Phys Med Biol ; 64(10): 105008, 2019 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-30965298

RESUMO

PURPOSE: To find comprehensive equations for the frequency-dependent MTF and DQE of photon counting detectors including the effect that the combination of crosstalk with an energy threshold is changing the pixel sensitivity profile and to compare the results with measurements. METHODS: The framework of probability-generating functions (PGF) is used to find a simple method to derive the MTF and the DQE directly from a Monte-Carlo model of the detection process. RESULTS: In combination with realistic model parameters for the detector, the method is used to predict the MTF and the DQE for different pixel sizes and thresholds. Particularly for small pixels, the modification of the sensitivity profile due to crosstalk substantially affects the frequency dependence of both quantities. CONCLUSION: The phenomenon of the pixel sensitivity profile, i.e. the fact that the choice of the threshold is affecting the detector sharpness, may play a substantial role in exploiting the full potential of photon counting detectors. The model compares well with measurements: with only two model parameters, the model can predict the MTF(f) and the DQE(f) for a wide range of thresholds.


Assuntos
Modelos Teóricos , Método de Monte Carlo , Fótons , Radiometria/instrumentação , Humanos , Razão Sinal-Ruído
2.
Invest Radiol ; 52(2): 81-86, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27518213

RESUMO

INTRODUCTION: Recent studies have shown a substantial reduction of radiation dose from computed tomography (CT) scans down to 0.1 mSv for lung cancer screening and cardiac examinations, when applying optimization techniques. Hence, CT localizer radiographs (LRs) might now be considered a significant contributor to the total dose of the CT examination. We investigated in our study the potential for reducing dose of the LRs by adapting the patient-specific acquisition parameters of the LR. MATERIALS AND METHODS: Localizer radiographs covering the lungs were acquired on 2 clinical scanners (64 slices, conventional detector [CD]; 96 slices, fully integrated detector [ID]) for 3 semianthropomorphic phantoms, representing a slim, a normal, and an obese adult. Starting at 120-kV tube voltage and 250-mA current were reduced until the image quality of the LR, and thereby the accuracy of the automatic exposure control was compromised; this was defined as a deviation of measured attenuation values in the center of the LR of more than 5% from the reference values measured at the highest tube voltage and current. Subsequent Monte Carlo calculations on anthropomorphic phantoms were performed to calculate organ and effective dose values for the respective optimal settings. In addition, effective dose values normalized to CTDIvol for tube voltages ranging from 60 to 160 kV were determined for the different combinations of phantom sizes, sexes, and LR views to evaluate dose efficiency. RESULTS: For the CD scanner, the optimal LR settings depended strongly on phantom size. Higher tube voltage and current were necessary for the larger phantoms. The ID scanner showed uncompromised LR quality for all phantoms using the lowest possible tube voltage-tube current combination of 80 kV and 20 mA. Depending on patient size and LR direction, effective dose values for the optimal settings ranged from 6 to 53 µSv and 3 to 11 µSv for the CD and ID scanner, respectively. For the example of an anterior-posterior LR on a normal patient, using the optimal settings instead of the standard settings on the ID scanner reduced LR dose from 53 µSv (120 kV, 30 mA) to 10 µSv (80 kV, 20 mA). The simulations for the different tube voltages show that effective dose and CTDIvol behave similarly for different views and patient sizes. However, the tube voltage level itself impacts the relationship between CTDIvol and effective dose, by up to a factor of 2. DISCUSSION: Dose from LRs may contribute significantly to the total effective dose of low-dose CT examinations such as lung cancer screening. Optimal LR settings can reduce LR dose substantially, but adaptations have to consider scanner characteristics, detector technology, and patient size. Thus, for low-dose CT examinations, such as cardiac examinations and lung cancer screening, LR optimization may result in a significant dose reduction and thereby in a substantial reduction of total dose.


Assuntos
Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Adulto , Humanos , Método de Monte Carlo
3.
Invest Radiol ; 51(4): 249-54, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26606552

RESUMO

OBJECTIVES: Spectral optimization of x-ray computed tomography (CT) has led to substantial radiation dose reduction in contrast-enhanced CT studies using standard iodinated contrast media. The purpose of this study was to analyze the potential for further dose reduction using high-atomic-number elements such as hafnium and tungsten. As in previous studies, spectra were determined for which the patient dose necessary to provide a given contrast-to-noise ratio (CNR) is minimized. MATERIALS AND METHODS: We used 2 different quasi-anthropomorphic phantoms representing the liver cross-section of a normal adult and an obese adult patient with the lateral widths of 360 and 460 mm and anterior-posterior heights of 200 and 300 mm, respectively. We simulated and measured on 2 different scanners with x-ray spectra from 80 to 140 kV and from 70 to 150 kV, respectively. We determined the contrast for iodine-, hafnium-, and tungsten-based contrast media, the noise, and 3-dimensional dose distributions at all available tube voltages by measurements and by simulations. The dose-weighted CNR was determined as optimization parameter. RESULTS: Simulations and measurements were in good agreement regarding their dependence on energy for all parameters investigated. Hafnium provided the best performance for normal and for obese patient phantoms, indicating a dose reduction potential of 30% for normal and 50% for obese patients at 120 kV compared with iodine; this advantage increased further with higher kV values. Dose-weighted CNR values for tungsten were always slightly below the hafnium results. Iodine proved to be the superior choice at voltage values of 80 kV and below. DISCUSSION: Hafnium and tungsten both seem to be candidates for contrast-medium-enhanced CT of normal and obese adult patients with strongly reduced radiation dose at unimpaired image quality. Computed tomography examinations of obese patients will decrease in dose for higher kV values.


Assuntos
Meios de Contraste/química , Doses de Radiação , Tomografia Computadorizada por Raios X , Háfnio/química , Humanos , Iodo/química , Fígado , Obesidade , Imagens de Fantasmas , Tungstênio/química
4.
Phys Med ; 31(4): 406-13, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25841299

RESUMO

PURPOSE: To investigate the dose saving potential of direct-converting CdTe photon-counting detector technology for dedicated breast CT. MATERIALS AND METHODS: We analyzed the modulation transfer function (MTF), the noise power spectrum (NPS) and the detective quantum efficiency (DQE) of two detector technologies, suitable for breast CT (BCT): a flat-panel energy-integrating detector with a 70 µm and a 208 µm thick gadolinium oxysulfide (GOS) and a 150 µm thick cesium iodide (CsI) scintillator and a photon-counting detector with a 1000 µm thick CdTe sensor. RESULTS: The measurements for GOS scintillator thicknesses of 70 µm and 208 µm delivered 10% pre-sampled MTF values of 6.6 mm(-1) and 3.2 mm(-1), and DQE(0) values of 23% and 61%. The 10% pre-sampled MTF value for the 150 µm thick CsI scintillator 6.9 mm(-1), and the DQE(0) value was 49%. The CdTe sensor reached a 10% pre-sampled MTF value of 8.5 mm(-1) and a DQE(0) value of 85%. CONCLUSION: The photon-counting CdTe detector technology allows for significant dose reduction compared to the energy-integrating scintillation detector technology used in BCT today. Our comparative evaluation indicates that a high potential dose saving may be possible for BCT by using CdTe detectors, without loss of spatial resolution.


Assuntos
Mama , Mamografia/instrumentação , Contagem de Cintilação/instrumentação , Compostos de Cádmio , Doses de Radiação , Razão Sinal-Ruído , Telúrio
5.
Phys Med ; 30(8): 925-33, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25288527

RESUMO

The estimation of patient dose using Monte Carlo (MC) simulations based on the available patient CT images is limited to the length of the scan. Software tools for dose estimation based on standard computational phantoms overcome this problem; however, they are limited with respect to taking individual patient anatomy into account. The purpose of this study was to generate whole-body patient models in order to take scattered radiation and over-scanning effects into account. Thorax examinations were performed on three physical anthropomorphic phantoms at tube voltages of 80 kV and 120 kV; absorbed dose was measured using thermoluminescence dosimeters (TLD). Whole-body voxel models were built as a combination of the acquired CT images appended by data taken from widely used anthropomorphic voxel phantoms. MC simulations were performed both for the CT image volumes alone and for the whole-body models. Measured and calculated dose distributions were compared for each TLD chip position; additionally, organ doses were determined. MC simulations based only on CT data underestimated dose by 8%-15% on average depending on patient size with highest underestimation values of 37% for the adult phantom at the caudal border of the image volume. The use of whole-body models substantially reduced these errors; measured and simulated results consistently agreed to better than 10%. This study demonstrates that combined whole-body models can provide three-dimensional dose distributions with improved accuracy. Using the presented concept should be of high interest for research studies which demand high accuracy, e.g. for dose optimization efforts.


Assuntos
Imagens de Fantasmas , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Algoritmos , Criança , Pré-Escolar , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Lactente , Recém-Nascido , Masculino , Radiografia Torácica/métodos , Reprodutibilidade dos Testes , Software , Dosimetria Termoluminescente/métodos , Imagem Corporal Total
6.
Phys Med Biol ; 59(19): 5691-706, 2014 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-25198916

RESUMO

The purpose of this study was to validate the use of a single shaped filter (SF) for computed tomography (CT) using variable source-to-filter distance (SFD) for the examination of different object diameters.A SF was designed by performing simulations with the purpose of achieving noise homogeneity in the reconstructed volume and dose reduction for arbitrary phantom diameters. This was accomplished by using a filter design method thats target is to achieve a homogeneous detector noise, but also uses a correction factor for the filtered back projection process. According to simulation results, a single SF designed for one of the largest phantom diameters meets the requirements for all diameters when SFD can be adjusted. To validate these results, a SF made of aluminium alloy was manufactured. Measurements were performed on a CT scanner with polymethyl methacrylate (PMMA) phantoms of diameters from 40-100 mm. The filter was positioned at SFDs ranging from 97-168 mm depending on the phantom diameter. Image quality was evaluated for the reconstructed volume by assessing CT value accuracy, noise homogeneity, contrast-to-noise ratio weighted by dose (CNRD) and spatial resolution. Furthermore, scatter distribution was determined with the use of a beam-stop phantom. Dose was measured for a PMMA phantom with a diameter of 100 mm using a calibrated ionization chamber.The application of a single SF at variable SFD led to improved noise uniformity and dose reduction: noise homogeneity was improved from 15% down to about 0%, and dose was reduced by about 37%. Furthermore, scatter dropped by about 32%, which led to reduced cupping artifacts and improved CT value accuracy. Spatial resolution and CNRD was not affected by the SF.By means of a single SF with variable SFD designed for CT, significant dose reduction can be achieved and image quality can be improved by reducing noise inhomogeneity as well as scatter-induced artifacts.


Assuntos
Artefatos , Filtração/métodos , Imagens de Fantasmas , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Calibragem , Simulação por Computador , Humanos , Polimetil Metacrilato/química , Doses de Radiação
7.
Radiology ; 273(1): 153-9, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24937693

RESUMO

PURPOSE: To determine the dose-length product (DLP)-effective dose (ED) (DLP/ED) conversion coefficient (k) tables for the lower extremities that can be used for calculating ED. MATERIALS AND METHODS: Dose calculations were performed on standard phantoms using a validated Monte Carlo calculation tool. Calculations were performed to obtain ED values for tube voltages from 80 kV to 140 kV in steps of 20 kV for the following examinations: hip (femur), knee, ankle, and computed tomographic (CT) angiography of the lower extremities. Values of the DLP were calculated by multiplying measured CT dose index values by the scan length; k values resulted as the quotients of the ED and DLP values. DLP/ED coefficients averaged over the range of voltage values and their standard deviations were determined for the given lower-extremity CT examinations for all age groups and for both sexes. RESULTS: Coefficients depend strongly on the phantom age and size, but little on the kilovolt value. In the case of the newborn, for example, k values were 0.0612, 0.0046, 0.0014, and 0.047 for hip, knee, ankle, and CT angiography, respectively, while in the case of the adult, these respective values were 0.0110, 0.0004, 0.0002, and 0.0062. A substantial difference up to 20% between coefficients in male and female phantoms was observed for CT angiographic examination. CONCLUSION: DLP/ED conversion coefficients are provided for lower extremities and allow estimation of ED for commonly used clinical musculoskeletal CT and CT angiographic protocols.


Assuntos
Extremidade Inferior/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X , Adulto , Feminino , Humanos , Masculino , Método de Monte Carlo , Radiometria , Software
8.
Phys Med Biol ; 58(12): 4205-23, 2013 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-23715466

RESUMO

The purpose of this study was to investigate the effect of shaped filters specifically designed for dedicated breast computed tomography (CT) scanners on dose and image quality. Optimization of filter shape and material in fan direction was performed using two different design methods, one aiming at homogeneous noise distributions in the CT images and the other aiming at a uniform dose distribution in the breast. The optimal filter thickness as a function of fan angle was determined iteratively to fulfil the above mentioned criteria for each breast diameter. Different filter materials (aluminium, copper, carbon, polytetrafluoroethylene) and breast phantoms with diameters between 80-180 mm were investigated. Noise uniformity in the reconstructed images, obtained from CT simulations based on ray-tracing methods, and dose in the breast, calculated with a Monte Carlo software tool, were used as figure of merit. Furthermore, CT-value homogeneity, the distribution of noise in cone direction, spatial resolution from centre to periphery and the contrast-to-noise ratio weighted by dose (CNRD) were evaluated. In addition, the decrease of scatter due to shaped filters was investigated. Since only few or one filter are practical in clinical CT systems, the effects of one shaped filter for different breast diameters were also investigated. In this case the filter, designed for the largest breast diameter, was simulated at variable source-to-filter distances depending on breast diameter. With the filter design method aiming at uniform noise distribution best results were obtained for aluminium as the filter material. Noise uniformity improved from 20} down to 5} and dose was reduced by about 30-40} for all breast diameters. No decrease of noise uniformity in cone direction, CT-value homogeneity, spatial resolution and the CNRD was detected with the shaped filter. However, a small improvement of CNRD was observed. Furthermore, a scatter reduction of about 20-30} and a more homogeneous scatter distribution were reached which led to reduced cupping artefacts. The simulations with one shaped filter at variable source-to-filter distance resulted in nearly homogeneous noise distributions and comparable dose reduction for all breast diameters. In conclusion, by means of shaped filters designed for breast CT, significant dose reduction can be achieved at unimpaired image quality. One shaped filter designed for the largest breast diameter used with variable source-to-filter distance appears to be the best solution for breast CT.


Assuntos
Mamografia/instrumentação , Doses de Radiação , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Controle de Qualidade , Espalhamento de Radiação , Razão Sinal-Ruído
9.
Med Phys ; 39(6): 3229-39, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22755706

RESUMO

PURPOSE: To optimize micro-CT protocols with respect to x-ray spectra and thereby reduce radiation dose at unimpaired image quality. METHODS: Simulations were performed to assess image contrast, noise, and radiation dose for different imaging tasks. The figure of merit used to determine the optimal spectrum was the dose-weighted contrast-to-noise ratio (CNRD). Both optimal photon energy and tube voltage were considered. Three different types of filtration were investigated for polychromatic x-ray spectra: 0.5 mm Al, 3.0 mm Al, and 0.2 mm Cu. Phantoms consisted of water cylinders of 20, 32, and 50 mm in diameter with a central insert of 9 mm which was filled with different contrast materials: an iodine-based contrast medium (CM) to mimic contrast-enhanced (CE) imaging, hydroxyapatite to mimic bone structures, and water with reduced density to mimic soft tissue contrast. Validation measurements were conducted on a commercially available micro-CT scanner using phantoms consisting of water-equivalent plastics. Measurements on a mouse cadaver were performed to assess potential artifacts like beam hardening and to further validate simulation results. RESULTS: The optimal photon energy for CE imaging was found at 34 keV. For bone imaging, optimal energies were 17, 20, and 23 keV for the 20, 32, and 50 mm phantom, respectively. For density differences, optimal energies varied between 18 and 50 keV for the 20 and 50 mm phantom, respectively. For the 32 mm phantom and density differences, CNRD was found to be constant within 2.5% for the energy range of 21-60 keV. For polychromatic spectra and CMs, optimal settings were 50 kV with 0.2 mm Cu filtration, allowing for a dose reduction of 58% compared to the optimal setting for 0.5 mm Al filtration. For bone imaging, optimal tube voltages were below 35 kV. For soft tissue imaging, optimal tube settings strongly depended on phantom size. For 20 mm, low voltages were preferred. For 32 mm, CNRD was found to be almost independent of tube voltage. For 50 mm, voltages larger than 50 kV were preferred. For all three phantom sizes stronger filtration led to notable dose reduction for soft tissue imaging. Validation measurements were found to match simulations well, with deviations being less than 10%. Mouse measurements confirmed simulation results. CONCLUSIONS: Optimal photon energies and tube settings strongly depend on both phantom size and imaging task at hand. For in vivo CE imaging and density differences, strong filtration and voltages of 50-65 kV showed good overall results. For soft tissue imaging of animals the size of a rat or larger, voltages higher than 65 kV allow to greatly reduce scan times while maintaining dose efficiency. For imaging of bone structures, usage of only minimum filtration and low tube voltages of 40 kV and below allow exploiting the high contrast of bone at very low energies. Therefore, a combination of two filtrations could prove beneficial for micro-CT: a soft filtration allowing for bone imaging at low voltages, and a variable stronger filtration (e.g., 0.2 mm Cu) for soft tissue and contrast-enhanced imaging.


Assuntos
Microtomografia por Raio-X/métodos , Animais , Cor , Processamento de Imagem Assistida por Computador , Camundongos , Método de Monte Carlo , Imagens de Fantasmas , Fótons , Doses de Radiação , Análise Espectral
10.
Invest Radiol ; 47(8): 462-7, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22717880

RESUMO

OBJECTIVES: Dynamic contrast-enhanced imaging allows assessing functional information in addition to morphology using various modalities. Several applications have been established in clinical practice; however, there is no standard with respect to injection protocols or postprocessing algorithms. The purpose of this study was to develop a phantom for generating reproducible contrast-enhancement curves and providing a standard for comparison of different protocols and modalities in dynamic imaging. MATERIALS AND METHODS: Our experimental setup consists of a peristaltic pump to generate a water flow through the phantom and a contrast injection pump. The phantom holds a sequence of layers allowing for assessment of perfusion, signal-to-noise ratio, and spatiotemporal resolution; the latter is the spatial resolution of structures with temporally changing contrast. Reproducibility was evaluated by the functional parameters time to peak, mean transit time, and peak enhancement by 24 scans over 4 weeks on a clinical computed tomography scanner. In addition, the area under the curve was evaluated for different injection durations at constant injection volume. Spatiotemporal resolution was assessed by spatial profiles on perfused bore patterns and compared for standard reconstructions, smooth reconstructions, and highly constrained backprojection for local reconstruction (HYPR LR). RESULTS: The phantom showed good reproducibility in repeated measurements, with maximal deviations of 4% for time to peak, 9% for mean transit time, and 8% for peak enhancement. Area under the curve was constant within 3.5% for different injection protocols. For the static case, HYPR LR maintained spatial resolution. For dynamic objects, however, HYPR LR reduced spatial resolution dependent on temporal dynamics by up to 19% for highest dynamics, which was still superior to smooth reconstructions (27%). CONCLUSIONS: The proposed phantom showed good reproducibility and therefore allows for comparing injection protocols or modalities in dynamic imaging. Assessment of spatiotemporal resolution under measurement conditions provides means for assessing postprocessing methods and reconstruction techniques in dynamic imaging.


Assuntos
Meios de Contraste , Bombas de Infusão , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/instrumentação , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Polimetil Metacrilato , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Fatores de Tempo
11.
Med Phys ; 39(4): 2249-60, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22482646

RESUMO

PURPOSE: Modern computed tomography (CT) systems are supporting increasingly fast rotation speeds, which are a prerequisite for fast dynamic acquisition, e.g. in perfusion imaging, and for new modalities such as dedicated breast CT, where breathhold scanning is indicated. However, not all detector technologies are supporting the high frame rates that are necessary to retain high resolution for objects far away from the isocenter. Even on systems that would support a sufficiently high frame rate, the necessary bandwidth of the data transfer from the rotating gantry stills remains challenging. The authors evaluated a pixel shifting technique termed time-delayed summation (TDS) as a method of increasing resolution on fast rotating CT systems without the need to increase the frame rate. METHODS: In TDS mode, detector pixel values are shifted along rows during image acquisition to compensate for detector motion. In order to fully exploit TDS, focal spot position control (FSC) was used in combination with TDS. FSC applies a counter movement to the x-ray focal spot during image acquisition such that it is kept fixed in space. As a proof of concept, measurements were performed on a prototype photon counting detector capable of TDS. The detector was mounted on a movable table and a gold wire phantom was imaged with different TDS settings and detector velocities. Additionally, simulations of a broad range of TDS and FSC settings on two different modalities, a clinical CT scanner and a breast CT scanner, and two different detector geometries, flat and cylindrical, were performed to assess the gain in resolution and contrast in cylindrical water phantoms containing a small wire at distances from the phantom center varied from 5% to 90% of the phantom radius. As figures of merit, the modulation transfer function (MTF) at 10% and the maximum contrast were used and compared against the respective values when using step-and-shoot acquisition, which means stopping the rotation when a projection image is acquired. RESULTS: Measurements showed that detector movement and the resulting blurring of the wire projections were compensated to the expected degree when using the appropriate number of TDS shifts per frame (TDS factor). Using simulations it was found that when using the optimal TDS factor, over 90% of the resolution achieved in step-and-shot mode was reached for all investigated wire positions. TDS showed better performance on a cylindrical detector that on the same system with a flat detector. TDS factors that were deviating from the optimum by more than 1 shift led to a performance below that of standard continuous acquisition. CONCLUSIONS: The findings of this study encourage the combined usage of TDS and FSC in systems that require fast rotation. The integration of TDS in state-of-the-art x-ray detectors is feasible.


Assuntos
Algoritmos , Imageamento Tridimensional/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Rotação , Sensibilidade e Especificidade , Fatores de Tempo , Tomografia Computadorizada por Raios X/instrumentação
12.
Phys Med Biol ; 57(10): N173-82, 2012 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-22517124

RESUMO

One of the biggest challenges in dynamic contrast-enhanced CT is the optimal synchronization of scan start and duration with contrast medium administration in order to optimize image contrast and to reduce the amount of contrast medium. We present a new optically based approach, which was developed to investigate and optimize bolus timing and shape. The time-concentration curve of an intravenously injected test bolus of a dye is measured in peripheral vessels with an optical sensor prior to the diagnostic CT scan. The curves can be used to assess bolus shapes as a function of injection protocols and to determine contrast medium arrival times. Preliminary results for phantom and animal experiments showed the expected linear behavior between dye concentration and absorption. The kinetics of the dye was compared to iodinated contrast medium and was found to be in good agreement. The contrast enhancement curves were reliably detected in three mice with individual bolus shapes and delay times of 2.1, 3.5 and 6.1 s, respectively. The optical sensor appears to be a promising approach to optimize injection protocols and contrast enhancement timing and is applicable to all modalities without implying any additional radiation dose. Clinical tests are still necessary.


Assuntos
Meios de Contraste , Fenômenos Ópticos , Tomografia Computadorizada por Raios X/métodos , Animais , Feminino , Humanos , Camundongos , Imagens de Fantasmas , Fatores de Tempo , Tomografia Computadorizada por Raios X/instrumentação
13.
Med Phys ; 39(2): 658-70, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22320775

RESUMO

PURPOSE: At present, no established methods exist for dosimetry in micro computed tomography (micro-CT). The purpose of this study was therefore to investigate practical concepts for both dosimetric scanner quality assurance and tissue dose assessment for micro-CT. METHODS: The computed tomography dose index (CTDI) was adapted to micro-CT and measurements of the CTDI both free in air and in the center of cylindrical polymethyl methacrylate (PMMA) phantoms of 20 and 32 mm diameter were performed in a 6 month interval with a 100 mm pencil ionization chamber calibrated for low tube voltages. For tissue dose assessment, z-profile measurements using thermoluminescence dosimeters (TLDs) were performed and both profile and CTDI measurements were compared to Monte Carlo (MC) dose calculations to validate an existing MC tool for use in micro-CT. The consistency of MC calculations and TLD measurements was further investigated in two mice cadavers. RESULTS: CTDI was found to be a reproducible quantity for constancy tests on the micro-CT system under study, showing a linear dependence on tube voltage and being by definition proportional to mAs setting and z-collimation. The CTDI measured free in air showed larger systematic deviations after the 6 month interval compared to the CTDI measured in PMMA phantoms. MC calculations were found to match CTDI measurements within 3% when using x-ray spectra measured at our micro-CT installation and better than 10% when using x-ray spectra calculated from semi-empirical models. Visual inspection revealed good agreement for all z-profiles. The consistency of MC calculations and TLD measurements in mice was found to be better than 10% with a mean deviation of 4.5%. CONCLUSIONS: Our results show the CTDI implemented for micro-CT to be a promising candidate for dosimetric quality assurance measurements as it linearly reflects changes in tube voltage, mAs setting, and collimation used during the scan, encouraging further studies on a variety of systems. For tissue dose assessment, MC calculations offer an accurate and fast alternative to TLD measurements allowing for dose calculations specific to any geometry and scan protocol.


Assuntos
Modelos Biológicos , Garantia da Qualidade dos Cuidados de Saúde/métodos , Doses de Radiação , Radiometria/métodos , Radiometria/normas , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas , Animais , Simulação por Computador , Alemanha , Camundongos , Garantia da Qualidade dos Cuidados de Saúde/normas
14.
Eur Radiol ; 22(4): 900-7, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22071777

RESUMO

OBJECTIVE: To evaluate the potential of in vivo dynamic contrast-enhanced micro-computed tomography (DCE micro-CT) for the assessment of antiangiogenic drug therapy response of mice with mammary carcinoma. METHODS: 20 female mice with implanted MCF7 tumours were split into control group and therapy group treated with a known effective antiangiogenic drug. All mice underwent DCE micro-CT for the 3D analysis of functional parameters (relative blood volume [rBV], vascular permeability [K], area under the time-enhancement curve [AUC]) and morphology. All parameters were determined for total, peripheral and central tumour volumes of interest (VOIs). Immunohistochemistry was performed to characterise tumour vascularisation. 3D dose distributions were determined. RESULTS: The mean AUCs were significantly lower in therapy with P values of 0.012, 0.007 and 0.023 for total, peripheral and central tumour VOIs. K and rBV showed significant differences for the peripheral (P(per)(K) = 0.032, P(per) (rBV) = 0.029), but not for the total and central tumour VOIs (P(total)(K) = 0.108, P(central)(K) = 0.246, P(total) (rBV) = 0.093, P(central) (rBV) = 0.136). Mean tumour volume was significantly smaller in therapy (P (in vivo) = 0.001, P (ex vivo) = 0.005). Histology revealed greater vascularisation in the controls and central tumour necrosis. Doses ranged from 150 to 300 mGy. CONCLUSIONS: This study indicates the great potential of DCE micro-CT for early in vivo assessment of antiangiogenic drug therapy response. KEY POINTS: Dynamic contrast enhanced micro-CT (computed tomography) is a new experimental laboratory technique. DCE micro-CT allows early in vivo assessment of antiangiogenic drug therapy response. Pharmaceutical drugs can be tested before translation to clinical practice. Both morphological and functional parameters can be obtained using DCE micro-CT. Antiangiogenic effects can be visualised with DCE micro-CT.


Assuntos
Inibidores da Angiogênese/administração & dosagem , Imageamento Tridimensional/veterinária , Iohexol/análogos & derivados , Neoplasias Mamárias Experimentais/diagnóstico por imagem , Neoplasias Mamárias Experimentais/tratamento farmacológico , Sirolimo/análogos & derivados , Tomografia Computadorizada por Raios X/veterinária , Animais , Linhagem Celular Tumoral , Meios de Contraste , Everolimo , Feminino , Camundongos , Camundongos Nus , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sirolimo/administração & dosagem , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
15.
Med Phys ; 38(12): 6469-82, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22149830

RESUMO

PURPOSE: Currently, only iodine- and barium-based contrast media (CM) are used in clinical contrast-enhanced computed tomography (CE-CT). High-Z metals would produce a higher contrast at equal mass density for the x-ray spectra used in clinical CT. Using such materials might allow for significant dose reductions in CE-CT. The purpose of this study was to quantify the potential for dose reduction when using CM based on heavy metals. METHODS: The contrast-to-noise ratio weighted by dose (CNRD) was determined as a function of scan protocol by means of measurements and simulations on a clinical CT scanner. For simulations, water cylinders with diameters 160, 320, 480, and 640 mm were used to cover a broad range of patient sizes. Measurements were conducted with 160 and 320 mm water-equivalent plastic cylinders. A central bore of 13 mm diameter was present in all phantoms. The tube voltage was varied from 80 to 140 kV for measurements and from 60 to 180 kV for simulations. Additional tin filtration of thicknesses 0.4, 0.8, and 1.2 mm was applied in the simulation to evaluate a range of spectral hardness. The bore was filled with a mixture of water and 10 mg/ml of pure iodine, holmium, gadolinium, ytterbium, osmium, tungsten, gold, and bismuth for the simulations and with aqueous solutions of ytterbium, tungsten, gold, and bismuth salts as well as Iopromid containing 10 mg/ml of the pure materials for the measurements. CNRDs were compared to iodine at phantom size-dependent reference voltages for all high-Z materials and the resulting dose reduction was calculated for equal contrast-to-noise ratio. RESULTS: Dose reduction potentials strongly depended on phantom size, spectral hardness, and tube voltage. Depending on the added filtration, a dose reduction of 19%-60% could be reached at 80 kV with gadolinium for the 160 mm phantom, 52%-69% at 100 kV with holmium for the 320 mm phantom, 62%-78% with 120 kV for hafnium and the 480 mm phantom and 74%-86% with 140 kV for gold and the 640 mm phantom. While gadolinium might be considered at 160 mm diameter, hafnium showed the best overall performance for phantom sizes of 320 mm and above. The measurements conducted on the clinical CT scanner showed very good agreement with simulations with deviations in the order of 5 to 10%. CONCLUSIONS: The results of this study encourage the development and use of CM based on high-Z materials, especially for adipose patients, where high tube voltages are necessary to reach sufficiently short scan times. Hafnium proved to be the best compromise for average-size and for adipose patients. Even higher-Z materials such as gold and bismuth showed a good overall performance in conjunction with high tube voltage, large patients or strong added filtration and may be recommended for scans under these conditions.


Assuntos
Aumento da Imagem/métodos , Metais , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste/química , Estudos de Viabilidade , Metais/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade