Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Can Prosthet Orthot J ; 5(1): 37795, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-37614478

RESUMO

BACKGROUND: Patients with neuromuscular knee-instability assisted with orthotic devices experience problems including pain, falls, mobility issues and limited engagement in daily activities. OBJECTIVES: The aim of this study was to analyse current real-life burden, needs and orthotic device outcomes in patients in need for advanced orthotic knee-ankle-foot-orthoses (KAFOs). METHODOLOGY: An observer-based semi-structured telephone interview with orthotic care experts in Germany was applied. Interviews were transcribed and content-analysed. Quantitative questions were analysed descriptively. FINDINGS: Clinical experts from eight centres which delivered an average of 49.9 KAFOs per year and 13.3 microprocessor-stance-and-swing-phase-controlled-knee-ankle-foot orthoses (MP-SSCOs) since product availability participated. Reported underlying conditions comprised incomplete paraplegia (18%), peripheral nerve lesions (20%), poliomyelitis (41%), post-traumatic lesions (8%) and other disorders (13%). The leading observed patient burdens were "restriction of mobility" (n=6), followed by "emotional strain" (n=5) and "impaired gait pattern" (n=4). Corresponding results for potential patient benefits were seen in "improved quality-of-life" (n=8) as well as "improved gait pattern" (n=8) followed by "high reliability of the orthosis" (n=7). In total, experts reported falls occurring in 71.5% of patients at a combined annual frequency of 7.0 fall events per year when using KAFOs or stance control orthoses (SCOs). In contrast, falls were observed in only 7.2 % of MPSSCO users. CONCLUSION: Advanced orthotic technology might contribute to better quality of life of patients, improved gait pattern and perceived reliability of orthosis. In terms of safety a substantial decrease in frequency of falls was observed when comparing KAFO and MP-SSCO users.

2.
Orthopade ; 40(7): 585-90, 2011 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-21374098

RESUMO

A key element of patient care after hip and knee replacement is medication-based thrombosis prophylaxis. Due to decreasing lengths of acute hospital stays the question arises to what extent outpatients are taking responsibility thrombosis prophylaxis (patient pathway analysis).To analyze patient pathways a telephone survey of 668 patients was conducted. On average patients were interviewed 38 days following surgery with a focus on low molecular weight heparins. The analysis showed that nearly 90% of patients need to carry out thrombosis prophylaxis in an outpatient or home environment for at least 1 day and for 47.2% of patients a linking period between acute and rehabilitation stay is relevant. The obviously existing quantitative importance of outpatient thrombosis prophylaxis is also reflected by its duration and 45.7% of interviewed patients needed at least 5 days of outpatient prophylaxis.Outpatient thrombosis prophylaxis clearly makes high demands on the patients, in particular when combined with the task of administering complex forms of injections. Those involved in inpatient and outpatient provision of care should not assume that all patients carry out the necessary prophylaxis at the required level of reliability. On the contrary initial evidence shows that the non-adherence of patients during ambulatory thrombosis prophylaxis presents a genuine challenge to care providers.


Assuntos
Anticoagulantes/efeitos adversos , Artroplastia de Quadril , Artroplastia do Joelho , Heparina de Baixo Peso Molecular/administração & dosagem , Adesão à Medicação , Complicações Pós-Operatórias/prevenção & controle , Tromboembolia Venosa/prevenção & controle , Idoso , Assistência Ambulatorial , Quimioterapia Combinada , Feminino , Alemanha , Inquéritos Epidemiológicos , Humanos , Injeções Subcutâneas , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/reabilitação
3.
Z Orthop Ihre Grenzgeb ; 141(3): 357-61, 2003.
Artigo em Alemão | MEDLINE | ID: mdl-12822087

RESUMO

AIM: Evaluation of practicability and functional benefit with modern carbon fibre knee ankle foot orthoses in polio patients. METHODS: In a retrospective analysis, fifty-five (55) polio patients between the ages of 42 and 80 years who had been provided with a carbon fibre orthoses for a minimum of three months, were asked about their acceptance as well as changes in functional capacity and comfort. RESULTS: Clear improvements were shown in walking, sitting and automobile driving as well as comfort and dressing/undressing of the orthoses. Through the use of these new orthoses, the maximum walking distance increased significantly--at least partially due to less weight (40%). 95% of all treated patients were very satisfied or satisfied. CONCLUSION: The use of carbon fibre material in the orthotic treatment of polio patients seems to be supported by the positive results of our study.


Assuntos
Braquetes , Carbono , Poliomielite/reabilitação , Síndrome Pós-Poliomielite/reabilitação , Atividades Cotidianas/classificação , Adulto , Idoso , Idoso de 80 Anos ou mais , Braquetes/classificação , Fibra de Carbono , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Poliomielite/classificação , Síndrome Pós-Poliomielite/classificação , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA