Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 15(12): e0243214, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33306678

RESUMO

Wearable sleep technology allows for a less intruding sleep assessment than PSG, especially in long-term sleep monitoring. Though such devices are less accurate than PSG, sleep trackers may still provide valuable information. This study aimed to validate a commercial sleep tracker, Garmin Vivosmart 4 (GV4), against polysomnography (PSG) and to evaluate intra-device reliability (GV4 vs. GV4). Eighteen able-bodied adults (13 females, M = 56.1 ± 12.0 years) with no self-reported sleep disorders were simultaneously sleep monitored by GV4 and PSG for one night while intra-device reliability was monitored in one participant for 23 consecutive nights. Intra-device agreement was considered sufficient (observed agreement = 0.85 ± 0.13, Cohen's kappa = 0.68 ± 0.24). GV4 detected sleep with high accuracy (0.90) and sensitivity (0.98) but low specificity (0.28). Cohen's kappa was calculated for sleep/wake detection (0.33) and sleep stage detection (0.20). GV4 significantly underestimated time awake (p = 0.001) including wake after sleep onset (WASO) (p = 0.001), and overestimated light sleep (p = 0.045) and total sleep time (TST) (p = 0.001) (paired t-test). Sleep onset and sleep end differed insignificantly from PSG values. Our results suggest that GV4 is not able to reliably describe sleep architecture but may allow for detection of changes in sleep onset, sleep end, and TST (ICC ≥ 0.825) in longitudinally followed groups. Still, generalizations are difficult due to our sample limitations.


Assuntos
Monitorização Ambulatorial/instrumentação , Sono , Dispositivos Eletrônicos Vestíveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial/métodos , Polissonografia/instrumentação , Polissonografia/métodos , Reprodutibilidade dos Testes , Fases do Sono , Fatores de Tempo
2.
Biomed Eng Online ; 18(1): 106, 2019 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-31666082

RESUMO

BACKGROUND: The interplay between sleep structure and seizure probability has previously been studied using electroencephalography (EEG). Combining sleep assessment and detection of epileptic activity in ultralong-term EEG could potentially optimize seizure treatment and sleep quality of patients with epilepsy. However, the current gold standard polysomnography (PSG) limits sleep recording to a few nights. A novel subcutaneous device was developed to record ultralong-term EEG, and has been shown to measure events of clinical relevance for patients with epilepsy. We investigated whether subcutaneous EEG recordings can also be used to automatically assess the sleep architecture of epilepsy patients. METHOD: Four adult inpatients with probable or definite temporal lobe epilepsy were monitored simultaneously with long-term video scalp EEG (LTV EEG) and subcutaneous EEG. In total, 11 nights with concurrent recordings were obtained. The sleep EEG in the two modalities was scored independently by a trained expert according to the American Academy of Sleep Medicine (AASM) rules. By using the sleep stage labels from the LTV EEG as ground truth, an automatic sleep stage classifier based on 30 descriptive features computed from the subcutaneous EEG was trained and tested. RESULTS: An average Cohen's kappa of [Formula: see text] was achieved using patient specific leave-one-night-out cross validation. When merging all sleep stages into a single class and thereby evaluating an awake-sleep classifier, we achieved a sensitivity of 94.8% and a specificity of 96.6%. Compared to manually labeled video-EEG, the model underestimated total sleep time and sleep efficiency by 8.6 and 1.8 min, respectively, and overestimated wakefulness after sleep onset by 13.6 min. CONCLUSION: This proof-of-concept study shows that it is possible to automatically sleep score patients with epilepsy based on two-channel subcutaneous EEG. The results are comparable with the methods currently used in clinical practice. In contrast to comparable studies with wearable EEG devices, several nights were recorded per patient, allowing for the training of patient specific algorithms that can account for the individual brain dynamics of each patient. Clinical trial registered at ClinicalTrial.gov on 19 October 2016 (ID:NCT02946151).


Assuntos
Eletroencefalografia , Epilepsia/fisiopatologia , Processamento de Sinais Assistido por Computador , Fases do Sono , Adulto , Automação , Humanos , Pele
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA