Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Artigo em Coreano | WPRIM (Pacífico Ocidental) | ID: wpr-901129

RESUMO

Purpose@#To compare differences between the original criteria for diagnosis of ocular sarcoidosis (OS) (first International Workshop for OS [IWOS] 2009) and the revised criteria (sixth IWOS 2017), and their clinical usefulness when assessing OS in Korean patients. @*Methods@#We analyzed patients with suspected OS who visited our tertiary referral ophthalmological and pulmonary clinic from 2007 to 2018. We diagnosed patients using both sets of criteria. Blood test and biopsy data (collected by physicians) and slit-lamp, fundus, and fluorescein angiography data (collected by ophthalmologists) were reviewed. @*Results@#Thirty-four patients were diagnosed using both criteria. Of 32 patients who underwent biopsies, 31 had OS (96.87%). Using either set of criteria, 31 patients were diagnosed with definite OS and two with presumed OS. One patient diagnosed with possible OS using the previous criteria was diagnosed with presumed OS using the revised criteria. The new criteria add the lysozyme level, the CD4/CD8 ratio, and positron emission tomography imaging data to the old criteria and add the descriptors “presumed OS” and “probable OS”. There is no need to use the revised criteria in Korea; the biopsy and imaging data are adequately diagnostic. @*Conclusions@#IWOS revised the OS diagnostic criteria by adding new parameters. However, this was unnecessary for Korea, where the biopsy and imaging data are adequately diagnostic.

2.
Artigo em Coreano | WPRIM (Pacífico Ocidental) | ID: wpr-893425

RESUMO

Purpose@#To compare differences between the original criteria for diagnosis of ocular sarcoidosis (OS) (first International Workshop for OS [IWOS] 2009) and the revised criteria (sixth IWOS 2017), and their clinical usefulness when assessing OS in Korean patients. @*Methods@#We analyzed patients with suspected OS who visited our tertiary referral ophthalmological and pulmonary clinic from 2007 to 2018. We diagnosed patients using both sets of criteria. Blood test and biopsy data (collected by physicians) and slit-lamp, fundus, and fluorescein angiography data (collected by ophthalmologists) were reviewed. @*Results@#Thirty-four patients were diagnosed using both criteria. Of 32 patients who underwent biopsies, 31 had OS (96.87%). Using either set of criteria, 31 patients were diagnosed with definite OS and two with presumed OS. One patient diagnosed with possible OS using the previous criteria was diagnosed with presumed OS using the revised criteria. The new criteria add the lysozyme level, the CD4/CD8 ratio, and positron emission tomography imaging data to the old criteria and add the descriptors “presumed OS” and “probable OS”. There is no need to use the revised criteria in Korea; the biopsy and imaging data are adequately diagnostic. @*Conclusions@#IWOS revised the OS diagnostic criteria by adding new parameters. However, this was unnecessary for Korea, where the biopsy and imaging data are adequately diagnostic.

3.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-20167874

RESUMO

The rapid spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is due to the high rates of transmission by individuals who are asymptomatic at the time of transmission1, 2. Frequent, widespread testing of the asymptomatic population for SARS-CoV-2 is essential to suppress viral transmission. Despite increases in testing capacity, multiple challenges remain in deploying traditional reverse transcription and quantitative PCR (RT-qPCR) tests at the scale required for population screening of asymptomatic individuals. We have developed SwabSeq, a high-throughput testing platform for SARS-CoV-2 that uses next-generation sequencing as a readout. SwabSeq employs sample-specific molecular barcodes to enable thousands of samples to be combined and simultaneously analyzed for the presence or absence of SARS-CoV-2 in a single run. Importantly, SwabSeq incorporates an in vitro RNA standard that mimics the viral amplicon, but can be distinguished by sequencing. This standard allows for end-point rather than quantitative PCR, improves quantitation, reduces requirements for automation and sample-to-sample normalization, enables purification-free detection, and gives better ability to call true negatives. After setting up SwabSeq in a high-complexity CLIA laboratory, we performed more than 80,000 tests for COVID-19 in less than two months, confirming in a real world setting that SwabSeq inexpensively delivers highly sensitive and specific results at scale, with a turn-around of less than 24 hours. Our clinical laboratory uses SwabSeq to test both nasal and saliva samples without RNA extraction, while maintaining analytical sensitivity comparable to or better than traditional RT-qPCR tests. Moving forward, SwabSeq can rapidly scale up testing to mitigate devastating spread of novel pathogens.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA