Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 2451-2454, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086454

RESUMO

Reducing the power consumption of wearable sensors is a very important issue in relation to the device usage time and form factor. However, continuous wireless communication to analyze the measured signal in real-time significantly increases the power consumption of the wearable sensor. In this study, we propose a wearable vibration sensor that operates with extremely low power through an embedded signal classifier, which exhibits high accuracy and low calculation load. We demonstrate cough detection through the proposed sensor system. The result exhibits an accuracy of 93.0%, which is 24.3% higher than the conventional embedded classification algorithm. Also, the proposed approach reduces the average power consumption of the wearable sensor by 8.8 times. Clinical Relevance-People can measure the vibration from the body using an ultra-low-power wearable sensor. It provides a solution to automatically monitor cough symptoms in numerous patients.


Assuntos
Vibração , Dispositivos Eletrônicos Vestíveis , Algoritmos , Tosse/diagnóstico , Humanos , Monitorização Fisiológica
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 7340-7343, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34892793

RESUMO

Vocal cord disorder is one of the important health problems, especially in noisy industrial sites where excessive voice is required. A convenient and reliable communication method is required in a noisy environment to prevent the related disorders. However, the signal sensitivity of previous neck microphones is still insufficient to accurately convey the voice. In this study, we developed a skin-attachable neck microphone with a lightweight and flexible form factor. Also, we optimized the attachment position and covering pressure to maximize the signal sensitivity. As a result, we obtained the optimal position near the thyroid cartilage and confirmed that the signal sensitivity is the highest when the covering pressure is approximately 4 mmHg.Clinical Relevance- People can measure the voice status using a wearable neck microphone at the optimal position and covering pressure. It provides a solution to keep the vocal cords in good health even in a noisy environment.


Assuntos
Voz , Dispositivos Eletrônicos Vestíveis , Humanos , Pescoço , Pele
3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 4134-4137, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-33018908

RESUMO

In recent years, surface electromyography (sEMG) has been commonly used to diagnose neuromuscular abnormalities. Since sEMG measures electrical signals from various tangled muscle nerves, a high signal-to-noise ratio (SNR) is required to estimate the condition accurately. Previously, Ag/AgCl electrodes were widely used for sEMG measurements, but noble metals are more advantageous for long-term and continuous measurement. In this study, we improved the SNR of bioelectrical signals by increasing the surface area of a flexible skin-electrode made of noble metal. The electrode surface area was increased by 1.38 times with electroplating, and the SNR of sEMG was improved by 1.63 times. Utilizing the sEMG signals with high SNR, we propose a new muscle fatigue estimation algorithm for monitoring the muscle condition in real-time.


Assuntos
Algoritmos , Fadiga Muscular , Eletrodos , Eletromiografia , Razão Sinal-Ruído
4.
Sensors (Basel) ; 20(1)2019 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-31861930

RESUMO

Numerous wearable sensors have been developed for a variety of needs in medical/healthcare/wellness/sports applications, but there are still doubts about their usefulness due to uncomfortable fit or frequent battery charging. Because the size or capacity of battery is the major factor affecting the convenience of wearable sensors, power consumption must be reduced. We developed a method that can significantly reduce the power consumption by introducing a signal repeater and a special switch that provides power only when needed. Antenna radiation characteristics are an important factor in wireless wearable sensors, but soft material encapsulation for comfortable fit results in poor wireless performance. We improved the antenna radiation characteristics by a local encapsulation patterning. In particular, ultra-low power operation enables the use of paper battery to achieve a very thin and flexible form factor. Also, we verified the human body safety through specific absorption rate simulations. With these methods, we demonstrated a wearable infant sleep position sensor. Infants are unable to call for help in unsafe situations, and it is not easy for caregivers to observe them all the time. Our wearable sensor detects infants' sleep positions in real time and automatically alerts the caregivers when needed.

5.
J Org Chem ; 84(24): 16293-16298, 2019 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-31778067

RESUMO

We report the dynamic kinetic resolution (DKR) of various secondary alcohols by the combination of a ruthenium catalyst and an anionic surfactant-activated lipoprotein lipase. The DKR reactions performed under totally base-free conditions at room temperature provided the products of excellent enantiopurities (91-99% ee or greater) in high yields (92-99%). More importantly, the DKR of α-arylallyl alcohols was achieved for the first time with high yields (87-91%).

6.
Nat Commun ; 10(1): 2468, 2019 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-31213598

RESUMO

Flexible and skin-attachable vibration sensors have been studied for use as wearable voice-recognition electronics. However, the development of vibration sensors to recognize the human voice accurately with a flat frequency response, a high sensitivity, and a flexible/conformable form factor has proved a major challenge. Here, we present an ultrathin, conformable, and vibration-responsive electronic skin that detects skin acceleration, which is highly and linearly correlated with voice pressure. This device consists of a crosslinked ultrathin polymer film and a hole-patterned diaphragm structure, and senses voices quantitatively with an outstanding sensitivity of 5.5 V Pa-1 over the voice frequency range. Moreover, this ultrathin device (<5 µm) exhibits superior skin conformity, which enables exact voice recognition because it eliminates vibrational distortion on rough and curved skin surfaces. Our device is suitable for several promising voice-recognition applications, such as security authentication, remote control systems and vocal healthcare.


Assuntos
Vibração , Voz , Dispositivos Eletrônicos Vestíveis , Desenho de Equipamento , Humanos , Pescoço , Polímeros , Pressão , Pele
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA