1.
Int J Cardiol ; 301: 114-118, 2020 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-31753583

RESUMO

BACKGROUND: According to guidelines, implantable cardioverter defibrillator (ICD) candidates must have a "reasonable expectation of survival with a good functional status >1 year". Identifying risk for early mortality in ICD candidates could be challenging. We aimed to identify factors associated with a ≤1-year survival among patients implanted with ICDs. METHODS: The DAI-PP program was a multicenter, observational French study that included all patients who received a primary prevention ICD in the 2002-2012 period. Characteristics of patients who survived ≤1 year following the implantation were compared with those who survived >1 year, and predictors of early death determined. RESULTS: Out of the 5539 enrolled patients, survival status at 1 year was known for a total of 5,457, and overall 230 (4.2%) survived ≤1 year. Causes of death were similar in the two groups. Patients with ≤1-year survival had lower rates of appropriate (14 vs. 23%; P = 0.004) and inappropriate ICD therapies (2 vs. 7%; P = 0.009) than patients who lived >1 year after ICD implantation. In multivariate analysis, older age, higher NYHA class (≥III), and atrial fibrillation were significantly associated with ≤1-year survival. Presence of all 3 risk factors was associated with a cumulative 22.63% risk of death within 1 year after implantation. CONCLUSIONS: This is the largest study determining the factors predicting early mortality after ICD implantation. Patients dying within the first year had low ICD therapy rates. A combination of clinical factors could potentially identify patients at risk for early mortality to help improve selection of ICD candidates.

2.
Arch Cardiovasc Dis ; 112(8-9): 523-531, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31471226

RESUMO

This review summarizes the main findings of the French multicentre DAI-PP pilot programme, and discusses the related clinical and research perspectives. This project included retrospectively (2002-2012 period) more than 5000 subjects with structural heart disease who received an implantable cardioverter defibrillator (ICD) for primary prevention of sudden cardiac death, and were followed for a mean period of 3 years. The pilot phase of the DAI-PP programme has provided valuable information on several practical and clinically relevant aspects of primary prevention ICD implantation in the real-world population, which are summarized in this review. This pilot has led to a prospective evaluation that started in May 2018, assessing ICD therapy in primary and secondary prevention in patients with structural and electrical heart diseases, with remote monitoring follow-up using a dedicated platform. This should further enhance our understanding of sudden cardiac death, to eventually optimize the field of preventative actions.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Prevenção Primária/métodos , Morte Súbita Cardíaca/epidemiologia , França/epidemiologia , Humanos , Estudos Multicêntricos como Assunto , Projetos Piloto , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
J Arrhythm ; 35(2): 238-243, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31007788

RESUMO

Background: Combination of elementary parameters (force, time, power, impedance drop) has been proposed to optimize radiofrequency (RF) delivery. They have been partially validated in clinical studies. Aims: The aim of this study was to assess contact-force (CF) implementation into clinical practice. Methods: A 36-question electronic form was sent to 105 electrophysiologists (EP) including some general questions concerning the practice of catheter atrial fibrillation ablation and items concerning the parameters used for CF-guided ablation. Results: Answers from 98 EP were collected (93% response rate). The CF-catheters used were Smart Touch, Biosense (52%), Tacticath, Saint-Jude Medical (12%), or both (27%) and no CF (9%). The power applied on the left atrial (LA) anterior (LAAW) and posterior (LAPW) wall was, respectively, 26-34 W (for 73% of the EP) and below 25 W (88% of the EP). Forty percent of the Visitag® users mostly used the nominal parameters. Seventy-five percent of the users did not use automatic display of the impedance drop. For the Tacticath users, 57% used a target value of 400 gs on the LAAW and 300 to 400 gs on the LAPW. Lesion Size Index was exceptionally used. Conclusions: The parameters used for CF-guided ablation are widely variable among the different operators. Further prospective studies are needed to validate the targets for automatic annotation of the RF applications.

5.
Ecol Evol ; 9(7): 4168-4180, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31015996

RESUMO

Climate change threatens coastal benthic communities on a global scale. However, the potential effects of ongoing warming on mesophotic temperate reefs at the community level remain poorly understood. Investigating how different members of these communities will respond to the future expected environmental conditions is, therefore, key to anticipating their future trajectories and developing specific management and conservation strategies. Here, we examined the responses of some of the main components of the highly diverse Mediterranean coralligenous assemblages to thermal stress. We performed thermotolerance experiments with different temperature treatments (from 26 to 29°C) with 10 species from different phyla (three anthozoans, six sponges and one ascidian) and different structural roles. Overall, we observed species-specific contrasting responses to warming regardless of phyla or growth form. Moreover, the responses ranged from highly resistant species to sensitive species and were mostly in agreement with previous field observations from mass mortality events (MMEs) linked to Mediterranean marine heat waves. Our results unravel the diversity of responses to warming in coralligenous outcrops and suggest the presence of potential winners and losers in the face of climate change. Finally, this study highlights the importance of accounting for species-specific vulnerabilities and response diversity when forecasting the future trajectories of temperate benthic communities in a warming ocean.

6.
Europace ; 21(7): 1063-1069, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30891608

RESUMO

AIMS: Current guidelines do not propose any age cut-off for the primary prevention implantable cardioverter-defibrillator (ICD). However, the risk/benefit balance in the very elderly population has not been well studied. METHODS AND RESULTS: In a multicentre French study assessing patients implanted with an ICD for primary prevention, outcomes among patients aged ≥80 years were compared with <80 years old controls matched for sex and underlying heart disease (ischaemic and dilated cardiomyopathy). A total of 300 ICD recipients were enrolled in this specific analysis, including 150 patients ≥80 years (mean age 81.9 ± 2.0 years; 86.7% males) and 150 controls (mean age 61.8 ± 10.8 years). Among older patients, 92 (75.6%) had no more than one associated comorbidity. Most subjects in the elderly group got an ICD as part of a cardiac resynchronization therapy procedure (74% vs. 46%, P < 0.0001). After a mean follow-up of 3.0 ± 2 years, 53 patients (35%) in the elderly group died, including 38.2% from non cardiovascular causes of death. Similar proportion of patients received ≥1 appropriate therapy (19.4% vs. 21.6%; P = 0.65) in the elderly group and controls, respectively. There was a trend towards more early perioperative events (P = 0.10) in the elderly, with no significant increase in late complications (P = 0.73). CONCLUSION: Primary prevention ICD recipients ≥80 years in the real world had relatively low associated comorbidity. Rates of appropriate therapies and device-related complications were similar, compared with younger subjects. Nevertheless, the inherent limitations in interpreting observational data on this particular competing risk situation call for randomized controlled trials to provide definitive answers. Meanwhile, a careful multidisciplinary evaluation is needed to guide patient selection for ICD implantation in the elderly population.

8.
Arch Cardiovasc Dis ; 112(1): 67-73, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30166064

RESUMO

The introduction of catheter ablation techniques has vastly improved the treatment of cardiac arrhythmias. However, as complex ablations are technically demanding and can cause various complications, they require a high level of expertise to maximize success rates and minimize complication rates. As French recommendations regarding the required technical competence and equipment are not yet available, this position paper has been compiled by the Working Group of Pacing and Electrophysiology of the French Society of Cardiology, detailing the required features of an interventional cardiac electrophysiological centre for complex ablation procedures: (1) sufficient institutional volume; (2) physician training, qualifications and experience; (3) paramedical staff training and attendance; and (4) institutional facilities and technical equipment. The importance of being able to diagnose, monitor and manage complications associated with complex ablations is highlighted. Supplemental hospital-based resources are also discussed, such as anaesthesia, surgical back-up, intensive care, haemodynamic assistance and imaging. Further, the ideal features of an interventional cardiac electrophysiology training centre are considered. Lastly, the need for quality evaluations and national registries for complex ablations is discussed.


Assuntos
Arritmias Cardíacas/cirurgia , Cardiologia/normas , Ablação por Cateter/normas , Competência Clínica/normas , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Cardiologia/educação , Ablação por Cateter/efeitos adversos , Consenso , Credenciamento/normas , Educação de Pós-Graduação em Medicina/normas , França , Humanos , Resultado do Tratamento
10.
Sci Rep ; 8(1): 17455, 2018 11 29.
Artigo em Inglês | MEDLINE | ID: mdl-30498253

RESUMO

Climate change threatens the structure and function of marine ecosystems, highlighting the importance of understanding the response of species to changing environmental conditions. However, thermal tolerance determining the vulnerability to warming of many abundant marine species is still poorly understood. In this study, we quantified in the field the effects of a temperature anomaly recorded in the Mediterranean Sea during the summer of 2015 on populations of two common sympatric bryozoans, Myriapora truncata and Pentapora fascialis. Then, we experimentally assessed their thermal tolerances in aquaria as well as different sublethal responses to warming. Differences between species were found in survival patterns in natural populations, P. fascialis showing significantly lower survival rates than M. truncata. The thermotolerance experiments supported field observations: P. fascialis started to show signs of necrosis when the temperature was raised to 25-26 °C and completely died between 28-29 °C, coinciding with the temperature when we observed first signs of necrosis in M. truncata. The results from this study reflect different responses to warming between these two co-occurring species, highlighting the importance of combining multiple approaches to assess the vulnerability of benthic species in a changing climate world.


Assuntos
Briozoários/genética , Mudança Climática , Ecossistema , Aquecimento Global , Animais , Briozoários/ultraestrutura , Mar Mediterrâneo , Estações do Ano , Estresse Fisiológico , Temperatura Ambiente
11.
Arch Cardiovasc Dis ; 111(12): 758-765, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30078651

RESUMO

BACKGROUND: The frequency, characteristics and outcomes of primary prevention implantable cardioverter defibrillator (ICD) recipients who eventually undergo heart transplantation (HT) during follow-up have not been well described. AIMS: In a cohort of patients with heart failure implanted with an ICD for primary prevention of sudden cardiac death, to identify those at high risk of subsequent HT and evaluate ICD usefulness. METHODS: Between 2002 and 2012, 5539 patients received a primary prevention ICD across 12 centers, and were enrolled in the DAI-PP programme, including 5427 with full HT information available. RESULTS: During a median follow-up of 1024 days (interquartile range 484-1702 days), 176 (3.2%) patients underwent HT. Median duration between ICD implantation and HT was 484 days (IQR 169-1117 days). Among those aged≤65 years (theoretical age limit for HT registration in France), the overall incidence per 1000 person-years was 18.03 (95% confidence interval [CI]: 15.32-20.74). Left ventricular ejection fraction<25% (hazard ratio [HR]: 3.43, 95% CI: 2.34-5.04; P<0.0001), younger age (HR: 0.95, 95% CI: 0.93-0.96; P<0.0001), New York Heart Association (NYHA) class III-IV (HR: 2.67, 95% CI: 1.79-4.00; P<0.0001) and no cardiac resynchronization therapy (HR: 2.09, 95% CI: 1.39-3.14; P=0.0004) were independently associated with HT. Patients with these three characteristics (excluding age) had a 1-year HT rate of 15.2%. Incidence of appropriate ICD therapies was 92.7 per 1000 person-years for patients who underwent HT versus 76.1 for those who did not (P=0.64). CONCLUSIONS: The overall incidence of HT in this primary prevention population was relatively high, especially among young patients with a very low ejection fraction, an advanced NYHA class and were unsuitable for cardiac resynchronization therapy (up to 15% annually). Patients awaiting HT experienced a significant rate of appropriate ICD therapies, reinforcing the importance of specific cardiac rhythm management in these patients.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Insuficiência Cardíaca/terapia , Transplante de Coração , Prevenção Primária/instrumentação , Adulto , Idoso , Morte Súbita Cardíaca/epidemiologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , França/epidemiologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Transplante de Coração/efeitos adversos , Transplante de Coração/mortalidade , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
12.
J Am Heart Assoc ; 7(11)2018 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-29807890

RESUMO

BACKGROUND: Longer QRS duration (QRSd) improves, but increased left ventricular (LV) end-diastolic volume (LVEDV) reduces, efficacy of cardiac resynchronization therapy (CRT). QRSd/LVEDV ratios differ between sexes. We hypothesized that in the EchoCRT (Echocardiography Guided Cardiac Resynchronization Therapy) trial enrolling patients with heart failure with QRSd <130 ms, those with larger LVEDV would deteriorate but those with the highest QRSd/LVEDV would improve with CRT. METHODS AND RESULTS: Primary outcome in patients (n=787, 72% men, 93% New York Heart Association class III, QRSd <130 ms, LV ejection fraction ≤35%, LV dilation and dyssynchrony) randomized to CRT-ON or CRT-OFF and followed up for 19 months was compared according to LVEDV (height indexed) or QRSd/LVEDV ratio, in multivariable analysis. Structural remodeling was assessed echocardiographically 6 months after implantation. Patients with baseline LVEDV higher than or equal to median worsened with CRT (death/heart failure hospitalization: CRT-ON versus CRT-OFF, 35.2% versus 24.5% [hazard ratio, 1.64; 95% confidence interval, 1.11-2.42; P=0.012]), but those with LVEDV lower than median remained unaffected. Patients with the highest QRSd/LVEDV ratio improved with CRT (death/heart failure hospitalization in top quartile: 20.9% in CRT-ON [n=91] versus 28.3% in CRT-OFF [n=106] [hazard ratio, 0.64; 95% confidence interval, 0.34-1.24; P=0.188], versus the remaining quartiles: 31.7% in CRT-ON [n=300] versus 24.8% in CRT-OFF [n=290] [hazard ratio, 1.47; 95% confidence interval, 1.07-2.02; P=0.016], test for interaction P=0.046). QRSd and dyssynchrony were similar between groups. The 3-way test for interaction indicated no sex-specific effects. However, numerically, men with LVEDV higher than or equal to median accounted for worse outcomes of CRT-ON. Women, with the highest QRSd/LVEDV ratio exhibited significant reverse remodeling. CONCLUSION: CRT has opposite effects among patients with heart failure with QRSd <130 ms according to LV size: worsening outcomes in patients with larger LV, but inducing beneficial effects in those with smaller LV. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov/. Unique identifier: NCT00683696.


Assuntos
Terapia de Ressincronização Cardíaca , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Hipertrofia Ventricular Esquerda/terapia , Função Ventricular Esquerda , Remodelação Ventricular , Potenciais de Ação , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Ecocardiografia , Eletrocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Ventrículos do Coração/diagnóstico por imagem , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico , Hipertrofia Ventricular Esquerda/mortalidade , Hipertrofia Ventricular Esquerda/fisiopatologia , Masculino , Pessoa de Meia-Idade , Medição de Risco , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Resultado do Tratamento
13.
Artigo em Inglês | MEDLINE | ID: mdl-29808920

RESUMO

BACKGROUND: Steroid-eluting (SE) electrodes suppress local inflammation and lower pacing capture thresholds (PCT); however, their effectiveness on quadripolar left ventricular (LV) leads in the cardiac vein is not fully studied. We evaluated the effectiveness of SE on all four LV pacing electrodes in human subjects enrolled in the Medtronic Attain® Performa™ quadripolar LV lead study. METHODS: A total of 1,097 subjects were included in this evaluation. At each follow-up visit (1, 3, 6, and 12 months), LV PCT and pacing impedance were measured using either manual or automated testing methods. Summary statistics for PCT and impedance values were obtained for implant and each scheduled follow-up visit for all lead models. RESULTS: Average extended bipolar (LV electrode to right ventricular Coil) PCTs for the four LV SE pacing electrodes (LV1, LV2, LV3, and LV4) on the three shapes of the quadripolar LV leads were 1.06 ± 0.97 V, 1.38 ± 1.26 V, 1.51 ± 1.33 V, and 2.25 ± 1.63 V, respectively, at 0.5-ms pulse width. PCTs remained low and stable throughout the 12-month follow-up period. CONCLUSION: This clinical trial demonstrated that SE on all LV pacing electrodes is associated with low and stable PCTs for all quadripolar LV lead electrodes, resulting in multiple viable vectors for LV pacing. The large number of available vectors facilitates basal pacing, avoidance of PNS, and potentially prolongs generator longevity due to lower PCTs.

14.
J Am Coll Cardiol ; 71(14): 1528-1536, 2018 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-29622159

RESUMO

BACKGROUND: Transcatheter left atrial appendage (LAA) occlusion is an alternative strategy for stroke prevention in patients with atrial fibrillation (AF). OBJECTIVES: This study sought to determine the incidence, predictors, and prognosis of thrombus formation on devices in patients with AF who were treated with LAA closure. METHODS: The study retrospectively analyzed data from patients treated with 2 LAA closure devices seen in 8 centers in France from February 2012 to January 2017. RESULTS: A total of 469 consecutive patients with AF underwent LAA closure (272 Watchman devices [Atritech, Boston Scientific, Natick, Massachusetts] and 197 Amplatzer devices [St. Jude Medical, Minneapolis, Minnesota]). Mean follow-up was 13 ± 13 months, during which 339 (72.3%) patients underwent LAA imaging at least once. There were 98 major adverse events (26 thrombi on devices, 19 ischemic strokes, 2 transient ischemic attacks, 18 major hemorrhages, 33 deaths) recorded in 89 patients. The incidence of device-related thrombus in patients with LAA imaging was 7.2% per year. Older age (hazard ratio [HR]: 1.07 per 1-year increase; 95% confidence interval [CI]: 1.01 to 1.14; p = 0.02) and history of stroke (HR: 3.68; 95% CI: 1.17 to 11.62; p = 0.03) were predictors of thrombus formation on the devices, whereas dual antiplatelet therapy (HR: 0.10; 95% CI: 0.01 to 0.76; p = 0.03) and oral anticoagulation at discharge (HR: 0.26; 95% CI: 0.09 to 0.77; p = 0.02) were protective factors. Thrombus on the device (HR: 4.39; 95% CI: 1.05 to 18.43; p = 0.04) and vascular disease (HR: 5.03; 95% CI: 1.39 to 18.23; p = 0.01) were independent predictors of ischemic strokes and transient ischemic attacks during follow-up. CONCLUSIONS: Thrombus formation on the device is not uncommon in patients with AF who are treated by LAA closure. Such events are strongly associated with a higher risk of ischemic stroke during follow-up. (REgistry on Real-Life EXperience With Left Atrial Appendage Occlusion [RELEXAO]; NCT03279406).


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Isquemia Encefálica/prevenção & controle , Cardiopatias/etiologia , Complicações Pós-Operatórias , Dispositivo para Oclusão Septal/efeitos adversos , Trombose/etiologia , Idoso , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Isquemia Encefálica/etiologia , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Falha de Equipamento , Feminino , Seguimentos , Cardiopatias/diagnóstico , Humanos , Masculino , Estudos Retrospectivos , Trombose/diagnóstico , Tomografia Computadorizada por Raios X
15.
Int J Cardiol ; 260: 82-87, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29622458

RESUMO

BACKGROUND: Almost 1/3 of heart failure patients fail to respond to cardiac resynchronization therapy (CRT). A simple clinical score to predict who these patients are at the moment of referral or at time of implant may be of importance for early optimization of their management. METHODS: Observational study. A risk score was derived from factors associated to CRT response. The derivation cohort was composed of 1301 patients implanted with a CRT defibrillator in a multi-center French cohort-study. External validation of this score and assessment of its association with CRT response and all-cause mortality and/or heart transplant was performed in 1959 CRT patients implanted in 4 high-volume European centers. RESULTS: Independent predictors of CRT response in the derivation cohort were: female gender (OR = 2.08, 95% CI 1.26-3.45), NYHA class ≤ III (OR = 2.71, 95% CI 1.63-4.52), left ventricular ejection fraction ≥ 25% (OR = 1.75, 95% CI 1.27-2.41), QRS duration ≥ 150 ms (OR = 1.70, 95% CI 1.25-2.30) and estimated glomerular filtration rate ≥ 60 mL/min (OR = 2.01, 95% CI 1.48-2.72). Each was assigned 1 point. External validation showed good calibration (Hosmer-Lemeshow test-P = 0.95), accuracy (Brier score = 0.19) and discrimination (c-statistic = 0.67), with CRT response increasing progressively from 37.5% in patients with a score of 0 to 91.9% among those with score of 5 (Gamma for trend = 0.44, P < 0.001). Similar results were observed regarding all-cause mortality or heart transplant. CONCLUSION: The ScREEN score (Sex category, Renal function, ECG/QRS width, Ejection fraction and NYHA class) is composed of widely validated, easy to obtain predictors of CRT response, and predicts CRT response and overall mortality. It should be helpful in facilitating early consideration of alternative therapies for predicted non-responders to CRT therapy.


Assuntos
Terapia de Ressincronização Cardíaca/tendências , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Idoso , Feminino , Seguimentos , Taxa de Filtração Glomerular/fisiologia , Insuficiência Cardíaca/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Risco , Resultado do Tratamento
16.
J Am Coll Cardiol ; 71(12): 1325-1333, 2018 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-29566816

RESUMO

BACKGROUND: Cross correlation analysis (CCA) using tissue Doppler imaging has been shown to be associated with outcome after cardiac resynchronization therapy (CRT) in patients with heart failure (HF) with wide QRS. However, its significance in patients with narrow QRS treated with CRT is unknown. OBJECTIVES: The aim of the current study was to investigate the association of mechanical activation delay by CCA with study outcome in patients with HF enrolled in the EchoCRT trial. METHODS: Baseline CCA could be performed from tissue Doppler imaging in the apical views in 807 of 809 (99.7%) enrolled patients, and 6-month follow-up could be performed in 610 of 635 (96%) patients with available echocardiograms. Patients with a pre-specified maximal activation delay ≥35 ms were considered to have significant delay. The study outcome was HF hospitalization or death. RESULTS: Of 807 patients, 375 (46%) did not have delayed mechanical activation at baseline by CCA. Patients without delayed mechanical activation who were randomized to CRT-On compared with CRT-Off had an increased risk of poor outcome (hazard ratio: 1.70; 95% confidence interval: 1.13 to 2.55; p = 0.01) with a significant interaction term (p = 0.04) between delayed mechanical activation and device randomization for the endpoint. Among patients with paired baseline and follow-up data with no events before 6-month follow-up (n = 541), new-onset delayed mechanical activation in the CRT-On group showed a significant increase in unfavorable events (hazard ratio: 3.73; 95% confidence interval: 1.15 to 12.14; p = 0.03). CONCLUSIONS: In the EchoCRT population, absence of delayed mechanical activation by CCA was significantly associated with poor outcomes, possibly due to the onset of new delayed mechanical activation with CRT pacing. (Echocardiography Guided Cardiac Resynchronization Therapy [EchoCRT] Trial; NCT00683696).


Assuntos
Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/terapia , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Frequência Cardíaca/fisiologia , Adulto , Idoso , Arritmias Cardíacas/epidemiologia , Ecocardiografia Doppler/métodos , Feminino , Seguimentos , Insuficiência Cardíaca/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade
17.
Heart ; 104(18): 1529-1535, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29540431

RESUMO

OBJECTIVE: In patients indicated for cardiac resynchronisation therapy (CRT), the choice between a CRT-pacemaker (CRT-P) versus defibrillator (CRT-D) remains controversial and indications in this setting have not been well delineated. Apart from inappropriate therapies, which are inherent to the presence of a defibrillator, whether adding defibrillator to CRT in the primary prevention setting impacts risk of other acute and late device-related complications has not been well studied and may bear relevance for device selection. METHODS: Observational multicentre European cohort study of 3008 consecutive patients with ischaemic or non-ischaemic dilated cardiomyopathy and no history of sustained ventricular arrhythmias, undergoing CRT implantation with (CRT-D, n=1785) or without (CRT-P, n=1223) defibrillator. Using propensity score and competing risk analyses, we assessed the risk of significant device-related complications requiring surgical reintervention. Inappropriate shocks were not considered except those due to lead malfunction requiring lead revision. RESULTS: Acute complications occurred in 148 patients (4.9%), without significant difference between groups, even after considering potential confounders (OR=1.20, 95% CI 0.72 to 2.00, p=0.47). During a mean follow-up of 41.4±29 months, late complications occurred in 475 patients, giving an annual incidence rate of 26 (95% CI 9 to 43) and 15 (95% CI 6 to 24) per 1000 patient-years in CRT-D and CRT-P patients, respectively. CRT-D was independently associated with increased occurrence of late complications (HR=1.68, 95% CI 1.27 to 2.23, p=0.001). In particular, when compared with CRT-P, CRT-D was associated with an increased risk of device-related infection (HR 2.10, 95% CI 1.18 to 3.45, p=0.004). Acute complications did not predict overall late complications, but predicted device-related infection (HR 2.85, 95% CI 1.71 to 4.56, p<0.001). CONCLUSIONS: Compared with CRT-P, CRT-D is associated with a similar risk of periprocedural complications but increased risk of long-term complications, mainly infection. This needs to be considered in the decision of implanting CRT with or without a defibrillator.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Cardiomiopatia Dilatada/terapia , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Prevenção Primária/métodos , Taquicardia Ventricular/prevenção & controle , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Cardiomiopatia Dilatada/complicações , Feminino , Humanos , Masculino , Pontuação de Propensão , Fatores de Risco , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento
18.
Int J Cardiol ; 259: 88-93, 2018 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-29579617

RESUMO

OBJECTIVE: Cardiac resynchronisation therapy (CRT) is limited by a substantial proportion of non-responders. Left ventricular endocardial pacing (LVEP) may offer enhanced possibility to deliver CRT in patients with a failed attempt at implantation and to improve clinical status of CRT non-responders. METHODS: The ALternate Site Cardiac ResYNChronisation (ALSYNC) study was a prospective, multi-centre cohort study that included 118 CRT patients with a successfully implanted endocardial left ventricular (LV) lead, including 90 failed coronary sinus (CS) implants and 28 prior non-responders who had worsened or unchanged heart failure status after at least 6 months of optimal conventional CRT therapy. RESULTS: Patients were followed for 19 ±â€¯9 months. At baseline, prior non-responders were sicker as evidenced by a larger LV end-diastolic diameter (70 ±â€¯12 vs 65 ±â€¯9 mm, p = .03) and a trend towards larger LV end-systolic volume index (LVESVi, 95 ±â€¯51 vs 74 ±â€¯39 ml/m2, p = .07), and were more frequently anti-coagulated (96% vs 72%, p = .008) despite similar history of atrial fibrillation (54% vs 51%, p = .83). At 6 months, LVEP significantly improved LV ejection fraction (2.3 ±â€¯7.5 and 8.6 ±â€¯10.0%), New York Heart Association Class (0.4 ±â€¯0.9 and 0.7 ±â€¯0.8), LVESVi (9 ±â€¯16 and 18 ±â€¯43 ml/m2), and six-minute walk test (56 ±â€¯73 and 54 ±â€¯92 m) in prior non-responders and failed CS implants, relative to baseline (all p < .05), respectively. LVESVi reduction ≥15% was seen in 47% of the prior non-responder patients and 57% of failed CS patients. CONCLUSION: These data suggest that a sizable proportion of CRT non-responders can improve by LVEP, though to a lesser extent than failed CS implants. Clinical trial registration-URL: http://www.clinicaltrials.gov. Unique identifier: NCT01277783.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/tendências , Terapia de Ressincronização Cardíaca/tendências , Falha de Equipamento , Insuficiência Cardíaca/terapia , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/terapia , Idoso , Terapia de Ressincronização Cardíaca/normas , Dispositivos de Terapia de Ressincronização Cardíaca/normas , Estudos de Coortes , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia
20.
Heart Rhythm ; 15(6): 870-876, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29288035

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) is an effective treatment of heart failure (HF), but is limited by a substantial proportion of nonresponders. We hypothesized that adding a second left ventricular (LV) lead to deliver a triple-site CRT (V3 CRT) may improve clinical status of CRT nonresponders. OBJECTIVE: We assessed the feasibility and safety of adding a second LV lead to CRT nonresponders and its clinical impact. METHODS: Eighty-four recipients of a CRT system and considered as nonresponders as per clinical composite score (CCS) were enrolled in this multicenter study. They were randomized to the V3 arm (implantation of an additional LV lead; n = 43) or control arm (no change; n = 41). Implant success rate, incidence of severe adverse events, CCS, and secondary clinical and echocardiographic end points were evaluated at 12 and 24 months. RESULTS: Positioning of a second LV lead was successful at first (40 of 44 - 90.9%) or second (4 of 44 - 9.09%) attempt. The perioperative complication rate (infection, system explant, pneumothorax, and hematoma) was high (procedures or system-related complications for 9 patients- 20.4%). After 24 months, 35 systems (79.5%) were working properly. The multinomial logistic regression model showed that V3 treatment had no significant influence (P = .27) on the CCS, number of HF hospitalizations, time to first HF hospitalization, New York Heart Association class, and LV ejection fraction at 12 and 24 months. CONCLUSION: Although addition of a second LV lead in CRT nonresponders is feasible with a high success rate, this approach is associated with a significant rate of severe adverse events and does not provide significant long-term clinical benefits (ClinicalTrials.gov Identifier No. NCT01059175).


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia , Eletrodos Implantados , Insuficiência Cardíaca/terapia , Frequência Cardíaca/fisiologia , Ventrículos do Coração/fisiopatologia , Inquéritos e Questionários , Idoso , Ecocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento , Disfunção Ventricular Esquerda , Função Ventricular Esquerda/fisiologia
SELEÇÃO DE REFERÊNCIAS