Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Int J Clin Pharmacol Ther ; 49(8): 525-30, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21781653

RESUMO

OBJECTIVE: To compare the rate and extent of absorption of two sildenafil tablet formulations (Tonafil®, T.O. Chemicals (1979) Ltd., Thailand as a test formulation and Viagra®, Pfizer Pty Limited., Australia as a reference formulation) in healthy Thai male volunteers after single-dose administration under fasting condition. METHODS: A randomized crossover study with a washout period of 2 weeks was conducted in 20 healthy Thai male volunteers. The volunteers received either 100 mg of the reference or test formulation. Blood samples were collected at 0, 0.16, 0.33, 0.67, 1, 1.5, 2, 2.5, 4, 6, 9 and 12 h after drug administration. The plasma sildenafil concentrations were determined using a validated high performance liquid chromatography method. The pharmacokinetic parameters of sildenafil were calculated from the observed plasma concentration-time profiles by using a non-compartmental model. RESULTS AND CONCLUSIONS: The geometric means, C(max), of the reference and the test formulations were 696.42 and 734.06 ng/ml. The mean values of the AUC(0-t) and AUC(0-inf) of the test formulation were 2,073.03 and 2,237.37 ng × h/ml, while those of the reference formulation were 1,950.26 and 2,078.06 ng × h/ml. The geometric mean ratios (%) and 90% confidence intervals (CI) of the test and reference products for the log transformed C(max), AUC(0-t) and AUC(0-inf) of sildenafil were 105.40% (95.0 - 116.95%), 106.30% (99.74 - 113.28%) and 107.67% (100.83 - 116.48%). These values were within 80 to 125% of the US-FDA and the Thai-FDA criteria and therefore it can be concluded that the test formulation was bioequivalent to the reference formulation both in terms of rate and extent of absorption after single-dose administration under fasting condition.


Assuntos
Modelos Biológicos , Inibidores da Fosfodiesterase 5/farmacocinética , Piperazinas/farmacocinética , Sulfonas/farmacocinética , Adolescente , Adulto , Área Sob a Curva , Disponibilidade Biológica , Cromatografia Líquida de Alta Pressão , Estudos Cross-Over , Método Duplo-Cego , Humanos , Masculino , Pessoa de Meia-Idade , Inibidores da Fosfodiesterase 5/administração & dosagem , Piperazinas/administração & dosagem , Purinas/administração & dosagem , Purinas/farmacocinética , Citrato de Sildenafila , Sulfonas/administração & dosagem , Comprimidos , Tailândia , Equivalência Terapêutica , Adulto Jovem
2.
Int J Clin Pharmacol Ther ; 48(9): 614-20, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20860915

RESUMO

OBJECTIVES: To compare the bioavailability of two risperidone orodispersible tablet products, Risperidone 1 mg Mouth dissolving tablet, Ranbaxy (Malaysia) Sdn. Bhd., Malaysia, as a test product and Risperdal 1 mg Quicklet, Janssen Ortho LLC, Gurabo, Puerto Rico, as a reference product, in healthy male volunteers under fasting condition. MATERIALS AND METHODS: A randomized, 2-treatment, 2-period, 2-sequence, single dose, crossover with a washout period of 2 weeks, was conducted in 24 healthy Thai male volunteers. Blood samples were collected at 0, 0.25, 0.5, 0.75, 1, 1.25, 1.5, 1.75, 2, 2.5, 3, 3.5, 4, 5, 6, 8, 10, 12, 24, 36, 48, 72 and 96 h following drug administration. Plasma concentrations of risperidone and 9-hydroxyrisperidone were determined using a validated LC-MS-MS method. The pharmacokinetic parameters of risperidone and 9-hydroxyrisperidone were determined using a non-compartmental model. RESULTS: The geometric means ratios (%) and 90% confidence interval (CI) of the test and reference products for the log-transformed pharmacokinetic parameters, Cmax, AUC0-t and AUC0-inf of risperidone were 104.49 % (92.79% - 117.66%), 100.96 % (92.15% - 110.61 %) and 97.99 % (90.72% - 105.85%). The 90% CI of geometric means ratios of the test and reference products for the log-transformed pharmacokinetic parameters, Cmax, AUC0-t and AUC0-inf of 9-hydroxyrisperidone were 97.00%, 96.97% and 97.49%. CONCLUSIONS: The 90% CI for the geometric means ratios (test/reference) of the log-trasformed Cmax, AUC0-t and AUC0-inf of risperidone and its major active metabolite were within the bioequivalence acceptance criteria of 80% - 125% of the US-FDA.


Assuntos
Antipsicóticos/farmacocinética , Risperidona/farmacocinética , Adulto , Área Sob a Curva , Disponibilidade Biológica , Estudos Cross-Over , Humanos , Masculino , Comprimidos , Equivalência Terapêutica , Adulto Jovem
3.
Int J Clin Pharmacol Ther ; 47(10): 638-42, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19825327

RESUMO

OBJECTIVES: To compare the bioavailability of two meloxicam tablet formulations (MEL-OD, Zydus Cadila Healthcare Limited, India, as a test formulation and Mobic, Boehringer Ingelheim International GmbH, Germany, as a reference formulation) in healthy Thai male volunteers under fasting condition. MATERIALS AND METHODS: A randomized, 2-treatment, 2-period, 2-sequence, single dose, crossover with a washout period of 2 weeks, was conducted in 26 healthy Thai male volunteers. Blood samples were collected 0, 1, 2, 3, 3.5, 4, 4.5, 5, 5.5, 6, 7, 8, 10, 12, 24, 36, 48, 72 and 96 h post dose. Plasma concentrations of meloxicam were determined using a validated HPLC method. The pharmacokinetic parameters of meloxicam were determined using a non-compartmental model. RESULTS: The mean Cmax was 1,027.32 +/- 251.91 and 1,151.89 +/- 282.58 ng/ml while the mean AUC0-t was 34,024.31 +/- 11,811.68 and 35,137.66 +/- 11,970.47 ng x h/ml for the test and reference formulation, respectively. In addition, the mean AUC0-infinity for test formulation was 37,241.44 +/- 14,888.85 ng x h/ml and for the reference formulation was 39,541.04 +/- 16,624.64 ng x h/ml. The median tmax for the test and reference formulation was 4.50 (range 2.00 - 12.00) and 4.50 (range 3.00 - 10.00), respectively. The geometric means (90% confidence intervals) of the ratio for the log-transformed pharmacokinetic parameters, Cmax, AUC0-t and AUC0-inf were 0.8919 (82.58 - 96.32%), 0.9697 (89.46 - 105.10%) and 0.9525 (87.68 - 103.47%), respectively. CONCLUSIONS: It can be concluded that two meloxicam tablet formulations are bioequivalent both in term of rate and extent of absorption after single-dose administration under fasting condition.


Assuntos
Anti-Inflamatórios não Esteroides/farmacocinética , Tiazinas/farmacocinética , Tiazóis/farmacocinética , Adolescente , Adulto , Anti-Inflamatórios não Esteroides/administração & dosagem , Área Sob a Curva , Disponibilidade Biológica , Cromatografia Líquida de Alta Pressão , Estudos Cross-Over , Humanos , Masculino , Meloxicam , Comprimidos , Tailândia , Equivalência Terapêutica , Tiazinas/administração & dosagem , Tiazóis/administração & dosagem , Adulto Jovem
4.
Int J Clin Pharmacol Ther ; 46(3): 151-6, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18397687

RESUMO

OBJECTIVE: To compare the bioavailability of two sertraline tablet (50 mg) formulations (Serlift from Ranbaxy Laboratories Ltd., Gurgaon Haryana, India, as a test formulation and Zoloft from Pfizer Australia Pty Ltd., West Ryde, New South Wales, Australia, as a reference formulation) in 24 healthy Thai male volunteers under fasting condition. MATERIALS AND METHODS: A randomized, 2-treatment, 2-period, 2-sequence, single-dose, crossover study with a washout period of 3 weeks, was conducted in 24 healthy Thai male volunteers. Blood samples were collected at 0, 1, 2, 3, 4, 5, 6, 7, 8, 10, 12, 24, 36, 48, 72, 96 and 120 hours following drug administration. Plasma concentrations of sertraline were determined using validated LC-MS/MS method. Noncompartmental pharmacokinetics and statistical analyses were performed using SAS software for Windows, release 9.1 (SAS Institute Inc., Cary, NC, USA). RESULTS: The ratio of least square means and the 90% confidence intervals (CI) of the log-transformed data were 0.9950 (0.9111-1.0866) for Cmax, 1.0153 (0.9576-1.0764) for AUC(0-t) and 1.0110 (0.9510-1.0747) for AUC(0-infinity). In addition, the median tmax values for the test and reference formulations were similar (5.00 h). The 90% CI for Cmax, AUC(0-t) and AUC(0-infinity) were within the 0.8-1.25 interval of the US-FDA. CONCLUSIONS: The test formulation (Serlift, Ranbaxy Laboratories Ltd., Gurgaon, Haryana, India) is bioequivalent to the reference formulation (Zoloft, Pfizer Australia Pty Ltd., West Ryde, New South Wales, Australia) both in terms of rate and extent of absorption after single-dose administration under fasting condition.


Assuntos
Antidepressivos/farmacocinética , Sertralina/farmacocinética , Adulto , Antidepressivos/sangue , Área Sob a Curva , Disponibilidade Biológica , Química Farmacêutica , Estudos Cross-Over , Meia-Vida , Humanos , Masculino , Taxa de Depuração Metabólica , Sertralina/sangue , Tailândia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA