Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Knee Surg Sports Traumatol Arthrosc ; 25(1): 299-305, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25743042

RESUMO

PURPOSE: Intraoperative fracture of the lateral cortex fractures of the tibia is a potential complication of high tibial osteotomy (HTO), which may result in inadequate rotational alignment of the distal tibia. Our aim was to determine how rotational malalignment of the distal tibial segment distal would affect intraarticular contact pressure distribution in the knee and ankle joints. METHODS: A medial, L-shaped opening-wedge HTO was performed on seven human lower body specimens. A stainless steel device with integrated load cell was used to axially load the leg. Pressure-sensitive sensors were used to measure intraarticular contact pressures. Intraoperative changes in alignment were monitored in real time using computer navigation. Measurements were performed in the native knee alignment, after 10° and 15° of alignment correction and with the distal tibia fixed at 15° of external rotation. RESULTS: Moderate-to-large alignment changes after medial opening-wedge HTO resulted in a shift in intraarticular contact pressures from the medial compartment of the knee towards the lateral compartment. However, fixation of the distal tibial segment at 15° of external rotation neutralized this intended beneficial effect. In the ankle, external rotation of the distal tibia also caused a reduction in contact pressures and tibiotalar contact area. CONCLUSION: Malrotation of the distal tibial fragment negates the intended effect of offloading the diseased compartment of the knee, with the contact pressures remaining similar to those of the native knee. Furthermore, malrotation leads to abnormal ankle contact pressures. Care should be taken to ensure appropriate rotational alignment of the distal tibial segment during intraoperative fixation of HTO procedures.


Assuntos
Articulação do Tornozelo/fisiopatologia , Articulação do Joelho/fisiopatologia , Osteotomia/métodos , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/cirurgia , Pressão , Rotação , Tíbia/cirurgia , Adulto , Idoso , Cadáver , Humanos , Articulação do Joelho/cirurgia , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia
2.
J Orthop Res ; 33(4): 598-604, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25418964

RESUMO

High tibial osteotomy (HTO) is a commonly used surgical technique for treating moderate osteoarthritis (OA) of the medial compartment of the knee by shifting the center of force towards the lateral compartment. Previous studies have documented the effects of HTO on the biomechanics of the knee. However, the effects of the procedure on the contact pressures within the ankle joint have not been as well described. Seven cadavers underwent an HTO procedure with sequential 5° valgus realignment of the leg up to 15° of correction. An axial force of up to 550 N was applied and the intraarticular pressure was recorded. Minor valgus realignment of the proximal tibia does not significantly alter the biomechanics of the ankle. However, moderate-to-large changes in proximal tibial alignment result in significantly decreased tibiotalar contact surface area and in changes in intraarticular ankle pressures. These findings are clinically relevant, as they provide a biomechanical rationale for the diagnosis and treatment of ankle symptoms in the setting of lower limb malalignment or after alignment correction procedures.


Assuntos
Articulação do Tornozelo/fisiopatologia , Articulação do Joelho/fisiopatologia , Osteoartrite/fisiopatologia , Osteoartrite/cirurgia , Osteotomia , Suporte de Carga , Fenômenos Biomecânicos , Cadáver , Humanos , Pressão , Análise de Regressão
3.
Int J Med Robot ; 11(1): 30-7, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24941911

RESUMO

BACKGROUND: For the further development of robot-assisted endoscope guidance in functional endoscopic sinus surgery (FESS), ground data about the workspaces and endoscope movements in conventional FESS are needed. METHODS: Applying a self-developed marker-based tracking system, we collected the pose data (position and orientation) of the endoscope and all other instruments used in five real sinus surgeries. RESULTS: The automated segmentation of the endoscope poses shows the shape of a hourglass, with a pivot region or pivot point at the 'waistline' of the hourglass, close to the nasal entrance in the nasal dome. CONCLUSION: We were able to identify a pivot point at the waistline of the segmented endoscope poses. The size of the pivot point corresponds with the diameter of the 4 mm endoscope. Because of the reduction to four degrees of freedom for endoscope motions (three rotations and one translation), easier and safer robot-assisted endoscope guidance becomes feasible.


Assuntos
Endoscopia/métodos , Seios Paranasais/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Endoscópios , Estudos de Viabilidade , Humanos , Seios Paranasais/patologia , Procedimentos Cirúrgicos Robóticos/instrumentação , Cirurgia Assistida por Computador/métodos
4.
Comput Methods Programs Biomed ; 106(2): 104-13, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22306073

RESUMO

Articulated structures like the human body have many degrees of freedom. This makes an evaluation of the configuration's likelihood very challenging. In this work we propose new linked hierarchical graphical models which are able to efficiently evaluate likelihoods of articulated structures by sharing visual primitives. Instead of evaluating all configurations of the human body separately we take advantage of the fact that different configurations of the human body share body parts, and body parts, in turn, share visual primitives. A hierarchical Markov random field is used to integrate the sharing of visual primitives in a probabilistic framework. We propose a scalable hierarchical representation of the human body and show that this representation is especially well suited for human gait analysis from a frontal camera perspective. Furthermore, the results of the evaluation on a gait dataset show that sharing primitives substantially accelerates the evaluation and that our hierarchical probabilistic framework is a robust method for scalable detection of the human body.


Assuntos
Marcha , Gráficos por Computador , Sistemas de Gerenciamento de Base de Dados , Humanos , Funções Verossimilhança , Curva ROC
5.
Eur Arch Otorhinolaryngol ; 265(9): 1061-70, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18253744

RESUMO

Manual segmentation is often used for evaluation of automatic or semi-automatic segmentation. The purpose of this paper is to describe the inter and intraindividual variability, the dubiety of manual segmentation as a gold standard and to find reasons for the discrepancy. We realized two experiments. In the first one ten ENT surgeons, ten medical students and one engineer outlined the right maxillary sinus and ethmoid sinuses manually on a standard CT dataset of a human head. In the second experiment two participants outlined maxillary sinus and ethmoid sinuses five times consecutively. Manual segmentation was accomplished with custom software using a line segmentation tool. The first experiment shows the interindividual variability of manual segmentation which is higher for ethmoidal sinuses than for maxillary sinuses. The variability can be caused by the level of experience, different interpretation of the CT data or different levels of accuracy. The second experiment shows intraindividual variability which is lower than interindividual variability. Most variances in both experiments appear during segmentation of ethmoidal sinuses and outlining hiatus semilunaris. Concerning the inter and intraindividual variances the segmentation result of one manual segmenter could not directly be used as gold standard for the evaluation of automatic segmentation algorithms.


Assuntos
Seios Paranasais/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Adulto , Feminino , Humanos , Imageamento Tridimensional , Masculino , Reprodutibilidade dos Testes , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA