Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
1.
Rev Sci Instrum ; 95(4)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38563719

RESUMO

Laser polishing of material surfaces is a complex process depending on many variable parameters, such as, e.g., the properties of the used laser and optics (wavelength, pulse duration, fluence, and profile), as well as the processing (spot size, feed rate, and line or point overlap), and the thermodynamical properties of the material to be polished (heat capacity, heat conduction, etc.). For the successful laser polishing of any material, a systematic variation of all the process parameters is required to obtain satisfactorily polished surfaces with an appropriate set of parameters for the material of interest. In order to allow systematic studies of laser polishing processes, a new setup employing a highly stable nanosecond laser with an adjustable wavelength has been realized. The sample is located in a small high-vacuum chamber with the capability of introducing additional gases in a controlled manner, and the entire chamber is scanned in the beam to allow laser polishing of selected spots, lines, or larger areas. The setup is fully remote-controlled and allows in situ inspection of the initiated processes by means of a long-range microscope, electrical measurements, reflected laser light from the sample surface, and an analysis of the vacuum within the process chamber. The main properties of the setup will be presented, and some exemplary results on niobium and molybdenum metal samples will be discussed.

3.
Rev Sci Instrum ; 91(8): 083906, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32872899

RESUMO

We report on the functional capabilities of our field emission (FE) measurement systems. The samples are prepared and inserted under clean room conditions and can be precisely xyz-positioned, heat-treated, and investigated in different vacuum environments and temperatures. The FE scanning microscope is a unique microscope being used for the localization of FE sites with high lateral resolution by means of extraction voltage U(x, y) or emission current I(x, y) maps over the cathode area of 25 × 25 mm2 and measuring the FE properties of localized emission sites or individual emitters. In contrast, the integral measurement system with the luminescent screen provides real-time integral information about the distribution of emission sites over the whole cathode during long- and short-term current stability measurements, thus allowing us to investigate the properties of various materials and their applications. Commissioning results with the upgraded systems using a silicon emitter array and a point-type graphene emitter will be given to demonstrate that both FE measurement techniques are very useful for an improved understanding and tailoring of materials for applications. The results showed that point-type graphene emitters are more preferable for practical applications. Using simulation software, a suitable triode configuration for point emitters was designed, and a current transmission ratio of ∼100% was obtained. The FE current stability of graphene emitters at pressures >10-3 Pa can be improved by heating the cathode at 100 °C-300 °C for 1 min-30 min. Finally, point-type graphene film emitters were used for transmission-type x-ray sources, and their applications in imaging and fluorescence spectroscopy are presented.

4.
Anaerobe ; 43: 21-26, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27867083

RESUMO

The susceptibility trends for Bacteroides fragilis and related species against various antibiotics were determined using data from 3 years of surveillance (2010-2012) on 779 isolates referred by 7 medical centers. The antibiotic test panel included imipenem, ertapenem, meropenem, ampicillin-sulbactam, piperacillin-tazobactam, cefoxitin, clindamycin, moxifloxacin, tigecycline, linezolid, chloramphenicol and . MICs were determined using the agar dilution CLSI reference method. Carbapenem resistance remained low (range 1.1%-2.5%) and unchanged from 2008 to 9 through 2010-2012. Resistance also remained low to the beta-lactam/beta-lactamase inhibitor combinations (1.1%-4.4%). While resistance to clindamycin and moxifloxacin remained high; rates were lower for B. fragilis in 2010-12 (24% and 19% respectively) compared to the earlier time frame of 2008-9 (29% and 35% respectively for the earlier time frame). There were notable species and resistance associations which have been demonstrated previously. No resistance to metronidazole or chloramphenicol resistance was seen. These data demonstrate the continued variability in resistance among Bacteroides and Parabacteroides species, but do demonstrate that carbapenems and beta-lactam/beta-lactamase inhibitor combinations remain very active throughout the United States.


Assuntos
Anti-Infecciosos/farmacologia , Infecções por Bacteroides/tratamento farmacológico , Bacteroidetes/efeitos dos fármacos , Carbapenêmicos/farmacologia , Resistência Microbiana a Medicamentos , Inibidores de beta-Lactamases/farmacologia , Bacteroides/efeitos dos fármacos , Infecções por Bacteroides/microbiologia , Bacteroides fragilis/efeitos dos fármacos , Humanos , Testes de Sensibilidade Microbiana , Ácido Penicilânico/análogos & derivados , Ácido Penicilânico/farmacologia , Piperacilina/farmacologia , Combinação Piperacilina e Tazobactam , Estados Unidos
5.
J Antimicrob Chemother ; 71(1): 213-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26433782

RESUMO

OBJECTIVES: The aim of this study was to evaluate the susceptibilities of Clostridium difficile isolates to cadazolid, a novel antibiotic for the treatment of C. difficile infection. METHODS: Ribotyping and susceptibilities were determined for C. difficile isolates from a multicentre, double-blind, Phase 2 study of oral cadazolid in patients with C. difficile infection (NCT01222702, ClinicalTrials.gov; EudraCT 2010-020941-29, European Clinical Trials Database). Patients were randomized to receive 250, 500 or 1000 mg of cadazolid twice daily or 125 mg of vancomycin four times daily, for 10 days. MICs of cadazolid, vancomycin, fidaxomicin, linezolid and moxifloxacin were determined at baseline for all patients and post-baseline for patients with clinical failure or recurrence, using the agar dilution method. RESULTS: Seventy-eight of 84 patients had an evaluable toxigenic C. difficile isolate at baseline. The most frequent PCR ribotype was 027 (15.4%). Cadazolid MICs for baseline isolates (including epidemic strain 027) ranged from 0.06 to 0.25 mg/L. Baseline cadazolid MICs were similar to those of fidaxomicin and lower than those of vancomycin, linezolid and moxifloxacin. For each clinical outcome group (clinical cure, clinical failure, sustained clinical response and clinical failure or recurrence), the baseline cadazolid MIC range was 0.06-0.25 mg/L. Mean (min-max) cadazolid faecal concentration (µg/g) on day 5 was 884 (101-2710), 1706 (204-4230) and 3226 (1481-12 600) for the doses 250, 500 and 1000 mg, respectively. CONCLUSIONS: For all cadazolid doses, the faecal concentration was in excess of several thousand-fold the MIC90 for C. difficile. The MIC of cadazolid for all C. difficile isolates, including epidemic strains, was low and in the same narrow range regardless of treatment outcome.


Assuntos
Antibacterianos/administração & dosagem , Clostridioides difficile/efeitos dos fármacos , Infecções por Clostridium/tratamento farmacológico , Infecções por Clostridium/microbiologia , Oxazolidinonas/administração & dosagem , Vancomicina/administração & dosagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/farmacologia , Clostridioides difficile/classificação , Clostridioides difficile/genética , Clostridioides difficile/isolamento & purificação , Método Duplo-Cego , Feminino , Humanos , Masculino , Testes de Sensibilidade Microbiana , Pessoa de Meia-Idade , Oxazolidinonas/farmacologia , Ribotipagem , Vancomicina/farmacologia , Adulto Jovem
6.
Rev Sci Instrum ; 86(9): 093905, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26429455

RESUMO

The design and capabilities of a novel Quick scanning Extended X-ray Absorption Fine Structure (QEXAFS) monochromator are presented. The oscillatory movement of the crystal stage is realized by means of a unique open-loop driving scheme operating a direct drive torque motor. The entire drive mechanics are installed inside of a goniometer located on the atmospheric side of the vacuum chamber. This design allows remote adjustment of the oscillation frequency and spectral range, giving complete control of QEXAFS measurements. It also features a real step-scanning mode, which operates without a control loop to prevent induced vibrations. Equipped with Si(111) and Si(311) crystals on a single stage, it facilitates an energy range from 4.0 keV to 43 keV. Extended X-ray absorption fine structure spectra up to k = 14.4 Å(-1) have been acquired within 17 ms and X-ray absorption near edge structure spectra covering more than 200 eV within 10 ms. The achieved data quality is excellent as shown by the presented measurements.

7.
Rev Sci Instrum ; 86(4): 043307, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25933855

RESUMO

We have completed an ultra-high vacuum system for sensitive fast electron spectroscopy from cold cathodes in triode configuration under high electric fields E (<100 MV/m) and pulsed tunable laser illumination (3.5 ns, 10 Hz, hν = 0.5-5.9 eV, and 0.3-17 mJ). The cathodes are prepared and inserted under clean room conditions and can be precisely 3D-positioned, cooled or heated (77-400 K). Commissioning results with the upgraded system are presented. Field emission measurements with a W tip yielded an energy resolution of 14 meV at 4 eV pass energy and a precise determination of the emitter work function, size, and temperature. Photoemission spectroscopy of short electron bunches from a virgin and laser-ablated S-GaP crystal and quantum efficiency measurements revealed surface states, energy relaxation, and band structure effects. In conclusion, this novel system is ready now for the development and characterization of photo-induced field emission cathodes.

8.
Rev Sci Instrum ; 86(3): 035105, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25832273

RESUMO

A fast X-ray chopper capable of producing ms long X-ray pulses with a typical rise time of few µs was realized. It is ideally suited to investigate the temporal response of X-ray detectors with response times of the order of µs to ms, in particular, any kind of ionization chambers and large area photo diodes. The drive mechanism consists of a brushless DC motor and driver electronics from a common hard disk drive, keeping the cost at an absolute minimum. Due to its simple construction and small dimensions, this chopper operates at home lab based X-ray tubes and synchrotron radiation sources as well. The dynamics of the most important detectors used in time resolved X-ray absorption spectroscopy, namely, ionization chambers and Passivated Implanted Planar Silicon photodiodes, were investigated in detail. The results emphasize the applicability of this X-ray chopper.

9.
Nanoscale ; 7(11): 4978-83, 2015 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-25692478

RESUMO

Colourless solutions of blue light-emitting, water-soluble gold nanoclusters (AuNC) were synthesized from gold colloids under microwave irradiation using small organic molecules as ligands. Stabilized by 1,3,5-triaza-7-phosphaadamantane (TPA) or L-glutamine (GLU), fluorescence quantum yields up to 5% were obtained. AuNC are considered to be very promising for biological labelling, optoelectronic devices and light-emitting materials but the structure-property relationships have still not been fully clarified. To expand the knowledge about the AuNC apart from their fluorescent properties they were studied by X-ray absorption spectroscopy elucidating the oxidation state of the nanoclusters' gold atoms. Based on curve fitting of the XANES spectra in comparison to several gold references, optically transparent fluorescent AuNC are predicted to be ligand-stabilized Au5(+) species. Additionally, their near edge structure compared with analogous results of polynuclear clusters known from the literature discloses an increasing intensity of the feature close to the absorption edge with decreasing cluster size. As a result, a linear relationship between the cluster size and the X-ray absorption coefficient can be established for the first time.

10.
J Synchrotron Radiat ; 21(Pt 4): 819-26, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24971981

RESUMO

The layout and the characteristics of the hard X-ray beamline BL10 at the superconducting asymmetric wiggler at the 1.5 GeV Dortmund Electron Accelerator DELTA are described. This beamline is equipped with a Si(111) channel-cut monochromator and is dedicated to X-ray studies in the spectral range from ∼4 keV to ∼16 keV photon energy. There are two different endstations available. While X-ray absorption studies in different detection modes (transmission, fluorescence, reflectivity) can be performed on a designated table, a six-axis kappa diffractometer is installed for X-ray scattering and reflectivity experiments. Different detector set-ups are integrated into the beamline control software, i.e. gas-filled ionization chambers, different photodiodes, as well as a Pilatus 2D-detector are permanently available. The performance of the beamline is illustrated by high-quality X-ray absorption spectra from several reference compounds. First applications include temperature-dependent EXAFS experiments from liquid-nitrogen temperature in a bath cryostat up to ∼660 K by using a dedicated furnace. Besides transmission measurements, fluorescence detection for dilute sample systems as well as surface-sensitive reflection-mode experiments are presented.

11.
Mucosal Immunol ; 7(4): 983-94, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24399150

RESUMO

Human immunodeficiency virus-1 (HIV-1) infection disrupts the intestinal immune system, leading to microbial translocation and systemic immune activation. We investigated the impact of HIV-1 infection on the intestinal microbiome and its association with mucosal T-cell and dendritic cell (DC) frequency and activation, as well as with levels of systemic T-cell activation, inflammation, and microbial translocation. Bacterial 16S ribosomal DNA sequencing was performed on colon biopsies and fecal samples from subjects with chronic, untreated HIV-1 infection and uninfected control subjects. Colon biopsies of HIV-1-infected subjects had increased abundances of Proteobacteria and decreased abundances of Firmicutes compared with uninfected donors. Furthermore at the genus level, a significant increase in Prevotella and decrease in Bacteroides was observed in HIV-1-infected subjects, indicating a disruption in the Bacteroidetes bacterial community structure. This HIV-1-associated increase in Prevotella abundance was associated with increased numbers of activated colonic T cells and myeloid DCs. Principal coordinates analysis demonstrated an HIV-1-related change in the microbiome that was associated with increased mucosal cellular immune activation, microbial translocation, and blood T-cell activation. These observations suggest that an important relationship exists between altered mucosal bacterial communities and intestinal inflammation during chronic HIV-1 infection.


Assuntos
Endotoxemia/imunologia , Infecções por HIV/imunologia , HIV-1/imunologia , Imunidade , Mucosa Intestinal/imunologia , Mucosa Intestinal/microbiologia , Microbiota , Adulto , Biodiversidade , Biópsia , Índice de Massa Corporal , Contagem de Linfócito CD4 , Colo/imunologia , Colo/microbiologia , Colo/patologia , Dieta , Disbiose/imunologia , Feminino , Infecções por HIV/virologia , Humanos , Mucosa Intestinal/patologia , Ativação Linfocitária/imunologia , Masculino , Pessoa de Meia-Idade , Subpopulações de Linfócitos T/imunologia , Carga Viral , Adulto Jovem
12.
Rev Sci Instrum ; 84(5): 055104, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23742586

RESUMO

We realized an advanced apparatus for the investigation of emitted X-rays produced by peeling adhesive tape rolls under vacuum conditions. Two stepper motors can unwind and rewind a tape roll, and an additional roller with an optical encoder provides measurement and control of the tape speed. This way reproducible and consecutive experiments are feasible without having to change the tape or break the vacuum. The dependence of the X-ray emission on tape speed, gas pressure, type of adhesive tape, and detector angle has been investigated. The resulting spectra are continuous and span an X-ray energy range of typically 2-60 keV with high intensity. Furthermore, the new apparatus allows the in situ metalization of adhesive tape rolls by a gold sputter source. A significantly increased X-ray emission was observed for adhesive tapes with a metal coating. Thin metal foils have been placed between the tape and the detector, different K- and L-absorption edges could be measured. A considerable enhancement of the emission was achieved under the influence of the magnetic field of an NdFeB permanent magnet.

13.
Rev Sci Instrum ; 83(1): 013302, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22299940

RESUMO

We have constructed a new ultrahigh vacuum apparatus with a triode configuration for the systematic investigation of photo-induced field emission (PFE) from metallic or semiconducting cathodes. These are exposed to electric fields up to 400 MV∕m and laser irradiation by means of hole or mesh gates. Cathodes and gates are in situ exchangeable and adjustable with high precision to ensure a homogeneous extraction of electrons which are partially transmitted to the fixed electron spectrometer. Its hemispherical sector analyzer provides an energy resolution limit of 8 meV. The commissioning of the measurement system has been performed with a tungsten needle. Its temperature showed up in the high-energy tail of the electron spectrum, while its work function was derived from the spectral low-energy part combined with the integral current-voltage curve. First PFE measurements on B-doped Si-tip arrays yielded a small field emission current increase under green laser illumination. A shift and splitting of the energy spectra was observed which revealed different emission regimes as well as the photosensitivity of the cathode due to carrier excitation into the conduction band. For the full exploitation of the PFE system, a tunable laser over a wide eV-range is required.

14.
Anaerobe ; 17(4): 147-51, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21664469

RESUMO

The susceptibility trends for the species of the Bacteroides fragilis group against various antibiotics were determined using data from 4 years [2006-2009] on 1957 isolates referred by 8 medical centers participating in a National Survey for the Susceptibility of B. fragilis. The antibiotic test panel included doripenem, ertapenem, imipenem, meropenem, ampicillin:sulbactam, piperacillin:tazobactam, cefoxitin, clindamycin, moxifloxacin, tigecycline, chloramphenicol and metronidazole. MICs were determined using agar dilution methods following CLSI recommendations. Genetic analysis of isolates from 2008 with elevated MICs (>2 µg/mL) to one or more of the carbapenems to detect presence of the cfiA gene was performed using PCR methodology. The results showed an increase in the resistance rates to the ß-lactam antibiotics. High resistance rates were seen for clindamycin and moxifloxacin (as high as 60% for clindamycin and >80% for moxifloxacin), with relatively stable low resistance (5.4%) for tigecycline. For carbapenems, resistance in B. fragilis was 1.1%-2.5% in 2008-9. One isolate resistant to metronidazole (MIC 32 µg/mL) was observed as well as isolates with elevated MICs to chloramphenicol (16 µg/mL). Genetic analysis indicated that the cfiA gene was present in some but not all of the isolates with high MICs to the carbapenems. These data indicate that there continue to be changes in susceptibility over time, and that resistance can be seen among the carbapenems. High antibiotic resistance rates tend to be associated with specific species.


Assuntos
Bacteroides fragilis/efeitos dos fármacos , Bacteroides fragilis/genética , Carbapenêmicos/farmacologia , Antibacterianos/farmacologia , Proteínas de Bactérias/genética , Bacteroides fragilis/isolamento & purificação , Resistência Microbiana a Medicamentos , Genes Bacterianos , Humanos , Testes de Sensibilidade Microbiana/métodos , beta-Lactamases/genética
15.
J Appl Phys ; 110(11): 113527-1135275, 2011 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-22275772

RESUMO

The structure/property relationships of fluorochlorozirconate glass ceramics as a function of divalent and trivalent europium (Eu) co-doping and thermal processing have been investigated; the influence of doping ratio on the formation of barium chloride (BaCl(2)) nanocrystals therein was elucidated. X-ray absorption near-edge structure spectroscopy shows that the post-thermal annealing changes the Eu valence of the as-poured glass slightly, but during the melting process Eu(3+) is more strongly reduced to Eu(2+), in particular, when doped as a chloride instead of fluoride compound. The Eu(2+)-to-Eu(3+) doping ratio also plays a significant role in chemical equilibrium in the melt. X-ray diffraction measurements indicate that a higher Eu(2+) fraction leads to a BaCl(2) phase transition from hexagonal to orthorhombic structure at a lower temperature.

16.
Rev Sci Instrum ; 81(7): 073109, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20687707

RESUMO

A new monochromator setup for quick scanning x-ray absorption spectroscopy in the subsecond time regime is presented. Novel driving mechanics allow changing the energy range of the acquired spectra by remote control during data acquisition for the first time, thus dramatically increasing the flexibility and convenience of this method. Completely new experiments are feasible due to the fact that time resolution, edge energy, and energy range of the acquired spectra can be changed continuously within seconds without breaking the vacuum of the monochromator vessel and even without interrupting the measurements. The advanced mechanics are explained in detail and the performance is characterized with x-ray absorption spectra of pure metal foils. The energy scale was determined by a fast and accurate angular encoder system measuring the Bragg angle of the monochromator crystal with subarcsecond resolution. The Bragg angle range covered by the oscillating crystal can currently be changed from 0 degrees to 3.0 degrees within 20 s, while the mechanics are capable to move with frequencies of up to ca. 35 Hz, leading to ca. 14 ms/spectrum time resolution. A new software package allows performing programmed scan sequences, which enable the user to measure stepwise with alternating parameters in predefined time segments. Thus, e.g., switching between edges scanned with the same energy range is possible within one in situ experiment, while also the time resolution can be varied simultaneously. This progress makes the new system extremely user friendly and efficient to use for time resolved x-ray absorption spectroscopy at synchrotron radiation beamlines.


Assuntos
Dispositivos Ópticos , Espectroscopia por Absorção de Raios X/instrumentação , Fótons , Software , Fatores de Tempo
17.
Phys Chem Chem Phys ; 11(27): 5742-8, 2009 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-19842492

RESUMO

Upon lithium insertion in the pristine TiO2 anatase phase the theoretical maximum of LiTiO2 can be reached in crystallite sizes less than approximately 10 nm, whereas bulk compositions appear limited to Li(x) approximately 0.6TiO2 at room temperature. Both X-ray absorption spectroscopy (XAS) and ab initio calculations have been applied to probe the electronic structure of the newly formed LiTiO2 phase. These results indicate that a large majority of the Li-2s electrons reside at the Ti-3d(t2g)/4s hybridized site. About 10% of these electrons are transferred to non-localized states which makes this compound a good electronic conductor. Ionic conductivity is probed by nuclear magnetic resonance (NMR) relaxation experiments indicating relatively small hopping rates between the Li-ion sites in LiTiO2. Formation of the poor ionic-conducting LiTiO2 at the surface of the particles explains why micro-anatase Li(x)TiO2 is not able to reach the theoretical maximum capacity at room temperature, and why this theoretical maximum capacity reached in nano-sized materials cannot be (dis)charged at high rates.

18.
J Synchrotron Radiat ; 16(Pt 4): 443-54, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19535856

RESUMO

The calculation of reflection-mode grazing-incidence X-ray absorption spectra from single surfaces and (multi-)layered systems is studied here. In particular, the influence of the surface and interface roughness was investigated in detail. Simulations of grazing-incidence reflection-mode EXAFS spectra using a simple Fresnel theory neglecting any effect of roughness are compared with the Névot-Croce model and the elaborated distorted-wave Born approximation which both include surface and interface roughness. Data are presented for clean gold surfaces, where the strong influence of the surface roughness on the resulting spectra is demonstrated. Furthermore, in the case of layered systems, the influence of both the outer (air or vacuum side) surface roughness and the inner interface roughness on the reflection-mode EXAFS spectra is evaluated. The practical consequences of the observed correlations are discussed, and a quantitative data analysis of a copper sample that was oxidized in ambient air for several months is shown, including the evaluation of specular reflectivity profiles at fixed energy.

19.
Rev Sci Instrum ; 79(8): 083107, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19044336

RESUMO

New concepts for time-resolved x-ray absorption spectroscopy using the quick-extended x-ray absorption fine structure (QEXAFS) method are presented. QEXAFS is a powerful tool to gain structural information about, e.g., fast chemical reactions or phase transitions on a subsecond scale. This can be achieved with a monochromator design that employs a channel-cut crystal on a cam driven tilt table for rapid angular oscillations of the Bragg angle. A new angular encoder system and a new data acquisition were described and characterized that were applied to a QEXAFS monochromator to get spectra with a directly measured accurate energy scale. New electronics were designed to allow a fast acquisition of the Bragg angle values and the absorption data during the measurements simultaneously.

20.
Antimicrob Agents Chemother ; 51(5): 1649-55, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17283189

RESUMO

The susceptibility trends for the species of the Bacteroides fragilis group against various antibiotics from 1997 to 2004 were determined by using data for 5,225 isolates referred by 10 medical centers. The antibiotic test panel included ertapenem, imipenem, meropenem, ampicillin-sulbactam, piperacillin-tazobactam, cefoxitin, clindamycin, moxifloxacin, tigecycline, chloramphenicol, and metronidazole. From 1997 to 2004 there were decreases in the geometric mean (GM) MICs of imipenem, meropenem, piperacillin-tazobactam, and cefoxitin for many of the species within the group. B. distasonis showed the highest rates of resistance to most of the beta-lactams. B. fragilis, B. ovatus, and B. thetaiotaomicron showed significantly higher GM MICs and rates of resistance to clindamycin over time. The rate of resistance to moxifloxacin of B. vulgatus was very high (MIC range for the 8-year study period, 38% to 66%). B. fragilis, B. ovatus, and B. distasonis and other Bacteroides spp. exhibited significant increases in the rates of resistance to moxifloxacin over the 8 years. Resistance rates and GM MICs for tigecycline were low and stable during the 5-year period over which this agent was studied. All isolates were susceptible to chloramphenicol (MICs < 16 microg/ml). In 2002, one isolate resistant to metronidazole (MIC = 64 microg/ml) was noted. These data indicate changes in susceptibility over time; surprisingly, some antimicrobial agents are more active now than they were 5 years ago.


Assuntos
Antibacterianos/farmacologia , Bacteroides fragilis/efeitos dos fármacos , Bacteroides/efeitos dos fármacos , Farmacorresistência Bacteriana , Testes de Sensibilidade Microbiana , Fatores de Tempo , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA