Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
2.
Cont Lens Anterior Eye ; 37(2): 106-10, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24075240

RESUMO

PURPOSE: To study the effects of ocular lubricants on higher order aberrations in normal and self-diagnosed dry eyes. METHODS: Unpreserved hypromellose drops, Tears Again™ liposome spray and a combination of both were administered to the right eye of 24 normal and 24 dry eye subjects following classification according to a 5 point questionnaire. Total ocular higher order aberrations, coma, spherical aberration and Strehl ratios for higher order aberrations were measured using the Nidek OPD-Scan III (Nidek Technologies, Gamagori, Japan) at baseline, immediately after application and after 60 min. The aberration data were analyzed over a 5mm natural pupil using Zernike polynomials. Each intervention was assessed on a separate day and comfort levels were recorded before and after application. Corneal staining was assessed and product preference recorded after the final measurement for each intervention. RESULTS: Hypromellose drops caused an increase in total higher order aberrations (p=<0.01 in normal and dry eyes) and a reduction in Strehl ratio (normal eyes: p=<0.01, dry eyes p=0.01) immediately after instillation. There were no significant differences between normal and self-diagnosed dry eyes for response to intervention and no improvement in visual quality or reduction in higher order aberrations after 60 min. Differences in comfort levels failed to reach statistical significance. CONCLUSION: Combining treatments does not offer any benefit over individual treatments in self-diagnosed dry eyes and no individual intervention reached statistical significance. Symptomatic subjects with dry eye and no corneal staining reported an improvement in comfort after using lubricants.


Assuntos
Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/tratamento farmacológico , Lubrificantes/administração & dosagem , Soluções Oftálmicas/administração & dosagem , Erros de Refração/diagnóstico , Erros de Refração/tratamento farmacológico , Agentes Molhantes/administração & dosagem , Síndromes do Olho Seco/complicações , Feminino , Humanos , Masculino , Projetos Piloto , Valores de Referência , Erros de Refração/etiologia , Resultado do Tratamento , Adulto Jovem
3.
Clin Exp Optom ; 97(2): 160-3, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24024877

RESUMO

BACKGROUND: The aim was to evaluate the validity and repeatability of the auto-refraction function of the Nidek OPD-Scan III (Nidek Technologies, Gamagori, Japan) compared with non-cycloplegic subjective refraction. The Nidek OPD-Scan III is a new aberrometer/corneal topographer workstation based on the skiascopy principle. It combines a wavefront aberrometer, topographer, autorefractor, auto keratometer and pupillometer/pupillographer. METHODS: Objective refraction results obtained using the Nidek OPD-Scan III were compared with non-cycloplegic subjective refraction for 108 eyes of 54 participants (29 female) with a mean age of 23.7 ± 9.5 years. Intra-session and inter-session variability were assessed on 14 subjects (28 eyes). RESULTS: The Nidek OPD-Scan III gave slightly more negative readings than results obtained by subjective refraction (Nidek mean difference -0.19 ± 0.36 DS, p < 0.01 for sphere; -0.19 ± 0.35 DS, p < 0.01 for mean spherical equivalent; -0.002 ± 0.23 DC, p = 0.91 for cylinder; -0.06 ± 0.38 DC, p = 0.30 for J0 and -0.36 ± 0.31 DC for J45, p = 0.29). Auto-refractor results for 74 per cent of spherical readings and 60 per cent of cylindrical powers were within ± 0.25 of subjective refraction. There was high intra-session and inter-session repeatability for all parameters; 90 per cent of inter-session repeatability results were within 0.25 D. CONCLUSION: The Nidek OPD-Scan III gives valid and repeatable measures of objective refraction when compared with non-cycloplegic subjective refraction.


Assuntos
Técnicas de Diagnóstico Oftalmológico/instrumentação , Erros de Refração/diagnóstico , Adulto , Feminino , Humanos , Masculino , Refração Ocular , Reprodutibilidade dos Testes , Acuidade Visual
4.
Surv Ophthalmol ; 57(4): 293-316, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22726587

RESUMO

Dry eye is a common yet complex condition. Intrinsic and extrinsic factors can cause dysfunction of the lids, lacrimal glands, meibomian glands, ocular surface cells, or neural network. These problems would ultimately be expressed at the tear film-ocular surface interface. The manifestations of these problems are experienced as symptoms such as grittiness, discomfort, burning sensation, hyperemia, and secondary epiphora in some cases. Accurate investigation of dry eye is crucial to correct management of the condition. Techniques can be classed according to their investigation of tear production, tear stability, and surface damage (including histological tests). The application, validity, reliability, compatibility, protocols, and indications for these are important. The use of a diagnostic algorithm may lead to more accurate diagnosis and management. The lack of correlation between signs and symptoms seems to favor tear film osmolarity, an objective biomarker, as the best current clue to correct diagnosis.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Síndromes do Olho Seco/diagnóstico , Algoritmos , Humanos , Concentração Osmolar , Lágrimas/química , Lágrimas/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA