Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Prog Transplant ; 30(4): 376-381, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32985349

RESUMO

BACKGROUND: Ventricular assist device (VAD) patients are at high risk for morbidities and mortality. One potentially beneficial component of the Joint Commission VAD Certification process is the requirement that individual VAD programs select 4 performance measures to improve and optimize patients' clinical outcomes. PROBLEM STATEMENT: Review of patient data after our program's first certification visit in 2008 showed that, compared to national recommendations and published reports, our patients had suboptimal outcomes in 4 areas after device implantation: length of hospital stay, receipt of early (<48 hours) postsurgical physical therapy, driveline infection incidence, and adequacy of nutritional status (prealbumin ≥18 mg/dL). METHODS: Plan-Do-Study-Act processes were implemented to shorten length of stay, increase patient receipt of early physical therapy, decrease driveline infection incidence, and improve nutritional status. With 2008 as our baseline, we deployed interventions for each outcome area across 2009 to 2017. Performance improvement activities included staff, patient, and family didactic, one-on-one, and hands-on education; procedural changes; and outcomes monitoring with feedback to staff on progress. Descriptive and inferential statistics were examined to document change in the outcomes. OUTCOMES: Across the performance improvement period, length of stay decreased from 40 to 23 days; physical therapy consults increased from 87% to 100% of patients; 1-year driveline infection incidence went from 38% to 23.5%; and the percentage of patients with prealbumin within the normal range increased from 84% to 90%. IMPLICATIONS: Performance improvement interventions may enhance ventricular assist device patient outcomes. Interventions' sustainability should be evaluated to ensure that gains are not lost over time.


Assuntos
Procedimentos Cirúrgicos Cardíacos/normas , Coração Auxiliar/normas , Tempo de Internação/estatística & dados numéricos , Modalidades de Fisioterapia/normas , Guias de Prática Clínica como Assunto , Melhoria de Qualidade/normas , Disfunção Ventricular/cirurgia , Adulto , Idoso , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Pré-Albumina/análise , Estudos Retrospectivos , Resultado do Tratamento , Estados Unidos
2.
J Clin Monit Comput ; 32(1): 33-43, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28188408

RESUMO

We compared the similarity of cardiac-output (CO) estimates between available bolus thermodilution pulmonary-artery catheters (PAC), arterial pulse-contour analysis (LiDCOplus™, FloTrac™ and PiCCOplus™), and bioreactance (NICOM™). Repetitive simultaneous estimates of CO obtained from the above devices were compared in 21 cardiac-surgery patients during the first 2 h post-surgery. Mean and absolute values for CO across the devices were compared by ANOVA, Bland-Altman, Pearson moment, and linear-regression analyses. Twenty-one simultaneous CO measurements were made before and after therapeutic interventions. Mean PAC CO (5.7 ± 1.5 L min) was similar to LiDCO™, FloTrac™, PiCCO™, and NICOM™ CO (6.0 ± 1.9, 5.9 ± 1.0, 5.7 ± 1.8, 5.3 ± 1.0 L min, respectively). Mean CO bias between each paired method was -0.10 (PAC-LiDCO), 0.18 (PAC-PiCCO), -0.40 (PAC-FloTrac), -0.71 (PAC-NICOM), 0.28 (LiDCO-PiCCO), 0.39 (LiDCO-FloTrac), -0.97 (NICOM-LiDCO), 0.61 (PiCCO-FloTrac), -1.0 (NICOM-FloTrac), -0.73 (NICOM-PiCCO) L/min, with limits of agreement (1.96 SD, ±95% CI) of ± 2.01, ±2.35, ±2.27, ±2.70, ±1.97, ±2.17, ±3.51, ±2.87, ±2.40, and ± 3.14 L min, respectively, and the percentage error for each of the paired devices was 35, 41, 40, 47, 33, 36, 59, 50, 42, and 55%, respectively. From Pearson moment analysis, dynamic changes in CO, estimated by each device, showed good cross-correlations. Although all devices studied recorded similar mean CO values, which dynamically changed in similar directions, they have markedly different bias and precision values relative to each other. Thus, results from prior studies that have used one device to estimate CO cannot be used to validate others devices.


Assuntos
Débito Cardíaco , Procedimentos Cirúrgicos Cardíacos/instrumentação , Cateterismo de Swan-Ganz/instrumentação , Cateterismo de Swan-Ganz/métodos , Frequência Cardíaca , Artéria Pulmonar , Termodiluição/métodos , Idoso , Algoritmos , Análise de Variância , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Período Pós-Operatório , Reprodutibilidade dos Testes , Fatores de Tempo
3.
Prog Transplant ; 23(1): 28-32, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23448817

RESUMO

A patient with a HeartMate II left ventricular assist device who had a body mass index of 52 needed gastric bypass surgery in order to qualify for a heart transplant. Unlike previous experience in which the surgery was performed at the implant hospital, the gastric bypass surgery in this case was performed at a bariatric center of excellence that was a separate facility from the implant hospital. The artificial heart program of the University of Pittsburgh Medical Center worked with the bariatric center of excellence in scheduling the gastric bypass surgery using a multidisciplinary team approach at 2 hospitals to coordinate safe, high-quality patient care in a unique situation.


Assuntos
Derivação Gástrica , Coração Auxiliar , Planejamento de Assistência ao Paciente , Adulto , Insuficiência Cardíaca/cirurgia , Transplante de Coração , Humanos , Masculino , Obesidade Mórbida/cirurgia , Pennsylvania , Assistência Perioperatória
4.
Prog Transplant ; 23(1): 39-46, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23448819

RESUMO

Ventricular assist devices provide therapeutic options for patients with severe heart failure who have exhausted available medical therapies. With restoration of organ perfusion with ventricular assist devices, the heart failure resolves and quality of life and functional status improve. The current generation of continuous-flow devices present novel challenges to the clinical assessment of patients by substantially reducing or nearly eliminating any palpable pulse. Patients therefore generally have inadequate arterial pulsatility for most noninvasive monitoring devices such as pulse oximeters or automated blood pressure cuffs to work accurately. This article describes the function of continuous-flow devices and how this function affects common monitoring options, as well as how to clinically assess recipients of continuous-flow devices to promptly identify those whose condition may be deteriorating or who may be receiving inadequate perfusion.


Assuntos
Determinação da Pressão Arterial/métodos , Testes de Função Cardíaca/métodos , Coração Auxiliar , Monitorização Fisiológica/métodos , Determinação da Pressão Arterial/enfermagem , Eletrocardiografia/métodos , Eletrocardiografia/enfermagem , Testes de Função Cardíaca/enfermagem , Frequência Cardíaca , Humanos , Monitorização Fisiológica/enfermagem , Oximetria , Ultrassonografia Doppler
5.
J Crit Care ; 26(3): 328.e1-8, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21036528

RESUMO

INTRODUCTION: Although pulse pressure variation (PPV) and stroke volume variation (SVV) during mechanical ventilation have been shown to predict preload responsiveness, the effect of vasoactive therapy on PPV and SVV is unknown. METHODS: Pulse pressure variation and SVV were measured continuously in 15 cardiac surgery patients for the first 4 postoperative hours. Pulse pressure variation was directly measured from the arterial pressure waveform, and both PPV and SVV were also calculated by LiDCO Plus (LiDCO Ltd, Cambridge, United Kingdom) before and after volume challenges or changes in vasoactive drug infusions done to sustain cardiovascular stability. RESULTS: Seventy-one paired events were studied (38 vasodilator, 10 vasoconstrictor, 14 inotropes, and 9 volume challenges). The difference between the measured and LiDCO-calculated PPV was 1% ± 7% (1.96 SD, 95% confidence interval, r(2) = 0.8). Volume challenge decreased both PPV and SVV (15% to 10%, P < .05 and 13% to 9%, P = .09, respectively). Vasodilator therapy increased PPV and SVV (13% to 17% and 9% to 15%, respectively, P < .001), whereas increasing inotropes or vasoconstrictors did not alter PPV or SVV. The PPV/SVV ratio was unaffected by treatments. CONCLUSION: Volume loading decreased PPV and SVV; and vasodilators increased both, consistent with their known cardiovascular effects. Thus, SVV and PPV can be used to drive fluid resuscitation algorithms in the setting of changing vasoactive drug therapy.


Assuntos
Pressão Sanguínea/efeitos dos fármacos , Respiração Artificial , Volume Sistólico/efeitos dos fármacos , Vasoconstritores/farmacologia , Vasodilatadores/farmacologia , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardiovasculares , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios , Fatores de Tempo
6.
Crit Care ; 14(6): R212, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21092290

RESUMO

INTRODUCTION: Although less invasive than pulmonary artery catheters (PACs), arterial pulse pressure analysis techniques for estimating cardiac output (CO) have not been simultaneously compared to PAC bolus thermodilution CO (COtd) or continuous CO (CCO) devices. METHODS: We compared the accuracy, bias and trending ability of LiDCO™, PiCCO™ and FloTrac™ with PACs (COtd, CCO) to simultaneously track CO in a prospective observational study in 17 postoperative cardiac surgery patients for the first 4 hours following intensive care unit admission. Fifty-five paired simultaneous quadruple CO measurements were made before and after therapeutic interventions (volume, vasopressor/dilator, and inotrope). RESULTS: Mean CO values for PAC, LiDCO, PiCCO and FloTrac were similar (5.6 ± 1.5, 5.4 ± 1.6, 5.4 ± 1.5 and 6.1 ± 1.9 L/min, respectively). The mean CO bias by each paired method was -0.18 (PAC-LiDCO), 0.24 (PAC-PiCCO), -0.43 (PAC-FloTrac), 0.06 (LiDCO-PiCCO), -0.63 (LiDCO-FloTrac) and -0.67 L/min (PiCCO-FloTrac), with limits of agreement (1.96 standard deviation, 95% confidence interval) of ± 1.56, ± 2.22, ± 3.37, ± 2.03, ± 2.97 and ± 3.44 L/min, respectively. The instantaneous directional changes between any paired CO measurements displayed 74% (PAC-LiDCO), 72% (PAC-PiCCO), 59% (PAC-FloTrac), 70% (LiDCO-PiCCO), 71% (LiDCO-FloTrac) and 63% (PiCCO-FloTrac) concordance, but poor correlation (r(2) = 0.36, 0.11, 0.08, 0.20, 0.23 and 0.11, respectively). For mean CO < 5 L/min measured by each paired devices, the bias decreased slightly. CONCLUSIONS: Although PAC (COTD/CCO), FloTrac, LiDCO and PiCCO display similar mean CO values, they often trend differently in response to therapy and show different interdevice agreement. In the clinically relevant low CO range (< 5 L/min), agreement improved slightly. Thus, utility and validation studies using only one CO device may potentially not be extrapolated to equivalency of using another similar device.


Assuntos
Cateterismo Cardíaco/normas , Débito Cardíaco/fisiologia , Cateterismo de Swan-Ganz/normas , Artéria Pulmonar/fisiologia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Cateterismo de Swan-Ganz/métodos , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Termodiluição/métodos , Termodiluição/normas
7.
Prog Transplant ; 20(2): 155-62, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20642174

RESUMO

The Centers for Medicare and Medicaid Services announced that all hospitals implanting ventricular assist devices are required to have certification from the The Joint Commission for disease-specific care destination therapy with a ventricular assist device effective March 27, 2009, in order to receive Medicare reimbursement for services rendered to patients who have devices implanted for destination therapy. On February 23, 2007, The Joint Commission released the certification requirements for ventricular assist devices implanted for destination therapy in an 8-page document so that hospitals could prepare to meet the 2009 certification deadline. The Artificial Heart Program of the University of Pittsburgh Medical Center undertook a multidisciplinary project, under the guidance of the nurse coordinator, to prepare the hospital and program for a precertification survey by The Joint Commission for disease-specific destination therapy ventricular assist device certification. The Presbyterian Hospital Artificial Heart Program was awarded The Joint Commission's device-specific certification for destination therapy with ventricular assist devices in June 2008.


Assuntos
Institutos de Cardiologia/normas , Certificação , Coração Auxiliar , Implantação de Prótese/normas , Humanos , Capacitação em Serviço , Joint Commission on Accreditation of Healthcare Organizations , Medicare , Pennsylvania , Guias de Prática Clínica como Assunto , Desenvolvimento de Programas , Indicadores de Qualidade em Assistência à Saúde , Estados Unidos
8.
Crit Care Med ; 36(11): 3001-7, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18824912

RESUMO

INTRODUCTION: Measures of arterial pulse pressure variation and left ventricular stroke volume variation induced by positive-pressure breathing vary in proportion to preload responsiveness. However, the accuracy of commercially available devices to report dynamic left ventricular stroke volume variation has never been validated. METHODS: We compared the accuracy of measured arterial pulse pressure and estimated left ventricular stroke volume reported from two Food and Drug Administration-approved aortic flow monitoring devices, one using arterial pulse power (LiDCOplus) and the other esophageal Doppler monitor (HemoSonic). We compared estimated left ventricular stroke volume and their changes during a venous occlusion and release maneuver to a calibrated aortic flow probe placed around the aortic root on a beat-to-beat basis in seven anesthetized open-chested cardiac surgery patients. RESULTS: Dynamic changes in arterial pulse pressure closely tracked left ventricular stroke volume changes (mean r .96). Both devices showed good agreement with steady-state apneic left ventricular stroke volume values and moderate agreement with dynamic changes in left ventricular stroke volume (esophageal Doppler monitor -1 +/- 22 mL, and pulse power -7 +/- 12 mL, bias +/- 2 sd). In general, the pulse power signals tended to underestimate left ventricular stroke volume at higher left ventricular stroke volume values. CONCLUSION: Arterial pulse pressure, as well as, left ventricular stroke volume estimated from esophageal Doppler monitor and pulse power reflects short-term steady-state left ventricular stroke volume values and tract dynamic changes in left ventricular stroke volume moderately well in humans.


Assuntos
Pressão Sanguínea/fisiologia , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Volume Sistólico/fisiologia , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Pulso Arterial
9.
J Trauma ; 63(3): 573-8; discussion 578-80, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18073603

RESUMO

BACKGROUND: A rapid, reliable, and noninvasive functional measure of responsiveness to resuscitation in posttraumatic hemorrhagic shock could prove useful in guiding therapy, especially under circumstances such as the battlefield and civilian mass casualties. Tissue oxygen saturation (Sto2) is a promising candidate for this application. We therefore explored the value of peripheral muscle Sto2 in predicting systemic responsiveness to colloid volume resuscitation in a porcine model of hemorrhagic shock. METHODS: Fourteen isoflurane-anesthetized piglets were subjected to a standardized hemorrhage protocol that maintained mean arterial pressure (MAP) between 30 and 40 mm Hg. Asanguineous resuscitation with a volume of Hextend equal to the total volume bled was initiated when compensation was exhausted (MAP <30 mm Hg). We recorded continuous MAP and Sto2 values, and calculated the contiguous area over the Sto2 curve yet below a given threshold of Sto2 (TAOC) as a function of this threshold before the selected timepoint for timepoints up to 30 minutes before resuscitation. RESULTS: Hemorrhage resulted in significant fluctuations of MAP and high interindividual variability of disease dynamics and outcome: 4 nonsurvivors and 10 survivors at 2 hours postresuscitation. Sto2 measurements reflected hemodynamic conditions in most animals, with a pronounced drop preceding final decompensation in 7 of 14 animals. TAOC discriminated three of four nonresuscitable (nonsurvivor) animals from the survivors, with group differences reaching significance even for the earliest examined timepoint (30 minutes before resuscitation), depending on the choice of TAOC threshold. CONCLUSIONS: Sto2 may serve as a marker of decompensation, whereas TAOC, a physiologically motivated correlate of perfusion debt and cumulative hypoperfusion injury, may be a useful early indicator of responsiveness to volume resuscitation in hemorrhagic shock.


Assuntos
Oxigênio/metabolismo , Ressuscitação/métodos , Choque Hemorrágico/terapia , Animais , Área Sob a Curva , Hemodinâmica , Valor Preditivo dos Testes , Curva ROC , Análise Espectral/métodos , Estatísticas não Paramétricas , Suínos
10.
J Am Soc Echocardiogr ; 19(5): 475-82, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16644429

RESUMO

Our objective was to test the hypothesis that novel angle-corrected radial strain imaging can quantify left ventricular dyssynchrony associated with contractile impairment and improved with biventricular pacing. Eight open-chest dogs were studied by novel angle-corrected color-coded radial strain imaging and high-fidelity pressure-conductance catheters recording pressure-volume loops. Heart rate was controlled by right atrial pacing and all timing intervals were corrected by R-R interval (corrected interval = measured interval/(R-R interval)(1/2)). Left bundle branch block, simulated by right ventricular free wall pacing, resulted in marked radial dyssynchrony, which we defined as maximal time difference between peak segmental strain, from 39 +/- 17 to 354 +/- 49 milliseconds and stroke work decreased from 157 +/- 40 to 60 +/- 37 mJ, (P < .005 vs baseline). Depression of contractility by high-dose esmolol (end-systolic pressure-volume relationship from 5.7 +/- 2.4 to 3.6 +/- 1.0 mm Hg/mL) was associated with augmented dyssynchrony to 388 +/- 53 milliseconds (P < .05 vs baseline right ventricular pacing). Biventricular pacing improved dyssynchrony to 55 +/- 19 milliseconds and stroke work to 143 +/- 33 mJ (P < .05 vs right ventricular pacing). Changes in radial dyssynchrony correlated significantly with 6-site average regional strain (r = -0.93 +/- 0.05 individually, r = 0.80 overall) and stroke work (r = -0.88 +/- 0.12 individually, r = -0.82 overall). Angle-corrected radial strain imaging has clinical potential to quantify mechanical dyssynchrony and effects of biventricular pacing.


Assuntos
Estimulação Cardíaca Artificial , Ecocardiografia Doppler/métodos , Interpretação de Imagem Assistida por Computador/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Fibrilação Ventricular/diagnóstico por imagem , Fibrilação Ventricular/prevenção & controle , Animais , Cães , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia , Fibrilação Ventricular/complicações
11.
Am J Cardiol ; 96(1): 141-7, 2005 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-15979454

RESUMO

The application of angle correction to tissue Doppler (TD) during dobutamine stress echocardiography (DSE) extends the application of TD to all left ventricular segments, improves the differentiation of abnormal from normal segmental responses to stress, and has promise to improve its clinical utility for objectively evaluating wall motion during DSE.


Assuntos
Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Ecocardiografia sob Estresse , Função Ventricular Esquerda , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Chest ; 126(6): 1910-8, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15596692

RESUMO

STUDY OBJECTIVES: Early diastolic mitral annular velocity (E') by tissue Doppler echocardiography (TD) has been reported to be a load-independent index of left ventricular (LV) diastolic function, allowing the early diastolic mitral inflow velocity (E)/E' ratio to be used clinically to predict LV filling pressures. However, preload independence of E' has remained controversial, and E/E' may not consistently be predictive of LV filling pressures. Our objectives were to test the hypotheses that E' is affected by preload, and that alterations of preload, afterload, and contractility also affect E/E'. DESIGN, INTERVENTIONS, AND MEASUREMENTS: An open-chest dog model was used (n = 8). High-fidelity pressure and conductance catheters were used for pressure-volume relations, and E' was obtained by pulsed TD from the apical four-chamber view. Changes in preload and afterload were induced by vena caval and partial aortic occlusions, respectively. Data were collected during control phase and during infusions of dobutamine and esmolol to alter contractility. RESULTS: E' was consistently and significantly associated with acute decreases in LV end-diastolic pressure in each dog (n = 200 beats; r = 0.93 +/- 0.06 [mean +/- SD]). Similar results occurred with dobutamine and esmolol infusions. This preload sensitivity was reflected in E/E', which was inversely (rather than directly) correlated with LV diastolic pressure (r = - 0.67). E/E' was less affected by preload when diastolic dysfunction was induced by sustained partial aortic occlusion (time constant of relaxation increased from 46 +/- 19 to 53 +/- 21 ms, p < 0.001). CONCLUSIONS: E' was significantly influenced by preload with preserved LV function and low filling pressures (< 12 mm Hg); accordingly, E/E' was less predictive of LV filling pressures in this scenario. E/E' was more predictive of LV filling pressures in the presence of diastolic dysfunction.


Assuntos
Ecocardiografia Doppler , Valva Mitral/fisiologia , Função Ventricular Esquerda , Animais , Aorta/fisiologia , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Diástole , Dobutamina/farmacologia , Cães , Hemodinâmica , Masculino , Valva Mitral/diagnóstico por imagem , Contração Miocárdica/efeitos dos fármacos , Propanolaminas/farmacologia , Volume Sistólico , Veia Cava Inferior/fisiologia , Pressão Ventricular
13.
Am J Cardiol ; 94(4): 514-8, 2004 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-15325944

RESUMO

Cardiac resynchronization therapy has made assessment of cardiac dyssynchrony clinically important. To test the hypothesis that echocardiographic displacement imaging can quantify dyssynchrony, 22 patients with left bundle branch block (LBBB), 14 with idiopathic dilated cardiomyopathy (IDC) without electrical conduction delay, and 22 normal controls were studied using radial angle-corrected displacement imaging. Control subjects had coordinated wall movement, whereas patients with LBBB had dyssynchrony characterized by early inward anteroseptal movement and markedly delayed posterior, lateral, or inferior regions (157 +/- 99 ms; p <0.001 vs normal). An interesting subset of patients with IDC without conduction delay (36%) had dyssynchrony with anteroseptal to posterior wall delays of 169 +/- 56 ms (p <0.001 vs normal), similar to patients with LBBB.


Assuntos
Bloqueio de Ramo/diagnóstico por imagem , Cardiomiopatia Dilatada/diagnóstico por imagem , Ecocardiografia Doppler em Cores , Ecocardiografia , Eletrocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Contração Miocárdica/fisiologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Cardiomiopatia Dilatada/fisiopatologia , Cardiomiopatia Dilatada/terapia , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/fisiopatologia , Doença das Coronárias/terapia , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda/fisiologia
14.
J Surg Res ; 121(1): 31-7, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15313372

RESUMO

This study addresses the hypothesis that exposure to peripheral arterial (ART) or coronary (COR) hemodynamics and wall biomechanics affect platelet deposition on vein segments. Intact human saphenous vein (HSV) and porcine internal jugular vein (PIJV) segments were studied under venous (VEN), ART, and COR environments using in vitro perfusion systems. Wall shear stress (tau) and circumferential wall stress (sigma(theta)) were calculated for PIJV segments. Platelet deposition was measured using a radioactive assay. PIJV ART segments exhibited a 14% increase in inner diameter over time (P < 0.05). tau, acting on PIJV ART specimens, was less at 6 h compared with time 0 (P < 0.05). sigma(theta) was lower in the VEN specimens compared with ART and COR groups (P < 0.01). Platelet deposition decreased by 40% on PIJV ART segments (P < 0.05) but increased 3.2-fold on PIJV COR segments (P < 0.05) versus VEN control segments. Platelet deposition was increased 1.75-fold in COR HSV cases versus VEN segments. These data indicate that short-term exposure to COR conditions lead to enhanced platelet deposition, whereas ART conditions decrease platelet deposition.


Assuntos
Hemodinâmica/fisiologia , Veias Jugulares/fisiologia , Veia Safena/fisiologia , Trombose Venosa/etiologia , Animais , Fenômenos Biomecânicos , Plaquetas/fisiologia , Humanos , Óxido Nítrico/fisiologia , Perfusão , Suínos
15.
J Heart Lung Transplant ; 22(12): 1304-13, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14672744

RESUMO

BACKGROUND: Myocardial recovery may occur in patients with heart failure who are receiving left ventricular assist-device support, but identification of candidates for device removal remains challenging. We hypothesized that on-line quantitative echocardiography during trials of decreased device support alone or in combination with exercise cardiopulmonary testing can assess cardiac recovery to predict successful device removal. METHODS: We studied 18 patients with severe heart failure, aged 45 +/- 19 years, who received 234 +/- 169 days of assist-device support as a bridge to transplantation. We used echocardiographic automated border detection from mid-ventricular short-axis images and non-invasive arterial pressure to measure beat-to-beat responses in 2 to 5 minute trials of decreased device flow. We also assessed maximal oxygen consumption in 14 patients who could exercise. RESULTS: Six patients experienced myocardial recovery and underwent successful device removal; 12 remained device dependent. With transient, low assist-device flow, patients with device removal had increased echocardiographic stroke area of 27% +/- 36% vs -24% +/- 12% (p < 0.05) and fractional area change of 51% +/- 13% vs 23% +/- 11% (p < 0.05) in the patients who were device dependent. Estimates of pre-load-adjusted maximal power, a relatively load-independent index, were 6.7 +/- 2.1 mW/cm(4) in patients with successful device removal vs 1.2 +/- 1.2 mW/cm(4) in patients who were device dependent (p < 0.005). Maximal oxygen consumption was 17.2 +/- 1.4 ml/kg/min in patients with myocardial recovery vs 13.1 +/- 1.9 ml/kg/min in patients who were device dependent (p < 0.005) and correlated with pre-load-adjusted maximal power (r = 0.89, p < 0.001). Maximal oxygen consumption >16 ml/kg/min, increased stroke area, >40% increase in fractional area change, or pre-load-adjusted maximal power >4.0 mW/cm(4) with low device flow were associated with successful device removal (p < 0.05). CONCLUSIONS: On-line quantitative echocardiography alone or combined with exercise cardiopulmonary testing can assess myocardial recovery of patients receiving left ventricular assist-device support and has the potential to identify patients who are clinical candidates for device removal.


Assuntos
Ecocardiografia Transesofagiana/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Coração Auxiliar , Função Ventricular Esquerda/fisiologia , Adulto , Remoção de Dispositivo , Teste de Esforço , Feminino , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Sistemas On-Line , Recuperação de Função Fisiológica/fisiologia , Resultado do Tratamento
16.
Am J Cardiol ; 92(6): 752-5, 2003 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-12972128

RESUMO

Cardiac resynchronization therapy (CRT) can improve cardiac function in patients with heart failure and left bundle branch block. To test a new synchrony index derived from mitral annular velocity by color tissue Doppler, 19 subjects were studied: 9 patients with heart failure and left bundle branch block at baseline and at 1, 3 and 6 months after CRT and 10 normal controls. The synchrony index in patients with heart failure was less than that in controls at baseline (r = 0.60 +/- 0.13 vs 0.94 +/- 0.02; p <0.01), but improved at 6 months after CRT (r = 0.77 +/- 0.09; p <0.05 vs baseline).


Assuntos
Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial , Ecocardiografia Doppler em Cores , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/terapia , Idoso , Bloqueio de Ramo/fisiopatologia , Feminino , Seguimentos , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Reprodutibilidade dos Testes , Fatores de Tempo , Disfunção Ventricular Esquerda/fisiopatologia
17.
Am J Cardiol ; 92(5): 554-60, 2003 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-12943876

RESUMO

To test the hypothesis that a new tissue Doppler (TD) approach using angle-correction and transformation of velocity data to color-coded displacement data may objectively quantify regional left ventricular function, in vitro experiments were first performed with an oscillating echo target precisely controlled by a microstepping motor. Displacement varied from 1 to 15 mm (60 to 130 cycles/min) at angles of 0 degrees and 45 degrees to the echo transducer. Custom software transformed TD data to displacement data. Sixty-five subjects were then studied: 35 with wall motion abnormalities and 30 normal controls. Results were compared with independent visual assessment and caliper measurements of endocardial excursion from gray-scale images. In vitro displacement imaging strongly correlated with true displacement (r = 0.99, p <0.0001). In humans, peak transmural displacement discriminated normal results (6.3 +/- 3.2 mm) from hypokinesia (2.7 +/- 1.8 mm, p <0.05), akinesia (0.4 +/- 1.2 mm, p <0.05) from hypokinesia, and dyskinesia (-1.9 +/- 1.2 mm, p <0.05) from akinesia. Normal subendocardial displacement was 5.9 +/- 2.9 versus 4.0 +/- 3.9 mm in the epicardial layer (p <0.01). This displacement gradient was absent in abnormal segments. Displacement data correlated with endocardial excursion by calipers (parasternal views: r = 0.86, all views: r = 0.79, both p <0.0001). Overall accuracy of displacement imaging was 82% (kappa = 0.71) versus 66% (kappa = 0.43) for visual assessment with caliper data as the standard of reference. Angle-corrected displacement imaging was superior to routine visual assessment and is a promising new method to quantify regional left ventricular function.


Assuntos
Ecocardiografia Doppler em Cores/métodos , Processamento de Imagem Assistida por Computador/normas , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Análise de Variância , Cardiomiopatia Dilatada/complicações , Estudos de Casos e Controles , Doença das Coronárias/complicações , Análise Discriminante , Ecocardiografia Doppler em Cores/normas , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Análise dos Mínimos Quadrados , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador , Método Simples-Cego , Software/normas , Sístole , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA