Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Neuroradiology ; 62(3): 273-281, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31901972

RESUMO

PURPOSE: To determine whether the sensitivity and specificity of four-dimensional CTA (4D-CTA) are equivalent to digital subtraction angiography (DSA) in the detection of underlying vascular abnormalities in patients with intracerebral haemorrhage (ICH). METHODS: A systematic review of studies comparing 4D-CTA with DSA in the detection of the underlying structural causes of ICH was performed on the literature published between 1998 and 2019. RESULTS: We identified a total of 237 articles from PubMed, SCOPUS and Web of Science using the following Medical Subject Headings (MeSH) terms: primary intracerebral haemorrhage, 4D-CTA, DSA, cerebral haemorrhage, angiography, digital subtraction, arteriovenous malformations, 4D, CTA, dynamic-CTA and time-resolved CTA. Following the removal of duplicate publications and articles failing to meet our inclusion criteria, there were four articles potentially viable for analysis. Therefore, there were not sufficient studies to provide a statistically meaningful meta-analysis. CONCLUSION: The review of current literature has demonstrated that there are few published studies comparing 4D-CTA with DSA in spontaneous ICH, with only four suitable studies identified for potential analysis. However, due to the restricted number of patients and high sensitivity and specificity of 3 studies (100%), performing a meta-analysis was not meaningful. Qualitative analysis of the data concluded that 4D-CTA has the diagnostic potential to replace invasive DSA in certain cases with vascular abnormalities. However, further research studies directly comparing 4D-CTA with DSA using larger prospective patient cohorts are required to strengthen the evidence base.


Assuntos
Angiografia Digital/métodos , Angiografia Cerebral/métodos , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/etiologia , Tomografia Computadorizada Quadridimensional/métodos , Malformações Arteriovenosas Intracranianas/complicações , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Humanos , Sensibilidade e Especificidade
2.
AJNR Am J Neuroradiol ; 37(12): 2189-2194, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27561832

RESUMO

BACKGROUND AND PURPOSE: The novel technique of 4D CTA for dynamic assessment of the intracranial vessels has a greater radiation burden than conventional CTA. Previous descriptions of the technique used a fixed-duration exposure protocol. This study examines the potential for dose reduction by individualizing exposure time to patient physiology by the use of time-enhancement curve techniques as previously applied in CT angiography and venography. MATERIALS AND METHODS: 4D-CTA examinations performed at our institution were retrospectively reviewed. Scan protocols used a test-bolus scan with either a subjective estimate of the main acquisition timing (estimated-duration method) or a quantitative measure (measured-duration method). The estimated-duration method used peak arterial enhancement to determine the start of exposure, with the duration chosen at the radiologist's discretion. The measured-duration method used arterial and venous time-enhancement curves to determine exposure start and duration. Exposure duration, study adequacy, quality score, and maximum venous enhancement were compared among groups. RESULTS: One hundred fifty-one examinations used the estimated-duration method, and 53 used measured-duration. The measured-duration method used a shorter exposure time (10 versus 15.8 seconds; P < .001). There was no statistically significant difference in the study adequacy rate, subjective quality score, or maximum venous enhancement. The radiation dose was reduced by 51% in the measured-duration method (3021 mGy × cm, 6.9 mSv, versus 1473 mGy × cm, 3.4 mSv). Both methods showed good agreement with DSA (κ = 0.88 for estimated-duration, κ = 1.0 for measured duration). CONCLUSIONS: Exposure time in 4D-CTA can be reduced with dual time-enhancement curves to match exposure to physiology without degrading study adequacy or quality.


Assuntos
Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Doses de Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
3.
Clin Radiol ; 66(1): 43-9, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21147298

RESUMO

AIM: To assess the feasibility of producing diagnostic multidetector computed tomography (MDCT) pulmonary angiography with low iodine concentration contrast media (150 mg iodine/ml) in patients with suspected acute pulmonary embolism. MATERIALS AND METHODS: Ninety-five randomized patients underwent MDCT (64 row) pulmonary angiography with 100ml iopromide either at low concentration (LC) of 150 mg iodine/ml (n=45) or high concentration (HC) of 300 mg iodine/ml (n=50), delivered at the rate of 5 ml/s via a power injector. Two experienced radiologists, blinded to the concentration used, subjectively assessed the diagnostic quality and confidence using a four-point scale [1=poor (not diagnostic), 2=satisfactory, 3=good, 4=excellent]. Attenuation values (in HU) were measured in the main proximal branches of the pulmonary arteries. RESULTS: The median diagnostic quality score for both observers was 3.5 (interquartile range 3-4) in the HC group and 2.5 (interquartile range 1.5-3) in the LC group (p<0.01). The median diagnostic confidence score for both observers was 4 (interquartile range 3-4) in the HC group and 3 (interquartile range 1.5-4) in the LC group (p<0.01). Both observers rated examinations as diagnostic in 69% of cases in the LC group, compared with 96% of cases in the HC group. Good interobserver agreement was found in both groups (K value 0.72 in the LC group and 0.73 in the HC). Obesity, poor scan timing, and dilution by venous return of non-opacified blood were the main reasons for a reduction in diagnostic quality of examinations in the LC group. CONCLUSION: Despite a 50% reduction of contrast medium dose in comparison to the standard technique, 150 mg iodine/ml can produce diagnostic MDCT pulmonary angiogram studies in the absence of obesity or high cardiac output and hyper-dynamic pulmonary circulation. Reducing the dose of contrast media would minimize the risk of contrast nephropathy in patients at risk of this complication, particularly those suffering from congestive heart failure in whom intravenous hydration is contraindicated.


Assuntos
Meios de Contraste , Iodo , Iohexol/análogos & derivados , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/administração & dosagem , Estudos de Viabilidade , Feminino , Humanos , Iodo/administração & dosagem , Iohexol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Artéria Pulmonar/fisiopatologia , Embolia Pulmonar/fisiopatologia , Sensibilidade e Especificidade , Adulto Jovem
4.
AJNR Am J Neuroradiol ; 31(3): 436-41, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19875467

RESUMO

BACKGROUND AND PURPOSE: CP is a common feature of perinatal HIBD in the context of "acute profound" injury, and in this article, we have studied the possible anatomic substrates of dyskinesia. We have reviewed the extent of brain injury in children with dyskinetic and spastic CP due to acute profound hypoxia to identify sites of injury that explain why only some children develop movement disorders. It is known that the STN has a role in the development of movement disorders; therefore, we have specifically studied it. MATERIALS AND METHODS: We retrospectively reviewed MR imaging of 40 consecutive children referred to our center with CP confirmed to be due to acute profound hypoxic-ischemic injury. All children received the same high-resolution MR imaging protocol with the same 1.5T scanner. Two pediatric neuroradiologists reviewed the imaging. Logistic regression was applied to identify multivariable predictors that differentiate dyskinetic and spastic CP. RESULTS: Twenty children had dyskinetic CP and 20 had spastic CP. Children with dyskinetic CP had more frequent injury to the STN, as manifest by increased T2 signal intensity. Children with spastic CP had more severe damage to white matter in the vicinity of the paracentral lobule. Injuries to the putamen, caudate, and globus pallidus were not significant predictors of dyskinesia. CONCLUSIONS: We have shown an association between hypoxic-ischemic injury to the STN at birth and the emergence of dyskinesia later in life.


Assuntos
Paralisia Cerebral/patologia , Hipóxia-Isquemia Encefálica/patologia , Imageamento por Ressonância Magnética , Prosencéfalo/patologia , Algoritmos , Criança , Pré-Escolar , Corpo Estriado/patologia , Humanos , Lactente , Modelos Logísticos , Análise Multivariada , Fibras Nervosas Mielinizadas/patologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Núcleo Subtalâmico/patologia , Núcleos Talâmicos/patologia
SELEÇÃO DE REFERÊNCIAS