Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 30(Pt 2): 468-478, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36891861

RESUMO

MAXPEEM, a dedicated photoemission electron microscopy beamline at MAX IV Laboratory, houses a state-of-the-art aberration-corrected spectroscopic photoemission and low-energy electron microscope (AC-SPELEEM). This powerful instrument offers a wide range of complementary techniques providing structural, chemical and magnetic sensitivities with a single-digit nanometre spatial resolution. The beamline can deliver a high photon flux of ≥1015 photons s-1 (0.1% bandwidth)-1 in the range 30-1200 eV with full control of the polarization from an elliptically polarized undulator. The microscope has several features which make it unique from similar instruments. The X-rays from the synchrotron pass through the first beam separator and impinge the surface at normal incidence. The microscope is equipped with an energy analyzer and an aberration corrector which improves both the resolution and the transmission compared with standard microscopes. A new fiber-coupled CMOS camera features an improved modulation transfer function, dynamic range and signal-to-noise ratio compared with the traditional MCP-CCD detection system.

3.
ACS Appl Mater Interfaces ; 11(32): 29448-29457, 2019 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-31328499

RESUMO

We performed spatially resolved near-ambient-pressure photoemission spectromicroscopy on graphene-coated copper in operando under oxidation conditions in an oxygen atmosphere (0.1 mbar). We investigated regions with bare copper and areas covered with mono- and bi-layer graphene flakes, in isobaric and isothermal experiments. The key method in this work is the combination of spatial and chemical resolution of the scanning photoemission microscope operating in a near-ambient-pressure environment, thus allowing us to overcome both the material and pressure gap typical of standard ultrahigh-vacuum X-ray photoelectron spectroscopy (XPS) and to observe in operando the protection mechanism of graphene toward copper oxidation. The ability to perform spatially resolved XPS and imaging at high pressure allows for the first time a unique characterization of the oxidation phenomenon by means of photoelectron spectromicroscopy, pushing the limits of this technique from fundamental studies to real materials under working conditions. Although bare Cu oxidizes naturally at room temperature, our results demonstrate that such a graphene coating acts as an effective barrier to prevent copper oxidation at high temperatures (over 300 °C), until oxygen intercalation beneath graphene starts from boundaries and defects. We also show that bilayer flakes can protect at even higher temperatures. The protected metallic substrate, therefore, does not suffer corrosion, preserving its metallic characteristic, making this coating appealing for any application in an aggressive atmospheric environment at high temperatures.

4.
Beilstein J Nanotechnol ; 8: 1723-1733, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28904833

RESUMO

The surface chemistry of plasma fluorinated vertically aligned carbon nanotubes (vCNT) is correlated to the CF4 plasma chemical composition. The results obtained via FTIR and mass spectrometry are combined with the XPS and Raman analysis of the sample surface showing the dependence on different plasma parameters (power, time and distance from the plasma region) on the resulting fluorination. Photoemission and absorption spectroscopies are used to investigate the evolution of the electronic properties as a function of the fluorine content at the vCNT surface. The samples suffer a limited ageing effect, with a small loss of fluorine functionalities after two weeks in ambient conditions.

5.
Sci Rep ; 7(1): 7960, 2017 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-28801640

RESUMO

Carbon nanomaterials' reactivity towards oxygen is very poor, limiting their potential applications. However, nitrogen doping is an established way to introduce active sites that facilitate interaction with gases. This boosts the materials' reactivity for bio-/gas sensing and enhances their catalytic performance for the oxygen reduction reaction. Despite this interest, the role of differently bonded nitrogen dopants in the interaction with oxygen is obscured by experimental challenges and has so far resisted clear conclusions. We study the interaction of molecular oxygen with graphene doped via nitrogen plasma by in situ high-resolution synchrotron techniques, supported by density functional theory core level simulations. The interaction leads to oxygen dissociation and the formation of carbon-oxygen single bonds on graphene, along with a band gap opening and a rounding of the Dirac cone. The change of the N 1 s core level signal indicates that graphitic nitrogen is involved in the observed mechanism: the adsorbed oxygen molecule is dissociated and the two O atoms chemisorb with epoxy bonds to the nearest carbon neighbours of the graphitic nitrogen. Our findings help resolve existing controversies and offer compelling new evidence of the ORR pathway.

6.
Sci Rep ; 6: 35130, 2016 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-27721503

RESUMO

The chemical modification of multiwalled carbon nanotubes (MWCNTs) with a long chain mercapto acid is reported as a way to improve sensitivity and response time of gas sensors for detecting alcohols, acetone and toxic gases such as DMMP. We have developed sensors employing MWCNTs decorated with gold nanoparticles and modified with a 16-mercaptohexadecanoic acid (MHDA) monolayer. Morphological and compositional analysis by Transmission Electron Microscopy (TEM), Fourier Transform Infra-red Spectroscopy (FTIR) and X-ray photoelectron spectroscopy were performed to characterize the gold nanoparticles and to check the bonding of the thiol monolayer. The detection of aromatic and non-aromatic volatiles and DMMP vapors by MWCNT/Au and MWCNT/Au/MHDA shows that the presence of the self-assembled layer increases sensitivity and selectivity towards non-aromatics. Furthermore, it ameliorates response dynamics, and significantly reduces nitrogen dioxide and moisture cross-sensitivity.

7.
Beilstein J Nanotechnol ; 6: 2263-71, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26734518

RESUMO

Grafting of fluorine species on carbon nanostructures has attracted interest due to the effective modification of physical and chemical properties of the starting materials. Various techniques have been employed to achieve a controlled fluorination yield; however, the effect of contaminants is rarely discussed, although they are often present. In the present work, the fluorination of vertically aligned multiwalled carbon nanotubes was performed using plasma treatment in a magnetron sputtering chamber with fluorine diluted in an argon atmosphere with an Ar/F2 ratio of 95:5. The effect of heavily diluted fluorine in the precursor gas mixture is investigated by evaluating the modifications in the nanotube structure and the electronic properties upon plasma treatment. The existence of oxygen-based grafted species is associated with background oxygen species present in the plasma chamber in addition to fluorine. The thermal stability and desorption process of the fluorine species grafted on the carbon nanotubes during the fluorine plasma treatment were evaluated by combining different spectroscopic techniques.

8.
Langmuir ; 29(33): 10440-7, 2013 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-23879612

RESUMO

The adsorption of metal-phthalocyanine (MPc) layers (M = Fe, Co, Cu) assembled on graphene/Ir(111) is studied by means of temperature-programmed X-ray photoemission spectroscopy (XPS) and near-edge X-ray absorption fine structure (NEXAFS). The balance between interaction forces among the organometallic molecules and the underlying graphene gives rise to flat-lying molecular layers, weakly interacting with the underlying graphene. Further MPc layers pile up face-on onto the first layer, up to a few nanometers thickness, as deduced by NEXAFS. The FePc, CoPc, and CuPc multilayers present comparable desorption temperatures, compatible with molecule-molecule interactions dominated by van der Waals forces between the π-conjugated macrocycles. The MPc single layers desorb from graphene/Ir at higher temperatures. The CuPc single layer desorbs at lower temperature than the FePc and CoPc single layers, suggesting a higher adsorption energy of the FePc and CoPc single layers on graphene/Ir with respect to CuPc, with increasing molecule-substrate interaction in the order E(CuPc) < E(FePc) ~ E(CoPc).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA