Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.083
Filtrar
1.
Prenat Diagn ; 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39138024

RESUMO

OBJECTIVE: To assess the frequency of fetal therapy for fetuses with congenital pulmonary malformations (CPMs) and to investigate their short-term outcomes. METHOD: The study population included 435 singleton fetuses diagnosed with CPMs from a national population-based cohort study in France in 2015-2018. Information was obtained from medical records on CPM volume ratio (CVR), signs of compression, fetal therapy and perinatal outcomes. The characteristics and outcomes of fetuses with and without fetal therapy were compared using a univariate test. RESULTS: Twenty six fetuses (6.0%, 95% CI: 4.1-8.6) received at least one fetal therapy including thoracoamniotic shunts only (n = 3), antenatal steroids only (n = 12), and a combination of several therapies including thoracentesis and amniodrainage, in addition to shunts and steroids (n = 11). Compared with fetuses without fetal therapy, those who did have higher CVR (1.6 ± 0.3 vs. 0.7 ± 0.04, p < 0.001) and more severe signs of compression (73.1% vs. 12.8%, p < 0.001). The proportion of live births after fetal therapy was 84.6% versus 98.5% (p < 0.001) for those without fetal therapy and the hospital mortality rate was 13.6% versus 1.0% (p = 0.004), respectively. CONCLUSION: A small minority of fetuses with CPMs underwent fetal therapy. These patients had a lower survival compared with those who did not receive fetal therapy. TRIAL REGISTRATION: NCT02352207.

2.
Eur Heart J ; 45(27): 2396-2406, 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-39193886

RESUMO

BACKGROUND AND AIMS: It has been reported that patients without standard modifiable cardiovascular (CV) risk factors (SMuRFs-diabetes, dyslipidaemia, hypertension, and smoking) presenting with first myocardial infarction (MI), especially women, have a higher in-hospital mortality than patients with risk factors, and possibly a lower long-term risk provided they survive the post-infarct period. This study aims to explore the long-term outcomes of SMuRF-less patients with stable coronary artery disease (CAD). METHODS: CLARIFY is an observational cohort of 32 703 outpatients with stable CAD enrolled between 2009 and 2010 in 45 countries. The baseline characteristics and clinical outcomes of patients with and without SMuRFs were compared. The primary outcome was a composite of 5-year CV death or non-fatal MI. Secondary outcomes were 5-year all-cause mortality and major adverse cardiovascular events (MACE-CV death, non-fatal MI, or non-fatal stroke). RESULTS: Among 22 132 patients with complete risk factor and outcome information, 977 (4.4%) were SMuRF-less. Age, sex, and time since CAD diagnosis were similar across groups. SMuRF-less patients had a lower 5-year rate of CV death or non-fatal MI (5.43% [95% CI 4.08-7.19] vs. 7.68% [95% CI 7.30-8.08], P = 0.012), all-cause mortality, and MACE. Similar results were found after adjustments. Clinical event rates increased steadily with the number of SMuRFs. The benefit of SMuRF-less status was particularly pronounced in women. CONCLUSIONS: SMuRF-less patients with stable CAD have a substantial but significantly lower 5-year rate of CV death or non-fatal MI than patients with risk factors. The risk of CV outcomes increases steadily with the number of risk factors.


Assuntos
Fatores de Risco de Doenças Cardíacas , Infarto do Miocárdio , Sistema de Registros , Humanos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/mortalidade , Hipertensão/complicações , Hipertensão/epidemiologia , Fumar/efeitos adversos , Fumar/epidemiologia , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/complicações , Dislipidemias/epidemiologia , Dislipidemias/complicações , Doença Crônica , Fatores de Risco , Diabetes Mellitus/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/prevenção & controle
3.
Plant Cell Environ ; 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39189974

RESUMO

Increases in shrub height, biomass and canopy cover are key whole-plant features of warming-induced vegetation change in tundra. We investigated leaf functional traits underlying photosynthetic capacity of Arctic shrub species, particularly its main limiting processes such as mesophyll conductance. In this nutrient-limited ecosystem, we expect leaf nitrogen concentration to be the main limiting factor for photosynthesis. We measured the net photosynthetic rate at saturated light (Asat) in three Salix species throughout a glacial valley in High-Arctic tundra and used a causal approach to test relationships between leaf stomatal and mesophyll conductances (gsc, gm), carboxylation capacity (Vcmax), nitrogen and phosphorus concentration (Narea, Parea) and leaf mass ratio (LMA). Arctic Salix species showed no difference in Asat compared to a global data set, while being characterized by higher Narea, Parea and LMA. Vcmax, gsc and gm independently increased Asat, with Vcmax as its main limitation. We highlighted a nitrogen-influenced pathway for increasing photosynthesis in the two prostrate mesic habitat species. In contrast, the erect wetland habitat Salix richardsonii mainly increased Asat with increasing gsc. Overall, our study revealed high photosynthetic capacities of Arctic Salix species but contrasting regulatory pathways that may influence shrub ability to respond to environmental changes in High Arctic tundra.

4.
BJOG ; 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39118202

RESUMO

OBJECTIVES: Accurate assessment of gestational age (GA) is important at both individual and population levels. The most accurate way to estimate GA in women who book late in pregnancy is unknown. The aim of this study was to externally validate the accuracy of equations for GA estimation in late pregnancy and to identify the best equation for estimating GA in women who do not receive an ultrasound scan until the second or third trimester. DESIGN: This was a prospective, observational cross-sectional study. SETTING: 57 prenatal care centres, France. PARTICIPANTS: Women with a singleton pregnancy and a previous 11-14-week dating scan that gave the observed GA were recruited over an 8-week period. They underwent a standardised ultrasound examination at one time point during the pregnancy (15-43 weeks), measuring 12 foetal biometric parameters that have previously been identified as useful for GA estimation. MAIN OUTCOME MEASURES: A total of 189 equations that estimate GA based on foetal biometry were examined and compared with GA estimation based on foetal CRL. Comparisons between the observed GA and the estimated GA were made using R2, calibration slope and intercept. RMSE, mean difference and 95% range of error were also calculated. RESULTS: A total of 2741 pregnant women were examined. After exclusions, 2339 participants were included. In the 20 best performing equations, the intercept ranged from -0.22 to 0.30, the calibration slope from 0.96 to 1.03 and the RSME from 0.67 to 0.87. Overall, multiparameter models outperformed single-parameter models. Both the 95% range of error and mean difference increased with gestation. Commonly used models based on measurement of the head circumference alone were not amongst the best performing models and were associated with higher 95% error and mean difference. CONCLUSIONS: We provide strong evidence that GA-specific equations based on multiparameter models should be used to estimate GA in late pregnancy. However, as all methods of GA assessment in late pregnancy are associated with large prediction intervals, efforts to improve access to early antenatal ultrasound must remain a priority. TRIAL REGISTRATION: The proposal for this study and the corresponding methodological review was registered on PROSPERO international register of systematic reviews (registration number: CRD4201913776).

5.
Sensors (Basel) ; 24(14)2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-39065908

RESUMO

BACKGROUND: While low back pain (LBP) is the leading cause of disability worldwide, its clinical objective assessment is currently limited. Part of this syndrome arises from the abnormal sensorimotor control of back muscles, involving increased muscle fatigability (i.e., assessed with the Biering-Sorensen test) and abnormal muscle activation patterns (i.e., the flexion-extension test). Surface electromyography (sEMG) provides objective measures of muscle fatigue development (median frequency drop, MDF) and activation patterns (RMS amplitude change). This study therefore assessed the sensitivity and validity of a novel and flexible sEMG system (NSS) based on PEVA electrodes and potentially embeddable in textiles, as a tool for objective clinical LBP assessment. METHODS: Twelve participants wearing NSS and a commercial laboratory sEMG system (CSS) performed two clinical tests used in LBP assessment (Biering-Sorensen and flexion-extension). Erector spinae muscle activity was recorded at T12-L1 and L4-L5. RESULTS: NSS showed sensitivity to sEMG changes associated with fatigue development and muscle activations during flexion-extension movements (p < 0.05) that were similar to CSS (p > 0.05). Raw signals showed moderate cross-correlations (MDF: 0.60-0.68; RMS: 0.53-0.62). Adding conductive gel to the PEVA electrodes did not influence sEMG signal interpretation (p > 0.05). CONCLUSIONS: This novel sEMG system is promising for assessing electrophysiological indicators of LBP during clinical tests.


Assuntos
Músculos do Dorso , Eletromiografia , Dor Lombar , Dispositivos Eletrônicos Vestíveis , Eletrodos , Eletromiografia/instrumentação , Eletromiografia/métodos , Projetos Piloto , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Músculos do Dorso/fisiopatologia , Manejo da Dor , Fadiga Muscular , Dor Lombar/fisiopatologia
6.
Artigo em Inglês | MEDLINE | ID: mdl-38935466

RESUMO

Walking patterns are modified during load carriage, resulting in an increased activation of lower limb muscles and energy expenditure. Negative effects of load carriage could be minimized by wearing an exoskeleton, but evidence on the effects are conflicting. The objectives of this study were to describe the influence of an adjustable, passive load-bearing exoskeleton on the metabolic cost of walking (MCW) and associated muscle activations, and to explore changes in MCW after a familiarization process. Thirteen participants walked on a treadmill with a 22.75 kg payload at six preselected speeds (from 0.67 to 1.56 m/s) under three walking conditions: 1) without exoskeleton (NoExo); 2) with exoskeleton before familiarization (ExoPre); and 3) with exoskeleton after familiarization (ExoPost). Metabolic data was normalized to walking speed to provide MCW. Multi-muscle surface electromyography (EMG) was time and amplitude normalized to the gait cycle to provide muscle activation patterns. The familiarization occurred over three weeks including exposure to the exoskeleton. Differences in MCW and muscle activations were compared using a nonparametric analysis of longitudinal data. There were statistically significant increases in MCW for all speeds in the ExoPre and ExoPost conditions compared the NoExo. The average muscle activation showed an increase during ExoPre and ExoPost for the three speeds evaluated. Post-hoc analysis showed no significant effect of the familiarization period on metabolic data. In conclusion, a first exposure to the adjustable exoskeleton increased MCW and muscle activations, but the familiarization process did not provide any benefits toward a reduction in MCW or reduction in muscle activations at all speeds evaluated.


Assuntos
Eletromiografia , Exoesqueleto Energizado , Extremidade Inferior , Músculo Esquelético , Consumo de Oxigênio , Caminhada , Suporte de Carga , Humanos , Caminhada/fisiologia , Masculino , Músculo Esquelético/fisiologia , Adulto , Extremidade Inferior/fisiologia , Consumo de Oxigênio/fisiologia , Feminino , Adulto Jovem , Suporte de Carga/fisiologia , Metabolismo Energético/fisiologia , Marcha/fisiologia , Fenômenos Biomecânicos , Voluntários Saudáveis
7.
Ann Intensive Care ; 14(1): 78, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38776032

RESUMO

BACKGROUND: Reverse triggering (RT) was described in 2013 as a form of patient-ventilator asynchrony, where patient's respiratory effort follows mechanical insufflation. Diagnosis requires esophageal pressure (Pes) or diaphragmatic electrical activity (EAdi), but RT can also be diagnosed using standard ventilator waveforms. HYPOTHESIS: We wondered (1) how frequently RT would be present but undetected in the figures from literature, especially before 2013; (2) whether it would be more prevalent in the era of small tidal volumes after 2000. METHODS: We searched PubMed, EMBASE, and the Cochrane Central Register of Controlled Trials, from 1950 to 2017, with key words related to asynchrony to identify papers with figures including ventilator waveforms expected to display RT if present. Experts labelled waveforms. 'Definite' RT was identified when Pes or EAdi were in the tracing, and 'possible' RT when only flow and pressure waveforms were present. Expert assessment was compared to the author's descriptions of waveforms. RESULTS: We found 65 appropriate papers published from 1977 to now, containing 181 ventilator waveforms. 21 cases of 'possible' RT and 25 cases of 'definite' RT were identified by the experts. 18.8% of waveforms prior to 2013 had evidence of RT. Most cases were published after 2000 (1 before vs. 45 after, p = 0.03). 54% of RT cases were attributed to different phenomena. A few cases of identified RT were already described prior to 2013 using different terminology (earliest in 1997). While RT cases attributed to different phenomena decreased after 2013, 60% of 'possible' RT remained missed. CONCLUSION: RT has been present in the literature as early as 1997, but most cases were found after the introduction of low tidal volume ventilation in 2000. Following 2013, the number of undetected cases decreased, but RT are still commonly missed. Reverse Triggering, A Missed Phenomenon in the Literature. Critical Care Canada Forum 2019 Abstracts. Can J Anesth/J Can Anesth 67 (Suppl 1), 1-162 (2020). https://doi-org.myaccess.library.utoronto.ca/ https://doi.org/10.1007/s12630-019-01552-z .

8.
Crit Care ; 28(1): 107, 2024 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-38566126

RESUMO

BACKGROUND: Pre-clinical studies suggest that dyssynchronous diaphragm contractions during mechanical ventilation may cause acute diaphragm dysfunction. We aimed to describe the variability in diaphragm contractile loading conditions during mechanical ventilation and to establish whether dyssynchronous diaphragm contractions are associated with the development of impaired diaphragm dysfunction. METHODS: In patients receiving invasive mechanical ventilation for pneumonia, septic shock, acute respiratory distress syndrome, or acute brain injury, airway flow and pressure and diaphragm electrical activity (Edi) were recorded hourly around the clock for up to 7 days. Dyssynchronous post-inspiratory diaphragm loading was defined based on the duration of neural inspiration after expiratory cycling of the ventilator. Diaphragm function was assessed on a daily basis by neuromuscular coupling (NMC, the ratio of transdiaphragmatic pressure to diaphragm electrical activity). RESULTS: A total of 4508 hourly recordings were collected in 45 patients. Edi was low or absent (≤ 5 µV) in 51% of study hours (median 71 h per patient, interquartile range 39-101 h). Dyssynchronous post-inspiratory loading was present in 13% of study hours (median 7 h per patient, interquartile range 2-22 h). The probability of dyssynchronous post-inspiratory loading was increased with reverse triggering (odds ratio 15, 95% CI 8-35) and premature cycling (odds ratio 8, 95% CI 6-10). The duration and magnitude of dyssynchronous post-inspiratory loading were associated with a progressive decline in diaphragm NMC (p < 0.01 for interaction with time). CONCLUSIONS: Dyssynchronous diaphragm contractions may impair diaphragm function during mechanical ventilation. TRIAL REGISTRATION: MYOTRAUMA, ClinicalTrials.gov NCT03108118. Registered 04 April 2017 (retrospectively registered).


Assuntos
Respiração Artificial , Síndrome do Desconforto Respiratório , Humanos , Diafragma , Respiração Artificial/efeitos adversos , Tórax , Ventiladores Mecânicos
9.
Respir Care ; 69(4): 395-406, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38538026

RESUMO

BACKGROUND: Aerosol barrier enclosure systems have been designed to prevent airborne contamination, but their safety has been questioned. A vacuum tent was designed with active continuous suctioning to minimize risks of aerosol dispersion. We tested its efficacy, risk of rebreathing, and usability on a bench, in healthy volunteers, and in an ergonomic clinical assessment study. METHODS: First, a manikin with airway connected to a breathing simulator was placed inside the vacuum tent to generate active breathing, cough, and CO2 production; high-flow nasal cannula (HFNC) was applied in the manikin's nares. Negative pressure was applied in the vacuum tent's apex port using wall suction. Fluorescent microparticles were aerosolized in the vacuum tent for qualitative assessment. To quantify particles inside and around vacuum tent (aerosol retention), an airtight aerosol chamber with aerosolized latex microparticles was used. The vacuum tent was tested on healthy volunteers breathing with and without HFNC. Last, its usability was assessed in 5 subjects by 5 different anesthesiologists for delivery of full anesthesia, including intubation and extubation. RESULTS: The vacuum tent was adjusted until no leak was visualized using fluorescent particles. The efficacy in retaining microparticles was confirmed quantitatively. CO2 accumulation inside the vacuum tent showed an inverse correlation with the suction flow in all conditions (normal breathing and HFNC 30 or 60 L/min) in bench and healthy volunteers. Particle removal efficacy and safe breathing conditions (CO2, temperature) were reached when suctioning was at least 60 L/min or 20 L/min > HFNC flow. Five subjects were successfully intubated and anesthetized without ergonomic difficulties and with minimal interference with workflow and an excellent overall assessment by the anesthesiologists. CONCLUSIONS: The vacuum tent effectively minimized aerosol dispersion. Its continuous suction system set at a high suction flow was crucial to avoid the spread of aerosol particles and CO2 rebreathing.


Assuntos
Dióxido de Carbono , Aerossóis e Gotículas Respiratórios , Humanos , Vácuo , Respiração , Nebulizadores e Vaporizadores , Aerossóis
10.
Prenat Diagn ; 44(5): 555-561, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38448008

RESUMO

OBJECTIVE: In singleton pregnancies, the use of cell-free DNA (cfDNA) analysis as a screening test for common fetal trisomies has spread worldwide though we still lack sufficient data for its use in triplet pregnancies. The objective of this study is to assess the performance of cfDNA testing in detecting fetal aneuploidies in triplet pregnancies as a first-tier test. METHOD: We performed a retrospective cohort study including data from pregnant women with a triplet pregnancy who underwent cfDNA testing between May 1, 2017, and January 15, 2020. cfDNA was obtained by massive parallel sequencing (VeriSeq NIPT solution; Illumina®). The objectives of the study were to assess the diagnostic performance of cfDNA testing for trisomy 21 (T21) (primary outcome), trisomy 18 (T18) and 13 (secondary outcomes). RESULTS: During the study period, cfDNA testing was performed in 255 women with triplet pregnancy, of which 165 (64.7%) had a neonatal outcome available. Three tests were positive for T21, one of which was confirmed by an antenatal karyotype, and the other was confirmed at birth. The third case did not undergo an invasive procedure and was not confirmed at birth (false positive). In one case, cfDNA testing was positive for T18 and was confirmed by an antenatal karyotype. There were no cases of trisomy 13 in the cohort. The no-call rate was 2.4% at first sampling. Fifty-eight (22.7%) women had embryo reduction, which in 40 (69%) of whom was performed after the cfDNA test result. CONCLUSION: cfDNA testing could be offered as primary screening for main fetal aneuploidies in triplet pregnancies after provision of appropriate patient information.


Assuntos
Ácidos Nucleicos Livres , Gravidez de Trigêmeos , Humanos , Feminino , Gravidez , Estudos Retrospectivos , Ácidos Nucleicos Livres/sangue , Ácidos Nucleicos Livres/análise , Adulto , Síndrome da Trissomía do Cromossomo 18/diagnóstico , Síndrome da Trissomía do Cromossomo 18/genética , Síndrome da Trissomía do Cromossomo 18/sangue , Trissomia/diagnóstico , Trissomia/genética , Teste Pré-Natal não Invasivo/métodos , Teste Pré-Natal não Invasivo/estatística & dados numéricos , Teste Pré-Natal não Invasivo/normas , Síndrome da Trissomia do Cromossomo 13/diagnóstico , Síndrome da Trissomia do Cromossomo 13/sangue , Síndrome da Trissomia do Cromossomo 13/genética , Estudos de Coortes , Síndrome de Down/diagnóstico , Síndrome de Down/genética , Testes para Triagem do Soro Materno/métodos , Testes para Triagem do Soro Materno/estatística & dados numéricos , Diagnóstico Pré-Natal/métodos , Diagnóstico Pré-Natal/normas
11.
World Neurosurg ; 185: e1268-e1279, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38514030

RESUMO

OBJECTIVES: Using a laboratory-based optical setup, we show that 5-aminolevulinic acid (5ALA) fluorescence is better detected using the endoscope than the microscope. Furthermore, we present our case series of fully endoscopic 5ALA-guided resection of intraparenchymal tumors. METHODS: A Zeiss Pentero microscope was compared with the Karl Storz Hopkins endoscope. The spectra and intensity of each blue light source were measured. Quantitative fluorescence detection thresholds were measured using a spectrometer. Subjective fluorescence detection thresholds were measured by 6 blinded neuro-oncology surgeons. Clinical data were prospectively collected for all consecutive cases of fully endoscopic 5ALA-guided resection of intraparenchymal tumors between 2012 and 2023. RESULTS: The intensity of blue light on the sample was greater for the endoscope than the microscope at working distances less than 20 mm. The quantitative fluorescence detection thresholds were lower for the endoscope than the microscope at both 30-/10-mm working distances. Fluorescence detection threshold was 0.65%-0.80% relative 4-dicyanomethylene-2-methyl-6-p-dimethylaminostyryl-4H-pyranthe concentration (3.20 × 10-7 to 3.94 × 10-7mol/dm-3) for the microscope, 0.40%-0.55% relative concentrations (1.97 × 10-7 to 2.71 × 10-7mol/dm-3) for the endoscope at 30 mm, and 0.15%-0.30% relative concentrations (7.40 × 10-8 to 1.48 × 10-7mol/dm-3) for the endoscope at 10 mm. In total, 49 5ALA endoscope-assisted brain tumor resections were carried out on 45 patients (mean age = 41 years, male = 28). Greater than 95% resection was achieved in 80% of cases and gross total resection in 42%. Gross total resection was achieved in 100% of tumors in noneloquent locations. There was 1 new neurologic deficit. CONCLUSIONS: The endoscope provides enhanced visualization/detection of 5ALA-induced fluorescence compared with the microscope. 5ALA endoscopic-assisted resection of intraparenchymal tumors is safe and feasible.


Assuntos
Ácido Aminolevulínico , Neoplasias Encefálicas , Neuroendoscopia , Humanos , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/diagnóstico por imagem , Feminino , Masculino , Pessoa de Meia-Idade , Neuroendoscopia/métodos , Neuroendoscopia/instrumentação , Idoso , Adulto , Fármacos Fotossensibilizantes , Fluorescência , Cirurgia Assistida por Computador/métodos , Microscopia/métodos , Microscopia/instrumentação , Procedimentos Neurocirúrgicos/métodos
13.
Am J Obstet Gynecol ; 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38367758

RESUMO

BACKGROUND: In early 2023, when Omicron was the variant of concern, we showed that vaccinating pregnant women decreased the risk for severe COVID-19-related complications and maternal morbidity and mortality. OBJECTIVE: This study aimed to analyze the impact of COVID-19 during pregnancy on newborns and the effects of maternal COVID-19 vaccination on neonatal outcomes when Omicron was the variant of concern. STUDY DESIGN: INTERCOVID-2022 was a large, prospective, observational study, conducted in 40 hospitals across 18 countries, from November 27, 2021 (the day after the World Health Organization declared Omicron the variant of concern) to June 30, 2022, to assess the effect of COVID-19 in pregnancy on maternal and neonatal outcomes and to assess vaccine effectiveness. Women diagnosed with laboratory-confirmed COVID-19 during pregnancy were compared with 2 nondiagnosed, unmatched women recruited concomitantly and consecutively during pregnancy or at delivery. Mother-newborn dyads were followed until hospital discharge. The primary outcomes were a neonatal positive test for COVID-19, severe neonatal morbidity index, severe perinatal morbidity and mortality index, preterm birth, neonatal death, referral to neonatal intensive care unit, and diseases during the neonatal period. Vaccine effectiveness was estimated with adjustment for maternal risk profile. RESULTS: We enrolled 4707 neonates born to 1577 (33.5%) mothers diagnosed with COVID-19 and 3130 (66.5%) nondiagnosed mothers. Among the diagnosed mothers, 642 (40.7%) were not vaccinated, 147 (9.3%) were partially vaccinated, 551 (34.9%) were completely vaccinated, and 237 (15.0%) also had a booster vaccine. Neonates of booster-vaccinated mothers had less than half (relative risk, 0.46; 95% confidence interval, 0.23-0.91) the risk of being diagnosed with COVID-19 when compared with those of unvaccinated mothers; they also had the lowest rates of preterm birth, medically indicated preterm birth, respiratory distress syndrome, and number of days in the neonatal intensive care unit. Newborns of unvaccinated mothers had double the risk for neonatal death (relative risk, 2.06; 95% confidence interval, 1.06-4.00) when compared with those of nondiagnosed mothers. Vaccination was not associated with any congenital malformations. Although all vaccines provided protection against neonatal test positivity, newborns of booster-vaccinated mothers had the highest vaccine effectiveness (64%; 95% confidence interval, 10%-86%). Vaccine effectiveness was not as high for messenger RNA vaccines only. Vaccine effectiveness against moderate or severe neonatal outcomes was much lower, namely 13% in the booster-vaccinated group (all vaccines) and 25% and 28% in the completely and booster-vaccinated groups, respectively (messenger RNA vaccines only). Vaccines were fairly effective in protecting neonates when given to pregnant women ≤100 days (14 weeks) before birth; thereafter, the risk increased and was much higher after 200 days (29 weeks). Finally, none of the neonatal practices studied, including skin-to-skin contact and direct breastfeeding, increased the risk for infecting newborns. CONCLUSION: When Omicron was the variant of concern, newborns of unvaccinated mothers had an increased risk for neonatal death. Neonates of vaccinated mothers had a decreased risk for preterm birth and adverse neonatal outcomes. Because the protective effect of COVID-19 vaccination decreases with time, to ensure that newborns are maximally protected against COVID-19, mothers should receive a vaccine or booster dose no more than 14 weeks before the expected date of delivery.

14.
Intensive Care Med Exp ; 12(1): 20, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38416269

RESUMO

BACKGROUND: Lung- and diaphragm-protective (LDP) ventilation may prevent diaphragm atrophy and patient self-inflicted lung injury in acute respiratory failure, but feasibility is uncertain. The objectives of this study were to estimate the proportion of patients achieving LDP targets in different modes of ventilation, and to identify predictors of need for extracorporeal carbon dioxide removal (ECCO2R) to achieve LDP targets. METHODS: An in silico clinical trial was conducted using a previously published mathematical model of patient-ventilator interaction in a simulated patient population (n = 5000) with clinically relevant physiological characteristics. Ventilation and sedation were titrated according to a pre-defined algorithm in pressure support ventilation (PSV) and proportional assist ventilation (PAV+) modes, with or without adjunctive ECCO2R, and using ECCO2R alone (without ventilation or sedation). Random forest modelling was employed to identify patient-level factors associated with achieving targets. RESULTS: After titration, the proportion of patients achieving targets was lower in PAV+ vs. PSV (37% vs. 43%, odds ratio 0.78, 95% CI 0.73-0.85). Adjunctive ECCO2R substantially increased the probability of achieving targets in both PSV and PAV+ (85% vs. 84%). ECCO2R alone without ventilation or sedation achieved LDP targets in 9%. The main determinants of success without ECCO2R were lung compliance, ventilatory ratio, and strong ion difference. In silico trial results corresponded closely with the results obtained in a clinical trial of the LDP titration algorithm (n = 30). CONCLUSIONS: In this in silico trial, many patients required ECCO2R in combination with mechanical ventilation and sedation to achieve LDP targets. ECCO2R increased the probability of achieving LDP targets in patients with intermediate degrees of derangement in elastance and ventilatory ratio.

15.
Am J Respir Crit Care Med ; 209(12): 1441-1452, 2024 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-38354065

RESUMO

Rationale: It is unknown whether preventing overdistention or collapse is more important when titrating positive end-expiratory pressure (PEEP) in acute respiratory distress syndrome (ARDS). Objectives: To compare PEEP targeting minimal overdistention or minimal collapse or using a compromise between collapse and overdistention in a randomized trial and to assess the impact on respiratory mechanics, gas exchange, inflammation, and hemodynamics. Methods: In a porcine model of ARDS, lung collapse and overdistention were estimated using electrical impedance tomography during a decremental PEEP titration. Pigs were randomized to three groups and ventilated for 12 hours: PEEP set at ⩽3% of overdistention (low overdistention), ⩽3% of collapse (low collapse), and the crossing point of collapse and overdistention. Measurements and Main Results: Thirty-six pigs (12 per group) were included. Median (interquartile range) values of PEEP were 7 (6-8), 11 (10-11), and 15 (12-16) cm H2O in the three groups (P < 0.001). With low overdistension, 6 (50%) pigs died, whereas survival was 100% in both other groups. Cause of death was hemodynamic in nature, with high transpulmonary vascular gradient and high epinephrine requirements. Compared with the other groups, pigs surviving with low overdistension had worse respiratory mechanics and gas exchange during the entire protocol. Minimal differences existed between crossing-point and low-collapse animals in physiological parameters, but postmortem alveolar density was more homogeneous in the crossing-point group. Inflammatory markers were not significantly different. Conclusions: PEEP to minimize overdistention resulted in high mortality in an animal model of ARDS. Minimizing collapse or choosing a compromise between collapse and overdistention may result in less lung injury, with potential benefits of the compromise approach.


Assuntos
Modelos Animais de Doenças , Respiração com Pressão Positiva , Síndrome do Desconforto Respiratório , Animais , Suínos , Respiração com Pressão Positiva/métodos , Síndrome do Desconforto Respiratório/terapia , Síndrome do Desconforto Respiratório/fisiopatologia , Atelectasia Pulmonar/terapia , Atelectasia Pulmonar/fisiopatologia , Distribuição Aleatória , Mecânica Respiratória/fisiologia , Hemodinâmica/fisiologia , Feminino , Troca Gasosa Pulmonar/fisiologia
19.
Ann Bot ; 133(2): 321-336, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38066666

RESUMO

BACKGROUND AND AIMS: Plant vascular diseases significantly impact crop yield worldwide. Esca is a vascular disease of grapevine found globally in vineyards which causes a loss of hydraulic conductance due to the occlusion of xylem vessels by tyloses. However, the integrated response of plant radial growth and physiology in maintaining xylem integrity in grapevine expressing esca symptoms remains poorly understood. METHODS: We investigated the interplay between variation in stem diameter, xylem anatomy, plant physiological response and hydraulic traits in two widespread esca-susceptible cultivars, 'Sauvignon blanc' and 'Cabernet Sauvignon'. We used an original experimental design using naturally infected mature vines which were uprooted and transplanted into pots allowing for their study in a mini-lysimeter glasshouse phenotyping platform. KEY RESULTS: Esca significantly altered the timing and sequence of stem growth periods in both cultivars, particularly the shrinkage phase following radial expansion. Symptomatic plants had a significantly higher density of occluded vessels and lower leaf and whole-plant gas exchange. Esca-symptomatic vines showed compensation mechanisms, producing numerous small functional xylem vessels later in development suggesting a maintenance of stem vascular cambium activity. Stabilization or late recovery of whole-plant stomatal conductance coincided with new healthy shoots at the top of the plant after esca symptoms plateaued. CONCLUSIONS: Modified cropping practices, such as avoiding late-season topping, may enhance resilience in esca-symptomatic plants. These results highlight that integrating dendrometers, xylem anatomy and gas exchange provides insights into vascular pathogenesis and its effects on plant physiology.


Assuntos
Resiliência Psicológica , Doenças Vasculares , Xilema/fisiologia , Folhas de Planta/fisiologia , Aclimatação
20.
Curr Opin Crit Care ; 30(1): 20-27, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38085857

RESUMO

PURPOSE OF REVIEW: Determining the optimal positive end-expiratory pressure (PEEP) setting remains a central yet debated issue in the management of acute respiratory distress syndrome (ARDS).The 'best compliance' strategy set the PEEP to coincide with the peak respiratory system compliance (or 2 cmH 2 O higher) during a decremental PEEP trial, but evidence is conflicting. RECENT FINDINGS: The physiological rationale that best compliance is always representative of functional residual capacity and recruitment has raised serious concerns about its efficacy and safety, due to its association with increased 28-day all-cause mortality in a randomized clinical trial in ARDS patients.Moreover, compliance measurement was shown to underestimate the effects of overdistension, and neglect intra-tidal recruitment, airway closure, and the interaction between lung and chest wall mechanics, especially in obese patients. In response to these concerns, alternative approaches such as recruitment-to-inflation ratio, the nitrogen wash-in/wash-out technique, and electrical impedance tomography (EIT) are gaining attention to assess recruitment and overdistention more reliably and precisely. SUMMARY: The traditional 'best compliance' strategy for determining optimal PEEP settings in ARDS carries risks and overlooks some key physiological aspects. The advent of new technologies and methods presents more reliable strategies to assess recruitment and overdistention, facilitating personalized approaches to PEEP optimization.


Assuntos
Respiração com Pressão Positiva , Síndrome do Desconforto Respiratório , Humanos , Respiração com Pressão Positiva/métodos , Pulmão , Síndrome do Desconforto Respiratório/terapia , Volume de Ventilação Pulmonar , Tomografia Computadorizada por Raios X , Ensaios Clínicos Controlados Aleatórios como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA