Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Nucl Med Technol ; 43(4): 275-81, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26584615

RESUMO

UNLABELLED: The objective of this study was to determine the relative utility of 3 state-of-the-art parathyroid imaging protocols: single-time-point simultaneous acquisition of (99m)Tc-sestamibi and (123)I images with pinhole collimation in the anterior and bilateral anterior oblique projections, single-time-point simultaneous acquisition of (99m)Tc-sestamibi and (123)I images with SPECT/CT, and the combination of the first and second protocols. METHODS: Fifty-nine patients with surgical proof of parathyroid adenomas were evaluated retrospectively. All 3 protocols included perfectly coregistered subtraction images created by subtracting the (123)I images from the (99m)Tc-sestamibi images, plus an anterior parallel-hole collimator image of the neck and upper chest. The pinhole protocol was performed first, followed by the SPECT/CT protocol. Three image sets were derived from each study in each patient according to the above protocols. Two experienced observers recorded the size, location, and degree of certainty of any identified lesion. RESULTS: The 59 patients had 61 adenomas. For the 2 observers combined, the localization success rate was 88% for the pinhole protocol, 69% for the SPECT/CT protocol, and 81% for the combined protocol. The pinhole protocol detected more adenomas than the SPECT/CT protocol and missed fewer adenomas than either the SPECT/CT protocol or the combined pinhole and SPECT/CT protocol (P < 0.01). The 2 protocols that included SPECT/CT provided superior anatomic information relative to the location and size of the parathyroid adenomas. CONCLUSION: The pinhole protocol localized significantly more adenomas than the SPECT/CT protocol. However, the protocols that included SPECT/CT provided more anatomic information than pinhole imaging alone.


Assuntos
Radioisótopos do Iodo , Imagem Multimodal/métodos , Glândulas Paratireoides/diagnóstico por imagem , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Cartilagem Cricoide/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA