1.
Sci Rep ; 10(1): 7725, 2020 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-32382124

RESUMO

Cardiac magnetic resonance (MR) imaging is one of the most rigorous form of imaging to assess cardiac function in vivo. Strain analysis allows comprehensive assessment of diastolic myocardial function, which is not indicated by measuring systolic functional parameters using with a normal cine imaging module. Due to the small heart size in mice, it is not possible to perform proper tagged imaging to assess strain. Here, we developed a novel deep learning approach for automated quantification of strain from cardiac cine MR images. Our framework starts by an accurate localization of the LV blood pool center-point using a fully convolutional neural network (FCN) architecture. Then, a region of interest (ROI) that contains the LV is extracted from all heart sections. The extracted ROIs are used for the segmentation of the LV cavity and myocardium via a novel FCN architecture. For strain analysis, we developed a Laplace-based approach to track the LV wall points by solving the Laplace equation between the LV contours of each two successive image frames over the cardiac cycle. Following tracking, the strain estimation is performed using the Lagrangian-based approach. This new automated system for strain analysis was validated by comparing the outcome of these analysis with the tagged MR images from the same mice. There were no significant differences between the strain data obtained from our algorithm using cine compared to tagged MR imaging. Furthermore, we demonstrated that our new algorithm can determine the strain differences between normal and diseased hearts.


Assuntos
Cardiopatias/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Algoritmos , Animais , Coração/fisiopatologia , Cardiopatias/fisiopatologia , Ventrículos do Coração/patologia , Humanos , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Camundongos , Redes Neurais de Computação
2.
Med Eng Phys ; 33(10): 1193-202, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21680224

RESUMO

BACKGROUND: Historically, single port valveless pneumatic blood pumps have had a high incidence of thrombus formation due to areas of blood stagnation and hemolysis due to areas of high shear stress. METHODS: To ensure minimal hemolysis and favorable blood washing characteristics, particle image velocimetry (PIV) and computational fluid dynamics (CFD) were used to evaluate the design of a new single port, valveless counterpulsation device (Symphony). The Symphony design was tested in 6-h acute (n=8), 5-day (n=8) and 30-day (n=2) chronic experiments in a calf model (Jersey, 76 kg). Venous blood samples were collected during acute (hourly) and chronic (weekly) time courses to analyze for temporal changes in biochemical markers and quantify plasma free hemoglobin. At the end of the study, animals were euthanized and the Symphony and end-organs (brain, liver, kidney, lungs, heart, and spleen) were examined for thrombus formations. RESULTS: Both the PIV and the CFD showed the development of a strong moving vortex during filling phase and that blood exited the Symphony uniformly from all areas during ejection phase. The laminar shear stresses estimated by CFD remained well below the hemolysis threshold of 400 Pa inside the Symphony throughout filling and ejection phases. No areas of persistent blood stagnation or flow separation were observed. The maximum plasma free hemoglobin (<10mg/dl), average platelet count (pre-implant = 473 ± 56 K/µl and post-implant = 331 ± 62 K/µl), and average hematocrit (pre-implant = 31 ± 2% and post-implant = 29 ± 2%) were normal at all measured time-points for each test animal in acute and chronic experiments. There were no changes in measures of hepatic function (ALP, ALT) or renal function (creatinine) from pre-Symphony implantation values. The necropsy examination showed no signs of thrombus formation in the Symphony or end organs. CONCLUSIONS: These data suggest that the designed Symphony has good washing characteristics without persistent areas of blood stagnation sites during the entire pump cycle, and has a low risk of hemolysis and thrombus formations.


Assuntos
Simulação por Computador , Contrapulsação/instrumentação , Hidrodinâmica , Reologia , Animais , Órgãos Artificiais , Bovinos , Contrapulsação/efeitos adversos , Hemólise , Masculino , Teste de Materiais , Reprodutibilidade dos Testes , Estresse Mecânico , Trombose/etiologia , Fatores de Tempo
3.
Conf Proc IEEE Eng Med Biol Soc ; 2004: 3761-4, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-17271113

RESUMO

Alternative therapies for treating heart failure patients are being explored to provide effective options for patients with progressive heart failure. Cardiac assist devices that promote myocardial recovery may be a potential solution. Ventricular assist devices (VAD) have demonstrated long-term efficacy and intraaortic balloon pumps (IABP) have shown short-term successes. In this paper, testing of a hybrid counterpulsation device (CPD) that couples the attributes of device longevity (VAD) with less invasive surgery (IABP) is presented. Hemodynamic and ventricular pressure-volume responses to a 40 ml CPD and 40 ml IABP were evaluated in vitro in an adult mock circulation and in vivo in a large animal heart failure model. The CPD is a flexing diaphragm ventricle with a controlled stroke volume up to 85 cc through a single, valveless cannula. In this study, the CPD was cannulated to the brachiocephalic artery to provide 40 ml of counterpulsation support. The CPD effectively provided diastolic augmentation increasing coronary flow and afterload reduction. These results were comparable to IABP. These preliminary studies suggest that CPD may be an effective therapy for treating patients with early stage heart failure.

4.
Conf Proc IEEE Eng Med Biol Soc ; 2004: 3773-6, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-17271116

RESUMO

Ventricular assist devices (VADs) have been used successfully as a bridge to transplant in heart failure patients by unloading ventricular volume and restoring the circulation. An artificial vasculature device (AVD) that may better facilitate myocardial recovery than VAD by controlling the afterload seen by the ejecting heart is being developed. The AVD concept is to enable any user-defined input impedance (IM) with resistance (R) and compliance (C) components. In this study, a pulse duplicator was used to test the efficacy of the AVD concept for two control strategies in an adult mock circulation: (1) R-C in series and (2) 2-element Windkessel (R-C in parallel) using instantaneous impedance position control (IIPC) to maintain a desired value or profile of R and C. In vitro experiments were performed and the resulting cardiovascular pressures, volumes, flows, and the afterload (R and C) seen by the LV during ejection for simulated cardiac failure were recorded and analyzed. Our results indicate that setting the AVD to lower IM reduced LV volume and pressure, restored LV stroke volume, and increased coronary flow. The IIPC control algorithms are better suited to maintain any instantaneous IM or an IM profile, but are susceptible to measurement noise.