2 and 1 weeks of storage at 37 degrees C/100% humidity with desiccant, respectively. These findings underscore the importance of temperature and humidity for the efficient genotyping of HIV-1 from DBS and DPS, and reiterate the need to rapidly transport specimens from collection sites to locations that have appropriate storage conditions such as -20 degrees C.


Assuntos
Sangue/virologia , Dessecação , Farmacorresistência Viral , HIV-1/genética , Plasma/virologia , Manejo de Espécimes/métodos , Genótipo , HIV-1/isolamento & purificação , Humanos , Umidade , Reação em Cadeia da Polimerase/métodos , RNA Viral/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Temperatura , Produtos do Gene pol do Vírus da Imunodeficiência Humana/genética
17.
J Clin Microbiol ; 46(9): 2945-9, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18614660

RESUMO

Collecting whole blood on filter paper simplifies the processing, transport, and storage of specimens used for the diagnosis of human immunodeficiency virus type 1 (HIV-1) and other tests. Specimens may be collected in tropical or rural areas with minimal facilities for handling specimens. To compare simulated tropical conditions with freezer storage, we examined the stability of HIV-1 DNA in dried blood spots (DBS) stored in humid heat and at -20 degrees C. DBS were created by spotting 50-microl aliquots of whole blood on 903 filter paper. DNA was extracted from DBS at baseline and after 2, 6, or 12 months of storage at -20 degrees C or at 37 degrees C with approximately 85% humidity. The DNA was tested undiluted or diluted using the Amplicor HIV-1 DNA PCR (Roche), version 1.5. Each reaction was scored positive, negative, or indeterminate based on optical density. Results were compared between storage conditions and over time. A total of 1,832 reactions from 916 DBS were analyzed, including 100 DBS at baseline, 418 stored at -20 degrees C, and 398 stored at 37 degrees C. A chi-square test showed fewer positive reactions for DBS stored at 37 degrees C (55%) than for those stored at -20 degrees C (78%) (P < 0.0001). Samples stored at -20 degrees C showed little change in the probability of detection of HIV-1 DNA over time; the odds ratio (OR) was 0.93 after storage for 1 year. Samples stored at 37 degrees C demonstrated a significant change in detection at 1 year (OR, 0.29). We conclude that exposure of DBS to 37 degrees C and high humidity impaired the recovery of HIV-1 DNA from DBS, whereas DNA recovery was preserved when DBS were stored frozen.


Assuntos
Criopreservação , DNA Viral/genética , HIV-1/genética , Manejo de Espécimes , Temperatura Alta , Humanos , Umidade
18.
Virology ; 369(1): 55-68, 2007 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-17716703

RESUMO

Human cytomegalovirus (HCMV) and human immunodeficiency virus type-1 (HIV-1) infect the female genital tract. A human cervical explant model was developed to study single and dual infection by these viruses in the genital compartment. An HCMV strain expressing green fluorescent protein, and two clinical HCMV strains produced peak viral DNA copies at 14 to 21 days post-infection. Peak levels of HIV-1(Ba-L) p24 antigen occurred at 7 days post-infection. HIV-1(Ba-L) appeared to enhance HCMV in co-infected tissues. Singly and dually infected explants produced increased levels of cytokines IL-6, IL-8, and GRO-alpha in culture supernatants. Immunohistochemical and flow cytometric analysis showed HCMV infection of leukocytes with the phenotype CD45+/CD1a+/CD14+/HLA-DR+ but not stromal or endothelial cells. Cells expressing both GFP and HIV-1 p24 antigen were detected in co-infected tissues. The cervical explants provide an ex vivo human model for examining mechanisms of virus-virus interaction and pathogenesis in clinically relevant tissue.


Assuntos
Colo do Útero/virologia , Infecções por Citomegalovirus/virologia , Citomegalovirus/crescimento & desenvolvimento , Infecções por HIV/virologia , HIV-1/crescimento & desenvolvimento , Quimiocina CXCL1/análise , Meios de Cultura/química , Células Endoteliais/virologia , Feminino , Genes Reporter , Proteínas de Fluorescência Verde/biossíntese , Proteínas de Fluorescência Verde/genética , Proteína do Núcleo p24 do HIV/biossíntese , Humanos , Interleucina-6/análise , Interleucina-8/análise , Leucócitos/virologia , Técnicas de Cultura de Órgãos , Células Estromais/virologia
19.
J Clin Microbiol ; 45(6): 1723-7, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17409210

RESUMO

Viral load testing for cytomegalovirus (CMV) has become the standard for the diagnosis of infection and monitoring of therapy at many transplant centers. However, no viral load test has been approved by the FDA. Therefore, many laboratories rely on laboratory-developed assays. This study evaluated the performance characteristics of two real-time PCR tests developed using the artus CMV analyte-specific reagents (ASRs). One version is distributed by Abbott Molecular and the other by QIAGEN. For plasma specimens, the Abbott test had a limit of detection of 2.3 log10 copies/ml and a linear range up to at least 6.0 log10 copies/ml. Comparison of plasma viral loads using the Abbott test and the Roche Amplicor Monitor test showed a mean difference of -0.012 log10 copies/ml. In addition, the Abbott test viral loads correlated with the Digene Hybrid Capture assay ratios. Viral loads obtained from plasma specimens tested by the Abbott and QIAGEN tests were in very close agreement (mean difference, 0.144 log10 copies/ml). When the QIAGEN test was evaluated with the QIAGEN, MagNA Pure, and easyMAG extraction methods, the viral loads for all three methods were within 0.370 log10 copies/ml. Thus, there is good agreement between viral loads obtained by the different tests using the same extraction method or by the same test using different extraction methods. The availability of real-time PCR ASRs provides additional reagents that can be used for CMV viral load testing.


Assuntos
Citomegalovirus/isolamento & purificação , DNA Viral/sangue , Indicadores e Reagentes/normas , Reação em Cadeia da Polimerase/métodos , Kit de Reagentes para Diagnóstico , Carga Viral , Citomegalovirus/genética , Infecções por Citomegalovirus/diagnóstico , Infecções por Citomegalovirus/virologia , DNA Viral/isolamento & purificação , Humanos , Reação em Cadeia da Polimerase/normas , Kit de Reagentes para Diagnóstico/normas , Reprodutibilidade dos Testes , Carga Viral/normas
20.
J Clin Microbiol ; 45(2): 517-21, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17166967

RESUMO

Dried blood spots (DBS) are simpler to prepare, store, and transport than plasma or serum and may represent a good alternative for drug resistance genotyping, particularly in resource-limited settings. However, the utility of DBS for drug resistance testing is unknown. We investigated the efficiency of amplification of large human immunodeficiency virus type 1 (HIV-1) pol fragments (1,023 bp) from DBS stored at different temperatures, the type of amplified product(s) (RNA and/or DNA), and the similarity between plasma and DBS sequences. We evaluated two matched plasma/DBS panels stored for 5 to 6 years at several temperatures and 40 plasma/DBS specimens collected from untreated persons in Cameroon and stored for 2 to 3 years at -20 degrees C. The amplification of HIV-1 pol was done using an in-house reverse transcriptase-nested PCR assay. Reactions were done with and without reverse transcription to evaluate the contribution of HIV DNA to pol sequences from DBS. Amplification was successful for the DBS samples stored for 5 to 6 years at -20 degrees C or at -70 degrees C but not for those stored at room temperature. Thirty-seven of the 40 (92.5%) DBS from Cameroon were amplifiable, including 8/11 (72.7%) with plasma virus loads of <10,000 RNA copies/ml and all 29 with plasma virus loads of >10,000. Proviral DNA contributed significantly to DBS sequences in 24 of the 37 (65%) specimens from Cameroon. The overall similarity between plasma and DBS sequences was 98.1%. Our results demonstrate the feasibility of DBS for drug resistance testing and indicate that -20 degrees C is a suitable temperature for long-term storage of DBS. The amplification of proviral DNA from DBS highlights the need for a wider evaluation of the concordance of resistance genotypes between plasma and DBS.


Assuntos
Coleta de Amostras Sanguíneas/métodos , Farmacorresistência Viral/genética , HIV-1/efeitos dos fármacos , DNA Viral/análise , DNA Viral/genética , Infecções por HIV/virologia , Protease de HIV/genética , Transcriptase Reversa do HIV/genética , HIV-1/enzimologia , HIV-1/genética , Humanos , Testes de Sensibilidade Microbiana/métodos , Dados de Sequência Molecular , Mutação , RNA Viral/sangue , RNA Viral/isolamento & purificação , Análise de Sequência de DNA
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA