Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Environ Qual ; 43(1): 349-57, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25602569

RESUMO

The dioxin-degrading bacterium strain NSYSU (NSYSU strain) has been isolated from dioxin-contaminated soil by selective enrichment techniques. In the present study, the NSYSU strain was investigated for its capability to biodegrade polychlorinated dibenzo--dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) under aerobic and anaerobic conditions. High-resolution gas chromatography-mass spectrometry and a chemically activated luciferase gene expression bioassay were performed to determine the presence of dioxin compounds. The results indicate that the NSYSU strain could degrade PCDDs and PCDFs under anaerobic conditions in liquid cultures. The main intermediates of the dechlorination process were identified. The results of the bioreactor test indicate that the NSYSU strain could also degrade PCDDs and PCDFs effectively in soil slurries under aerobic conditions. Results from the bioreactor experiment show that approximately 98 and 97% of octachlorodibenzofuran and OCDD were degraded, respectively. The dioxin concentrations in soil slurry decreased from 5823 to 1198 pg toxic equivalency g, resulting in total dioxin removal of 79%. These first findings suggest that the NSYSU strain has the potential to be an effective tool for the bioremediation of soils contaminated with highly recalcitrant organic compounds.

3.
J Chromatogr A ; 932(1-2): 97-105, 2001 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-11695873

RESUMO

A side-chain liquid crystalline polysiloxane polymer (PS3DBDE1) with high purity and high isotropic transition temperature served as a stationary phase in an attempt to chromatographize the dioxin/furan compounds. The polymer was coated on the inner surface of a 0.25 mm I.D. capillary column by using the static coating method, forming a film with a thickness of df approximately 0.25 microm. A commercial standard solution (US EPA 1613 standard solution 1613CS4) containing polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) was used to test the chromatographic behavior of the laboratory-made capillary column. Two commercial capillary columns HP-5MS (Hewlett-Packard) and RTX-5MS (RTX) were chosen to compare their chromatographic behavior. The results show that by the use of PS3DBDE1 the isomeric pair compounds 1,2,3,4-TeCDD vs. 2,3,7,8-TeCDD and 1,2,3,4,7,8-HxCDD vs. 1,2,3,6,7,8-HxCDD and the same substituted-chlorine number compounds 1,2,3,4,6,7,8-HpCDF vs. 1,2.3,4,6,7,8-HpCDD and 1,2,3,4,6,7,8,9-OCDD vs. 1,2,3,4,6,7,8,9-OCDF had higher resolution than HP-5MS and RTX-5MS as suggested by the column makers.


Assuntos
Cromatografia Gasosa/instrumentação , Dioxinas/isolamento & purificação , Furanos/isolamento & purificação , Siloxanas/química , Cromatografia Gasosa/métodos , Microscopia Eletrônica de Varredura
4.
Anal Chem ; 70(19): 4094-9, 1998 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-21651246

RESUMO

Two new and high-purity all-hydrocarbon side-chain liquid crystalline polysiloxane polymers were synthesized by grafting all-hydrocarbon liquid crystal monomers onto a polymethylhydrosiloxane backbone. The two polysiloxane polymers show both smectic B and E mesophases which were characterized by (differential scanning calorimetry and X-ray analysis. As stationary phases, these liquid crystalline polysiloxane polymers were coated on the inner surface of a capillary column (i.d. = 0.32 mm, film thickness d(f) ≈ 0.25 µm) using the static coating method. The capillary column was installed on a GC/MS instrument. We used a standard commercial mixture of 21 species of polynuclear aromatic hydrocarbons (purchased from Supelco Co. and Merck Co.) to test the chromatographic behavior of the coated stationary phase. Test results of the isomeric pair compounds show a better separation resolution than identical tests using the commercial HP-5 capillary column, which is a standard and state-of-the-art analytical tool for the chromatographic resolution of PAHs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA