Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 46(12): 1500-1508, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37885375

RESUMO

BACKGROUND: Remote monitoring is recommended for patients with implantable cardiac monitors (ICMs), but compared to other cardiac implantable devices, ICMs are less accurate and transmit a higher number of alerts. OBJECTIVE: The aim of this study was to investigate the predictors of false-positive (FP) arrhythmic alerts in patients with unexplained syncope who were implanted with ICM and followed by an automatic remote monitoring system. METHODS: We retrospectively evaluated all consecutive patients who received a long-sensing vector ICM for unexplained syncope between January 2019 to September 2021 at our Syncope Unit. The primary endpoint was the incidence of the first FP episode. The secondary endpoints included assessing the incidence of FP episodes for all types of algorhythms and indentifying the reasons for the misdetection of these episodes. RESULTS: Among 105 patients (44.8% males, median age 51 years), 51 (48.6%) transmitted at least one FP alert during a median follow-up of 301 days. The presence of pre-ventricular complexes (PVCs) on the resting electrocardiogram was the only clinical characteristic associated with an increased risk of FP alerts (adjusted Hazard ratio [HR] 5.76 [2.66-12.4], p = 0.010). The other significant device-related variables were a low-frequency filter at 0.05 Hz versus the default 0.5 Hz (adjusted HR 3.82 [1.38-10.5], p = 0.010) and the R-wave amplitude (adjusted HR 0.35 [0.13-0.99], p = 0.049). CONCLUSION: Patients who have PVCs are at higher risk of inappropriate ICM activations. To reduce the occurrence of FP alerts, it may be beneficial to target a large R-wave amplitude during device insertion and avoid programming a low-frequency filter at 0.05 Hz.


Assuntos
Arritmias Cardíacas , Eletrocardiografia , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/complicações , Síncope/diagnóstico , Síncope/etiologia , Eletrocardiografia Ambulatorial
2.
Indian J Pediatr ; 80(3): 263-5, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22392265

RESUMO

Different minimally invasive methods have been proposed to treat renal manifestation of tuberous sclerosis complex (TSC), in order to preserve kidney parenchyma and avoid nephrectomy. The case of a boy with bleeding giant angiomyolipoma treated by selective arterial embolization is discussed. The extensive renal lesions resulted significantly decreased, with resolution of arterial hypertension and abdominal symptoms. Differential renal function increased from 26.6% to 32.6%. Renal involvement in TSC requires careful parenchymal-sparing procedures. Selective embolization of the main renal lesions should be considered as first line therapy.


Assuntos
Angiomiolipoma/terapia , Embolização Terapêutica/métodos , Neoplasias Renais/terapia , Esclerose Tuberosa/terapia , Adolescente , Angiomiolipoma/diagnóstico , Humanos , Neoplasias Renais/diagnóstico , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA