Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Acta Otolaryngol ; 137(10): 1090-1095, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28598713

RESUMO

BACKGROUND: Having one hand occupied with the endoscope is the major disadvantage for the surgeon when it comes to functional endoscopic sinus surgery (FESS). Only the other hand is free to use the surgical instruments. Tiredness or frequent instrument changes can thus lead to shaky endoscopic images. METHODS: We collected the pose data (position and orientation) of the rigid 0° endoscope and all the instruments used in 16 FESS procedures with manual endoscope guidance as well as robot-assisted endoscope guidance. In combination with the DICOM CT data, we tracked the endoscope poses and workspaces using self-developed tracking markers. RESULTS: All surgeries were performed once with the robot and once with the surgeon holding the endoscope. Looking at the durations required, we observed a decrease in the operating time because one surgeon doing all the procedures and so a learning curve occurred what we expected. The visual inspection of the specimens showed no damages to any of the structures outside the paranasal sinuses. CONCLUSION: Robot-assisted endoscope guidance in sinus surgery is possible. Further CT data, however, are desirable for the surgical analysis of a tracker-based navigation within the anatomic borders. Our marker-based tracking of the endoscope as well as the instruments makes an automated endoscope guidance feasible. On the subjective side, we see that RASS brings a relief for the surgeon.


Assuntos
Endoscópios , Endoscopia , Seios Paranasais/cirurgia , Procedimentos Cirúrgicos Robóticos , Humanos , Modelos Anatômicos , Duração da Cirurgia
2.
Int J Med Robot ; 11(1): 30-7, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24941911

RESUMO

BACKGROUND: For the further development of robot-assisted endoscope guidance in functional endoscopic sinus surgery (FESS), ground data about the workspaces and endoscope movements in conventional FESS are needed. METHODS: Applying a self-developed marker-based tracking system, we collected the pose data (position and orientation) of the endoscope and all other instruments used in five real sinus surgeries. RESULTS: The automated segmentation of the endoscope poses shows the shape of a hourglass, with a pivot region or pivot point at the 'waistline' of the hourglass, close to the nasal entrance in the nasal dome. CONCLUSION: We were able to identify a pivot point at the waistline of the segmented endoscope poses. The size of the pivot point corresponds with the diameter of the 4 mm endoscope. Because of the reduction to four degrees of freedom for endoscope motions (three rotations and one translation), easier and safer robot-assisted endoscope guidance becomes feasible.


Assuntos
Endoscopia/métodos , Seios Paranasais/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Endoscópios , Estudos de Viabilidade , Humanos , Seios Paranasais/patologia , Procedimentos Cirúrgicos Robóticos/instrumentação , Cirurgia Assistida por Computador/métodos
3.
Eur Arch Otorhinolaryngol ; 265(9): 1061-70, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18253744

RESUMO

Manual segmentation is often used for evaluation of automatic or semi-automatic segmentation. The purpose of this paper is to describe the inter and intraindividual variability, the dubiety of manual segmentation as a gold standard and to find reasons for the discrepancy. We realized two experiments. In the first one ten ENT surgeons, ten medical students and one engineer outlined the right maxillary sinus and ethmoid sinuses manually on a standard CT dataset of a human head. In the second experiment two participants outlined maxillary sinus and ethmoid sinuses five times consecutively. Manual segmentation was accomplished with custom software using a line segmentation tool. The first experiment shows the interindividual variability of manual segmentation which is higher for ethmoidal sinuses than for maxillary sinuses. The variability can be caused by the level of experience, different interpretation of the CT data or different levels of accuracy. The second experiment shows intraindividual variability which is lower than interindividual variability. Most variances in both experiments appear during segmentation of ethmoidal sinuses and outlining hiatus semilunaris. Concerning the inter and intraindividual variances the segmentation result of one manual segmenter could not directly be used as gold standard for the evaluation of automatic segmentation algorithms.


Assuntos
Seios Paranasais/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Adulto , Feminino , Humanos , Imageamento Tridimensional , Masculino , Reprodutibilidade dos Testes , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA