Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sci Total Environ ; 407(3): 1206-10, 2009 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-18801557

RESUMO

A small air sampling system using standard air filter sampling technology has been used to monitor the air in aircraft. The device is a small ABS constructed cylinder 5 cm in diameter and 9 cm tall and can be operated by non technical individuals at an instant notice. It is completely self contained with a 4 AAA cell power supply, DC motor, a centrifugal fan, and accommodates standard 37 mm filters and backup pads. The monitor is totally enclosed and pre assembled in the laboratory. A 45 degrees twist of the cap switches on the motor and simultaneously opens up the intake ports and exhaust ports allowing air to pass through the filter. A reverse 45 degrees twist of the cap switches off the motor and closes all intake and exhaust ports, completely enclosing the filter. The whole monitor is returned to the laboratory by standard mail for analysis and reassembly for future use. The sampler has been tested for electromagnetic interference and has been approved for use in aircraft during all phases of flight. A set of samples taken by a BAe-146-300 crew member during two flights in the same aircraft and analyzed by GC-MS, indicated exposure to tricresyl phosphate (TCP) levels ranging from 31 to 83 nanograms/m(3) (detection limit <4.5 nanograms/m(3)). The latter elevated level was associated with the use of the auxiliary power unit (APU) in the aircraft. It was concluded that the air sampler was capable of monitoring air concentrations of TCP isomers in aircraft above 4.5 nanogram/m(3).


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados , Aeronaves/normas , Calibragem , Monitoramento Ambiental , Desenho de Equipamento , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Cromatografia Gasosa-Espectrometria de Massas/métodos , Viagem
2.
J Occup Environ Hyg ; 2(5): 277-84, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15884183

RESUMO

Theatrical fogs are commonly used in the entertainment industry to create special atmospheric effects during filming and live productions. We examined exposures to mineral oil-and glycol-based theatrical fogs to determine what fluids and effects were commonly used, to measure the size distributions of the aerosols, and to identify factors associated with personal exposure levels. In nonperformance jobs in a range of production types (television, film, live theater, and concerts),we measured airborne concentrations of inhalable aerosol,aldehydes, and polycyclic aromatic hydrocarbons, and collected observations about the sites and tasks performed. Both mineral oil and glycols were observed in use on about one-half the production days in the study. The most common effect produced was a generalized haze over the entire set. Mean personal inhalable aerosol concentrations were 0.70 mg/m3(range 0.02 to 4.1). The mean proportion of total aerosol mass less than 3.5 microns in aerodynamic diameter was 61%. Exposures were higher when mineral oils, rather than glycols, were used to generate fogs. Higher exposures were also associated with movie and television productions, with using more than one fog machine, with increased time spent in visible fog, and for those employed as "grips." Decreased exposures were associated with increasing room temperature, with increasing distance from fog machines, and for those employed as "sound technicians." Exposures to theatrical fogs are just beginning to be measured. It is important to consider these exposures in light of any health effects observed, since existing occupational exposure limits were developed in other industries where the aerosol composition differs from that of theatrical fogs.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Exposição Ambiental , Exposição por Inalação , Filmes Cinematográficos , Televisão , Aerossóis , Movimentos do Ar , Glicóis , Humanos , Óleo Mineral , Ocupações
3.
Am J Ind Med ; 47(5): 411-8, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15828073

RESUMO

BACKGROUND: Theatrical fogs (glycol or mineral oil aerosols) are widely used in the entertainment industry to create special effects and make lighting visible. METHODS: We studied 101 employees at 19 sites using fogs and measured personal fog exposures, across work shift lung function, and acute and chronic symptoms. Results were also compared to an external control population, studied previously. RESULTS: Chronic work-related wheezing and chest tightness were significantly associated with increased cumulative exposure to fogs (mineral oil and glycols) over the previous 2 years. Acute cough and dry throat were associated with acute exposure to glycol-based fogs; increased acute upper airway symptoms were associated with increased fog aerosol overall. Lung function was significantly lower among those working closest to the fog source. CONCLUSIONS: Mineral oil- and glycol-based fogs are associated with acute and chronic adverse effects on respiratory health among employees. Reducing exposure, through controls, substitution, and elimination where possible, is likely to reduce these effects.


Assuntos
Aerossóis/toxicidade , Poluição do Ar em Ambientes Fechados/efeitos adversos , Glicóis/toxicidade , Óleo Mineral/toxicidade , Filmes Cinematográficos , Exposição Ocupacional/efeitos adversos , Transtornos Respiratórios/induzido quimicamente , Fumaça/efeitos adversos , Televisão , Adulto , Feminino , Volume Expiratório Forçado , Humanos , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional/análise , Prevalência , Transtornos Respiratórios/epidemiologia , Fumaça/análise , Inquéritos e Questionários , Capacidade Pulmonar Total , Reino Unido/epidemiologia , Local de Trabalho
4.
Ann Occup Hyg ; 48(6): 547-54, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15302620

RESUMO

Exposure to airborne fungal products may be associated with health effects ranging from non-specific irritation of the respiratory tract or mucus membranes to inflammation provoked by specific fungal antigens. While concentrations of airborne fungi are frequently measured in indoor air quality investigations, the significance of these measurements in the absence of visual mold colonization is unclear. This study was undertaken to evaluate concentrations of airborne fungal concentrations in school classrooms within a defined geographic location in British Columbia, Canada, and to build a model to clarify determinants of airborne fungal concentration. All elementary schools within one school district participated in the study. Classrooms examined varied by age, construction and presence or absence of mechanical ventilation. Airborne fungal propagules were collected inside classrooms and outdoors. Variables describing characteristics of the environment, buildings and occupants were measured and used to construct a predictive model of fungal concentration. The classrooms studied were not visibly contaminated by fungal growth. The data were evaluated using available guidelines. However, the published guidelines did not take into account significant aspects of the local environment. For example, there was a statistically significant effect of season on the fungal concentrations and on the proportional representation of fungal genera. Rooms ventilated by mechanical means had significantly lower geometric mean concentrations than naturally ventilated rooms. Environmental (temperature, outdoor fungal concentration), building (age) and ventilation variables accounted for 58% of the variation in the measured fungal concentrations. A methodology is proposed for the evaluation of airborne fungal concentration data which takes into account local environmental conditions as an aid in the evaluation of fungal bioaerosols in public buildings.


Assuntos
Microbiologia do Ar , Poluição do Ar , Monitoramento Ambiental/métodos , Fungos/isolamento & purificação , Instituições Acadêmicas , Meio Ambiente , Modelos Biológicos , Estações do Ano , Síndrome do Edifício Doente/imunologia , Síndrome do Edifício Doente/microbiologia , Ventilação
5.
Arch Neurol ; 61(7): 1057-60, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15262735

RESUMO

BACKGROUND: The spatial and temporal pattern of excessive disease occurrence, termed clustering, may provide clues about the underlying etiology. OBJECTIVE: To report the occurrence of 3 clusters of Parkinson disease (PD) in Canada. DESIGN AND PATIENTS: We determined the population groups containing the clusters, geographical limits, and duration of exposure to the specific environments. We tested whether there was an excessive presence of Parkinson disease by calculating the probability of the observed cases occurring under the null hypothesis that the disease developed independently and at random in cluster subjects. Results of genetic testing for mutations in the alpha-synuclein, parkin, tau genes, and spinocerebellar ataxia genes (SCA2 and SCA3) were negative. RESULTS: The probabilities of random occurrence (P values) in the 3 clusters were P = 7.9 x 10 (-7)for cluster 1, P = 2.6 x 10 (-7)for cluster 2, and P = 1.5 x 10 (-7)for cluster 3. CONCLUSIONS: Our findings indicate an important role for environmental causation in Parkinson disease. A possible role exists for environmental factors such as viral infection and toxins in the light of current evidence.


Assuntos
Meio Ambiente , Doença de Parkinson/epidemiologia , Adulto , Idoso , Análise por Conglomerados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mutação , Doença de Parkinson/etiologia , Doença de Parkinson/genética
6.
J Occup Environ Hyg ; 1(10): 639-47, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15631055

RESUMO

A survey of 39 elementary schools was undertaken to determine indoor air concentrations of bioaerosols within a coastal, temperate climatic zone in British Columbia, Canada. This article reports the results for airborne bacteria. Determinants of exposure were grouped into environmental (outdoor temperature, relative humidity, season, weather), ventilation and comfort parameter (indoor relative humidity, temperature, indoor CO2 concentration, indoor fungal concentration), and occupancy (number of occupants, activity levels, occupancy patterns) variables. Regression modeling was used to evaluate the association between these factors and measured concentrations of indoor mesophilic bacteria. Naturally ventilated rooms (47% of the total rooms surveyed) had higher bacterial counts than mechanically ventilated rooms (geometric mean 325 vs. 166 CFU/m3, respectively, p < 0.001). In univariate analyses, bacterial counts were negatively correlated with supply and exhaust flow rates, air exchange rates, and the percentage of the day that occupants spent quietly sitting at their desks. Analysis of bacterial groups indicated various sources of the bacterial aerosol, with micrococci and staphylococci closely associated with occupancy variables, Bacillus with site and occupancy, and coryneform bacteria with site variables only. Approximately 60% of the variance in the outcome measurement of total bacteria was accountedfor by indoor CO2, lower air exchange rate, the age of the building, signs of current or old moisture stains, room volume, indoor relative humidity, and occupant activity level in a multiple linear regression model, with ventilation factors accounting for 40% of the variance.


Assuntos
Aerossóis/análise , Poluição do Ar em Ambientes Fechados/análise , Bactérias/isolamento & purificação , Exposição Ambiental , Colúmbia Britânica , Criança , Monitoramento Ambiental , Humanos , Análise de Regressão , Instituições Acadêmicas , Ventilação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA